key: cord-0981942-hfg3oq8f authors: Basu, Sonali; Kim, Esther J.; Sharron, Matthew P.; Austin, Ashley; Pollack, Murray M.; Harahsheh, Ashraf S.; Dham, Niti title: Strain Echocardiography and Myocardial Dysfunction in Critically Ill Children With Multisystem Inflammatory Syndrome Unrecognized by Conventional Echocardiography: A Retrospective Cohort Analysis date: 2021-10-12 journal: Pediatr Crit Care Med DOI: 10.1097/pcc.0000000000002850 sha: b608c164b98b16f55279deead3bc5f6754e552f3 doc_id: 981942 cord_uid: hfg3oq8f Multisystem inflammatory syndrome in children is a newly defined complication of severe acute respiratory syndrome coronavirus 2 infection that can result in cardiogenic shock in the pediatric population. Early detection of cardiac dysfunction is imperative in directing therapy and identifying patients at highest risk for deterioration. This study compares the strengths of conventional and strain echocardiography in identifying cardiac dysfunction in critically ill children with multisystem inflammatory syndrome in children and their association with ICU therapeutic needs and clinical outcomes. DESIGN: Retrospective, observational cohort study. SETTING: A large, quaternary care PICU. PATIENTS: Sixty-five pediatric patients admitted to the PICU with the diagnosis of multisystem inflammatory syndrome in children from March 2020 to March 2021. INTERVENTIONS: Global longitudinal strain four chamber was measured retrospectively by strain echocardiography and compared with conventional echocardiography. Cardiac dysfunction was defined by left ventricular ejection fraction less than 55% and global longitudinal strain four chamber greater than or equal to –17.2%. Clinical variables examined included cardiac biomarkers, immune therapies, and ICU interventions and outcomes. MEASUREMENTS AND MAIN RESULTS: Twenty-four patients (37%) had abnormal left ventricular ejection fraction and 56 (86%) had abnormal global longitudinal strain four chamber. Between patients with normal and abnormal left ventricular ejection fraction, we failed to identify a difference in cardiac biomarker levels, vasoactive use, respiratory support needs, or ICU length of stay. Global longitudinal strain four chamber was associated with maximum cardiac biomarker levels. Abnormal global longitudinal strain four chamber was associated with greater odds of any vasoactive use (odds ratio, 5.8; 95% CI, 1.3–25.3; z-statistic, 2.3; p = 0.021). The number of days of vasoactive infusion was correlated with global longitudinal strain four chamber (r = 0.400; 95% CI, 2.4–3.9; p < 0.001). Children with abnormal strain had longer ICU length of stay (4.5 d vs 2 d; p = 0.014). CONCLUSIONS: Our findings suggest strain echocardiography can detect abnormalities in cardiac function in multisystem inflammatory syndrome in children patients unrecognized by conventional echocardiography. These abnormalities are associated with increased use of intensive care therapies. Evaluation of these patients with strain echocardiography may better identify those with myocardial dysfunction and need for more intensive therapy. KEY WORDS: cardiac dysfunction; multisystem inflammatory syndrome in children; pediatric intensive care unit; strain echocardiography M ultisystem inflammatory syndrome in children (MIS-C) is defined as a constellation of symptoms including: serious illness requiring hospitalization, an age of less than 21 years, fever, laboratory evidence of inflammation, multisystem (> 2) organ involvement, no plausible alternative diagnosis and evidence of infection with severe acute respiratory syndrome coronavirus 2 based on reverse transcriptase-quantitative polymerase chain reaction, antibody testing, or exposure to persons with coronavirus disease 2019 in the past month (1) . A subset of children with MIS-C develop acute cardiogenic shock with left ventricular dysfunction and clinical symptoms similar to myocarditis requiring admission to the PICU (2, 3) . These patients frequently require critical care interventions including vasoactive infusions and positive pressure ventilation (PPV) as well as steroids, IV immunoglobulins (IVIGs), biologic therapies anticoagulation, and supportive care (1, (4) (5) (6) (7) (8) (9) . Identifying early markers of cardiac dysfunction would be helpful to both direct therapy and identify MIS-C patients at highest risk for deterioration. In the absence of endomyocardial biopsies or cardiac MRI, elevation of serum biomarkers N-terminal brain natriuretic peptide (BNP), and troponin-I have been used to diagnose and quantify myocardial injury, as they correlate with the degree of myocardial inflammation (10) . Echocardiographic findings during the acute phase of MIS-C have shown abnormalities in systolic function, atrioventricular valve regurgitation, and coronary artery abnormalities (11) . Conventional echocardiographic assessment of systolic function uses left ventricular ejection fraction (LVEF); however, it can be limited by loading states (12) . Strain echocardiography (SE) is a validated measure that quantifies displacement of segments of myocardium. It can detect subtle perturbations in left and right ventricular deformation that correlate with stroke volume and other intrinsic measures of cardiac function (12) (13) (14) . SE evaluation of myocardial function in MIS-C patients found that global strain correlated with biochemical measures of myocardial injury (BNP > 500 pg/mL and troponin-I > 0.3 ng/mL) (10) . In non-MIS-C children with myocarditis and sepsis, measures of myocardial strain have been sensitive indicators for systolic dysfunction (13) (14) (15) (16) . The association between echocardiographic parameters (SE and LVEF) and ICU severity of illness markers in critically ill children with MIS-C has not been assessed. Our objective was to compare SE and LVEF (as markers of systolic function) in critically ill children with MIS-C and correlate them with biomarker evidence of cardiac dysfunction, ICU therapeutic needs, and clinical outcomes. This was a retrospective study in a large urban academic quaternary care freestanding children's hospital in Washington, DC. The Institutional Review Board at Children's National Hospital approved this study (Protocol 00014477). All pediatric patients (< 21 yr) admitted to the PICU with the diagnosis of MIS-C from March 2020 to March 2021 were reviewed. Confirmation of each diagnosis was done by a multidisciplinary task force and only those patients with confirmed MIS-C were included in our cohort. Demographic information was obtained on each patient including age, gender, race, and ethnicity. Presence of underlying chronic medical conditions, baseline functional status score measured by the Functional Status Scale (FSS) score and initial location of admission (inpatient floor or PICU) were recorded for each patient (17) . A multidisciplinary team developed diagnostic and treatment protocols to identify and treat these patients. As a part of the clinical protocol, patients received echocardiograms to diagnose cardiovascular dysfunction and/or acquired alterations in coronary arteries, a panel of inflammatory markers to determine the effect of immunological activation, and laboratory analyses to determine end-organ dysfunction and involvement. The clinical protocol for confirmed cases included supportive care, IVIG, immune modulation, and empiric anticoagulation. Treating clinicians were not blinded to biomarkers or conventional echocardiography findings. The first echocardiogram obtained during the index hospitalization for each patient was used for the analyses. The echocardiograms were performed on either a e147 Phillips (Andover, MA) or GE (Chicago, IL) vendor machine. Standard protocol was followed for each echocardiogram study, and each was read by a pediatric cardiologist. Conventional echocardiographic measurements were made in accordance with American Society of Echocardiography guidelines, including LVEF by modified Simpson's biplane method (18) . SE was performed retrospectively on each echocardiogram by an experienced sonographer blinded to clinical parameters and reviewed by an attending pediatric cardiologist. SE was done on the TomTec (Chicago, IL) vendor platform. SE measurements were not available to clinicians at the bedside and therefore did not influence clinical management of the patients. Global longitudinal strain (GLS 4ch ) was measured on the apical four-chamber view. GLS measurements with SE are feasible in patients with sufficient image quality and have good inter-and intra-observer reproducibility comparable with that of LVEF measurements with conventional echocardiography. SE can be conducted in real-time on standard echocardiography machines or retrospectively with vendor nonspecific post-processing software (19) . Patients were excluded if both LVEF and GLS 4ch were not able to be measured on the first echocardiogram. We defined preserved or normal LVEF as 55% or greater (20) . By convention, GLS 4ch is reported as a negative percentage, representing an averaged percent change of individual segments of myocardium. A GLS 4CH value more negative than -17.2% is consistent with preserved or normal global longitudinal strain (19, 21) . Presence of pericardial effusion was noted on the first echocardiogram and classified as none, trivial, mild, moderate, or significant. The clinical variables included serum biomarkers of cardiac dysfunction and ICU therapies. Serum biomarkers included N-terminal BNP (in pg/mL) and troponin-I (ng/mL) levels. For each biomarker, we reported the level obtained within 24 hours of admission and maximum level during the hospitalization. ICU therapies included vasoactive infusions and PPV. Vasoactive infusions included epinephrine, norepinephrine, vasopressin, and milrinone. Duration of vasoactive infusions in days and maximum Vasoactive-Inotropic Score (VIS) were recorded for each patient (22) . PPV included use and days of any noninvasive positive pressure ventilation (NIPPV) or invasive mechanical ventilation (MV). For patients requiring endotracheal intubation and MV, findings of chest radiograph after intubation were reviewed for presence of infiltrates, atelectasis, pleural effusion, and/or pulmonary edema. Other outcomes included ICU and hospital length of stay (LOS) and hospital survival. Statistical analysis was performed with Wizard Pro, Version 1.9.48 (Evan Miller, Boston, MA; https:// www.wizardmac.com). Binary and categorial data were expressed as absolute numbers and percentages. Continuous data were summarized by medians and interquartile ranges (25-75th percentiles). chi-square or Mann-Whitney U tests were used to compare proportions of binary or continuous outcomes between normal and abnormal LVEF and SE subgroups. Correlations were assessed using Pearson correlation. Odds ratios were calculated to compare strength of associations. A probability value of less than 0.05 was treated as significant in this analysis. There were 82 children with a confirmed diagnosis of MIS-C admitted to the PICU between March 2020 and March 2021. There were 65 patients with LVEF and GLS 4ch measurements on their first echocardiogram (Fig. 1 ). Patients were a median age of 8.5 years (interquartile range [IQR], 4.2-13.4 yr), 36 (55%) were male, 2 (3%) had chronic medical conditions, and only one had an abnormal baseline FSS. There was a predominance of Black (49%) and Hispanic/Latino patients (43%). The majority (n = 46; 71%) were admitted directly to the ICU and 19 (29%) were admitted to non-ICU locations and subsequently transferred to the ICU. Median time to first echocardiogram was 17 hours (IQR, 8-28 hr) from hospital admission. Table 1 shows measurements of cardiac function and cardiac biomarkers. Median LVEF for all patients was 58% (IQR, 49.7-62.1%). Abnormal LVEF was seen in 24 of 65 patients (37%) with a median LVEF of 48.1% (IQR, 42.9-50.4%), consistent with mild dysfunction. Only one patient in our cohort had a LVEF consistent with moderate dysfunction (< 40%). Pericardial effusions were found in 19 of 65 patients (29%); however, of these, 17 (89%) were trivial and 2 (11%) were mild. Abnormal strain was seen in 56 of 65 patients (86%). Of the 41 patients with normal LVEF, 32 (78%) had abnormal strain. All patients with abnormal LVEF had abnormal strain. There was a significant correlation of GLS 4ch with LVEF (r = -0.535; 95% CI, -14.4 to -12.4; p < 0.001). All patients had increased maximum BNP concentrations (> 500 pg/mL) with a median value of 18,480 pg/mL and 38 (58%) patients had increased troponin-I levels (> 0.3 ng/mL) with a median value of 0.37 ng/mL. There was no difference in admission or maximum BNP or troponin levels between patients with normal and abnormal LVEF. Admission troponin was higher in those with abnormal strain (0.12 vs 0.03; p = 0.032). Both maximum BNP and troponin values were higher in patients with abnormal GLS 4ch compared with those with normal GLS 4ch (19, Table 2 shows ICU therapies and clinical outcomes for our patients based on LVEF and SE. Of the patients requiring endotracheal intubation, post-intubation films showed pleural effusion in only one of 13 patients, pulmonary edema in eight of 13 patients, and atelectasis in four of 13 patients. At the time of their first echocardiogram, 8 (12%) of our patients were receiving MV and 32 (49%) were receiving vasoactive infusions, with a median VIS of 7.5. Of the 32 patients on vasoactives at the time of the echocardiogram, median LVEF was 56.8% (IQR, 50.4-61.6%) and median strain was -12.4% (IQR, -14.7% to -10%). There were 12 of 32 patients (37%) who had abnormal LVEF, whereas 30 of 32 patients (94%) had abnormal GLS 4ch . We did not identify a difference in use or duration of vasoactives, use of PPV, or use or duration of NIPPV or MV between patients with normal and abnormal LVEF. Abnormal GLS 4ch was associated with greater odds of any vasoactive use (odds ratio, 5.8; 95% CI, 1.3-25.3; z-statistic, 2.3; p = 0.021). The number of days of vasoactive infusion was correlated with GLS 4ch (r = 0.400; 95% CI, 2.4-3.9; p < 0.001). We did not identify a difference in ICU or hospital LOS between patients with normal or abnormal LVEF. However, patients with abnormal GLS 4ch had a longer ICU LOS (4.5 vs 2 d; p = 0.014) than those with normal GLS 4ch . GLS 4ch was correlated with ICU LOS (r = 0.271; 95% CI, 3.8-6.6; p = 0.029). All patients survived to hospital discharge. In this single-center retrospective study, we compared cardiac dysfunction in critically ill MIS-C patients assessed by conventional and SE and examined the association of echocardiographic findings with cardiac biomarkers and clinical outcomes. Our findings suggest SE can detect abnormalities in cardiac function that are unrecognized by conventional echocardiography and are associated with increased use of intensive care therapies. Published case series have reported abnormal LVEFs in 34-80% of MIS-C patients, with median LVEF values ranging from 46% to 60% (1, 8, 10, 11, (23) (24) (25) . This mild degree of dysfunction is similar to our study, where the median LVEF in our abnormal EF group was 48.1% and all patients was 61.4%. While LVEF is the most commonly used metric to assess for cardiac dysfunction, there are several important SE is an angle-independent, direct measurement of myocardial tissue motion and deformation and is relatively independent of loading conditions, allowing it to be a useful measure in clinical scenarios where fluid resuscitation and vasoactive infusions are commonly employed (15, 26) . Global longitudinal strain has been studied extensively as a method to detect abnormal myocardial mechanics and has superior prognostic value to LVEF in predicting major adverse cardiac events and mortality (27) (28) (29) (30) (31) (32) . While we found a higher prevalence of abnormal strain in patients with normal LVEF than other studies, the general observations of systolic dysfunction by SE in MIS-C patients with preserved LVEF are consistent with our results (10, 11, 23, 24, 33) . The high prevalence of impaired strain in our cohort (86%) may arise from the clinical status of our patients being in the ICU with physiologic derangements consistent with more disease severity. Several studies have shown significant correlations of multiple metrics of strain, including global longitudinal strain, with both BNP and troponin-I (10, 24, 33) . Although there is sparse histologic data describing the etiology of cardiac dysfunction in MIS-C, myocardial inflammation related to the systemic inflammation has been a proposed mechanism (24) . This inflammation has been seen on endocardial biopsy and cardiac MRI in select case reports. However, n-terminal BNP and troponin-I levels have more widespread use (2, 7, 8, 10, 11, 5) . While nearly all our patients showed elevation in biomarkers, there was no difference in BNP or troponin-I between patients with normal and abnormal LVEF, while patients with abnormal strain had maximum levels two-to four-fold as high. These associations were not seen with admission BNP levels, suggesting strain may have utility in early identification of myocardial inflammation in patients with normal LVEF. We found an association of strain and several ICU outcomes, including intensity of vasoactive use and ICU LOS that were not observed with LVEF. In a study with critically ill septic children, a correlation between higher VIS and worsening left ventricular longitudinal strain was been seen and thought to be the result from poor intrinsic cardiac function leading to increased need for inotropes (13) . These findings support strain as a sensitive and clinically relevant indicator of cardiac dysfunction that is associated with severe illness and requirement of cardiovascular and respiratory support. Similar relationships have been seen with strain and various clinical metrics; however, in a population less critically ill as ours (24) . The limitations of this study include its population from a single center, retrospective design, lack of uniformity of timing of echocardiogram with clinical interventions, and 17 of 82 patients (21%) excluded due to inadequate imaging for one of the imaging measures. We also only analyzed only one SE metric of systolic strain (GLS 4ch ). Additional measurements, including more specific assessment of diastolic dysfunction may yield additional associations with clinical outcomes. There were also variable amounts of volume resuscitation, PPV support, and vasoactive administration at the time of the imaging studies, which may have had disproportional effects on LVEF and strain. Abnormal myocardial strain is common in children with MIS-C admitted to the PICU and may be indicative of myocardial dysfunction in the setting of normal LVEF. Patients with abnormal strain required more intensive therapies. Real-time SE may identify MIS-C patients at risk for more aggressive interventions, while normal strain measurements may identify children with milder symptoms and less aggressive course of disease. Overcoming COVID-19 Investigators; CDC COVID-19 Response Team: Multisystem inflammatory syndrome in U.S. children and adolescents Acute heart failure in multisystem inflammatory syndrome in children in the context of global SARS-CoV-2 pandemic Centers of Disease Control and Prevention: Multisystem Inflammatory Syndrome in Children (MIS-C) Associated With Coronavirus Disese 2019 (COVID-19). 2020. Available at Intensive care admissions of children with paediatric inflammatory multisystem syndrome temporally associated with SARS-CoV-2 (PIMS-TS) in the UK: A multicentre observational study New York State and Centers for Disease Control and Prevention Multisystem Inflammatory Syndrome in Children Investigation Team: Multisystem inflammatory syndrome in children in New York State COVID-19-associated multisystem inflammatory syndrome in children -United States Clinical characteristics of 58 children with a pediatric inflammatory multisystem syndrome temporally associated with SARS-CoV-2 Multisystem inflammatory syndrome in children: A systematic review of the International Kawasaki Disease Registry: Management of multisystem inflammatory syndrome in children associated with COVID-19: A survey from the International Kawasaki Disease Registry Echocardiographic findings in pediatric multisystem inflammatory syndrome associated with COVID-19 in the United States Rapid Response Team*: Acute cardiovascular manifestations in 286 children with multisystem inflammatory syndrome associated with COVID-19 infection in Europe Myocardial function defined by strain rate and strain during alterations in inotropic states and heart rate Cardiac dysfunction identified by strain echocardiography is associated with illness severity in pediatric sepsis Altered left ventricular tissue velocities, deformation and twist in children and young adults with acute myocarditis and normal ejection fraction Strain echocardiography parameters correlate with disease severity in children and infants with sepsis Two-dimensional speckle tracking imaging detects impaired myocardial performance in children with septic shock, not recognized by conventional echocardiography Eunice Kennedy Shriver National Institute of Child Health and Human Development Collaborative Pediatric Critical Care Research Network: Pediatric intensive care outcomes: Development of new morbidities during pediatric critical care Recommendations for cardiac chamber quantification by echocardiography in adults: An update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging Head-to-head comparison of global longitudinal strain measurements among nine different vendors: The EACVI/ASE Inter-Vendor Comparison Study Pediatric Heart Network Investigators: Comparison of echocardiographic and cardiac magnetic resonance imaging measurements of functional single ventricular volumes, mass, and ejection fraction (from the Pediatric Heart Network Fontan Cross-Sectional Study) Research to practice: Assessment of left ventricular global longitudinal strain for surveillance of cancer chemotherapeutic-related cardiac dysfunction Validation of the vasoactive-inotropic score in pediatric sepsis Multimodality cardiac evaluation in children and young adults with multisystem inflammation associated with COVID-19 Detailed assessment of left ventricular function in multisystem inflammatory syndrome in children using strain analysis Multisystem inflammatory syndrome in children: Cardiac biomarker profiles and echocardiographic findings in the acute and recovery phases Assessment of left ventricular function by echocardiography: The case for routinely adding global longitudinal strain to ejection fraction Global longitudinal strain and cardiac events in patients with immune checkpoint inhibitor-related myocarditis Outcome prediction in sepsis: Speckle tracking echocardiography based assessment of myocardial function Role of tissue Doppler and strain echocardiography in current clinical practice Prediction of all-cause mortality from global longitudinal speckle strain: Comparison with ejection fraction and wall motion scoring Strain imaging in echocardiography: Methods and clinical applications Prognostic implications of global LV dysfunction: A systematic review and meta-analysis of global longitudinal strain and ejection fraction Left ventricular global longitudinal strain in identifying subclinical myocardial dysfunction among patients hospitalized with COVID-19