key: cord-0978785-hx7hxyco authors: Wang, Jianxin; Drelich, Adam J.; Hopkins, Caroline M.; Mecozzi, Sandro; Li, Lingjun; Kwon, Glen; Hong, Seungpyo title: Gold nanoparticles in virus detection: Recent advances and potential considerations for SARS‐CoV‐2 testing development date: 2021-09-08 journal: Wiley Interdiscip Rev Nanomed Nanobiotechnol DOI: 10.1002/wnan.1754 sha: d4d4ea031c968d1e30a1cf4a0823716e55314096 doc_id: 978785 cord_uid: hx7hxyco Viruses are infectious agents that pose significant threats to plants, animals, and humans. The current coronavirus disease 2019 pandemic, which is caused by severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2), has spread globally and resulted in over 2 million deaths and immeasurable financial losses. Rapid and sensitive virus diagnostics become crucially important in controlling the spread of a pandemic before effective treatment and vaccines are available. Gold nanoparticle (AuNP)‐based testing holds great potential for this urgent unmet biomedical need. In this review, we describe the most recent advances in AuNP‐based viral detection applications. In addition, we discuss considerations for the design of AuNP‐based SARS‐CoV‐2 testings. Finally, we highlight and propose important parameters to consider for the future development of effective AuNP‐based testings that would be critical for not only this COVID‐19 pandemic, but also potential future outbreaks. This article is categorized under: Diagnostic Tools > Biosensing. Diagnostic Tools > In Vitro Nanoparticle‐Based Sensing. Roser, 2020), the impact of virus infection on patients and even healthy individuals is much more significant than the number of deaths can tell. Importantly, viruses have been the only cause of major pandemics since the 1918 H1N1 flu pandemic (CDC website. https://www.cdc.gov/flu/pandemic-resources/basics/past-pandemics.html). The main reasons behind this are manifold, including the virus's highly contagious nature, evolving capability, and the absence of efficient diagnostics, therapeutics, and vaccines. Currently, the ongoing coronavirus disease 2019 pandemic, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has spread to over 210 countries and territories, leaving over 100 million people infected, over 2 million people dead and millions jobless (Johns Hopkins website. https://coronavirus.jhu.edu; United Nations website. https://news. un.org/en/story/2020/04/1061322). Rapid and accurate viral detection is critical for infectious status assessment, decision making, and subsequent control of viral dissemination. For such application, highly sensitive and reliable diagnosis tools, such as in vitro diagnostic devices (IVDs), are required and are of great scientific and clinical interest due to their ease of use, low cost, and high throughput. Among IVDs, gold nanoparticle (AuNP)-based IVDs represent a promising approach because of the unique physical and optical properties of AuNPs, including localized surface plasmon resonance (LSPR), fluorescence resonance energy transfer (FRET), surface-enhanced Raman scattering (SERS), nonlinear optical properties, and the quantized charging effect (Zhou et al., 2015) . Over the past two decades, a significant progress has been made on AuNP-based detection for viruses as well as other pathogens and diseases, which is evidenced by the dramatically increased number of publications found in PubMed since the year 2001 ( Figure 1 ). In this review, we summarize recent AuNP-based virus detection applications based on the amplification and detection strategies used. Our goal in this review is to understand the status quo of AuNP-based assays for virus detection applications and provide considerations for the design of AuNP-based COVID-19 diagnostics and insights into trending parameters of IVDs so that researchers can incorporate the knowledge and develop AuNP-based assays more efficiently for combating COVID-19, as well as for other infectious diseases in the future. In the following sections, we will mainly discuss the recent advances in AuNP-based virus detection since 2016, as earlier studies have been well summarized elsewhere (Draz & Shafiee, 2018) . We have divided the detection assays based on the amplification strategy involved, whether it is through a more traditional approach or a combination of different amplification strategies to maximize the limit of detection (LOD) (Figure 2 ). An extensive overview of recent applications in AuNP-based virus detection is shown in Table 1 . The lateral-flow assay (LFA) is probably the most commonly used point-of-care (POC) diagnostic format of AuNP-based IVD. For example, over-the-counter (OTC) pregnancy test strips are widely used from home due to ease of use, short testing time, and low cost. For virus detection, polymerase chain reaction (PCR) is typically used due to its high sensitivity and specificity. However, it often requires specialized equipment and reagents, along with trained personnel to operate. In contrast, paper-based LFAs require no expensive equipment and can be performed with simple steps and return results within minutes, making them useful tools in field applications and remote and low-resource settings. In a traditional LFA, antibodies are used as capture or detection molecules. This type of LFA is called a lateral-flow immunochromatographic assay (LFIA). Generally, LFIAs have two formats: sandwich format and competitive format. For analytes with more than one epitope (e.g., viruses), the sandwich format LFIA (Figure 3a ) is commonly used. In this format, antibodies against the target analyte are dispensed at the test line. When target analytes are present in the sample, analytes bind to antibody-NP conjugates first, followed by secondary binding to antibodies pre-immobilized on the test surface, which forms a sandwich complex and displays a color indicating a positive result. When there is no target analyte present in the sample, the antibody-NP conjugates would not bind to the test line and no color changes would be displayed. For analytes with lower molecular weights and a single antigenic determinant, which cannot bind two antibodies simultaneously, the competitive format LFIA (Figure 3b ) is applicable. In this case, target antigens are dispensed at the test line. When the target analytes are present in the sample, the analytes bind to the antibody-NP conjugates and leave the test line blank, indicating a positive result. When target analytes are absent, in contrast, the antibody-NP conjugates bind to the antigens pre-immobilized at the test line, which displays a visible test line indicating a negative result. For AuNP-based LFIAs, antibodies are typically conjugated directly to AuNPs. In a recent study, Chavan et al. developed a protein nanoparticle as a new scaffold by genetically modifying human apoferritin heavy chain protein with a 6ÂHis and protein-G tag, enabling direct binding of 5 nm Ni-NTA-nanogold and anti-infectious pancreatic necrosis virus (IPNV) antibodies, respectively. This approach effectively avoids bioconjugation through chemical F I G U R E 2 Schematic illustration of AuNP-based virus detection approaches discussed in this article linkers ( Figure 4 ). The efficiency of this nanoprobe was tested for IPNV detection in an LFIA format, in which case a linear range of 10 1 -10 3 TCID 50 (median tissue culture infectious dose)/ml with a LOD of 0.88 TCID 50 /ml was obtained, which is equivalent to c.a. 0.62 PFUs/ml (ATCC website. https://www.atcc.org/support/faqs/48802/ Converting+TCID50+to+plaque+forming+units+PFU-124.aspx). Furthermore, the authors demonstrated that this nanoprobe exhibited excellent sensitivity towards IPNV, in contrast to the commercial paper-based system, and holds promise to be adapted for the detection of other biomarkers (Chayan et al., 2019) . Although antibodies have been the commonly employed detection molecules in LFA-based diagnostics, they face some challenges. For example, the choice of targets has been limited to proteins on the viral surface. Moreover, cross activities may be a concern among viruses with close homology. Nucleic acid-based detection holds great promise in addressing this. In a recent study, Gao et al. engineered a nanoprobe consisting of a 15 nm AuNP labeled with two DNA oligos: (i) one as a detection DNA oligo, which is complementary to the target DNA and (ii) an additional biotinylated DNA oligo as a streptavidin assembly site for three-dimensional DNA-AuNPs network amplification ( Figure 5) . A 30-base nucleotide sequence characteristic of the hepatitis B virus (targHBV) was selected as a model to test the performance of this nanoprobe. The authors reported a linear range of target concentration from 0.1 pM to 250 nM with a LOD of 0.01 pM, which is four orders of magnitude more sensitive than traditional sandwich assays without network amplification, although a real sample of long DNA with secondary structures will need to be investigated in their future work (Gao et al., 2017) . LFAs provide a simple and fast diagnostic tool for both clinical professionals and the public through OTC devices. The global LFA market has made solid growth over the past few decades and is anticipated to reach over $9 billion by 2024 (Lateral Flow Assay Market. https://www.marketdataforecast.com/market-reports/lateral-flow-assay-market). Nevertheless, more efforts needed to be devoted in order for LFAs to meet new requirements and challenges. First, sensitivity. Clinical professionals have a persisting need for better sensitivity so viruses, as well as other biomarkers, can be detected at earlier stages of disease progression. Second, digitalization. The digitalization of LFAs can offer many benefits. One promising approach is to integrate LFAs into mobile devices with cameras and image analysis software, which could help patients interpret LFA results and share information with healthcare providers. Third, multiplexing. Multiplexing endows LFAs the ability to analyze multiple analytes in a single sample, which can reduce the number and volume of samples required and reduce test times and costs, but provide more information to healthcare providers. Fourth, more efforts are needed for the development of LFAs relying on nucleic acid and other capture molecules instead of antibodies, for nucleic acid-based diagnosis. In light of the COVID-19 pandemic, developing nucleic acid or antigen-based LFAs will enable direct detection of SARS-CoV-2. Another characteristic of AuNPs that has been well utilized in biosensor development is LSPR-induced fluorescence quenching or enhancement, including FRET (Zhou et al., 2015) and nanoparticle surface energy transfer (Griffin et al., 2009) . Recently, a luminescence resonance energy transfer biosensor specific for the Ebola virus was demonstrated by Tsang and coworkers. This sensor consisted of two types of NPs: a 980-nm absorbing BaGdF5:Yb/Er upconversion nanoparticle (UCNP) conjugated with oligonucleotide probe and an AuNP linked with Ebola virus oligonucleotide. For clinical samples, viral RNA was extracted and conjugated to carboxylated AuNPs via EDC chemistry. When the target virus was present, AuNP bound to UCNP through DNA/DNA or DNA/RNA hybridization caused the quenching effect to take place. The AuNP-bound UCNP through DNA/DNA or DNA/RNA hybridization and the quenching effect took place. As a result, the intensity of the main emission peaks (523, 546, and 654 nm) of UCNP decreased in F I G U R E 6 (a) (i) Comparison of the homogeneous and heterogeneous assays for Ebola virus oligo detection; (ii) UC emission spectra of BaGdF5:Yb/Er-probe UCNPs with various concentrations of Ebola virus oligo target in the homogeneous assay; (iii) UC emission spectra of BaGdF5:Yb/Er-probe UCNPs with various concentration of Ebola virus oligo target in the heterogeneous assay with NAAO membrane. (b) Schematic diagram of Ebola target oligo detection based on LRET biosensor with energy transfer from UCNPs to AuNPs on NAAO membrane. Reprinted with permission from Tsang et al. (2016) . American Chemical Society proportion to the concentration of virus oligos. Two formats, homogeneous and heterogeneous, were developed. The homogeneous format simply mixed two types of NPs in a colloidal solution. Subsequently, green upconversion luminescence emission was observed with the naked eye as a result of 980 nm laser excitation. For the heterogeneous format, UCNPs were anchored on a nanoporous alumina (NAAO) membrane ( Figure 6 ). Compared to the F I G U R E 7 Schematic representation of the detection principle for the influenza virus using the LSPR-induced fluorescence nanobiosensor. Reprinted with permission from Takemura et al. (2017) . Elsevier B.V F I G U R E 8 Schematic diagram for the preparation of CdZnSeS/ZnSeS QD-peptide-AuNP nanocomposite and its detecting mechanism towards the influenza virus. AuNPs and QDs are conjugated by peptide linkers in this current work. Reprinted with permission from Nasrin et al. (2020) . Elsevier B.V homogeneous assay, the LOD of the heterogeneous assay is significantly improved from 7 pM to 300 fM (Tsang et al., 2016) . The short reaction time and easy operation of the nanoprobe are advantages of this assay compared to other existing detection methods, such as real-time PCR (RT-PCR) and enzyme-linked immunosorbent assay (ELISA). Takemura et al. developed a fluorescence-enhancement influenza virus immunosensor using anti-NA Abconjugated AuNPs in conjunction with anti-HA Ab-conjugated QDs. As shown in Figure 7 , the simultaneous binding of AuNP and QD to the same virus virion brought AuNPs in close proximity to QDs and triggered an LSPR-induced fluorescence enhancement, which in turn provided a quantitative linear concentration range of 10-100 pg/ml and LOD down to 0.03 pg/ml for H1N1 detection . In a recent study by Nasrin and coworkers, an AuNP-based H1N1 immunosensor was developed based on the exquisite manipulation of the distance between QD and AuNP before and after virus binding. The study clearly showed a distancedependent LSPR influence, from fluorescence quenching when AuNP and QD were very close together, to a continuous fluorescence enhancement when the distance was above a threshold. In the sensor, an 18 amino acid-based peptide linker was used to tether AuNP and QD to each end and two antibodies were anchored in the middle for virus binding ( Figure 8 ). When no virus was present, AuNP and QD were in close proximity and the fluorescence intensity of QD was low. When the virus was present and bound to the antibodies, the steric hindrance helped to lift fluorescence in proportion to a virus concentration range of 10 À14 -10 À9 g/ml. Impressively, an ultra-low LOD of 17.02 fg/ml was achieved (Nasrin et al., 2020) . A traditional AuNP-based fluorescent assay consists of fluorophores, and AuNPs often as fluorescence quenchers, featuring high sensitivity, biocompatibility, easy and tunable AuNP synthesis, and unique distance-dependent fluorescence quenching/enhancement properties of AuNPs. However, precise control of the distance between AuNP and fluorophore remains a challenge. Alternatively, assays using fluorescent AuNPs (e.g., gold nanoclusters), which function as fluorophores by themselves, represent another type of AuNP-based fluorescent assays. Like all fluorescent assays, background fluorescent signals, particularly for complex clinical samples, often cause an issue. This issue can be potentially addressed using NIR dyes or UCNPs in combination with two-photon optics. LSPR of AuNPs is largely driven by the light-induced excitation of conduction electrons. LSPR is a characteristic optical property of AuNPs, which produces strong optical absorption or scattering at characteristic frequencies in the visible to NIR region (Wei et al., 2013) . AuNPs are well known as LSPR sensors due to their sensitive spectral response to the local environment of the nanoparticle surface, and many AuNP-based LSPR sensors have been reported in virus detection applications recently Lee et al., 2019; Luo et al., 2018; Qiu et al., 2020; Shawky et al., 2017) . Lee et al. engineered an H5N1 aptasensor using hollow Au spike-like NPs functionalized with aptamers specific for F I G U R E 9 Schematic image of the fabricated AIV detection biosensor based on the LSPR method. Reprinted with permission from Lee et al. (2019) . Elsevier B.V hemagglutinin (HA) protein (Figure 9). A detection limit of 1 pM was obtained with a linear concentration range of 1 pM to 10 nM HA spiked in chick serum . In addition, Shawky et al. (2017) developed an AuNP-based nucleic acid sensor for HCV detection from human serum containing isolated HCV RNA and obtained a LOD of 4.57 IU/μl. Another study by Kim et al. (2018) showed a LOD of 100 fg/ml for HBV detection using an HBV surface antigen (HBsAg) Ab-coated AuNP as the probe and LSPR peak shift as the readout. The advantage of AuNP-based LSPR assays is quite obvious: the positives are often interpretable by the naked eye, although quantitative analysis will rely on a simple UV-Vis spectrometer or plate reader. However, precautions are needed to prevent pitfalls of false positives especially in complex samples, since AuNPs tend to aggregate when high ionic strength and high levels of biothiols are present, as most AuNPs are stabilized by ligands via a thiol linkage. Moreover, a few challenges, such as sensitivity, selectivity in complex biological solutions, and adaptation of sensing elements for POC diagnostic devices need to be addressed before a wider translation of LSPR-based assays into clinical practice (Unser et al., 2015) . SERS spectroscopy has emerged as a next-generation biosensor technology that affords rapidity, high sensitivity, multiplexing and can be miniaturized for POC applications in conjunction with portable Raman readers (Neng et al., 2013) . SERS sensors usually consist of Raman reporters adsorbed to noble metal (i.e., Ag or Au) nanoparticles or roughened noble metal surfaces, which produce an electromagnetic field upon laser excitation because of their LSPR property. Strong inelastic light scattering from Raman reporters can be further magnified and used as a readout for quantitative analyte detection. AuNPs have been employed in SERS for decades and many groups have developed AuNP-based SERS assays for virus detection in the past (Kami nska et F I G U R E 1 0 Schematic illustration of (a) Zika-mAb-SERS nanoprobe assembly: Au-SHIN ($100 nm Au core + 4 nm silica shell thickness); Au-SHIN + NB Raman reporter layer; Au-SHIN + NB Raman reporter layer + final $10 nm silica shell (SERS nanoprobe); conjugation onto Zika NS1 monoclonal antibodies (Zika-mAb). (b) SERS immunoassay platform for detecting different concentrations of Zika NS1. The platform is irradiated with a 633 nm laser line and the SERRS signal from NB molecules, located in close proximity to gold nanoparticles ($4 nm), is recorded by area mapping. Brighter spots indicate the higher intensity of the NB band at 593 cm À1 . Reprinted with permission from Camacho et al. (2018) . American Chemical Society Recently, Camacho et al. (2018) developed SERS probes using gold shell-isolated nanoparticles (Au-SHIN), which consists of 100 nm Au nanoparticles and a 4 nm silica shell as the scaffold and Nile Blue (NB) as the Raman reporter. The nanoprobes were wrapped in a final silica shell and functionalized with monoclonal anti-NS1 antibodies for Zika virus (ZIKV) detection. The platform was irradiated with a 633 nm laser line and the surface-enhanced resonance Raman scattering (SERRS) signal from NB molecules, located in close proximity to AuNPs ($4 nm), is recorded by area mappings. Brighter spots indicate the higher intensity of the NB band at 593 cm À1 (Figure 10 ). This method was used to detect NS1 in PBS with a range of 10 ng/ml-50 μg/ml and showed a LOD down to 10 ng/ml. Dengue virus (DENV) is another flavivirus that belongs to the same family of ZIKV. Impressively, no cross-reactivity with DENV NS1 antigens was found, showing a good specificity for this platform. SERS offers many unique advantages over traditional fluorescent techniques, including ultrasensitivity and excellent multiplexing ability, especially insensitivity to photobleaching and quenching, which makes repetitive and long-term measurement possible. Aside from these advantages and established improvements, significant technical challenges remain to be overcome before SERS-based assays can be translated from proof-of-concept studies to clinically available tools. First, reproducibility. SERS signals are very sensitive to many parameters, such as the size and shape of nanoparticles, the distance between nanoparticles, and even the orientation of the "hot spots" to the incident laser. As batch variance is common with nanoparticle synthesis, even fine differences could lead to inconsistent results of SERS assays. Also, drying nanoparticles on a substrate is a common process of many SERS assays. This drying process may lead to nanoparticle aggregation and generate capture-independent SERS signals, which make reproducible SERS measurement more challenging. Second, quantification of SERS signal in complex biological samples might not be straightforward and obtaining a broad linear detection range sometimes could be challenging. Third, the selection of Raman reporters is very critical for SERS-based multiplexing detection. Ideally, Raman reporters used for multiplexing detection should have minimal spectral overlap, which can make deconvolution of each reporter much easier. Therefore, more efforts are needed in developing a larger pool of Raman reporters with high intensity and unique spectrum. Fourth, minimization of Raman reporter fluorescence background through the development of instrumentation or other suppression techniques is needed. Electrochemical biosensors represent another class of popular biosensors besides optical (e.g., colorimetric, fluorescent, chemiluminescent, etc.) biosensors (Table 1) . Electrochemical biosensors often employ gold nanomaterials to enlarge the electrochemically active areas and improve the electron transfer efficiency between electrodes with detection materials, which can help to achieve better performance with ultrahigh sensitivity and stability (Holzinger et al., 2014; Jiang et al., 2018) . Recently, Alizadeh et al. developed an electrochemical-based HepB virus immunosensor. In this sensor, Fe 3 O 4 /antibody (Ab 1 ) magnetic nanoparticles were adsorbed to the electrode by the magnetic field. G-quadruplex DNA/hemin and antibody (Ab 2 ) labeled AuNPs formed a sandwich-structure when target analyte HBsAg was present in the sample, and as HRP mimicking-DNAzyme, triggered methylene blue oxidation (Figure 11a ). The oxidation signal was converted to a square wave voltammetry signal and provided a quantitative measurement of HbsAg with a linear concentration (Alizadeh et al., 2017) . In another study of HepB virus detection, Pei et al. fabricated an electrochemical immunosensor using a carbon electrode coated with a AuNPs-loaded polypyrrole nanosheet (AuNPs/PPy NS), which was further functionalized with specific antibodies for HBsAg capture (Figure 11b ). The HBsAg concentration was converted to a quantitative electric current signal and provided a broader linear concentration range of 0.5-10,000 pg/ml and a similar LOD of 0.166 pg/ml (Pei et al., 2019) . Electrochemical sensors hold the promise of transformative change in clinical practice due to their speed, sensitivity, and selectivity. Although electrochemical assays are very popular in proof-of-concept studies, they still face many challenges to achieve their goal. One drawback is many electrochemical assays rely on metallic or ceramic electrodes, which are relatively expensive. More efforts need to focus on developing alternative electrodes with cheaper materials (e.g., carbon-based electrodes). Another drawback is that many electrochemical assays require a bulky instrument, F I G U R E 1 4 Smartphone lateral flow point-of-care test for Ebola virus IgG detection. (a) Lateral flow strip illustration: serum applied onto the sample pad migrates through the analytical area, and subsequently forms complexes between the labeled gold nanoparticles (AuNPs) and the target analytes. Specifically targeted IgG serum antibodies against single or multiple recombinant Ebola viral proteins then bind to preprinted test lines, forming a visual red-purple line. A control line is used to validate the assay function for the detection of antihuman antibody-gold nanoparticle conjugates. Assay results appear after 15 min. (b) Illustration of the smartphone application (app) interface login window to record patient details; following submission, the analysis window opens; once the red box is aligned between the test and control lines, a tap on the screen provides the strips' analysis; result analysis window, which presents the relative intensity of the test line and determines whether the result is positive or negative based on an evaluated cutoff threshold. The window also provides a summary of patient details and a description of the test taken. Reprinted with permission from Brangel et al. (2018) . American Chemical Society which dramatically reduces its value as a POC tool. Integration with microfluidics is a good way to overcome both cost and portability challenges. Microfluidic systems are an attractive format for POC diagnostics that feature advantages such as portability, faster reaction time, enhanced analytical sensitivity, low reagent and sample consumptions, low cost, high-throughput, easier automation, integration of lab routines in one device (lab-on-a-chip), and so on. AuNPs are attractive for the development of microfluidic diagnostic devices because of their size-dependent colorimetric and fluorescent properties. A study by Chand et al. reported a proof-of-concept microfluidic chip for the electrochemical detection of norovirus. As shown in Figure 12 , screen-printed carbon electrode was modified with a graphene-AuNPs composite, which was further functionalized through streptavidin-biotin binding with aptamer tagged with ferrocene as a redox probe. Using differential pulse voltammetric analysis, a detection limit of 100 pM with a detection range from 100 pM to 3.5 nM for norovirus was obtained (Chand & Neethirajan, 2017) . The testing time of the proposed microfluidic electrochemical aptasensor was less than 35 min, which is faster than conventional ELISA and PCR analysis. With a specific aptamer, sensitivity and specificity can be further enhanced. Later, Xia et al. fabricated a microfluidic sensor with PDMS herringbone structures coated with HA-specific antibodies for H5N2 virus capture. The captured virus was further labeled with Ab-coated Au-Ag core-shell NPs. A detection limit of 2.7 Â 10 4 EID 50 /ml was obtained with visual detection by the naked eye, which was one order of magnitude better than that of conventional fluorescence-based ELISA. The LOD was further improved to 8 Â 10 3 EID 50 /ml with a pair of polarizers and a smartphone for imaging and colorimetric detection ( Figure 13 ). The entire virus capture and detection process could be completed in 1.5 h (Xia et al., 2019) . Microfluidic assays benefit from portability, extremely low sample volume requirement, and hold great promise for high throughput screening, especially in low-resource settings. Miniaturization and automation are critical to the commercial success of microfluidic assays. Several products, such as Filmarray ® , Cobas ® Liat ® , GeneXpert ® , and VerePLEX™ have already been commercialized. With the development of instrumentation in combination with modern technologies such as 3D printing, rapid prototyping becomes easily accessible. It is anticipated that more and more commercial microfluidic devices will become available. Although single amplification-based diagnostics are relatively easy to develop and easy to use, for applications that require an ultra-low LOD, these single amplification-based assays often lack sufficient sensitivity. In this section, we discuss recent advances in AuNP-based virus detection using multi-amplification strategies. As discussed above, LFA is one of the most popular AuNP-based IVD formats. However, traditional LFAs face challenges like not being quantitative, poor sensitivity for some analytes, and so on. Along with the advancement of LFA development, more tools are integrated with traditional LFA strips to help overcome the aforementioned weaknesses, as discussed in detail below. Brangel et al. designed an LFA assay combined with a custom smartphone application (app) for semiquantitative detection of viral hemorrhagic Ebola virus disease IgG antibodies in human serum. Two configurations were developed, one for monoplex detection of IgG against recombinant glycoprotein GP 1-649 , and the other for multiplex detection of either different Ebola species or different IgG antibodies against different viral proteins of the same virus ( Figure 14) . The monoplex platform demonstrated a 200 ng/ml LOD and 100% sensitivity and 98% specificity in a cohort of 90 SUDV survivors and 31 noninfected controls compared to standard whole antigen ELISA. The availability of a POC test to detect antibody immune response in multiplex platforms is especially valuable in remote areas for enhanced vaccine efficiency evaluation, as well as more efficient diagnosis, patient management, and surveillance both during and post outbreaks (Brangel et al., 2018) . Another strategy to improve the sensitivity of AuNP-based LFA is to characterize AuNPs after chromatographic separation using a sensitive analytical technique such as SERS. Fu et al. proposed a SERS-based LFA using Raman reporter-functionalized AuNPs as SERS tags, which were further functionalized with oligonucleotides as detection/ capture molecules, for the quantitative analysis of HIV-1 DNA (Figure 15 ). The authors were able to achieve a LOD of 0.24 pg/ml. In contrast, most commercial LFA products, including those for glucose and pregnancy tests, are limited to biomarkers with high concentrations (at mg/ml or μg/ml levels). Importantly, many portable Raman systems have already been commercialized. It is expected that the integrated SERS-based LFAs can maintain high sensitivity and portability features simultaneously (Fu et al., 2016) . LFIA and lateral flow aptamer assay rely on high-quality antibodies or aptamers for antigen binding and detection. This not only increases the cost and production time, but they also suffer from poor availability and low sensitivity. Many samples from patients only contain very low virus titers. A diagnostic device with high sensitivity means viruses or diseases can be detected very early or at pre-symptomatic phases, which is critical in the dissemination control of an epidemic or pandemic. To obtain high sensitivity for virus detection, especially when nucleic acids become the target analytes, PCR-coupled LFAs have emerged as a powerful tool. Traditional PCRs rely on professionals and expensive PCR cyclers for amplification, which is not practical for resource-limited settings. Excitingly, many isothermal PCRs have been developed over the past few decades, which tremendously reduced the reliance on bulky instruments. Although many studies have applied different isothermal PCR methods for virus detection, including loop-mediated isothermal amplification (LAMP) Chi et al., 2017; Ye et al., 2018) , helicase-dependent amplification (Moura-Melo et al., 2015) , rolling circle amplification (Xing et al., 2013) , and recombinase polymerase amplification (RPA) , very few were integrated with LFAs. In a recent study, Ivanov et al. (2020) integrated RPA into an LFA for potato virus X (PVX) detection and obtained a LOD of 0.14 ng PVX per gram of potato leaves, which was 260 times more sensitive than a conventional lateral flow F I G U R E 1 7 Steps of the developed label-free in situ isothermal RPA amplification/detection biosensor on primer-modified SPCE-AuNP electrodes employing impedance for the determination of CTV-related nucleic acid. Reprinted with permission from Khater and Escosura-Muniz (2019) . American Chemical Society T A B L E 2 FDA-approved gold nanoparticle-based serology tests for SARS-CoV-2 under EUA designation (as of January 17, 2021) assay based on antibodies, and demonstrated the same sensitivity as PCR detection. Although isothermal amplification techniques simplify the process of nucleic acid amplification to a constant temperature, most of the isothermal amplification methods need to be performed at a temperature of 65 C or higher, which limits their field applications. This limitation has been improved with the development of RPA, which runs only at a constant temperature of 30-42 C. In Ivanov's study, the isolated virus RNA was amplified with a one-step reverse transcription RPA (RT-RPA) at 37 C for only 20 min and then loaded to a typical nucleic acid-based LFA strip ( Figure 16 ). Another study by Khater and Escosura-Muniz (2019) showed that the RPA step can even be performed at room temperature, which further removed the need for a heating source (to be discussed in Section 2.2.3). In a recent study by Khater and coworkers, an electrochemical nucleic acid biosensor was integrated with an in situ preamplification of Citrus tristeza virus DNA for highly sensitive detection. This assay employed solid-phase isothermal RPA technology, which offered many benefits over the standard RPA in a homogeneous phase in terms of sensitivity, portability, and versatility (Khater & Escosura-Muniz, 2019) . Moreover, previous RPA devices are limited by the need for heating sources to reach sensitive detection. Importantly, this study demonstrated a high sensitivity (1 pg/μl) obtained at room temperature by using AuNP-modified sensing substrates and electrochemical impedance spectroscopic detection ( Figure 17 ) (Khater & Escosura-Muniz, 2019) . Although the use of 50 nm AuNP seems successful, incorporating AuNPs with other sizes might potentially further improve the sensitivity. Similar to the combination therapy strategies employed in cancer treatments, we hope this review can stimulate future thoughts and efforts on harnessing multi-amplification strategies in developing AuNP-based assays, in order to meet the persisting clinical need for better sensitivity. At the beginning of the pandemic, COVID-19 is primarily diagnosed by RT-PCR in conjunction with chest computed tomography for suspicious negative cases. Additional PCR assays have been approved by the FDA or are under rapid development to expand diagnosing capability. However, these methods are expensive, time-consuming, and require sophisticated instruments and well-trained personnel, which are not economical for mass screening and not practical in low-resource settings. Portable, fast, sensitive, and affordable POC testing is of crucial importance in controlling the spread of a pandemic before effective treatment and vaccines become available. As aforementioned, AuNP-based diagnostics can be developed to detect nucleic acids and antibodies, with detection limits comparable to, or even better than, RT-PCR and commercial non-AuNP-based ELISA kits. Consequently, AuNP-based SARS-CoV-2 testing is a powerful alternative to RT-PCR and holds great potential for this enormous unmet biomedical need, especially in resource-limited areas. As of January 17, AuNP-based SARS-CoV-2 testing kits have already been approved for use in the United States (Table 2 ) and many other countries (Johns Hopkins website. https://www.centerforhealthsecurity.org/resources/COVID-19/serology/Serology-based-tests-for-COVID-19.html). In this section, we aim to discuss some considerations for developing effective AuNP-based diagnostics for SARS-CoV-2. Despite the rapid increase in publications and commercial products on AuNP-based diagnostics in recent years, not many of them have carefully optimized the size and shape of AuNPs in their assays. To develop highly sensitive testings for SARS-CoV-2, the selection of AuNPs with proper size and shape is as important as the assay development itself. One beauty of using AuNP is that a wide range of sizes (a few to several hundred nanometers) and shapes (e.g., sphere, rod, core-shell, cube, star, cage, pyramid, Janus, etc.) of AuNPs and even hybrids with other nanoparticles can be synthesized in a controlled manner through well-defined approaches (Grzelczak et al., 2008; Zhao et al., 2013) . The size and shape of AuNPs are closely associated with their physical and optical properties, which can greatly influence the performance of AuNP-based diagnostics. For spherical AuNPs, 10-20 nm size is commonly chosen because of the ease of synthesis and good control of monodispersity as both smaller and larger AuNPs tend to have a higher polydispersity index. When developing an assay, depending on the property of AuNP employed, that size range might not be ideal. Generally speaking, larger gold nanospheres have a larger absorption cross-section and magnitude of extinction (Jain et al., 2006) . So for assays that reply on the absorption property, such as LSPR-based as well as many colorimetric assays like LFAs, larger AuNPs have a better chance of obtaining a higher sensitivity relative to smaller AuNPs. Similarly, gold nanoshells tend to have a higher sensitivity than gold nanospheres. However, this assumption always needs to be tested in each assay development as many other factors could influence the ultimate LOD as well. In one study, Khlebtsov et al. (2019) evaluated the size-dependent LODs of an ideal colorimetric LFIA, assuming that one analyte molecule corresponds to one AuNP captured in the test zone, and suggest that the expected LFIA sensitivity can increase for larger AuNP sizes like d À1 (d for diameter). In another study, Kim et al. (2016) analyzed size-dependent LFA performance for HbsAg detection using AuNPs in the size range of 34-138 nm and found 43 nm AuNP exhibited the best performance. However, in an LSPR-based HbsAg sensing assay, Kim et al. (2018) found 15 nm AuNPs have a lower LOD than AuNPs with larger sizes (30 nm, 50 nm). For assays that are not related to the optical property of AuNPs, size of AuNPs might play a different role in determining the sensitivity of an assay. For example, Park et al. developed graphene/AuNP hybrids for norovirus detection based on the catalytic efficiency of NPs. They found the 10 nm AuNP showed the lowest LOD of 92.7 pg/ml from AuNPs in a size range of 10-500 nm likely due to the large surface-to-volume ratio (Ahmed et al., 2017) . Overall, to select the size of AuNPs for SARS-CoV-2 detection assays, one-size-fits-all approaches would not be ideal. One needs to optimize the size of AuNPs in each assay developed to achieve the best performance. In terms of shape, there is no doubt that spherical AuNPs are among the most studied ones due to the ease of synthesis. However, other shapes of AuNPs are worth studying when a higher sensitivity or a different sensing strategy is desired but beyond the reach of gold nanospheres. Among non-spherical AuNPs, gold nanorods (AuNRs) are often chosen for biomedical applications due to their unique characteristics such as large absorption cross-section, high extinction coefficient, and more interestingly, AuNRs display two separate LSPR in the visible/near-IR spectral range, due to transverse and longitudinal oscillations of conduction electrons. Importantly, this longitudinal band can be tuned by adjusting the aspect ratio of AuNRs. AuNPs are commonly used as FRET receptors for biosensors Nasrin et al., 2018; Tsang et al., 2016) . As AuNRs have two absorption bands, they are superior to the spherical AuNPs in multiplex sensing. For example, Zeng et al. reported a FRET nanosensor using green and red quantum dots (QDs) and tuned AuNRs so that the emission spectra of QDs overlap with the two absorption bands of AuNRs respectively. With this design, the researchers can simultaneously detect two different HBsAgs (Zeng et al., 2012) . In another study, Xu et al. reported an H5N1 virus biosensor utilizing the sharp edges of highly uniform gold nanobipyramids (Au NBPs) that displayed a color change upon silver deposition triggered by virus antigen binding. This alkaline phosphatasebased ELISA strategy showed a LOD as low as 1 pg/ml. The vivid colors of the proposed sensing strategy also enabled semiquantitative detection of the analytes with the naked eye (Xu et al., 2017) . This sensing strategy would not succeed without the recent progress on the synthesis of highly homogeneous Au NBPs, which indicates the importance of the design of the shape of AuNPs. Nonetheless, the selection of non-spherical AuNPs may not be necessarily related to the unique physical property associated with the shape. Nikbakht et al. (2014) reported a colorimetric influenza A virus M gene biosensor using AuNRs, which formed aggregates during DNA amplification due to the interaction between LAMP DNA and the positive surface capping agents cetyltrimethylammonium bromide, a critical surfactant used in AuNRs synthesis. It is worth noting that although higher sensitivity is always the goal of any sensor, for better clinical and commercial translation, it is critical to balance the trade-off between sensitivity, complexity, cost-effectiveness, portability, and stability of the AuNP-based colloidal system. The actual application setting (e.g., laboratory, hospital, home) is also an important factor one should not overlook during assay development. The selection of targets for detecting SARS-CoV-2 is different between nucleic acid testing and antibody testing. A summary of representative targets is listed in Table 3 . For nucleic acid testing, targets are selected from key functional genes and genes encoding structural proteins. There are four structural proteins encoded by a coronavirus genome: Spike surface glycoprotein (S), envelope protein (E), matrix protein (M), and nucleocapsid protein (N). Besides these structural proteins, another three genes have also been used for nucleic acid-based SARS-CoV-2 detection: ORF1ab gene, ORF1b-nsp14 gene, and RdRp gene (Udugama et al., 2020) . ORF1ab gene encodes replicase polyprotein 1ab. ORF1b-nsp14 gene encodes nonstructural protein 14. RdRp gene encodes RNA-dependent RNA polymerase. These proteins play an important role in virus RNA transcription and replication . For antibody testing, the Spike protein RBD domain is believed to be the most common target to choose. Spike is a surface protein on viral capsid that mediates cell entry by binding to host cell receptor angiotensin-converting enzyme 2 (Hoffmann et al., 2020) . Functionally, the Spike protein is divided into two subunits. S1 subunit, including the receptor-binding domain (RBD), is responsible for receptor binding. S2 subunit is responsible for cell membrane fusion. Although the full Spike protein could be used as an antigen for antibody detection, the RBD domain is likely the antigen giving the best sensitivity and specificity (Jiang et al., 2020) . Interestingly, Ventura and coworkers developed a SARS-CoV-2 testing by mixing 1:1:1 of three antibody-AuNP conjugates targeting three surface proteins of SARS-CoV-2 (spike, envelope, and membrane). This assay reported a detection limit approaching that of the real-time PCR, although both the ratio and the size of AuNPs are still susceptible to optimization to allow one to push even further the LOD. It is worth noting that because this biosensor relies on its sensitivity to the virion rather than to its content (RNA), it offers a powerful tool to quantify the viral load, and is apt to assess the actual degree of infectiveness of a specimen, a nontrivial issue in diagnostic assays in virology (Ventura et al., 2020) . Passive adsorption and covalent conjugation are the two most commonly used strategies to conjugate ligands such as antibodies, proteins, aptamers, or DNA/RNA oligos to AuNPs. Passive adsorption is relatively straightforward and also effective in conjugating certain ligands to AuNPs. However, this method has several drawbacks. These include desorption of the ligands from the gold surface over time under certain conditions (e.g., salt and pH changes). Any detachment of ligands from the particle surface can result in compromised assay sensitivity, susceptible particle stability, and even false-positive testing results. On the other side, covalent conjugation represents a popular conjugation strategy for AuNPs thanks to the ease of gold-thiol chemistry. Besides that, covalent conjugation also favors several benefits. First, F I G U R E 1 9 Schematic representation for the selective naked-eye detection of SARS-CoV-2 RNA mediated by the suitably designed ASO-capped AuNPs. Reprinted with permission from Moitra et al. (2020) . American Chemical Society covalent conjugates offer increased stability in difficult sample conditions (high salt or detergent concentrations), which is important for many assays that deal with clinical samples. Second, the ligand-to-particle ratio can be precisely controlled, which is important for optimizing assay sensitivity, providing reproducible conjugates and reliable quantitation of analytes. Recently, a photochemical immobilization technique (PIT), which involves using a 254 nm UV light to disrupt the disulfide bridges located next to the tryptophan residues, has been applied for surface functionalization of antibodies to AuNPs for SARS-CoV-2 detection (Ventura et al., 2020) . PIT not only always exposed Fab to make AuNP highly "reactive," but also avoided using any linker (e.g., protein A), the latter being detrimental for the plasmonic interactions among AuNPs on which the colorimetric biosensor is based (Ventura et al., 2020) . In another study, developed an AuNP/RNA conjugate through a dithiocarbamate functional group, which showed improved stability and less premature ligand release over using traditional monothiol linker at high ionic strength and in the presence of reducing reagents. Other conjugation strategies such as antibody orientation, with or without PEG backfilling, length of PEG chains or other biolinkers, ligand coverage on AuNP, and so on, all have implications of LOD for the assay development (Avvakumova et al., 2019; Oliveira et al., 2019; Tam et al., 2017; Wei et al., 2013) . COVID-19 testings include nucleic acid-based testing and antibody-based testing. Despite nucleic acid testing being the gold standard for diagnosing COVID-19, antibody testing can be used as a good complementary test for several reasons. First, although qRT-PCR is the tried-and-true method for nucleic acid testing, it can hardly meet needed demands due to the rapid growth of the disease, limited accessibility of the instruments, and lengthy testing time. Second, for suspected cases where nucleic acid detection was negative, antibody testing could help to determine the status of the infection. For example, if it tests positive, it could mean that the patient has been exposed to, and recovered from SARS-CoV-2 or possibly a related coronavirus. These tests are important in the fight against the pandemic by providing information on disease prevalence and the frequency of asymptomatic infection, and also by identifying potential donors of "convalescent plasma," an approach in which blood plasma containing antibodies from a recovered individual serves as a therapy for an infected patient with a severe or immediately life-threatening disease. Importantly, we must point out that a negative antibody test not necessarily indicates negative current infection. It might just be in the early stage as antibodies do not show up for 1-3 weeks or even longer after infection and some people may not develop antibodies at all. So far, LFA is no doubt the mainstream assay format for AuNP-based IVD due to portability, rapidity, ease of use, and low cost. This is explicitly supported by the fact that all AuNP-based SARS-CoV-2 tests are lateral flow assays (Table 2) . Li et al. designed an AuNP-based LFIA strip that can simultaneously diagnose IgG and IgM for COVID-19 ( Figure 18 ). There were two test lines under the control line, the G line and M line, which were immobilized with mouse anti-human IgG and mouse anti-human IgM for IgG and IgM detection, respectively. C line is the control line, which is immobilized with anti-rabbit antibodies. The conjunction pad is dispensed with two types of conjugated AuNP: one is COVID-19 antigen-AuNP for binding potential with COVID-19 IgG/IgM antibodies, and the other is rabbit IgG-AuNP for binding to the control line. The main benefit of simultaneous IgG and IgM testing is that it can potentially recognize a COVID-19 infection earlier as IgM antibodies usually appear before IgG. Time is vital in the race against COVID-19. Moreover, simultaneous IgG/IgM testing can have a higher sensitivity and specificity than IgG or IgM testing alone. The antibody level in blood is fluctuating during the period of infection. IgM appears early but is not lasting. IgG has a higher binding affinity to antigen and is more abundant than IgM, meaning IgG testing usually has a higher sensitivity and specificity. Overall, combined IgG/IgM testing can rule out potential false negatives. The authors were able to achieve a sensitivity of 88.66% and specificity of 90.63% over 397 positive and 128 negative clinical samples and a 100% detection consistency in fingerstick blood, serum, and plasma of venous blood. However, the detection limit of this assay and different-sized AuNPs (other than 40 nm) were not studied. Antibody-based testing is certainly helpful in evaluating past COVID-19 infections; however, it is incapable by itself of identifying whether an individual is experiencing a current infection. Moreover, although adding IgM detection could potentially help to diagnose COVID-19 earlier than IgG detection only, it still takes several days to weeks after infection for a patient to develop a detectable antibody response. Therefore, AuNP-based nucleic acid testing is highly valuable and needed for an urgent unmet need in COVID-19 diagnosis. Recently, Moitra et al. developed a colorimetric assay based on 10 nm AuNPs, coated with antisense oligonucleotides specific for N-gene of SARS-CoV-2, for rapid (⁓5 min after RNA isolation) and selective detection. This assay reported a LOD of 0.18 ng/μl with a tested dynamic range of 0.2-3 ng/μl by measuring OD 660 . The authors further adapted the assay to a visual "naked-eye" detection by adding a 5 min incubation step with RNase H at 65 C ( Figure 19 ). This allows a layman to easily detect the presence of SARS-CoV-2 without the requirement of any sophisticated instrumental techniques (Moitra et al., 2020) . Another study by Qiu et al. (2020) reported a gold nanoisland-based nucleic acid sensor specific for the SARS-CoV-2 E gene with a LOD of 0.22 pM. Although great efforts and progress have been made for the development of AuNP-based assays, additional potential directions could be explored to better meet the COVID-19 detection need. For example, an isothermal amplification approach could be integrated into nucleic acid testing to meet the sensitivity requirement for real samples containing only trace amounts of the virus during the early stage of infection, which was the main reason for many false negatives. Microfluidics technology is well suited for POC diagnostics, which needs fewer samples and reagents and is capable of handling high throughput samples. Although AuNP-based microfluidic assays have been reported for viral detection, in the case of COVID-19 detection, it is yet to be seen. In addition, device sensitivity and specificity could be further improved in combination with other nanotechnology-based detection strategies. For instance, our group has demonstrated significantly improved capture efficiency of biomarkers in blood using multivalent binding effect mediated by dendrimer nanoparticles (Myung et al., 2018; Poellmann et al., 2020) . Multivalency-induced binding affinity enhancement has also been reported in AuNPs (Riley & Day, 2017; Wang et al., 2020) . Overall, we expect more AuNP-based COVID-19 sensors with the ASSURED criteria (i.e. affordable, sensitive, specific, user-friendly, rapid and robust, sophisticated equipment-free, delivered to the end-users) will be developed in the near future. AuNP-based sensors have gained substantial interest in both academia and industry in the past two decades. In this review, we described the recent advances in AuNP-based virus detection. Furthermore, in light of the current outbreak of the COVID-19 pandemic, we particularly discussed considerations for the design of AuNP-based SARS-CoV-2 testings. These examples prove that AuNP-based sensors can offer great advantages over conventional methods such as ELISA, PCR, western blot, and many others. Although much progress has been made, many key parameters need to be considered and optimized before AuNP-based diagnostics can realize their full potential in future applications and advance current technologies beyond conception. (1) High sensitivity and specificity. There is no doubt that high sensitivity will always be the goal of AuNP-based IVDs considering the high sensitivity of many other conventional assays (e.g., ELISA, RT-PCR) and the low abundance of many analytes. Importantly, specificity should be another critical factor taken into account during the assay development phase. Assays that demonstrate high specificity in distinguishing analytes from their close similarities (e.g., serotypes) hold more promise for success in future markets. (2) Portability/wearability. Portability is of crucial importance to POC and wearable IVDs. Portability means the size and weight of the relevant equipment are favorable for carrying and the assay can maintain functions in ambient conditions. AuNP conjugates are known for good stability and robustness as the LFA strip is a good example. AuNP-based assays that can be miniaturized and require low maintenance storage conditions will hold more promise towards portability. Wearability will be favorable for long-term monitoring. (3) Quantifiability. Quantitative assays can not only help to exclude false positives/negatives resulting from subjective judgment, but also help to improve the LOD. (4) Mass production. Mass production means the IVD manufacture needs to meet the standardization requirement among batches. AuNPs are known for their scalable and tunable synthesis. However, better control and reproducibility of the AuNP bioconjugation process need to be addressed. (5) Smart networking. With the fast development of smart devices, more and more technologies (e.g., phones, TV, cars, etc.) are becoming smart, and so are IVDs. One of the future directions for AuNP-based IVDs development is to integrate with a device (e.g., smartphone) to aid with reading, reporting the results of the diagnosis, and interacting with their care providers. (6) High-throughput. High-throughput capability is of critical importance in situations that deal with massive samples, such as during an epidemic or pandemic. Localized surface plasmon resonance-mediated fluorescence signals in plasmonic nanoparticle-quantum dot hybrids for ultrasensitive Zika virus RNA detection via hairpin hybridization assays Enhanced catalytic activity of gold nanoparticle-carbon nanotube hybrids for influenza virus detection Optoelectronic fowl adenovirus detection based on local electric field enhancement on graphene quantum dots and gold nanobundle hybrid Size-controlled preparation of peroxidaselike graphene-gold nanoparticle hybrids for the visible detection of norovirus-like particles A highly sensitive electrochemical immunosensor for hepatitis B virus surface antigen detection based on Hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme-signal amplification Does conjugation strategy matter? Cetuximab-conjugated gold nanocages for targeting triple-negative breast cancer cells A serological point-of-care test for the detection of IgG antibodies against Ebola virus in human survivors Zika immunoassay based on surfaceenhanced Raman scattering nanoprobes Microfluidic platform integrated with graphene-gold nano-composite aptasensor for one-step detection of norovirus Enhanced detection of infectious pancreatic necrosis virus via lateral flow chip and fluorometric biosensors based on self-assembled protein nanoprobes Polymerase chain reaction-free detection of hepatitis B virus DNA using a nanostructured impedance biosensor Detection of influenza viruses by coupling multiplex reverse-transcription loop-mediated isothermal amplification with cascade invasive reaction using nanoparticles as a sensor Multiplex reverse-transcription loop-mediated isothermal amplification coupled with cascade invasive reaction and nanoparticle hybridization for subtyping of influenza a virus Polydimethylsiloxane-paper hybrid lateral flow assay for highly sensitive point-of-care nucleic acid testing Nanoparticle-based LDI-MS immunoassay for the multiple diagnosis of viral infections Applications of gold nanoparticles in virus detection Femtomolar detection of dengue virus DNA with serotype identification ability A SERS-based lateral flow assay biosensor for highly sensitive detection of HIV-1 DNA Ultrasensitive paper based nucleic acid detection realized by three-dimensional DNA-AuNPs network amplification Size-and distance-dependent nanoparticle surface-energy transfer (NSET) method for selective sensing of hepatitis C virus RNA. Chemistry (Weinheim an der Bergstrasse Shape control in gold nanoparticle synthesis SARS-CoV-2 cell entry depends on ACE2 and TMPRSS2 and is blocked by a clinically proven protease inhibitor Dual-signal readout nanospheres for rapid point-of-care detection of Ebola virus glycoprotein A photoelectrochemical immunosensor based on gold nanoparticles/ZnAgInS quaternary quantum dots for the high-performance determination of hepatitis B virus surface antigen Nucleic acid lateral flow assay with recombinase polymerase amplification: Solutions for highly sensitive detection of RNA virus Calculated absorption and scattering properties of gold nanoparticles of different size, shape, and composition: Applications in biological imaging and biomedicine Applications of gold nanoparticles in non-optical biosensors Neutralizing antibodies against SARS-CoV-2 and other human coronaviruses Detection of hepatitis B virus antigen from human blood: SERS immunoassay in a microfluidic system In situ plant virus nucleic acid isothermal amplification detection on gold nanoparticle-modified electrodes Quantifying the numbers of gold nanoparticles in the test zone of lateral flow immunoassay strips Advancement of capture immunoassay for real-time monitoring of hepatitis E virus-infected monkey Enhanced colorimetric detection of norovirus using in-situ growth of Ag shell on Au NPs Development of lateral flow assay based on size-controlled gold nanoparticles for detection of hepatitis B surface antigen Heteroassembled gold nanoparticles with sandwich-immunoassay LSPR chip format for rapid and sensitive detection of hepatitis B virus surface antigen (HBsAg) Streptavidin-conjugated gold nanoclusters as ultrasensitive fluorescent sensors for early diagnosis of HIV infection A multi-functional gold/iron-oxide nanoparticle-CNT hybrid nanomaterial as virus DNA sensing platform Binary nanoparticle graphene hybrid structure-based highly sensitive biosensing platform for norovirus-like particle detection Rapid and sensitive determination of HIV-1 virus based on surface enhanced Raman spectroscopy Label-free localized surface plasmon resonance biosensor composed of multi-functional DNA 3 way junction on hollow Au spike-like nanoparticles (HAuSN) for avian influenza virus detection Development and clinical application of a rapid IgM-IgG combined antibody test for SARS-CoV-2 infection diagnosis Identification of newly emerging influenza viruses by surface-enhanced Raman spectroscopy Multiplex electrochemiluminescence DNA sensor for determination of hepatitis B virus and hepatitis C virus based on multicolor quantum dots and Au nanoparticles A novel immunosensor based on excessively tilted fiber grating coated with gold nanospheres improves the detection limit of Newcastle disease virus Metal (Au, Pt) nanoparticle-latex nanocomposites as probes for immunochromatographic test strips with enhanced sensitivity Selective naked-eye detection of SARS-CoV-2 mediated by N gene targeted antisense oligonucleotide capped Plasmonic nanoparticles Targeting helicase-dependent amplification products with an electrochemical genosensor for reliable and sensitive screening of genetically modified organisms Multivalent binding and biomimetic cell rolling improves the sensitivity and specificity of circulating tumor cell capture Fully printed one-step biosensing device using graphene/AuNPs composite Fluorometric virus detection platform using quantum dots-gold nanocomposites optimizing the linker length variation Single-step detection of norovirus tuning localized surface plasmon resonance-induced optical signal between gold nanoparticles and quantum dots Surface-enhanced Raman scattering (SERS) detection of multiple viral antigens using magnetic capture of SERS-active nanoparticles Nanomolecular detection of human influenza virus type A using reverse transcription loop-mediated isothermal amplification assisted with rod-shaped gold nanoparticles Magnetic nanozyme-linked immunosorbent assay for ultrasensitive influenza a virus detection Impact of conjugation strategies for targeting of antibodies in gold nanoparticles for ultrasensitive detection of 17β-estradiol A sandwich-type electrochemical immunosensor based on RhPt NDs/NH2-GS and Au NPs/PPy NS for quantitative detection hepatitis B surface antigen Immunoavidity-based capture of tumor exosomes using poly(amidoamine) dendrimer surfaces Dual-functional plasmonic photothermal biosensors for highly accurate severe acute respiratory syndrome coronavirus 2 detection Frizzled7 antibody-functionalized nanoshells enable multivalent binding for Wnt signaling inhibition in triple negative breast cancer cells Causes of death. Our World in Data Electrochemical detection of influenza virus H9N2 based on both immunomagnetic extraction and gold catalysis using an immobilization-free screen printed carbon microelectrode Sub-femtomolar detection of HIV-1 gene using DNA immobilized on composite platform reinforced by a conductive polymer sandwiched between two nanostructured layers: A solid signal-amplification strategy Gold aggregating gold: A novel nanoparticle biosensor approach for the direct quantification of hepatitis C virus RNA in clinical samples Electrochemical lateral flow immunosensor for detection and quantification of dengue NS1 protein A sensitive label-free impedimetric DNA biosensor based on silsesquioxane-functionalized gold nanoparticles for Zika virus detection Versatility of a localized surface plasmon resonance-based gold nanoparticle-alloyed quantum dot nanobiosensor for immunofluorescence detection of viruses A comparison of nanoparticle-antibody conjugation strategies in sandwich immunoassays Ultrasensitive detection of Ebola virus oligonucleotide based on upconversion nanoprobe/nanoporous membrane system Diagnosing COVID-19: The disease and tools for detection Localized surface plasmon resonance biosensing: Current challenges and approaches Colorimetric test for fast detection of SARS-CoV-2 in nasal and throat swabs Inhibition of Wnt signaling by Frizzled7 antibody-coated nanoshells sensitizes triple-negative breast cancer cells to the autophagy regulator chloroquine siRNA delivery using dithiocarbamate-anchored oligonucleotides on gold nanorods Visual DNA diagnosis of tomato yellow leaf curl virus with integrated recombinase polymerase amplification and a gold-nanoparticle probe Ultrasensitive colorimetric detection of murine norovirus using NanoZyme aptasensor. Analytical Chemistry Gold nanoparticles (GNPs) as multifunctional materials for cancer treatment Analysis of therapeutic targets for SARS-CoV-2 and discovery of potential drugs by computational methods Enhanced fluorescence ELISA based on HAT triggering fluorescence "turn-on" with enzyme-antibody dual labeled AuNP probes for ultrasensitive detection of AFP and HBsAg Digital single virus electrochemical enzyme-linked immunoassay for ultrasensitive H7N9 avian influenza virus counting Smartphone-based point-of-care microfluidic platform fabricated with a ZnO nanorod template for colorimetric virus detection A colorimetric method for H1N1 DNA detection using rolling circle amplification Highly sensitive naked-eye assay for enterovirus 71 detection based on catalytic nanoparticle aggregation and immunomagnetic amplification Ultrasensitive virion immunoassay platform with dual-modality based on a multifunctional aggregation-induced emission luminogen Highly uniform gold nanobipyramids for ultrasensitive colorimetric detection of influenza virus Gold nanoparticle-mediated nucleic acid isothermal amplification with enhanced specificity. Analytica Chimica Acta Multiple homogeneous immunoassays based on a quantum dots-gold nanorods FRET nanoplatform Diagnosis of rubella virus using antigen-conjugated Au@Pt nanorods as nanozyme probe State of the art in gold nanoparticle synthesis Rational construction of a DNA nanomachine for HIV nucleic acid ultrasensitive sensing Gold nanoparticles for in vitro diagnostics Competitive adsorption on gold nanoparticles for human papillomavirus 16 L1 protein detection by LDI-MS Ultrasensitive detection of HIV DNA with polymerase chain reaction-dynamic light scattering Rapid detection of severe fever with thrombocytopenia syndrome virus via colloidal gold immunochromatography assay Gold nanoparticles in virus detection: Recent advances and potential considerations for SARS-CoV-2 testing development The authors have declared no conflicts of interest for this article. Data sharing is not applicable to this article as no new data were created or analyzed in this study.