key: cord-0974477-iavihaur authors: Wojtasz, Izabela; Jaracz, Krystyna; Sobczyński, Paweł; Drużdż, Artur; Dyk, Danuta; Kaźmierski, Radosław title: The impact of FFP3 respirators on the blood saturation date: 2022-01-25 journal: Sci Rep DOI: 10.1038/s41598-022-05319-3 sha: d8a78feb072896a46b364d7a440862ead3739735 doc_id: 974477 cord_uid: iavihaur This study aims to investigate whether wearing a filtering facepiece class 3 respirators with personal protective equipment (FPP3/PPE) during work in the intensive care unit (ICU) affects the blood saturation (SpO2), the heart rate (HR), and the well-being of health care workers (HCWs). This preliminary study included a group of 21 volunteers (including 16 females (76%), with a median age of 23 years). Each worker served as his own control and performed the test two times: they wore the FFP3/PPE and did not wear it for a three-hour shift in the ICU. The working with an FFP3/PPE compared to not working with an FFP3/PPE caused a significant, but within normal ranges, influence on the level of SpO2 with a mean decrease of − 1.43%. The highest reduction in the SpO2 was − 2.29% and occurred after 150 min of work. All of the score scales of the well-being markers increased consecutively but moderately during the shift while wearing the FFP3/PPE. We assume that a 3-h shift rhythm is a safe and reliable solution, i.e., three hours of working in the FFP3/PPE in the ICU, followed by rest or working without an FFP3/PPE. www.nature.com/scientificreports/ melt-spun non-wovens; and thermal conductive textiles, as well as thermoelectric modules that deliver a steady and sustainable cooling effect through thermal contact with human skin 14 . As far as masks are concerned, there were efforts to apply auxiliary components into face masks to enrich the functionalities and improve the daily monitoring and early warning of potential danger. Therefore, (bio)sensors are embedded in the masks, which serve as effective support for passive personal protection. Another achievement is a self-disinfecting mask which could be purified by built-in high voltage, and others 11, 14, 15 While most of the recent studies concern FFP2 respirators, surprisingly few reports have shown the influence of wearing FFP3 respirators on the blood saturation and the well-being of HCWs working in hospitals' intensive care units (ICU) or COVID-19 departments 16, 17 . One of the hypotheses assumes that masks can increase resistance to inspiration and respiration, which could decrease the efficacy of breathing 18 . The problem concerns intensive care specialist doctors and nurses who often spend long hours in full PPE with FFP3 respirators in emergency or COVID-19 dedicated departments. This study aims to investigate whether wearing the face masks, FFP3 and PPE (FPP3/PPE), while working in the ICU affects the blood saturation, the heart rate (HR), and the well-being of HCWs. We attempt to reject the null hypothesis that there is no relation between wearing FFP3/PPE and the blood saturation, heart rate, and well-being of HCPs. Study time and participants. The study was performed in February and March 2021 in the Department of Anesthesiology and Intensive Therapy (DAIT) of Poznan University of Medical Sciences. All the HCWs working on the day shifts in the DAIT during the third peak of the pandemic were asked to take part in the study, and 21 of them agreed. Therefore, the study included a group of 21 volunteers (including 16 females (76%) and five males), with a median age of 23 years, with interquartile ranges (IQRs) of the participants (21) (22) (23) (24) (25) (26) (27) , range of 20-59. The study group consisted of intensive care registered nurses (RN, MSc or RN, BSc) (n = 3), nursing students (of second and third years of study) (n = 14), medical students (fifth year) (n = 3), and a senior consultant (MD, PhD) of the department. All of the students participating in the experiment were students in our university, and all were Caucasian. All participants had valid medical examinations and were allowed to work by the recognized occupational doctor, and all were vaccinated twice with the COVID-19 vaccine (Pfizer/BioNTech). Persons with a history of pulmonary disease, anemia, vascular diseases, and other diseases that could limit respiratory function were excluded from the study. To evaluate the effects of wearing the respirators, we used a counterbalanced crossover design-a self-controlled trial. We wanted to rule out the possibility of natural changes in the pulse oximetry (SpO2) and heart rate parameters during the normal functioning of the participants. Therefore, each subject served as his own control and performed the test two times: (1) without a face mask and PPE (control) for three hours and (2) wearing an FFP3 respirator with full PPE for a 3-h shift in the intensive care unit. The first measurements ("time point 0") of the SpO2 and pulse rate were recorded 2 min after fitting the FFP3/PPE to give participants time to adapt themselves. The study was performed during the third peak of the COVID-19 pandemic. Although the department was not an isolation ward dedicated only to COVID-19 patients, all emergency admissions were made before obtaining the test for a SARS-CoV-2 infection. Therefore, the applicable unit protocol required the team to wear the PPE and masks. During the test runs without masks and PPE, we encouraged the participants to perform each hour's same exercises for at least 10 min with the supervision of the study coordinator (IW). Among the study participants, we had students; therefore, for safety and controlling reasons, we used the Nellcor PM10N monitoring system, which allows the study coordinator to assess the recorded parameters in real time (Fig. 1) . To avoid bias, each subject's sequence of interventions (test run or shift run) were randomly assigned. Strenuous physical activity was prohibited during the 24 h preceding the test, and a night sleep of at least 6 h was mandated 17 . We also asked the participants not to use any fingernail polish. Each volunteer was wearing the same type of respirators and PPE. We used FFP3 masks- Additionally, every 30 min during the three-hour shift and during the control run, each subject completed a questionnaire concerning their well-being, with a score scale (ranging from 0 (no symptoms) to 6 points (unable to work)) for headache, shortness of breath, perspiration, fatigue, and thirst (see Table 1 ). More details about the score were provided in the Supplemental materials (Supplement 1). Statistical methods. To www.nature.com/scientificreports/ were reported (Table 1 ). All pairwise comparisons were made using the Mann-Whitney U-test 19 . Due to the number of all the measurements over time, we expected statistically significant differences between the medians. To measure the differences between the groups, we calculated the 95% confidence intervals or interquartile range for the differences of the medians. Tables 2 and 3 present the results of the linear mixed-effects model (LMM) estimating the influence of working with the FFP3/PPE in the HCWs, the demographic factors and the levels of SpO2 [%]. LMM is a generalization of the standard linear model used, as the measurements are permitted to exhibit correlation and nonconstant variability between the individuals. LMM, therefore, provides the flexibility of modeling not only with the means but also with their variances and covariances. Moreover, LMM is recognized as a type of method that has some crucial advantages over repeated-measures ANOVA 20 . Table 4 presents a comparison of the different well-being markers between the 30-min time points while working in the FFP3/PPE versus not working in the FFP3/PPE. In such cases, Friedman's one-way repeated measures analysis of variance by ranks (Friedman test) 21 was used to estimate the differences between consecutive groups (i.e., experiencing various ailments after 30, 60, 90, 120, 150, and 180 min). Statistical analysis was performed using RStudio (Version 1.3.1073). Nellcor PM 10 N monitoring system on a volunteer's hand. Such localization for safety and controlling reasons allowed the study coordinator to assess the recorded parameters in real time. www.nature.com/scientificreports/ Consent for publication. All authors have given their consent for publication. We obtained 404,195 measurements of blood saturations (SpO2) in general. There were 156,113 and 248,082 measurements without and with the FFP3/PPE, respectively. The median SpO2 without and with the FFP3/PPE was 99% (IQR 98-100%) and 97% (IQR 96-98%), respectively. The difference was significant (p < 0.001). The median number of pulse beats per minute (HR) without and with the FFP3/PPE was 76 (IQR 71-84) and 104 (IQR 91-117), respectively, and the difference was also significant (p < 0.001). The mean results of the SpO2 and HR for the whole shift duration of the HCWs in the FFP3/PPE and without the FFP3/PPE with a breakdown based on sex and age category are shown in Table 1 . Men generally had a lower SpO2 (by 1%) and a lower pulse rate (by 22 PB/min) while wearing the FPP3/PPE than women and also had a lower SpO2 (by 2%) and a lower pulse rate (by 2 PB/min) when not wearing the FFP3/PPE. The older group showed a slightly lower SpO2 and HR when wearing the FFP3/PPE and when not wearing the FFP3/PPE and had a slightly higher pulse rate without the FFP3/PPE than the younger group ( Table 1) . The model demonstrated the influence of working in the FFP3/PPE on the SpO2 when sex and gender were considered, and results are shown in Table 2 . The reduction of the standard deviation measured from this model due to the variability between the measurements of the individual features was equal to 32.4%. This means that working in the FFP3/PPE had a significant influence on the SpO2, and it was associated with an average decrease in the SpO2 by 1.42% (p < 0.001) in comparison to measurements done without this kind of PPE. Additionally, we developed a mixed-effects model that considered the fact of wearing the FFP3 in an interaction with the time of measurements (periods of each consecutive 30 min). The mixed model demonstrated that HCWs wearing the FFP3/PPE compared to the period than did not work in the FFP3/PPE had a significant influence on the levels of SpO2. A decrease in the SpO2 was observed after 30 min from the start of work, and the highest reduction in the SpO2 (− 2.29%) occurred after 120 min, and after 150 min, the decrease was − 2.19%. At 3 h, we noticed a decrease in the SpO2 of − 1.68%, and the mean decrease in the SpO2 within a 3-h shift was − 1.43%. We also found a significant increase in the HR after 60, 90, and 120 min from the start of work to 18, 8.5 , and 13 PB/min., respectively. (The LMM, which investigates the influence of wearing the FFP3/PPE on the HR along with the interaction effect on the time of measurement, is shown in the supplementary materials, see Supplement 2 for details). The changes in the SpO2 and HR during the 30-min episodes throughout the study time are depicted in Fig. 2 . All of the score scales of the well-being markers increased consecutively with the time spent working in the FFP3/PPE (see Table 4 ). The most notable differences between the beginning and the last 30 min of a shift were observed for fatigue, thirst, and sweating. For all of the parameters, the median score of the scale was 2 (out of a maximum score of 6). There was no score checked during test runs without the FFP3/PPE, where the median score was taken as a 0. Additionally, we did not find any differences between women and men or between younger and older (> 35 years) HCWs in terms of the results of the above scoring scale that depicted the well-being of the HCWs. In our study, SpO2 and HR were measured continuously (we collected over 400,000 measurements for all 21 participants). This allowed us to construct more reliable mixed model formulas. The main finding of this study was that working in an FFP3/PPE caused a moderate but significant decrease in the SpO2. The median decrease in the SpO2 within 3 h of the shift was approximately 2% to 3% (dropping from 99 to 97% or 96%, depending on the time after the shift start), but this did not reach the levels that are recognized as dangerous for health. We also found that the HR increased from 77 to 110 pulse beats/minute (PB/ min) within the same periods in the shifts. The decrease in the SpO2 could be observed after the first 30 min of a shift. The difference was significant until the end of shift, i.e., after 150-180 min of working. However, after a significant drop in the SpO2 within the first period (2-30 min), the following 30-min consecutive periods did not differ significantly, demonstrating a stable decrease in this parameter (see Fig. 2 ). To a lesser extent, we observed an increase in the HR. It was noticed to be the most prominent by 13 to 18 PB/ min, compared the first 30-min period to the periods between 60 and 120 min of the shift (see Fig. 2 ). We found lower SpO2 and pulse rates in men than in women (Table 1) . Normal SpO2 readings usually range from 95 to 100% 23 . Values under 90% are considered low, and values of 92% are sufficient to predict adequate oxygenation in Caucasian persons (a saturation of 95% is usually required in persons of African descent) 24 . Therefore, the obtained results do not exceed the level that is considered safe. Similarly, the self-assessed shortness of breath was relatively mild as a median score for the first 120 min of the shift was 0, and in the last 60 min, the score was 1. The most severe problems associated with PPE and impermeable materials, as thirst and perspiration were the most prominent ailments-for both, the median scores were 2 in the last 30 min of the shift. Regarding the question of how wearing masks influence the SpO2, there is high heterogeneity in the literature. Different kinds of masks were tested under different experimental conditions [16] [17] [18] [25] [26] [27] [28] . Beder et al. obtained similar results while studying disposable sterile one-way surgical paper face masks and revealed a consecutive decrease in the SpO2 during the 2 and 3 h of surgical operations (drop by 1% and 1.5%, respectively) and a slight increase in HR compared to preoperative values in the surgeons. The decrease in the saturation was more prominent in surgeons aged over 35 25 . Recently, Fantin performed an arterial blood gas analysis in a 30-year-old female resident, which was carried out during a 13-h day shift on the COVID-19 Intensive Care Unit. This study found that during the multihour www.nature.com/scientificreports/ wearing of FFP3 masks, all measured values were within the normal ranges, although a trend toward an insufficient gas exchange could be seen. She had an increase in the partial pressure of carbon dioxide (PaCO2), from 29.3 to 36.7 mmHg, showing a continuous decrease during the shift in the partial pressure of oxygen (PaO2), from 102 to 88.8 mmHg. The changes could be seen within the first five hours of the trial; unfortunately, the study consisted of just one young volunteer. Therefore, no further conclusions can be drawn from the study 17 . In another study, 20 young (mean age of 29 years) oral surgeons were enrolled. The SpO2 was measured twice, before and after oral surgeries were performed. They used disposable sterile one-way surgical paper masks and FFP2 masks combined, which could not be formally treated as a reliable substitute for FFP3 masks. Nevertheless, the results corresponded with ours. In all 20 surgeons wearing the FFP2 respirators covered by surgical masks, a reduction in the SpO2 from approximately 97.5% before surgery to 94% after surgery was noted. Additionally, before surgery, the mean HR was 60 ± 9 beats/min, and after surgery, the dentists' HR increased to 98 ± 12 beats/ min . Shortness of breath and light headedness/headaches were also noted. The durations of most of the operations were between 20 and 120 min (the shortest one was less than 20 min, and the longest was up to 240 min). The main difference between our methodology and the study performed in the oral surgeons was that the SpO2 and HR were measured twice at the beginning and after the surgery. Therefore, we cannot exclude any www.nature.com/scientificreports/ fluctuations of the SpO2 and HR levels during surgery 16 . Another recent review demonstrated that face masks, including N95 respirators, surgical masks, and cloth face masks, may have some but relatively small and often difficult-to-detect effects on the work of breathing (which could cause dyspnea), blood gases, and other physiological parameters during physical activity, even with heavy exercise [26] [27] [28] . Our model is easy to repeat and to perform comparative tests but has some shortcomings. Our study results should be considered preliminary. In the Department where the study was conducted, we have a rather young team of HCWs. We did not find any important, from a clinical point of view, differences between the older and younger HCWs (HCWs over 35 years of age had their SpO2 drop from 97 to 96%, while the younger HCWs had their SpO2 drop from 99 to 97% without and with the FFP3/PPE, respectively (see Table 1 for details)). Therefore, it seems that with regard to the young and middle-aged HCWs, there were no essential differences of the assessed parameters between sex and age groups. However, we cannot exclude the possibility that a higher number of participants at an older age, especially those over 50 or 60 years of age, could have different results. The next problem is that we performed this study during only one 3-h shift. However, another "real world" study, which evaluated staff wearing the PPF2/PPE and working in the COVID-19 Isolation Ward, demonstrated that during the next 3 h of a shift (after 3 h of rest), the results of physiological parameters and well-being score scales did not differ from the first shifts. Therefore, we can assume that 3 h of rest between 3 h of shifts was sufficient to regenerate the health of the staff members, while taking into consideration a 12-h shift (with the pattern: 3 h of working-3 rest-3 working-3 rest, (unpublished data)). However, we should take into consideration that HCWs have been working in shifts throughout the whole pandemic period that has now exceeded two years. Therefore, to avoid burn-out and chronic fatigue syndromes, we should seek to ensure as much comfort as possible while working [29] [30] [31] . In particular, rules should be taken to avoid extensive working hours, to ensure the provision of advanced equipment-especially more comfortable gowns and respirators-and to maintain a high level of occupational safety, health care, proper social conditions and compliance for the rules of the law and other health and safety requirements. Some countermeasures to avoid health risks of HCWs have been take and has already been discussed in the introduction. Additionally, we should bear in mind that any of the disadvantages connected with wearing an FFP3/PPE should be considered in the context of the significant reduction of the risks of contracting a SARS-CoV-2 infection by HCWs and, consequently significantly decreasing the risk of the transfer of infection to our patients in hospital wards [1] [2] [3] [4] [5] [6] . Respiratory virus shedding in exhaled breath and efficacy of face masks COVID-19 Systematic Urgent Review Group Effort (SURGE) study authors. Physical distancing, face masks, and eye protection to prevent person-to-person transmission of SARS-CoV-2 and COVID-19: A systematic review and meta-analysis Lack of COVID-19 transmission on an international flight Association between universal masking in a health care system and SARS-CoV-2 positivity among health care workers Association between implementation of a universal face mask policy for healthcare workers in a health care system and SARS-CoV-2 positivity testing rate in healthcare workers Face masks: Benefits and risks during the COVID-19 crisis Updated Healthcare Infection Prevention and Control Recommendations in Response to COVID-19 Appareils de Protection Respiratoire et Métiers de la Santé. Fiche Pratique de Sécurité. ED 105. inrs.fr. INRS What you need to know An evidence review of face masks against COVID-19 National Institute for Occupational Safety and Health. NIOSH Guide to the Selection and Use of Particulate Respirators Certified Under FFP3 respirator face fit testing: What is it all about? A critical synthesis of current peer-reviewed literature on the environmental and human health impacts of COVID-19 PPE litter: New findings and next steps Advanced materials for personal thermal and moisture management of health care workers wearing PPE Materials in advanced design of personal protective equipment: A review Protective face masks: Effect on the oxygenation and heart rate status of oral surgeons during surgery The effect of wearing an FFP3 mask (3MTM AuraTM) with an exhalation valve on gas exchange in medical staff Exercise with facemask; are we handling a devil's sword? A physiological hypothesis Nonparametric Statistical Methods 2nd edn Linear mixed-effects models for within-participant psychology experiments: An introductory tutorial and free, graphical user interface (LMMgui) World Medical Association Declaration of Helsinki: Ethical principles for medical research involving human subjects Definition. Mayo Foundation for Medical Education and Research Beside monitoring of pulmonary function Preliminary report on surgical mask induced deoxygenation during major surgery Face masks and the cardiorespiratory response to physical activity in health and disease Peripheral oxygen saturation in older persons wearing nonmedical face masks in community settings Wearing of cloth or disposable surgical face masks has no effect on vigorous exercise performance in healthy individuals Burnout in intensive care unit workers during the second wave of the COVID-19 pandemic: A single center cross-sectional Italian study Quality of life, physical activity and burnout syndrome during online learning period in Brazilian university students during the COVID-19 pandemic: A cluster analysis Burnout among primary care healthcare workers during the COVID-19 Pandemic We note that although the changes of parameters were statistically significant during the shift, they did not exceed the norm. Despite small physiological changes, most HCWs complained about the moderate discomfort of working in an FFP3/PPE, and they mainly complained about fatigue, thirst, and perspiration. We did not find any differences in the well-being parameters between the gender or age groups; additionally, there was no correlation between the SpO2 and HR and the well-being factors in the study workplace.We assume a 3-h shift rhythm -, i.e., three hours of working in the FFP3/PPE in the isolation ward (red zone), followed by rest or working without an FFP3/PPE (in positions that do not require them) is a safe and reliable solution. Data and materials are available on request to the corresponding authors. We would like to thank all the students for their participation in our study. We also wish to thank Andrzej Tomski, PhD, for his help in conducting the statistical analyses and Karolina Ostrowska, MA for the graphs preparation. I.W. and R.K. designed the study and wrote the manuscript. I.W., P.S., A.D., D.D. collected study data. Data management was performed by I.W., P.S., K.J., D.D. and R.K. I.W., R.K. and K.J. performed the statistical analyses. All authors contributed to critical revision of the final version of the manuscript for important intellectual content. All authors approved the final manuscript. The authors declare no competing interests. The online version contains supplementary material available at https:// doi. org/ 10. 1038/ s41598-022-05319-3.Correspondence and requests for materials should be addressed to R.K.Reprints and permissions information is available at www.nature.com/reprints.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.