key: cord-0973815-ujxdu0ar authors: Ruetalo, Natalia; Businger, Ramona; Schindler, Michael title: Rapid, dose-dependent and efficient inactivation of surface dried SARS-CoV-2 by 254 nm UV-C irradiation date: 2021-10-21 journal: Euro Surveill DOI: 10.2807/1560-7917.es.2021.26.42.2001718 sha: 9b42fb62809080b044e9de4b847c6f5fd58a6767 doc_id: 973815 cord_uid: ujxdu0ar Background: The COVID-19 pandemic urges for cheap, reliable, and rapid technologies for disinfection and decontamination. One frequently proposed method is ultraviolet (UV)-C irradiation. UV-C doses necessary to achieve inactivation of high-titre SARS-CoV-2 are poorly defined. Aim: We investigated whether short exposure of SARS-CoV-2 to UV-C irradiation sufficiently reduces viral infectivity and doses necessary to achieve an at least 6-log reduction in viral titres. Methods: Using a box and two handheld systems designed to decontaminate objects and surfaces, we evaluated the efficacy of 254 nm UV-C treatment to inactivate surface dried high-titre SARS-CoV-2. Results: Drying for 2 hours did not have a major impact on the infectivity of SARS-CoV-2, indicating that exhaled virus in droplets or aerosols stays infectious on surfaces for at least a certain amount of time. Short exposure of high titre surface dried virus (3–5*10^6 IU/ml) with UV-C light (16 mJ/cm(2)) resulted in a total inactivation of SARS-CoV-2. Dose-dependency experiments revealed that 3.5 mJ/cm(2) were still effective to achieve a > 6-log reduction in viral titres, whereas 1.75 mJ/cm(2) lowered infectivity only by one order of magnitude. Conclusions: SARS-CoV-2 is rapidly inactivated by relatively low doses of UV-C irradiation and the relationship between UV-C dose and log-viral titre reduction of surface residing SARS-CoV-2 is nonlinear. Our findings emphasize that it is necessary to assure sufficient and complete exposure of all relevant areas by integrated UV-C doses of at least 3.5 mJ/cm(2) at 254 nm. Altogether, UV-C treatment is an effective non-chemical option to decontaminate surfaces from high-titre infectious SARS-CoV-2. The severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has spread globally since January 2020 and there is an urgent need for rapid, highly efficient, environmentally friendly, and non-chemical disinfection procedures. Application of ultraviolet (UV)-C light is an established technology for decontamination of surfaces and aerosols [1] [2] [3] . This procedure has proven effective to inactivate SARS-CoV-1 [4] [5] [6] , several other enveloped and non-enveloped viruses as well as bacteria [7] . UV-C-based disinfection could be applied in operating rooms and healthcare facilities and it also proved useful in the business sector, where it is necessary to sterilise surfaces frequently touched by multiple individuals. Some examples discussed in the context of public health are escalators, public transportation, rental cars, door handles and waiting rooms. Recently, it has also been shown that SARS-CoV-2 is sensitive to inactivation by UV-C irradiation [8] [9] [10] [11] [12] . However, some of the studies used high UV-C doses from 108 mJ/cm 2 to more than 1 J/cm 2 at exposure times from 50 s to several minutes for total inactivation of SARS-CoV-2 [10] [11] [12] . These parameters are in a range complicating efficient application of UV-based methods for large-scale decontamination of surfaces and aerosols. Other studies used innovative 222 nm or 280 nm UV-C light-emitting diode (LED) technologies [8, 9] which are not yet implemented in most established 254 nm UV-C-based decontamination devices and needed relatively high doses of UV-C irradiation for inactivation. Another recent study by Storm et al. established 254 nm UV-C dose-dependency inactivation kinetics of SARS-CoV-2 and reported doses necessary for complete sterilisation of dry and wet virus preparations between 4 s and 9 s at 0.85 mW/cm 2 in a test box [13] . While these data are promising, a limitation of the study design was the use of a test box and relatively low viral titres which allowed for only 2-to 3-log titre reductions by the treatment. The exact knowledge about dose-dependent inactivation kinetics is essential to design UV-C-based decontamination procedures that allow definite disinfection of SARS-CoV-2. We hence conducted an approach simulating the inactivation of dried surface residing hightitre infectious SARS-CoV-2 by two mobile handheld (HH) UV-C emitting devices and an UV-C box designed to decontaminate medium-size objects. We investigated whether short exposure of SARS-CoV-2 to UV-C irradiation is sufficient to reduce viral infectivity and which UV-C doses are necessary to achieve an at least 6-log reduction in viral titres. Caco-2 (human colorectal adenocarcinoma) cells were cultured at 37 °C with 5% CO 2 in Dulbecco›s Modified Eagle Medium (DMEM) containing 10% fetal calf serum (FCS), with 2 mM l-glutamine, 100 μg/ml penicillin-streptomycin and 1% non-essential amino acids (NEAA). The recombinant SARS-CoV-2 expressing mNeonGreen (icSARS-CoV-2-mNG) [14] A total of 35 μl of virus stock, corresponding to ca 4-6*10 6 infectious units (IU) of icSARS-CoV-2-mNG were spotted (in triplicates) in 6-well plates and dried for 2 hours at room temperature (RT). This setup was chosen to mimic the situation in which an infected person exhales droplets that dry on surfaces and potentially stay infectious and hazardous over a prolonged period of time. Six-well plates spotted with dried virus were treated with UV-C-light (254 nm) using the Soluva pro UV Disinfection Chamber (Heraeus, Hanau, Germany) for 60 s or the Soluva Zone HP Disinfection Handheld (Heraeus) for 2 s in a fixed regime at 5 and 20 cm plate distance. In addition, a moving regime using slow (3.75 cm/s) and fast (12 cm/s) speed at 20 cm distance was tested. We also employed a second-generation Disinfection Handheld Soluva Zone H (Heraeus) which is less powerful than the Soluva pro UV but works autonomously with a rechargeable battery. The spectrum of UV-C lamps employed in these devices are shown in Supplemental figure 1. The lower UV-C intensity emitted by this device allowed us to perform a dosedependency experiment exposing dried virus with different UV-C intensities. The time-dependent UV-C intensity emitted by the Soluva Zone H at various distances is detailed and depicted in Supplemental figure 2. UV-C exposure was carried out after 10 min of preheating the device at a distance of 50 cm for 20 s, 10 s, 5 s, 2.5 s, 20 s + 97% UV-filter, 10 s + 97% UV-filter corresponding to 14 mJ/cm 2 , 7 mJ/cm 2 , 3.5 mJ/cm 2 , 1.75 mJ/cm 2 , 0.42 mJ/cm 2 and 0.21 mJ/cm 2 . These values are based on an on-site and parallel measurement of UV-C intensity emitted by the device via an UV-C dosimeter (Dr Gröbel UV electronic GmbH, Ettlingen, Germany), which corresponds to 0.7 mJ/cm 2 when the UV-C light is applied at 50 cm distance, and fits well to the previously company-measured value of 0.84 mJ/ cm 2 (Supplemental figure 2 ). As control, 6-well plates were spotted with the virus and dried, but not UV-C treated. After UV-C treatment, the spotted virus was reconstituted using 1 ml of infection media (culture media with 5% FCS) and viral titres determined as explained below. As additional control, 35 μl of the original virus stock were diluted to 1 ml with infection media and used as virus stock infection control. All UV-C treatments were done at RT. Experiments were repeated two to four times each, using duplicate or triplicate infections. GraphPad Prism 8.0 was used for statistical analyses (one-way ANOVA with multiple comparison and Fishers least significant difference (LSD)-test) and to generate graphs, as well as CorelDrawX7. Other software used included Gen5 v.3.10. This study does not include any data obtained with primary patient cells or data. Hence, there was no necessity to obtain ethical approval by the internal review board. Simulating the situation in which exhaled droplets or aerosols from infected individuals contaminate surfaces, we produced a high-titre SARS-CoV-2 infectious stock and dried 35µl of this stock corresponding to ca 4-6*10 6 IU/ml in each well of a 6-well plate. The plates were then either non-treated or exposed to five UV-C regimens at 254 nm (Figure 1a) . These include inactivation for 60 s in a box designed to disinfect medium-size objects, 2 s exposure at 5 cm or 20 cm distance with a HH UV-C disinfection device and an approach simulating decontamination of surfaces via the HH UV-C device (Zone HP). We performed this simulated HH decontamination in slow-and fast-moving speeds at a distance of ca 20 cm (Supplemental movie 1 and 2). UV-C irradiance (254 nm) in the box with an exposure time of 60 s corresponds to an irradiation dose of 600 mJ/cm 2 ; for the HH device, at 5 cm the UV-C dose at 2 s irradiation time is 80 mJ/cm 2 and at 20 cm is 16 mJ/cm 2 . From the speed of the slow and fast moving regimens we calculate a UV-C dose of 2.13 mJ/ cm 2 and 0.66 mJ/cm 2 , respectively, assuming a focused intensity beam. However, taking into consideration the UV-C light distribution underneath the HH device, the integrated UV-C dose accumulates to 20 mJ/cm 2 for the fast regimen. In the context of the moving fast regimen, even short UV-C treatment of the dried virus completely inactivated SARS-CoV-2. This was evident, as no infected cells were detected, when the dried virus was reconstituted in media and used to inoculate the naïve Caco-2 cells (Figure 1b) . Titration of twofold series dilutions of the UV-C treated and non-treated control samples, as well as the freshly thawed strain as reference, revealed that (i) drying for 2 hours does not have a major impact on the infectivity of SARS-CoV-2 and (ii) all five UV-C treatment regimens effectively inactivate SARS-CoV-2 ( Figure 1c) . Calculation of viral titres based on the titration of the reconstituted virus stocks revealed a loss of titre because of drying from ca 4*10 6 to ca 3*10 6 IU/ ml in this set of experiments and effective 6-log titre reduction of SARS-CoV-2 by all employed UV-C treatment regimens down to 16 mJ/cm 2 (Figure 1d ). We next aimed to determine the UV-C doses at 254 nm that are sufficient to achieve complete disinfection with an at least 6-log reduction in viral titres. For this, we employed a battery-driven UV-C HH device (Zone H) emitting 254 nm UV-C light at 0.7 mJ/cm 2 at a distance of 50 cm. This allowed us to treat surface dried SARS-CoV-2 with different UV-C doses by variation of the exposure time and additional use of a 97% UV-C filter. In agreement with our previous measurement, drying for 2 hours did not considerably affect SARS-CoV-2 infectivity and relatively high doses of 254 nm UV-C treatment (14 mJ/cm 2 ) inactivated SARS-CoV-2 ( Figure 2a exemplary images at 1:200 dilution and Figure 2b quantitative analyses). Furthermore, there was a dose-dependent reduction in SARS-CoV-2 infectivity with total inactivation down to 3.5 mJ/cm 2 while partial inactivation was still observed at 1.75 mJ/cm 2 (Figure 2a and b). Careful evaluation of viral titres post UV-C exposure revealed that > 6-log titre reduction was achieved by 3.5 mJ/cm 2 254 nm UV-C treatment (Figure 2c ). Of note, mean titres were only reduced by slightly more than one order of magnitude from 5.04*10 6 IU/ml of the dried and reconstituted SARS-CoV-2 to 3.5*10 5 IU/ ml when the virus was exposed to 1.75 mJ/cm 2 , corresponding to 93% inactivation. Therefore, the relationship between inactivation of surface dried SARS-CoV-2 and UV-C treatment is nonlinear, at least in our system, and 3.5 mJ/cm 2 are necessary to achieve a 6-log titre reduction. Disinfection of surfaces and aerosols by UV-C irradiation is an established, safe and non-chemical procedure used for the environmental control of pathogens [1] [2] [3] 15] . UV-C treatment has proven effective against several viruses including SARS-CoV-1 [4] [5] [6] and other coronaviruses, i.e. canine coronaviruses [16] . Hence, as recently demonstrated by others [8] [9] [10] [11] [12] [13] and now confirmed by our study, it was expected that SARS-CoV-2 can be inactivated by UV-C treatment. One critical question is the suitability of this technology in a setting in which the exposure time of surfaces or aerosols should be kept as short as possible to allow for a realistic application, such as in rooms that need to be used frequently as operating rooms or lecture halls. In such settings, we assume that the virus is exhaled from an infected person by droplets and/ or aerosols, dries on surfaces and hence represents a threat to non-infected individuals. We mimicked such a situation and first evaluated if surface dried SARS-CoV-2 is infectious. Drying for 2 hours, in agreement with previous work [13, 17] , did not result in a significant reduction of viral infectivity, indicating smearinfections could indeed play a role in the transmission of SARS-CoV-2. On the other hand, our virus-preparations are dried in cell culture pH-buffered medium containing FCS, which might stabilise viral particles. Hence, even though this is not the scope of the current study, it will be interesting to evaluate if longer drying or virus-preparations in PBS affect the environmental stability of SARS-CoV-2. Irrespective of the latter, UV-C-exposure of dried high-titre SARS-CoV-2 preparations containing ca 3-5*10 6 IU/ml after reconstitution resulted in a complete reduction of viral infectivity. In this context, it is noteworthy that we achieved a 6-log virus-titre reduction in a setting simulating surface disinfection with a moving handheld device. With our fast-moving protocol, the calculated integrated UV-C dose of 20 mJ/cm 2 at 254 nm, was substantially lower than the previously reported 1,048 mJ/cm 2 necessary to achieve a 6-log reduction in virus titres when exposing aqueous SARS-CoV-2 to UV-C [10] . In another study using a 222 nm UV-LED source, 3 mJ/cm 2 lead to a 2.51-log (99.7%) reduction of infectious SARS-CoV-2 when irradiating for 30 s; however, inactivation did not increase with extended irradiation regimens up to 300 s [9] . In addition, 20 s deep-ultraviolet treatment at 280 nm corresponding to a dose of 75 mJ/cm 2 reduced SARS-CoV-2 titre up to 3-logs [8] . Finally, Storm and colleagues reported a 2-log reduction of dried SARS-CoV-2 at 4 s with 0.85 mW/cm 2 corresponding to 3.4 mJ/cm 2 [13] . Of note, this value is highly similar to the dose of 3.5 mJ/cm 2 calculated by us to be sufficient to achieve a > 6-log SARS-CoV-2 titre reduction when the virus is in a dried surface residing state ( Figure 2 ). Comparing these values to other pathogens, SARS-CoV-2 seems particularly sensitive towards UV-C light. To achieve a 3-log titre reduction, 75-130 mJ/cm 2 are necessary for adenovirus, 11-28 mJ/cm 2 for poliovirus, and bacteria such as Bacillus subtilis require 18-61 mJ/ cm 2 [7] . Important limitations of UV-C-based disinfection procedures exist. First and most importantly, UV-C irradiation is harmful to humans because of the high energy of the germicidal lamps and exposure of skin or eyes must be avoided. This excludes decontamination of populated public spaces by UV-C. Furthermore, UV-C does not penetrate surfaces, hence for efficient disinfection, equal direct irradiation of all surfaces with a sufficient dose has to be assured. Our work highlights this aspect, as due to the nonlinear decay kinetic of the dose-response relationship, 3.5 mJ/cm 2 will totally inactivate high viral titres, whereas a slightly reduced dose of 1.75 mJ/cm 2 only achieves roughly one-log reduction (Figure 2c ). Apart from that, our study, as well as the research done by others [13] , emphasises UV-C-based disinfection technologies as highly efficient to rapidly sterilise surfaces in different settings such as operating rooms, less-frequently populated areas in healthcare facilities and public transportation, as well as in research facilities. Ideally, applications should be performed in closed containers, precluding exposure of persons to UV-C radiation when sterilising small to medium-size objects. The use of UV-C lamps in air sterilisers would have a strong impact on public health and prevent exposure of the public to infectious aerosols. Currently, we do not know if SARS-CoV-2 in aerosols is inactivated by similar doses and the transferability of our results to viral aerosols might be limited. Nevertheless, our results may give a first indication on further use, even though dynamics and inactivation kinetics of virus in aerosols might differ. Hence, it is highly relevant and warranted to conduct studies to carefully determine UV-C doses necessary and sufficient for inactivation of SARS-CoV-2 in aerosols. We established the effectiveness of UV-C treatment against SARS-CoV-2 in a setting designed to simulate close-to-reality conditions of decontamination. The easy, rapid and chemical-free application of UV-C treatment to inactivate SARS-CoV-2 and its high efficacy demonstrates the potential of this technology in a broad range of possible settings. This is an open-access article distributed under the terms of the Creative Commons Attribution (CC BY 4.0) Licence. You may share and adapt the material, but must give appropriate credit to the source, provide a link to the licence and indicate if changes were made. Effect of ultraviolet germicidal irradiation on viral aerosols Role of ultraviolet (UV) disinfection in infection control and environmental cleaning Role of Ultraviolet Disinfection in the Prevention of Surgical Site Infections Stability of SARS coronavirus in human specimens and environment and its sensitivity to heating and UV irradiation Large-scale preparation of UV-inactivated SARS coronavirus virions for vaccine antigen Inactivation of the coronavirus that induces severe acute respiratory syndrome, SARS-CoV UV Dose) Required to Achieve Incremental Log Inactivation of Bacteria, Protozoa, Viruses and Algae Rapid inactivation of SARS-CoV-2 with deep-UV LED irradiation Effectiveness of 222-nm ultraviolet light on disinfecting SARS-CoV-2 surface contamination Susceptibility of SARS-CoV-2 to UV irradiation Fast inactivation of SARS-CoV-2 by UV-C and ozone exposure on different materials UV-C (254 nm) lethal doses for SARS-CoV-2. Photodiagn Photodyn Ther Rapid and complete inactivation of SARS-CoV-2 by ultraviolet-C irradiation An infectious cDNA clone of SARS-CoV-2 No touch' technologies for environmental decontamination: focus on ultraviolet devices and hydrogen peroxide systems Canine coronavirus inactivation with physical and chemical agents Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1 We are thankful to Jan Winderlich, Jasmin Zahn, Christoph Söller, und Anika Hofmann (Heraeus) for fruitful discussions and for providing UV-C lamp spectra and UV-C dose emission measurements on the Soluva Zone H. Heraeus provided the devices and gave financial support for laboratory consumables. None of the authors received any remuneration or other financial gains. Heraeus was not involved in data interpretation or any decision to publish. NR and MS designed the experiments; NR performed the experiments with support from RB; NR, RB and MS analysed the data; NR and MS drafted the figures and wrote the manuscript; MS developed the manuscript to its final form; MS planned and supervised the study; all authors read, edited, and approved the final manuscript.Any supplementary material referenced in the article can be found in the online version.