key: cord-0971168-rdnlwmfu authors: Thachil, Jecko; Longstaff, Colin; Favaloro, Emmanuel J.; Lippi, Giuseppe; Urano, Tetsumei; Kim, Paul Y. title: The need for accurate D‐dimer reporting in COVID‐19: Communication from the ISTH SSC on Fibrinolysis date: 2020-06-11 journal: J Thromb Haemost DOI: 10.1111/jth.14956 sha: 901f6c5d5088d5ef9f65eb00f835def7ecc5f169 doc_id: 971168 cord_uid: rdnlwmfu The coronavirus disease 2019 (COVID‐19) pandemic continues to claim many lives across the world. In the attempts to identify a reliable prognostic indicator, marked elevation of D‐dimer has been a strong contender.(1,2) In many studies, D‐dimers have consistently been shown to be the most significant marker for illness severity and death risk prediction.(3,4) Despite the usefulness of this fibrinolytic marker, along with a recent letter by Gris et al.,(5) we note several problems across the medical literature with D‐dimer reporting creating confusion and potentially misleading data interpretation. The coronavirus disease 2019 (COVID-19) pandemic continues to claim many lives across the world. In the attempts to identify a reliable prognostic indicator, marked elevation of D-dimer has been a strong contender. 1, 2 In many studies, D-dimers have consistently been shown to be the most significant marker for illness severity and death risk prediction. 3, 4 Despite the usefulness of this fibrinolytic marker, along with a recent letter by Gris et al., 5 we note several problems across the medical literature with D-dimer reporting creating confusion and potentially misleading data interpretation. Since the arrival of the first monoclonal antibody-based assays in the 1980s, D-dimer measurements have consistently proven to be a reliable diagnostic tool. 6 Recent heightened awareness among the health care professionals and public about the risk of venous thromboembolism (VTE) and disseminated intravascular coagulation (DIC), coupled with ease of use and accessibility of the D-dimer tests led to its increased popularity. The increased demand has led to proliferation of commercially available assays, but the manufacturers and consequently workers publishing their work have not been consistent with the reporting mechanisms of laboratory data, thus leading to confusion and causing outright errors. These issues have been recurring themes in the D-dimer saga. In over two dozen COVID-19 related papers published involving D-dimer levels this year, we noted the following problems:  Most failed to identify the manufacturer or type of D-dimer assay used  Most did not clearly report the analytical performance of the assay (i.e. variations in sensitivity, specificity and linearity of the quantitation methods)  There was limited information on whether D-dimer units or fibrinogen equivalent units were used  There were inconsistencies in the magnitude of units chosen (e.g. mg/L or μg/mL or ng/mL)  A normal or disease specific cut-off value was not reported in some and most did not include age-related cut-offs  Distinction was typically not made between thromboembolism and DIC  The statistical analysis used for comparing data was often vague This article is protected by copyright. All rights reserved Plasmin degradation of cross-linked fibrin during fibrinolysis creates complex fragments, which contain D and E fragments. 7,8 A D-dimer refers to the covalently bound D-domains of adjacent fibrin monomers along with an E-domain of the opposite and staggered strand. Monoclonal antibodies to D-dimer were created in the 1980s, which were specific for epitopes on D-D fragments and absent on fibrinogen and non-cross-linked fibrin fragments. 9, 10 However, fragments released from proteolysis of fibrinogen and fibrin by elastase and other enzymes in the circulation could interfere with this test, especially in the setting of sepsis or inflammation (as commonplace in the COVID-19 scenario). 11 Since the different D-dimer assays use monoclonal antibodies to fibrin fragments, variability in test results between kits is very much possible. The Fibrin Assay Comparison Trial (FACT) study distributed a set of 86 samples from patients with different clinical conditions to 12 D-dimer manufacturers. 12 There were considerable variations in specificity for crosslinked fibrin in this study, possibly due to fibrin complexes, or fibrin degradation products (FDPs). 12 There are frequent reports of very high fibrinogen levels in COVID-19 patients and it is not know what effect this may have on D-dimer test performance. [13] [14] [15] High circulating fibrinogen, fibrinogen degradation products or changes in fibrin structure may all potentially affect test specificity and sensitivity. There are also issues with the specificity and sensitivity of the D-dimer assay based on the diagnostic purpose. A meta-analysis including 97 studies of patients with suspected deep vein thrombosis (DVT) reported an overall estimated sensitivity and specificity of D-dimer of 90.5% and 54.7%, respectively, but both estimates were subject to significant heterogeneity. 16 Sensitivity and specificity also varied across the different types of tests and the clinical probability for DVT. 16 For the diagnosis of DIC, D-dimer quantification is more crucial, where the variability can pose significant issues. 17 FDPs can also affect D-dimer causing over-or under-estimation of D-dimer. 18 The poor specificity of D-dimer tests leads to high rates of false positive results but reliable negative test results, and explains why D-dimer screening is commonly used to exclude DVT. One FEU compares the mass of the D-dimer to that of fibrinogen with a calibrator prepared from plasmin degradation of purified fibrinogen. 20,21 DDU is an estimated mass of the D-dimer unit with purified D-dimer used as the calibrator. 19, 21 FEU is approximately two-fold higher than that of DDU. If laboratory personnel or clinicians are not aware of this distinction, results This article is protected by copyright. All rights reserved interpretation can be inaccurate. Olson et al. performed a survey among several US laboratories and noted that almost a third of the laboratories changed the units from that recommended by the manufacturer. 20 Another web survey revealed that 28 different combinations of measure units are currently employed for reporting D-dimer test results. 22 Secondly, there is tremendous variability in the magnitude of units reported. Different publications use ng/mL, μg/mL, mg/L and μg/L to report D-dimer results which can cause considerable confusion among non-laboratory health care personnel. This heterogeneity in the reporting units was identified in the web-survey where a third each was using "ng/mL" and "mg/L", while 18% used "µg/L". 22 The problems with cut-offs D-dimer is commonly used to exclude VTE in patients with low clinical probability. A threshold or cut-off value is important for application of this exclusion. Once again, the D-dimer cut-off level is dependent on the different assay methods and calibrators. 19 D-dimer users should be aware that cut-off values are not transferable between methods and even between institutions. The assay should ideally be validated in prospective studies or at least compared with already validated assays. 20 The British Committee for Standards in Haematology (BCSH) guidelines state that testing a minimum of 200 subjects should be done before local approval of a D-dimer assay, 23 although this may be difficult to achieve in all laboratories. Prothrombin time used in patients receiving vitamin K antagonists was in similar turmoil as D-dimer. Collaborative efforts in this area led to development and widespread use of the International Normalised Ratio (INR). Similarly, our group has been investigating potential ways to generate standardization of D-dimer to help address current issues. The presence of different Ddimer fragments and patient characteristics makes preparation of a 'universal standard' not easy and straighfoward. 17, 18, 24 Harmonization rather than standardisation of test results may be a possible solution to this conundrum. 18, 25 Harmonization would involve conversion of D-dimer values from different assays to a common scale, by applying a validated conversion factor. 26 Major commitment of manufacturers is required to investigate kit performance in COVID-19 patients and develop new or updated methods if appropriate. This article is protected by copyright. All rights reserved Consistent elevation in D-dimer in all hospitalized patients with COVID-19 has led some clinicians to use this marker to decide on low intensity or high-intensity anticoagulation based on fold increase in D-dimers. 27 This approach is probably based on the presumption that all the Ddimers are coming from clot breakdown, which may not be the case in all patients. For the purpose of this communication, it is premature to confirm this is a safe strategy without evidence from randomised trials. Another clinical strategy is intensification of anticoagulation in patients who have increase in D-dimers despite prophylactic anticoagulation which again is presumptive and not yet proved to be a safe approach. 28 Lastly, some studies have already shown than decrease in D-dimers may signify the patient is improving and could mean downgrading the anticoagulation intensity. 29 This is certainly a novel use for D-dimer measurements but requires serial monitoring with an accurate method. Currently, there is no evidence to prove that findings with one D-dimer kit will necessarily translate to other D-dimer kits, and harmonisation will expectedly improve comparability. We can hence summarize here a set of indications that we recommend be used when reporting data on D-dimer testing, with special focus on studies in COVID-19, where D-dimer may evenly influence the clinical decision making.  The type of the of the D-dimer assay (name and manufacturer) must always be clearly reported  The minimal analytical performance of the assay (including at least the functional sensitivity, total imprecision, linearity and potential interference from FDPs) should be described  A standardized measuring units should be used for reporting data (FEU, as either "μg/L" or "mg/L")  The cut-off value used in the study should be clearly indicated  The statistical analysis should be appropriately selected according to sample size and value distribution (normal or not) All other authors have no conflict of interest to report. JT wrote the manuscript and CL, EJF, GL, TU, and PYK participated in discussion and critical editing of the manuscript. Abnormal coagulation parameters are associated with poor prognosis in patients with novel coronavirus pneumonia Anticoagulant treatment is associated with decreased mortality in severe coronavirus disease 2019 patients with coagulopathy D-dimer levels on admission to predict in-hospital mortality in patients with Covid-19 Acute Pulmonary Embolism in COVID-19 Patients on CT Angiography and Relationship to D-Dimer Levels Uncertainties on the prognostic value of D-dimers in COVID-19 patients Characterisation of a soluble D dimer-E complex in crosslinked fibrin digests Fibrin clot formation and lysis: basic mechanisms On soluble fibrinogen-fibrin complexes An immunoassay for human D dimer using monoclonal antibodies On behalf of the Subcommittee on Fibrinogen of the Scientific and Standardization Committee of the ISTH Degradation of cross-linked fibrin by human leukocyte proteases The Fibrin Assay Comparison Trial (FACT): evaluation of 23 quantitative Ddimer assays as basis for the development of D-dimer calibrators. FACT study group Abnormal coagulation parameters are associated with poor prognosis in patients with novel coronavirus pneumonia Prominent changes in blood coagulation of patients with SARS-CoV-2 infection Risk Factors Associated With Acute Respiratory Distress Syndrome and Death in Patients With Coronavirus Disease Variation in the diagnostic performance of Ddimer for suspected deep vein thrombosis Harmonisation of D-dimer -A call for action D-dimer: standardization versus harmonization An Overview of Hemostasis and Fibrinolysis, Assays, and Clinical Applications D-dimer: simple test, tough problems Plasma D-Dimer and Venous Thromboembolic Disease in Deep Vein Thrombosis and Pulmonary Embolism International survey on D-dimer test reporting: a call for standardization Haemostasis and Thrombosis Task Force of the British Committee for Standards in Haematology. The diagnosis of deep vein thrombosis in symptomatic outpatients and the potential for clinical assessment and D-dimer assays to reduce the need for diagnostic imaging Standardization of D-dimer Testing All rights reserved 25. Nieuwenhuizen W. A reference material for harmonisation of D-dimer assays. Fibrinogen Subcommittee of the Scientific and Standardization Committee of the International Society of Thrombosis and Haemostasis A model for the harmonisation of test results of different quantitative D-dimer methods Diagnosis, Prevention, and Treatment of Thromboembolic Complications in COVID-19: Report of the National Institute for Public Health of the Netherlands BTS Guidance on Venous Thromboembolic Disease in patients with COVID-19 accessed The procoagulant pattern of patients with COVID-19 acute respiratory distress syndrome Accepted Article