key: cord-0969897-w5je3ikb authors: Kobayashi, G. S.; Brito, L. A.; Moreira, D. D. P.; Suzuki, A. M.; Hsia, G. S. P.; Pimentel, L. F.; Barreto de Paiva, A. P.; Dias, C. R.; Lourenco, N. C. V.; Oliveira, B. A.; Manuli, E. R.; Corral, M. A.; Cavacana, N.; Neto, M. M.; Sales, M. M.; Dell' Aquila, L. P.; Filho, A. R.; Parrillo, E. F.; Mendes-Correa, M. C.; Sabino, E. C.; Costa, S. F.; Leal, F. E.; Sgro, G. G.; Farah, C. S.; Zatz, M.; Passos-Bueno, M. R. title: A novel RT-LAMP workflow for rapid salivary diagnostics of COVID-19 and effects of age, gender and time from symptom onset date: 2021-06-09 journal: nan DOI: 10.1101/2021.06.07.21258288 sha: b9ea141c3df8b6fa212a8f241c04a9548dbf463c doc_id: 969897 cord_uid: w5je3ikb Objectives: Rapid diagnostics is pivotal to curb SARS-CoV-2 transmission, and saliva has emerged as a practical alternative to naso/oropharyngeal (NOP) specimens. We aimed to develop a direct RT-LAMP workflow for viral detection in saliva, and to provide more information regarding its potential in COVID-19 diagnostics. Methods: Clinical and contrived specimens were used to screen/optimize formulations and sample processing protocols. Salivary viral load was determined in symptomatic patients to evaluate clinical performance (n = 90) and to characterize saliva based on age, gender and time from onset of symptoms (n = 49). Results: The devised workflow achieved 93.2% sensitivity, 97% specificity, and 0.895 Kappa for salivas containing >102 copies/L. Further analyses in saliva showed peak viral load in the first days of symptoms and lower viral loads in females, particularly among young individuals (<38 years). NOP RT-PCR data did not yield relevant associations. Conclusions: This novel saliva RT-LAMP workflow can be applied to point-of-care testing. This work reinforces that saliva better correlates with transmission dynamics than NOP specimens, and reveals gender differences that may reflect higher transmission by males. To maximize detection, testing should be done immediately after symptom onset, especially in females. pandemic has been crucial to monitor infection dynamics and prevent spread of the disease. The gold standard has been Real-Time Polymerase Chain Reaction (RT-PCR), which is performed on nasopharyngeal and oropharyngeal (NOP) specimens that pose discomfort to patients and require specialized materials and trained healthcare professionals for collection. In addition, RT-PCR typically requires viral inactivation followed by a lengthy RNA extraction/isolation step, further complicating diagnostic workflows and increasing turnaround time for reporting results. Faster and simplified protocols for viral detection are desirable to curb transmission, especially in point-of-care settings and places that lack infrastructure, access to material, or financial means. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) has emerged as a viable, affordable alternative to RT-PCR, since it allows rapid and direct detection of pathogens without nucleic acid extraction and sophisticated equipment (1) . Although SARS-CoV-2 is transmitted via infected saliva droplets and aerosols, attention has been focused on the upper airway tract rather than the oral cavity. Recently, viral shedding has been observed in the salivary glands and oral mucosa, further implicating saliva in infection and transmission (2) . Saliva has been considered a suitable alternative specimen for COVID-19 molecular diagnostics and to monitor viral spread, as it is easily accessible and can be collected by unsupervised patients into simple airtight vessels, diminishing costs and risk of transmission (3) . Implementation of salivary diagnostics must account for some issues, such as poor understanding of the viral biology in the oral cavity and viral load dynamics across individuals, which is important to determine the optimal test window to detect SARS-CoV-2. Furthermore, development of robust protocols for viral detection in saliva may be useful for diagnosis of other respiratory pathogens. Here, we describe a novel workflow for RT-LAMP-based detection of SARS-CoV-2 that includes an RNA stabilization solution to prepare saliva specimens without RNA isolation. This workflow stabilizes viral RNA, allows sample manipulation without biosafety rooms and cabins, and shows 93.2% sensitivity for viral loads above 10 2 μL of saliva, 97% specificity, and 0.895 Kappa coefficient. We also provide insights into viral load differences between saliva and NOP swab specimens and relate them to gender, age, and time from onset of symptoms, further elucidating the diagnostic performance of saliva and bringing forth recommendations to maximize chances of detection. This rapid and efficient workflow is suitable for COVID-19 diagnostics in both centralized or point-of-care settings, and may be of particular value for use in places lacking sophisticated infrastructure. females and 22 males -and 80 for the blind study -48 females and 32 males). Saliva samples were aliquoted locally and transported to our laboratory in dry ice, while NOP specimens were tested for SARS-CoV-2 by RT-PCR in each institution, which shared Ct results and clinical data whenever necessary. Briefly, individuals were asked not to eat for at least 30 minutes before collection of 3 mL of saliva in sterile, nuclease-free 15 mL conical tubes. Immediately post-collection, saliva was heat-inactivated by incubation at 95°C. We developed a solution (detailed information is described in the 'Results' section), . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted June 9, 2021. For real time analysis of RT-LAMP (rtRT-LAMP), the above reaction was supplemented with 1 μM SYTO ® -9 DNA binding dye (Thermo Fisher, #S34854) and 0.125 μL Low ROX reference dye (New England Biolabs, #E7638A), and incubated in a QuantStudio 5 qPCR machine (Thermofisher) at 65°C for 30 or 40 minutes (fluorescence signal acquisition at 15-second intervals), followed by a dissociation curve stage from 95°C to 60°C with temperature change rate of 0.1°C/second. To improve color discrimination, the reaction protocols above was further adjusted to contain 1.32x WarmStart ® Colorimetric LAMP Master Mix and 1 μL of DGS:saliva mixture in 2:1 ratio. Time to threshold (Tt) of positivity was defined at threshold = 0.8 relative fluorescence units. Each batch of reactions included positive controls with 1000 and 500 copies of SARS-CoV-2 RNA per reaction. Analysis of amplification plots and melting temperatures (Tm) were used to discriminate non-specific from specific amplifications (specific Tm = median Tm positive control ± 1ºC). SARS-CoV-2 RNA was isolated from crude saliva samples using QIAamp Viral RNA Mini Kit (QIAGEN, #52906), following manufacturer's recommendations. RT-PCR was performed based on CDC's protocol, which targets SARS-CoV-2 gene N (Centre for Disease Control and Prevention, 2020). RT-PCR reactions (12 μL total volume) contained TaqMan ® Fast Virus 1-Step Master Mix (Thermo Fisher, #4444432) and a primer/probe mix (500 nM forward primer, 500 nM reverse primer, 125 nM probe; 2019-nCoV_N1, IDT #10006600), and were cycled in a QuantStudio 5 qPCR machine as per manufacturer's recommendations (Thermo Fisher). Absolute quantification of viral RNA copies was performed via standard curve assays with 2019-nCoV_N_Positive Control (IDT, #10006625), in triplicates. SARS-CoV-2 RNA was isolated from cell culture pellets (kindly provided by collaborators from Instituto de Ciências Biomédicas, USP), and viral titer was determined via absolute quantification with RT-PCR, as described above. Quantified SARS-CoV-2 RNA was spiked into saliva from a healthy donor (previously processed with 2:1 ratio of DGS:saliva . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted June 9, 2021. ; https://doi.org/10.1101/2021.06.07.21258288 doi: medRxiv preprint and tested negative for SARS-CoV-2) to produce simulated specimens, and then stored in 10-µL aliquots at -80°C for further use in RT-LAMP reactions. Searching for a solution capable of stabilizing SARS-CoV-2 RNA in saliva, we initially screened 6 formulations containing Proteinase K (namely PK1-6). AVL, a commercial guanidine-based buffer recommended for SARS-CoV-2 inactivation (5), was used as the experimental control, without any heat treatment. Since unprotected viral RNA is rapidly degraded in crude saliva, we simulated samples by first mixing saliva from a healthy donor with the solutions (1:1, v/v) and heating at 65°C for 15 minutes followed by a step at 95°C for 2 minutes, before spiking in SARS-CoV-2 RNA. After sample processing, RNA was isolated and RT-PCR targeting the N gene was performed. We observed that PK6 led to similar Ct values to AVL (23.9 and 23.15, respectively), while no amplification was detected for the remaining PK formulations. Notably, PK6 and AVL were the only solutions that contained guanidine hydrochloride (GuHCl), suggesting that GuHCl is important for stabilizing the viral RNA. PK6 was composed of 800 mM GuHCl, 400 μg/mL PK, 10% Tween 20 (T20) and 30 mM Tris-HCl pH 8.0 (Table 1) . Aiming towards a minimal solution that enables RNA stabilization, several modifications were made to the PK6 formula. The removal of T20 and PK increased the Ct value in relation to AVL (ΔCt = 1.433), while no amplification was detected when substituting GuHCl with PK at a higher concentration (4 mg/mL), RNAse OUT (Thermo Fisher, #10777019) (6) or varying amounts of DTT (see below), further indicating that GuHCl is necessary to stabilize SARS-CoV-2 RNA in saliva (Fig. 1A) . By varying the amount of GuHCl in PK6 (1600 mM, 800 mM, 400 mM, 200 mM), we observed that viral RNA could be detected only when employing concentrations above 400 mM, and that 800 mM was sufficient for RNA stabilization (ΔCt ≤ 0.104) in the presence of T20 and PK (Fig. 1B) . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted June 9, 2021. ; Figure 1 . Modifications to the PK6 formula. A) Removal of PK and T20 increases Ct value, while substituting GuHCl with PK (4mg/mL), RNAse OUT or DTT results in no amplification. B) 800 mM GuHCl is sufficient to stabilize RNA in the presence of PK and T20. (*) The solution containing RNAse OUT was buffered by Tris-EDTA pH 8.0 instead of Tris-HCl (6) . C, D) Optimization of the stabilization solution. C) RNA stabilization is achieved by replacing PK and T20 with 200 mM DTT and reducing GuHCl to 600 mM, and (D) this is maintained after storage of processed specimens for 24 hours at 8°C. n.d. = not detected. Next, we examined whether DGS is compatible with direct RT-LAMP reactions. For this, we used saliva specimens from 3 individuals confirmed positive for COVID-19 via NOP swab RT-PCR by an external laboratory. In this test, specimens were heated with DGS under a slightly different protocol (55°C/15min followed by 95°C/2min) modified from previous work (7) . RT-LAMP was performed with the previously reported primer set N ( Table . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. S1) (8) and 10% volume of DGS:saliva (1:1) mix (total reaction volume = 12.5 μL), resulting in a 20-fold dilution of the DGS formulation (Table 2) . These 3 samples amplified specifically and changed color from pink to yellow within 30-40 minutes of reaction at 65°C, while the no-template controls (NTCs) remained pink ( Fig. 2A) , showing that DGS is compatible with colorimetric readouts. To characterize the effects of the DGS heat treatment on RT-LAMP, we performed . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; After 40-minute incubation at 65ºC, colors were visibly distinguishable between the pink NTC and the yellow positive samples. Agarose gel electrophoresis confirmed specific amplification, as band patterns of individuals 13717, 13713 and 13813) matched those of the positive control (10 4 RNA copies). Nonspecific amplification was observed in NTC after longer incubation (up to 60 minutes). B-F) Compatibility with direct rtRT-LAMP. B) SARS-CoV-2 RNA serially spiked in DGSsimulated saliva or in H 2 O was used to assemble standard curves for primer sets orf1ab, N, N1 and E, in duplicate reactions. Nonspecific and failed amplifications were observed at 0-120 copies/reaction in some reactions (not shown). Doubling time (DT) values were calculated to assess amplification speed/efficiency (11) for each primer set. Determination coefficients (r 2 ) point to high linearity (>0.939) between RNA input and Tt in DGS-simulated saliva, except for primer set N (r 2 = 0.8488). C) Representative color output after rtRT-LAMP (primer set E is shown). D) Representative dissociation analysis and gel electrophoresis showing non-specific LAMP products at 0 and 12 copies/reaction (primer set E is shown). NTC (no-template control) reactions were performed with H 2 O. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; https://doi.org/10.1101/2021.06.07.21258288 doi: medRxiv preprint The aforementioned protocols require mixing infected patient samples with DGS before viral inactivation, demanding high biosafety requirements. To overcome this issue, we sought to optimize sample processing to include a heat inactivation step before collection tubes were uncapped and further manipulated. As the starting point for comparison, we were maintained with DGS protocols B, C and D (Fig. 3D) . Moreover, these 3 DGS protocols showed no appreciable shifts in average Tt values after 24 hours at 8°C (Fig. 3E) , while at 30°C, this was only observed for protocol B (Fig. 3E') . Together, these results suggest that the 2-step protocol B is suitable to process clinical specimens, as it improves detection of SARS-CoV-2 compared to the no-DGS controls, and shows the most robust RNA stabilization effects. To further assess its performance in rtRT-LAMP, protocol B was applied to 11 additional COVID-19 clinical samples and compared to single heat inactivation without DGS (protocol A). rtRT-LAMP was performed in duplicates with primer set N1 and the humanspecific primer set ACTB (Table S1 ) (10) . In both methods, specific amplifications for ACTB were observed throughout all replicates, while specific amplifications for N1 were observed . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; https://doi.org/10.1101/2021.06.07.21258288 doi: medRxiv preprint in at least 1 out of 2 replicates in 9 samples. Differences in reaction speed (ΔTt) were calculated as average Tt Protocol B -Tt Protocol A . In 4 of these 9 samples, an important reduction in Tt values was observed for protocol B, varying from 3.5 to 9 minutes, while ACTB showed no significant Tt fluctuations (Fig. 3F ). This indicates that protocol B improves detection rates (Fig. 3A) and reaction speed (Fig. 3F) in clinical saliva, and suggests that the latter effect may be specific to SARS-CoV-2 detection, as ACTB showed low ΔTt variability. Finally, viral RNA was extracted from these 11 specimens and RT-PCR Ct values were used to estimate viral load. We observed that SARS-CoV-2 RNA was detected in all specimens with Ct < 30 (8/8), suggesting robustness for high viral loads (Fig. 3G) . is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; at 8°C and 30°C (n = 6). E, E') rtRT-LAMP results after storage at 8°C (E) and 30°C (E'). Data points above the dashed line are nonspecific amplifications. Results shown in D/E/E' were plotted with data from B (t = 0 hours). F-G) Assessment of protocol B in 11 additional specimens via rtRT-LAMP for primer sets N1 and ACTB. F) Changes in reaction speed of protocol B compared to A were plotted as ΔTt values; negative values indicate gain in reaction speed. Nonspecific and failed amplifications were not included. G) Saliva RT-PCR Ct values were plotted against Tt values used in F. Experiments in A-E were performed with n = 3 biological samples (P220031, P220032, and P220041 or P220051). All rtRT-LAMP reactions were carried out in duplicates. Since GuHCl was recently shown to improve speed and sensitivity of RT-LAMP (10), all rtRT-LAMP performed on no-DGS controls (protocol A) were supplemented with 40 mM GuHCl to allow more precise evaluation of the DGS protocols. We observed that up to 15% specimens showed discordant color output and amplification results after RT-LAMP followed by agarose gel electrophoresis (data not shown). This could be explained by pH variation of saliva or excess of salivary inhibitors impairing amplification efficiency. To ensure appropriate color-based analysis, volumetric adjustments were implemented in the DGS and RT-LAMP protocols. The DGS:saliva ratio was increased to 2:1 to enhance inactivation of salivary nucleases by DTT/GuHCl, while sample input into RT-LAMP reactions decreased from 1.25 µL to 1 µL and the volume of Colorimetric Master Mix increased from 6.25 µL to 8.25 µL (Table 3 ). These modifications resulted in better color discrimination after RT-LAMP, as color change and viral RNA amplification showed no discrepancies (Fig. 4A) . These adjustments were associated with a >95% limit of detection at 750 viral copies/µL in simulated specimens (Fig. 4B) . . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; https://doi.org/10.1101/2021.06.07.21258288 doi: medRxiv preprint To accelerate sample processing, we tested clinical saliva samples confirmed positive via RT-PCR, as better detailed in the next item. We simultaneously processed 29 positive specimens with the previously devised protocol (heat inactivation for 20 minutes at 95°C and DGS stabilization for 15 minutes at 55°C) and under shorter processing times (5 minutes at 95°C and 5 minutes at 55°C). Here, primer set N1 was replaced by E1, which is reported as more sensitive (12) (Table S1 ). Shortening both heat inactivation and DGS stabilization to 5 minutes led to the largest improvement in detection rate, enabling detection in 100% (14/14) of samples containing over 10 3 viral copies/μL and 67% (10/15) of samples below that cutoff, a 10-fold improvement over the unmodified protocol (Fig. 4C) . These results show that reducing sample processing time improves direct RT-LAMP sensitivity, particularly for low viral loads in saliva. To assess conservation of diagnostic properties, 8 of these DGS:saliva mixtures were stored at -80°C, thawed and analyzed via direct rtRT-LAMP, without consistent increments in Tt values. Considering that the processed specimens were freeze-thawed twice before this test, this suggests that DGS-processed saliva withstand repeated freezethaw cycles (Fig. 4D ). Following this, DGS:saliva mixtures were incubated at 8°C and 30°C for 36 hours. At 8°C, no consistent Tt increments were observed, while at 30°C, all samples showed increased Tt values, and one returned negative, suggesting that refrigeration is necessary to maintain diagnostic properties of specimens after processing (Fig. 4D') . . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; Representative color output before and after rtRT-LAMP performed on 4 clinical specimens and on 3000 and 1500 simulated viral copies/µL. B) Sensitivity using simulated specimens (20 replicates each). Notemplate control (NTC) reactions had H 2 O as input. C) Reduction of heat inactivation (HI) and DGS incubation times with respective rtRT-LAMP readout and sensitivity (stratified at 10 3 copies/μL; dashed line). D, D') Before-after plots for 8 specimens processed with HI for 5 minutes and DGS for 5 minutes. D) rtRT-LAMP Tt profiles after 1 freeze-thaw cycle. D') Tt profiles after storage for 36 hours at 8°C and 30°C. cp/μL = viral copies per μL of saliva. To evaluate the diagnostic performance of saliva, we analyzed 51 saliva samples These samples showed viral loads between 1.6 and 10 7 copies/µL of saliva (0.2-7 log 10 copies/µL; mean = 3.51, SD = 1.51) ( Fig. 5A; Table S2 ). No correlation between NOP swab . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; https://doi.org/10.1101/2021.06.07.21258288 doi: medRxiv preprint Ct values and viral copies in saliva was observed (Fig. 5B ). On average, Ct values in saliva were lower compared to NOP swabs (one-way ANOVA with Dunnet post-tests; p<0.05), indicating higher viral load in saliva (Fig. 5C ). Next, we analyzed viral load stratified by gender, time from onset of symptoms, and age (Table S2 ). These clinical data were available for 49 of the 51 individuals. Interestingly, males showed lower mean Ct values in saliva compared to NOP swabs, which was not observed for females (Fig. 5C') . Furthermore, males showed significantly higher viral loads in saliva than females (mean difference = 1.03 log 10 copies/µL; p = 0.032, Student's t-test) (Fig. 5D, D') , while no gender differences were found for NOP swab Ct values. In both male and female saliva, viral load peaked during the initial 2 days of symptoms and was negatively correlated with time (range = 2 to 10 days from onset of symptoms) (Fig. 5E ). Linear regression analysis showed that salivary viral load falls below 10 3 copies/µL at around (Fig. 5F ). Further, viral load in saliva was positively correlated with age in females, but not in males (range = 14-88 years) (Fig. 5G) . Notably, among younger patients (aged , females showed lower viral load than males, while no differences were observed in older individuals (aged 42-88), suggesting that the observed gender differences in salivary viral load decrease with age (Fig 5G') . In NOP swabs, no relationship was detected between viral load (Ct values) and age, gender or days since symptom onset ( Fig. 5H-K) . Together, these results show that saliva is a reliable diagnostic specimen in comparison to NOP swabs. Moreover, they show that viral load in saliva peaks in the early days of symptoms and is depleted with time, with young females displaying lower viral load compared to males. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; https://doi.org/10.1101/2021.06.07.21258288 doi: medRxiv preprint . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; Distribution of viral load in saliva from 51 COVID-19 patients. B) Pearson's correlation between viral load in saliva (gene N) and Ct values of NOP swab specimens (genes N and RdRp). C) Comparison of mean Ct values between saliva and NOP swab specimens; and C') the same analysis was performed for each gender. One-way ANOVA with Dunnet's posttests; *p<0.05; **p<0.001. D) Cumulative frequency distribution and D') comparison of mean viral loads between males and females; Student's t-test. E) Pearson's correlation between salivary viral load and days since onset of symptoms and F) the same analysis stratified by gender. Dashed lines or gray shading indicate 95% confidence intervals of the linear trends for significant correlations. G) Pearson's correlation between viral load and age for each gender. G') Comparison of mean viral loads between genders for younger (aged Without prior knowledge of NOP RT-PCR results, we tested 80 additional saliva samples from symptomatic individuals collected concomitantly with NOP swabs. Specimens were processed with the established DGS protocol. Direct rtRT-LAMP was carried out with primer sets N1, E1 and As1e, which was also reported to be more sensitive than N1 (Table S1 ) (12) , in addition to the human-specific primer set ACTB. All specimens showed successful amplification for ACTB, confirming adequate sample quality (data not shown). Reactions using E1 were performed in duplicates and results were considered positive upon detection in at least one of them, while single reactions were carried out with N1 and As1e. Nonspecific and failed amplifications were considered negative. RT-PCR in NOP specimens reported 51 positives (NOP + ) and 29 negatives (NOP -). Among the 51 NOP + individuals, saliva rtRT-LAMP returned positive in 40 with primer set E1, 35 with primer set As1e, and 31 with primer set N1, which was excluded from subsequent analyses due to reduced sensitivity and excessive nonspecific amplifications (Fig. 6A) . Joint analysis considering either E1 or As1e resulted in 41 positives and 10 negatives. RT-PCR on saliva from these 10 discordant NOP + individuals revealed either viral loads below 10 2 copies/µL or absence of SARS-CoV-2 (Fig. 6B) . Among the 29 NOPindividuals, joint E1/As1e analysis returned 4 positive salivas, which were confirmed in an independent rtRT-LAMP assay (data not shown). RT-PCR on saliva from these NOPindividuals detected SARS-CoV-2 at >10 2 copies/µL in 3 of the 4 E1/As1e positives. The remaining patients, negative in both NOP RT-PCR and saliva rtRT-LAMP, showed either undetectable (23/25) or low salivary viral load (<10 1 copies/µL; 2/25) . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; https://doi.org/10.1101/2021.06.07.21258288 doi: medRxiv preprint (Fig. 6B') . These results further highlight viral load disparities between NOP and saliva specimens, and indicate that a fraction of infected patients may escape detection via NOP To evaluate the diagnostic capabilities of our workflow, we tested a total of 90 salivas in which viral load was herein determined via RT-PCR, comprising 58 specimens confirmed positive and 33 specimens confirmed negative for SARS-CoV-2. These specimens had been processed with DGS and stored at -80°C. rtRT-LAMP reactions were carried out using E1 in duplicates and As1e in single reactions, as previously described. One positive sample failed to amplify ACTB likely due to low quality, and was excluded from the analysis (data not shown). rtRT-LAMP correctly identified 38/57 positive specimens with As1e and 44/57 in at least one of the E1 replicates, with the majority of specimens that escaped detection displaying viral loads below 10 2 copies/µL (Fig. 6C) . Notably, joint E1/As1e analysis also returned 44/57 positives since all 38 As1e-positives were covered by E1, suggesting little benefit from pairing E1 and As1e as presented. Considering the full range of viral loads represented here, this results in 77.2% overall sensitivity and 97% specificity (32/33 negatives) with primer set E1 or joint E1/As1e. Importantly, stratification at 10 2 copies/µL resulted in 93.2% sensitivity (41/44 positives) and Kappa = 0.895 for viral loads above this cutoff, demonstrating high sensitivity, specificity and reliability of the test (Fig. 6D) . Finally, we sought to determine the efficiency of the RT-LAMP color readout upon visual examination. Without prior knowledge of the results, the color output of 131 samples tested herein via rtRT-LAMP was visually classified as positive (yellow), negative (pink) or inconclusive (orange-shaded), for primer sets E1 and As1e. All yellow-and pink-colored reactions were correctly classified as positive and negative, respectively, resulting in 97.6% agreement for primer set E1 (206/211 reactions) and 97.7% agreement for primer set As1e (128/131 reactions). The orange-shaded output of the remaining reactions resulted from nonspecific or specific amplifications mostly with late Tt values in rtRT-LAMP, indicating absence of SARS-CoV-2 or low viral loads, respectively (Fig. 6E ). This demonstrates high agreement between endpoint color output and rtRT-LAMP analysis. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; Fig. 5 ). D) Assessment of sensitivity, specificity and Kappa values of rtRT-LAMP considering primer set E1 alone or E1/As1e for specimens containing at least 10 2 viral copies/µL (dashed line). E) Representative comparisons between visual color interpretation and rtRT-LAMP results (Tt values). Over 97.6% of specimens were correctly classified as positive (P, yellow) or negative (N, pink) for E1 and As1e, and the remaining was classified as inconclusive (I, orange-shaded). . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; In this work, we developed a DTT/GuHCl-based RNA stabilization solution (DGS) and a workflow that enables robust detection of SARS-CoV-2 in saliva via direct RT-LAMP, with either colorimetric or real-time fluorescence readout. We showed that heat treatment of saliva mixed with DGS protects SARS-CoV-2 RNA from degradation, while improving efficiency, reaction speed and detection rates during subsequent analysis by RT-LAMP. We also characterized saliva and NOP swab specimens according to viral load, gender, age, and time from symptom onset, providing more insight into the advantages and limitations of salivary SARS-CoV-2 diagnostics. In simulated saliva, we observed that heat treatment with PK-based formulations is insufficient to stabilize viral RNA, contrasting previous reports using samples containing SARS-CoV-2 virions (7, (13) (14) (15) . This discrepancy could be explained by the fact that the spiked RNA in our simulated samples is not protected by the nucleocapsid and other structural viral proteins, being readily digested by any active nucleases left after sample processing. This indicates that PK did not sufficiently inactivate salivary nucleases under the conditions examined here. Thus, care must be taken when using PK and other agents to process specimens, especially when combined with additional viral lysis methods, which may expose viral RNA to digestion. Accordingly, although SARS-CoV-2 remains stable in crude saliva (16) , diagnostic sensitivity may drop depending on the method employed to inactivate/process samples, such as heat inactivation, inclusion of detergents, and other factors (17, 18) , making the RNA protection provided by DGS nevertheless critical. In clinical saliva, DGS heat treatment improves detection of SARS-CoV-2 compared to heating without DGS. The active ingredients in DGS act by reducing and denaturing salivary extracellular ribonucleases and other inhibitors, and may also facilitate access of RT-LAMP enzymes to the SARS-CoV-2 genome through reduction and denaturation of viral proteins. GuHCl was recently reported to improve speed and sensitivity when added to RT-LAMP (10), so carryover of DGS into reactions may cooperate to increase SARS-CoV-2 detection by modulating reaction chemistry as well. Importantly, this carryover is not solely responsible for the rise in detection rates and reaction speed in clinical specimens, because these effects were observed in relation to no-DGS controls in which RT-LAMP was supplemented with GuHCl (40 mM). Thus, DGS improves SARS-CoV-2 detection both via stabilization of the viral genome and increasing RT-LAMP speed/sensitivity. Furthermore, DTT/GuHCl are also mucolytic agents (19) , and therefore ameliorate pipetting of viscous specimens. Of the DGS protocols investigated here, the best overall performance was achieved with a 2-step method that includes heat inactivation of the saliva in the collection vessel before further manipulation (protocol B). This protocol improved direct RT-LAMP speed and . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted June 9, 2021. ; https://doi.org/10.1101/2021.06.07.21258288 doi: medRxiv preprint detection rates compared to the no-DGS control, and elicited the strongest RNA stabilization effects compared to the other methods we examined. This 2-step protocol reduces risk of infection by healthcare specialists and clinicians since the collection vessel remains sealed until heat inactivation of the virus. Therefore, it facilitates diagnostic workflows and alleviates biosafety concerns in point-of-care settings and in test sites lacking in sophisticated infrastructure. Additional modifications to protocol B improved the diagnostic capabilities of the test. Color discrimination can be challenging due to interindividual variations in specimen quality, such as salivary pH. The volumetric adjustments to the DGS:saliva ratio and RT-LAMP mastermix improved endpoint color interpretation, while shortening the heat inactivation and DGS steps to 5 minutes each improved sensitivity for specimens containing less than 10 3 copies/µL, likely owing to greater RNA stability. These steps should suffice to inactivate SARS-CoV-2, since complete viral inactivation has been reported for periods as short as 3 minutes at 95°C (20, 21) . Furthermore, the final sample processing protocol is amenable to repeated freeze-thaw cycles and allows storage at 8°C for up to 36 hours without adversely affecting diagnostic output, which is important if RT-LAMP must be performed or repeated later. Finally, shortening sample processing time (from 35 to 10 minutes) further reduced diagnostic turnaround time. After these modifications, RT-LAMP achieved 77.2% overall clinical sensitivity and 97% specificity, with 93.2% sensitivity in saliva containing at least 10 2 viral copies/µL (Kappa = 0.895), which is on par or more sensitive compared to most of the direct RT-LAMP approaches reported so far (7, 12, (22) (23) (24) (25) (26) (27) (28) (29) (30) . Moreover, the high agreement (>97.6%) observed between color interpretation and specific amplification plots in rtRT-LAMP demonstrates reliability on end-point color readout if real-time analysis is not possible. Although only 23% of salivas containing less than 10 2 viral copies/µL were detected by the present method, the gain in exam turnaround time in the present method may be desirable at the cost of sensitivity, since lower viral loads are associated with lower transmissibility of SARS-CoV-2 (31) . Likewise, it has been proposed that effective COVID-19 surveillance depends on test frequency and turnaround time rather than on test sensitivity (32), especially for identifying nonsymptomatic carriers. Therefore, periodic testing using a faster, cheaper and noninvasive saliva protocol may be preferable to more lengthy and costly methods, such as standard RT-PCR workflows. Using RT-PCR, we detected SARS-CoV-2 in 94% of the salivas from symptomatic patients, with Ct comparisons suggesting that viral load in saliva may be higher than in NOP specimens, particularly in males. The observed absence of correlation between NOP and salivary viral load reflects distinct viral shedding dynamics in these tissues (2) . Our results confirm that saliva is a suitable diagnostic specimen compared to NOP swabs, especially in . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted June 9, 2021. ; https://doi.org/10.1101/2021.06.07.21258288 doi: medRxiv preprint cases where SARS-CoV-2 is present only in saliva, as ascertained in 3 patients herein. Male sex and old age are risk factors for developing severe COVID-19 (33, 34) . Here, males showed mean viral load around 10 times higher than females in saliva but not in NOP swabs. Since airborne transmission is related to the amount of virions per saliva droplet, this indicates that males could be more likely to spread the virus than females. Notably, compared to age-matched males, young females (< 38 years old) showed lower salivary viral load that increases with age, while no clear age-related effects were found in males. Clinical severity and immunological profiles seem to better correlate with viral load in saliva than in NOP swabs (35, 36) , so our findings could be attributed to distinct immune responses between genders leading to higher viral shedding and disease severity in males (37) , and could also explain the higher proportion of asymptomatic females in couples positive for SARS-CoV-2 (38) . These observations further suggest that salivary viral load together with older age, male gender and other risk factors could be important to predict disease duration, severity and mortality (36, 39) . Viral load in saliva peaked in the first days of symptoms and declined with time, agreeing with recent estimates that show peak transmissibility 1.8 days before onset of symptoms and low chance of transmission beyond 9.5 days after onset (40) . Importantly, we estimate that the sensitivity threshold of 10 3 copies/µL employed by several RT-LAMP approaches is crossed around the 5 th day of symptoms, with males showing delayed virus clearance compared to females. Based on these observations, we suggest that salivary diagnostics in symptomatic individuals should be performed as soon as possible after symptom onset to increase chances of detection, especially for young females. Recent reports show that saliva has higher sensitivity than nasal/nasopharyngeal swabs to identify asymptomatic cases (41) , and that viral load distribution is equivalent in saliva from symptomatic and nonsymptomatic individuals (42) . Therefore, rapid salivary diagnostics stands as an invaluable opportunity to efficiently monitor and curb SARS-CoV-2 transmission. In summary, we report a simple and rapid RT-LAMP diagnostic workflow that obviates the necessity of RNA extraction and specialized equipment, providing a cost-and time-efficient alternative to standard RT-PCR diagnostics. The use of DGS to process specimens and modifications to the RT-LAMP reaction resulted in high sensitivity and specificity to detect SARS-CoV-2 in saliva via real-time or endpoint colorimetric analysis, thus qualifying it for point-of-care testing. Our results not only confirm that saliva is a good diagnostic fluid, but also indicate that it may provide clues to clarify the biological determinants of SARS-CoV-2 infection and transmission. Finally, we reinforce that salivary diagnostics should be prioritized in screenings to identify presymptomatic and symptomatic cases of COVID-19, which may be extended to other respiratory pathogens. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted June 9, 2021. ; https://doi.org/10.1101/2021.06.07.21258288 doi: medRxiv preprint Loop-mediated isothermal amplification of DNA SARS-CoV-2 infection of the oral cavity and saliva Saliva as a diagnostic specimen for detection of SARS-CoV-2 in suspected patients: a scoping review Clinical features and natural history of the first 2073 suspected COVID-19 cases in the Corona São Caetano primary care programme: a prospective cohort study Assessment of inactivation procedures for SARS-CoV-2 Saliva-Based Molecular Testing for SARS-CoV-2 that Bypasses RNA Extraction Rapid and Extraction-Free Detection of SARS-CoV-2 from Saliva by Colorimetric Reverse-Transcription Loop-Mediated Isothermal Amplification CRISPR-Cas12-based detection of SARS-CoV-2 Rapid Detection of Novel Coronavirus (COVID-19) by Reverse Transcription-Loop-Mediated Isothermal Amplification. medRxiv Enhancing colorimetric loop-mediated isothermal amplification speed and sensitivity with guanidine chloride A novel approach for evaluating the performance of real time quantitative loop-mediated isothermal amplification-based methods. Biomolecular Detection and Quantification Optimizing direct RT-LAMP to detect transmissible SARS-CoV-2 from primary nasopharyngeal swab samples Pre-treatment of the clinical sample with Proteinase K allows detection of SARS-CoV-2 in the absence of RNA extraction A 5-min RNA preparation method for COVID-19 detection with RT-qPCR. medRxiv rapid and highly sensitive isothermal detection of SARS-CoV-2 for laboratory and home testing Simply saliva: stability of SARS-CoV-2 detection negates the need for expensive collection devices. medRxiv Analysis of Inactivation of SARS-CoV-2 by Specimen Transport Media, Nucleic Acid Extraction Reagents, Detergents, and Fixatives Molecular Diagnosis of COVID-19: Challenges and Research Needs Effect of mucolytic agents on the rheological properties of tracheal mucos Heat inactivation of the Severe Acute Respiratory Syndrome Coronavirus 2 The effect of heat-treatment on SARS-CoV-2 viability and detection Direct on-the-spot detection of SARS-CoV-2 in patients A Scalable Saliva-based, Extraction-free RT-LAMP Protocol for SARS-Cov-2 Diagnosis. medRxiv A simple direct RT-LAMP SARS-CoV-2 saliva diagnostic. medRxiv Development and evaluation of a rapid and simple diagnostic assay for COVID-19 based on loopmediated isothermal amplification A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples Direct diagnostic testing of SARS-CoV-2 without the need for prior RNA extraction. Sci Rep Extraction-free RT-LAMP to detect SARS-CoV-2 is less sensitive but highly specific compared to standard RT-PCR in 101 samples A highly effective reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay for the rapid detection of SARS-CoV-2 infection Clinical Assessment and Validation of a Rapid and Sensitive SARS-CoV-2 Test Using Reverse Transcription Loop-Mediated Isothermal Amplification Without the Need for RNA Extraction. Open Forum Infect Dis Transmission of COVID-19 in 282 clusters in Catalonia, Spain: a cohort study Test sensitivity is secondary to frequency and turnaround time for COVID-19 screening Male sex identified by global COVID-19 meta-analysis as a risk factor for death and ITU admission Is older age associated with COVID-19 mortality in the absence of other risk factors? General population cohort study of 470,034 participants Saliva viral load better correlates with clinical and immunological profiles in children with coronavirus disease 2019 Saliva viral load is a dynamic unifying correlate of COVID-19 severity and mortality. medRxiv Sex differences in immune responses that underlie COVID-19 disease outcomes Immunogenetics of resistance to SARS-CoV-2 infection in discordant couples Viral load dynamics and disease severity in patients infected with SARS-CoV-2 in Zhejiang province, China Infectivity, susceptibility, and risk factors associated with SARS-CoV-2 transmission under intensive contact tracing in Hunan, China Saliva is more sensitive than nasopharyngeal or nasal swabs for diagnosis of asymptomatic and mild COVID-19 infection. Sci Rep Just 2% of SARS-CoV-2-positive individuals carry 90% of the virus circulating in communities We are grateful to all patients who participated in this study, and we hope that you and yours can quickly recover from this challenging situation. We also thank all healthcare professionals, researchers and others combating the COVID-19 pandemic in Brazil. We thank Prof. Edison Durigon (ICB/USP) for providing inactivated SARS-CoV-2 virions and the staff at HUG-CELL and Instituto de Biociências/USP for enabling and supporting this work.Funding was provided by FAPESP (20/05949-2), FAPESP/CEPID (2013/08028-1), JBS, and Itaú-Saúde para Todos.