key: cord-0969188-do304245 authors: Gharoon, Niloufar; Dewan, Aimee; Li, Lin; Haak, Laura; Mazurowski, Lauren; Guarin, Tatiana; Pagilla, Krishna title: Removal of SARS‐CoV‐2 viral markers through a water reclamation facility date: 2021-10-03 journal: Water Environ Res DOI: 10.1002/wer.1641 sha: 344bf77cf6e1cc4cbfcf8fd195c55c876da17120 doc_id: 969188 cord_uid: do304245 ABSTRACT: There have been multiple reports of COVID‐19 virus, SARS‐CoV‐2 RNA presence in influent wastewater of water reclamation facilities (WRFs) across the world. In this study, the removal of SARS‐CoV‐2 RNA was investigated in a WRF by collecting samples from various stages relayed to hydraulic retention time (HRT) and analyzed for viral RNA (N1 and N2) gene markers and wastewater characteristics. SARS‐CoV‐2 RNA was detected in 28 out of 28 influent wastewater and primary effluent samples. Secondary effluent showed 4 out of 9 positive samples, and all tertiary and final effluent samples were below the detection limit for the viral markers. The reduction was significant (p value < 0.005, one‐way analysis of variance [ANOVA] test) in secondary treatment, ranging from 1.4 to 2.0 log(10) removal. Adjusted N1 viral marker had a positive correlation with total suspended solids, total Kjeldahl nitrogen, and ammonia concentrations (Spearman's ρ = 0.61, 0.67, and 0.53, respectively, p value < 0.05), while demonstrating a strongly negative correlation with HRT (Spearman's ρ = −0.58, p value < 0.01). PRACTITIONER POINTS: Viral RNA was present in all samples taken from influent and primary effluent of a WRF. SARS‐CoV‐2 gene marker was detected in secondary effluent in 4 out of 9 samples. Tertiary and final effluent samples tested nondetect for SARS‐CoV‐2 gene markers. Up to 0.5 and 2.0 log(10) virus removal values were achieved by primary and secondary treatment, respectively. The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is responsible for the current global pandemic of coronavirus disease . Belonging to the genus Betacoronavirus, SARS-CoV-2 is a positivesense single-stranded RNA virus (Chan et al., 2020; Lai et al., 2020; Zhu et al., 2020) . Multiple studies have reported the presence of SARS-CoV-2 in the feces of infected patients (Sun et al., 2020; Wang et al., 2020; Wu et al., 2020) . Subsequently, the presence of SARS-CoV-2 in untreated wastewater has been reported by many recent studies globally la Rosa et al., 2020; Medema et al., 2020) . However, the survivability and fate of the virus or virus markers during wastewater treatment have not been adequately investigated from full-scale water reclamation facilities (WRFs). While less is known about the fate of SARS-CoV-2 RNA through wastewater treatment systems, results from several studies have documented that temperature, biological activity, and wastewater matrix composition greatly influence the persistence of enveloped viruses in wastewater (Aquino de Carvalho et al., 2017; Bibby et al., 2015; Bivins et al., 2020; Casanova et al., 2009; Ye et al., 2016) . It is possible that wastewater matrix composition may affect virus persistence in WRFs as well. Matrices with higher organic content showed increased persistence of enveloped viruses, which has been attributed to viral aggregation to suspended particles, creating protection, and resulting in increased resistance to stressors (Aquino de Carvalho et al., 2017; Bibby et al., 2015) . Accordingly, it has been demonstrated that coronaviruses (CoVs), like feline infectious peritonitis virus (FIPV) and human coronavirus 229E (HCoV), persist longer in the unfiltered primary than unfiltered secondary treated wastewater; this was attributed to the protection level provided to virions by solids attachment from predation and inactivation (Gundy et al., 2009 ). While solid attachment may provide protection, this phenomenon could be beneficial for virus removal in the settling steps of a WRF, as primary and secondary treatment focus on the removal of total suspended solids (TSSs). Several studies report monitoring data for the presence of SARS-CoV-2 gene markers in both influent and effluent. Results demonstrated viral RNA presence in influent and nondetect in the effluent (Balboa et al., 2021; Haramoto et al., 2020; Randazzo et al., 2020; Rimoldi et al., 2020; Sherchan et al., 2020) . However, the presence of SARS-CoV-2 RNA varies for wastewater treatment processes, in a few studies that included monitoring throughout the treatment process train of a WRF, creating uncertainty on removal mechanisms for the virus. Although some variance can be attributed to nonoptimized virus concentration methods, there remains an information gap on the fate of SARS-CoV-2 RNA in the treatment stages of WRFs. Variance in positive results following primary treatment warrants further research to determine the routes of virus removal throughout different treatment processes. Therefore, the objectives of this study were to (1) monitor SARS-CoV-2 RNA at a WRF after different treatment stages; (2) determine which treatment process has the highest removal rates between primary, secondary, tertiary, and disinfection processes; and (3) determine the relation between wastewater characteristics and operating conditions and viral RNA removal. In this study, aside from centrifugal ultrafiltration, a two-step concentration method, hollow fiber ultrafiltration (HFUF) followed by polyethylene glycol (PEG) precipitation, was used for large volume samples grabbed from secondary, tertiary, and final effluent. This method was successful in SARS-CoV-2 RNA detection in the secondary treatment effluent samples. Wastewater and treated wastewater were collected after different treatment stages from a WRF in Washoe County, Nevada, USA, with the capacity of 167 Â 10 3 m 3 /day (44 million gallons per day [MGD] ) and an average operating flow rate of 114 Â 10 3 m 3 /day (30 MGD) during the study period. The WRF treatment train included screening, grit removal, primary sedimentation, secondary treatment with enhanced biological phosphorus removal (EBPR) activated sludge process, tertiary nitrification and denitrification, post aeration, sand filtration, and final disinfection using chlorine (Lacroix et al., 2020) . Samples were grabbed from five different process locations throughout the WRF daily from November 9 to November 22, 2020. As demonstrated in Figure 1 , locations are as follows: (1) primary influent (after grit removal), (2) primary effluent, (3) secondary effluent, (4) tertiary effluent, and (5) final effluent post chlorination. Grab samples were collected across all locations over a period of 2 weeks. HRTs for the treatment process were calculated to account for the daily flow rate. Sample collection at Location (1) began consistently between 9:45 a.m. and 10:30 a.m., and the final sample was taken 14-20 h after. It must be noted that the SARS-CoV-2 RNA gene signal may potentially depend on the grab versus composite sample type as a $10-fold increase in concentration was reported in the composite sampling of influent and primary effluent as relative to corresponding grab primary effluent samples (Gerrity et al., 2021) . In this study, for the purpose of following the wastewater through the facility based on the HRT values of each treatment process, grab sampling collection was performed. Influent (1) and primary effluent (2) samples were collected in 1-L sterile bottles; 10-L volume samples were collected for secondary (3), tertiary (4), and postdisinfection (5) effluent. Water temperature, pH, and dissolved oxygen (DO) measurements were measured on-site immediately during sampling. Samples were stored at 4 C and transported to the lab within 24 h for processing. Samples were processed to concentrate SARS-CoV-2 RNA gene markers within 3 days. Other water quality parameters such as total Kjeldahl nitrogen (TKN), TSS, total dissolved solids (TDSs), ultraviolet (UV) absorbance measurements at 254 nm (UVA 254 ), and dissolved organic carbon (DOC) were measured according to Standard Methods (APHA, 2018). Primary influent and effluent samples (Locations 1 and 2, shown in Figure 1 ) were concentrated using centrifugal ultrafiltration; 100 mL of a homogeneous mixture was centrifuged at 3000g for 15 min to remove particles and debris. Vacuum filtration was conducted on the supernatant using 1.5-μm filter paper (Whatman, Marlborough, MA, USA), 0.8-, and 0.45-μm membrane filters (Merck Millipore, Burlington, MA, USA) in sequence. A total of 30 mL of the resulting wastewater sample was concentrated by a 100-kDa Amicon ® Ultra-15 Centrifugal Filter Cartridge Units (Millipore Sigma, St. Louis, MO, USA) and centrifuged at 3500g until 200-300 μL was maintained in the filter. Samples were refrigerated until RNA extraction within 48 h. Considering the possible low presence of SARS-CoV-2 in secondary, tertiary, and final effluent sampling, this study used a two-step concentration method, combining HFUF and PEG precipitation, to process large volumes of those samples to enrich more. First, it is necessary to remove excess particles in the samples (Locations 3-5, shown in Figure 1 ). The samples were filtered by 1.5-μm membranes. Subsequently, samples were recovered by HFUF (REXEED-25S, 30 kDa, Asahi Kasei Medical Co., Japan). First, the sterile blocking buffer (0.1 g of sodium hexametaphosphate in 1-L reagent grade water) was passed through the filter from the inlet (top cap) to the outlet (bottom cap) and then $10-L samples were filtered. Next, 100 mL of ultrafiltration elution buffer (0.1 g of hexametaphosphate, 5 mL of Tween 80, and 10 μL of Antifoam A in 1-L reagent grade water) was cycled through the filter to elute the virus and protein particles for 5 min. Finally, the concentrated sample was collected into a sterile 250-mL bottle. Concentrated HFUF volumes of 65-195 mL were further processed using 8% PEG 8000 (v/v) and 3% 3-M NaCl (v/v) for precipitation. The mixture was refrigerated at 4 C and shaken slightly for 18 h. To collect the pellet, the mixture was centrifuged at 6700g for 30 min at 4 C. The supernatant was discarded, and the resultant pellet was resuspended in 5-mL TRIzol (Thermo Fisher Scientific, Carlsbad, CA, USA) and vortexed until fully dissolved. Samples were aliquoted into 2-mL tubes and then stored at À80 C until RNA extraction. Total RNA was extracted by the AllPrep PowerViral DNA/RNA kit (QIAGEN, Inc., Germantown, MD, USA) according to the provided user's manual. To quantify SARS-CoV-2 RNA, quantitative reverse transcription F I G U R E 1 Schematic diagram of wastewater treatment in the water reclamation facility (WRF). Sample locations as labeled: (1) primary influent, (2) primary effluent, (3) secondary effluent, (4) tertiary effluent, and (5) final effluent post chlorination; average sampling time based on daily hydraulic retention time (HRT) at each location polymerase chain reaction (RT-qPCR) methods were used. RT-qPCR assay used N1 and N2 primers and probes as per the Centers for Disease Control and Prevention (CDC) protocol (Centers for Disease Control and Prevention, 2020, Table S1 ). RT-qPCR runs were conducted using 5 μL of Reliance One-Step Multiplex Supermix (BioRad, Hercules, CA, USA); 0.4 μL of each forward, reverse primer, and probe; 8.8 μL of RNase-free water; and 5 μL of RNA template for a final volume of 20 μL in each reaction. RT-qPCR was conducted by the CFX96 Touch Real-Time PCR Detection System (BioRad, Hercules, CA, USA). The PCR conditions were as follows: initial 10 min at 50 C for reverse transcription, initial denaturing for 10 s at 95 C followed by 48 cycles of 3 s at 95 C for denaturation, 30 s at 55 C for annealing, and a final 30 s at 75 C for probe amplification. Positive and nontemplate controls (NTCs) were developed for every qPCR assay. For all calibration curves, correlation coefficients (R 2 ) > 0.99 were obtained with amplification efficiencies of 90-110%. Due to the similar enveloped structure with SARS-CoV-2, human coronavirus OC43 strain (HCoV-OC43) was used as a surrogate to investigate the SARS-CoV-2 recovery rate in the concentration methods. In this study, 40-to 100-μL HCoV-OC43 strain was spiked into samples and then the same concentration method of Amicon ultrafiltration and HFUF and PEG was conducted. The quantification of HCoV-OC43 was done according to the method by Uppal et al. (2021) . RT-qPCR assay used OC43-SF 5 0 -GGCTTATGTGGCCCCTTACT-3 0 and OC43-SR 5 0 -GGCAAATCTGCCCAAGAATA-3 0 primer set (for more details, see Tables S5 and S6 ). The recovery rate was calculated according to Equation 1. The impact of potential PCR inhibitors in the RNA extracts from the wastewater samples was investigated. In this study, all the RNA elutions have been diluted by À10and À100-folds, and the difference of Ct values of OC43 was determined, respectively Pei et al., 2006) . Additionally, internal amplification control The relationship between viral RNA concentrations and the sample's metadata was assessed by calculating Spearman's rho correlation coefficients. All the data were standardized by calculating zero scores to remove the individual variable's bias. To minimize the impact of nondetect data, the analysis included only the data concerning the influent and primary effluent samples in addition to secondary samples from the second week. The remaining nondetect values were replaced with the half of the detection limit to calculate the rho correlation coefficient. To compare the virus RNA removal between each treatment process, one-way analysis of variance (ANOVA) analysis was performed. The analysis was done by different approaches to establish the sensitivity of the results to different methods of handling the nondetect data that included substitution with detection limit, half of the detection limit (Farnham et al., 2002; Poma et al., 2019) or applying the rank-sum method according to Helsel (2011) . Before performing any analyses, all the data were adjusted based on the recovery efficiency of the method. The average recovery efficiency of HCoV-OC43 in the ultrafiltration method used for primary influent and effluent samples was 18% ± 7%. The recovery for HFUF followed by PEG precipitation used for secondary samples was found out to be 7% ± 5%. Because there were no positive results for tertiary and final effluent samples, only the secondary samples were spiked. While measuring the recovery efficiency of the spiked virus is needed to adjust the data for virus RNA removal comparison through the different processes of the WRF, it has been reported that recovery efficiencies for a certain method could vary depending on the sample type, type and concentration of the spiked virus, and chemical characteristics of wastewater (Kantor et al., 2021) . Therefore, the originally measured concentration data have been reported alongside the adjusted data based on the recovery values rather than reporting the latter only. According to the amplification of PMMoV, Ct values fell in the range of 23.1-37.7, which means the methods used were reliable to recover viruses in wastewater (Table S7) . Regarding inhibitor detection, all ΔCt values between À10and À100-fold dilutions were in the range between 3.2 and 4.0. Moreover, the IAC Ct values ranged from 24.4 to 25.3 (Table S7) . No RT-qPCR inhibitor has been identified. All 14 of the influent samples tested positive, as shown in Tables 1 and S2. In this study, the concentration for SARS-CoV-2 RNA markers measured in WRF influent ranged from 4.56 Â 10 4 to 4.31 Â 10 5 gc/L (adjusted values: 2.54 Â 10 5 -2.4 Â 10 6 gc/L). Primary effluent samples reported positive (14 out of 14) for both N1 and N2 genes where the concentration for N1 and N2 ranged from 4.0 Â 10 4 to 9.21 Â 10 5 gc/L (adjusted values: 2.22 Â 10 5 -5.12 Â 10 6 gc/L). Out of all the samples taken from secondary, tertiary, and final effluent, only four positive results were found for the secondary effluent samples. Concentration values for N1 and N2 ranged from 7.58 Â 10 2 to 2.36 Â 10 3 gc/L (adjusted values: 1.08 Â 10 4 -3.36 Â 10 4 gc/L). The adjusted values based on per cent recovery for each sample are shown in Table S3 . No viral RNA concentrations were detected in tertiary or final effluent samples, indicating the effectiveness of these treatment processes in eliminating the virus marker signal. Fate and removal of SARS-CoV-2 RNA in the WRF Partial virus removal occurred during the 2.7-h average HRT of primary treatment at the WRF. Because there was no significant difference (one-way ANOVA test; p value = 0.396) in SARS-CoV-2 RNA (gc/L) between the influent and primary effluent samples, the primary treatment is not considered a critical step of SARS-CoV-2 removal. After primary treatment, the wastewater went through the EBPR treatment. More than 96% (1.56 log 10 ) removal was observed between primary and secondary effluent. It must be noted that the quantified data have been adjusted based on the recovery efficiencies to calculate the log reduction value. The reductions of the N1 gene after primary and secondary treatment are visualized in Figure 2 . To better address the nondetect data, the comparison of the two groups was performed under multiple approaches, including assuming the detection limit and half of the detection limit for the nondetect value and using the rank-sum method to rank the data before the analysis. A significant removal (p value < 0.005) can be seen at secondary treatment compared with influent or primary effluent samples for the N1 gene, under all circumstances. The removal rates following secondary treatment suggest that secondary treatment plays a pivotal role in viral removal. SARS-CoV sorption to organic matter and flocs can be a removal mechanism during secondary treatment (Bogler et al., 2020; Chaudhry et al., 2015 (Gundy et al., 2009; Lon et al., 2020; Mohapatra et al., 2020) . Ye et al. (2016) reported that enveloped viruses behave according to a noninstantaneous quasi-equilibrium adsorption kinetic model in wastewater, where adsorption to solids will reach an equilibrium state but not instantly. Results showed up to 26% viral adsorption (or reduction in the liquid phase) when equilibrium is reached with TSS of 235 mg/L or medium-strength municipal wastewater. Kocamemi et al. (2020) confirmed the presence of SARS-CoV-2 RNA in 9 out of 9 sludge samples. Considering the high removals seen in this study across the aeration tank, additional factors may contribute to SARS-CoV-2 RNA removal in secondary treatment. Previous studies demonstrated that microbial predation and the action of proteases and nucleases could contribute to virus removal in secondary treatment (Bogler et al., 2020; Chaudhry et al., 2015; Gundy et al., 2009; John & Rose, 2005; Lv et al., 2006) . Viral RNA concentrations are consistently shown to decrease with increasing bacteria concentrations, especially floc forming strains (Deng et al., 2014; Kim & Unno, 1996; Olive et al., 2020) . The retention time was taken into consideration, with optimal timelines for both solid adsorption and microbial predation averaging an hour. Ye et al. (2016) found 99% equilibrium conditions were reached in 0.4-2.9 h, while 90% equilibrium concentrations occurred after only 0.3-1.5 h. In this study, HRT for secondary treatment at the WRF was about three times the primary treatment, averaging 8-9 h. The longer retention time, in combination with increased opportunities for solid phase adsorption and microbial predation, could likely be the mechanisms for the significant removal of SARS-CoV-2 RNA in secondary treatment in this study. Tertiary and final effluent samples that were tested during the 14-day sampling period returned nondetect results of SARS-CoV-2 genetic material. These results demonstrated efficient removal of the SARS-CoV-2 RNA by wastewater treatment at the WRF using chlorination as a final disinfection method. These results, as well as similar reports and recommendations by the World Health Organization (WHO), suggested that chlorinebased disinfectants were effective against enveloped viruses and SARS-CoV-2 (Collivignarelli et al., 2020; Saawarn & Hait, 2021; WHO, 2020) . Meanwhile, an organic matter covered SARS-CoV-2 may be more resistant to oxidation damage from chlorination (Bogler et al., 2020; Geller et al., 2012; Gundy et al., 2009; Ye et al., 2016) . Zhang et al. (2020) reported a high level of SARS-CoV-2 genetic material, (0.5-18.7) Â 10 3 gc/L, in hospital wastewater after disinfection with sodium hypochlorite, indicating the need to evaluate concentration dose and contact time. The effluent showed nondetect results for SARS-CoV-2 viral RNA after being overdosed with sodium hypochlorite, but high levels of disinfection by-products were reported, as expected. These analyses indicated that although chlorination can be a necessary step in virus removal, supporting secondary treatment as the main step in virus removal could help mitigate the reliance on the chlorination process. Consequently, there was no indication that current disinfection doses should be adjusted to remove any remaining viral load after secondary treatment. Spearman correlation was used to highlight the environmental and operational characteristics that had the strongest correlation with N1 in the WRF samples. Parameters such as TSS, TKN, ammonia, DOC, UVA 254 , and HRT were used in the analysis. By calculating the Spearman coefficients (Table S4) , adjusted N1 was seen to be strongly correlated with TKN (Spearman's ρ = 0.667, p < 0.0005), TSS (Spearman's ρ = 0.609, p < 0.0005), ammonia (Spearman's F I G U R E 2 Box plot demonstrating concentration reductions of SARS-CoV-2 N1 gene after sample locations (1) influent, (2) primary effluent, and (3) secondary effluent ρ = 0.528, p = 0.002), and HRT (Spearman's ρ = À0.577, p = 0.001) and correlated with DOC (Spearman's ρ = 0.414, p = 0.019) and UVA 254 (Spearman's ρ = 0.401, p = 0.023). However, there was no correlation between adjusted N1 and TDS (Spearman's ρ = 0.111, p = 0.545). These results identified that N1 removal had the strongest correlation to HRT and nutrient parameters associated with secondary biological treatment. The correlation with TSS was consistent with the understanding of the hydrophobicity of the envelope of SARS-CoV-2, which likely contributed to a tendency of the virus to attach to the other hydrophobic solids in wastewater, indicating viral removal by settling of solids (Bogler et al., 2020; Mohapatra et al., 2020) . The COVID-19 pandemic highlighted the importance of determining the fate of SARS-CoV-2 across a WRF. In this study, the objective was addressed by sampling at different stages of the WRF based on the HRTs of each treatment step. The presence of viral RNA was confirmed in all samples taken from influent and primary effluent. Viral RNA removal was found out to be not significant after primary treatment (p value = 0.396). However, secondary treatment showed significant removal (p value < 0.005) of SARS-CoV-2 RNA. Up to 2.0 log 10 removal value was achieved during secondary treatment. A lack of positive detection at tertiary treatment and final effluent stages confirmed the effectiveness of the combined tertiary nitrification/denitrification and filtration/chlorine disinfection to inactivate further and/or remove the SARS-CoV-2 RNA concentration to nondetectable levels. The total log 10 SARS-CoV-2 RNA removal level from influent to secondary treated water ranged from 1.5-1.8 during the monitoring period. Even though a few samples were found to be positive after the secondary treatment step, the fact that the current treatment train was capable of removing the viral markers to a nondetect level provides confidence not only to the WRF personnel but also to the public regarding the effectiveness and control of SARS-CoV-2 markers by water reclamation for environmental discharge. Calculating the Spearman's rho correlation coefficients demonstrated that adjusted N1 was positively correlated with TKN, TSS, ammonia, DOC, and UVA 254 and negatively correlated with HRT (p value < 0.05). Considering the hydrophobicity of the SARS-CoV-2 envelope and the correlation between adjusted N1 and TSS, there is a need to examine SARS-CoV-2 removal in liquid and solid phases of the biological treatment process further, as its effectiveness could mitigate any reliance on chlorination. First confirmed detection of SARS-CoV-2 in untreated wastewater in Australia: A proof of concept for the wastewater surveillance of COVID-19 in the community Standard Methods for the Examination of Water and Wastewater Evaluation of Phi6 persistence and suitability as an enveloped virus surrogate The fate of SARS-COV-2 in WWTPS points out the sludge line as a suitable spot for detection of COVID-19 Persistence of Ebola virus in sterilized wastewater Persistence of SARS-CoV-2 in water and wastewater Rethinking wastewater risks and monitoring in light of the COVID-19 pandemic Survival of surrogate coronaviruses in water Centers for Disease Control and Prevention. (2020) 2019-novel coronavirus (2019-nCoV) real-time rRT-PCR panel primers and probes Genomic characterization of the 2019 novel human-pathogenic coronavirus isolated from a patient with atypical pneumonia after visiting Wuhan Mechanisms of pathogenic virus removal in a full-scale membrane bioreactor SARS-CoV-2 in sewer systems and connected facilities. Process Safety and Environmental Protection Grazing of heterotrophic flagellates on viruses is driven by feeding behaviour Treatment of nondetects in multivariate analysis of groundwater geochemistry data Human coronaviruses: Insights into environmental resistance and its influence on the development of new antiseptic strategies Early-pandemic wastewater surveillance of SARS-CoV-2 in Southern Nevada: Methodology, occurrence, and incidence/prevalence considerations Survival of coronaviruses in water and wastewater First environmental surveillance for the presence of SARS-CoV-2 RNA in wastewater and river water in Japan. The Science of the Total Environment Statistics for Censored Environmental Data Using Minitab and R Review of factors affecting microbial survival in groundwater Challenges in measuring the recovery of SARS-CoV-2 from wastewater The roles of microbes in the removal and inactivation of viruses in a biological wastewater treatment system SARS-CoV-2 detection in Istanbul wastewater treatment plant sludges First detection of SARS-CoV-2 in untreated wastewaters in Italy Full-scale N removal from centrate using a sidestream process with a mainstream carbon source Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and coronavirus disease-2019 (COVID-19): The epidemic and the challenges Density-based separation of microbial functional groups in activated sludge Prediction and evolution of B cell epitopes of surface protein in SARS-CoV-2 Genomic characterisation and epidemiology of 2019 novel coronavirus: Implications for virus origins and receptor binding Virus removal performance and mechanism of a submerged membrane bioreactor Presence of SARS-Coronavirus-2 RNA in sewage and correlation with reported COVID-19 prevalence in the early stage of the epidemic in the Netherlands The novel SARS-CoV-2 pandemic: Possible environmental transmission, detection, persistence and fate during wastewater and water treatment Control of waterborne human viruses by indigenous bacteria and protists is influenced by temperature, virus type, and microbial species Effect of river landscape on the sediment concentrations of antibiotics and corresponding antibiotic resistance genes (ARG) Data fitting approach more critical than exposure scenarios and treatment of censored data for quantitative microbial risk assessment SARS-CoV-2 RNA in wastewater anticipated COVID-19 occurrence in a low prevalence area Presence and infectivity of SARS-CoV-2 virus in wastewaters and rivers Occurrence, fate, and removal of SARS-CoV-2 in wastewater: Current knowledge and future perspectives First detection of SARS-CoV-2 RNA in wastewater in North America: A study in Louisiana, USA Isolation of infectious SARS-CoV-2 from urine of a COVID-19 patient Inactivation of human coronavirus by FATHHOME's dry sanitizer device: Rapid and eco-friendly ozone-based disinfection of SARS-CoV-2. Pathogens Detection of SARS-CoV-2 in different types of clinical specimens Water, sanitation, hygiene and waste management for COVID-19, Interim Guidance. COVID-19 Infection Prevention and Control Prolonged presence of SARS-CoV-2 viral RNA in faecal samples Survivability, partitioning, and recovery of enveloped viruses in untreated municipal wastewater Potential spreading risks and disinfection challenges of medical wastewater by the presence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viral RNA in septic tanks of Fangcang Hospital A novel coronavirus from patients with pneumonia in China Removal of SARS-CoV-2 viral markers through a water reclamation facility The research reported in this paper has been funded by the City of Sparks with funds from the CARES Act. Casey Mentzer, John Martini, and Michael Drinkwater from the City of Sparks are gratefully acknowledged for their support and access to facilities to conduct this research.