key: cord-0968642-2suwypzr authors: NagataCavalheiro, Mariana; Fonseca, Vinicius Ribas; Zeigelboim, Bianca Simone; Costa, Diego F.; de Lima, Lucas Viomar; Bozzo, Marlon Kleber; Tonochi, Rita de Cássia; Hartmann, Bruno Ceron title: EVALUATING THE QUALITY OF RIGID OPTIC VIDEOLARYNGOSCOPY IMAGE TAKEN THROUGH DENTAL PROTECTION CAP AND ITS FEASIBILITY AS ADDITIONAL BARRIER METHOD AGAINST COVID-19 date: 2020-11-02 journal: J Voice DOI: 10.1016/j.jvoice.2020.10.014 sha: 4c0d2f5310feb6059104b7e24fa0e80c7cbd5093 doc_id: 968642 cord_uid: 2suwypzr Videolaryngoscopyscreening is essential to help assessing human larynx. The use of 70° optical fiber in association with image recording by analog or digital cameras is one of the methods adopted to perform this examination. Endoscopic exams can contaminate the equipment with several microorganisms.The pandemic caused by the new coronavirus (SARS-CoV-2) reinforces the importance of developing efficient barrier methods to be adopted in videolaryngoscopy procedures. Although dental intraoral camera covers are a barrier method authorized by Brazilian health organs, it has not yet been used in videolaryngoscopy examinations. The aim of the current longitudinal, individualized, single-blind, prospective, self-controlled and accurate study is to evaluatethe quality of images generated through, and confidence level of,diagnosis based on videolaryngoscopyperformed with intraoral dental camera equipped with disposableprotection cap and connected to 70° rigid laryngoscope in vocally healthy individuals.Videolaryngoscopy examinations based on 70° rigid optics were performed in 13 euphonic and asymptomatic volunteers at an otorhinolaryngology specialist clinic; only one patient was excluded from the study. Images were taken with, and without, disposable intraoraldental cameraprotection cap; high-grade disinfection protocol was applied between examinations. Recorded videos were randomly distributed in a single-blind manner in order tobe evaluated by four otorhinolaryngologists, who answered a questionnaire comprising three questions. Statistical analysis was used to compare groups – which were defined by the use, or not, of protection cap - based on Wilcoxon non-parametric test. Statistical significance was set at 5% with 95% confidence interval. There was no statistically significant difference in image quality between examinations performed with, and without, protection cap (p = 0.646) or in the diagnosis confidence level of examinations performed with, or without, the barrier method. The use of disposable protection cap on intraoral dental camera did not significantly change the quality of imagestaken throughvideolaryngoscopy performed with 70° rigid optics in vocally healthy patients. Larynx visualization through different methods is an essential practice in the Otorhinolaryngology (ENTear, nose, throat) field; it is described as the crucial step to enable the diagnosis of pathologies in this segment (1) . Since the 19 th century, when Garcia's mirror for indirect larynxinspection was first used, methods have significantlyadvanced, mainly after 1970, due to the introduction of the optical fiber technology (2) (3) (4) . The 70º and 90º rigid fiberoptic laryngoscopes (RL) stand out among several methods available nowadays. According to Shao et al.(2002) , the 70º RL is the most used method for laryngeal examination (3) . Assumingly, flexible laryngoscopes are better tolerated by patients with intense nauseated reflexes, as well as withcervical movement and mandibular openinglimitation, and they are even preferred by some authors (3) (4) (5) . The technological advancement enabled developing rigid laryngoscopes equipped with camera and chip attached to its tip, a fact that made it possible digitizing imagestaken during the examinations. Therefore, these devices stand out for generating high-quality images during the examinations (6) . Plaatet al.(2014) have demonstrated that images generated by such devices are significantly better than the ones generated by conventional fiber optic laryngoscopes, and this finding is in compliance with the literature (1, 4) . Endoscopes used in these imaging methods are often contaminated with a range of microorganisms as they pass through the mucosa of the upper airways. Thus,it is mandatory performing efficient decontamination procedures to avoid the risk of cross-contamination between patients subjected to this examination, and between patients and examiners, vice versa (4, 5, 7 -11) . The severe acute respiratory syndrome caused by the new coronavirus (SARS-CoV-2) emerged in Wuhan (China), in December 2019; it presented high dissemination potential and rapid increase in the number of confirmed cases in other countries (12, 13, 14) .Clinical features of the disease caused by SARS-CoV-2 (COVID-19)such as cough, body temperature (fever) higher than 38ºC, headache, sore throat, nasal obstruction, olfactory loss, asthenia, rhinorrhea, myalgia and taste disorders -have been progressively elucidated in multicenter studies conducted worldwide (12) (13) (14) (15) (16) . However, effective antiviral drugscapable of treating the new coronavirus (SARS-CoV-2) are not yet available. Accordingly, multicenter studies have shown that Otorhinolaryngologists, Ophthalmologists, Anesthesiologists and Intensive Care Physicians are the medical professionals mostly infected by COVID-19 in Asia, Europe and in the United States (17) (18) (19) (20) (21) . These professionals are often in close contact with patients' oral and nasal cavities; thus, they are susceptible to the high potential of viral dissemination through secretions found in these cavities (17, 18) . Still, procedures associated with these specialties -such as orotracheal intubation -, as well as procedures involving patients' respiratory and gastrointestinal tracts, such as endoscopy, bronchoscopy and laryngoscopy, present high aerosolizationrisk (17) . Thus, it is valid reinforcing the use of barrier methods in otorhinolaryngological equipment. According to Spaulding's classification -used in the CDC's 2008 disinfection and sterilization guide for health facilities -objects that have contact with mucous membranes and oral fluids are categorized as semi-critical; thus, they require proper cleaning and, at least, high level disinfection after each use (9) . It is worth emphasizing that this statement is consistent with guidelines released by the main Brazilian national body (ANVISA -2006 (ANVISA - , 2009 and 2012) associated with this subject (22) (23) (24) . According to a Brazilian decree from 2012, the processing of health products must follow a Standard Operational Protocol (SOP) based on updated scientific references and on pertinent regulations (22) . In this very same year, the Brazilian Association of Otorhinolaryngology and Cervical-Facial Surgery (ABORL-CCF -AssociaçãoBrasileira de Otorrinolaringologia e CirurgiaCérvico-Facial) developed anSOP to process materials used in nasoendoscopy, videolaryngoscopy (VL) and videonaso-pharyngo-laryngoscopy examinations in medical practices (25) . This SOP enabled eliminating 99.9415% of organic material by cleaning and disinfecting the used devices with 70% alcohol, for approximately 15 minutes. However, some manufacturers have their own protocols, which add a step to the protocol: liquid asepsis based on theimmersion of the optics (only) in 0.2% peracetic acid solution for 2 minutes (8, 9, 11) , among others. The intraoral dental camera protection capis a disposable device used by dentists to perform exams in the oral cavity; however, it was first used as protection cap for videolaryngoscopesby Fonseca et al.(2017) (26) . This device is made available by several brands in the market; it has clearance by health surveillance agencies, since its effectiveness as barrier method has been confirmed. In addition, it is easily found in low-cost dental material houses, where unit prices range from R$ 0.25 to R$ 1.00, depending on the brand and on place of purchase. The aim of the current study was to evaluate the quality of images generated through, and the confidence level of,diagnosis based on videolaryngoscopyexaminations performed with intraoral dental camera equipped with disposable protection cap and connected to 70º rigid laryngoscope in vocally healthy individuals, we all as the feasibility of using it in the current pandemic context of COVID-19. Data collection was carried out after the study was approved by the ethics committee on human research, under opinion n. 1.761.602. Twenty-six (26) examinations were performed (13 with, and 13 without, the dental protection cap -DPC) in 13 euphonic and asymptomatic volunteers. Each volunteer underwent the examination with, and without, the intraoral protection cap. Mean, median, minimum and maximum values, 1 st and 3 rd quartiles, and standard deviation were used to describe the analyzed data. These parameters were also used to compare exams performed with, and without, intraoral protection cap. Wilcoxon's non-parametric test was used to evaluate questionnaire responses.Spearman's correlation coefficients were estimated to assess the association between quality of image and confidence level of diagnosis; p < 0.05 has indicated statistical significance. Data were analyzed in the IBM SPSS Statistics v.20.0 software (Armonk, NY: IBM Corp.). Twenty-six (26) We tested the null hypothesis of equal image quality-assessment scores for The percentage of normal results recorded for each exam was calculated as the ratio between the number of results classified as normal by all four examiners divided by the number of examiners (4) . There was not statistically significant difference between the percentage of results classified as normal by examiners in exams conducted with protection cap and the percentage of results classified as normal in exams conducted without it (p = 0.424). We tested the null hypothesis that scores recorded for the confidence level of the diagnosis were equal in assessments with, and without, protection cap versus the alternative hypothesis of different scores. Table 3 shows the descriptive statistics applied to each group (with, and without, protection cap), as well as to score differences (without cap minus with cap). This table also shows the dep value of the statistical test, which reached 0.638, i.e., there was not statistically significant difference inthe confidence level between exams conducted with, and without, dental protection cap. Spearman's correlation coefficient was estimated in each cap-defined group (without and with) in order to assess the association between image quality and confidence level of the diagnosis. Thus, we tested the null hypothesis of Spearman's correlation coefficient equal to zero (no association) versus the alternative hypothesis of non-zero Spearman's correlation coefficient (existence of association). Table 4 below presents the results recorded in the study (estimated correlations and depvalues of statistical tests). They indicate positive association between image quality and confidence level of the diagnosis for exams conducted with, and without, dental protection cap -i.e., the higher the quality of the image, the higher the confidence level of the diagnosis, based on examiners' assessment. We observed the progressive need of intensifying the use of barrier methods in ENT procedures throughout 2020, due to the pandemic caused by the new coronavirus (SARS-CoV-2). The need of performingexams with potential to produce aerosols under these conditions certainly requires changes in usual practices to avoid spreading the disease among patients and health professionals (27, 28) . The use of barrier devices, such as disposable caps, is addressed as optional by the previously mentioned CDC (2008) guidelines, as well as by the 2003 guideline for infection control in dental health by the same agency (9, 11) . There are reports about the use of disposable caps as barrier method in otorhinolaryngological exams since 1993 (29) , as well as in other endoscopic exams such as sigmoidoscopy (30) . Several studies have shownthe value of disposable capsfor the quality of image, as well astheir applicability and effectiveness as barrier mechanism (1, 4, 7, 8, 10, 29, (31) (32) (33) . One of them (conducted in 2014) showed that the use of the Slide-On ® EndoSheath ® System cap (Medtronic Xomed Inc, USA) decreased the quality of the image generated during videolaryngoscopy conducted with endoscope equipped with distal chip camera, although it did not affect the confidence level of the diagnosis (1) . Nevertheless, Silberman (2001) has evaluated the use of a disposable cap similar to the Slide-On ® EndoSheath ® one and found that, besides maintaining the quality parameters of the video naso-pharyngo-laryngoscopy exam, the cap enabled gaining time between examinations due to its easy and quick use and to lack of need to adopt traditional cleaning and disinfectionmethods. The aforementioned author addressed the use of the protection cap as a viable option for otorhinolaryngologists (10) . The use of disposable caps in endoscopic exams conducted in the Otorhinolaryngology field remains a controversial topic in the literature, but the possibility of using them is a subject of great value in the current health scenario imposed by COVID-19. Some studies have stated that using the cap is safe because it helps preventing cross-contamination by microorganisms (32, 33) , whereas others advocated that it is not recommended giving up on performing high-level endoscope disinfection between patients, despite the use of such a device (7, 8) . Conflicting results about changes in the quality of image were also observed in different studies that have used disposable barrier devices in endoscopic exams conducted in the Otorhinolaryngology field (1, 4, 10, 29, 30) . We opted for usingthe intraoral dental cap as barrier method in the current study due to its greater availability in the national market, as well asto its low cost in comparison to caps currently available in the national and international markets. In addition, the use of the cap requires shorter time than the disinfection process suggested in the SOP by ABORL, which is not universally accepted by the national epidemiological and sanitary surveillance departments or even by ANVISA. Another aspect to be taken into consideration is that the disinfection with peracetic acid solution suggested by ANVISA can damage the optics used in the examinations (10) . Based on results in the current study, there was not statistically significant difference in the quality of images between examinations conducted with, and without, the tested protection cap (Question 1). This finding was not in compliance with some findings available in the literature, since two studies conducted by Plaatet al. (1, 4) observed that the use of disposable cap in laryngoscopy examinations. Unlike the current study, which used a rigid endoscope, Plaatet al. used an endoscope with distal chip camera, which reduced the quality of the generated image (p <0.05). However, according to the aforementioned authors, there was not statistically significant difference in the confidence to diagnose the exam or in the diagnostic accuracy.In addition, Vazet al. (18) were also adamant in stating that using such a device changes the quality of the image. On the other hand, Silberman has stated that the use of disposable cap in flexible nasofibrolaryngoscopy (NFL) examinations did not influence the quality of the generated image (10) . Assumingly, the use of intraoral dental protection cap has led to betterimage quality results in the current study than the ones recorded in other studies; it happened because the dental protection cap is easier to use, more transparent and presents design better adapted to optics than devices used in other studies available in the literature. This hypothesis requires performing direct comparative study between caps in order to be ultimatelyconfirmed; however, this comparison transcends the scope of the present study. According to the present study, the better the quality of image, the greater the confidence in diagnosing the exam. Based on analysis of the possibility of making a diagnosis and of the confidence in the image generated for that purpose (Questions 2 and 3, respectively), there was also not statistically significant difference between exams conducted with, and without,the disposable cap (p > 0.05). These data were consistent with results found in the literature (1, 4) ;thus, it is possible stating that the use of disposable cap in the current study did not change the quality of the image of the exam to the point of generating statistically significant difference between diagnostic outcomes with, and without, such a device. With respect to disagreements in the current study about the quality of image in exams conducted with intraoral camera protective cap and protective caps used in laryngoscopy examinations, studiescomprising larger samples may show whether the quality of the image of the intraoral protection cap is better than that of the laryngoscopy protection cap in traditional rigid endoscopes. Cai and collaborators (2020) (27) have report changes in ENT procedures' routine in the United States due to the SARS-CoV-2 pandemic scenario, such as avoiding nasal sprays before nasal endoscopy procedures, prioritizing the use of small topical anesthetic compress, generating lesser sneeze reflex and subsequent droplet aerosolization. In addition, laryngoscopy exams must be performed by experts in order to better handle patients' airways (27) . However, the literature lacksstudies about the options of equipment to be used. Otorhinolaryngology and Cervical-Facial Surgery societies tend to consider laryngoscopy as strictly necessary only in critical cases, since its performance has direct impact on patients' management (28, 34) ; however, it is mandatory performing the efficient screening of possible infected individuals, using PPE and maintaining distance from patients in all steps before the procedure (28, 34) . On the other hand, the literature lacks proposals to optimize the use of this equipment, by maintaining reprocessing with isopropyl alcohol and glutaraldehyde (28, 34) , which have strong potential to damage the integrity of telescopes currently usedfor laryngoscopy purposes. This conflicting scenario reinforces the importance of conducting research about the use of protection caps and barrier methods, such as the herein conducted one. Additional studies on the use of protection caps in laryngoscopes can help better understanding the effectiveness of this method. Although disposable caps are not recently developed devices (16) , theyrequiresolid proof about their benefit and safety of use; however, it is plausible saying that they are promising devices for the advancement in endoscopic imaging screening in the Otorhinolaryngology field. The current team of researchers has other studies in progress inorder to prove the effectiveness of intraoral camera protection caps as barrier method against the contamination ofvideolaryngoscopy equipment by microorganisms, as well as to evaluate the quality of videolaryngoscopy images generated in other devices, such as laryngoscopes equipped with distal chip camera, by using protection caps. The use of dental intraoral camera cap did not significantly change the quality of image and the confidence in the diagnosis ofvideolaryngoscopyexaminations conducted with 70º rigid optics in vocally healthy individuals. The effect of endoscopic sheaths on visualization in distal chip and fiberoptic laryngoscopy On standardizing the laryngeal examination Clinical Evaluation of 70° and 90° Arch Otolaryngol --Head Neck Surg Distal chip versus fiberoptic laryngoscopy using endoscopic sheaths: Diagnostic accuracy and image quality A review of reprocessing techniques of flexible nasopharyngoscopes Otolaryngol -Head Neck Surg Digital image processing of laryngeal lesions by electronic videoendoscopy Evaluation of Endoscope Sheaths As Viral Barriers Prevention of disease transmission during flexible laryngoscopy Guideline for Disinfection and Sterilization in Healthcare Facilities. Departament of Health and Human Services -CDC Non-inflatable sterile sheath for introduction of the flexible nasopharyngolaryngoscope Guidelines for Infection Control in Dental Health-Care Settings -2003. Prepared by Guidel Infect Control Dent Heal Settings Clinical findings of patients with coronavirus disease 2019 in Jiangsu province, China: A retrospective, multi-center study European Patients with mild-to-moderate Coronavirus Disease The Prevalence of Olfactory and Gustatory Dysfunction in COVID-19 Patients: A Systematic Review and Meta-analysis. Otolaryngology-Head and Neck Surgery Characteristics and Clinical Outcomes of Adult Patients Hospitalized with COVID-19 -Georgia Clinical and radiological changes of hospitalised patients with COVID-19 pneumonia from disease onset to acute exacerbation: a multicentre paired cohort study Letter: Precautions for Endoscopic Transnasal Skull Base Surgery During the COVID-19 Pandemic Clinical Characteristics of 138 Hospitalized Patients With 2019 Novel Coronavirus-Infected Pneumonia in Wuhan Characteristics of and Important Lessons From the Coronavirus Disease 2019 (COVID-19) Outbreak in China 7ª Nota de orientação aos médicos Otorrinolaringologistas em relação à doença causada pelo novo Coronavírus (COVID-19) -Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial, 30 de março de 2020 COVID-19: Limiting the Risks for Eye Care Professionals Resolução da Diretoria Colegiada -RDC N o 15 Available at: bvsms.saude Resolução n° 2.606, de 11 de Agosto de Informe Técnico n°02 Protocolo Operacional Padrão (POP) para Analysis of videolaringoscopy images with and without protective cover for the intraoral odontological camera Otolaryngology Resident Practices and Perceptions in the Initial Phase of the U.S. COVID -19 Pandemic. The Laryngoscope Flexible Laryngoscopy and COVID-19. Otolaryngology-Head and Neck Surgery New technique for the sterile introduction of flexible nasopharyngolaryngoscopes Use of a disposable sheath system for flexible sigmoidoscopy in decentralized colorectal cancer screening Optical quality of the nasendoscope with and without the endosheath Flexiblenasendoscope with a disposable-sheath system versus standard nasendoscopy: a prospective, randomized trial A comparison of two methods for preventing cross-contamination when using flexible fiberoptic endoscopes in an otolaryngology clinic: Disposable sterile sheaths versus immersion in germicidal liquid Nasal, pharyngeal and laryngeal endoscopy procedures during COVID-19 pandemic: available recommendations from national and international societies