key: cord-0967580-w32xtrd8 authors: Wang, Kun; Liu, Yilin; Liu, Caiyun; Zhu, Hanchuang; Li, Xiwei; Yu, Miaohui; Liu, Lunying; Sang, Guoqing; Sheng, Wenlong; Zhu, Baocun title: A new-type HOCl-activatable fluorescent probe and its applications in water environment and biosystems date: 2022-05-21 journal: Sci Total Environ DOI: 10.1016/j.scitotenv.2022.156164 sha: 2eddad624890a5bc9303b3658c893a83a7e7cd0f doc_id: 967580 cord_uid: w32xtrd8 The outbreak and spread of Corona Virus Disease 2019 (COVID-19) has led to a significant increase in the consumption of sodium hypochlorite (NaOCl) disinfectants. NaOCl hydrolyzes to produce hypochlorous acid (HOCl) to kill viruses, which is a relatively efficient chlorine-based disinfectant commonly used in public disinfection. While people enjoy the convenience of NaOCl disinfection, excessive and indiscriminate use of it will affect the water environment and threaten human health. Importantly, HOCl is an indispensable reactive oxygen species (ROS) in human body. Whether its concentration is normal or not is closely related to human health. Excessive production of HOCl in the body contributes to some inflammatory diseases and even cancer. Also, we noticed that the concentration of ROS in cancer cells is about 10 times higher than that in normal cells. Herein, we developed a HOCl-activatable biotinylated dual-function fluorescent probe BTH. For this probe, we introduced biotin on the naphthalimide fluorophore, which increased the water solubility and enabled the probe to aggregate in cancer cells by targeting specific receptor overexpressed on the surface of cancer cell membrane. After reacting to HOCl, the p-aminophenylether moiety of this probe was oxidatively removed and the fluorescence of the probe was recovered. As expected, in the PBS solution with pH of 7.4, BTH could give full play to the performance of detecting HOCl, and it has made achievements in detecting the concentration of HOCl in actual water samples. Besides that, BTH had effectively distinguished between cancer cells and normal cells through a dual-function discrimination strategy, which used biotin to enrich the probe in cancer cells and reacted with overexpressed HOCl in cancer cells. Importantly, this dual-function discrimination strategy could obtain the precision detection of cancer cells, thereby offering assistance for improving the accuracy of early cancer diagnosis. Since the outbreak of Corona Virus Disease 2019 began, there have been serious consequences (Chen et al., 2021; WHO, 2021) . Countries attach great importance to disinfection and sterilization in public places because of the seriousness of the epidemic (Lewis et al., 2021; Service, 2020) . Sodium hypochlorite (NaOCl) solution is a chlorine-based disinfectant whose active ingredient is sodium hypochlorite, which can be hydrolyzed into hypochlorous acid (HOCl) and then produce disinfection and sterilization effect. NaOCl is also listed by the U.S. Environmental Protection Agency as one of the most used disinfection active ingredients to contain COVID-19 (EPA, 2021) . On the bright side, the use of NaOCl disinfectant has contributed to limiting the spread of the outbreak. However, incorrect and indiscriminate use of disinfectants containing NaOCl will increase the potential risk of ecological and environmental damage (Chen et al., 2021; Nabi et al., 2020; Thakur et al., 2021) . Recent reports indicate that the residues of NaOCl disinfectant entering water will pollute it, posing a threat to aquatic life, causing ecological damage, and then affecting human health (Chu et al., 2020; Rafiee et al., 2022; Zhang et al., 2020) . Therefore, it is a significant topic to detect whether there is excessive HOCl in water environment. On the other hand, HOCl is a vital small molecule in organisms, belonging to one of the reactive oxygen species (ROS), produced by the action of myeloperoxidase (MPO) on chloride ions (Cl -) and hydrogen peroxide (H 2 O 2 ), and plays a pivotal role in cell signaling and immune defense system (He et al., 2020; J o u r n a l P r e -p r o o f Journal Pre-proof Rayner et al., 2018; Bauer, 2018) . As a "double-edged sword", HOCl has an evil side. It has been reported that some inflammatory diseases and even cancer are related to excessive HOCl concentration (Duan et al., 2019; Hou et al., 2022; Zhu et al., 2018; Pan et al., 2012) . Significantly, the concentration of ROS in cancer cells is about 10 times higher than that in normal cells (Antunes et al., 2001; Ye et al., 2017) , which may assist in distinguishing between cancer cells and normal cells. Thus, tracing HOCl in biosystems is also of extraordinary significance. Compared with traditional methods, small molecule fluorescent probes have attracted additional attention in virtue of their advantages including non-invasiveness, simple operation and real-time imaging Shu et al., 2020; Wu et al., 2021; Wu et al., 2021; Rong et al., 2021; Zhu et al., 2016) . The currently reported HOCl fluorescent probes have relatively simple functions, and have some disadvantages such as low sensitivity, long response time and poor water solubility. (Gao et al., 2021; Hou et al., 2020; Li et al., 2017; Zhu et al., 2021; Zhu et al., 2014) . With regards to this, we designed and synthesized a HOCl-activatable biotinylated fluorescent probe BTH to improve the above shortcomings (Scheme 1). As a result of the introduction of the biotin functional group, the water solubility of BTH is increased, which provides a favorable condition for the detection of HOCl in aqueous solution. More importantly, biotin is a pivotal cofactor of carboxylase activity, and it is more favored by rapidly proliferating cells especially cancer cells (Jang et al., 2017; Said, 1999; Yang et al., 2009) . It is reported that the sodiumdependent multivitamin transporter (SMVT) is overexpressed on the membrane J o u r n a l P r e -p r o o f Journal Pre-proof surface of cancer cells to ensure the uptake of biotin by cells (Błauż et al., 2021; Maiti et al., 2013; Vadlapudi et al., 2012) . Hence, BTH containing biotin is more likely to be enriched in cancer cells, which is instrumental in avoiding the "false positive" results when distinguishing between normal cells and cancer cells (She et al., 2021; Wang and Chen, 2021) . On the other side, we modified naphthimide fluorophore with paminophenylethe an excellent reaction group of HOCl. BTH was non-fluorescent, which was ascribed to the photo-induced electron transfer (PET) effect produced by 69, 164.20, 163.51, 163.16, 161.07, 147.32, 144.12, 133.25, 131.70, 129.48, 128.60, 127.16, 123.28, 122.66, 122.12, 115.71, 115.47, 109.67, 61.42, 59.65, 55.81, 36.83, 35.71, 28.54, 28.42, 25.60 BTH was constructed on the 4-hydroxy-1,8-naphthalimide fluorophore reported firstly by our group (Zhu et al., 2011) . This fluorophore had a conspicuous intramolecular charge transfer (ICT) structure, which had aroused widespread concern J o u r n a l P r e -p r o o f Journal Pre-proof (Park et al., 2020; Wen et al., 2017; Zhou et al., 2019) . Furthermore, the paminophenylether receptor had been reported to be a good HOCl detection group and it could produce the PET effect to hinder the luminescence of BTH (Jia et al., 2019). After BTH reacted with HOCl, the fluorescence was turned on. Thus, we bonded 4aminophenol to the fluorophore by a nucleophilic substitution reaction to form ether bond like compound 3. The carboxylic acid moiety on biotin was connected to the naphthalimide framework through an amide bond, which could increase the water solubility of BTH and its ability to aggregate in cancer cells (Jung et al., 2014) . Then, we characterized the structure of BTH by 1 H-NMR and 13 C-NMR, and the product of the reaction of BTH and HOCl was confirmed by HRMS. The proposed reaction mechanism was that the p-aminophenylether part of the probe was removed by HOCl oxidation (Scheme 2). After verifying the correct structure of BTH by means of characterization, a series of sensing properties of BTH for responding HOCl were discussed, using the aqueous solution as test solution with the addition of phosphate buffered saline (PBS) solution (pH = 7.4). To start with, the time kinetics experiment of BTH response to HOCl was studied. As could be seen from Figure 1 , adding HOCl (5 μM) to the probe (5 μM) solution (10 mM PBS, pH = 7.4), the reaction could be completed within a few seconds. The fluorescence intensity at 553 nm reached the maximum and remained unchanged. This ability of BTH to react rapidly to HOCl, benefiting from p-J o u r n a l P r e -p r o o f Journal Pre-proof aminophenylether group, suggested that BTH could detect HOCl quickly in aqueous solution and had the potential to capture HOCl in biological systems. Furthermore, we performed a fluorescence titration experiment with HOCl from 0 to 30 μM in the PBS solution of BTH (5 μM). As shown in Figure 2A , BTH was barely provided with luminescent properties, which was ascribed to the PET effect produced by the p-aminophenylether receptor. After adding HOCl with a concentration of 0 to 30 μM to the PBS solution of BTH, a significant emission peak at 553 nm was observed and the fluorescence intensity increased gradually. In the meanwhile, when HOCl was in the low concentration range from 0 to 1 μM, there existed a good linear correlation that the Y-axis represented the fluorescence intensity at 553 nm, and the X-axis represented the concentration of HOCl ( Figure 2B ). The linear regression equation was got as y = 102923 × [HOCl] (μM) + 35601 and the square of the correlation coefficient was 0.9965. The limit of detection was calculated as low as 17 nM. This result indicated that BTH can be used to detect HOCl in aqueous solution and will be a potential tool for detecting HOCl in actual water samples. It was sufficiently sensitive to HOCl under simulated physiological conditions and was conducive to tracing it in biosystems. Subsequently, we evaluated the responsiveness of BTH to various analytes J o u r n a l P r e -p r o o f Journal Pre-proof including ions, biological mercaptans and other reactive oxygen species (Figure 3 ). The fluorescence of BTH at 553 nm did not change significantly when other higher concentrations of analytes were added. On the contrary, low concentrations of HOCl could cause strong fluorescence enhancement. In other words, BTH showed satisfactory selectivity to HOCl. Overall, it was implied that BTH was feasible in the discrimination of HOCl in aqueous solution.
Since high concentrations of HOCl in water can cause water pollution and the death of aquatic organisms, it is of great significance to detect hypochlorous acid in the water environment. Considering the above reasons, as well as the results of the spectral test, we were motivated to apply BTH to the detection of HOCl in practical water samples (Table 1) . Three water samples were collected in this work. First, the large impurities in the water sample were filtered out, and then the treated water sample was analyzed with BTH. The results show that no HOCl at a higher concentration than 17 nM could be detected in the three water samples. Next, 0.5 μM and 1 μM HOCl were added to the treated water samples and recovered. The three water samples in the experiment have good recoveries with 93.13%-107.83%. It indicated that BTH could be applied to detecting HOCl in actual water samples. The cytotoxicity of BTH was first evaluated before the ability to apply it in living cells. As shown in Figure S1 , the results of cell counting kit (CCK-8) analysis showed that BTH had low toxicity to HeLa cells. After that, we studied the ability of Considering the design idea of BTH, in order to verify the ability of it to distinguish between normal cells and cancer cells, we selected two types of normal cells (RAW264.7 and HUVEC cells) and four types of cancer cells (MGC-803, HeLa, HepG2 and SH-SY5Y cells) for the experiment. The above six kinds of cells were incubated with BTH for 25 min. As expected, the RAW264.7 and HUVEC cells showed weak fluorescence (Figure 5a ). In contrast, the green fluorescence of the MGC-803, HeLa, HepG2 and SH-SY5Y cells was especially strong (Figure 5b ). The histogram also showed a big difference in the fluorescence intensity between normal cells and cancer cells (Figure 5c ). It could be said that BTH had potential application in differentiating between normal cells and cancer cells. Subsequently, another experiment demonstrated that the biotin portion of BTH could enable BTH to be enriched in cancer cells. We selected HeLa cells for biotin inhibition experiment. Cells incubated with biotin followed by BTH (Figure 6c) showed weaker fluorescence intensity than cells incubated with BTH only (Figure 6b ). The histogram was more intuitive (Figure 6d ). This result could be ascribed to the early incubation of biotin occupying the receptor channel on the cell surface and thus blocking the uptake of BTH (Chai et al., 2021) . On the other hand, we performed the same discrimination experiment using probe BAH, a probe not modified with biotin (Jia et al., 2019). BAH, without the J o u r n a l P r e -p r o o f Journal Pre-proof assistance of biotin, did not tend to accumulate in cancer cells. The fluorescence of the six kinds of cells was closely after incubation with BAH ( Figure S9 ), so the control probe was going to confuse cancer cells with normal cells. These above results might provide forceful evidence that BTH could be a useful tool for tumor imaging. In this work, we designed and synthesized a biotin-functionalized fluorescent probe BTH. When there existed HOCl, BTH with good water solubility and high sensitivity could selectively turn on fluorescence as well as had the ability of rapid respond, which could be used for the detection of HOCl in aqueous solution. He, X., Chen, H., Xu, C., Fan, J., Xu, W., Li, Y., Deng, H., Shen, J., 2020 . COVID-19 rarely spreads through surfaces. So why are we still deep cleaning? A tumor-specific and mitochondriatargeted fluorescent probe for real-time sensing of hypochlorite in living cells Gemcitabine-coumarin-biotin conjugates: a target specific theranostic anticancer prodrug Massive use of disinfectants against COVID-19 poses potential risks to urban wildlife Hypochlorite-induced oxidative stress elevates the capability of HDL in promoting breast cancer metastasis Ratiometric fluorescent probe for monitoring tyrosinase activity in melanosomes of melanoma cancer cells Health consequences of disinfection against SARS-CoV-2: Exploring oxidative stress damage using a biomonitoring approach An integrated fluorescent probe for ratiometric detection of glutathione in the golgi apparatus and activated organelle-targeted therapy Does disinfecting surfaces really prevent the spread of coronavirus? Science An endoplasmic reticulum-targeted ratiometric fluorescent probe for the sensing of hydrogen sulfide in living cells and zebrafish Cellular Uptake of Biotin: Mechanisms and Regulation A near-infrared fluorescent probe for accurately diagnosing cancer by sequential treatment to effectively control the pandemic Sodium dependent multivitamin transporter (SMVT): a potential target for drug delivery Detection of atherosclerosis-associated HOCl using a mitochondria-targeted fluorescent probe Discrimination between cancerous and normal cells/tissues enabled by a near-infrared fluorescent HClO probe Revealing HOCl burst from endoplasmic reticulum in cisplatin-treated cells via a ratiometric fluorescent probe Smart fluorescent probe strategy for precision targeting hypoxic tumor Pinpoint Diagnostic Kit for Heat Stroke by Monitoring Lysosomal pH A highly specific fluorescent probe for hypochlorous acid and its application in imaging microbeinduced HOCl production A tumorspecific cascade amplification drug release nanoparticle for overcoming multidrug resistance in cancers Targeting cancer cells with biotin-dendrimer conjugates Disinfection threatens aquatic ecosystems A highly specific and ultrasensitive near-infrared fluorescent probe for imaging basal hypochlorite in the mitochondria of living cells Highly specific and ultrasensitive two-photon fluorescence imaging of native HOCl in lysosomes and tissues based on thiocarbamate derivatives Recent advances in 4-hydroxy-1,8-naphthalimidebased small-molecule fluorescent probes An "Enhanced PET"-based fluorescent probe with ultrasensitivity for imaging basal and elesclomol-induced HClO in cancer cells A 4-hydroxynaphthalimide-derived ratiometric fluorescent chemodosimeter for imaging palladium in living cells In situ visualization of peroxisomal peroxynitrite in the livers of mice with acute liver injury induced by carbon tetrachloride using a new twophoton fluorescent probe Guoqing Sang a , Wenlong Sheng b * and Baocun Zhu a * a School of Water Conservancy and Environment *Corresponding author. E-mail address: liucaiyun1982072@163.com (C. Liu), lcyzbc@163.com (B. Zhu), and 15618694162@163.com (W. Sheng) We gratefully acknowledge financial support from the NSFC (22176070 and