key: cord-0967030-fvzmdvs6 authors: Maher, Blake; Chavez, Reynaldo; Tomaz, Gabriel C.Q.; Nguyen, Thien; Hassan, Yassin title: A fluid mechanics explanation of the effectiveness of common materials for respiratory masks date: 2020-08-28 journal: Int J Infect Dis DOI: 10.1016/j.ijid.2020.07.066 sha: 209971b6195d22bd77bf01131980b51fcef04024 doc_id: 967030 cord_uid: fvzmdvs6 Objectives Face masks are an important component of personal protection equipment employed in preventing the spread of diseases such as COVID-19. As supply of mass-produced masks has decreased, the use of homemade masks has become more prevalent. It is important to quantify the effectiveness of different types of materials to provide useful information, which should be considered for homemade masks. Methods Filtration effects of different types of common materials were studied by measuring the aerosol droplet concentrations in the upstream and downstream regions. Flow-field characteristics of surrounding regions of tested materials were investigated using a laser-diagnostics technique, i.e., particle image velocimetry. Pressure difference across the tested materials were measured. Results Measured aerosol concentrations indicated a breakup of large-size particles into smaller particles. Tested materials had higher filtration efficiency for large particles. Single-layer materials were less efficient, but they had a low pressure drop. Multi-layer materials could produce greater filtering efficiency with an increased pressure drop, which is an indicator of comfort level and breathability. The obtained flow-fields indicated a flow disruption downstream of the tested materials as the velocity magnitude noticeably decreased. Conclusions The obtained results provide an insight to flow-field characteristics and filtration efficiency of different types of household materials commonly used for homemade masks. This study allows comparison to mass-produced masks under consistent test conditions while employing several well-established techniques. The use of face masks has been widely accepted as the first personal protection during the COVID-19 pandemic because the transmission of respiratory virus is mainly via human laden fluid particles, i.e., aerosols and droplets (Konda et al., 2020; Mittal et al., 2020; Kutter et al., 2018; Stelzer-Braid et al., 2009; Milton et al., 2013) . In addition to maintaining a social distance and constantly wash hands with soap, wearing personal face masks can provide an immediate solution to individuals who may live and/or work in the areas, such as public offices, supermarkets, hospitals, buildings, and train stations, with a high risk of exposing to the respiratory virus. Many studies have attempted to characterize respiratory aerosol droplet characteristics such as density, velocity and size distributions (Wells, 1934; Duguid, 1946; Wells, 1955; Morawska et al., 2009; Xie et al., 2009; Han et al., 2013; Bourouiba et al., 2014; Scharfman et al., 2016; Asadi et al., 2019) . Measured droplet sizes can vary few orders of magnitude, i.e., O(0.1) to O(1,000) µm (Mittal et al., 2020) . While large size droplets may settle before evaporating and deposit on surrounding surfaces, small and medium-sized droplets evaporate and form droplet nuclei that may stay airborne or be suspended for many hours. The filtration of aerosol droplets using a face mask is governed by the basic mechanisms: impaction, gravity sedimentation, interception, diffusion, and electrostatic attraction (Hinds, 1999; Vincent, 2007; Konda et al., 2020; Mittal et al., 2020) . The contribution of each mechanism to the filtration effects of face mask depend on the materials used, aerosol droplet sizes, and the relative conditions (temperature, humidity, and air velocity) of considered areas. For aerosol droplets ranging from ∼ 1 µm to 10 µm, sedimentation, impaction, and interception mechanisms are more important (Rostami, 2009 ). For small particles as droplet-nuclei-sized particles, i.e., less than 1 µm, diffusion by Brownian motion and interception of particles by the filter fibers are the dominant mechanism (Konda et al., 2020) . The electrostatic attraction is important to catch the nanometer-sized particles, which can penetrate through the holes in the material structures. The droplet nuclei may have a significant travel distance depending on the ambient air currents and indoor environments and cabins of transportation vehicles (Bourouiba et al., 2014) . In these spaces, the presence of circulation flows by ventilation systems, the open/close mechanisms of doors and their effects to the airborne transmission of respiratory virus are important and should be carefully considered (Tang et al., 2006; Li et al., 2007; Craven and Settles, 2006; MacIntyre et al., 2008; Licina et al., 2014; Offeddua et al., 2016) . Personal face mask can be considered as the physical barriers and using face masks in public areas could retard the transmission of respiratory infections (Barasheed et al., 2016; Mittal et al., 2020) . The increasing in demand and reducing in supplies of commercial masks have brought the option of do-it-yourself (DIY) or homemade masks to be a practical and feasible solution. Homemade masks usually consist of various household materials such as synthetic and natural cloths (cotton and non-woven fabric), microfiber cloths, and households filtering materials, for example HVAC filters, coffee filters, and vacuum bag (Chughtai et al., 2014; Konda et al., 2020) . It is essential to acquire a proper understanding on the effects of commonly used materials for DIY face masks such as the filtration efficiency and the effects of face masks to surround flow-fields. The focus of the present study is to investigate the aerosol filtration efficiency of common household materials and their effects to the flow characteristics in the vicinity flow regions. The flow field characteristics in the upstream and downstream regions of tested materials are obtained using a laser-diagnostics approach, i.e., particle image velocimetry (PIV) technique. This study utilized an isokinetic sampling probe to collect a small volume of aerosol droplets for analysis. It is noted that the velocity chosen in this study was within the range of air flow velocities that are commonly found in the indoor public areas, such as homes, offices, supermarkets, airplanes, trains, and buses, where the air flows are circulated by the ventilation systems. Characterizing the effectiveness of respiratory masks with respect to the airborne transmission by the air flows within these areas is important. The conditions tested in this study are different compared to a cough or a regular breathing such that the air velocity generated by a cough or regular breathing is not continuous and represented as a short-pulse (∼0.2 s) velocity. The maximum velocity of a cough/breathing could be within the range from 10 m/s to 16 m/s. Recent experimental, numerical and modelling studies can be found in Busco et al. J o u r n a l P r e -p r o o f (2020) for the dynamics of human sneezing and asymptomatic respiratory virus transmission, and in Dbouk and Drikakis (2020a, b) for the penetration and travel distances of airborne droplets through a face mask. [Figure 1 about here.] In this study, filtration efficiency of common household materials, such as cotton, nonwoven fabric (fabric 1), micro fiber cloth, HVAC filter, shower curtain, vacuum bag, coffee filter, made as a single-layer, two-layers, and three-layers, and commercial surgical mask and R95 mask listed in Table 1 are studied. Figure 1 shows an overview of the experimental facility constructed to study the effects of materials to the flow behavior in the vicinity regions. The facility had a cross-sectional area of 7.62×7.62 cm 2 and a total length of 182.88 cm. The facility was divided into three equal sections, each had a 60.96 cm length, that were connected using flanges. The tested materials were placed in between the second and the third sections. The air volumetric flow rate of 300 LPM measured by a rotameter was maintained for all the measurements. The resulted air velocity in the upstream region of the tested materials was 0.86 m/s, which is in the range of air velocity inside public areas, such as offices and buildings, generated by the ventilation system. Differential pressures (ΔP) across the tested materials, indicating the comfort level and breathability of a person when putting the face masks, were measured using a Dwyer manometer with a reading accuracy of 0.02 inch of water (∼ 4.97 Pascal). To generate the liquid aerosol droplets, a six jet-atomizer (TSI Model 9306) was used to aerosolize the Di-Ethyl-Hexyl-Sebacat (DEHS) fluid. The generated liquid droplets had a mean diameter of 1 µm and a density of 910 kg/m 3 . The aerosol droplet size and density are chosen to represent the common properties of airborne particles that are often considered more harmful than larger-size particles because of their ability to penetrate to human bronchi and lungs (Shakya et al., 2017) . To acquire the aerodynamic flow fields in the upstream and downstream regions of the tested materials, two-dimensional two-component (2D2C) PIV measurements were performed. The 2D2C PIV system consisted of a 20 W continuous laser with a green wavelength of 527 nm and a high-speed CMOS Phantom M310 camera. For each flow measurement of the tested materials, the camera operated in a single-frame mode and captured a sequence of 8,341 images of 1,280 × 1,280 pixels at a frequency of 500 Hz. The collection of PIV experimental images was processed using in-house codes (Eckstein and Vlachos, 2009; Nguyen et al., 2018a; Nguyen et al., 2018b; Nguyen et al., 2019a; Nguyen et al., 2019b; Nguyen et al., 2019c; Nguyen et al., 2020) . The J o u r n a l P r e -p r o o f estimated the overall uncertainty of the PIV processing code was approximately 0.1 pixels, yielding less than 1% of the mean centerline velocity of the upstream region. The particle concentrations at the upstream and downstream locations of the tested materials were measured utilizing an isokinetic sampling probe, which collected a small volume of aerosol droplets for flow analysis. The spatial distances from the tested materials to the upstream and downstream sampling locations of OPS were 520 mm and 470 mm, respectively. For each tested material, ten experimental runs to obtain particle concentrations were performed for each sampling location; each run was recorded with a duration of 1 minute. [ Figure 2 about here.] A high magnification imaging system was utilized to capture images of tested materials' surfaces. The imaging system consisted of an 8-MP CCD camera (Imperx B3320) with a maximum resolution of 2,458 × 3,312 pixels a 12X zoom lens with 3-mm fine focus (ThorLabs MVL12X3Z). The scaling factor between image pixel to physical dimension (µm) is 8:10. High-resolution images taken on the surfaces of tested materials are provided in Figure 2 . Figure 4 confirmed the significant reduction of velocity magnitude in the downstream region that was observed in Figure 3 of the mean velocity fields. In this section, results obtained from measurements of aerosol droplet concentrations and pressure differences across the tested materials are presented. The filtration efficiency per aerosol droplet size, , is defined as where is the aerosol diameter at bin ℎ , , and , are the concentrations measured at the upstream and downstream locations, respectively. If the computed filtration efficiency was below 0, i.e., when , < , , the negative values were removed from the result presentations and further calculations. The averaged filtration efficiency is computed using the filtration efficiency weighted by the mass of aerosol droplets of various bins. It is expressed as where is the mass of aerosol droplet computed for bin ℎ . [ Figure 5 about here.] Figure 5 shows the results of aerosol droplet concentrations measured at the upstream, , and downstream, , locations of the tested materials as a function of particle sizes. Results were obtained at the flow rate of 300 LPM and for different types of materials, including singlelayer, two-layers, and combined multilayers of various materials. Table 1 summarizes the averaged filtration efficiency and measured pressure differences between the upstream and downstream locations for various materials tested in this study. In Figure 5 , aerosol concentrations measured by the OPS at the upstream location of tested materials showed high values for aerosol sizes ranging from 1 µm to 4.7 µm. This range of aerosol droplet diameters matched well with the performance characteristics provided by the manufacture for the aerosol droplet generator used in this study. For all tested materials, within the size from 1 µm to 4.7 µm, the measured aerosol concentrations at the downstream location reduced, indicating the filtration effects of studied materials. For the concentration measurements of aerosol sizes smaller than 0.7 µm, Figure 5 showed that aerosol concentrations increased and mainly distributed within the aerosol sizes ranging from 0.38 µm to 0.52 µm. Such observations could be explained by the fact that when aerosol droplets with large diameters impinged onto the front size of tested materials, they broke into smaller droplets and passed through the layer. In this circumstance, characteristics of aerosol droplets, such as sizes and concentrations, measured at the downstream location will J o u r n a l P r e -p r o o f depend on the porosity of tested materials. Among the tested materials as a single layer, the cotton, fabric 1, and micro fiber cloth have nearly similar concentrations of aerosol droplets larger than 1 µm measured at the downstream location. From Figure 5 , it is found that the filtration effects of tested materials as combined layers increased when compared to the filtration effects of single layer materials. [ Figure 6 about here.] Figure 6 depicts filtration efficiency of various materials that were tested as a single layer, i.e., cotton, fabric 1, micro fiber, HVAC filter, and shower curtain, and as multiple layers, i.e., vacuum bag, surgical mask, mask R95, cotton-cotton, cotton-fabric 1, cotton-HVAC filter, cotton-coffee filter, cotton-coffee filter-cotton, and cotton-coffee filter-fabric 1. In Figure 6 , the computed filtration efficiency are presented per aerosol droplet size ranging from 1 µm to 4.67 µm. In comparisons of filtration efficiency computed for materials tested as a single layer, it can be seen that the shower curtain and HVAC filter had lower efficiency for all aerosol droplets sizes and their averaged filtration efficiency were 74.4% and 74.7%, respectively. Cotton, fabric 1, and micro fiber had their filtration efficiency greater than 92% for aerosol droplets with sizes from 2.42 µm and higher, and the averaged filtration efficiency were 87%, 83%, and 83%, respectively. In Figure 6 (bottom), it can be seen that the uses of multilayer materials combining cotton, fabric 1, HVAC filter, and coffee filter have improved the filtration efficiency for all the aerosol droplet sizes. Moreover, as can be observed in Table 1 that the averaged filtration efficiency of the combined multilayer materials increased from 4% to 15% when compared to those of the single layer materials. It is important to note that at the aerosol droplet size of 2.42 µm, all the tested multilayer materials had their filtration efficiency greater than 95%. Results presented in Figure 6 and Table 1 also included the filtration efficiency computed for the commercial surgical mask with 3 layers and R95 mask with 5 layers. It is observed that the surgical masks had lower filtration efficiency than the cotton-cotton at droplet sizes of 1 µm and 1.25 µm. However, for aerosol droplets with sizes greater than 2.42 µm, filtration efficiency of surgical mask increased significantly to greater than 95%. The tested R95 mask had very high filtration efficiency for all the aerosol droplet sizes, i.e., 93.4% at 1 µm and greater than 95% for droplet sizes larger than 1.25 µm. The averaged filtration efficiency of surgical mask and R95 mask was 81.4% and 99%, respectively. [ Table 1 about here.] The measured pressure differences across the tested materials provided in Table 1 could be used as an indicator for the level of comfort and breathability when the materials are used for face masks. For the single-layer materials, non-woven fabric 1 had the smallest pressure difference (29.9 Pa) due to its porous structure, while cotton had the highest pressure drop of 74.7 Pa. Pressure differences of the two-layer materials increased approximately 3 to 4 times J o u r n a l P r e -p r o o f higher than those of the single-layer ones. It is interesting to see that the tested vacuum bag (2 layers) also had a considerable averaged filtration efficiency of 95.2%. However, its pressure difference of 478 Pa is significant when compared to other two-layer materials, indicating the low-level of comfort and breathability if used as a face mask. The combinations of cotton-HVAC filter and cotton-fabric 1 had the smallest pressure difference of 211.7 Pa and 214.2 Pa, respectively, and similar averaged filtration efficiency. Results presented in Table 1 indicated that the use of cotton-coffee filter material had an averaged filtration efficiency of 91% but a high-pressure difference of 473 Pa, i.e., more than 2 times greater than that of cotton-fabric 1. The filtration effects of single-layer materials, i.e., cotton, fabric 1, and micro fiber, were also tested after they were washed using a washer for 20 minutes. The same process of concentration measurements at the upstream and downstream locations was performed to the washed materials. Results shown in Table 1 indicated that the averaged filtration efficiency of cotton, fabric 1 and micro fiber reduced around 2%-4% after being washed with a washer. Among the three-layer materials tested in this study, the cotton-coffee filter-cotton, and cotton-coffee filter-fabric 1 had their filtration efficiency higher than 90%. Although the surgical mask had an averaged filtration efficiency of 81.4%, its pressure difference of 378.6 Pa was the smallest one among all three-layer materials. The tested R95 mask (5 layers) had a pressure difference of 169.4 Pa, which was even lower than those of the two-layer materials. This could be explained by the fact that 5 layers of R95 mask were porous layers, yielding small pressure drop values. The focus of this study was to investigate the filtration effects of various materials that are commonly available in households and stores and have been considered for DIY or homemade respiratory masks. The filtration efficiency of single-layer and multi-layer materials were characterized for aerosol particles ranging from 0.3 µm to 6 µm, i.e., this range is within the aerosol-based virus transmission. In addition, the flow-field characteristics in the upstream and downstream regions of the tested materials were experimentally acquired to visualize the effects of materials to the flow. It was found that the flow-fields in the downstream region were altered by the presence of the tested materials, such that the velocity magnitude significantly reduced. The probability distributions of velocity magnitudes computed for the upstream region of the tested materials were almost similar to that of the base case, i.e., flow-fields experimentally obtained without the tested materials. On the other hand, probability distributions of velocity magnitudes computed for the downstream region were different to the base case, confirming the velocity reduction observed in the velocity flow fields. All tested materials provided filtration effects to aerosol droplets within the size from 1 to 4.7 µm. Besides, the obtained results indicated that large-size aerosol droplets impinged onto the tested materials, broke into smaller droplets and passed through the layer. As the singlelayer materials, cotton, fabric 1, and micro fiber cloth had similar filtration efficiency. Shower curtain and HVAC filter had lower efficiency for all aerosol droplets sizes and their averaged filtration efficiency were 74.4% and 74.7%, respectively. When the materials were made of multiple layers, combining cotton, fabric 1, HVAC filter, and coffee filter, the acquired results of filtration efficiency were found to improve for all the aerosol droplet sizes. Moreover, it was found that the averaged filtration efficiency of the combined multilayer materials increased from 4% to 15% when compared to those of the single layer materials. All the tested multilayer materials had their filtration efficiency greater than 95% at the aerosol droplet size of 2.42 µm. The pressure differences across the tested materials were also reported and can be considered for the level of comfort and breathability for homemade masks. It was found that as a single-layer material, non-woven fabric 1 had the smallest pressure difference because of its porous structure. The two-layer materials had 3 to 4 times pressure difference higher than the single-layer ones. The tested two-layer materials of cotton-HVAC filter and cotton fabric 1 had the smallest pressure differences and similar averaged filtration efficiency of 90%. The threelayer materials, i.e., cotton-coffee filter-cotton and cotton-coffee filter-fabric 1, had their filtration efficiency higher than 90%. However, their pressure differences were found to be 2 to 2.5 times higher than those of two-layer materials. The tested R95 mask with 5 layers had a pressure difference lower than those of the two-layer materials because it was made from the porous layers. The authors report no conflict of interests. None. Ethical approval was not required. J o u r n a l P r e -p r o o f Experimental instrumentation used in this study was funded by the U.S. Department of Energy under an Infrastructure grant of the Nuclear Energy University Program (NEUP) for nuclear research. Blake Maher, Reynaldo Chavez, and Gabriel C. Q. Tomaz contributed equally. High-resolution images of tested materials, i.e., cotton, fabric 1, micro fiber, coffee filter, HVAC filter, shower curtain, and vacuum bag. Images of commercial surgical mask (3 layers) and R95 mask (5 layers) are also included. Scale bar shown is 500 µm and the size of images presented is 2.5 × 2.5 mm 2 . J o u r n a l P r e -p r o o f Aerosol emission and superemission during human speech increase with voice loudness Uptake and effectiveness of facemask against respiratory infections at mass gatherings: a systematic review Violent expiratory events: on coughing and sneezing Sneezing and asymptomatic virus transmission Infection control survey in the hospitals to examine the role of masks and respirators for the prevention of respiratory infections in healthcare workers (hcws) A Computational and Experimental Investigation of the Human Thermal Plume On coughing and airborne droplet transmission to humans On respiratory droplets and face masks The size and the duration of air-carriage of respiratory droplets and dropletnuclei Digital particle image velocimetry (dpiv) robust phase correlation Characterizations of particle size distribution of the droplets exhaled by sneeze Aerosol technology: properties, behavior, and measurement of airborne particles Aerosol filtration efficiency of common fabrics used in respiratory cloth masks Transmission routes of respiratory viruses among humans Role of ventilation in airborne transmission of infectious agents in the built environment-a multidisciplinary systematic review Experimental investigation of the human convective boundary layer in a quiescent indoor environment The first randomized, controlled clinical trial of mask use in households to prevent respiratory virus transmission Influenza virus aerosols in human exhaled breath: particle size, culturability, and effect of surgical masks The flow physics of covid-19 Size distribution and sites of origin of droplets J o u r n a l P r e -p r o o f expelled from the human respiratory tract during expiratory activities PIV measurements of turbulent flows in a 61-pin wire-wrapped hexagonal fuel bundle Stereoscopic piv measurements of near-wall flow in a tightly packed rod bundle with wire spacers Stereoscopic particle image velocimetry measurements of flow in a rod bundle with a spacer grid and mixing vanes at a low Reynolds number Time-resolved PIV measurements in a low-aspect ratio facility of randomly packed spheres and flow analysis using modal decomposition Flowfield characteristics of a supersonic jet impinging on an inclined surface Experimental investigation of cross flow mixing in a randomly packed bed and streamwise vortex characteristics using particle image velocimetry and proper orthogonal decomposition analysis Experimental investigation of turbulent wake flows in a helically wrapped rod bundle in presence of localized blockages Turbulent flow and vortex characteristics in a blocked subchannel of a helically wrapped rod bundle Effectiveness of masks and respirators against respiratory infections in healthcare workers: A systematic review and meta-analysis Computational modeling of aerosol deposition in respiratory tract: a review Visualization of sneeze ejecta: steps of fluid fragmentation leading to respiratory droplets Evaluating the efficacy of cloth facemasks in reducing particulate matter exposure Exhalation of respiratory viruses by breathing, coughing, and talking Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises Aerosol sampling: science, standards, instrumentation and applications On air-borne infection: Study ii. droplets and droplet nuclei Airborne contagion and air hygiene. an ecological study of droplet infections Exhaled droplets due to talking and coughing Figure 6: Filtration efficiency of tested materials, including (top) single-layer and (bottom) multiple layers