key: cord-0965609-a4eb3glt authors: Liu, John; Ma, Jingyi; Ahmed, Iqbal IK; Varma, Devesh title: Implementation of a 3D Printed Custom Mask Fitter in an Ophthalmology Setting during the COVID-19 Pandemic date: 2021-03-19 journal: Can J Ophthalmol DOI: 10.1016/j.jcjo.2021.03.004 sha: efe0f19fabe0da34e3fe4c6e5d12bae142073e4a doc_id: 965609 cord_uid: a4eb3glt OBJECTIVE: To assess the effectiveness of a 3D printed custom mask fitter in lieu of N95 respirators among ophthalmologists and other eye care professionals (ECPs) who may not be prioritized to receive N95 respirators amidst the COVID-19 pandemic. METHODS: This was a proof-of-concept study from a tertiary eye care center in Oakville, Canada. All participants underwent the N95 Qualitative Fit Test with a custom mask fitter secured over an ASTM Level 3 facemask. Participants answered a 1 to 10 Likert scale questionnaire on comfort, ease of use, and feasibility of the custom mask fitter, as well as comfort of a regular facemask. RESULTS: A total of 20 participants were recruited of whom 90% (18/20) successfully passed the Fit Test. The median scores for comfort, ease of use, and everyday feasibility for the custom mask fitter were 3.5, 4.5, and 3.0, respectively, while the median score for comfort of a regular facemask was 8.5. CONCLUSION: A reusable, low-cost, 3D printed custom mask fitter is a potential effective alternative to an N95 respirator amongst ECPs but may require improvement in its design and comfort. This is especially relevant in the context of a limited supply of N95 respirators amidst a global pandemic. Eye care professionals (ECPs) face the challenge of protecting themselves and patients during the COVID-19 pandemic. To prevent transmission of the SARS-CoV-2 virus, guidelines from the Centers for Disease Control and Prevention (CDC) encourage the usage of National Institute for Occupational Safety and Health (NIOSH) approved N95 respirators during in-person interactions or high risk procedures.(1) While N95 respirators are ideal due to their airtight seal and ability to filter out 95% of all airborne viral particles, they can be difficult to obtain and are typically reserved for those involved in aerosol generating procedures (AGPs) or for those working with high-risk patient groups. Unfortunately, ECPs do not fall into these categories. Due to their limited supply, the CDC has recommended the use of a regular facemask for other healthcare providers when N95 respirators are unavailable.(1) The use of a regular facemask can be unsettling for many ECPs as the SARS-CoV-2 virus has been shown to stay viable in aerosols. (2) Aerosolized particles cannot be filtered out by a regular facemask due to its suboptimal seal and is particularly concerning for healthcare workers who consistently work in close proximity to patients. Efforts have been made to improve infection control in ophthalmologist offices, including the full use of Personal Protective Equipment (PPE) and installation of barrier shields.(3)(4) However, this is an unideal solution given the possible transmission of SARS-CoV-2 via mucous membranes. (5) A mask fitter is a reusable plastic frame placed on top of a regular facemask. The frame has a custom shape, which follows the contour of an individual's nose, midface and chin, and is secured using elastic straps. Once in place, the mask fitter provides an airtight seal around the edges of the frame. In the context of a limited supply of N95 respirators, a mask fitter could be used to meet the demand for appropriate PPE among ECPs. This study aims to assess the effectiveness of a custom mask fitter compared to an N95 respirator and describes its implementation in a large, academic, tertiary eye care centre. This was a proof-of-concept study to test the feasibility of a new type of PPE. Institutional Review Board approval was obtained from Trillium Health Partners and the protocol adhered to the tenets of the Declaration of Helsinki. Informed consent was obtained from each participant in the study. Statistical analysis was conducted on SPSS Version 24 (IBM, Armonk, NY). Participants were recruited from Prism Eye Institute, a tertiary ophthalmology center in Oakville, Ontario, Canada. Participants included technicians, front-facing administrative staff (such as front desk staff and surgical booking assistants), optometrists, ophthalmologists, and medical students. The Bellus3D (Campbell, CA) smartphone application was used on an iPhone XS (Apple, Cupertino, CA) smartphone to capture a 3D image of each person's face. For this study, each participant wore their custom mask fitter over a Level 3 mask and underwent the Fit Test. Additionally, all participants who passed the Fit Test on the first try underwent the Fit Test with only the Level 3 facemask and no custom mask fitter, to assess whether wearing the mask fitter made any difference. The same individual (J.L.) administered the Fit Test to almost all participants to ensure consistency between administrations. One participant had their N95 Fit Test administered at a hospital N95 testing centre. At the conclusion of the Fit Test, all participants answered a confidential Likert-scale questionnaire on comfort, ease of use, and everyday feasibility of the custom mask fitter, along with a question that allowed participants to leave comments and suggestions about the custom mask fitter. This is shown in Figure 3 . Table 1 outlines the participants that were enrolled in the study along with comments about the comfort level of the Mask Fitter. Of 20 participants, 18 (90%) passed the Fit Test, 13 of whom (65%) passed on the first attempt ( Figure 4 ). One female ophthalmologist passed the Fit Test on the first try but also passed the Fit Test when it was re-administered with only the fluidresistant facemask. Among the five individuals who failed on the first try, four were female. A higher proportion of male participants passed on their first try (7/8) compared to female participants (6/12), although this was not statistically significant on chi-square test (p=0.085). There was no statistically significant association between age and the likelihood of passing the Fit Test on the first try. Among all questionnaire responses ( Figure 5 ), the median scores on the Likert scales for comfort, ease of use, and everyday feasibility were 3.5, 4.5, and 3.0, respectively. A regular facemask had a median comfort score of 8.5, representing a median difference of 5.0 between the mask fitter and a regular facemask. No participant rated the mask fitter as more comfortable than the regular facemask, although one participant rated them at the same level of comfort. When stratifying by gender, there was a noticeable difference on for everyday feasibility, with male participants assigning a higher median score for feasibility than female participants (7.0 vs. 3.0), although this was not significant on Mann-Whitney U test (p=0.135). No significant associations were found with questionnaire scores and age. In the context of a global pandemic and limited PPE supplies, healthcare workers have been encouraged to reuse disposable N95 respirators.(8) However, given N95 respirators are designed for eight hours of use with the failure rate reported at 46% after 4 days of use,(9) this poses a significant risk to both healthcare providers and patients. There has also been discussion on the reuse of N95 respirators after sterilization with ionizing radiation. However, doing so causes their measured particular filtering efficiency to decline significantly, and is therefore not recommended.(10) Ideally, healthcare workers in true need of N95 respirators should be using them as they are designed and disposing of them when appropriate. A 3D-printed custom mask fitter presents a possible PPE resource for healthcare providers who are in regular close contact with patient's faces but are not involved with AGPs or do not come into contact with confirmed or suspected COVID-19 positive patients. Ophthalmologists and other ECPs are one example of this population niche. Use of the custom mask fitter by this population can preserve the limited N95 respirator supply for higher-risk healthcare workers while maintaining adequate protection for ECPs. A mask fitter or brace is also mentioned by the CDC as a way to prevent air from leaking around the edges of the mask.(11) Our proof-of-concept study demonstrates promising results for the implementation of a 3D mask fitter in an outpatient setting. Ninety percent of participants' custom mask fitters performed at the appropriate standard of an N95 respirator based on the Qualitative Fit Test. Sixty percent of participants passed on the first try while another 25% passed on their second attempt after modifying their seal. A study with N95 respirators similarly demonstrated that 44.2% of untrained healthcare workers passed the Fit Test on their first try, with another 30.2% passing on a subsequent attempt after receiving proper donning instructions. (12) The role of 3D printing to enhance PPE supplies amidst the COVID-19 pandemic has been discussed previously.(13) Custom mask fitters printed using the Bellus3D smartphone application have been informally demonstrated to enhance a peripheral seal on Level 2 and Level 3 surgical masks. However, to the best of our knowledge, our study is the first to formally investigate the effectiveness of 3D printed custom mask fitters compared to N95 respirators while exploring its feasibility. There has also been formal investigation of the use of 3D-printed mask frames to prolong the lifespan of N95 respirators.(14) However, unlike our present study, those mask frames were not custom-fitted to an individual's face. The influence of facial features on the fit of N95 respirators has been previously studied; the unique contours of a face alter how a facemask or respirator creates a seal. (15) Since the custom mask fitter is specifically designed for an individual's face, it eliminates issues associated with a "one-size-fits-all" solution. Additionally, the custom mask fitter is secured using adjustable, notched elastic straps, which allows for customization of the fit (Figure 1 ). Five out of the 7 participants who failed the Fit Test on the first try passed the test after the mask fitter was readjusted and tightened using the elastic straps. N95 respirators do not offer the same type of customization as there are only a few different models which come in a single size and have non-adjustable elastic bands. However, participants in this study did comment on the difficulty of "fiddling around" with the straps and described them as "cumbersome". Although this was not a factor directly measured in our study, spectacle-wearing participants mentioned how wearing the mask fitter prevented fogging of their glasses. Further, ophthalmologists noted that the mask reduced fogging while using the slit lamp and microscope oculars. A higher proportion of women failed the Fit Test on their first try compared to men in this study. This finding is similar to previous studies demonstrating that females were more likely to fail the Fit Test.(9) One recurring issue seen in female participants was the difficulty in securing the elastic straps when their hair was tied back. This resolved by looping the lower elastic strap from the mask fitter on top of their ponytail ( Figure 6 ). The most common comment regarding the mask fitter was discomfort in wearing it. Twenty-five percent of participants rated the mask fitter as a 1 out of 10 on comfort, and 60% rated it as 4 out of 10 or less. The most common area of discomfort was the mask fitter pushing up against the wearer's eyes -affecting one participant's ability to read. The discomfort was also felt where the frame overlay bony structures, such as the nasal bridge. While loosening the straps could increase comfort, this could compromise the seal. Improvements in design could include a thinner plastic frame around the sensitive area under the eyes, or a stronger hold around the chin to prevent the mask fitter from sliding up to the eyes. While N95 respirators have generally been shown to be comfortable,(16) a direct comparison of the custom mask fitter and N95 respirator comfort level would be useful to study in the future. The mask fitter's discomfort may be its most significant limitation as it impacts feasibility. On the questionnaire, everyday feasibility was the only question to receive scores on both extremes of the spectrum although most scores were low. Two participants rated feasibility as 10 out of 10, while 13 participants rated it as 4 out of 10 or less. The two individuals who rated feasibility as 10 out of 10 were already using their custom mask fitters on a day-to-day basis for several months. Both acknowledged that the mask fitter was initially very uncomfortable, but they became accustomed to wearing it every day. An additional limitation to using the custom mask fitter involves the type of regular facemask required. Although the seal around a mask is an important aspect of preventing aerosol transmission, the mask's physical material is another factor. In this study, the mask fitter was placed over an ASTM Level 3 facemask. The specific ASTM Level 3 facemask used in this study has an advertised particle filtration efficiency (PFE) of ≥99% at 0.1 microns and bacterial filtration efficiency (BFE) of ≥99% at 3 microns.(17) A NIOSH-approved N95 Respirator sold by the same manufacturer has the exact same PFE and BFE.(18) Prior to commencing the study, the authors tested the mask fitter over an ASTM Level 1 mask and found it would fail the qualitative Fit Test. Thus, ASTM Level 3 masks are required to successfully mimic an N95 respirator with the mask fitter, which are more costly than ASTM Level 1 masks. ASTM Level 2 masks were not tested and present an opportunity for further investigation. Finally, there are imitations of the qualitative Fit Test itself, which has not been shown to be an accurate representation of the respirator's ability to filter all particles.(14) Furthermore, as participants were aware of the goals of this study, there could be an element of participant bias. Additionally, the Likert scales provided in this study ranged from 1 to 10. A scale from 0 to 10 would have been more useful as Likert scales typically have an odd number of selections to allow a midpoint selection. Finally, with its small sample size of just 20 participants, these results are not generalizable to large populations and should be interpreted within its scope as a proof-of-concept study. Overall, the 3D printed custom mask fitter is a potential option for ECPs seeking more robust PPE given the current limited N95 respirator supply. As it is reusable, cost-effective, and custom-designed to each individual, it offers advantages over N95 respirators and may even be further investigated a new form of PPE after the COVID-19 pandemic resolves. However, the custom mask fitter requires further investigation to test its effectiveness through quantitative means, and further design adjustments to improve its comfort, user-friendliness, and everyday feasibility. In its current state, it cannot replace the N95 respirator, but may provide an alternative PPE solution when N95 supplies are limited. Equinox: C 17. Genentech: C 18. Glaukos: C, R 19. Gore: C 20. InjectSense: C 21. Iridex: C 22. iStar: C 23. Ivantis: C, R 24. Johnson & Johnson Vision: C, S, R 25. KeLoTec: C 26. LayerBio: C 27. Leica Microsystems: C 28. Long Bridge Medical, Inc: C 29. MicroOptx: C 30. MST Surgical: C, S 31. Mundipharma: S 32. Mynosys: C 33. New World Medical: C, R 34. Ocular Instruments: C 35. Ocular Therapeutix: C 36. Omega Ophthalmics: C 37. PolyActiva: C 38. Sanoculis: C 39. Santen: C, R 40. Science Based Health: C 41. Sight Sciences: C 42. Smartlens, Inc: C 43. Stroma: C 44. Thea Pharma: C 45. ViaLase: C 46. Vizzario: C Devesh Varma: Consultant/Consulting Fees from Allergan and Alcon None Iqbal IK Ahmed:C-Consultant/Consulting Fees S-Speakers Honoraria R-Research Grant/Support 1. Aequus: C 2. Aerie Pharmaceuticals: C, R 3. Akorn: C 4. Alcon: C,S,R 5. Allergan: C,S,R 6. ArcScan: C 7. Bausch Health: C 8. Beaver Visitec: C 9. Beyeonics: C 10. Camras Vision: C, R 11. Carl Zeiss Meditec: C,S 12 Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1 Preparedness among Ophthalmologists: During and Beyond the COVID-19 Pandemic Efficacy of slit lamp breath shields 2019-nCoV transmission through the ocular surface must not be ignored. The Lancet How to Make Bellus3D's Face Mask Fitter | Occupational Safety and Health Administration The National Institute for Occupational Safety and Health. Recommended Guidance for Extended Use and Limited Reuse of N95 Filtering Facepiece Respirators in Healthcare Settings | NIOSH | CDC Probability of fit failure with reuse of N95 mask respirators Disposable N95 Masks Pass Qualitative Fit-Test But Have Decreased Filtration Efficiency after Cobalt-60 Gamma Irradiation Respirator-Fit Testing: Does It Ensure the Protection of Healthcare Workers Against Respirable Particles Carrying Pathogens? Infect Control Hosp Epidemiol The role of 3D printing during COVID-19 pandemic: a review 3D Printed frames to enable reuse and improve the fit of N95 and KN95 respirators [Internet]. Occupational and Environmental Health Characterization of small-to-medium head-and-face dimensions for developing respirator fit test panels and evaluating fit of filtering facepiece respirators with different faceseal design FLUIDSHIELD N95 Particulate Filter Respirator and Surgical Mask | Halyard Health