key: cord-0964696-st7n3pnq authors: Svigelj, Rossella; Dossi, Nicolò; Grazioli, Cristian; Toniolo, Rosanna title: Paper-based aptamer-antibody biosensor for gluten detection in a deep eutectic solvent (DES) date: 2021-10-06 journal: Anal Bioanal Chem DOI: 10.1007/s00216-021-03653-5 sha: 69c8c8478ef0b8ce4d5000e466199585116a350c doc_id: 964696 cord_uid: st7n3pnq Paper has been widely employed as cheap material for the development of a great number of sensors such as pregnancy tests, strips to measure blood sugar, and COVID-19 rapid tests. The need for new low-cost analytical devices is growing, and consequently the use of these platforms will be extended to different assays, both for the final consumer and within laboratories. This work describes a paper-based electrochemical sensing platform that uses a paper disc conveniently modified with recognition molecules and a screen-printed carbon electrode (SPCE) to achieve the detection of gluten in a deep eutectic solvent (DES). This is the first method coupling a paper biosensor based on aptamers and antibodies with the DES ethaline. Ethaline proved to be an excellent extraction medium allowing the determination of very low gluten concentrations. The biosensor is appropriate for the determination of gluten with a limit of detection (LOD) of 0.2 mg L(−1) of sample; it can detect gluten extracted in DES with a dynamic range between 0.2 and 20 mg L(−1) and an intra-assay coefficient of 10.69%. This approach can be of great interest for highly gluten-sensitive people, who suffer from ingestion of gluten quantities well below the legal limit, which is 20 parts per million in foods labeled gluten-free and for which highly sensitive devices are essential. [Image: see text] Paper displays interesting physical and physicochemical properties, such as adsorption properties, capillary action, and high surface-to-volume ratio, and allows immobilization of biomolecules [1] . It has been applied in many different research fields, such as in the development of sensors, microfluidic devices, and point-of-care(POC) diagnostic tools [2] . In recent decades, POC tests based on paper have been developed for glucose and other important bioactive molecules [3, 4] . Currently, paper continues to be employed as material for the production of widely used sensors such as pregnancy tests, strips to measure blood sugar, and COVID-19 rapid tests [5, 6] . Besides paper strips, patterned paper has also been used as a platform for the implementation of portable, low-cost bioassays aimed at use in developing countries [7, 8] . In addition, electrochemical detection for paper-based microfluidics was also proposed for the determination of low levels of analytes in biological samples and complex sample matrixes [9] . The need for new low-cost analytical devices is growing, and the use of these platforms will be extended to different assays both for the final consumer and within laboratories [10, 11] . Among the most relevant points in the use of this material, there are advantages such as biocompatibility and biodegradability, low cost, and ease of production [12] . These aspects have led to a growing interest in the development of paper-based analytical devices (PADs), such as smart labels [13] , gas sensors [14, 15] , and sensors combining electrochemical and visual readouts [16] . PADs have successfully found application in diagnostics [4] , environmental monitoring [17] , and food control [18] . To date, paper-based gluten sensors such as lateral flow devices are commercially available, indicating the presence or absence of gluten, with a limit of detection (LOD) of around 4 mg L −1 . They can be used for potentially contaminated surfaces and to check for gluten contamination of raw or processed materials [19] , but they are not suitable for sensitive gluten quantification. As is well known, celiac disease is triggered by the ingestion of gluten in people predisposed to the disease [20] . In the future, it will be increasingly necessary for consumers to monitor food directly at home. Thus, the development of low-cost platforms that are easy to use and highly sensitive is of growing interest [18] . Gluten is composed of a complex mixture of waterinsoluble storage proteins; among them, gliadin is commonly used as the analytical target to quantify gluten in food. The most commonly used solvent in gluten quantification methods is a 60% (v/v) ethanol-water solution; however, this method is not able to completely extract gluten from processed food [21] . Reducing and disaggregating agents have also been used in combination with alcohol solutions to overcome this problem [22, 23] . Nevertheless, both 2-mercaptoethanol and denaturants used in the extraction cocktails can interfere in the subsequent protein recognition, affecting the quantification results [24] . Thus, substantial sample dilutions are usually needed. The problem regarding the complete extraction of gluten proteins from food makes the determination of gluten a continuing challenge and an open topic in which research advances are needed [25] . Recently, an alternative method of extraction using a deep eutectic solvent (DES) was proposed [26] . This approach allows the direct measurement of the extracted sample in the DES ethaline (choline chloride:ethylene glycol, 1:2), exploiting the biocompatibility of the eutectic solvent with molecules such as DNA and antibodies. DESs are formed thanks to the interaction between a hydrogen bond donor (HBD) and a hydrogen bond acceptor (HBA) [27] . They present low vapor pressure and a high ability to dissolve molecules of different nature; they are green, easy to produce, and low-cost [28, 29] . For these reasons, the use of DESs is expanding in different fields [30] [31] [32] [33] , in fact, in recent years, they have been applied in the extraction of various molecules [34] [35] [36] and in different research areas including organic synthesis, electrochemistry, and biocatalysis [37] [38] [39] . Here we describe a paper-based electrochemical sensing platform that uses a paper disc conveniently modified with recognition molecules and a screen-printed electrode to achieve the detection of gluten in DES. This analytical platform allows the use of a single screen-printed carbon electrode (SPCE) for the analysis of several paper discs. This provides the possibility for reduced use of SPCEs and a considerable decrease in the cost of each measurement. This sandwich-type electrochemical biosensor exploits an aptamer and antibody pair for the detection of gluten. Aptamer-antibody sandwich assays show enhanced sensitivity and specificity [40, 41] . For this reason, a Gli4-T aptamer was employed as the capturing element, while a 401/21 antibody was used as detection probe. This platform was designed to provide a low-cost and sensitive tool for the fraction of highly gluten-sensitive people, who suffer from ingestion of gluten quantities well below the legal limit which is 20 parts per million in foods labeled gluten-free and for which highly sensitive devices are essential [42] . All chemicals used were of analytical reagent grade and were employed without further purification. HPLC-purified 5′tagged (-NH 2 ) aptamers were obtained from Tema Ricerca (Bologna, Italy). The Gli4 complete aptamer sequence and the truncated sequence are shown in Table 1 . The 401/21 antibody and enzyme-linked immunosorbent assay (ELISA) kit were supplied by Bio-Check (UK). Gliadin standard was kindly provided by the Prolamin Working Group (PWG). Ethaline was supplied by Scionix Ltd. (London, UK) and employed as received ( Table 2) . Salts for buffer solutions, bovine serum albumin (BSA), 1 M Tris/HCl pH 7.4, phosphate-buffered saline (PBS) 10×, sodium alginate, 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC), Nh y d r o x y s u c c i n i m i d e ( N H S ) , a n d a 3 , 3 ′ , 5 , 5 ′tetramethylbenzidine (TMB) liquid substrate system for ELISA solution were obtained from Sigma-Aldrich (Italy). With regard to filter paper, 50 cm × 50 cm foils, 67 g/m 2 , 0.13 mm thick, were purchased from Labor (Cordenons, Italy) and 0.18 mm-thick paper from Whatman (Maidstone, UK). High-purity deionized water (purified by an Elgastat UHQ PS system, Elga, High Wycombe, UK) was used for all washing operations. Paper-based biosensor assembly Filter paper was cut into discs of 6 mm. As shown in Fig. 1 , discs were soaked in 10 μL of sodium alginate (0.05% w/v) at 4°C overnight. After a washing step, the polysaccharidemodified paper was ready for use. Then Next, a solution of the anti-gluten antibody was incubated for 10 min. After each step, discs were washed with buffer solution. Finally, electrochemical transduction was performed by adding 40 μL of TMB solution, and after 3 min of the enzymatic reaction the paper disc was transferred onto the SPCE and measured by chronoamperometry at 0 V (Figure1). All electrochemical measurements were performed with a µAutolabIII/FRA2 potentiostat controlled by Nova 2.1 software (EcoChemie, the Netherlands). Disposable screen- To prevent contamination, samples were prepared in a laboratory separated from where analyses were performed. Gluten was extracted with ethaline from corn flakes, and a gluten-free flour purchased from a local supermarket. A 0.1 g sample of the obtained powder was extracted in vials with 1 mL of pure DES [43] . Vials were shaken in a vortex for 2 min, and then they were left at 55°C for 45 min. Next, samples were shaken again for 2 min and centrifuged for 10 min at 5000 rpm. Depending on the level of gluten, the supernatant was applied directly on the electrode surface or properly diluted in 100% DES before the analysis. Initially, the modification of the SPCE with the paper disc was evaluated with cyclic voltammetry at different scan rates (25, 50 , 100 mV/s) using the redox probe ferrocyanide 2 mM in PBS buffer and KCl 3 mM as supporting electrolyte. Cyclic voltammograms recorded at the bare SPCE and filter papermodified SPCE and Whatman paper-modified SPCE are presented in Fig. 2 . A well-defined and quasi-reversible redox process was found for the redox couple [Fe(CN) 6 ] 4− / [Fe(CN) 6 ] 3− for all the setups, with a peak-to-peak separation (ΔE p ) recorded at 50 mV/s of 152 mV on bare SPCE, 91 mV on filter paper, and 110 mV on Whatman paper. These results show that the electron transfer on paper-modified SPCE is very similar to that recorded at bare SPCE, suggesting that good electrolytic contact was achieved. However, the The principle of the biosensor is illustrated in Fig. 1 . In this approach, the truncated aptamer Gli4-T was employed as capture element while the 401/21 antibody was employed as the signaling element. In a previous work, the process of truncation of non-essential nucleotides was reported to improve the accessibility of the target to the aptamer, allowing the formation of a stronger aptamer-target complex [44] . Gli4-T is the truncated aptamer derived from Gli4 which preserves a motif capable of effectively binding gliadin (Fig. 3) [45, 46] . Gli4-T has a dissociation constant (K d ) of 148 ± 8 nM in aqueous buffer, and a K d of 515 ± 144 nM in ethaline [43] . The paper-based sensor was designed using common laboratory filter paper cut into discs of 6 mm. A polysaccharide with multiple functional groups was employed as surface modifier for paper on which the aptamer was covalently immobilized [47] . Sodium alginate was dropped onto the paper, and the carboxyl groups were then activated by EDC/NHS and subsequently the amino-modified aptamer was immobilized. After blocking the surface with BSA, PWG-gliadin solutions were tested in the range of 0.1-10 mg L −1 . Lastly, the antibody labeled with horseradish peroxidase (HRP) enzyme was incubated and TMB substrate added. The enzyme catalyzed the oxidation of TMB in the presence of hydrogen peroxide, then the chronoamperometric detection was performed at 0 V. Both filter paper and Whatman paper were tested in the development of the assay. As can be observed in Fig. 4 , at lower concentrations of analyte there was little difference in the performance, but at higher concentrations of gliadin (1 mg L −1 ), the common filter paper showed a higher signal ratio, proving to be the best option for the assay development. For the sake of comparison, calibration curves were conducted both in aqueous buffer and in ethaline. As can be seen in Fig. 5 , both calibration curves fitted to the Hill function, with a correlation of 0.999 in aqueous buffer and 0.997 in ethaline. The calibration in DES allowed to expand the measurement to 10 mg L −1 , while the calibration in aqueous buffer already reached the saturation at a concentration of 2 mg L −1 of gliadin. The response of the biosensor was determined in a range from 0.1 to 1 mg L −1 of gliadin in aqueous buffer and from 0.1 to 10 mg L −1 in ethaline. The reproducibility of the method was very good; the calculated intra-assay CV % in aqueous buffer was 6.64 The results obtained with this sandwich sensor proved to be interesting for the sensitive, low-cost detection of gluten. In addition, the obtained LOD, calculated as three times the standard deviation of the blank signal divided by the slope calculated for the linear dynamic range, is 0.2 mg L −1 of gluten, which successfully competes with the assays described in the literature and on the market, as can be seen in Table 3 . The paper-based biosensor here developed can be applied in the determination of gluten in gluten-free foods to provide more information and safety to celiac people. To demonstrate its applicability to gluten quantification, two real food samples were analyzed. We tested a gluten-free flour sample and a corn flakes sample using ethaline for the extraction. Accordingly, we also performed the quantification with an ELISA, and the results are compared in Table 4 . The quantification of gluten in the flour sample with the paper-based method gave a gluten content of 2.68 ± 0.01 mg L −1 , a result comparable to the one obtained with the classic ELISA (2.3 ± 0.1 mg L −1 ) of gluten. Moreover, the sensor also worked well for the corn flakes sample with a higher gluten content (21.33 ± 0.08 mg L −1 ) in good agreement with the results obtained from the ELISA test (20.50 ± 0.09 mg L −1 ). These results proved that this method can be successfully used for the reliable quantification of gluten in foods labeled as gluten-free and can be a valid alternative to current methods. Moreover, to ensure the effectiveness and applicability of the method, we evaluated the possible interference caused by other proteins. For this purpose, chickpea flour with high protein content was used. After extraction with ethaline, the sample was tested with the paper-based sensor. This naturally gluten-free sample gave comparable signals as blanks, as can be seen in Table 5 , demonstrating that this method shows no interference from the presence of other proteins in the sample. In this work we have designed a simple, low-cost, and easy-touse biosensor. This is the first method coupling a paper biosensor based on aptamers and antibodies with a DES. We coupled a paper disc with recognition biomolecules for the electrochemical determination of gluten extracted in DES, providing a cheap detection device in comparison with traditional methods. This approach could enable a substantial advance in the analysis of gluten, being very economical and sensitive at the same time. Very important aspects to take into consideration are the use of biodegradable materials such as paper and DES and the advantage of using a single SPCE for a whole set of measures. Moreover, this biosensor has proven to be appropriate for the determination of very low concentrations of gluten, with a LOD of 0.2 mg L −1 of sample. The ELISA R5 Mendez method remains the only method recommended by the Codex for gluten analysis; however, all advances in this area can bring important improvements in the quantification of gluten. This approach can be of great interest for highly gluten-sensitive people who suffer from ingestion of gluten quantities well below the legal limit and for whom highly sensitive devices are essential. Funding Open access funding provided by Università degli Studi di Udine within the CRUI-CARE Agreement. Data availability Not applicable. Code availability Not applicable. Conflicts of Interest The authors declare no conflict of interest. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. A Review on Microfluidic Paper-Based Analytical Devices for Glucose Detection Paper-Based Screen-Printed Electrodes: A New Generation of Low-Cost Electroanalytical Platforms Biosensors: sense and sensibility Advances in paper-basedpoint-of-care diagnostics Chapter Eleven -Paper-Based Electrochemical Devices in Biomedical Field: Recent Advances and Perspectives Point-ofcare test system for detection of immunoglobulin-G and -M against nucleocapsid protein and spike glycoprotein of SARS-CoV-2 Patterned paper as a platform for inexpensive, low-volume, portable bioassays Paper and Other Fibrous Materials-A Complete Platform for Biosensing Applications Electrochemical detection for paper-based microfluidics Sensors as green tools in analytical chemistry Perspective-Paper-Based Biosensors: Trending Topic in Clinical Diagnostics Developments and Commercialization Paper-based chemical and biological sensors: engineering aspects A colorimetric paper-based smart label soaked with a deep-eutectic solvent for the detection of malondialdehyde Modified screen printed electrode suitable for electrochemical measurements in gas phase Amperometric sniffer for volatile amines based on papersupported room temperature ionic liquids enabling rapid assessment of fish spoilage Electrochemical/visualdual-readout aptasensor for Ochratoxin A detection integrated into a miniaturized paper-based analytical device Eco-friendly electrochemical lab-on-paper for heavy metal detection Novel paper-based electroanalytical tools for food surveillance Validation of a qualitative R5 dip-stick for gluten detection with a new mathematical-statistical approach The biochemical basis of celiac disease Effect of hydrostatic pressure and temperature on the chemical and functional properties of wheat gluten: studies on gluten, gliadin and glutenin Recent developments in analytical methods for tracing gluten Development of a general procedure for complete extraction of gliadins for heat processed and unheated foods Interference of denaturing and reducing agents on the antigen/antibody interaction. Impact on the performance of quantitative immunoassays in gliadin analysis Recent progress in analytical method development to ensure the safety of gluten-free foods for celiac disease patients An effective gluten extraction method exploiting pure choline chloride-based deep eutectic solvents (ChCl-DESs) Deep eutectic solvents formed between choline chloride and carboxylic acids: versatile alternatives to ionic liquids Deep Eutectic Solvents: A Review of Fundamentals and Applications Deep eutectic solvents: syntheses, properties and applications Green solvents for sample preparation in analytical chemistry Eutectics: formation, properties, and applications Recent applications of deep eutectic solvents in environmental analysis Deep eutectic solvents (DESs) and their application in biosensor development Evaluation of alcohol-based deep eutectic solvent in extraction and determination of flavonoids with response surface methodology optimization Comprehensive evaluation of deep eutectic solvents in extraction of bioactive natural products Application of natural deep eutectic solvents to the extraction of anthocyanins from Catharanthus roseus with high extractability and stability replacing conventional organic solvents Recent advances in the application of deep eutectic solvents as sustainable media as well as catalysts in organic reactions A deep eutectic solvent-based Amperometric sensor for the detection of low oxygen contents in gaseous atmospheres Deep eutectic solvents for redox biocatalysis Aptamer-based sandwich-type biosensors Electrochemical detection of thrombin by sandwich approach using antibody and aptamer Immunochemical detection methods for gluten in food products: where do we go from Here? Truncated aptamers as selective receptors in a gluten sensor supporting direct measurement in a deep eutectic solvent Rational truncation of aptamer for cross-species application to detect krait envenomation Aptamer binding to celiac diseasetriggering hydrophobic proteins: a sensitive gluten detection approach Selection of anti-gluten DNA aptamers in a deep eutectic solvent A zero-step functionalization on paper-based biosensing platform for covalent biomolecule immobilization A new label-free impedimetric aptasensor for gluten detection Impedimetric sensing of the immuno-enzymatic reaction of gliadin with a collagen-modified electrode Analyzing Gluten Content in Various Food Products Using Different Types of The feasibility of harmonizing gluten ELISA measurements Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations