key: cord-0963779-x3frx1vb authors: Cieśla, K.; Wolak, T.; Lorens, A.; Mentzel, M.; Skarżyński, H.; Amedi, A. title: Effects of training and using an audio-tactile sensory substitution device on speech-in-noise understanding date: 2022-02-25 journal: Sci Rep DOI: 10.1038/s41598-022-06855-8 sha: 6e96a4ea65c8818cae0ce3485ca532bf6fd66b87 doc_id: 963779 cord_uid: x3frx1vb Understanding speech in background noise is challenging. Wearing face-masks, imposed by the COVID19-pandemics, makes it even harder. We developed a multi-sensory setup, including a sensory substitution device (SSD) that can deliver speech simultaneously through audition and as vibrations on the fingertips. The vibrations correspond to low frequencies extracted from the speech input. We trained two groups of non-native English speakers in understanding distorted speech in noise. After a short session (30–45 min) of repeating sentences, with or without concurrent matching vibrations, we showed comparable mean group improvement of 14–16 dB in Speech Reception Threshold (SRT) in two test conditions, i.e., when the participants were asked to repeat sentences only from hearing and also when matching vibrations on fingertips were present. This is a very strong effect, if one considers that a 10 dB difference corresponds to doubling of the perceived loudness. The number of sentence repetitions needed for both types of training to complete the task was comparable. Meanwhile, the mean group SNR for the audio-tactile training (14.7 ± 8.7) was significantly lower (harder) than for the auditory training (23.9 ± 11.8), which indicates a potential facilitating effect of the added vibrations. In addition, both before and after training most of the participants (70–80%) showed better performance (by mean 4–6 dB) in speech-in-noise understanding when the audio sentences were accompanied with matching vibrations. This is the same magnitude of multisensory benefit that we reported, with no training at all, in our previous study using the same experimental procedures. After training, performance in this test condition was also best in both groups (SRT ~ 2 dB). The least significant effect of both training types was found in the third test condition, i.e. when participants were repeating sentences accompanied with non-matching tactile vibrations and the performance in this condition was also poorest after training. The results indicate that both types of training may remove some level of difficulty in sound perception, which might enable a more proper use of speech inputs delivered via vibrotactile stimulation. We discuss the implications of these novel findings with respect to basic science. In particular, we show that even in adulthood, i.e. long after the classical “critical periods” of development have passed, a new pairing between a certain computation (here, speech processing) and an atypical sensory modality (here, touch) can be established and trained, and that this process can be rapid and intuitive. We further present possible applications of our training program and the SSD for auditory rehabilitation in patients with hearing (and sight) deficits, as well as healthy individuals in suboptimal acoustic situations. multiple speakers talking simultaneously [3] [4] [5] . With visual cues present, including both lip-reading and watching gestures, understanding speech against noise has been consistently found to improve, in both healthy individuals and in patients with hearing loss 1, [6] [7] [8] [9] [10] . In today's modern society challenging acoustic conditions occur increasingly more often, including exposure to multiple concurrent auditory streams and almost constant exposure to noise. At the same time, the prevalence of hearing loss is growing (WHO 2020), condition which if left untreated, can accelerate cognitive decline, social isolation and depression [11] [12] [13] [14] . In addition, many users of modern hearing aids and cochlear implants complain that their devices fail to effectively compensate for their hearing loss when they are exposed to ambiguous acoustic situations [15] [16] [17] . All this indicates the importance of developing novel training methods and devices that can be employed to improve communication. Especially solutions combining multisensory inputs are appealing, as increasingly more experimental studies [18] [19] [20] and conceptual works point to the superiority of multisensory over unisensory environments for learning and sensory recovery [21] [22] [23] [24] [25] . Multisensory speech training regimes that complement audition with vision have been found successful 10, [25] [26] [27] , including in rehabilitation of patients with hearing aids (HA) and/or cochlear implants (CI), by adding speech reading, gestures or sign language cues 1, 6, 28 . Several recent works showed benefits of providing tactile (instead of visual) stimulation corresponding to low-frequencies of speech, to improve comprehension of distorted auditory speech in noise, including our own findings [29] [30] [31] . The idea of adding low-frequency tactile information to improve speech perception was first inspired by studies showing the benefit of complementing degraded speech signals with low-frequency auditory information (e.g. when using both a hearing aid and a cochlear implant), which carries pitch information and thus helps segregate auditory streams, including discriminating between speakers 29, 32, 33 . Applying a combination of auditory and tactile stimulation in assistive communication devices is an interesting and novel approach, that can prove useful especially if access to visual cues during communication is limited or absent (which apart from the discussed cases is also the every-day reality of the visually impaired). Audition and touch share some key features, such that both use mechanoreceptors to encode vibration in a common range of low frequencies (approximately 50 Hz to 700 Hz). Therefore, vibrotactile and auditory information can be naturally perceived as an interleaved signal, which is then also processed in partially shared brain regions, in both hearing participants as well as in congenitally deaf [34] [35] [36] [37] [38] [39] [40] . Auditory and vibrotactile inputs are also often experienced together, such as when a mobile phone is ringing and buzzing or when driving a car. Given these similarities between senses, we developed an in-house audio-to-touch (assistive) Sensory Substitution Device (SSD). SSDs convey information typically delivered by one sensory modality (e.g., vision) through a different sensory modality (audition, touch) using specific translation algorithms that can be learned by the user [41] [42] [43] [44] . A classic example is a chair developed by Prof Bach-Y-Rita in 1969, that delivered a visual image to the back of its blind users, through patterns of vibration 43 . In our first work with the audio-to-touch SSD we showed immediate and robust improvement of 6 dB on average in healthy subjects in speech-in-noise understanding (Speech Reception Threshold, SRT), when auditory speech was complemented with low-frequency tactile vibrations delivered on fingertips 31 . Importantly, in our previous experiment the improvement occurred without applying any training. This immediate effect was in contrast to a number of other works using other SSDs, including devices translating vision to sound or vision to touch, which required hours of training and/or prolonged use to yield benefits, probably due to the complexity of the applied algorithms 43,45-49 . In the current study we sought to investigate whether we can replicate our previous findings of showing improved understanding of distorted speech in noise when the signal is accompanied with concurrent vibrations on fingertips. We also applied two types of training, unisensory auditory training and multisensory audio-tactile training, to see whether performance can improve even further. We also wanted to determine how the training will impact understanding of completely novel sentences in three test conditions, with or without concurrent matching (corresponding to the audio sentence) or non-matching vibrations delivered on fingertips with our SSD. To our knowledge, this is the first study exploring speech-to-touch sensory substitution that also applied a control training session and a control multisensory speech test condition 29, 30 . We chose to study non-native English speakers with good levels of English in order to take advantage of the inverse effectiveness principle of multisensory integration, according to which multisensory enhancement (here, adding matching tactile input to a degraded auditory speech signal) is strongest when the ratio is lowest between senses [50] [51] [52] . In the current study we made the auditory task challenging by introducing distortions to resemble hearing through a cochlear implant (noise-vocoding 30, 53 ) , presenting the sentences with background speech noise and in addition using a non-native language of the participants. Several studies have shown that listeners have more difficulty perceiving non-native speech in noise than the native speakers, despite similar performance in a quiet environment 10, [54] [55] [56] , and at the same time might more readily benefit from multisensory speech cues 10, 27, [56] [57] [58] . The objectives of this study are important for both practical reasons and for enhancing basic science understanding of multisensory processing and cross-modal integration. The audio-tactile multisensory context of speech using audio-tactile sensory substitution is especially intriguing, as it is completely novel to the study participants and only experienced during participation in the experiment. This contrasts with audio-visual speech, i.e. listening to speech and lip reading/observing gestures at the same time, which is the natural multisensory input to which we are all exposed from early development and throughout the lifetime (see review in 9 ). If our SSD solution and training proves effective in the multisensory context, this will indicate that even in adulthood a new pairing between a certain computation (here, speech processing) and an atypical sensory modality (here, touch) can be built. This effect can expand the classical notion of closed "critical periods" for sensory development in childhood. We hypothesized that with speech being the most relevant biological signal for human and due to the similarities between the two employed senses to convey it, we will see rapid and profound perceptual effects of training. We furthermore hypothesized that multisensory audio-tactile training www.nature.com/scientificreports/ will be superior to unisensory training, through cross-modal enhancement. Potential applications of our set-up include auditory speech rehabilitation in the hearing impaired (but also training audio-tactile integration in late visual impairments 59 ) and assisting healthy individuals in suboptimal acoustic contexts, including when learning a foreign language, listening to music or talking on the phone. Material. Forty (N = 40) participants took part in the study (19 male, 21 female, age: M = 26.67, SD = 3.48 years), mostly University students or their friends. All participants completed an in-house questionnaire asking basic questions about their Hebrew and English language background. They were all native Hebrew speakers (born in Israel and learned Hebrew as their first language), right-handed, and reported no history of neurological or neurodevelopmental impairments. For all participants English was their first foreign language and they knew it well (their total mean self-rated English proficiency was 4.26 ± 0.35 on the scale from 1 to 5, see Table 1 ) and started to learn English at a relatively young age (to speak English at a mean age of 6.85 ± 2.53 years; 95% started learning before age 9 and 57% before age 7; to write in English at the mean age of 7.7 ± 1.81 years, with 92.5% before age 9). They communicated in English approximately 20% of a regular day (mean group results, Table 1 ). All participants confirmed that they had age-normal hearing (pure tone audiometry thresholds from their personal medical records < 20 dB for 0.125-8 kHz). In order to examine the effects of applying two types of training of speech understanding, unisensory and multisensory, the participants were divided into two groups of 20 participants. The groups were of similar age and gender composition, English language proficiency and age when they started learning English (see Table 1 for results of F-tests ad Chi 2 tests). Group 1 (N = 20, 10 male/10 female; mean age = 27.8 ± 3.53) participated in a multisensory (audio-tactile) training session, in which they were repeating sentences presented to them both through headphones and as a corresponding matching vibrotactile input on fingertips (see "Methods" for the details of the procedure). Group 2 had training with the sentences presented solely through audition (N = 20, 11 male/9 female; mean age = 25.55 ± 3.11). Method. The experimental set-up and the speech-to-touch SSD. To run the study, we developed a dedicated MatLab application (version R016a, The MathWorks Inc., Natick, MA, USA) with a user-friendly GUI (see Fig. 1B ) that can be used to both establish SRT (Speech Reception Threshold, SRT, i.e., signal-to-noise ratio for 50% understanding) for a tested individual, as well as generate speech stimuli at certain signal-to-noise ratios for the training session, with or without concurrent vibrations delivered on fingertips. Our in-house audio-to-touch Sensory Substitution Device (SSD) (designed in collaboration with the World Hearing Centre in Warsaw, Poland and Neurodevice company [http:// www. neuro device. pl/ en]) was used to deliver the speech signal as tactile vibration. The main part of the SSD is a vibrating interface with two piezoelectric plates, to simultaneously provide vibrotactile inputs on the index and middle finger of the dominant hand (Fig. 1A) . The interface is connected to a controller powered from a socket of 230 V and vibration is delivered from a PC. The interface's enclosure is isolated with foam to ensure some soundproofing and dampening. For auditory stimulation we used noisecancelling headphones (BOSE QC35 IIA). Both the SSD and the headphones were connected to the PC through a 5.1 soundcard (Creative Labs, SB1095). www.nature.com/scientificreports/ The speech stimuli. As speech stimuli we used recordings of the Hearing in Noise Test (HINT) sentences 60 originally organized in 28 equivalent lists of 10 sentences that have been normalized for naturalness, difficulty, and intelligibility [in our database recordings of two sentences were missing, i.e. we had 278]. All sentences were of similar length (2.5-2.8 s) and conveyed a simple semantic content, such as e.g. "The boy fell from the window" or "It's getting cold in here". The energy of each sentence was normalized with a standard RMS procedure, peaks of energy were leveled to − 6 dB and the sounds were stored as 16-bit 44.1 kHz digital waveforms. Next, the sentences were noise-vocoded to resemble stimulation through a cochlear implant (CI) using an in-house algorithm developed at the Institute of Physiology and Pathology of Hearing 53 . The process of vocoding mainly involved band-pass filtering to 8 channels and modulation of the signal with a narrowband noise (the details of the applied algorithm were described in our previous work 31 ). For all the testing conditions and during the Training session, the sentences were presented against background speech noise (International Female Fluctuating Noise, IFFN; https:// www. ehima. com/). The experiment timeline. After a short practice session, all participants took part in three tests of speech-innoise comprehension to establish their individual SRTs, once before and once after a short training session, as depicted in Fig. 2 . Practice. All participants started with a brief practice session of listening to 2-4 different noise-vocoded and non-vocoded sentences from the English HINT sentence database 60 , with and without accompanying background noise and/or vibrations on fingertips, only to familiarize themselves with the study setting and the task. Speech reception threshold tests. In the actual tests, as well as in the training session, the task of the participants was to repeat vocoded sentences in speech background noise. There were 3 test conditions, both before and after training, all with sentences presented in the headphones: (a) with no concurrent vibration delivered www.nature.com/scientificreports/ on fingertips (Audio Only, A), (b) together with low frequencies including the fundamental frequency (f0) extracted from the heard sentence, i.e. matching f0, delivered as vibration on fingertips (hereafter Audio-Tactile Matching, ATm), (c) together with low frequencies, including f0 not corresponding, i.e. non-matching, to the heard sentence, delivered as vibration on fingertips (hereafter, Audio-Tactile non-Matching, ATnm). Both study groups participated in all test conditions. In both groups, the A condition always came first, followed by the ATm condition in 10 out of 20 participants (A, ATm, ATnm), and by the ATnm condition in the remaining 10 participants (A, ATnm, ATm). As described in our previous work 31 , f0 had been earlier extracted from each original sentence derived from the English HINT database, using the STRAIGHT algorithm that was further improved. For the audio-tactile matching test condition the vibrotactile input represented low frequencies including f0 of the sentence presented in the headphones. For the audio-tactile non-matching test condition, the vibrotactile input represented low frequencies including f0 of another sentence randomly selected by a MATLAB algorithm from the HINT database. For each test we always used 20 different sentences (2 lists) that were presented in a fixed order of their appearance on the list. The difficulty level was adapted based on individual performance (2 dB up-2 dB down) during task performance. The outcome measure of each speech test was Speech Reception Threshold (SRT) of the target sentences against background noise, calculated as a mean of 5 last reversals. The applied adaptive procedure is typical for clinical settings when assessing speech understanding in hearing aid and/or cochlear implant users 61 . After the training session participants performed the second round of 3 speech test conditions in the same order as the first set of tests (A, ATm, ATnm or A, ATnm, ATm). Training. After the initial series of 3 tests of speech understanding each person participated in a short training session. The training consisted of repeating 148 vocoded sentences in background speech noise. In Group 1 each sentence presented through the headphones during training was accompanied with matching low-frequency vibrotactile inputs delivered on fingertips of two fingers via our SSD. Group 2 participated in a training session with sentences presented through audition only. The SNR during training corresponded to the SRT value of a given person established before training for a given test condition and was kept constant during the whole training session. In Group 1 it was the SRT value established in the pre-training test condition involving auditory and matching tactile input (ATm). In Group 2, the SRT for the training corresponded to the SRT obtained by the person in the pre-training Audio only (A) test condition. During the training session (30-50 min in duration), each sentence was presented up to 3 times in a row and if the person was unable to repeat it correctly, the sentence was presented as text on the PC screen in front of the participant (black font, white background, middle of the screen). The person then listened to the sentence again, while also looking at it on the screen. The sentence that required such visual feedback remained in the database of the training sentences and was presented again at the end of the session. The training continued until all 148 sentences were repeated correctly without visual feedback, and the information about the required number of repetitions was stored for each person. The feedback was determined to be visual as opposed to auditory. In the future the authors wish to apply the same, albeit adjusted, testing (and training) procedures in participants with hearing deficits. Selection of the speech stimuli for each stage of the experiment. At the beginning of the experiment, a MAT-LAB algorithm randomly selected two different lists of 10 HINT sentences for each of the 6 test conditions (3 before training and 3 after training) for each person individually. Another set of 148 sentences were used for the Training session. One list was saved for the Practice session. Ethics. The study was performed in accordance with all the relevant international and domestic guidelines and regulations, including the Declaration of Helsinki from 2013. Informed consent was obtained from each participant and they were compensated for participation. The experiment was approved by the Institutional Review Board of the School of Psychology of the Reichman University (formerly IDC), Herzliya. In the first step of the data analysis, we checked whether applying parametric tests to the data is valid. A Saphiro-Wilk test for normality revealed normal distribution of all participants' scores in 6 tests (2 sessions × 3 conditions), the Mauchly Test of Sphericity was non-significant indicating equal variances of the differences between the factor levels, and no outliers were identified according to the 3 IQR's rule. A repeated measures ANOVA was performed, with two within-subject factors: (a) Condition (Audio Only, Audio-Tactile matching, Audio-Tactile non-matching) and (b) Session (before and after Training) as well as one between-subject factor: (c) Group (Group 1 trained with the audio-tactile matching speech input vs Group 2 trained with the audio only speech input). Participants' scores (SRT) in speech-in-noise understanding tasks were the dependent variable. The ANOVA was followed by a series of planned paired t-tests to assess the improvement from session 1 to session 2 (i.e. before vs after training) in speech-in-noise understanding in the three speech conditions separately, to compare the amount of improvement between test conditions, and to compare the scores between conditions within sessions. Independent-sample t-tests were applied to compare the scores in the two groups with one another, to test the order effect of the ATm and ATnm test conditions, and to compare the mean SRT values at which both groups were trained. To compare the number of repetitions needed for the participant to complete the training (i.e. to repeat all 148 sentences correctly) we applied a non-parametric Mann-Whitney U test (Shapiro-Wilk test of normality, p = 0.001). Since the scores for all speech tests were normally distributed and the Deviation of Linearity was > 0.05, we applied r-Pearson correlation analysis to: (a) asses the relationship between the scores in subsequent speech tests in session 1 (before training) and the amount of improvement from session 1 to session 2 in each of them (in all participants, as all of them improved), (b) the amount of benefit of adding matching vibrations as compared to the scores in the audio only condition (only in participants that had better SRT scores in the audio-tactile condition, i.e. 28 people before training, and 32 people after). www.nature.com/scientificreports/ Furthermore, we applied a correlation analysis to assess possible relationships between outcomes of the speech tests and several measures of the English language background of the participants. We tested whether the following factors might be related to some of the variability in participants' performance in the speech tests: years of studying English and the average exposure to/communication in English everyday (mean of both at work/ university and outside). Since the distribution of some variables was not normal (Shapiro-Wilk test, p < 0.05), we applied the non-parametric Spearman Rho approach. Furthermore, independent-sample t-tests were applied to compare SRTs in subsequent test conditions between participants that started learning to speak English before age 7 (early learners; N = 17) and after 7 (late learners; N = 17) (age 7 years was the median), as well as between participants that self-reported their English language abilities as ≤ 4.17 (the median, on a scale 1-5, N = 20), and those reported their skills as being above 4.17 (N = 20) . SPSS (IBM Statistics 20) software was used to perform all the statistical analyses. GPower 3.1 software was applied for post-hoc assessment of the effect size (Cohen's d for t-tests and Cohen's f for F-tests) and power for each test. Due to the novelty of the study, there was no existing data to refer to in order to estimate the minimum sample size or the expected effect size a priori. In our previous study, though 31 we used the same set-up but only two study conditions (audio only and audio-tactile matching) and showed a significant difference between the scores for the two conditions with a sample size of 12. Descriptive statistics. We show in Table 2 Within-group effects: improvement (from session 1 to session 2) in SRT in each condition. To assess the amount of improvement after training, we first combined the scores of the two groups together (N = 40). We interpret p-values as significant when they were below the Bonferroni-corrected alpha value of alpha = 0.05/3 = 0.017. We showed that the participants significantly improved from Session 1 to Session 2 in all three conditions : in the Audio Only (A) condition, from mean 22.96 ± 10 dB to mean 6.47 ± 6.9 dB [t(39) = 11.72, p < 0.001, effect size = (Fig. 3) . The effect size of the improvement in the audio-tactile non-matching test condition was larger in Group 2 than in Group 1 (1.182 vs 0.594, respectively; although the degree of improvement was not statistically significantly different in the direct comparison between groups, t(38) = − 2.04, p = 0.048, Bonferroni-corrected alpha = 0.017). Between-group effects. When mean scores obtained by the two study groups were compared with one another in two sessions and in each test condition separately (Group 1 vs Group 2, independent t-tests), we found no statistically significant differences (see Supplementary Materials, Tables 1-2) . Training. Participants in Group 1 that trained with multisensory audio-tactile speech inputs needed on average 359.8 ± 132.1 repetitions of the sentences to accurately repeat all 148 of them (at a mean SRT of 14.7 ± 8.7 dB). Participants in Group 2 that trained with unisensory auditory speech inputs needed on average 351.6 ± 80 repetitions (at a mean SRT of 23.9 ± 11.8 dB). Mean SRT values at which the groups were trained were statistically significantly different between the groups (t = -3.2, p = 0.003). The required number of sentence repetitions in both study groups was not statistically significantly different (Mann-Whitney U = 184, p = 0.665). Correlation analyses. We found statistically significant correlations between participants' scores in subsequent speech tests and the amount of the corresponding improvement in each of them (Fig. 5) . The found statistical values were the following: www.nature.com/scientificreports/ p = 0.047). As the data shows and it can be seen in Fig. 5 , the R-Pearson correlation was found significant for all speech tests, but was least significant for the ATnm condition. In addition, we found that scores in the auditory only speech test positively correlated with the amount of improvement yielded by adding matching tactile vibrations (ATm1-A1) (R = 0.57, p = 0.002), but only before training. The result indicates that the multisensory benefit was most profound when the unisensory performance was poorest. After training, the relationship was not statistically significant (p < 0.05). Additional results using English language background information. With respect to the additional background information that we collected about the participants, we showed that participants who started learning to speak English at age < 7 had lower SRT values (better performance) by mean 2-6 dB in three speech tests before training than those that started learning after age 7 but the difference in scores was not statistically significant at Bonferroni-corrected alpha value of 0.05/3 = 0.017. At the same time, however, years of studying English were found to correlate with the SRT scores in the Audio only test (rho = − 0.27, p = 0.021) and the Audio-Tactile nonmatching test (rho = − 0.52, p = 0.001) before training, but not with the ATm speech test scores (rho = − 0.197, p = 0.22) (N = 40). This result indicates that more years of studying were related to lower (better) SRT values. In addition, higher average exposure (more frequent communication) to English was found to correlate with lower (better) SRT scores in the Audio-tactile nonmatching speech test before training (rho = − 0.362, p = 0.022). We also found an effect of self-rated English abilities, in that the participants who rated their skills as higher (above the median 4.17 on scale 1-5) as opposed to lower had consistently lower (better) SRTs in the speech tests. The effect was, however, only statistically significant for the Audio only test condition [t(38) = 2.53, p = 0.016, effect size = 0.8, power = 0.8; Bonferroni-corrected alpha value 0.017). More detailed results of these analyses are presented in Supplementary Materials (Table 3-5 ). Summary of the results. In the current experiment we replicated in a larger group of 40 participants our previous proof-of-concept study where we also showed enhanced speech-in-noise understanding (by mean 4-6 dB) when auditory speech signals were complemented with matching low-frequency tactile vibrations on fingertips 31 . As an addition to the previous study where no training was applied, we also used here two training types to test whether speech comprehension in noise can improve further. We found profound and comparable degree of improvement in performance, both after unisensory auditory training and after multisensory audiotactile training. The effect generalized to novel sentences and both unisensory and multisensory test conditions. In addition, the amount of the improvement shown in both audio only and audio-tactile matching test conditions was similar and exceeded 10 dB (mean 14-16 dB) in SNR/SRT. Such a decrease in the speech in noise reception threshold, is profound, as a 10 dB difference represents doubling of the perceived loudness 62 . Furthermore, participants trained with multisensory inputs (group 1) that were presented with sentences at a lower SNR (harder) than the other group needed a similar number of sentence repetitions to complete the training. This might be an indication that adding vibrotactile inputs can make the learning process easier, although further studies are necessary. The participants were furthermore tested on understanding sentences when the vibrations on the fingertips corresponded to a different sentence than the one presented as audio (i.e., they were non-congruent), both before and after training. For this test condition before training, we found a similar degree of benefit over audio only as when matching tactile inputs were used, and lower scores than in the audio only test condition following both types of training. This outcome, as well as the reported improvement in all testing conditions shows that the applied training (both uni-and multisensory) possibly removes some level of difficulty of sound perception per se, and hence the participants might be able after training to use the speech input delivered via vibrotactile stimulation more properly. We discuss below a number of theoretical aspects of the reported results, as well the potential implications of our study for basic science and rehabilitation. There have been numerous works showing that understanding speech in suboptimal acoustic conditions, such as e.g., speech in noise, noise-vocoded speech, time-compressed speech, can be trained. At the same time, however, the reported transfer of the training effects to novel speech inputs or contexts has been found to be limited [63] [64] [65] [66] . In that respect, our findings are novel, as we show not only significant benefits for speech understanding (> 10 dB in SRT) but also generalization of both training types to all three testing conditions (audio only, audio-tactile matching, audio-tactile nonmatching). We therefore report a transfer of improvement from a multisensory to a unisensory context, as well as in the opposite direction. Each time the effect was shown for completely novel sentences. A similar idea of multisensory training boosting unisensory auditory and visual speech perception, was shown by Bernstein and colleagues 20 and by Eberhard and colleagues 25 , respectively (although the applied language tasks were more basic than repeating whole sentences). We suggest that this robust and rapid improvement can have a number of practical applications, including in sensory rehabilitation, which we discuss further in text. We showed that both training types, the unisensory auditory training and the multisensory audio-tactile training, provided similar level of improvement in terms of the SNR change. This is probably due to the fact that the auditory input was present in both of them and thus practiced to a similar extent. Indeed, rapid perceptual learning and adaptation have been shown through repeated exposure for various acoustic contexts and distortions of the auditory signal, including natural speech presented in background noise, as well synthetically manipulated vocoded/ time-compressed speech 2, 3, 55, 63, 66 . This also explains why we saw some improvement in speech understanding in the control test condition, i.e., when the auditory sentences were paired with vibro-tactile inputs corresponding to a different sentence than the one presented through audition (ATnm). The degree of improvement was, nevertheless, far less robust in that test condition, as compared to the trained ATm and A conditions (approx. www.nature.com/scientificreports/ 6 dB vs 14-16 dB in SRT). Notably, the effect size of the improvement in the non-congruent audio-tactile condition was also smaller in the group trained with the matching audio-tactile inputs. This, as well as the fact that this group showed much more significant benefit of adding congruent vibrations to the auditory speech input after training, points to the specific effect of the applied training type. At the same time, however, adding tactile inputs might have facilitated the learning process, as the same degree of improvement (by mean > 10 dB) was achieved by Group 1, as compared to Group 2 (trained with audio inputs only), at harder SNR values. This finding is in line with some existing studies suggesting that learning and memory of sensory/cognitive experiences is more efficient when the trained inputs are multisensory, such as in patients after stroke 19 or in hemianopia (i.e., with loss of vision in only one part of the visual field and/or one eye 20 ]. In addition, we showed, using correlation analysis, that the improvement after training was reversely proportional to the initial test outcomes (as was expected and often reported in literature). It remains to be studied, whether a longer training session or training without feedback but with a fixed number of sentence presentations would be more appropriate to examine the benefit of one training approach over the other. Multisensory enhancement and audio-tactile speech input. We show in our study that 70% participants before and 80% participants after both types of training achieved best scores in the test condition that combined an auditory input with a matching tactile input. We believe that this finding might exemplify the inverse effectiveness rule of multisensory integration which predicts that multisensory enhancement, i.e., the benefit of adding information through an additional sensory channel, is especially profound for low signal-to-noise conditions (but see the possible role of order in the Limitations of the study paragraph) 52 . To further support this claim, we also showed, using correlation analysis, that the benefit for speech perception (SRT values) of adding matching tactile vibrations on fingertips to the degraded auditory signal increased before training, the poorer the person performed in the audio only test condition. This effect was not maintained after training, when auditory speech recognition already much improved. Indeed, our experimental procedure was specifically designed to benefit from the inverse effectiveness principle 5, 67 . In our study the auditory speech signal was new to the study participants, degraded (noise-vocoded), presented against background noise and in their non-native language. All these manipulations lead to a low signal to noise context, and deemed the auditory input less reliable, thus increasing the chance that a reliable tactile input will improve performance. To deliver tactile inputs, we developed our own audio-to-touch SSD. In the literature it has been suggested that SSDs can advance the benefits of providing a multisensory learning environment, since they convey input from one modality via another, in a way that is specifically tailored to the neuronal computations that are characteristic of the original sensory modality [41] [42] [43] [44] [45] [46] [47] . The delivered tactile inputs were complementary to the auditory speech. They also maintained features typical of the auditory modality, in that tactile vibrations are also a periodic signal that can fluctuate in frequency (and intensity). At the same time, the applied frequency range of the inputs was detectable by the tactile Pacinian cells that are most densely represented on the fingertips (as compared to other body parts) and most sensitive for encoding frequencies in the range of 150-300 Hz (and up to 700-1000 Hz) 68 . Specifically, the tactile vibration that was provided on fingertips of our participants was the low-frequency part of the speech signal, including the extracted fundamental frequency. The assumption that this specific input might help with speech perception was based on findings in healthy individuals (and hearing impaired, as discussed further in the text) that have been shown to benefit in their speech-in-noise understanding from addition of low-frequency sounds, which carry pitch information and thus help segregate auditory streams, including discriminating between speakers 29, 32 . We believe that the specific combination of audition and touch, the two senses that are indeed quite similar as they both encode vibrations through mechanoreceptors, made this multisensory context in our study especially intuitive. This might have contributed to the best of scores in speech-in-noise understanding in the test combining both congruent inputs, after both types of training, as well facilitate the learning process. Notably, the reported rapid improvement is in contrast to other SSD solutions that were based on more complex algorithms (e.g. translating visual images to sounds changing in pitch and timbre) and required hours of training to yield benefits [47] [48] [49] . To the best our knowledge, there have only been several research works thus far that have studied improvement in speech understanding by adding speech signals through touch, in normal hearing subjects with training 29 and in patients with hearing loss without any training 30, 69 . In Fletcher's work 8 participants showed after unisensory auditory training a mean improvement of 10% in understanding of CI-simulated sentences in noise when the participants also received concurrent low-frequency tactile stimulation on the fingertips. Before training the difference was at 5% and was not statistically significant. The authors tested speech comprehension at fixed SRTs, which were nevertheless individually established using an adaptive procedure 61 . At the same time, however, the participants were trained during 3 days at arbitrarily established harder SRT values, whereas we used the same individual SRT values during the whole training session (established separately for the auditory only and the audio-tactile training session). Due to these methodological differences, we cannot directly compare our findings with those reported by 29 . Nevertheless, we would like to note that the authors failed to report a significant benefit of adding tactile vibrations before training, as opposed to what we showed for our set-up in our previous and current work. In addition, the authors reported that speech in noise understanding with added touch improved by 10% due to training (61% to 71% of recognized keywords) but at the same time did not discuss this finding at all. Meanwhile, Huang and colleagues used a similar set-up to study speech in noise understanding in a group of 10 users of cochlear implants. The authors reported a 2.2 dB improvement in sentence understanding when participants were provided with additional low-frequency speech inputs, including f0, on their fingertips. The 2.2 dB improvement is less profound than the 4-6 dB multisensory improvement reported in our previous and current work. The underlying reason might be that the patients did not undergo any training, which might be www.nature.com/scientificreports/ specifically needed in the patient population due to the high cognitive demand required for speech in noise understanding 5, 10, 30 . While both 29 and 30 applied an experimental approach quite similar to ours, Perotta and colleagues used a wristband with linear actuators that delivered vibrations at a constant frequency and showed that (N = 18) hard-of-hearing patients can learn to discriminate word pairs based on patterns of vibrations. All these studies show that there is indeed a potential in using specifically prepared tactile information to boost speech understanding. At the same time, our current study is novel in that we collected data in a significantly larger group of healthy individuals (N = 40). In addition, we designed a control unisensory auditory training condition to estimate the effect of repeated exposure to the auditory input per se. We also added a control multisensory condition, with tactile speech frequencies that do not match the presented auditory sentence, to further investigate the role of touch. Furthermore, the participants of our study were non-native English speakers, the implications of which we discuss in subsequent paragraphs. We can only speculate that the differences in the outcomes in our study and the ones by 29 and 30 were also related to the fact that these authors tested native speakers of English. The revised plasticity theory. The level of multisensory benefit that we report in our study, both before and after training (4-6 dB) is comparable or higher to that reported when auditory speech in noise is complemented with cues from lip/speech reading [70] [71] [72] [73] . Since we have not tested audio-visual speech understanding in the current experiment we cannot, however, compare the outcomes of the two multisensory speech contexts directly. This idea is nonetheless worth further investigation, as synchronous audio-visual speech information is what we as humans are exposed to from the very early years of development and throughout our lifetimes 9 , as opposed to the audio-tactile speech input that is an utterly novel experience, at least for the tested healthy individuals (we talk about the specific case of the visually impaired further in text). We therefore argue that through a well-designed intervention one can establish in adulthood a new coupling between a given computation and an atypical sensory modality that has never been used for encoding that type of information before. We also show that this coupling can be improved through training, as all participants in the current experiment significantly improved in that test condition. These findings might provide further support for our new conceptualization of critical/sensitive periods in development, as presented in our recent review paper 22 . We suggest that brain plasticity, which indeed spontaneously decreases with age, can be reignited across the lifespan, even with no exposure to certain unisensory or multisensory experiences during childhood. Several studies from our lab and other research groups, mainly involving patients with congenital blindness, as well as the current study, point in that direction (e.g. by showing that congenitally blind participants can use hierarchically organized brain visual networks for recognition of faces, body shapes, letters, etc. with the stimuli conveyed through audio-visual SSDs) 21, 74, 75 . A similar line of research (although not with an SSD and for another pair of senses) was also reported by Ernst and colleagues where participants learned to integrate signals from vision and touch (luminance and stiffness) and after training showed increased discrimination thresholds (poorer performance) for non-congruent vs congruent pairs of stimuli 76 . The control tactile condition. In our experiment we introduced a control audio-tactile condition with vibrations not corresponding to the auditory sentence, to test how it would affect speech-in noise understanding. Adding this control condition is novel and was not studied thus far in works dedicated to tactile speech processing 29, 30, 69 . In the literature, it has often been shown that while a congruent input from two sensory modalities can improve performance through cross-modal interactions 23,24 , non-matching or distracting information in one sensory modality can impair performance 5, 70, [77] [78] [79] . Indeed, we show here that after training both groups of participants had poorest scores in the audio-tactile non-matching test condition and for both groups the improvement in this speech test was least significant. At the same time, however, the scores before training were almost the same for both conditions combining an auditory and a tactile input, i.e. for both congruent and non-congruent pairs. The revealed mean SRT values for both of them were also significantly better than those reported for the audio only test condition. This indicates a possible non-specific multisensory effect before training, i.e., during the period of familiarization with the audio-tactile study set-up. The non-specific tactile input might possibly be helping the participants to keep their attention on the task. Although the vibrations in the control condition were not congruent with the speech signal, they still resembled the target sentence more than the background noise and thus helped the participants focus on the target input. The data suggests that within a short time participants learned to ignore the non-matching vibration, which led to the poorest scores in this test condition after training. Alternatively, and as already suggested above, participation in training may have removed some level of difficulty of sound perception, which made it easier for the participants to properly use the speech information present in vibrotactile stimulation. Therefore, we believe that the results of the post-training test session might actually be more representative of the benefit of adding speech-related information through touch for speech perception [see Ernst and colleagues for a similar effect of training congruent vs non-congruent visuo-tactile pairs of stimuli 76 ]. In addition, the fact that one group trained with congruent tactile inputs seems to have resulted in their lesser improvement in the audio-tactile nonmatching condition as well as poorer audio-tactile nonmatching scores after training (as compared to the group trained with unisensory auditory inputs). The reason might be related to the fact that the ATnm test condition might have actually been the hardest in terms of the required cognitive resources, including selective attention, and inhibition from distraction 79 . In order to elucidate the effects of the multisensory congruency effect further, research involving controlled selective attention of the participants is needed. One can speculate that a training session of focusing attention on the inputs from a single sensory modality might both reduce the distracting effects of the nonmatching tactile input (when focused on the auditory aspect) and improve the benefit of adding matching vibrations further (when focused on the matching tactile input). www.nature.com/scientificreports/ Non-native speakers of English. The reason why we focused on non-native English speakers in our study was to further benefit from the inverse effectiveness rule of multisensory integration requiring low SNR between senses. At the same time, we made sure that the participants were fluent in English and felt comfortable with the experimental setting. Non-native listeners have been shown to perform much poorer in speech-innoise tasks than native English speakers. The reduced performance has been attributed to a number of factors, such as language proficiency, degree of exposure to the foreign language and age of language acquisition 10, 27, [55] [56] [57] . In the current experiment we used the HINT sentence database consisting of sentences with semantic content which are to some extent predictable 60 . Therefore, we assumed (and actually witnessed during the study) that the participants would apply their high-level knowledge to improve perception and predict/guess the upcoming language information. We performed several additional analyses to test, whether the English language background of the participants would translate to their speech scores before training. Indeed, we showed that a longer time of studying English, more exposure to it in both professional and leisurely contexts, as well as better self-rated skills in English were related to better initial scores in speech comprehension through audition (A1). More years of studying and higher everyday exposure to English translated also to better scores in the audiotactile nonmatching test condition (ATnm1). As mentioned before, this effect might be related to the fact that the noncongruent multisensory task requires additional cognitive resources, which might have been trained in the foreign-language contexts throughout life. In addition, we found that the participants that started learning English at an earlier age (< 7 years of age) had better scores in all speech-in-noise understanding tasks before training, although this effect was not statistically significant. We therefore provide no strong evidence for the existence of "critical periods" in development for the second language acquisition 56 . This effect might possibly occur for language acquisition at ages below 3 (e.g. vs in adulthood), while only 4 of our participants started learning English that early in life. For non-native English speakers it has also been shown that in suboptimal speech contexts they might more readily attend to inputs from additional modalities, such as vision. This has been observed in contexts, such as the McGurk effect during which non-congruent lip-reading cues affect auditory perception, as well as when congruent gestures are present to support speech perception 10, 58 . It has been suggested that this higher reliance on visual cues might stem from the linguistic challenge that non-native listeners experience, but at the same time does not have to translate to improved performance in speech understanding 27 . To the best of our knowledge no studies exist that investigated audio-tactile speech contexts, where the same testing and training set-up was applied in native and non-native English speakers. We nevertheless speculate that native English speakers will also benefit from our solution, but due to the better language skills might need to be exposed to poorer SNRs for the multisensory benefit to be detected. Further research on this is required. Applications of our set-up and audio-tactile SSD for sensory rehabilitation. Thus far, the results of our previous and current studies show that our set-up can assist healthy individuals in improving their understanding of distorted speech in background noise. This already indicates the possible general application of our solution in learning foreign languages. In addition, our technology and the tactile feedback can also potentially improve understanding speech over the phone, as well as appreciation of music. In the current experiment the trained speech signal was distorted (noise-vocoded) in order to recreate the experience of speech perception through a cochlear implant. This was done, as we are planning to test and train audio(-tactile) speech perception in patients with hearing deficits in our next study. We believe that our set-up holds promise for rehabilitation in this population as these patients specifically struggle with understanding speech in noise, despite their good performance in quiet environments [15] [16] [17] . The underlying reason for this disadvantage is that the degraded auditory input that the patients are exposed to is deprived of the temporal fine structure information (the rapid oscillations close to the fundamental frequency, f0/pitch) 32 which is the basic cue for speech stream segregation and discrimination among speakers 80 . In sensorineural hearing loss this information is impaired or lacking due to the damage to the inner ear, whereas in CI-users it is due to the limitations of the algorithms applied for speech coding 81, 82 . Some evidence of the benefit of adding low-frequency speech cues for speech understanding was shown for patients with partial deafness (high-frequency sensorineural hearing loss) who use a partially inserted CI electrode array combined with low-frequency acoustic signal delivered naturally or via a hearing aid in the same ear. These patients consistently show superior performance in speech-in-noise understanding, when compared to profoundly deaf users of CIs 33, 80, 83, 84 . In addition, Huang and collegues 30 already showed improved speech-in-noise understanding in a group of CI users when sentences were accompanied with low-frequency vibrations corresponding to the extracted low frequency sounds from the speech input, with no prior training. Nevertheless, we believe that in the case of the hearing impaired, for whom speech-in-noise understanding requires more cognitive effort than in healthy individuals, training might actually be required to yield visible benefits. Indeed, users of cochlear implants have been found to improve following extensive audio-visual training sessions combining the restored auditory input with speech-reading or sign language 1, 6, 65, 70, 73, 86, 88 . As we show in the current study, speech understanding can successfully be trained (both through unisensory and multisensory inputs) using our set-up. In addition, with future hard-of-hearing candidates for cochlear implantation, we believe that both unisensory auditory (or maybe also unisensory tactile, though it has not been tested here) and multisensory audio-tactile training can be applied, with the aim of "preparing" the auditory cortex for future processing of the auditory input. We speculate that this can be achieved, based on a number of works from our lab which show that specialization of the sensory regions in the brain, such as the (classically termed as) visual or the auditory cortex, can emerge also following a specifically designed training regimen with inputs coming from another modality, as long as they preserve specific computational features (Task-Selective and Sensory-Independent (TSSI) brain organization) 22 www.nature.com/scientificreports/ Another interesting line of study by the Petrini group shows yet another possible implementation of our audio-tactile SSD set up. The research of the group shows that audio-haptic integration, and namely discrimination of object sizes by touching and/or listening to them is consistently less efficient in individuals with late onset visual impairments, as compared to the early-blind and the healthy population 59, 77 . The authors explain that since touch and not vision is the dominant modality for performance in this specific task, early blind individuals are not affected. Their results also suggest that enhancement of perceptual functioning in remaining senses (i.e. in the visually impaired, audition and touch) is practice-dependent and thus related to the consistency of the experience. We therefore suggest that our set-up could be applied to train audio-tactile integration abilities in these individuals. Especially since audition and touch and their successful integration are what the blind population relies on (this would obviously require adjustments of the study paradigm, including e.g., using an auditory instead of visual feedback during the training session). It would be also interesting to see how the fact that part of this population uses Braille reading, which requires matching certain tactile inputs with language units, would be reflected in training outcomes using our audio-tactile SSD set up. We believe that development of assistive communication devices, both with and without tactile cues is especially needed in the time of the COVID19 pandemic which imposes numerous restrictions on live communication, including the limited access to visual speech cues from lip reading. The robust outcomes, that we have obtained after a relatively short and easy training session of < 1 h can make our set-up a valuable and effective tool for rehabilitative, professional, and educational settings. Although our set-up is already relatively small in size, as opposed to the more cumbersome solutions using tactile inputs that are available on the market 48,90 , our lab already started developing new minimal tactile devices that can provide vibrotactile stimulation also on other body parts, beyond the fingertips. Our aim is to design a set-up that will be wearable and therefore will assist with speech-in-noise comprehension (and sound source localization) in real-life scenarios. In addition, our current SSD is compatible with a 3 T MRI scanner. We have already collected functional magnetic resonance (fMRI) data in a group of participants performing the same tasks of unisensory and multisensory speech comprehension. The results can help uncover the brain mechanisms of speech-related audio-tactile binding and improvement, and may provide information on inter-subject variability in relation to the benefits of multisensory learning. This latter aspect, in turn, could further direct rehabilitation and training programs. To the best of our knowledge this would be the first attempt at elucidating neural correlates of understanding speech presented as a combined auditory and vibrotactile input. Multisensory integration in cochlear implant recipients Cued speech enhances speech-in-noise perception Visual enhancement of relevant speech in a "cocktail party Prediction and constraint in audiovisual speech perception The principle of inverse effectiveness in audiovisual speech perception Cued speech for enhancing speech perception and first language development of children with cochlear implants Visual speech perception in children with language learning impairments Psychobiological responses reveal audiovisual noise differentially challenges speech recognition Development of the mechanisms underlying audiovisual speech perception benefit Degree of language experience modulates visual attention to visible speech and iconic gestures during clear and degraded speech comprehension Cognition in older adults with severe to profound sensorineural hearing loss compared to peers with normal hearing for age Dementia prevention, intervention, and care Association of age-related hearing loss with cognitive function, cognitive impairment, and dementia: A systematic review and meta-analysis The dynamic relationship between hearing loss, quality of life, socioeconomic position and depression and the impact of hearing aids: Answers from the English Longitudinal Study of Ageing (ELSA) Effects of senescent changes in audition and cognition on spoken language comprehension Prevalence of hearing loss and differences by demographic characteristics among US adults: Data from the National Health and Nutrition Examination Survey Noise-induced hearing loss: A modern epidemic? Multisensory stimulation to improve low-and higher-level sensory deficits after stroke: A systematic review Improvement of visual search after audiovisual exploration training in hemianopic patients Multisensory integration in hemianopia and unilateral spatial neglect: Evidence from the sound induced flash illusion Origins of task-specific sensory-independent organization in the visual and auditory brain: Neuroscience evidence, open questions and clinical implications Task-selectivity in the sensory deprived brain and sensory substitution approaches for clinical practice Benefits of multisensory learning The Neural Bases of Multisensory Processes Auditory perceptual learning for speech perception can be enhanced by audiovisual training Multisensory training can promote or impede visual perceptual learning of speech stimuli: Visual-tactile versus visual-auditory training Nonnative audiovisual speech perception in noise: Dissociable effects of the speaker and listener Implications of cross-modal and intra-modal plasticity for the education and rehabilitation of deaf children and adults Vibro-tactile enhancement of speech intelligibility in multi-talker noise for simulated cochlear implant listening Electro-tactile stimulation enhances cochlear implant speech recognition in noise Immediate improvement of speech-in-noise perception through multisensory stimulation via an auditory to tactile sensory substitution Unintelligible low-frequency sound enhances simulated cochlear-implant speech recognition in noise A new method of partial deafness treatment Vibration-induced auditory-cortex activation in a congenitally deaf adult Vibrotactile activation of the auditory cortices in deaf versus hearing adults Compensatory plasticity in the deaf brain: effects on perception of music Multisensory contributions to the perception of vibrotactile events Haptics in music: The effects of vibrotactile stimulus in low frequency auditory difference detection tasks Hearing, feeling or seeing a beat recruits a supramodal network in the auditory dorsal stream Evidence of vibrotactile input to human auditory cortex EyeMusic: Introducing a "visual" colorful experience for the blind using auditory sensory substitution An experimental system for auditory image representations Vision substitution by tactile image projection Tactile sensory substitution studies Visual' acuity of the congenitally blind using visual-to-auditory sensory substitution Large-scale brain plasticity following blindness and the use of sensory substitution devices. in Multisensory Object Perception in the Primate Brain The effect of expanded sensory range via the EyeCane sensory substitution device on the characteristics of visionless virtual navigation Cross-modal brain plasticity in congenital blindness: lessons from the tongue display unit Clinical application of sensory substitution for balance control Principles of multisensory. behavior Visual, auditory, and somatosensory convergence on cells in superior colliculus results in multisensory integration The law of inverse effectiveness in neurons and behaviour: Multisensory integration versus normal variability Spread of Excitation (SoE): A non-invasive assessment of cochlear implant electrode placement Error patterns of native and non-native listeners' perception of speech in noise Speech perception in noise by monolingual, bilingual and trilingual listeners Non-native speech perception in adverse conditions: A review Hearing lips in a second language: Visual articulatory information enables the perception of second language sounds Language experience changes audiovisual perception Late-but not early-onset blindness impairs the development of audio-haptic multisensory integration Development of the hearing in noise test for the measurement of speech reception thresholds in quiet and in noise Adaptive testing in audiology On the psychophysical law Improving older adults' understanding of challenging speech: Auditory training, rapid adaptation and perceptual learning Audiomotor perceptual training enhances speech intelligibility in background noise Training of speech perception in noise in pre-lingual hearing impaired adults with cochlear implants compared with normal hearing adults How top-down processing enhances comprehension of noise-vocoded speech: Predictions about meaning are more important than predictions about form Do you see what I am saying? Exploring visual enhancement of speech comprehension in noisy environments The roles and functions of cutaneous mechanoreceptors Deciphering sounds through patterns of vibration on the skin Audio-visual speech inteligibility benefits with bilateral cochlear implants when talker location varies Visual speech benefit in clear and degraded speech depends on the auditory intelligibility of the talker and the number of background talkers Quantifying the contribution of vision to speech perception in noise Head orientation benefit to speech intelligibility in noise for cochlear implant users and in realistic listening conditions Efficiency of sensory substitution devices alone and in combination with self-motion for spatial navigation in sighted and visually impaired Navigation with a sensory substitution device in congenitally blind individuals Learning to integrate arbitrary signals from vision and touch Modality-specific selective attention attenuates multisensory integration Do congruent lip movements facilitate speech processing in a dynamic audiovisual multi-talker scenario? An ERP study with older and younger adults Fundamental frequency is critical to speech perception in noise in combined acoustic and electric hearing The role of temporal fine structure processing in pitch perception, masking, and speech perception for normal-hearing and hearing-impaired people What is temporal fine structure: Why is it important? Results of partial deafness cochlear implantation using various electrode designs Electric-acoustic stimulation of the auditory system: A review of the first decade Shape conveyed by visual-to-auditory sensory substitution activates the lateral occipital complex When vision is not an option: Children's integration of auditory and haptic information is suboptimal Perceptual learning and auditory training in cochlear implant recipients Task selectivity as a comprehensive principle for brain organization Neural indiced of listening effort in noisy environments Navigation using sensory substitution in real and virtual mazes Using space and time to encode vibrotactile information: toward an estimate of the skin's achievable throughput In the testing session the auditory only speech test (A) always preceded the audio-tactile test conditions (ATm, ATmn). We therefore cannot exclude some effect of order, with respect to the obtained benefits of the complementary tactile speech information. We nevertheless believe that if there was such an effect, it was minimal, especially after exposure to > 200 sentences before the post-training test session. We also found no order effect for the two multisensory audio-tactile test conditions, neither before nor after training (as we reported in the "Results" section). In addition, the current study only shows immediate outcomes of the applied training and thus further studies are needed to assess whether long-term training protocols can further improve and/or retain the effects of learning, and which components of the training best enable this goal. The long-term effects are especially crucial for efficient sensory rehabilitation. K.C. performed literature review, designed the study, collected the data, analysed the results, prepared the manuscript. T.W. designed the study, developed methods for data collection and presentation, analysed the results, prepared figures. A.L. designed the study, reviewed the manuscript. M.M. collected the data, analysed the results, prepared the manuscript. H.S. designed the study, reviewed the manuscript. A.A. designed the study, prepared the manuscript. The authors declare no competing interests. The online version contains supplementary material available at https:// doi. org/ 10. 1038/ s41598-022-06855-8.Correspondence and requests for materials should be addressed to K.C.Reprints and permissions information is available at www.nature.com/reprints.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.