key: cord-0961661-zjymmuuy authors: Li, Jun; Long, Yin; Yang, Fan; Wang, Xudong title: Respiration‐driven triboelectric nanogenerators for biomedical applications date: 2020-08-09 journal: EcoMat DOI: 10.1002/eom2.12045 sha: c59e5b1ed70736212fa26fba752e8500f4feb665 doc_id: 961661 cord_uid: zjymmuuy As a fundamental and ubiquitous body motion, respiration offers a large amount of biomechanical energy with an average power up to the Watt level through movements of multiple muscles. The energy from respiration featured with excellent stability, accessibility and continuality inspires the design and engineering of biomechanical energy harvesting devices, such as triboelectric nanogenerators (TENGs), to realize human‐powered electronics. This review article is thus dedicated to the emerging respiration‐driven TENG technology, covering fundamentals, applications, and perspectives. Specifically, the human breathing mechanics are first introduced serving as the base for the developments of TENG devices with different configurations. Biomedical applications including electrical energy generation, healthcare monitoring, air filtration, gas sensing, electrostimulation, and powering implantable medical devices are then analyzed focusing on the design‐application relationships. At last, current developments are summarized and critical challenges for driving these intriguing developments toward practical applications are discussed together with promising solutions. [Image: see text] Respiration is a fundamental and ubiquitous body movement that serves as a critical metabolic process of body exchanging oxygen and carbon dioxide. Besides, respiration is also a process of outputting work by converting chemical energy into mechanical energy, through the motion of intercostal muscles, lung muscles, and diaphragm. An average adult breathes at a normal rate of 12 to 16 times per minutes could provide a maximal power of up to the Watt level, which is a significant biomechanical energy source in human body and is adequate to support many small electronics. [1] [2] [3] [4] If harvested effectively and appropriately, this energy source may allow us to bypass the bulky batteries in those electronics. More importantly, respiration is primarily an involuntary movement 5,6 (another typical one is heart beating) that consistently output biomechanical energy regardless of time and body status. It thus can be considered as a continuous and stable body energy source that other voluntary body movements (eg, muscle stretches from fingers, arms, legs, and feet 7, 8 ) cannot compete with. Compared to heart beating, the motion from respiration is more accessible and has a higher energy density. Therefore, respiration could be the most appropriate biomechanical energy source for continuously powering wearable and implantable electronic devices to achieve 100% self-powered battery-free operation. Among a number of mechanical energy harvesting principles, triboelectric nanogenerator (TENG) stands out with its simple configuration, light weight, large power density, high energy conversion efficiency, and durability. [9] [10] [11] [12] [13] [14] [15] The last decade has witnessed big advancements of TENG from a basic concept 16 to a well-established technology holding promises in a wide range of applications. [17] [18] [19] [20] [21] [22] [23] [24] The broad selection of biocompatible materials, particularly those with a high flexibility and stretchability, for TENG designs is an essential advantage for biomedical applications. For instance, TENGs has been applied as active sensors for real-time healthcare monitoring through deciphering electrical signals into physiological information (eg, respiration, 25, 26 heartbeats, 27, 28 and blood pressure 29 ). Implantable TENGs have been designed to generate μW-level electricity from regular body movements, which was sufficient to power implantable medical devices (IMDs) such as pacemakers. 30, 31 Intriguing interactions between TENG and cell/tissue/organ activities 32, 33 were also discovered enabling self-powered therapeutic stimulations. [34] [35] [36] [37] Being aware of the unique advantages of biomechanical energy from respiration, a number of TENGs prototypes were designed and demonstrated, based on which intriguing biomedical applications were implemented. Although comprehensive review articles were published reporting the progress of TENG, 9, 10, 13, 38, 39 there is no focused review dedicating to respiration-driven TENG technology. To fill this gap, this article provides an overview of respiration-driven TENG and its biomedical applications. The driving mechanics from respiration are first introduced serving as the base for designing TENG devices with different configurations. Applications including electrical energy generation, healthcare monitoring, air filtration, gas sensing, electrostimulation, and powering IMDs are then reviewed focusing on the design-application relationships. At last, critical challenges for driving these intriguing developments toward practical applications are discussed together with potential solutions. Breathing is a fundamental biological process that requires coordinated motions of different muscles with repeated constrictions and relaxations to realize the gas-exchange process ( Figure 1A) . Specifically, during inhalation, both the diaphragm and intercostal muscles between ribs contract leading to chest expansion, which increases the intrapulmonary volume of lung and decreases the intrapulmonary pressure down by 1 to 2 mm Hg, 40 forcing air in. In expiration, the relaxation of diaphragm and intercostal muscles decreases the intrapulmonary volume and increases pressure to 761 to 762 mm Hg, and thereby moves air out of lungs. In the case of heavy breathing, the movement of abdomen is also involved. The mechanical energy associated with respirationrelated body motions has been well studied previously. [41] [42] [43] To perform a respiration cycle, the body needs to overcome three major types of resisting forces, that is, elastic force of chest-lung system (P el ), air viscance and turbulence (P alv ) due to pressure gradient between the alveoli and the mouth, and non-elastic tissue deformation resistance (P def ) (deformation of tissue between lung surface and the alveoli) ( Figure 1B ). Results based on empirical studies showed that among the overall mechanical energy consumed in respiration, 63% is to overcome the elastic force, 29% is related to air resistance, and the remaining 8% is to deform tissues. To approximate the total biomechanical energy from respiration, first, the linear elastic force could be expressed as: where K is the elastance and V is the lung volume. Together, P alv and P def are estimated as following: where (dV/dt) is the lung volume changing velocity and K 1 and K 2 are the constants. Therefore, the total force required for a respiration is: Assuming that the velocity of volume change is a sine wave, which is close in a real scenario, the output mechanical work per respiration could be calculated as: where V T and f referring to the tidal volume and respiration frequency, respectively. Furthermore, expression of mechanical power could be deducted as According to Equation (5), given a reasonable respiration volume of 6 L at a frequency of 15/min, it can be estimated that respiration of an average adult in a resting status could generate a power around 80 mW. 41, 43 For an air intake of 30 L/min under normal activity, the power value could reach to approximately 1 W. 1 Impressively, heavy and rapid breath could even produce a mechanical power up to 44 W (at a frequency of 30/min and a maximal ventilation of 150 L/min that an individual could perform). 41 In general, there is a considerable power availability from respiration if one takes account of the energy consumption of common electronics. Specifically, the sensor nodes have an power consumption at the nW or μW level. [44] [45] [46] Most implantable medical devices require a power supply in the range of μW to mW. [47] [48] [49] Even some portable electronics such as smart phone only demands 1 W of power. 50 This comparison revealed the promises of using biomechanical energy from human respiration for powering most biomedical electronic devices. All TENGs operate through the coupling of contact electrification and electrostatic induction. 10, 11 Although TENG embodies a plethora of configurations and structures, there are four common operation modes in general, that is, vertical contact-separation (CS), lateral in-plane sliding, single-electrode and freestanding mode, which have been comprehensively reviewed in a number of articles. [9] [10] [11] 13, 51 Considering the specific motion patterns of respiration, to achieve high energy harvesting efficiency, most respiration-driven TENGs were built based on the first two modes, that is, CS and sliding modes. As generally known, the electricity in a CS mode TENG is generated by charge induction to balance the dynamic electrostatic field between triboelectric films that periodically separate and contact. The advantage of the CS mode is its high sensitivity to mechanical stimulus. However, the requirement of an air gap from separation raises engineering challenges for packaging and encapsulation. For a lateral sliding (LS) mode TENG, the electricity is generated by creating potential and electron flow between two electrodes through in-plane displacing two triboelectric films back and forth. This mode is usually associated with enhanced output power compared to the CS mode especially when implementing a micrograting design; yet it requires larger area for operation. Numerically, for a CS mode TENG, 52 the open-circuit voltage (V OC ) and short-circuit current (I SC ) can be expressed as: where l is the length, w is the width, σ is the charge density, d 0 = d 1 /ε 1 + d 2 / ε 2 , d 1 and d 2 are the thickness, ε 1 and ε 2 are dielectric constants of dielectric films 1 and 2, and velocity v(t) = dx/dt, respectively. Analogously, V 0 OC and I 0 SC in the sliding mode 53 can be expressed as a function of lateral displacement x(t) as: Based on these equations, one could find that both modes have V OC and I SC related to variables due to mechanical stimuli (displacement or velocity of displacement). This relationship explains why simple deciphering the electricity signals of TENG could obtain essential physiological information such as respiration rate (associated with v(t)) and respiration depth (associated with x(t)). As mentioned in previous section, the chest movement and air flow contribute to the majority of biomechanical energy from respiration at 63% and 29%, respectively. 41, 42 Therefore, two types of TENG devices have been designed in response to this two types of mechanical energy ( Figure 1C ). One type TENG is an aeroelastic vibration device activated by air flow during breathing. This device is capable of being integrated with face masks that usually contain a triboelectric beam with either a cantilever (one-side fixed) or a bridge (two-side fixed) configuration. It works based on the effect of aeroelastic flutter due to the coupling of aerodynamic force and elastic deformation. [54] [55] [56] [57] [58] [59] Specifically, when the energy of air flow exceeds the mechanical damping of the triboelectric beam, beam vibration could be sustained with a large amplitude that drives the beam to touch the package case, resulting in triboelectrification between the beam and the case. The amplitude of the triboelectric beam vibration under a respiratory airflow initially remains stable until the velocity of airflow exceeds a critical value. The critical flow speed at which destabilizing the aerodynamic effects is of interest for the design of the device. This speed U C could be simply estimated by balancing the bending forces (Eh 3 η/L 4 ) with the aerodynamic forces (ρ f U 2 η/L): where L is the length of beam, E is Young's modulus, ρ f is the air density, h is the beam thickness, and η is the tilting angle. 60 Apparently, the critical velocity is related to the stiffness, geometry of the beam, and air density. Once fluttering occurs, the flutter frequency is determined by the natural frequency of the beam that could be expressed as: where m is the mass per unit length, I is the moment of inertia of the beam, and λ i is a constant related to the modes of vibration. 61 This equation applies to both cantilever beam and end-fixed beam yet λ i is much different between them. The first three constants of cantilever beam are exemplified, with λ 1 = 4.73, λ 2 = 7.85 and λ 3 = 10.99. The flutter frequency should be equal to its lowest bending mode of natural frequency. Moreover, the complete motion of the beam subjected to respiratory airflow could be given based on the Euler-Bernoulli equation considering the thin film structure: where l is the width of beam and ΔP is the pressure difference on the two sides of beam due to airflow. 62, 63 However, developing an analytical solution to this equation is complicated since the pressure difference is not constant during the vibration. Overall, this type of device usually generates high-frequency electricity regardless of respiration rate as the frequency is determined by the natural frequency of triboelectric beam. Another type TENG device is motion triggered which is usually applied to the chest (thoracic respiration) or abdomen (abdominal respiration) to harvest energy from respiration. Specifically, the regular constriction and relaxation of muscle due to respiration deform the device and make periodic displacement, either vertically or laterally (CS and LS modes, respectively), to generate triboelectric output. As exemplified in Figure 1C , a LS-mode TENG belt is wrapped around the chest. When air is inhaled, the chest expands and stretches the belt to pull the dielectric films apart from each other. When exhales, the chest contracts and the belt relaxes driving the films back to their original places. In response to this type of motion, the electrical output usually synchronizes with the respiration pattern at a low frequency. Details of reported type I and type II devices were compiled and compared in Table 1 . F I G U R E 1 Mechanics of respiration. A, Schematics of muscle movement and air flow during inspiration (upper image) and expiration (bottom image). B, Typical pressure-volume loop (one respiratory cycle) during breathing. P el , P def , and P alv are represented by the abscissal distance from the axis of ordinates to the diagonal, from the diagonal to the dashed curve, and from the dashed curve to the loop, respectively. C, Schematics of two main types of respiration-driven TENG that harvest energy from respiration at different locations. TENG, triboelectric nanogenerator The triboelectrification effect could be found in almost all materials including polymers, ceramics, metals, and so on. Based on the affinity to electrons, triboelectric series have already been established to serve as guidelines for designing TENGs. 9, 74 Basically, a positively triboelectric material (low affinity to electrons) is usually paired with a negatively triboelectric material (high affinity to electrons) to enable the maximized output. However, regarding to harvesting biomechanical energy from human body, materials with tissue-compatible properties are more desired. For instance, metal thin film (such as gold, aluminum made by deposition) and low-modulus polymer film (such as polydimethylsiloxane [PDMS], Kapton, polytetrafluoroethylene [PTFE]) are usually exploited for building flexible/stretchable TENGs. 16, [75] [76] [77] In the consideration of wearability, TENGs consisting of textile/fabric by weaving triboelectric yarns are developed. [78] [79] [80] Those yarns have core-shell structure with commercial threads (core) and coatings (shell) possessing strong electrostatic effects. Another important material property is the biocompatibility, which must be taken account of when designing the implantable devices. 81, 82 TENGs will receive additional biocompatible encapsulations (mostly PDMS) to avoid inflammatory reaction if they operate inside body. There are several strategies to enhance the triboelectrification effect in terms of materials selection and engineering. The surface of materials could be modified by physical techniques (such as photolithography and plasma etching) to create nano/micro patterns, which would enhance the surface area and thus the device output. 83, 84 Chemical methods including fluorinated surface, ion injection, sequential infiltration synthesis and molecular-targeting functionalization could also alter the surface properties and enable high performance. 15, 85 In addition, compositing two or more pure materials such as embedding micro/nanomaterials into polymer matrix would effectively adjust the dielectric constant, and enhance the triboelectric performance of devices as well. 86, 87 In general, clear understanding of the respiration mechanics together with triboelectric principles lays the foundation for the design and engineering of TENG devices that could effectively convert respiration motions into continuous electricity for a variety of biomedical applications. The self-powering capability with other featured properties such as softness, flexibility, biosafety, and biocompatibility opens up many possibilities for TENGs in biomedical engineering. Hitherto, respiration-driven TENGs have been implemented in a wide range of biomedical applications as a unique and self-sustainable electrical power/signal source. The applications mainly cover six directions including electrical energy generation, healthcare monitoring, air filtration, gas sensing, electrostimulation, and powering IMDs, which will be discussed in this section. The basic function of TENG is to generate electrical energy from mechanical motions. Both types of respiration energy from air flow and chest/abdomen movement have been actively investigated for TENG designs for electricity generation. Aeroelastic vibration devices capable of harvesting respiration energy were developed by multiple investigators. Wang et al reported a device consisting of a triboelectric beam and acrylic frames. 64 The bottom and top side frames were covered with PTFE and Cu electrodes (Figure 2A ), a Kapton film covered by Cu electrodes on both sides was fixed between the acrylic frames. Finite element analysis (FEA) simulation revealed the relationship between airflow and the vibration of the soft beam. Six vibration modes and their corresponding natural frequencies were calculated, with the first-order and second-order modes corresponding to bending motion (372 Hz) and twisting motion (378 Hz) that determined the aeroelastic fluttering (twisting frequency higher than bending frequency) ( Figure 2B ). Under an airflow speed of 15 m/s, this device output a high V OC over 180 V at a frequency of 380 Hz ( Figure 2C ). A maximum power output was estimated to be 9 kW/m 3 ( Figure 2D ). Driven by human breathing, output voltage and current can be up to 30 V and 18 μA under a loading resistance of 2.3 MΩ, respectively, resulting in an output power of 0.75 mW. A capacitor of 10 μF could thus be charged from 0 to 1.8 V in only 0.33 second. In another similar work, Zheng et al demonstrated a cantilever structure with one fixed end. 65 This device used a Cu-covered acrylic film as the substrate and electrode-covered fluorinated ethylene propylene/polyvinylidene fluoride (PVDF) composite film as the cantilever beam ( Figure 2E ). Under an air flow speed of 5 to 18 m/s, the TENG produced a low-frequency (1 Hz) voltage at 100-V level with a maximum of 350 V at 18 m/s ( Figure 2F ). The significant frequency difference between this cantilever device and the above-mentioned bridge one is because of the different natural oscillation frequencies based on fixing types and beam materials. The output power of this TENG could be up to 4.74 mW, where an extra power of 184.32 μW was contributed by the piezoelectric PVDF material. Integrated with a face mask, this device could produce sufficient electricity (45 V and 2.2 μA) to light 31 green LEDs concurrently by harvesting energy from human breath. In a motion-triggered device for harvesting respiration energy, a CS mode TENG (nylon and PTFE dielectric films with Cu electrodes) was integrated with a belt through "Z-shaped" connectors to be applied to the waist. 68 During respiration, the decreased chest/abdomen circumference retracts connectors causing the full separation of polymer films, whereas expanded chest/abdomen during expiration stretches connectors to render dielectric pairs contact. This device on human volunteers produced a reasonable V OC of 7 V yet a low current around 0.1 μA ( Figure 2G ). The instantaneous power only reached a peak value of 0.23 μW ( Figure 2H ). Another similar belt reported by Vasandani et al involved a CS TENG with microstructures. It was able to charge a 1 μF capacitor to 1.261 V in 300 seconds when driven by respiration, corresponding to a power output at the nW level. 69 These power values were significantly lower than those from aeroelastic devices, which were attributed to the coordinated low-frequency motions between the TENG and the respiration rhythm (0.7 Hz). In general, current respiration-driven TENGs had a power output in the range of 0.1 μW to 1 mW. Although the chest movement contributes to the most mechanical energy, the motion-triggered devices exhibited significantly lower power output compared to the aeroelastic devices. Considering the large amount of available energy from respiration, both types of devices need to be optimized to largely improve their biomechanical energy utilization rate and energy conversion efficiency. Other useful strategies in TENG designs for harvesting wind flow with high efficiency might be adapted for designing respiration-driven TENGs with enhanced performance. Respiration are closely associated with human health. Electricity output of TENG reflecting respiration characteristics thus may possess a great value for developing self-powered healthcare monitoring systems with potential applications for respiration behavior recognition, respiration rate and depth monitoring, and respiratory disease detection. 25, 26, [66] [67] [68] [70] [71] [72] [88] [89] [90] Wang et al developed an intelligent wireless TENG system to monitor the airflow during respiration. 66 The operation of TENG was based on aeroelastic fluttering of a flexible nanostructured PTFE (n-PTFE) thin film in an acrylic tube ( Figure 3A) . It was found that the average values of voltage and current rose monotonically from 1.7 to 11.1 V and 0.9 to 10.2 μA, respectively, when the air flow rate increased from 85 to 216 L/min. This monotonic and sensitive response of TENG to airflow rate enabled respiration monitoring. A mask built with the TENG could provide distinguishing electric output features under different respiration patterns ( Figure 3B) . Specifically, slow breath in sleep induced low-frequency 1.2 V peaked at the middle of electrical envelop. Rapid breath associated with exercise generated voltage envelop with a larger amplitude up to 1.8 V. Shallow breath in a coma situation exhibited a much weaker voltage of only 0.2 V. Deep breath was featured with a high voltage over 1 V and the longest duration up to 1.3 seconds. Therefore, human respiration behavior and related body status could be directly recognized based on the voltage patterns. Based on this device, an intelligent wireless respiratory monitor and alert system was demonstrated. When the TENG yielded voltage envelopes under normal breathing, active discrete square signal and zero switch signal was provided by the circuit (Figure 3C ). Once the breath pattern reached a critical situation (eg, no breath for more than 5 seconds), an alarm would be triggered through a wireless module and a warning massage would be sent to the cell phone. An early intervention could be initiated to help the patient. Instead of alerting at an emergency, Zhang et al also proposed utilizing a similar TENG device to build a human-machine interaction system to remotely manipulating appliances for disabled people by recognizing their breathing behaviors. 67 A smart textile TENG (t-TENG) was developed by Zhao et al to monitor respiration rate and depth. 25 The t-TENG was fabricated by direct weaving of Cu-coated polyethylene terephthalate (Cu-PET) warp yarns and polyimide (PI)-coated Cu-PET (PI-Cu-PET) weft yarns on an industrial sample weaving loom ( Figure 3D ). The energy harvesting fabrics could generate electric output at the yarn crisscross intersections upon any mechanical displacement. A maximum V OC of 5 V was reached. By directly integrating the fabrics into a chest strap, the rate and depth of respiration could be monitored in real-time ( Figure 3E ). Expansion and contraction of chest during respiration yielded a V OC at the 0.1 V level. Counting the number of voltage peaks during a specific time interval, the respiration rate could be precisely deduced. Furthermore, relationship between tidal volume V T and V OC was determined to be V T / V 1=2 OC , which allowed evaluation of respiration depth. Other TENG prototypes monitoring respiratory rate have also been reported. A soft band with a CS-mode TENG was designed to work as a sheet without direct skin contact. With a high dynamic-pressure sensitivity of 18.98 V kPa −1 within a wide working range of 40 kPa, this device could generate consistent electricity (0.2 V) when people lying on top of it. 89 A respiration rate could also be directly obtained from the number of voltage peaks. A smart belt built with a sliding-mode TENG and a wireless transmission chip was developed by Zhang et al. 72 The variation of the abdominal cavity circumference induced relative sliding of the triboelectric pair to generate voltage output. The electrical signal could be transmitted through a battery-powered wireless chip to a mobile phone in real time. Through this device, the respiratory rate was precisely recorded when the person was lying, sitting, standing, and walking. In addition to respiration monitoring, the direct relationship between breath pattern and voltage output of TENGs could be further used to detect obstructive sleep apnea-hypopnea syndrome (OSAHS), a respiratory disease due to upper airway obstruction during sleep. 71 In this work, a conductive yarn composed of polyester and 71 OSAHS, obstructive sleep apnea-hypopnea syndrome; TENG, triboelectric nanogenerator stainless steel was enwrapped with silicone outer sheath to form the triboelectric fiber, with which a single-layered t-TENG was fabricated ( Figure 3F ). The t-TENG exhibited a high sensitivity of 10.79 mV/Pa at a wide frequency bandwidth (0-40 Hz). Being placed on a mattress as a bedsheet, this t-TENG could record the real-time respiration rate once a patient was lying on top of it. Unlike stable electrical signals from healthy person, the OSAHS patient had distinct blanks in the voltage patterns due to apnea caused by the narrowed airway ( Figure 3G ). An OSAHS monitoring and intervention system was thus built based on this t-TENG, which could identify the apnea episodes and provide a timely alarm to the patient for recovering the normal breath. In general, respiration-driven TENG devices hold intriguing promises for respiratory healthcare monitoring with a few successful demonstrations. So far, the entire monitoring system usually consists of multiple modules including TENG, signal processor, wireless transmission, signal receiver, and analyzer. These systems are bulky and not fully wearable, raising concerns for convenience and practicality. An all-in-one integrated wearable system with miniaturized size is desired. Moreover, the accuracy of long-term monitoring as well as the stability of TENG system should be further investigated particularly under real application environment. Masks are an essential typical of personal protective equipment that filters hazardous particles including viruses from airborne, such as the COVID-19 virus. 91, 92 Most particulate respirators have layered filters consisting of webs of nanofiber/microfiber to block particles while allow for air to go through. It is based on the mechanisms of gravitational settling, interception, diffusion, and electrostatic attraction. 93 Since triboelectrification is one of the common electrostatic phenomena, one could either use a TENG to charge the filters or make filters as triboelectric pair to purify the air. [94] [95] [96] Liu et al. demonstrated a TENG-based mask fully driven by respiration. 97 The inlet of this mask had a Cu film and electrospun PVDF (ESP-PVDF) on a nonwoven substrate. A positive pressure from expiration pushed the Cu film to make full contact with the ESP-PVDF layer; while a negative pressure due to inspiration stretched the Cu film back to separate from the ESP-PVDF. This repeating process could generate and maintain the electrostatic charge on the fiber film ( Figure 4A ). Therefore, as large particles being removed by physical filtration through the porous structure, small particles were attracted and removed by electrostatic absorption. The TENG-based mask showed almost the same efficiency as the mask only containing ESP-PVDF at the initial stage (97.5% particle removal rate). After 240 minutes of continuous work, the TENGbased mask showed a fairly stable removal efficiency, while this efficiency of non-TENG masks were significantly reduced. Particularly, for ultrafine particles (25 nm to 1 μm) the TENG-based mask remained a 77.5% to 93.5% removal efficiency, while the value was dropped to only 32.3% to 68.4% for non-TENG masks ( Figure 4B) . Impressively, the TENG-based mask maintained a removal efficiency over 86.9% for particles below 0.5 μm and over 99.2% for particles over 1 μm for 30 days ( Figure 4C ), illustrating high removal efficiency and great durability. Although using TENG might significantly enhance the electrostatic adsorption, a disadvantage of this electrostatic mask is that the static charge could fluctuate considerably and would be easily affected by multiple factors including temperature, humidity, and air speed. Particularly, since the exhaled air from respiration contains high humidity, it could largely undermine the electrostatic charge generation capability. To make this intriguing development practical, it is necessary to design and engineer a TENG device that can maintain a high performance with minimal impacts from environmental factors. Because the absorption of gas molecules on the triboactive material surfaces could change its electrical properties (such as permittivity), the electrical output of TENG would vary upon gas molecule absorption. Therefore, by utilizing gas-responsive materials as the dielectric materials for charge generation, TENG could be designed for gas sensing without the need of additional power. [98] [99] [100] [101] Wang et al developed a respiration-driven TENG system that could detect trace-level NH 3 in the exhaled air. 98 NH 3 is a biomarker for diagnosing certain diseases (such as ulcers). This system contained an elastic balloon and a CS-mode TENG consisting of nanostructured PDMS and Ce-doped ZnO-polyaniline nanocomposite films ( Figure 4D ). The balloon was used to store the exhaled air and then to push the air to activate the TENG. Thus, a high sensitive to components in the exhaled air could be achieved. The output voltage monotonously decreased as the concentration of NH 3 increases. This TENG exhibited a good sensitivity (13.66 ppm −1 , R 2 = .9928) when exposed to trace-level NH 3 with a concentration from 0.1 to 1 ppm ( Figure 4E ). An excellent selectivity was also observed to NH 3 with a significantly higher response value of 0.25 compared to other gases at 0.01-0.02. By using WO 3 as the gas-responsive material, Su et al made an alveolus-shaped TENG sensor possessing a high sensibility toward NO 2 , which is the cause of pulmonary edema and respiratory diseases ( Figure 4F ). 99 The gas inflation and deflation due to respiration could enable the CS between the latex film and the sensitive WO 3 film, F I G U R E 4 Filtration and gas sensing by respiration-driven TENGs. A, Schematic of a TENG-based smart mask filtering particles and its working mechanism. Inset is an SEM image of PVDF-ESNF. B, Removal efficiencies of PVDF-ESNF and TENG masks. C, Durability test on removal efficiency of the smart mask integrated with TENG after 30 days. Reproduced with permission: Copyright 2018, the American Chemical Society. 97 D, Schematic illustration of a respiration-driven TENG sensor. E, Response-NH 3 concentrations fitting curve of the TENG. Inset is the selectivity of TENG to NH 3 and other interference gases. Reproduced with permission: Copyright 2019, Elsevier. 98 F, A digital image of a gas-sensing TENG. Inset is the schematic of the Alveolus-inspired TENG. G, Selectivity of the TENG to NO 2 and other interference gases. H, Response-NO 2 concentrations fitting curve of the TENG. Reproduced with permission: Copyright 2020, the American Chemical Society. 99 ESNF, electrospun nanofiber film; PVDF, polyvinylidene fluoride; TENG, triboelectric nanogenerator and generate electricity. A high response of 340.24% and linearity of 0.976 were achieved when this sensor was exposed to 80 ppm of NO 2 ( Figure 4H ). In addition, the response toward NO 2 was over 20 times higher than those from other gases such as CO, H 2 S, SO 2 , NH 3 , and CO 2 ( Figure 4G ), indicating an excellent selectivity. Another alcohol analyzer was developed by using TENG as the power source. Instead of directly detecting the adsorbed gas molecules, Wen et al utilized a respirationdriven sliding-mode TENG to power a gas sensor for alcohol sensing. 101 In this design, the solid-state sensor could be selected and design more independently to TENG material selection. Still powered by respiration energy, this tandem system achieved a high detection gas response of 34, fast response time of 11 seconds, and recovery time of only 20 seconds. Compared to other applications, gas sensing of TENG is largely immature. Although a few good gas sensing phenomena of respiration-driven TENG have been demonstrated, the general performance is still not comparable to regular solid state sensors. One key limitation is the selection of the gas-sensitive materials, which are typically not strong for triboelectric charge generation. Since it is mostly used on human, several additional issues such as flexibility, biocompatibility, durability, and wearability also need to be investigated and improved. Stimulation and activation of certain cells, organs and systems in human body by low-dose electricity have long been demonstrated. [102] [103] [104] [105] [106] [107] The periodic biphasic pulselike electrical signals generated from TENG were also found capable of modulating cell activities, such as accelerating proliferation, adjusting orientation, stimulating motility, and improving differentiation. 32,108 Therefore, the all-time accessible respiration energy guarantees a continuous operation of TENG to provide consistent electric pulses for therapeutic electrostimulation. Long et al fabricated a respiration-activated electrotherapy bandage consisting of a sliding-mode TENG and a pair of dressing electrode to accelerate skin wound healing. 109 The TENG was made by overlapping the metal/PTFE layer with another metal layer on different sides of the PET substrate ( Figure 5A ). When wrapping the device around the chest area of a Sprague Dawley rat, the expansion and relaxing of chest drove the PTFE layer sliding back and forth and provided a potential of 1.2 V between the dressing electrodes. The accelerated wound recovery was hypothesized based on the endogenous electric field effect on wound site recovery ( Figure 5B ). The disruption of transepithelial potential enhanced the endogenous electric field at the wounded area for epithelial cells to initiate directional migration into the dermal wound bed until the skin regeneration process was completed. To demonstrate the accelerated wound healing process, a proximal wound was created on the rat and the two dressing electrodes were aligned over the wound. After 3 days, the wound exposed to an electric field was nearly closed (Figure 5C ), whereas the control wound was still largely open. Quantitative study revealed that in the presence of electric fields, the wound reduced rapidly and reached a nearly complete closure (94% ± 4.3%) within the first 48 hours. Without the electric field, the wounded area slowly reduced to 30% within the first 150 hours ( Figure 5D ). Microscopy study of living fibroblasts showed that the electric field generated by TENG could facilitate the fibroblasts differentiating into myofibroblasts, thereby providing a contraction force for wound closure. Additionally, several important growth factors for wound recovery, such as transforming growth factor beta, epidermal growth factor (EGF), and vascular EGF, all showed enhanced expressions in TENGstimulated tissues. This self-stimulated electrotherapy for wound healing could have large impacts on a range of related diseases (eg, Raynaud's disease) and may resolve cosmetic concerns, such as chickenpox scars, acne, keloid scarring, or rosacea. One deficiency might be that this motiontriggered device delivered electricity with a frequency controlled by the respiration rate. Clinical applications of electrotherapy may require an optimal combination of frequency and amplitude to deliver desired treatment. This discrepancy is very challenge to address in current motion-triggered TENG designs. Most current IMDs consume energy in the range of μW to mW, while the available energy from respiration could reach up to the Watt level. Owing to the capability of continuous electrical energy generation, respirationdriven TENG may serve as a unique self-sustainable electric power supply for IMDs eliminating the bulky and rigid chemical batteries. Diaphragm moves in a relatively large distance and involuntarily all day around. It is thus considered an ideal in vivo site for biomechanical energy supply. In this regard, Li et al developed an ultrasoft and stretchable implantable sliding mode TENG with higher output current and larger amounts of transported charge compared to CS-mode TENGs. 73 This TENG had a micrograting electrode design with a multilayered structure, including two symmetric electrode layers and one mobile layer for electrification (middle layer), packaged by Ecoflex elastomer ( Figure 6A ). Each electrode layer consisted of Cu/Cr interdigital electrodes (IDEs) deposited on a flexible PET substrate covered by a thin layer of PTFE. The middle mobile layer was comprised of a central PET film sandwiched between two PTFE film where Cu/Cr metal strips were deposited. In a typical micro-grating configuration, individual fingers of IDEs had a width of 100 to 900 μm (a 1 ) with a length of 1 cm (a 2 ) and separated by a gap of 100 μm (a 3 ). The width (b 1 ) and gap (b 3 ) of metal strips in the middle layer were reconfigured accordingly following the relations: a 1 = b 1 ; and b 3 = 2a 3 + a 1 . A central cavity was created inside encapsulation materials to ensure the free move of middle layer when the device was strained. This cavity design also significantly lowered the device's Young's modulus to 46 kPa, which was comparable to many soft tissues. When implanted in abdomen of a rat by connecting to the diaphragm, this TENG could function as a battery-free direct current micropower supply ( Figure 6B ). During normal breath, the up and down movement of diaphragm periodically stretched and relaxed the device, leading relative sliding of the center layers to produce groups of electric spikes (0.8 V measured at 1 MΩ) as shown in Figure 6C . When connected through a set of rectifier and capacitor, a LED could be continuously and stably lighted up by the anesthetized rat at a breath rate of 45/min after experiencing a short charging period (50-60 seconds) ( Figure 6D ). This result successfully demonstrated the feasibility of continuously powering a small electronic device solely by harvesting biomechanical energy. As one of the most important and broadly used IMDs, cardiac pacemaker consumes electrical energy of 10-15 μW, which is within the range of typical TENG outputs. Zheng et al. demonstrated the promises of powering a pacemaker by a respiration-driven TENG. 30 Such a selfpowered pacemaker prototype was built by integrated a CS-mode TENG with a pacemaker through a rectifying bridge and a capacitor. The TENG was fabricated from a microstructured PDMS film and an Al foil. The TENG device was either implanted under the chest skin or fixed in between the diaphragm and the liver. When the rat was in anesthesia, the device positioned on chest produced an AC electricity of ±3 V and ±0.1 μA at a fast respiration rate of 1 Hz. The one placed under diaphragm output higher current up to 0.6 μA ( Figure 6E ) at a lower respiration rate (0.4 Hz). Through the full-wave rectifying bridge, a 10 μF capacitor was charged from 2 to 3 V within 275 minutes by a TENG in vitro (equivalent to 13 750 breathing cycles if implanted under chest). This amount of electrical energy was used by the pacemaker to generate heart stimulation pulses at various F I G U R E 5 Electrostimulation by respiration-driven TENGs. A, Schematic of a TENG-driven electrostimulation device for wound recovery. Insets are a digital image of device (left bottom) and a rat wearing the device (right top), respectively. B, Wound-healing mechanism under endogenous electric field. C, Digital images of the healing process with and without the TENG electric filed. D, Wound area as a function of time with (Experiment) and without the TENG electric filed (Control). Reproduced with permission: Copyright 2018, the American Chemical Society. 109 TENG, triboelectric nanogenerator frequencies from 2 to 5 Hz to regulate the heart rates of the rat ( Figure 6F ). In general, the respiration-driven TENG holds great promises as a self-sustainable power source for IMDs. However, the few preliminary studies are still very far away from clinical applications. Many more fundamental developments including packaging, long-term impact to respiration, stability of electricity output, and power management and regulation need to be investigated to support future clinical studies. Other technologies such as PENG [110] [111] [112] [113] [114] and electromagnetic generator (EMG) [115] [116] [117] [118] [119] have the capability of harvesting respiration energy and realize self-powered biomedical system as well. However, the TENGs still stands out with unique merits. Table 2 compiles detailed information of each technology. Apparently, TENG has outperformed PENG in terms of maximal power and energy conversion efficiency, although they have quite similar properties in other aspects (such as weight and size). The concurrent TENG driven by human respiration could achieve 0.75 mW output, which was over 10 times higher than that of PENG. TENGs possess huge advantages over EMGs when the device volume and weight are critical, because they have close maximal power. The new generation of biomedical devices has the trend toward miniaturization and light weigh where the EMGs could hardly be competent. While the majority of biomedical devices are still powered by batteries with rigid encapsulation, the batteries could contribute up to 90% weight or volume of the 73 E, Current output of a TENG from diaphragmatic movement. Inset is the TENG sutured on diaphragm. F, Stimulation of rat heart by a pacemaker powered by the TENG in vitro. Reproduced with permission: Copyright 2014, Wiley-VC. 30 IMDs, implantable medical devices; TENG, triboelectric nanogenerator entire device. 48, 129 Despite the emergence of flexible/ stretchable batteries opening up possibilities for wearable and implantable bioelectronics, [123] [124] [125] [126] [127] [128] other potential issues including electrode delamination during deformation and leakage of toxic electrolyte still raise concerns for its practical applications. 130, 131 Moreover, taking account of IMDs, the replacement of or recharging the batteries requires substantial surgical or technical efforts, introducing additional suffering and complexity (infections and inflammations) to the patients. On the contrary, smaller, lighter, safer, and more effective and durable TENGs with constant output exhibit great promise in broad biomedical applications. This article provides an overview of respiration-driven TENG from both fundamental and application perspectives. It is well recognized by the community that the energy from respiration is sufficient and accessible, which can consistently fuel TENG devices to achieve versatile biomedical applications, such as electrical energy generation, healthcare monitoring, air filtration, gas sensing, electrostimulation, and powering IMDs. As summarized in Figure 7A , due to the best accessibility, 70% respirationdriven TENGs were designed for chest and mouth/nose operation. Among all application demonstrations, healthcare monitoring is the mostly studied application (>45%) primarily because that respiration is an important physiological indication closely associated with multiple health problems ( Figure 7B ). Despite the exciting earlystage demonstrations of respiration-driven TENGs, there exist a few critical challenges that need to be addressed to fulfill their promising role in practical applications. Although theoretical calculations and in-lab studies have shown a high power density (up to kW/m 3 ) and high energy conversion efficiency (80%) of TENG, respirationdriven TENGs only output an electrical power in the range of 0.1 μW to 1 mW. Given the available respiration energy of an average adult is 0.1 to 1 W, the so far achieved energy conversion efficiency was less than 1%. The most likely reason was related to the low mechanical energy utilization. Although all TENGs utilized flexible polymers, the device modulus was still orders of magnitudes higher than that of body tissues. Designing TENGs with tissuecomparable mechanical properties may maximize the mechanical displacement in response to respiration actions and thus reduce the mechanical energy loss. 2. Long-term device accuracy and stability. Triboelectrification as a typical electrostatic phenomenon could be easily affected by the ambient environment, particularly temperature and humidity. Though researchers have claimed that some specific designs of TENG could work under a wide range of humidity and temperature, the long-term effect of these elements on the performance of respiration-driven TENG (such as accuracy of monitoring and sensing) has not been systematically studied. Appropriate packaging strategies without affecting device performance should be developed to isolate the functional component of a TENG from the environment. Meanwhile, the durability of the TENG due to mechanical and chemical damage during friction should be considered simultaneously. 3. Interference with other body movement. TENG can pick up movements from all sensible body actions, which may result in interference with the electrical signals from respiration and lead to wrong conclusions. For a respirator monitoring TENG placed on chest, large movements from arms could also induce chest motions and make TENG to respond. This additional electrical signal would interfere the electrical signal for respiration rate or depth monitoring. How to differentiate the target signal from other interferences is critical for the achieving accurate sensing and monitoring. A potential solution might rely on advanced algorithms to filter interference and extract targeted data. 4. All-in-one self-powered system. At last but not least, while TENG is a small and flexible membrane-like device, the entire biomedical electronic system may contain many other modules for signal processing, transmission, receiving, and analyzing. Operation of multiple modules still require extra power supplies, and thus diminishes the meaningfulness of achieving a self-powered biomedical application. How to design an all-in-one miniaturized system that is fully integrated with and powered by a TENG device is of great significance as well as a great engineering challenge. This challenge is also beyond respiration-driven TENGs and is applicable to all other implantable energy harvesting devices for powering IMDs. Above critical challenges need short or long-term dedicated research efforts from multiple disciplines, including material science, mechanical engineering, electrical engineering, and of course biomedical engineering. Nevertheless, owing to its unique advantages, respiration-driven TENG technology will likely play a significant role in the next generation power sources for a wide range of biomedical applications. Human-powered wearable computing High-performance piezoelectric energy harvesters and their applications Proceedings of the 1999 IEEE International Symposium on Electronics and the Environment Energy harvesting from human and machine motion for wireless electronic devices Control of human inspiratory motoneurones during voluntary and involuntary contractions Effects of lung volume and involuntary breathing movements on the human diving response Mechanisms of voluntary movement Neural control of voluntary movement initiation Triboelectric nanogenerators as new energy technology for self-powered systems and as active mechanical and chemical sensors Progress in triboelectric nanogenerators as a new energy technology and self-powered sensors Triboelectric nanogenerators as new energy technology and self-powered sensors-principles, problems and perspectives Triboelectric nanogenerators as a new energy technology: from fundamentals, devices, to applications Triboelectric nanogenerator: a foundation of the energy for the new era Recent progress on flexible triboelectric nanogenerators for selfpowered electronics Chemical modification of polymer surfaces for advanced triboelectric nanogenerator development Flexible triboelectric generator Non-contact cylindrical rotating triboelectric nanogenerator for harvesting kinetic energy from hydraulics Effective anti-biofouling enabled by surface electric disturbance from water wave-driven nanogenerator A highly sensitive, self-powered triboelectric auditory sensor for social robotics and hearing aids Sequential infiltration synthesis of doped polymer films with tunable electrical properties for efficient triboelectric nanogenerator development Research update: materials design of implantable nanogenerators for biomechanical energy harvesting Nanogenerator for biomedical applications A paper triboelectric nanogenerator for self-powered electronic systems Single-electrode triboelectric nanogenerator for scavenging friction energy from rolling tires Machine-washable textile triboelectric nanogenerators for effective human respiratory monitoring through loom weaving of metallic yarns Expandable microspherebased triboelectric nanogenerators as ultrasensitive pressure sensors for respiratory and pulse monitoring Self-powered pulse sensor for antidiastole of cardiovascular disease Triboelectric nanogenerator enabled body sensor network for self-powered human heart-rate monitoring Self-powered, one-stop, and multifunctional implantable triboelectric active sensor for real-time biomedical monitoring In vivo powering of pacemaker by breathing-driven implanted triboelectric nanogenerator Symbiotic cardiac pacemaker Triboelectric nanogenerator accelerates highly efficient nonviral direct conversion and in vivo reprogramming of fibroblasts to functional neuronal cells Self-powered implantable electrical stimulator for osteoblasts' proliferation and differentiation Investigation of low-current direct stimulation for rehabilitation treatment related to muscle function loss using self-powered TENG system Self-powered direct muscle stimulation using a triboelectric nanogenerator (TENG) integrated with a flexible multiple-channel intramuscular electrode Effective weight control via an implanted self-powered vagus nerve stimulation device Self-activated electrical stimulation for effective hair regeneration via a wearable omnidirectional pulse generator Triboelectric nanogenerators: fundamental physics and potential applications Reviving vibration energy harvesting and self-powered sensing by a triboelectric nanogenerator Human Form, Human Function: Essentials of Anatomy & Physiology Mechanics of breathing in man Mechanics of respiration The energy cost (work) of breathing Improving power output for vibration-based energy scavengers Paper presented at: VLSI Circuits and Systems II Comparison of energy harvesting systems for wireless sensor networks Kinetic and thermal energy harvesters for implantable medical devices and biomedical autonomous sensors Power approaches for implantable medical devices Proceedings of the World Congress on Engineering USENIX Annual Technical Conference Polymer-based nanogenerator for biomedical applications Theoretical study of contact-mode triboelectric nanogenerators as an effective power source Theory of sliding-mode triboelectric nanogenerators Flutter-driven triboelectrification for harvesting wind energy Aeroelastic flutter energy harvesters self-polarized by triboelectric effects Flow-induced snap-through triboelectric nanogenerator A nanogenerator for harvesting airflow energy and light energy A flutter-effect-based triboelectric nanogenerator for breeze energy collection from arbitrary directions and self-powered wind speed sensor An aeroelastic flutter based triboelectric nanogenerator as a self-powered active wind speed sensor in harsh environment Fluid-flow-induced flutter of a flag Formulas for Natural Frequency and Mode Shape Aeroelastic instability of cantilevered flexible plates in uniform flow Fluttering flags: An experimental study of fluid forces Elastoaerodynamics-driven triboelectric nanogenerator for scavenging air-flow energy Concurrent harvesting of ambient energy by hybrid nanogenerators for wearable self-powered systems and active remote sensing Air-flow-driven triboelectric nanogenerators for self-powered real-time respiratory monitoring Breath-based human-machine interaction system using triboelectric nanogenerator Waist-wearable wireless respiration sensor based on triboelectric effect Triboelectric nanogenerator using microdome-patterned PDMS as a wearable respiratory energy harvester Stretchable-rubber-based triboelectric nanogenerator and its application as self-powered body motion sensors Single-layered ultra-soft washable smart textiles for all-around ballistocardiograph, respiration, and posture monitoring during sleep A portable triboelectric nanogenerator for real-time respiration monitoring Implanted battery-free direct-current micro-power supply from in vivo breath energy harvesting A semi-quantitative tribo-electric series for polymeric materials: the influence of chemical structure and properties Single-electrode triboelectric nanogenerators based on sponge-like porous PTFE thin films for mechanical energy harvesting and self-powered electronics Triboelectric touch-free screen sensor for noncontact gesture recognizing Base-treated polydimethylsiloxane surfaces as enhanced triboelectric nanogenerators Washable textile-structured single-electrode triboelectric nanogenerator for self-powered wearable electronics Highly stretchable 2D fabrics for wearable triboelectric nanogenerator under harsh environments Micro-cable structured textile for simultaneously harvesting solar and mechanical energy Study of long-term biocompatibility and bio-safety of implantable nanogenerators Biocompatibility and in vivo operation of implantable mesoporous PVDF-based nanogenerators Transparent triboelectric nanogenerators and self-powered pressure sensors based on micropatterned plastic films Nanopillar arrayed triboelectric nanogenerator as a self-powered sensitive sensor for a sleep monitoring system Formation of triboelectric series via atomic-level surface functionalization for triboelectric energy harvesting Enhancing performance of triboelectric nanogenerator by filling high dielectric nanoparticles into sponge PDMS film Surface texturing and dielectric property tuning toward boosting of triboelectric nanogenerator performance Membrane-based self-powered triboelectric sensors for pressure change detection and its uses in security surveillance and healthcare monitoring Noncontact heartbeat and respiration monitoring based on a hollow microstructured selfpowered pressure sensor Self-powered nanofiber-based screen-print triboelectric sensors for respiratory monitoring Can N95 respirators be reused after disinfection? How many times? Rational use of face masks in the COVID-19 pandemic On the minimum efficiency and the most penetrating particle size for fibrous filters Triboelectric nanogenerator enhanced nanofiber air filters for efficient particulate matter removal Removal of particulate matter emissions from a vehicle using a self-powered triboelectric filter Washable multilayer triboelectric air filter for efficient particulate matter PM2. 5 removal Self-powered electrostatic adsorption face mask based on a triboelectric nanogenerator A facile respiration-driven triboelectric nanogenerator for multifunctional respiratory monitoring Alveolus-inspired active membrane sensors for self-powered wearable chemical sensing and breath analysis An integrated flexible selfpowered wearable respiration sensor Blow-driven triboelectric nanogenerator as an active alcohol breath analyzer Low intensity transcranial electric stimulation: safety, ethical, legal regulatory and application guidelines Noninvasive brain stimulation with low-intensity electrical currents: putative mechanisms of action for direct and alternating current stimulation Directly applied low intensity direct electric current enhances peripheral nerve regeneration in rats Low-intensity electromagnetic and mechanical modulation of bone growth and repair: are they equivalent? Transcutaneous electrical nerve stimulation The application of nanogenerators and piezoelectricity in osteogenesis Self-powered electrical stimulation for enhancing neural differentiation of mesenchymal stem cells on graphene-poly (3,4-ethylenedioxythiophene) hybrid microfibers Effective wound healing enabled by discrete alternative electric fields from wearable nanogenerators Development of a piezoelectric polyvinylidene fluoride (PVDF) polymer-based sensor patch for simultaneous heartbeat and respiration monitoring Flexible piezoelectric nanogenerator in wearable self-powered active sensor for respiration and healthcare monitoring Design of an ultrasensitive flexible bend sensor Using a silver-doped oriented poly (vinylidene fluoride) nanofiber web for respiratory monitoring PVDF microbelts for harvesting energy from respiration An active self-driven piezoelectric sensor enabling real-time respiration monitoring Paper presented at: Active and Passive Smart Structures and Integrated Systems XII Paper presented at: 2013 35th Annual International Conference of the Paper presented at: IECON 2012-38th Annual Conference on IEEE Industrial Electronics Society Paper presented at: 2011 IEEE Power and Energy Conference at Illinois Annual International Conference of the IEEE Engineering in Medicine and Biology Society Mechanical efficiency of breathing A review on heat and mechanical energy harvesting from human-principles, prototypes and perspectives Mechanical work of breathing during exercise in trained and untrained subjects Flexible, solid electrolyte-based lithium battery composed of LiFePO 4 cathode and Li 4 Ti 5 O 12 anode for applications in smart textiles Progress in flexible lithium batteries and future prospects Self-weaving sulfur-carbon composite cathodes for high rate lithium-sulfur batteries Bendable inorganic thin-film battery for fully flexible electronic systems Flexible and biocompatible high-performance solid-state micro-battery for implantable orthodontic system Decoupling of mechanical properties and ionic conductivity in supramolecular lithium ion conductors Batteries used to power implantable biomedical devices. Electrochim Acta Issues and challenges facing flexible lithium-ion batteries for practical application Flexible rechargeable lithium ion batteries: advances and challenges in materials and process technologies His current research interests include understanding the coupling effect between piezoelectric polarization and semiconductor functionalities; developing advanced nanomaterials and nanodevices for mechanical energy harvesting from human activities and ambient environment; and studying the growth mechanisms and developing assembly techniques of oxide nanostructures. He is the author of more than 150 publications and holds more than 10 patents on oxide and piezoelectric materials processing and applications.How to cite this article: Li J, Long Y, Yang F, Wang X. Respiration-driven triboelectric nanogenerators for biomedical applications. EcoMat. 2020;1-19. https://doi.org/10.1002/eom2. 12045