key: cord-0960585-w2m3vnr2 authors: Corpuz, Mary Vermi Aizza; Buonerba, Antonio; Vigliotta, Giovanni; Zarra, Tiziano; Ballesteros, Florencio; Campiglia, Pietro; Belgiorno, Vincenzo; Korshin, Gregory; Naddeo, Vincenzo title: Viruses in wastewater: occurrence, abundance and detection methods date: 2020-07-19 journal: Sci Total Environ DOI: 10.1016/j.scitotenv.2020.140910 sha: a0fcc1b4aaf5de904741012b7eb4638f99f4ed04 doc_id: 960585 cord_uid: w2m3vnr2 Abstract This paper presents an updated and comprehensive review on the different methods used for detection and quantification of viruses in wastewater treatment systems. The analysis of viability of viruses in wastewater and sludge is another thrust of this review. Recent studies have mostly focused on determining the abundance and diversity of viruses in wastewater influents, in samples from primary, secondary, and tertiary treatment stages, and in final effluents. A few studies have also examined the occurrence and diversity of viruses in raw and digested sludge samples. Recent efforts to improve efficiency of virus detection and quantification methods in the complex wastewater and sludge matrices are highlighted in this review. A summary and a detailed comparison of the pre-treatment methods that have been utilized for wastewater and sludge samples are also presented. The role of metagenomics or sequencing analysis in monitoring wastewater systems to predict disease outbreaks, to conduct public health surveillance, to assess the efficiency of existing treatment systems in virus removal, and to re-evaluate current regulations regarding pathogenic viruses in wastewater is discussed in this paper. Challenges and future perspectives in the detection of viruses, including emerging and newly emerged viruses such as the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), in wastewater systems are discussed in this review. Viruses are ubiquitous and persistent in raw wastewater and treated wastewater as well as in the receiving water bodies (Fumian, Leite et al., 2010) . One of the main sources of viruses, including viral pathogens in wastewater is the human fecal matter, particularly that from infected persons (Gerba et al., 2017; Hellmér et al., 2014a; Symonds et al., 2009) . Sewage systems receive enteric viruses excreted by infected individuals. An infected person sheds 10 5 to 10 12 viral particles per gram of fecal matter (Gerba, 2000) . In addition to human pathogenic viruses, waterborne viruses that originate from food production, animal husbandry, seasonal surface runoff and other sources are present in wastewater (Corsi et al., 2014) . The bodies that receive treated wastewater are oftentimes used for recreational activities and agriculture, and as a source of raw water for drinking water production (Corsi et al., 2014; Dias et al., 2019) . Effluents from wastewater treatment plants (WWTPs) are widely used for irrigation and for aquifer recharge (Gerba et al., 2017) . The presence of potentially pathogenic viruses in wastewater is of concern since it can pose risks to human health (Carducci et al., 2009) . Sludges from wastewater treatment plants are also utilized for agricultural applications as soil conditioner or fertilizer (Andreadakis et al., 2002; Bibby and Peccia, 2013; Grobelak et al., 2019) . Aside from the concerns related to reuse of wastewater and sludge, exposure of WWTP workers to viral pathogens is a potential risk. Aeration facilities in WWTPs generate and diffuse bioaerosols containing chemicals and microorganisms including viruses that are typically non-waterborne (Pasalari et al., 2019; . Aerosols are also emitted during the handling of sludge and land application of biosolids (Bibby and Peccia, 2013) . The abundance and diversity of pathogenic viruses in wastewater has been shown to reflect the pattern of infection in human population ( Fumian, Leite et al., 2010; Montazeri et al., 2015) . J o u r n a l P r e -p r o o f 8 Adenovirus (HAdV), rotavirus (RoV), hepatitis A virus (HAV), and other enteric viruses, such as noroviruses (NoV), coxsackievirus, echovirus, reovirus and astrovirus are some of the principal human pathogens viruses transmissible via water media. Enteric viruses cause waterborne diseases such as diarrhea in children and in adults (Pietruchinski et al., 2006) and are associated with other disease outbreaks (Thongprachum et al., 2018) . Enteric viruses may lead to symptoms notably nausea, vomiting, and fever (Bishop and Kirkwood, 2008) . In addition to diarrhea and other gastrointestinal diseases, some enteric viruses have been related to respiratory diseases such as bronchiolitis (Kocwa-Haluch, 2001 ). The aims of quantification of viruses in wastewater include: i) the determination of the level of risk associated to waterborne diffusion of viruses, ii) the evaluation of the efficiency of disinfection as measure of control of virus, iii) the surveillance on the extent of diffusion of viruses in a population (Barcelo, 2020) . These objectives can be met by determining both the concentration of virus and its infectivity. Virus requires a host species for replication therefore, in absence of the latter, the concentration of a virus in an environment can be constant or progressively reduced by inactivation. Table 1 and Figure 1 report literature data concerning the range of concentrations and viability of representative viruses that can populate wastewater both continually (e.g., enteric viruses) and sporadically (e.g., coronaviruses during an epidemic). It can be observed that WWTP processes are not completely effective in the reduction of viral genomes' concentrations of most viruses in wastewater (Table 1) . For a complete information on the presence of viruses in water, as well as in other environments, their viability and corresponding potential infectivity should also be investigated. This information is an essential input for determining pathways of virus transmission, quantifying the extent of disease risk, and J o u r n a l P r e -p r o o f 9 identifying interventions through the use Quantitative Microbial Risk Assessment (QMRA) and Infectious Disease Transmission Modeling (IDTM) (Brouwer et al., 2018) . Enteric viruses are non-enveloped viruses with an enhanced resistance. Some enteric viruses such RoV have been shown to be resistant to UV disinfection. The resistance is attributed to its structure, specifically to the presence of a double-stranded RNA and three-layered capsid protein (Li et al., 2009 ). On the contrary, enveloped viruses are more susceptible to inactivation in wastewater. The presence of solvents, detergents and disinfectant in wastewater rapidly compromise the lipidic viral envelope or the surface protein. Severe Acute Respiratory Syndrome (SARS) coronavirus (SARS-CoV-1), an enveloped virus, was found to be persistent in raw sewage at 20 0 C for 2 days and 14 days at 4°C (Wang et al., 2005b (Wang et al., , 2005c . A limited number of studies have shown that the viability of SARS coronaviruses has not been observed in effluent from WWTPs (see Table 1 ). SARS-CoV-1 has also been reported by Wang et al. (2005c) to be inactivated by free chlorine with concentration greater than 0.5 mg/L and by chlorine dioxide with concentration greater than 2.19 mg/L. Mechanisms of removal of viruses from WWTP include adsorption of viruses on larger aggregated particles that are separated from wastewater by sedimentation (Verbyla and Mihelcic, 2015) , retention by membrane and biofilm layers, predation and enzymatic breakdown in membrane bioreactors (Chaudhry et al., 2015) , and inactivation by disinfection processes such as UV, chlorination, and ozonation (Xagoraraki et al., 2014) . As discussed, the resistance of the viruses to inactivation mechanisms is influenced by the viral structure. Double-stranded viruses, including reovirus, HAdV and RoV, have been shown to be generally more resistant to UV radiation than single-stranded ones (Calgua et al., 2014; Harris et al., 1987; Li et al., 2009) . This behavior of the double-stranded viruses is attributed to the capability to repair their genomes during replication in the host cells (Beck et al., J o u r n a l P r e -p r o o f 10 2014; Calgua et al., 2014) . In addition to the influence of the viral structure to inactivation, some WWTP processes also reduce the rate of inactivation of viruses. Although adsorption of viruses to solids contributes to their removal from wastewater, this also provides a degree of protection of the viruses from inactivation (Hejkal et al., 1981) . This paper aims to present and compare the currently developed methods of detection and quantification of viruses in wastewater. It also aims to present a review of the different pretreatment steps needed to increase the efficiency of detection and quantification methods of viruses in wastewater and associated products. In this paper, particular attention is paid to the detection and quantification of the recently emerged SARS-CoV-2. This virus belongs to the Coronaviridae family, characterized by a protein capsid, containing the viral RNA, protected by a bilipidic envelope with embedded spike proteins. This virus can be transmitted by inhalation of infected respiratory particles , though other potential routes of transmission have been postulated to be important, notably via fomites (van Doremalen et al., 2020) , ocular surface , and fecal-oral route (Y. Xiao et al., 2020; Yeo et al., 2020) . SARS-CoV-2 has been reported to affect the human gastroenteric tract (Ding and Liang, 2020) and the presence of the viral RNA was detected in fecal samples (Y. Xiao et al., 2020) and wastewater conveyed to WWTPs (Ahmed et al., 2020; La Rosa et al., 2020; Lodder and de Roda Husman, 2020; Medema et al., 2020; F. Wu et al., 2020; Wurtzer et al., 2020) . Therefore, the analysis of wastewater constitutes a powerful tool for surveillance of the propagation of diseases associated with pathogenic viruses. The presence of these different pathways highlights the importance of the control and removal of viruses in wastewater treatment. Correspondingly, the efficiency of treatment systems to remove viruses must be The accuracy of detection of viruses depends on the sample volume, nucleic acid extraction yield (for nucleic acid-based methods) and purity Haramoto et al., 2018; Hryniszyn et al., 2013; Sidhu et al., 2013) . A study conducted by Hjelmsø et al. (2017) showed that both the concentration of nucleic acids and the nature of the methods used for the extraction significantly influence the results of viral metagenomic analyses, particularly those of viral community composition, viral specificity, and viral pathogen detection. This means that the methods for concentration, nucleic acid extraction, and detection must be chosen appropriately. This section presents a summary of concentration methods of wastewater samples, pre-treatment methods for sludge samples, and nucleic acid extraction methods. The processing of a sample collected for detection and quantification of viruses depends on the type of sample matrix. Influents generally have higher concentration of viruses than other environmental samples (Haramoto et al., 2018) . Raw wastewater samples have higher turbidity J o u r n a l P r e -p r o o f 12 (Falman et al., 2019; Qiu et al., 2016; Sidhu et al., 2013) , higher suspended solids and higher organic matter concentrations (Falman et al., 2019) than other environmental water samples. In addition, influent wastewaters have high concentrations of humic acids and heavy metals, that may interfere with the molecular methods of assaying for viruses . On the other hand, sludges are very heterogeneous sample matrices, in which viruses tend to be adsorbed on the surface of the flocs (Symonds et al., 2014) . These characteristics affect the accuracy of the detection of viruses in these samples. This necessitates the use of concentration steps, some of which consist of primary and secondary concentration methods. It should be noted that molecular methods for detection and quantification of viruses do not provide complete information on the infectivity of viruses present in water media. Those methods determine the presence of molecular fragments (DNA or RNA) of the viruses. The viability of a virus can be determined through the cytopathogenic effect of the infected sample in suitable cell lineages that act as a host species for the virus. Therefore, for the reliable determination of this parameter it is important to preserve the viability of the virus during the sampling, the handling and the treatment of the wastewater sample. A summary and comparison of different types of concentration methods used in processing samples for detection of viruses from wastewater treatment plants are presented in the following discussion and summarized in Table 2 . Viruses can be removed from water matrices through adsorption onto a membrane filter and subsequent recovery by elution: a process named as virus adsorption-elution (VIRADEL). Metcalf (1961) first reported the recovery of influenza virus from aqueous suspensions through adsorption on a membrane filter. Wallis and Melnick (1967) examined the concentration of enteroviruses by dilution in salt solution to allow adsorption to membrane filters, and subsequent J o u r n a l P r e -p r o o f 13 elution. In the current VIRADEL method, the samples pass through a membrane filter that may have an electronegative or electropositive charge. The viruses are retained on the surface of the filter due to electrostatic attraction between viral particle and membrane surface . The VIRADEL method was developed for water samples with low turbidity . Modifications to this method are necessary for samples with high turbidity, such as influent wastewaters. Prado et al. (2011) pre-filtered influent hospital wastewater samples before electronegative membrane filtration. VIRADEL method has been widely used for large volumes of sample to be processed, notably river samples (Hamza et al., 2009; Maunula et al., 2012) , tap water samples (Hill et al., 2009; Polaczyk et al., 2007) , groundwater samples (Lee et al., 2011) , and coastal waters (Fong et al., 2005; Goyal and Gerba, 1983; Katayama et al., 2002) . Wastewater sample volumes ranging from 0.5 to 400 L were used in recent studies that applied VIRADEL as primary concentration method (Falman et al., 2019; Kuo et al., 2010; Masclaux et al., 2013; Osuolale and Okoh, 2017; Prado et al., 2011; Soto-Beltran et al., 2013) . However, the processing of large volumes of samples leads to the concentration of PCR inhibitors. The volume of sample to be treated must be adequate to ensure a final high viral content, keeping low that of PCR inhibitors, in order to facilitate the subsequent molecular amplification techniques of the nucleic material of the virus (Qiu et al., 2016) . This consequently improves the quality of viral DNA or RNA that will be extracted in the downstream processes. Aside from the difficulties associated to the handling of large volumes of samples, another disadvantage of VIRADEL is the number of steps, including: i) pre-filtration, ii) membrane adsorption, iii) elution, resulting to prolonged processing time and loss in yield of recovered viruses. (Qiu et al., 2016) 2.2.1. Electronegative filtration J o u r n a l P r e -p r o o f 14 The outer surface of non-enveloped viruses is composed of capsid proteins whose isoelectric point is typically below the pH of wastewater. Therefore, this class of viruses has a net surface negative electrical charge (Hamza et al., 2009; Mayer et al., 2015) . The use of electronegative membranes, common in VIRADEL methods, requires the lowering of the pH prior to filtration in order to induce the protonation of the protein capsid and the resultant inversion of the electrical charge of the viral surface (Hamza et al., 2009) . The positively charged viruses can then be adsorbed onto the surface of a negatively charged membrane (Cashdollar & Wymer, 2013; Hamza et al., 2009 ). The addition of salts, such as magnesium or aluminum chlorides improves the adsorption of the viruses on the negatively charged-membrane (Hamza et al., 2009; Haramoto et al., 2009; Masclaux et al., 2013; Osuolale and Okoh, 2017) . The first report on the adjustment of pH of suspension medium to 5.0 for optimum adsorption of poliovirus (PV) to membrane filters was made by Wallis and Melnick (1967) . Hamza et al. (2014) used a negatively charged membrane of 0.45 µm pore size for adsorption of human enteric viruses from sewage. The sample's pH was adjusted to 3.5 to modify the charge of the viruses and enhance the attraction to the electronegative membrane. Prado et al. (2011) concentrated effluent and prefiltered influent wastewater samples with gastroenteric and HAV using a negatively charged membrane. The recovery of the viruses through elution is done after the adsorption to the electronegative membrane. In some methods, the elution step is eliminated, and the nucleic acids of the viruses are directly extracted from the filter (Ahmed et al., 2015) . This latter method has been used to concentrate and directly extract nucleic acids of JC Polyomavirus (JCPyV) and BK Polyomavirus (McQuaig et al., 2009 ) and other enteric viruses (Ahmed et al., 2015) in environmental water samples. J o u r n a l P r e -p r o o f Electropositive membrane filters can be alternatively used in VIRADEL methods. On the basis of the electrical charge of virus suitable for adsorption on membrane filters, the adjustment of the sample pH to reverse the virus surface charge is not necessary when using electropositive membranes (Cashdollar and Wymer, 2013) . Soto-Beltran et al. (2013) examined the effectiveness of two electropositive filters in the concentration of PV from a WWTP's effluent (prior to chlorination stage). In that study, two methods of concentration using NanoCeram filter and 1MDS filter were compared in terms of virus recovery. Overall efficiencies of these methods were 57% for NanoCeram and 23% for 1MDS filter methods. The Virosorb 1MDS filter is made of an electropositive glass and cellulose medium (Polaczyk et al., 2007; Soto-Beltran et al., 2013) . The NanoCeram filter is made of nanoalumina fibers, which makes it electropositive Soto-Beltran et al., 2013) . After being retained by the filters, the viruses must be recovered through elution from the collection substrate (Pepper and Gerba, 2015) . For negative filter membranes, a common elution solution is an alkaline solution of beef extract in glycine buffer solution (Hamza et al., 2009 ). This solution is passed through the filter and results in the desorption of the retained viruses from the filter. The alkaline pH restores the native negative charge of the virus, resulting in an increased repulsion and subsequent desorption of the viruses from the filter membrane. In addition, the additive organic matter present in the buffer solution competes with the viruses for adsorption to the filter facilitating its removal. (Pepper and Gerba, 2015) J o u r n a l P r e -p r o o f 16 Other elution buffer solutions used include glycine/NaOH solution (Di Bonito et al., 2017; Miura et al., 2011) , sodium polyphosphate (Soto-Beltran et al., 2013) and skimmed milk (Cupples et al., 2010) to recover viruses from environmental samples. These elution buffer solutions are in the range of 70 ml to 1000 ml in volume (Falman et al., 2019; Hamza et al., 2009; Kuo et al., 2010; Prado et al., 2011; Soto-Beltran et al., 2013) . After elution of the viruses mobilized from the retaining membrane, the eluate frequently needs to undergo further re-concentration. The aim of this step is to reduce as much as possible the sample volume prior to nucleic acid extraction steps (Pepper and Gerba, 2015) . In a study by Falman et al. (2019) , the efficiency in recovery of PVs in wastewater was evaluated for several secondary concentration methods. Adsorption using an electropositive filter and elution with beef extract was used as a primary concentration method. The reported results showed that optimized flocculation with skimmed milk resulted in the efficient recovery of poliovirus type 1 (PV1) with yield of 106 ± 25 % while the yield with Polyethylene glycol (PEG) precipitation was 59±19%. This method relies on the principle of size-exclusion using membrane filters that have pore sizes that are smaller than the viral particles (Morales-Morales et al., 2003; Olszewski et al., 2005) . In a study conducted by Sidhu et al. (2018) , the concentration of influent and effluent wastewater treatment samples was done using a hollow fibre ultrafiltration system (HFUFS), followed by another filtration step with a 100K molecular weight cut-off filter. Results showed that the recovery of the HAdV was 37% from influent samples and 67% from effluent samples. A study J o u r n a l P r e -p r o o f by Prado et al. (2019) on the detection of enteric viruses from wastewater treatment plant samples used ultrafiltration as a primary concentration step, followed by celite-based secondary concentration. One disadvantage of this method is the small pore size of filters, leading to clogging of filters when samples have high turbidity. Grassi et al. (2010) concentrated raw and treated wastewater samples to detect RoV using tangential flow ultrafiltration. The tangential flow ultrafiltration method is generally suitable for high turbidity samples since clogging is prevented because the water flow is parallel to the membrane surface . kDa. Compared to the 10 L volume of sample needed in VIRADEL, this rapid concentration method used a lower input volume of 100 mL. The reported results showed that the centrifugal ultrafiltration method resulted in an efficient recovery that was comparable to that of the VIRADEL method. In another study by Sidhu et al. (2013) , centrifugal ultrafiltration was used to concentrate HAdV from 10 mL of primary wastewater samples. These latter studies utilized the input sample volume that was smaller compared to the amount needed using the VIRADEL technique. This allows for easier collection of samples, simpler processing, and shorter filtration time. This also allows processing of multiple samples simultaneously. (Qiu et al., 2016) J o u r n a l P r e -p r o o f 18 Centrifugal ultrafiltration does not require any pH adjustments before filtration and after elution, which is necessary in the electronegative filtration methods, thus maintaining the stability of viruses sensitive to pH variations. Polyethylene glycol (PEG) is an inert and biocompatible polymer frequently applied for precipitation of proteins. PEG acts as an -inert solvent sponge‖ (Atha and Ingham, 1981) sequestrating water molecules from the solvation layer surrounding the proteins of the viral capsid, enhancing the virus-virus interactions and resulting in the precipitation. Early applications of precipitation with PEG method to recover viruses from environmental samples include release of solids-associated viruses from wastewater and sludge samples (Wellings et al., 1976) and their use to concentrate viruses from shellfish, natural fresh and estuarine water, and freshwater sediment samples (Lewis and Metcalf, 1988) . Masclaux et al. (2013) utilized precipitation with PEG to concentrate Hepatitis E viruses in influent and effluent samples from municipal WWTPs. Another study by Strubbia et al. (2019) applied PEG to concentrate NoV from raw sewage samples. In the same study a modified PEG method (Pyro-PEG) was utilized, applying elution with sodium pyrophosphate and sonication prior the PEG precipitation step. An increased number of norovirus GI (NoV GI) and norovirus GII (NoV GII) concentrations in the treated wastewater samples was observed using Pyro-PEG in comparison to conventional PEG method. This increase in detection is attributed to the sonication step which released viral particles from organic matter and reduced the number of bacteria in the sample. The application of PEG in the study of Amdiouni et al. (2012) resulted to a high efficiency in the recovery of RNA viruses. This is useful for the concentration of viruses from wastewater J o u r n a l P r e -p r o o f 19 samples since several RNA viruses are present in wastewater (Adriaenssens et al., 2018; Ng et al., 2012) . As a drawback, PEG may result to non-selective precipitation because it induces the precipitation of various proteins, such as enzymes, that can interfere and even inhibit the subsequent detection of viral genome by PCR amplification methods (Masclaux et al., 2013; Shieh et al., 1995) . Skimmed milk flocculation, a concentration method first developed to recover adenoviruses from seawater Calgua et al. (2008) is also used to recover viruses from wastewater samples. This method relies on the physical processes including i) adsorption of viruses to pre-flocculated skimmed milk proteins, ii) sedimentation of the flocs with adsorbed viruses, and iii) dissolution of sediments using a phosphate buffer solution. The combination of elution with glycine buffer and the skimmed milk flocculation was successfully used by Calgua et al. (2013) to recover HAdV, JCPyV, and NoVGII from raw urban sewage samples. Assis et al. (2018) applied the skimmed milk flocculation for the recovery of HAdV and RoV from WWTP effluent samples. The latter study revealed that higher recovery rates of HAdV and RoV were obtained by eliminating the initial centrifugation step and by doubling the concentration of skimmed milk. The elimination of centrifugal step was done because of low solids in the treated effluent. An advantage of this concentration method is that it does not require special equipment and reduced number of processing steps, allowing simultaneous concentration of a large number of samples (Calgua et al., 2008) . Because sludge is a highly aggregated matrix, viruses must first be desorbed from the sludge through pre-treatment methods. (Pepper and Gerba, 2015) The traditional method used for pre-treatment of sludge samples is based on the American Wu and Liu (2009) used a modified method where sonication (50 kHz, 100 W) of the sample was conducted before the last centrifugation step. This pre-treatment step was conducted prior to the direct counting of viral particles by epifluorescence microscopy (EFM). The effect of sonication on the recovery was examined by varying the duration of sonication. The viral count after one minute of sonication was found to be significantly higher than that obtained without sonication. The sonication enhanced the desorption of viruses from the solid sludge and the release of viruses from their host cells. However, sonication carried out for longer than a minute led to lower viral counts, which may be attributed to possible damage to viral particles. Ultrasonication of activated sludge samples was applied by Ma et al. (2013) to separate viruses from the sample matrix, and subsequently increased the efficiency of flow cytometry (FCM), which requires a sample free of aggregated flocs. Aside from sonication, Brown et al. (2015) J o u r n a l P r e -p r o o f 21 used Tween 80, a non-ionic surfactant and emulsifier, and sodium pyrophosphate, an ionic dispersant, to enhance the dislodgement of viruses from the sludge matrix, demonstrating an increased efficiency of virus counting with FCM. Ultracentrifugation was also examined and compared to the beef extract elution method in recovering enteric viruses from primary sewage sludge samples. However, both methods resulted in less than 7.5% mean recovery of HAdV, Rotavirus A (RoV-A), NoV GII and HAV from the sludge. These results suggested that the applied concentration methods were unable to reduce the presence of the inhibitors that affected the subsequent PCR-based detections (Prado et al., 2014) . Enzymatic virus elution (EVE), a pre-treatment step that minimizes the content of PCR inhibitors in sludge samples, was studied by Sano et al. (2003) . Instead of the commonly used 10% beef extract as eluant, a solution containing hydrolytic enzymes (10 g/L) and a cation exchange resin (CER), at a concentration of 10 milliequivalents per liter (meq/L), was added to the sample pellets after the first centrifugation step. Hydrolytic enzymes used by Sano et al. (2003) were lysozyme, carboxylesterase, chymotrypsin, and papain. Multivalent cations present in the sample can enhance the adsorption of viruses to sludge flocs. The addition of CER sequestrates these cations, preventing the re-sorption of the viruses onto particle of sludge samples. In the study by Sano et al. (2003) , the efficiency of RT-PCR was increased by using the EVE method instead of the conventional elution with 10% beef extract. The overall increase in virus recovery efficiency (from 7% to 31%) resulting from the combined EVE method and RT-PCR was ascribed to: i) the reduction of the concentration of PCR inhibitors from the sludge, i.e. peptides decomposed by the additive hydrolytic enzymes, ii) the capture of multivalent cations by the cation exchange J o u r n a l P r e -p r o o f 22 resin; iii) the elimination of beef extract eluant, which is a source of further components which inhibit PCR amplification of viral genome (Hata et al., 2011; Rock et al., 2010) . Elution with beef extract and elution with glycine were compared by Rock et al. (2010) in terms of the reduction of PCR inhibitors present in biosolids or treated sewage sludges. Excitationemission spectroscopy results showed that the natural organic matter levels were higher in the samples eluted with beef extract than in samples eluted with glycine. Lower organic matter levels led to higher amplification efficiency of PV genome by RT-qPCR. In the PCR-based methods, the target sequence of the genome material of the virus is amplified. Viruses have genome materials that are either RNA or DNA (Artika et al., 2020) . The viral genome materials may be classified as single-stranded or double-stranded. Nucleic acid strands have different polarities, whether positive (+) or negative (-). The viral genome structures are either linear or circular. Viruses also have segmented or complete genomes (Guttman, 2013; Murphy, 1988; O'Carroll and Rein, 2016) . As previously discussed, the PCR-based amplification starts with template DNA sample. In the case of RNA viruses, RNA is reverse transcribed to complementary DNA (cDNA), which becomes the starting material. The quality and purity of these biomacromolecules affect the efficiency of the amplification and quantification methods. The isolation and purification of DNA/RNA proceeds in these steps: lysis, purification, and recovery. Different types of DNA extraction methods include boiling, column method, magnetic beads, and use of FTA cards (Barbosa et al., 2016) . In the recent studies investigating presence of viruses in wastewater samples, commercially available DNA and RNA kits have been extensively used. The most common DNA extraction kits rely on the use of a column that has silica-based membranes (Barbosa et al., 2016) . The binding of DNA to silica in the presence of chaotropic salt sodium iodide (NaI) was first examined in the study of Vogelstein and Gillespie (1979) to extract DNA from agarose gel. Boom et al. (1990) also developed the method that made of use of silica, in the presence of the chaotropic agent guanidinium thiocyanate, to purify nucleic acids from human serum and urine. The column extraction method is classified as a solid phase-DNA extraction method. In this method, the sample undergoes lysis prior to column loading. Lysate is loaded to the column in the presence of chaotropic salts such as guanidine hydrochloride, guanidine isothiocyanate, sodium iodide, and sodium perchlorate. These salts allow the nucleic acids to selectively adsorb to the silica support, through disrupting their affinity to water. Purification comes after adsorption through washing with a reagent. The last step involves elution of the nucleic acids from the column using a buffer solution. (Barbosa et al., 2016; Butler, 2010) Examples of the kits with silica-based membranes that were used to extract viral nucleic acids from wastewater samples include QIAamp DNA Blood Mini Kit (Hamza et al., 2014) , QIAamp DNA Blood Maxi Extraction Kit (Jahne et al., 2020) , QIAamp Viral RNA Mini Kit Masclaux et al., 2013; Prado et al., 2019 Prado et al., , 2011 , Qiagen DNeasy Blood and Tissue kit , and AllPrep DNA/RNA Mini Kit (Symonds et al., 2014) . ). An advantage of using automatic extractors is their high throughput and lower variability of analytical results (Dundas et al., 2008) . There have been numerous studies on the detection of viruses in different water matrices, Table 3 . Samples were taken from influents, primary settling tanks, secondary and tertiary treatment effluents, and final effluents. Some of these studies examined the fate of viruses inside WWTPs by examining samples originating from secondary treatment steps (Ibrahim et al., 2017; Prado et al., 2019 Prado et al., , 2011 Symonds et al., 2014) . Other studies collected samples prior to and after tertiary treatment to determine its effectiveness in the context of the removal of viruses (Prado et al., 2011; Qiu et al., 2018) . Aside from the presence of viruses in wastewater, the occurrence of viruses in the sludges produced in the examined treatment J o u r n a l P r e -p r o o f 25 operations has been studied (Brown et al., 2015; Symonds et al., 2014; Wu and Liu, 2009 ). Few studies have investigated the presence and abundance of viruses in the ambient air from WWTPs (Brisebois et al., 2018; Masclaux et al., 2014; Pasalari et al., 2019) . As discussed, the sample processing methods affect the efficiency of subsequent detection methods. The choice of a specific method for detection or quantification also depends on the ease of cultivation of the viruses in laboratory conditions (Ibrahim et al., 2017) . Specific characteristics of the viruses affect the concentration and detection methods to be applied to the samples being examined. Wastewater and sludge samples have both a variety of DNA or RNA viruses (Bibby and Peccia, 2013; Ng et al., 2012) . Viruses are also classified according to their structures as enveloped and non-enveloped viruses. Non-enveloped viruses are characterized by the encapsulation of their nucleic acids by capsid proteins. Enveloped viruses have an additional lipid bilayer membrane that surrounds the capsid proteins (Lucas and Knipe, 2002; Ye et al., 2016a) . Disruption of the lipid bilayers by sample processing methods can lead to lower recoveries, affecting subsequent detection (Ye et al., 2016a) . This is of particular interest for investigations related to coronaviruses (CoVs) (Casanova et al., 2009; Geller et al., 2012; La Rosa et al., 2012; Wang et al., 2005b) . Methods for the detection and quantification of viruses found in wastewater include epifluorescence microscopy, transmission electronic microscopy, pulsed-field gel electrophoresis, immunofluorescence assay, flow cytometry, traditional cell-culture, and molecular methods. Main features of these methods are summarized in this section. It is noted that these detection methods provide different information regarding the presence of viruses in wastewater and sludge samples. As presented in the following discussions, some methods provide qualitative data and others quantitative data. Molecular methods for the J o u r n a l P r e -p r o o f 26 quantification of a virus are based on the determination of the number of selected segments of the genetic material of the virus. Thus, the virus can be detected even if inactivated, i.e. when the viral capsid or envelope is compromised, and even when the genetic material is fragmented. Cell-culture based methods and immunological methods are used for analysis of viability of viruses. Viruses are typically too small for detection using optical microscopy. Electron microscopy enables the inspection of these small particles (Laue, 2010) . One of the earliest methods used to quantify viruses is TEM, an imaging technique with nanometer-scale resolution. This method allows the quantification, and identification and classification of viruses according to morphology. (Roingeard et al., 2019) A basic methodology of TEM is negative staining. In negative staining, the virus particles are adsorbed on a pre-treated specimen support. After adsorption, the particles are stained with heavy metals, commonly uranyl acetate and phosphotungstic acid (PTA). After the staining and drying steps, the samples are analyzed under the electron microscope. Information from negative staining includes virus count, and virus sizes and structures. (Laue, 2010) Wu and Liu (2009) morphologies are known to be stable even after the mutation of their nucleic acids (Laue, 2010) . However, a limitation of the TEM is that it is highly selective to host-specific infectious virus, leading to a viral count result lower than the actual population (Brown et al., 2015) . The evaluation of very large number of samples using TEM is difficult since it requires the expertise of highly trained personnel and sophisticated equipment while TEM analyses cannot be automated at present (Barreto-Vieira and Barth, 2015). This virus quantification method makes use of highly fluorescent nucleic acid dyes (Wen et al., 2004) . Water samples are passed through a filter, commonly with a pore size of 0.22 μm (Otawa et al., 2007; Wu and Liu, 2009 ). The nucleic acids in the virus particles are then stained by a fluorescent dye. Staining with this type of dye allows the formation of fluorescent dots with dimensions larger than actual virus particles. The formation of fluorescent dots occurs when the fluorescent dye bound with nucleic acids are put under excitation. When the sample is viewed under an epifluorescence microscope, the fluorescent dots can be counted as the virus particles. (Ortmann and Suttle, 2009) One of the common dyes used in the recent relevant studies is SYBR Green I whose blue emission is observed using an epifluorescence microscope (Otawa et al., 2007) . Counting of viruses from influent, effluent, and sludge samples was done by Wu and Liu (2009) using epifluorescence microscopy with SYBR Green I. Otawa et al. (2007) also employed this direct count method, using SYBR Green I as staining agent, to enumerate viruses in mixed liquor activated sludge samples. J o u r n a l P r e -p r o o f 28 One advantage of this method is that the stained virus particles can be counted even at lower magnifications thus obviating the need to use TEM instrumentation (Ortmann and Suttle, 2009 ). Another advantage of EFM is that it can be used to count viruses that are not cultivable in laboratories. Aside from this, through the use DNase treatment, the EFM method can differentiate virus particles with nucleic acids from virus-like particles without nucleic acids. However, a limitation of this method is that it has a low efficiency in detecting RNA viruses or single-stranded DNA viruses. (Forterre et al., 2013) The combination of the use of fluorescent nucleic acid-specific dyes and flow cytometry has been applied for the quantification of viruses in wastewater samples. In FCM, samples containing viruses are diluted with buffer solutions and stained with fluorescent dyes. These samples are then injected into the flow cytometer. The hydrodynamics effect of the surrounding sheath fluid allows the virus particles to enter a stream in a single file. The individual particles intersect with a beam of monochromatic light, commonly from an argonion laser. The scattering and fluorescence produced by interactions of each particle with the incident laser beam is collected by detectors and analysed as the scatter and fluorescence intensity, respectively. (Brown & Wittwer, 2000) In the FCM approach, the samples are stained with a fluorescent dye, which binds selectively to DNA or RNA. The intensity of fluorescence of the DNA/dye and RNA/dye complexes is therefore correlated with the DNA/RNA content of the sample (Adan et al., 2017; Brown & Wittwer, 2000) . Advantages of FCM are its notably high accuracy and high speed of quantification (Ma et al., 2013) . J o u r n a l P r e -p r o o f 29 Ma et al. (2013) utilized FCM to determine the abundance of viruses in influent, primary and secondary settled water, activated sludge and effluent samples from a municipal wastewater plant. Comparing viral counts determined by FCM and EFM showed a higher sensitivity and higher speed of quantification using FCM. Brown et al. (2015) quantified viruses from activated sludge samples using FCM. In that study, the FCM method was shown to have a higher sensitivity than that of TEM by a factor of 2.7. The fluorescence-based analyses discussed in the preceding paragraphs can only be performed in the specialized laboratories. Pollard (2012) presented the conceptual design of a fluorescence instrument for in-situ and/or online monitoring of abundance of viruses in varying water matrices including effluent wastewater. The proposed portable instrument has an inline filter to remove bacteria from the water sample. A mixing coil is positioned after the filter where DNase and the fluorescent probe SYBR-Gold are added to the sample to form the DNA/RNA-SYBR viral complex. This mixture is directed to a reverse osmosis (RO) filter that concentrates the viruses. The RO concentrate, which contains stained viral particles, passes through a unit that measures the fluorescence signal. On the other hand, the permeate becomes the -background fluorescence‖, which is subtracted from the sample viral fluorescence. Although the proposed instrument is still at a conceptual stage, tests of this method showed that the EEM fluorescence intensity has a linear correlation (r 2 =0.97) with the viral count. One advantage of IFA over other quantification methods is that it can be used to analyse the infectivity of viruses . In this method, a sample from an infected cell culture J o u r n a l P r e -p r o o f 30 is adsorbed on a microscope slide. The viral protein antigen is detected by sequentially incubating the sample fixed on the slide with a specific antibody and a fluorescent chemicalconjugated secondary antibody that recognizes the former. Under optical excitation, the fluorophore-conjugated antibody fluoresces. When viewed under a fluorescent microscope, the antigen-antibody complex appears as a fluorescent particle. (Dowd et al., 2009; Im et al., 2019) This method was successfully used by Calgua et al. (2011) to quantify HAdV and JCPyV in raw sewage entering wastewater treatment plants. The reported results showed that the sensitivity of IFA is an order of magnitude higher than those of the other cell culture methods used in the study. The viability of the human adenovirus 2 (HAdV 2) found in activated sludge samples and effluent samples from a wastewater treatment plant was also verified by Schlindwein et al. (2010) using IFA. ELISA is a method that detects the presence of microbial antigens in various matrices (Boonham et al., 2014) . It relies on the principle of antigen binding to its specific antibody and eliciting a change in color or fluorescence due to the resultant enzyme activity. The first step of the process is the binding of antigen at a specific antibody immobilized on a surface, commonly in a set of 96-well microtiter plates. A second enzyme-linked antibody, specific for the same antigen, is utilized to form an antibody-antigen-antibody sandwich. The enzyme-coupled antibody reacts with a substrate that changes color when modified by the enzyme. The change in color or fluorescence is correlated with the concentration of the probed antigens in the sample. (Gan and Patel, 2013) J o u r n a l P r e -p r o o f 31 Kargar et al. (2013) utilized ELISA to detect RoV-A in influent and effluent samples of urban and hospital sewage disposal systems. This detection allowed determining the efficiencies of removal of RoV from urban and hospital wastewater treatment systems. The PFGE method makes use of a pulsating electric field to enable the separation of high molecular weight DNA fragments according to their molecular sizes (Nassonova, 2008 , Díez et al., 2000 . In this method, alternating electric fields generated between two separate electrodes cause the molecules to re-orient periodically to align to the imposed electric field (Le Tang et al., 2017) . The ability of DNA molecules to re-orient themselves and respond to the imposed modulated electric field depends on their molecular sizes and charges. It takes a shorter time for the smaller molecules to re-orient by migrating through the pores of a gel matrix towards the new anodes. On the other hand, larger DNA molecules take a longer time to re-orient. The larger DNA molecules that migrate slower than the set pulse time tend to migrate as one band through the gel Molecular methods for the detection and quantification of viruses are based on nucleic acid amplification. This section discusses the different methods of viral nucleic acid amplification, and subsequent detection and analysis. PCR is an amplification method which relies on the principle of cloning a DNA fragment from a DNA extract through in vitro replication (Kadri, 2020) . In the case of detection of viruses, this method amplifies or clones a fragment of the viral genome (Rodriguez et al., 2009) . A pair of oligonucleotides (primers), which define the starting site of DNA polymerase, is used to flank the DNA fragment that is to be replicated. Each of the oligonucleotide is designed to become attached to a certain edge of the DNA target, depending on its given sequence (Kadri, 2020) . Amplification through PCR makes use of an thermostable enzyme, commonly the Taq Polymerase, to synthesize new DNA strands from existing strands in the DNA extract (Lo and Allen, 2006) . PCR proceeds in three steps: denaturation or separation of double strands of DNA J o u r n a l P r e -p r o o f 33 at temperature >90 °C , annealing of primers at temperature close to their melting temperature (Tm) , and elongation at ≥72 °C (Kadri, 2020; Mackay, 2002) . Repeating these three steps produces multiple copies of DNA sequences (Lo and Allen, 2006) . Two-step PCR, which combines annealing and extension, has also been used leading to reduction of time of amplification (Girones et al., 1993; Jin et al., 2014) . After the amplification step, the PCR products are subjected to agarose gel electrophoresis (Mackay, 2002; Rodriguez et al., 2009) for their qualitative analysis. In the case of RNA viruses, the amplification of the nucleic acid starts with the production of DNA from RNA using a reverse transcriptase enzyme (Cobo, 2012) . In this method, the produced DNA is the cDNA which becomes the new template that is amplified using the PCR method described in 3.8.1. Reverse Transcription allows creating cDNAs from RNA viruses (Schinazi et al., 2013) . RNA viruses present in wastewater include, among many others, NoV, Aichi virus (AiV), parechovirus, HAV, hepatitis E virus (HEV), astrovirus, RoV and CoVs (Hellmér et al., 2014b) . RT-PCR was used by Monpoeho et al. (2000) to determine the abundance of EV in primary sludge, activated sludge and thickened sludge samples. The results showed that the largest viral concentration was present in the primary sludge samples. Smaller concentrations were found in the activated sludge samples, followed by the thickened sludge samples. RT-PCRs are conducted using random, oligo (dT) or specific primers (Newby et al., 2009; Rodriguez et al., 2009) . The use random primers will result in non-specific production of cDNA from the existing RNA array in the sample. Oligo (dT) primers hybridize the polyadenine tails in mRNAs (Jalali et al., 2017; Rodriguez et al., 2009 ). On the other hand, specific primers amplify a region of interest in the viral genome (Rodriguez et al., 2009) . The choice of primers affects the result of the amplification method. This is relevant to the detection of emerging viruses in wastewater. The qPCR is a method that allows simultaneous PCR amplification of nucleic acids and detection of the products (Cobo, 2012) . It is classified as a quantitative method because it allows quantification of the target sequences, in contrast to the conventional PCR method, which provides qualitative data through gel electrophoresis (Kadri, 2020) . Aside from providing quantitative data, qPCR also displays high sensitivity and is not affected by limiting concentrations of reagents (Watzinger et al., 2006) . In the qPCR method, PCR products are labelled by binding with fluorescent dyes or fluorogenic probes (Arya et al., 2005) . A Real-Time thermocycler is used to monitor the fluorescence J o u r n a l P r e -p r o o f 35 emission during the PCR amplification (Arya et al., 2005; Cobo, 2012) . The principle of quantification is based on the correlation between the intensity of fluorescence emission and the amount of amplification of the product of PCR after each cycle (Kadri, 2020) . RT-qPCR uses the same principle as qPCR except that it starts with RNA material instead of DNA, requiring a reverse transcription step (RT) prior to that of qPCR. Another advantage of the qPCR or RT-qPCR over the conventional method is that it eliminates the step of the agarose gel electrophoresis after the amplification step. Qiu et al. (2018) utilized qPCR to detect and quantify HAdV, JCPyV, and astrovirus in samples collected before and after UV treatment in a wastewater treatment plant. In the same study, RT-qPCR was used to detect and quantify NoV GII, reovirus, EV, RoV, and sapovirus. Prado et al. (2011) used qPCR and RT-qPCR to detect viruses in hospital wastewater effluents. The latter study demonstrated that the use of RT-qPCR in detecting NoV was more efficient than that of the conventional RT-PCR. This was attributed to the possibility of amplifying shorter fragments in RT-qPCR than was achieved in conventional RT-PCR. Kong et al., also reported that shorter PCR products, or amplicons, are generally amplified more effectively than long ones. However, this hypothesis contrasts with results of other studies, in which there were no sensitivity differences between conventional RT-PCR and RT-qPCR based on the length of the amplicons (Bastien et al., 2008) . Therefore, other factors could contribute to the variations, for instance the specificity of the primers, their accessibility to the region to be amplified, and the protocols used (Ferreira et al., 2009 ). In a study by Wong et al. (2010) , quantification by RT-qPCR showed no significant difference between enteric virus levels in dewatered sludge and sludge after mesophilic anaerobic digestion J o u r n a l P r e -p r o o f 36 treatment. This showed that anaerobic digestion may not be efficient for the inactivation of viruses in wastewater sludge. RT-qPCR was used to detect and quantify SARS-CoV-2 in wastewater samples of Massachusetts (F. . Results of these measurements gave a value of 1.04 10 3 genome copies per liter of sample. While additional WWTPs in other areas should be tested further, the results showed that RT-qPCR data from wastewater samples could be used to estimate the viral burden in the affected population. RT-qPCR was also applied to detect and quantify SARS-CoV-2 in raw wastewater samples of Paris, France (Wurtzer et al., 2020) . Although the infectivity of the viruses in the examined samples was not yet ascertained by this method, these RT-qPCR results are highly important because they can be interpreted to indicate that contamination of the wastewaters in Paris had existed even before the onset of the rapid increase of the Coronavirus disease 2019 (COVID-19) cases in the affected population. These studies demonstrate the potential role of RT-qPCR in the development of the Wastewater Based Epidemiology (WBE) approach that can be applied to investigate viral disease outbreaks in communities (Ahmed et al., 2020; Xagoraraki et al., 2014) . It should be noted that a limitation of the qPCR and RT-qPCR methods, as in the conventional PCR and RT-PCR, is that they detect both infectious and non-infectious viruses. Still, the data of these methods are useful in evaluating the efficiency of disinfection treatments, since they detect viruses that cannot be effectively detected in cell culture-based methods. These PCR-based methods may be used to detect viruses, such as RoV and NoV, that are difficult to propagate in cell cultures. J o u r n a l P r e -p r o o f 37 Recently, combined azo dye pre-treatment and qPCR has been applied even for the quantification of damaged viruses, overcoming the difficulties associated to the culturing of some viruses for the determination of the viability (Leifels et al., 2020) . Multiplex PCR allows simultaneous detection of different viruses present in a single sample using more than one set of primers in one reaction (Newby et al., 2009) . Multiplex qPCR also allows detection of different specific viruses using more than one fluorescent reporter (Haramoto et al., 2018) . Hamza et al. (2014) used Luminex assay, a novel multiplex PCR-based assay, to simultaneously detect human enteric viruses present in wastewater influents. This approach makes use of the Luminex XMap technology with microspheres that are uniquely labelled with variable amounts of 2-3 different fluorophores to obtain up to 500 spectrally distinct microsphere sets. In this method oligonucleotide probes specific for desired DNA sequences are coupled to the beads and the PCR products obtained using biotin-labeled primers are hybridized with probes. Addition of phycoerytrin-streptovidin complex that interacts with biotinylated sequences allows detecting the presence of amplicons on the beads by fluorescence emission. The microspheres enter an analyzer that makes use of the principle of flow cytometry. The beads are identified after they pass through lasers of different wavelengths and the spectral response from each bead is associated with a single oligonucleotide probe. The Luminex analyzer also measures the fluorescence emitted by the phycoerythrin to quantify the amount of bound nucleic acids. (Dunbar & Hoffmeyer, 2013; Hamza et al., 2014) J o u r n a l P r e -p r o o f 38 The results reported in Hamza et al. (2014) showed that the multiplex assay was as sensitive as qPCR in the detection of several enteric viruses in wastewater samples. Di Bonito et al. (2017) also successfully used the multiplex PCR bead-based technology (Luminex) to detect oncogenic viruses in untreated wastewater. This class of viruses, that are related to human cancer, include mucosal and cutaneous human papillomavirus (HPV), human polyomavirus (HPyV), human herpesvirus (HHV) and mouse mammary tumor virus (MMTV). The multiplex qPCR has been shown to have a similar sensitivity to singleplex PCR in the detection of RoV-A in raw sewage samples (Fumian, Leite et al., 2010) . Aside from the multiplex assay's sensitivity, another advantage of this method is its speed associated with the simultaneous detection principle that it employs. It also requires lower reagent cost and labor compared to singleplex PCR-based assays. (Dunbar & Hoffmeyer, 2013; Fumian et al., 2010; Hamza et al., 2014) Aside from quantification, PCR products may also be subjected to DNA sequencing. DNA sequencing is the process of determining the specific order of nucleotides for a segment of DNA (Artika et al., 2020) . The most common sequencing method is based on the dideoxy or chain-termination method, or the Sanger method (Clark et al., 2019; Hoy, 2019) . In this method, DNA polymerase randomly produces multiple partial copies of the DNA template that have varying lengths. The lengths of each subset DNA copies differ by one nucleotide, resulting to each copy ending in a different Sequencing analyses showed that the three wastewater treatment plants had similar distribution of types of HAdV, HPV and HEV types despite the differences in the location, and volume of wastewater treated. America were tested using DNA sequencing to assess infectious risks related to reuse of sludge as agricultural soil amendment (Bibby and Peccia, 2013) . NGS showed that aside from the viruses normally associated with gastrointestinal infection, the examined sludge samples had an abundance of viruses associated with respiratory diseases. These viruses include HAdV Types B and C, Bocavirus, and Coronavirus HKU1, which may be transmitted by airborne route (droplet spread) or by fomites. This poses an additional concern since aerosols are known to be released The latter studies show the role of sequencing analysis in the ongoing effort to identify the diversity of strains of viruses in wastewater and wastewater sludge samples. The use of this approach to monitor wastewater systems may serve as an early warning method to detect possible disease outbreaks (Hellmér et al., 2014b) and as a tool for public health surveillance (Fernandez-Cassi et al., 2018) . It may also be used as a basis for re-evaluation of regulatory requirements related to pathogens in wastewater systems (Bibby and Peccia, 2013; Montazeri et al., 2015) . 3.8.4.1 Cell Culture. Traditional cell culture methods use cytopathic effects (CPE) for measuring infectious viruses . In this approach, cells are cultivated under controlled conditions and infected with viruses, which need host cells to replicate. The identification of presence of viruses is observed through CPEs that are visible under light microscopy. CPEs are manifested as deterioration of monolayer cells that have been infected by a virus. (Dilnessa and Zeleke, 2017) The observed CPEs and the rates of CPE appearance are used to identify viruses. Destruction of the monolayer cell, in which the infected cells shrink easily and detach from the glass, is typically associated to EV. Focal degeneration of infected cells is typical of herpesviruses. J o u r n a l P r e -p r o o f 43 Enlargement and formation of grape-like clusters are associated with HAdV. The appearance of altered areas, referred to as inclusion bodies, in stained cells is also a characteristic type of cytopathic effects observed for HAdV and herpesviruses. (Suchman and Blair, 2007) Aside from the long period needed to obtain results, another limitation of the traditional cell culture is that some viruses do not grow in cell cultures (Dilnessa and Zeleke, 2017; Reynolds, 2004) . Another complication is that some viruses such as RoV and HAV do not give visible cytopathogenic results and are therefore not detected by conventional cell culture method. It is also not a highly specific method since multiple types of viruses can be supported by a single cell line. (Reynolds, 2004) 3.8.4.2 ICC-PCR. The combination of cell culture and PCR was developed to address the limitations of each method when used individually (Rodriguez et al., 2009 ). In the ICC-PCR method, the samples with viruses are introduced to cell culture media and incubated for 2-3 days. Samples of cell culture with viruses are subjected to freezing, which causes lysis of the cells. The virus particles are released from their host cells when lysis occurs. After this, PCR-based amplification is applied to the lysate. (Newby et al., 2009) The approach of integrated cell culture-real time PCR (ICC-qPCR) was used by Qiu et al. (2018) to evaluate the efficiency of UV disinfection in a wastewater treatment plant. The results showed that the ICC-qPCR method was more efficient than qPCR in detecting reovirus. This study also demonstrated that RoV was rarely detected by the ICC-qPCR method. This was attributed to the insufficient rate of RoV propagation in cell culture in the study. The viability of HAdV in raw sewage, secondary effluent, and reclaimed water was assessed by Prado et al. (2019) using ICC-qPCR. Using this method showed that a significant amount of HAdV was viable even after undergoing the activated sludge wastewater treatment. Integrated cell culture-real time RT-PCR (ICC-RT-qPCR) was shown to be more efficient than traditional plaque assay in detecting the presence of mammalian orthoreovirus in raw and treated sludge samples (Gallagher and Margolin, 2007) . The latter studies showed that in terms of virus inactivation, the ICC-PCR method is useful in assessing the efficiency of different stages of wastewater treatment in virus removal. However, ICC-PCR has its limitations such as the non-detection of some viruses that are not cultivable in cell culture. It should also be noted that it is designed to detect specific types of viruses depending on the PCR primers used. It is also therefore prone to false negatives in the detection of other viruses present in the sample. Because of this, some studies still use the traditional cell culture along with ICC-PCR . The efficiency of the methods used to concentrate, detect and quantify viruses is monitored through process controls (Blanco Fernández et al., 2017; Hennechart-Collette et al., 2015) . Process control viruses are either added to samples prior to their concentration, to concentrated samples prior to nucleic acid extraction, or to nucleic acid extracts prior to the amplification and detection (Haramoto et al., 2018) . The chosen process control viruses must have similar morphology as the target viruses, must not be naturally found in the samples and must be easily J o u r n a l P r e -p r o o f 45 quantified by nucleic acid-based assays and infectivity assays (Blanco Fernández et al., 2017; Diez-Valcarce et al., 2011) . Murine norovirus has been used as a process control for NoV because of the former's similarity in the morphology and genetic structure to the target virus (Hennechart-Collette et al., 2015) . Murine norovirus was used by Kitajima et al. (2014) as a process control virus to determine the efficiencies of viral nucleic acid extraction and RT-qPCR in a study on the detection and quantification of viruses, including NoVs, in wastewater. and was utilized as a process control to asses viral RNA extraction and PCR efficiencies in a study on the detection of HAV from WWTPs (Ouardani et al., 2016) . However, the study of Petterson et al. (2015) showed that there is a low correlation between the recoveries of spiked mengovirus, and the enteric viruses HAdV, NoV GI, and NoV GII from surface water samples. This result indicated that there is a need for further exploration of process control viruses that would be as close as possible to the structure and behavior of the target viruses. CoVs are enveloped single-stranded RNA viruses with sizes ranging from 60 to 220 nm. The viral protein capsid is covered by a lipid bilayer membrane that contains proteins or glycoproteins and crown-like spikes on the surface. Contrarily to -simple‖ non-enveloped RNA viruses, CoVs are less stable in wastewater. SARS-CoV-1 has been shown to persist up to 2 days at room temperature, both in domestic and hospital sewages, and more than 14 days at 4°C (Wang et al., 2005b (Wang et al., , 2005c . These considerations pertinent to the stability of CoVs, should be taken into account during the sampling and storage of wastewater samples, as well as during the treatment of wastewater for the detection, quantification and particularly in the determination of the viability of these viruses. Methods for concentration of CoVs in water media were recently examined by La Rosa et al. (2020) . Enveloped viruses such as CoVs are sensitive to pH variations, with their optimal stability at slight acidic pH of 6-6.5 (Sattar et al., 2009) (Collomb et al., 1986) , SARS-CoV-1 (Wang et al., 2005a) , murine hepatitis virus (MHV) (Ye et al., 2016b) , bovine CoV (Abd-Elmaksoud et al., 2014) , and transmissible gastroenteritis virus (TGEV) (Blanco et al., 2019) . Adsorption on glass wool and glass powder (Abd-Elmaksoud et al., 2014; Blanco et al., 2019; Collomb et al., 1986) or on silica gel compounded with aluminum hydroxide (Wang et al., 2005a) , followed by elution with neutral (Wang et al., 2005a) or alkaline (Abd-Elmaksoud et al., 2014; Blanco et al., 2019; Collomb et al., 1986) buffers were some of the techniques adopted for the concentration of the above mentioned CoVs. PEG precipitation, ultracentrifugation and ultrafiltration were compared by Ye et al. (2016b) Table 4 . Most of those studies have been published as pre-print articles and not yet subjected to peer-review process at the moment of writing of this review. Therefore, the information reported in these publications should be considered with caution. In absence of a general protocol for recovery of CoVs and of SARS-CoV-2 from wastewater, different procedures of sampling, sample storage and concentration, and virus detection have been applied (Tables 4 and 5 ). Currently, scarce information is available on the efficiency of recovery of SARS-CoV-2 from wastewater. This requires investigations on the determination of the concentration of SARS-J o u r n a l P r e -p r o o f 48 CoV-2 in wastewater model samples spiked with a known number of virus copies. As most of the existing concentration methods have been used to recover non-enveloped human enteric viruses, further research must be conducted to evaluate the efficiency of existing concentration methods in recovering enveloped viruses, such as the SARS-CoV-2 (Ahmed et al., 2020) . As previously discussed, enveloped viruses have a structure that is different from non-enveloped viruses. Enveloped viruses tend to be sensitive to some organic solvents used in concentration methods (La Rosa et al., 2020; Ye et al., 2016a) . A related study by Ye et al. (2016) compared recovery efficiencies of different methods used to concentrate enveloped viruses from wastewater. The latter study showed that using ultracentrifugation at 100 000 for an hour resulted in lower recoveries of murine hepatitis virus (MHV) and Pseudomonas phage (φ6). The lower recovery efficiencies were attributed to the strong centrifugal forces that may have disrupted the lipid bilayer membranes of the enveloped viruses. In the same study, an optimized ultrafiltration method, with a pre-filtration step using a 0.22 μm filter, resulted in relatively higher recoveries of enveloped viruses. On the other hand, PEG precipitation showed low recoveries of the model enveloped viruses. Percentage recoveries of SARS-CoV-2 have not been determined due to handling and facility restrictions related to biosafety (Ahmed et al., 2020) . Further studies need to be carried out to determine the efficiencies of alternative concentration methods applicable to recover SARS-CoV-2 viruses from wastewater and in sludge samples. Control experiments on the efficiency of recovery of viruses, from SARS-CoV-2 infected wastewater, were performed by determining the concentration of F-specific RNA phages according to ISO 10705 (Medema et al., 2020) , or by spiking mengovirus vMC0 (University of Valencia, Spanish Type Culture Collection, CECT 100000) in wastewater samples according to ISO 15216-2:2017 (Randazzo et al., 2020 . Haramoto et al., (2020) utilized the electronegative membrane-vortex method to concentrate SARS-CoV-2 from wastewater samples and evaluated the efficiency of recovery using pepper mild mottle virus (PMMV). Medema et al. (2020) suggested the spiking of other human CoVs, such as CoV 229E, to the sewage samples as a reliable internal standard for the determination of the efficiency of recovery of CoVs from wastewater. SARS-CoV-1 is most proximal to the novel SARS-CoV-2, among the viruses investigated in wastewater. Wang et al. (2005a) reported an average SARS-CoV-1 recovery efficiency of 1% by applying adsorption of virus on silica gel compounded with aluminum hydroxide and elution with a buffer at pH of 7.4. Modes of sampling and sample storage can affect the detection and viability of CoVs in wastewater. As discussed, SARS-CoV-1 infectivity persisted in municipal and hospital wastewater for 2 days at room temperature and for more than 14 days at 4°C. On the other hand, to the best of the authors' knowledge, information is lacking on the effect of freezing on viability and efficiency of recovery of CoVs from wastewater. Composite and grab samples from WWTPs were analyzed for detection of SARS-CoV-2 (Table 4 ). In some investigations, debris and particulate were removed by centrifugation or filtration or by a combination of these techniques prior to concentration of the wastewater samples. The nature of these treatments can affect the final virus concentration since CoVs tend to be adsorbed onto organic matter and can even be protected by suspended solids (Gundy et al., 2008) . For safe handling of samples, pasteurization at 57 or 60 °C can be applied for inactivation of viruses and other pathogens present in wastewater (La Rosa et al., 2020; F. Wu et al., 2020) . Several techniques for secondary concentration of the water sample, or combination of them, were used, including: i) centrifugal filtration (Ahmed et al., 2020; Bar Or et al., 2020; Medema et al., 2020; F. Wu et al., 2020) , ii) ultracentrifugation (Wurtzer et al., 2020) , iii) precipitation with PEG (Bar Or et al., 2020; La J o u r n a l P r e -p r o o f 50 Rosa et al., 2020; F. Wu et al., 2020; Zhang et al., 2020) , aluminum chloride (Randazzo et al., 2020) or alum (Bar Or et al., 2020) ; iv) electronegative membrane filtration (Ahmed et al., 2020; Haramoto et al., 2020) . The investigations on SARS-CoV-2 in wastewater and WWTPs exploit the methodological principles applied to other pathogenic and non-pathogenic viruses, applying some modifications necessary for adaption to the characteristics of this new strain of coronavirus. Here, we briefly describe the molecular materials and procedures adopted so far by different authors for the study of SARS-CoV-2 in wastewater samples. Table 5 The effect of these sample processing steps to the viability of the viruses was also examined. Ahmed et al. (2020) extracted RNA, using the RNeasy PowerWater Kit and RNeasy PowerMicrobiome Kit (Qiagen), from the ultra-filtered sample or from the electronegative membrane. For specific detection and quantification, RT-qPCR was used with the primers N_Sarbeco and NIID_2019-nCOV_N, both of which are specific for the nucleocapsid protein gene. One-step kit RT-qPCR was adopted, where reverse transcription and qPCR occurred in the same reaction well. La Rosa et al. (2020) assessed the presence of SARS-CoV-2 in Italian WWTP by means of RT-PCR, using two groups of specific primers for SARS-CoV-2: a newly developed set targeting ORF1ab (La Rosa et al., 2020) and a published set, designed for the pharyngeal swab, specific for the spike (S) protein gene. In this study, broad-range primers, which were designed before the detection of the new strain of coronavirus, were also tested, amplifying a conserved region of the ORF1ab of Coronavirinae members. However, these primers did not give specific signals due to some nucleotide differences in this region found with subsequent sequencing of SARS-CoV-2. Wurtzer et al. (2020) investigated the presence of viruses in wastewater samples collected from 3 major WWTPs in Paris, using the RT-qPCR with primers targeting the envelope protein gene (E) and RNA-dependent RNA polymerase gene (RdRP). After concentration by ultracentrifugation, the viral genome was extracted using an optimized protocol from the commercial PowerFecal Pro kit on a QIAsymphony extractor (Qiagen). RNA extraction was carried out via the commercially RNeasy mini kit (Qiagen). Nemudryi et al. (2020) also evaluated the phylogenetic relationship of the isolated SARS-CoV-2 genome with the other sequenced worldwide, using 10 published primer pairs (Table 5) to amplify with nonquantitative RT-PCR and sequence some polymorphic regions dispersed in the genome. F. preliminarily detected the presence of SARS-CoV-2 in PEG-precipitated wastewater samples from a WWTP of Massachusetts (USA) with classical PCR and published primers directed towards the (S) protein gene spike. After detection, RT-qPCR was used to quantify the viral titer, with primers targeting N1, N2 and N3 loci of the nucleocapsid protein gene (N) and published by US, CDC. Viral RNA was extracted with Trizol (Thermofisher). The concentration of SARS-CoV-2 in raw wastewater obtained by recent studies varies from 10 1 to 10 6 genome copies /L ( Table 4 ). Concentrations of SARS-CoV-2 in secondary effluent range from 10 3 to 10 5 genome copies/L (Haramoto et al., 2020; Randazzo et al., 2020) . SARS-CoV-2 was also present at a concentration of 10 3 to 10 4 genome copies/L in the effluent from the septic tanks of Fangcang hospital in Wuhan, Hubei, China . The obtained concentration of the virus in primary sludge samples is 10 4 to 10 8 genome copies/L (Alpaslan Kocamemi et al., 2020; Peccia et al., 2020) . This concentration in primary sludge samples is slightly higher than that in the wastewater samples. These results are in accordance with the tendency of enveloped viruses to adsorb to the solid-fraction of wastewater (Ye et al., 2016a) , resulting to their accumulation in the wastewater sludge. This is important in the study of the emerging viruses, such as SARS-CoV-2, since the concentrated sludge sample can provide information on the viruses present in wastewater and in corresponding affected communities. Rimoldi et al. (2020) performed the same viability test of SARS-CoV-2 in municipal wastewater samples, in which no viable virus was also detected. The study revealed that SARS-CoV-2 genomes were not detected in the influent of a hospital septic tank (after primary disinfection tank) but were detected in the effluent at a concentration of 0.50 10 3 to 1.87 10 4 genome copies/L after disinfection with sodium hypochlorite. The viral genomes in the septic tank effluent were detected when the free chlorine concentration has declined to non-detectable level. The absence in the influent and presence in the effluent suggested the release of embedded viruses in the stool particles, which provided protection from the treatment process. Although the latter study did not perform a viability analysis, the results indicate the need for further studies to confirm that the sewage or wastewater treatment systems are not SARS-CoV-2 transmission pathways. A limited number of studies have shown that wastewater systems emit bioaerosols that have significant concentrations of viruses such as RoV, NoV, HAdV, HAV, and Herpes Simplex Virus Type 1 (HSV1) (Brisebois et al., 2018; Masclaux et al., 2014; Pasalari et al., 2019) . J o u r n a l P r e -p r o o f 54 Viruses in aerosols pose a risk to the WWTP or sewage workers who are exposed to these viruses via the inhalation or contamination by contact with deposited aerosols on surfaces (Masclaux et al., 2014) . Highly resistant viruses, such as RoV and NoV, that are present in the local atmosphere of a WWTP can also pose risks to the residents living near the facility (Pasalari et al., 2019) . Although no evidence has so far emerged concerning the emission of SARS-CoV-2 to the ambient air at WWTPs or sewage systems, future studies on this potential exposure pathway need to be conducted to assess possible risks to workers and affected residents. The study of van Doremalen et al. (2020) examined the stability of SARS-CoV-2 in aerosols. Although the experimental condition used in that study had only a 3 hours duration, it showed that SARS-CoV-2 remained viable in aerosols. The study also compared the viability of SARS-CoV-2 and SARS-CoV-1 in aerosols. It showed that both viruses have similar stabilities. SARS-CoV-1 virus was previously reported to be transmitted through aerosols in sewage systems of a residential building in Hong Kong, leading to a disease outbreak in the examined area (Chim et al., 2003; Hung, 2003) . Regulations related to wastewater treatment do not commonly require routine monitoring of viruses before wastewater discharge to receiving bodies of water. However, several studies have shown that pathogenic viruses remain abundant in wastewater and sludge even after treatment. Monitoring of viruses is not widely conducted in wastewater treatment plants because of the cost, time and complexity involved in conducting detection methods. The need for rapid, highly accurate, and sensitive methods at optimum cost arises. The possibility of use of in situ monitoring tools is to be further explored in this context. The use of biosensors to detect viruses in environmental samples has been previously studied but there is only a limited number of studies on application of this approach to detect viruses in wastewater. Chung et al. (2019) utilized a microfluidic paper analytic device (μPAD) to detect NoV in environmental water samples including reclaimed wastewater. In the latter study, NoV viruses were detected without prior sample concentration and nucleic acid amplifications. The NoV were captured by the μPAD, where antibody-conjugated fluorescent submicron particles were also added. The use of μPAD relies on the correlation between the virus concentration and the number of aggregated particles formed by antibody-antigen binding. Additional visualization methods were developed in the latter study to make the detection method suitable to field applications. The quantity of NoV in the samples was determined using a smart-phone fluorescence microscope and a mobile graphical user interface (GUI) application. However, this method can only be used to detect specific viruses whose detection depends on the antibody used. The use of biosensors such as μPAD is a potential tool for rapid in detection of viruses in environmental water samples such as wastewater and is still in the nascent stage. Along with the molecular detection methods, tools such as paper-based devices for rapid, in situ, and sensitive detection can possibly provide timely information about the circulation of emerging pathogenic viruses such as SARS-CoV-2 in wastewater and in affected communities (Mao et al., 2020) . Journal Pre-proof J o u r n a l P r e -p r o o f 56 There is a wide range of detection and quantification methods that have been used to detect and quantify viruses in wastewater and sludge samples. Molecular methods have been extensively used in the recent studies for specific and sensitive detection of viruses in wastewater. However, it is notable that there are instances when the use of at least two detection methods proved helpful in monitoring the abundance and diversity of viruses in wastewater and sludge. This is to ensure that wider range of viruses found in samples are detected and quantified. Analysis of viability of viruses is also needed for a complete information regarding their occurrence in wastewater and sludge samples. Pre-treatment methods must be chosen according to the characteristics of the wastewater or sludge sample matrices. In applying these techniques, methods to reduce effects of inhibitors that are originally present in the wastewater or sludge samples, or in the reagents must be considered. Recent developments that resulted in increasing efficiency of detection of viruses in sludge samples focused on their release from the highly aggregated sludge matrix. Addition of optimized ultrasonication step to the traditional adsorption-elution method, and the use of dispersants and enzymes to break down sludge flocs are the current developments in the sludge sample processing methods. High-throughput sequencing has been used in the comprehensive studies of wastewater treatment systems, allowing for a large number of samples to be processed simultaneously. This approach has been shown to be important in studying the fate of viruses during and after wastewater and sludge treatment processes, in evaluating efficiencies of the treatment systems, and in identifying paths of transmission of human diseases through exposure to wastewater or sludge. Recent studies have illustrated the importance of data of molecular methods for studying the previous, ongoing and possible disease outbreaks. Detection and quantification methods J o u r n a l P r e -p r o o f 57 developed to ascertain the occurrence and identities of viruses in wastewater clearly play an important role in using the WBE approach in studying the circulation of infectious viruses such as SARS-CoV-2 in exposed communities. Research needs identified in this review include further validation of the processing methods for wastewater samples, with a specific focus on ascertaining concentrations of emerging viruses such as SARS-CoV-2 using seeded samples. Further validation of assays that use primers specific to SARS-CoV-2 in wastewater matrices should also be conducted. Further studies should also include SARS-CoV-2 infectivity assays of influent, effluent and sludge samples. Teixeira, P., Costa, S., Brown, B., Silva, S., Rodrigues, R., Valério, E., 2020 Thongprachum, A., Fujimoto, T., Takanashi, S., Saito, H., Okitsu, S., Shimizu, H., Khamrin, P., Maneekarn, N., Hayakawa, S., Ushijima, H., 2018 . Detection of nineteen enteric viruses in raw sewage in Japan. Infection, Genetics and Evolution 63, 17-23. https://doi.org/10.1016 /j.meegid.2018 .05.006 van Doremalen, N., Bushmaker, T., Morris, D.H., Holbrook, M.G., Gamble, A., Williamson, B.N., Tamin, A., Harcourt, J.L., Thornburg, N.J., Gerber, S.I., Lloyd-Smith, J.O., de Wit, E., Munster, V.J., 2020 Journal Pre-proof Simultaneous Concentration of Bovine Viruses and Agricultural Zoonotic Bacteria from Water Using Sodocalcic Glass Wool Filters Flow cytometry: basic principles and applications Viromic Analysis of Wastewater Input to a River Catchment Reveals a Diverse Assemblage of RNA Viruses First confirmed detection of SARS-CoV-2 in untreated wastewater in Australia: A proof of concept for the wastewater surveillance of COVID-19 in the community Comparison of Concentration Methods for Quantitative Detection of Sewage-Associated Viral Markers in Environmental Waters Metagenomicsbased analysis of viral communities in dairy lagoon wastewater SARS-CoV-2 Detection in Istanbul Wastewater Treatment Plant Sludges (preprint) Recovery Comparison of Two Virus Concentration Methods from Wastewater Using Cell Culture and Real-Time PCR Sludge utilisation in agriculture: possibilities and prospects in Greece Pathogenic viruses: Molecular detection and characterization. Infection Basic principles of real-time quantitative PCR Adenovirus and rotavirus recovery from a treated effluent through an optimized skimmed-milk flocculation method Mechanism of Precipitation of Proteins by Polyethylene Glycols Regressing SARS-CoV-2 sewage measurements onto COVID-19 burden in the population: a proof-ofconcept for quantitative environmental surveillance DNA extraction: finding the most suitable method An environmental and health perspective for COVID-19 outbreak: Meteorology and air quality influence, sewage epidemiology indicator, hospitals disinfection, drug therapies and recommendations Negative and Positive Staining in Transmission Electron Microscopy for Virus Diagnosis Quantitative Real-Time PCR Is Not More Sensitive than -Conventional‖ PCR Wavelength Dependent UV Inactivation and DNA Damage of Adenovirus as Measured by Cell Culture Infectivity and Long Range Quantitative PCR Identification of Viral Pathogen Diversity in Sewage Sludge by Metagenome Analysis Enteric Viruses Glass Wool Concentration Optimization for the Detection of Enveloped and Non-enveloped Waterborne Viruses Comparison of internal process control viruses for detection of food and waterborne viruses Recent trends on methods for the concentration of viruses from water samples Rapid and simple method for purification of nucleic acids Methods in virus diagnostics: From ELISA to next generation sequencing Human viral pathogens are pervasive in wastewater treatment center aerosols Quantitative Microbial Risk Assessment and Infectious Disease Transmission Modeling of Waterborne Enteric Pathogens Flow cytometric quantification of viruses in activated sludge DNA Extraction.pdf Detection and quantitation of infectious human adenoviruses and JC polyomaviruses in water by immunofluorescence assay UVC Inactivation of dsDNA and ssRNA Viruses in Water: UV Fluences and a qPCR-Based Approach to Evaluate Decay on Viral Infectivity Development and application of a one-step low cost procedure to concentrateviruses from seawater samples New methods for the concentration of viruses from urban sewage usingquantitative PCR Ferrihydrite treatment to mitigate inhibition of RT-qPCR virus detection from largevolume environmental water samples Viral Removal by Wastewater Treatment: Monitoring of Indicators and Pathogens Survival of surrogate coronaviruses in water Methods for primary concentration of viruses from water samples: a review and meta-analysis of recent studies A familial cluster of pneumonia associated with the 2019 novel coronavirus indicating person-to-person transmission: a study of a family cluster Mechanisms of Pathogenic Virus Removal in a Full-Scale Membrane Bioreactor Genomic characterisation of the severe acute respiratory syndrome coronavirus of Amoy Gardens outbreak in Hong Kong Rapid Detection of Sewage Sample Polioviruses by Integrated Cell Culture Polymerase Chain Reaction Smartphone-Based Paper Microfluidic Particulometry of Norovirus from Environmental Water Samples at the Single Copy Level Molecular Biology Application of Molecular Diagnostic Techniques for Viral Testing Research on coronaviruses in water. I. Adsorption and elution of the coronavirus on glass powder Human and bovine viruses in the Milwaukee River watershed: Hydrologically relevant representation and relations with environmental variables A comparative study of digital RT-PCR and RT-qPCR for quantification of Hepatitis A virus and Norovirus in lettuce and water samples New Molecular Methods for Detection of Waterborne Pathogens Detection of oncogenic viruses in water environments by a Luminexbased multiplex platform for high throughput screening of infectious agents High prevalence of hepatitis E virus in raw sewage in Southern Italy Estimating the concentration of viral pathogens and indicator organisms in the final effluent of wastewater treatment processes using stochastic modelling Pulsedfield gel electrophoresis analysis of virus assemblages present in a hypersaline environment Analytical Application of a Sample Process Control in Detection of Foodborne Viruses Cell Culture, Cytopathic Effect and Immunofluorescence Diagnosis of Viral Infection Is SARS-CoV-2 Also an Enteric Pathogen with Potential Fecal-Oral Transmission: A COVID-19 Virological and Clinical Review Environmental Microbiology Microsphere-Based Multiplex Immunoassays: Development and Applications Using Luminex® xMAP® Technolog Comparison of Automated Nucleic Acid Extraction Methods with Manual Extraction Confirming the need for virus disinfection in municipal subsurface drinking water supplies Evaluation of Secondary Concentration Methods for Poliovirus Detection in Wastewater Two-Step Concentration of Complex Water Samples for the Detection of Viruses Metagenomics for the study of viruses in urban sewage as a tool for public health surveillance Environmental dissemination of group A rotavirus: P-type, G-type and subgroup characterization Molecular Assays for Targeting Human and Bovine Enteric Viruses in Coastal Waters and Their Application for Library-Independent Source Tracking Fake virus particles generated by fluorescence microscopy Detection of norovirus epidemic genotypes in raw sewage using next generation sequencing Detection of rotavirus A in sewage samples using multiplex qPCR and an evaluation of the ultracentrifugation and adsorption-elution methods for virus concentration Development of an integrated cell culture-Real-time RT-PCR assay for detection of reovirus in biosolids Enzyme Immunoassay and Enzyme-Linked Immunosorbent Assay Human Coronaviruses: Insights into Environmental Resistance and Its Influence on the Development of New Antiseptic Strategies Assessment of Enteric Pathogen Shedding by Bathers during Recreational Activity and its Impact on Water Quality How much reduction of virus is needed for recycled water: A continuous changing need for assessment? Application of PCR to the Detection of Adenoviruses in Polluted Waters Viradel method for detection of rota virus from seawater Rotavirus detection in environmental water samples by tangential flow ultrafiltration and RT-nested PCR General considerations on sludge disposal, industrial and municipal sludge, in: Industrial and Municipal Sludge Survival of Coronaviruses in Water and Wastewater An integrated cell absorption process and quantitative PCR assay for the detection of the infectious virus in water Virus, in: Brenner's Encyclopedia of Genetics Detection of human viruses in rivers of a densly-populated area in Germany using a virus adsorption elution method optimized for PCR analyses Development of a Luminex assay for the simultaneous detection of human enteric viruses in sewage and river water Recovery of human norovirus from water by virus concentration methods A review on recent progress in the detection methods and prevalence of human enteric viruses in water First environmental surveillance for the presence of SARS-CoV-2 RNA in wastewater and river water in Japan Ultraviolet inactivation of selected bacteria and viruses with photoreactivation of the bacteria Validation of Internal Controls for Extraction and Amplification of Nucleic Acids from Enteric Viruses in Water Samples Effects of rainfall events on the occurrence and detection efficiency of viruses in river water impacted by combined sewer overflows Distribution of viruses associated with particles in waste water Detection of Pathogenic Viruses in Sewage Provided Early Warnings of Hepatitis A Virus and Norovirus Outbreaks Detection of Pathogenic Viruses in Sewage Provided Early Warnings of Hepatitis A Virus and Norovirus Outbreaks Determination of which virus to use as a process control when testing for the presence of hepatitis A virus and norovirus in food and water Comparison of Hollow-Fiber Ultrafiltration to the USEPA VIRADEL Technique and USEPA Method 1623 Evaluation of Methods for the Concentration and Extraction of Viruses from Sewage in the Context of Metagenomic Sequencing DNA Sequencing and the Evolution of the --Omics,‖ in: Insect Molecular Genetics Methods for Detection of Viruses in Water and Wastewater The SARS epidemic in Hong Kong: what lessons have we learned? Detection of Aichi virus genotype B in two lines of wastewater treatment processes An Introduction to Performing Immunofluorescence Staining Droplet digital PCR quantification of norovirus and adenovirus in decentralized wastewater and graywater collections: Implications for onsite reuse The Polymerase Chain Reaction, in: Basic Science Methods for Clinical Researchers Evaluation of a portable nanopore-based sequencer for detection of viruses in water Differences of PCR efficiency between two-step PCR and standard three-step PCR protocols in short tandem repeat amplification Synthetic Biology -New Interdisciplinary Science. IntechOpen First molecular detection of group A rotavirus in urban and hospital sewage systems by nested-RT PCR in Shiraz, Iran New Electropositive Filter for Concentrating Enteroviruses and Noroviruses from Large Volumes of Water Development of a Virus Concentration Method and Its Application to Detection of Enterovirus and Norwalk Virus from Coastal Seawater Detection and isolation of H5N1 influenza virus from large volumes of natural water Relative abundance and treatment reduction of viruses during wastewater treatment processes -Identification of potential viral indicators. Science of The Total Environment 488-489 Waterborne Enteroviruses as a Hazard for Human Health Assessment of human adenovirus removal in a full-scale membrane bioreactor treating municipal wastewater Emerging and potentially emerging viruses in water environments First detection of SARS-CoV-2 in untreated wastewaters in Italy Electron Microscopy of Viruses Pulsed Field Gel Electrophoresis ☆ Evaluation of electropositive filtration for recovering norovirus in water Capsid integrity quantitative PCR to determine virus infectivity in environmental and food applications; a systematic review (preprint). Occupational and Environmental Health Polyethylene glycol precipitation for recovery of pathogenic viruses, including hepatitis A virus and human rotavirus, from oyster, water, and sediment samples UV inactivation and resistance of rotavirus evaluated by integrated cell culture and real-time RT-PCR assay Introduction to the Polymerase Chain Reaction SARS-CoV-2 in wastewater: potential health risk, but also data source Pulsed Field Gel Electrophoresis: Past, present, and future 2019-nCoV transmission through the ocular surface must not be ignored. The Lancet 395, e39 Viral Capsids and Envelopes: Structure and Function Rapid quantification of bacteria and viruses in influent, settled water, activated sludge and effluent from a wastewater treatment plant using flow cytometry Real-time PCR in virology Can a Paper-Based Device Trace COVID-19 Sources with Wastewater-Based Epidemiology? Characterisation of the sewage virome: comparison of NGS tools and occurrence of significant pathogens Duplex RT-qPCR for the detection of hepatitis E virus in water, using a process control High occurrence of hepatitis E virus in samples from wastewater treatment plants in Switzerland and comparison with other enteric viruses Assessment of airborne virus contamination in wastewater treatment plants Presence of human noro-and adenoviruses in river and treated wastewater, a longitudinal study and method comparison The Impact of Capsid Proteins on Virus Removal and Inactivation during Water Treatment Processes. Microbiol�Insights 8s2, MBI.S31441 Quantification of Human Polyomaviruses JC Virus and BK Virus by TaqMan Quantitative PCR and Comparison to Other Water Quality Indicators in Water and Fecal Samples Presence of SARS-Coronavirus-2 RNA in sewage and correlation with reported COVID-19 prevalence in the early stage of the epidemic in the Netherlands Use of Membrane Filters to Facilitate the Recovery of Virus from Aqueous Suspensions1 Development of an Effective Method for Recovery of Viral Genomic RNA from Environmental Silty Sediments for Quantitative Molecular Detection Quantification of Enterovirus RNA in Sludge Samples Using Single Tube Real-Time RT-PCR Pathogenic Enteric Viruses and Microbial Indicators during Secondary Treatment of Municipal Wastewater Optimization of a Reusable Hollow-Fiber Ultrafilter for Simultaneous Concentration of Enteric Bacteria, Protozoa, and Viruses from Water Virus Taxonomy and Nomenclature, in: Laboratory Diagnosis of Infectious Diseases Principles and Practice Pulsed field gel electrophoresis: Theory, instruments and application Temporal detection and phylogenetic assessment of SARS-CoV-2 in municipal wastewater (preprint) Nucleic Acid-Based Methods of Analysis High Variety of Known and New RNA and DNA Viruses of Diverse Origins in Untreated Sewage Viral Nucleic Acids Comparison of 2 ultrafiltration systems for the concentration of seeded viruses from environmental waters 51 Determination of Virus Abundance by Epifluorescence Microscopy Human enteric bacteria and viruses in five wastewater treatment plants in the Eastern Cape, South Africa Abundance, Diversity, and Dynamics of Viruses on Microorganisms in Activated Sludge Processes Detection and Molecular Characterization of Hepatitis A Virus from Tunisian Wastewater Treatment Plants with Different Secondary Treatments Assessment of airborne enteric viruses emitted from wastewater treatment plant: Atmospheric dispersion model, quantitative microbial risk assessment, disease burden SARS-CoV-2 RNA concentrations in primary municipal sewage sludge as a leading indicator of COVID-19 outbreak dynamics (preprint) Environmental Sample Collection and Processing Variability in the recovery of a virus concentration procedure in water: Implications for QMRA Rotavirus diarrhea in children and adults in a southern city of Brazil Evaluation of 1MDS electropositive microfilters for simultaneous recovery of multiple microbe classes from tap water Fluorescence instrument for in situ monitoring of viral abundance in water, wastewater and recycled water Performance of wastewater reclamation systems in enteric virus removal Detection of enteric viruses in activated sludge by feasible concentration methods Quantification and molecular characterization of enteric viruses detected in effluents from two hospital wastewater treatment plants A one-step centrifugal ultrafiltration method to concentrate enteric viruses from wastewater UV inactivation of human infectious viruses at two full-scale wastewater treatment plants in Canada SARS-CoV-2 RNA titers in wastewater anticipated COVID-19 occurrence in a low prevalence area (preprint). Occupational and Environmental Health Integrated Cell Culture/PCR for Detection of Enteric Viruses in Environmental Samples Presence and vitality of SARS-CoV-2 virus in wastewaters and rivers (preprint) PCR Inhibitor Levels in Concentrates of Biosolid Samples Predicted by a New Method Based on Excitation-Emission Matrix Spectroscopy Application of PCR-Based Methods To Assess the Infectivity of Enteric Viruses in Environmental Samples Virus detection by transmission electron microscopy: Still useful for diagnosis and a plus for biosafety Metagenomic analysis of viruses, bacteria and protozoa in irrigation water Detection of enteric viruses in municipal sewage sludge by a combination of the enzymatic virus elution method and RT-PCR Chemical disinfection of non-porous inanimate surfaces experimentally contaminated with four human pathogenic viruses Reverse Transcription, in: Brenner's Encyclopedia of Genetics Detection of enteric viruses in sewage sludge and treated wastewater effluent Methods to remove inhibitors in sewage and other fecal wastes for enterovirus detection by the polymerase chain reaction Sensitive detection of human adenovirus from small volume of primary wastewater samples by quantitative PCR Comparative enteric viruses and coliphage removal during wastewater treatment processes in a sub-tropical environment Effectiveness of Poliovirus Concentration and Recovery from Treated Wastewater by Two Electropositive Filter Methods Metavirome Sequencing to Evaluate Norovirus Diversity in Sewage and Related Bioaccumulated Oysters Cythopatic Effects_Protocol.pdf Eukaryotic Viruses in Wastewater Samples from the United States A case study of enteric virus removal and insights into the associated risk of water reuse for two wastewater treatment pond systems in Bolivia Metagenomic analysis of DNA viruses in a wastewater treatment plant in tropical climate: Viral metagenomics in a WWTP SARS-CoV-2 RNA detection of hospital isolation wards hygiene monitoring during the Coronavirus Disease 2019 outbreak in a Chinese hospital Excretion and detection of SARS coronavirus and its nucleic acid from digestive system Concentration and detection of SARS coronavirus in sewage from Xiao Tang Shan Hospital and the 309th Hospital Study on the resistance of severe acute respiratory syndromeassociated coronavirus Detection and monitoring of virus infectionsby realtime PCR Demonstration of solids-associated virus in wastewater and sludge Accurate Estimation of Viral Abundance by Epifluorescence Microscopy Quantification of Enteric Viruses, Pathogen Indicators, and Salmonella Bacteria in Class B Anaerobically Digested Biosolids by Culture and Molecular Methods SARS-CoV-2 titers in wastewater are higher than expected from clinically confirmed cases (preprint) Determination of virus abundance, diversity and distribution in a municipal wastewater treatment plant Prolonged presence of SARS-CoV-2 viral RNA in faecal samples Evaluation of lockdown impact on SARS-CoV-2 dynamics through viral genome quantification in Paris wastewaters (preprint) Fate of Viruses in Water Systems Evidence for Gastrointestinal Infection of SARS-CoV-2 Survivability, Partitioning, and Recovery of Enveloped Viruses in Untreated Municipal Wastewater Survivability, Partitioning, and Recovery of Enveloped Viruses in Untreated Municipal Wastewater Enteric involvement of coronaviruses: is faecal-oral transmission of SARS-CoV-2 possible? Potential spreading risks and disinfection challenges of medical wastewater by the presence of Severe Acute Payne Viruses in Wastewater: Occurrence, Abundance and Detection Methods Pietro Campiglia f , Vincenzo Belgiorno b,c , Gregory Korshin g , Vincenzo Naddeo b,c* a Environmental Engineering Program The authors would like to express their sincere gratitude to the support from i) Sanitary Environmental Engineering Division (SEED) and grants (FARB projects) from University of Salerno coordinated by prof. V. Naddeo; ii) Inter-University Consortium of Relevant Hazardous (Consorzio inter-Universitario per la previsione e la prevenzione dei Grandi Rischi, C.U.G.RI.);