key: cord-0960412-rxajk1c9 authors: Ding, Xin; Chen, Huan; Zhao, Hua; Zhang, Hongmin; He, Huaiwu; Cheng, Wei; Wang, Chunyao; Jiang, Wei; Ma, Jie; Qin, Yan; Liu, Zhengyin; Wang, Jinglan; Yan, Xiaowei; Li, Taisheng; Zhou, Xiang; Long, Yun; Zhang, Shuyang title: ECCO(2)R in 12 COVID-19 ARDS Patients With Extremely Low Compliance and Refractory Hypercapnia date: 2021-07-08 journal: Front Med (Lausanne) DOI: 10.3389/fmed.2021.654658 sha: 1d0f11fe139d4aba41b2017aa6a3f362a15f2343 doc_id: 960412 cord_uid: rxajk1c9 Purpose: A phenotype of COVID-19 ARDS patients with extremely low compliance and refractory hypercapnia was found in our ICU. In the context of limited number of ECMO machines, feasibility of a low-flow extracorporeal carbon dioxide removal (ECCO(2)R) based on the renal replacement therapy (RRT) platform in these patients was assessed. Methods: Single-center, prospective study. Refractory hypercapnia patients with COVID-19-associated ARDS were included and divided into the adjusted group and unadjusted group according to the level of PaCO(2) after the application of the ECCO(2)R system. Ventilation parameters [tidal volume (VT), respiratory rate, and PEEP], platform pressure (Pplat) and driving pressure (DP), respiratory system compliance, arterial blood gases, and ECCO(2)R system characteristics were collected. Results: Twelve patients with refractory hypercapnia were enrolled, and the PaCO(2) was 64.5 [56-88.75] mmHg. In the adjusted group, VT was significantly reduced from 5.90 ± 0.16 to 5.08 ± 0.43 ml/kg PBW; DP and Pplat were also significantly reduced from 23.5 ± 2.72 mmHg and 29.88 ± 3.04 mmHg to 18.5 ± 2.62 mmHg and 24.75 ± 3.41 mmHg, respectively. In the unadjusted group, PaCO(2) decreased from 94 [86.25, 100.3] mmHg to 80 [67.50, 85.25] mmHg but with no significant difference, and the DP and Pplat were not decreased after weighing the pros and cons. Conclusions: A low-flow ECCO(2)R system based on the RRT platform enabled CO(2) removal and could also decrease the DP and Pplat significantly, which provided a new way to treat these COVID-19 ARDS patients with refractory hypercapnia and extremely low compliance. Clinical Trial Registration: https://www.clinicaltrials.gov/, identifier NCT04340414. Recently, COVID-19 disease caused by the novel coronavirus (SARS-CoV-2) has been a worldwide severe epidemic problem and resulted in thousands of deaths (1) . Respiratory manifestation was one of the main clinical characteristics of this disease; about 15-20% of suspected and confirmed patients developed severe hypoxemia and required mechanical ventilation (2) . Gattinoni et al. divided the COVID-19 pneumonia into two phenotypes: Type L and Type H (3), but in our clinical practice in Wuhan, we encountered a group of ARDS patients who presented a different phenotype from the two mentioned above, with refractory carbon dioxide (CO 2 ) retention, extremely low lung compliance, and low lung recruitability, which was also found in other centers (4, 5) . Hypercapnia not only impairs innate immunity via evolutionarily conserved mechanisms (6) , which reduce the ability to fight infection, but also has hemodynamic consequence, increasing pulmonary hypertension and worsening right ventricular function (7) . A recent study showed that severe hypercapnia (PaCO 2 ≥ 50 mmHg) appeared to be independently associated with higher ICU mortality in patients with ARDS (8) . In order to correct the severe hypercapnia, minute ventilation and drive pressure were often forced to increase to far beyond the level of lung protective ventilation. This means higher mechanical energy and a higher risk of ventilator-related lung injury (9, 10) . Therefore, extracorporeal carbon-dioxide removal (ECCO 2 R) device came into our consideration. In this sudden outbreak of COVID-19, like all countries in the world (11) , the number of ECMO machines has been in a state of serious shortage for quite a long time, and also the specific ECCO 2 R system. However, the RRT device is more feasible, and recent studies had improved that, ECCO 2 R based on a RRT platform enabled very low tidal volume ventilation with moderate increase in PaCO 2 in patients with ARDS patients (12, 13) . Therefore, this prospective study was designed to assess whether the application of the ECCO 2 R system on RRT platform could decrease the DP and Pplat, thereby facilitated the protective ventilation in these patients. This single-center, prospective study was conducted during March 7 to April 15 in a newly constructed 32-bed ICU in Wuhan. All the medical staff were from Peking Union Medical College Hospital (PUMCH); 70% of them had experiences in the ICU ward. All the patients admitted were transferred from other hospitals and were all identified with COVID-19. This study was approved by the ethics review board of PUMCH (ZS-2332), and informed consent was obtained from legally authorized surrogates. The clinical trial protocol was registered with www.clinicaltrials.gov/ (Clinicaltrials.gov identifier: NCT04340414). Refractory hypercapnia patients with COVID-19-associated ARDS were included, if the following inclusion criteria were met: (1) diagnosed with ARDS according to the Berlin definition and lung protective strategy was implemented after admission, which included low tidal volume (VT) ventilation (Vt 6 ml/kg of predicted body weight), low plateau pressure (Pplat < 30 cmH 2 O), higher PEEP strategy, and prone positioning 16-20 h per day; (2) evolved into refractory hypercapnia (PaCO 2 > 50 mmHg), despite efforts of correcting CO 2 retention by increasing the respiratory rate and driving pressure. The exclusion criteria were patients with ICU stay < 24 h, decompensated heart failure, pregnancy, age < 18 years, acute brain injury, contradictions of systemic anticoagulation, catheter access to femoral vein or jugular vein impossible, and decision to limit therapeutic interventions. The ECCO 2 R was provided by a low-flow gas-exchanger oxygenator (QUADROX-I pediatric HMO30000, MAQUET) integrated into the Primsaflex platform (Gambro-Baxter) with the slow continuous ultrafiltration (SCUF) mode, and the ultrafiltration was set at 0. The polymethyl pentene, hollow fiber, gas-exchanger membrane was connected to the extracorporeal circuit before the RRT filter (Figure 1) . Two 12-Fr twolumen hemodialysis catheters (arrow) were aseptically and percutaneously inserted under ultrasonography guidance into the right jugular vein and one of the femoral veins with a femoral-jugular pattern to prevent self-recirculation and improve the clearance efficiency. Systemic heparinization was used to maintain the activated partial thromboplastin time ratio (aPTTr) 1.5-2.0× that of the control. The continuous venous, arterial line and filter pressures were monitored in the Prismaflex device. After priming, the Prismaflex device was connected to the patient and the extracorporeal blood flow was progressively increased to 300-400 ml/min. In the beginning, a flow test was done to assess the efficiency of CO 2 clearance of the membranes. Pre-and postoxygenator blood PCO 2 were compared when the sweep flow was adjusted to 0, 5, 10, and 15 L/min, and back to 0 L/min. Then, the sweep-gas flow through the ECCO 2 R was switched on the level with the best clearance efficiency. The changes of CO 2 clearance with time were also collected. Half an hour later after, according to the arterial PaCO 2 , the patients were divided into two groups. If the PaCO 2 decreased to lower than 50 mmHg, VT was gradually reduced from 6 to 5, 4.5 every 30 min until the PaCO 2 returned to the original level and the pH > 7.2. If the PaCO 2 still remained above 50 mmHg, the VT would not be changed and the ECCO 2 R device was only used to reduce the hypercapnia. Refractory hypoxemia and/or hypercapnia could be managed at the attending physician's discretion, with recruitment maneuver, prone positioning, and so on. The flowchart is shown in Figure 2 . Ventilator settings (VT, PEEP, RR, Pplat, minutes ventilation, and FiO 2 ), hemodynamic parameters (MAP, HR, and vasopressor dose), arterial blood-gas values (pH, PaO 2 , PaCO 2 , HCO 3− , and lactate), heparin dose, and aPTTr were collected at baseline. After the run-in time, 30 min, 6 h, and 24 h after the connection, these values were also collected. Other variables such as complete blood count, liver function, and renal function were obtained daily. Respiratory-system compliance, driving pressure, and the mechanical power were calculated according to the standard formulas. Results are expressed as median (IQR) when abnormal distribution, and as mean ± SD when normal distribution, and both p < 0.05 defined statistical significance. Statistical analysis was performed using non-parameter analysis in chi-square test for comparison between different time intervals when distributed abnormally and using one-way analysis of variance (ANOVA) for repeated measures, followed by a post-hoc test, when distributed normally. Analyses were computed with IBM SPSS, version 23.0.1 (SPSS Inc., Chicago, IL, USA) software. Thirty-two patients with ARDS were involved, and lung protective strategy worked in 17 patients with PaCO 2 < 50 mmHg, and three patients died within 24 h after admission. After the adjustment of ventilator parameters, PaCO 2 was still above 50 mmHg (64.5 [56-88.75] mmHg) in 12 patients and the ECCO 2 R devices were applied. At baseline, all these patients received protective ventilation with VT set at 5.94 ± 0.18 ml/kg PBW and PEEP at 6 [5.25, 8 .0] cmH 2 O, the respiratory rate was 32.58 ± 3.55 bpm, and the platform pressure and the driving pressure were 34.08 ± 6.91 mmHg and 27.17 ± 5.98 mmHg ( Table 1) . The mean blood flow was 342.5 ± 49.20 ml/min, and in the flow test, when the sweep-gas flow was set at 10 L/min, the CO 2 clearance reached the best efficiency, 45.91 ± 7.70 ml/min. In all these patients, the flow was set at 10 L/min during the process. After the application of the ECCO 2 R device, the PaCO 2 in all the patients decreased, and during the 24 h, the CO 2 clearance nearly did not change little with time (Figure 3) . There was no significant correlation between the CO 2 clearance and the start PaCO 2 , the DP, and lung compliance. In eight of these patients, the PaCO 2 could decrease below 50 mmHg, and the VT was reduced every 30 min until the PaCO 2 returned; in the other four patients, the PaCO 2 was still above 50 mmHg, and VT was not reduced. According to whether the VT was adjusted, we divided the 12 patients into two groups, adjusted group (n = 8) and unadjusted group (n = 4). In the adjusted group, 6 h after the flow test, VT was decreased from 5.9 ± 0.16 to 5.08 ± 0.43 ml/kg PBW (p < 0.01), and DP and Pplat were also decreased significantly from 23.5 ± 2.72 mmHg and 29.88 ± 3.04 mmHg to 18.5 ± 2.62 mmHg (p < 0.01) and 24.75 ± 3.41 mmHg (p < 0.01). Furthermore, the mechanical power decreased from 21.25 ± 2.45 to 18.37 ± 2.76 mmHg, with no statistically significant difference (p = 0.16). Twenty-four hours later, the DP and Pplat slightly increased, but were still significantly reduced compared with the baseline (Figure 4) . In The result of this single-center, prospective study showed that, in a group of COVID-19 ARDS patients with refractory hypercapnia and extremely low compliance, a low-flow ECCO 2 R system based on the RRT platform can easily and safely reduce the PaCO 2 level and significantly decrease the Pplat and driving pressure in moderate hypercapnia patients. Hypercapnia was common with lung protective volume ventilation in COVID-19-related ARDS patients and could be corrected with an intermediate tidal volume (7-8 ml/kg PBW) in some patients (4, 5) . The conditions were more severe in our ICU, as 37.5% (12/32) of the ARDS patients had refractory hypercapnia despite ventilated with higher DP and higher respiratory rate than usual, and the lung compliance of our patients were relatively lower than reported in other centers. As in these patients, the hypercapnia occurred in the late stage of this disease in critical patients, which was 43.5 [32.5-47] days after the symptom onset, a reminder that the disease was still in progression at that time. Second, the bilateral diffuse ground-glass opacities and reticulation, compensatory emphysema, architectural distortion, and traction bronchiectasis were typical radiographic features on the CT in severe patients (14, 15) , which indicated increased pulmonary dead space in these patients. Last, pathological findings such as exudation and mucous plug with fibrinous exudate in the alveoli could cause ventilatory disfunction. Although, in the early 1990s, the concept of permissive hypercapnia was proposed for patients with acute lung injury, more studies have reported that hypercapnia has a lot of harmful effects, which include inhibition of cell membrane repair, impairment of alveolar fluid clearance, suppression of innate immunity and host defense (16) (17) (18) , and significant hemodynamic consequences such as pulmonary hypertension and right ventricular dysfunction (19) . Recent data suggest an association between values of PaCO 2 > 50 mmHg and increased mortality (8); therefore, CO 2 clearance is a necessary treatment in these patients. The present study showed that CO 2 clearance could be reached at 45.91 ± 7.70 ml/min, with the low-flow ECCO 2 R device with RRT platform. None of the severe adverse events occurred, although various AEs (e.g., cannulation-related accidents, hemorrhage, pump malfunction, and membrane clotting) were reported (12, 20, 21) . Apart from hypercapnia, the elevated driving pressure and the mechanical power were problems we were more worried about. Because of the low lung compliance of these patients, the driving pressure and the Pplat of these patients were still very high despite protective ventilation with 6 ml/kg. Actually, recent data have demonstrated that there is no safe upper limit for Pplat or DP, and the mortality rate with DP ≤ 14 cmH 2 O is still as far as 20% (9, 22) . As the ventilation variable with the best stratified risk, patient outcomes may be improved with the decreasing of DP owing to changes in ventilator settings such as VT (9) , and the mechanical power also showed a strong correlation with mortality risk (10) . Therefore, in our study, when the PaCO 2 was reduced with the low-flow ECCO 2 R device, we preferred to decrease the DP and mechanical power first in the moderate hypercapnia group by reducing the VT gradually. In these patients, the DP was significantly reduced, and mechanical power was also reduced, although without statistical significance. Our results demonstrated that, in these special group of COVID-19 ARDS patients, this low-flow ECCO 2 R system could be easily, safely, and efficiently applied, because the RRT platform is widely available, and it did not require specific venous access. As none of the medications had been proven to be effective in the critical patients with COVID-19, and the ECMO were not adequate in many ICUs (11) , this low-flow ECCO 2 R system could provide a new way of correcting the respiratory acidosis and decreasing the DP, apart from the traditional methods such as prone positioning, recruitment maneuver, nitric oxide, and so on. It may help in the effort to reduce mortality in this global campaign against COVID-19. Several limitations of our work should be addressed. First, only 12 critically ill patients were included. Although this system has been proven to be effective and safe in mild-to-moderate ARDS patients (12) , because of the shortage of resources, only patients with the most needs were included, which were the refractory hypercapnia patients. Due to the exploratory nature of the study, which was not driven by formal hypotheses, the sample size calculation was waived. Instead, we hope that the findings present here will encourage a larger cohort study in these special patients. Second, the CO 2 removal rate of this system was lower than those reported in other studies (23) , and the lower blood flows and catheters with faster flow rate could be considered to improve the CO 2 removal rate. Last, this study was mainly conducted to prove the feasibility of such an ECCO 2 R system applied to refractory hypercapnia patients with COVID-19-associated ARDS, and the system was limited FIGURE 4 | Evaluation of VT, Pplat, DP, and mechanical power when tidal volume was reduced on ECCO 2 R in the adjusted group. Vt, tidal volume; Pplat, end-inspiratory plateau pressure; DP, driving pressure; MP, mechanical power. *p < 0.05 vs. Baseline. to a period of 24 h, as there was a theoretical risk of rupture of the circuit, and the influence of the outcome of these patients was limited. We reported a group of COVID-19 ARDS patients with refractory hypercapnia and extremely low compliance and have demonstrated that a low-flow ECCO 2 R system based on the RRT platform enabled CO 2 removal and could also decrease the DP and Pplat significantly. This less-invasive ECCO 2 R technique was easily and safely implemented and provided a new way for intensivists in the global campaign against COVID-19. The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation. Ethical review and approval was not required for the study on human participants in accordance with the local legislation and institutional requirements. The patients/participants provided their written informed consent to participate in this study. XZ and YL: study conceptualization and writing-review and editing. XD, HC, HuZ, HoZ, and HH: study design. XD, HC, HuZ, HoZ, HH, WC, CW, WJ, YQ, ZL, JW, XY, TL, and SZ: methodology. XD, HC, HuZ, and HoZ: formal analysis and investigation. XD, HC, and HuZ: writing-original draft preparation. All authors commented on a previous version of the manuscript and all authors read and approved the final manuscript. Clinical predictors of mortality due to COVID-19 based on an analysis of data of 150 patients from Wuhan, China China critical care clinical trials: intensive care during the coronavirus epidemic COVID-19 pneumonia: different respiratory treatments for different phenotypes? Lung recruitability in COVID-19-associated acute respiratory distress syndrome: a singlecenter observational study Ventilatory ratio in hypercapnic mechanically ventilated patients with COVID-19-associated acute respiratory distress syndrome Elevated CO2 levels affect development, motility, and fertility and extend life span in Caenorhabditis elegans Impact of acute hypercapnia and augmented positive end-expiratory pressure on right ventricle function in severe acute respiratory distress syndrome Severe hypercapnia and outcome of mechanically ventilated patients with moderate or severe acute respiratory distress syndrome Driving pressure and survival in the acute respiratory distress syndrome What links ventilator driving pressure with survival in the acute respiratory distress syndrome? A computational study Extracorporeal membrane oxygenation for severe acute respiratory distress syndrome associated with COVID-19: a retrospective cohort study Feasibility and safety of low-flow extracorporeal CO2 removal managed with a renal replacement platform to enhance lung-protective ventilation of patients with mild-to-moderate ARDS Low flow extracorporeal CO2 removal in ARDS patients: a prospective short-term crossover pilot study Imaging changes of severe COVID-19 pneumonia in advanced stage Relation between chest CT findings and clinical conditions of coronavirus disease (COVID-19) pneumonia: a multicenter study Bench-to-bedside review: carbon dioxide Hypercapnic acidosis impairs plasma membrane wound resealing in ventilator-injured lungs Hypercapnia: a nonpermissive environment for the lung Experts' opinion on management of hemodynamics in ARDS patients: focus on the effects of mechanical ventilation Lower tidal volume strategy (approximately 3 ml/kg) combined with extracorporeal CO2 removal versus 'conventional' protective ventilation (6 ml/kg) in severe ARDS: the prospective randomized Xtravent-study The feasibility and safety of extracorporeal carbon dioxide removal to avoid intubation in patients with COPD unresponsive to noninvasive ventilation for acute hypercapnic respiratory failure (ECLAIR study): multicentre case-control study Fifty years of research in ARDS. Vt selection in acute respiratory distress syndrome Safety and efficacy of combined extracorporeal CO2 removal and renal replacement therapy in patients with acute respiratory distress syndrome and acute kidney injury: the pulmonary and renal support in acute respiratory distress syndrome study The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.Copyright © 2021 Ding, Chen, Zhao, Zhang, He, Cheng, Wang, Jiang, Ma, Qin, Liu, Wang, Yan, Li, Zhou, Long and Zhang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.