key: cord-0953578-16qb5i28 authors: Shahabi, Javad; Askari, Mozhde; Azhari, Amirhossein; Kermani‐Alghoraishi, Mohammad title: The survey of electrophysiology lab activity during the COVID‐19 pandemic date: 2021-06-24 journal: J Arrhythm DOI: 10.1002/joa3.12584 sha: dde6d8281d545411f7c62b9b84fd19909f8695f1 doc_id: 953578 cord_uid: 16qb5i28 BACKGROUND: With the onset and spread of the COVID‐19 pandemic, the hospitalization and treatment of noncovid patients were dramatically affected. The aim of this study is to evaluate the electrophysiology (EP) lab activity in a referral center in Iran during the COVID‐19 era. METHODS: A cross‐sectional descriptive survey was conducted on EP lab activity in Shahid Chamran Heart Center, Isfahan, Iran. Two periods of COVID‐19 occurrence peaks in Iran were compared with same date in 2019. Information was collected on number of diagnostic and therapeutic electrophysiology studies (EPSs) and implantation of intracardiac devices such as permanent pacemaker (PPM), implantable cardioverter defibrillator (ICD), and cardiac resynchronization therapy (CRT). RESULTS: In the first peak of COVID‐19 pandemic, both of EPSs and intracardiac device implantations decreased by 80% compared to the same period in 2019. The most common type of device implanted during this period was PPM (70%); however, at the time of control, the ICD (73%) was the most common. Paroxysmal supraventricular tachyarrhythmia (PSVT) was the best indication for diagnostic and therapeutic EPSs in covid and control periods. In the second peak of prevalence of COVID‐19 virus infection in Iran, 6% and 36% decreases in device implantations and EPSs were seen, respectively. During this period, the number of procedures increased, although it was still lower than in 2019. CONCLUSION: A significant reduction in the EP lab activity has been observed during both the COVID‐19 pandemic peaks. Background: With the onset and spread of the COVID-19 pandemic, the hospitalization and treatment of noncovid patients were dramatically affected. The aim of this study is to evaluate the electrophysiology (EP) lab activity in a referral center in Iran during the COVID-19 era. Shahid Chamran Heart Center, Isfahan, Iran. Two periods of COVID-19 occurrence peaks in Iran were compared with same date in 2019. Information was collected on number of diagnostic and therapeutic electrophysiology studies (EPSs) and implantation of intracardiac devices such as permanent pacemaker (PPM), implantable cardioverter defibrillator (ICD), and cardiac resynchronization therapy (CRT). In the first peak of COVID-19 pandemic, both of EPSs and intracardiac device implantations decreased by 80% compared to the same period in 2019. The most common type of device implanted during this period was PPM (70%); however, at the time of control, the ICD (73%) was the most common. Paroxysmal supraventricular tachyarrhythmia (PSVT) was the best indication for diagnostic and therapeutic EPSs in covid and control periods. In the second peak of prevalence of COVID-19 virus infection in Iran, 6% and 36% decreases in device implantations and EPSs were seen, respectively. During this period, the number of procedures increased, although it was still lower than in 2019. A significant reduction in the EP lab activity has been observed during both the COVID-19 pandemic peaks. COVID-19, EP lab, implantable cardioverter defibrillator, permanent pacemaker of these protocols was to reduce the exposure of medical staff to SARS-Cov-2 virus as well as reduction in nonemergency diagnostic and therapeutic procedures to take maximum advantage of structural and functional capacity of hospitals. [2] [3] [4] However, with the prolongation of the pandemic and increasing recognition of the nonpulmonary complications of COVID-19, such as cardiovascular disease, the need to return all health services of hospitals was felt. Among these, cardiac electrophysiological studies (EPSs) and implantation of intracardiac devices were significantly decreased during the COVID-19 era; however, increased incidence of cardiac arrhythmias in COVID-19-infected patients, greater incidence of ischemic (because of delay for appropriate treatment) and nonischemic cardiomyopathies, and economic and social stress arising from quarantine rules are reasons why these procedures are necessary. [5] [6] [7] [8] Statistics and information about the activity of electrophysiology laboratory (EP lab) did not publish much during the COVID-19 era, so given the preventive importance of this issue, we seek to provide data about our EP lab activities regarding diagnostic and therapeutic procedures in COVID-19 pandemic period and compare it with non-COVID-19 period. and 20 May 2020, and second peak between 21 June 2020 and 21 September 2020. The same date in 1 year ago (2019) was defined as control period. All data were collected during the 10 days from 25 September to 5 October from hospital registry, electrophysiology department. Because of all data were anonymized, ethical approval was not required. Our main objectives were quantity of diagnostic and therapeutic EPSs and intracardiac device implantations procedures in the first and second COVID-19 peaks in Iran in comparison to pre-COVID-19 condition. In the first peak, we experienced restricted quarantine rules for general population and health centers, whereas in the second courier, quarantine rules became more limited. Medical indications of these procedures are mentioned as secondary variables. Quantitative data were analyzed as mean and standard deviation, whereas qualitative data were presented as number and percentages. To compare quantitative data between the two mentioned times, independent t test was used and, for qualitative data Chi-square test and, if necessary, Fisher's exact test was used. P-value below 0.05 was considered as a significant level. Statistical Package for the Social Sciences (SPSS) version 24.0 was used to analyze the data. In the first peak of COVID-19 pandemic, 10 patients were under intracardiac device implantation and 11 patients were under EPS, whereas in the same time of this period 48 patients were under intracardiac device implantation and 55 patients were under EPS (80% decrease). There was no significant difference between first COVID-19 pandemic and control period based on age and gender in the patients under device implantation (P > .05). In the first peak of coronavirus outbreak, PPM implantation as a result of atrioventricular node or sinoatrial node diseases (40%) was the most common reason for implantation of intracardiac device (70%), while in the same period in 2019, ICD implantation because of cardiomyopathies (35.4%) was the most common (73%). In general, there was a significant difference in the number intracardiac device implantation between the COVID-19 and noncovid era (P = .03) ( Table 1) . For the patients under diagnostic and therapeutic EPSs, the most common cases in first COVID-19 pandemic peak and control period were paroxysmal supraventricular tachyarrhythmia (PSVT) including atrioventricular nodal reentry tachycardia and atrioventricular reentry tachycardia (63.6% and 38.1%, respectively). There was no significant difference between first COVID-19 pandemic peak and control period based on gender and EPS indications (P > .05). The mean age in the first COVID-19 pandemic was significantly higher than control period in patients under EPSs (P = .02) ( Table 2 ). In the second COVID-19 pandemic peak, 123 patients were under intracardiac device implantation and 77 patients were under EPS and, at the same time of this period in the past year (control period), 131 patients were under device implantation and 121 patients were under EPS. The number of cases in the second COVID-19 pandemic period was decreased 6% for intracardiac device implantation and 36% for EPS compared to control period. There was no significant difference between second COVID-19 pandemic peak and control period based on age and gender in patients (P >.05). The most common indication for device implantation in second peak of COVID-19 pandemic and same control period was cardiomyopathy (41.9% vs 29.5%). During this period, there was also a significant difference between the coronavirus period and control time in terms of the total number of intracardiac devices implantation (P =.008) ( Table 3 ). The most common indication for EPSs in both second COVID-19 pandemic peak and control period was PSVT as well (45.4% and 53.7%, respectively) ( Table 4) . No COVID-19 patients underwent diagnostic study in either peaks. Among the statistics provided, 1 patient (PPM) in the first peak and 11 patients (PPM: 10 cases, ICD: 1 case) during the second peak needed emergency intracardiac device implantation. Based on our results, the number of cases for intracardiac device implantation and EPSs was decreased in the first COVID-19 pandemic peak compared to the same time of the past year. This decrease was also evident in the second peak of pandemic; however, compared to the first peak, it was less different from the control period. The reduction in device implantation and EPSs in the first COVID-19 pandemic was 80% for both, but in the second COVID-19 pandemic peak were 6% for device implantation and 36% for EPSs. The point is that the decrease in EP lab activity in both COVID-19 pandemic peaks is caused by this unprecedented epidemic in Iran, but the further decrease in device implantation and EPS cases in the first pandemic peak was as a result of the Ministry of Health's restrictions on services for elective patients and the lack of insurance coverage for these services. On the other hand, the social restrictions on dealing with the COVID-19 pandemic were much greater in the first peak, so that most invasive and noninvasive procedures were canceled. In the second pandemic, most of the social and health restrictions were reduced. There is also the hypothesis that patients were afraid to go to medical centers during the pandemic, especially during the first peak. As the pandemic trend continued, although the EP lab activity increased, it was still lower than in the previous year, which could be because of the reluctance of physicians and medical staff to perform elective procedures, con- Ultimately, this survey showed that as more time elapses since the pandemic outbreak and as we acquire a sound understanding of principles of diseases prevention and treatment, the performance of medical centers gradually reverts to its standard form. However, the prevalence and severity of COVID-19 in each region will determine the therapeutic approaches of the centers in each period. The single-center assessment is the limitation of this study, although it is a large and referral hospital in central of Iran and can reflect the activities of other centers. Lack of information about the consequence of the patients for whom their diagnostic and therapeutic approaches, especially intracardiac devices implantation, were postponed or cancelled is the other limitation of this survey. to hospitals as patients/medical staff fearing to infect of COVID-19 and/or low willingness of the health-care system to provide these services. All authors have no financial interests to disclose and no conflicts of interest to declare. None. Mohammad Kermani-Alghoraishi https://orcid. org/0000-0002-3701-3572 A novel coronavirus outbreak of global health concern. The Lancet The European Society for Cardiology. ESC Guidance for the Diagnosis and Management of CV Disease during the COVID-19 Pandemic Managing ACS during COVID-19 infection: Do not follow the traditional route EAPCI position statement on invasive management of acute coronary syndromes during the COVID-19 pandemic Impact of COVID-19 on pacemaker implant Electrophysiology in the time of coronavirus: coping with the great wave COVID-19 and cardiac arrhythmias The survey of electrophysiology lab activity during the COVID-19 pandemic