key: cord-0951827-ewnzqu6i authors: Hitzenbichler, Florian; Bauernfeind, Stilla; Salzberger, Bernd; Schmidt, Barbara; Wenzel, Jürgen J. title: Comparison of Throat Washings, Nasopharyngeal Swabs and Oropharyngeal Swabs for Detection of SARS-CoV-2 date: 2021-04-10 journal: Viruses DOI: 10.3390/v13040653 sha: 1be17a888fab0950f2484be57efde5ba0e9ef1ac doc_id: 951827 cord_uid: ewnzqu6i Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) RNA is detected by reverse-transcription quantitative real-time PCR (RT-qPCR) from respiratory specimens. This study compares throat washings (TW), nasopharyngeal swabs (NS) and oropharyngeal swabs (OS). A total of 102 samples from 34 adult patients with confirmed SARS-CoV-2 infection were analysed by RT-qPCR with absolute quantification. The median concentrations and diagnostic sensitivities were [Formula: see text] copies/mL, 85% (NS), [Formula: see text] , 79% (OS) and [Formula: see text] , 85% (TW). Concentration differences were significant between NS and TW (P = 0.019). Saliva (SA) was available from 21 patients (median [Formula: see text]). OS and TW can be considered for SARS-CoV-2 diagnostics, although with slightly lower concentrations. Following the first appearance of a novel coronavirus (subsequently named SARS-CoV-2) at the end of December 2019 in Wuhan, China, a rapid worldwide spread occurred. The clinical presentation of infected individuals varies considerably, ranging from asymptomatic carriers to fatal multi-organ failure. Fast and reliable laboratory analysis from respiratory specimens is crucial for the placement and management of patients. The Robert Koch Institute in Germany recommends nasopharyngeal swabs for diagnosis of SARS-CoV-2 infection. The Centers for Disease Control and Prevention (CDC, Atlanta, USA) recommend nasopharyngeal or oropharyngeal swabs. Throat washing (gargling) is discussed as an alternative. Previous studies have reported various results on the diagnostic sensitivity of saliva or sputum [1] [2] [3] [4] . Each sampling method offers advantages and disadvantages in clinical routine. For example, nasopharyngeal swabs are more difficult to obtain and currently affected by global supply shortages. On the other hand, throat washings are easy to perform, but could increase the risk of aerosolization or negatively influence the detection rate. Reliable data on the diagnostic performance of throat washing compared to nasopharyngeal or oropharyngeal swabs are scarce. We aimed to compare the diagnostic sensitivity and concentration of SARS-CoV-2-specific RNA as derived by three sampling methods: throat washings (TW), nasopharyngeal swabs (NS) and oropharyngeal swabs (OS). Moreover, saliva samples were analyzed from a subset of the study participants. Between 27 April and 8 December 2020, thirty-four patients with coronavirus disease 2019 (COVID-19), who had been admitted to our non-intensive care medical ward, were included in this study. Inclusion criteria were: laboratory-confirmed SARS-CoV-2 infection (defined by a positive RT-qPCR result before inclusion) and age ≥ 18 years. All samples were collected by a single infectious diseases specialist in a defined sequence: (1) saliva (subset of 21 patients between May and December 2020), (2) oropharyngeal swab, (3) nasopharyngeal swab, and (4) throat washing. To obtain TW, patients were instructed to take 10 mL of medical grade saline or water in their mouth, gargle for 5-10 s (oscillating over the posterior pharyngeal wall) and transfer the liquid into a sterile test tube. NS and OS were obtained according to standard procedures. No combined swabs were collected. Only one nostril was probed for collecting NS. All specimens were analyzed within 24 h after collection. Swab specimens were resuspended in 1 mL of medical grade saline before extraction. Nucleic acid was isolated from 200 µL of sample on an EZ1 Advanced XL workstation using the EZ1 Virus Mini Kit v2.0 (Qiagen, Hilden, Germany) with 100 µL elution buffer. A defined amount of MS2 bacteriophages was added during extraction and served as an internal control for isolation, reverse transcription and amplification. The concentration of SARS-CoV-2-specific RNA was determined by RT-qPCR. Briefly, 5 µL eluate was used for one-step reverse transcription and amplification in a total reaction volume of 30 µL using the TaqPath TM 1-Step RT-qPCR Master Mix, CG (Thermo Fisher Scientific, Waltham, MA, USA). The PCR primers and fluorescent hydrolysis probe targeted the E-region of the viral genome [5] . Thermal cycling and real-time detection were performed on a StepOnePlus Real-Time PCR System (Thermo Fisher). The protocol was extended to allow absolute quantification of SARS-CoV-2 RNA as expressed in genome copies/mL (cp/mL). Therefore, standard curves were obtained by reverse transcription and amplification of a series of defined amounts of pre-characterized, in-vitro-transcribed and assay-specific RNA standards, generated as previously described for a different detection assay [6] . The specific target concentrations in the specimens were obtained by comparing the respective quantification cycles (Ct-values) to the standard curves. The analytical sensitivity (LoD 95 ) of the assay was ≤300 cp/mL of specimen (corresponding to ≤3 copies per reaction). SARS-CoV-2 RNA levels in sample groups were compared. Undetectable viral loads were set at 100 RNA cp/mL and a decadic logarithmic (log 10 ) transformation of measurements was performed prior to the statistical analysis (example: log 10 (1.0 × 10 5 ) = 5.0). The Shapiro-Wilk test was used to test for normal distribution. Levene's test was used to assess if samples were from populations with equal variances. The log 10 -transformed concentrations of groups were first analyzed by a linear mixed-effects model (LME). The null hypothesis (H 0 ) assumed no difference in mean concentrations between groups. If the LME analysis yielded a non-significant result, H 0 could not be falsified and no further analysis followed. When LME yielded a significant result, at least one of the means of the groups was assumed to be different from the others (H 0 falsified). In this case, post-hoc comparisons based on the LME followed between each group. All statistical analyses were performed using R, version 4.0.4 (The R Foundation for Statistical Computing, Vienna, Austria). The lmer() function implemented in the R-package lme4 was used for calculating the linear mixed-effects model. The emmeans() function from the R-package lmerTest was used for the post-hoc comparisons. P values of < 0.05 were considered to be statistically significant. Thirty-four individuals aged 22-83 years (mean 57.5 years) participated in the study. Eleven (32%) were female. Most patients were admitted with symptoms consistent with COVID-19. Three patients had no COVID-19 symptoms, were admitted for other medical issues and had a positive SARS-CoV-2 screening result. Only one patient (3%) was transferred to an intensive care unit and all patients survived. Detailed clinical and demographic characteristics are shown in Table 1 . Diagnostic samples were collected 6.1 ± 3.7 days (±SD) after symptom onset (range 0-15 days). A total of 102 TW, NS and OS specimens were analyzed. Saliva (SA) was tested in a subset of 21 patients between May and December 2020. The diagnostic sensitivity was assessed with regard to a positive RT-qPCR reference result before inclusion in the study. The median time between this pre-test and inclusion was 1.5 days (IQR 1-3, range 0-10). Overall, the diagnostic sensitivity was 85% for NS (29/34 positive), 79% for OS (27/34 positive) and 85% for TW (29/34 positive). SARS-CoV-2 RNA ranged from 0 (not detected) to 1.7 × 10 8 cp/mL (Table 2, Figure 1 ). Figure 1, panel A) . The log 10 -transformed SARS-CoV-2 RNA levels were compared between the three sample groups NS, OS and TW by a linear mixedeffects model. The result indicated at least one significant difference in mean concentrations between the groups (P < 0.05). The following post-hoc comparisons showed a significant difference between NS and TW (P = 0.019, Figure 1, panel A) . The combinations NS-OS (P = 0.073) and OS-TW (P = 0.56) did not differ significantly. Six different concentration patterns (designated A to F) were found by combinatorial analysis of the quantitative results (Figure 1, panel B ; six patients with ≤1 positive result are not shown). The most prevalent pattern was NS > OS > TW (14/28; 50%; pattern D), followed by TW > OS > NS (4/28; 14%, pattern B). NS yielded the highest concentration in 18 (56%), TW in 8 (25%) and OS in 6 (19%) of 32 patients (Table 2, Figure 1 , panel C). The subgroup of 21 patients, where all sample materials (including SA) were available, was analyzed separately. The diagnostic sensitivities were 76% for NS, TW and SA (16/21 positive, respectively) and 71% for OS (15/21 positive). The SARS-CoV-2 RNA load in saliva ranged from 0 (not detected) to 2.3 × 10 6 cp/mL (Table 2, Figure 2 ). The respective median concentrations in this subset were 7.3 × 10 3 cp/mL for OS, 4.1 × 10 3 for NS, 3.4 × 10 3 for SA, and 2.7 × 10 3 for TW. Log 10 -transformed SARS-CoV-2 RNA levels were compared between the four sample groups: NS, OS, TW and SA. No statistically significant difference was found (P = 0.31, LME model) and no posthoc comparisons were performed. In the combinatorial analysis, the most prevalent concentration patterns were NS > OS > TW > SA (4/15; 27%) and NS > OS > SA > TW (3/15; 20%). In this study, we (a) aimed to compare levels of SARS-CoV-2-specific RNA derived by three sampling methods: throat washings (TW), nasopharyngeal swabs (NS) and oropharyngeal swabs (OS). Our results showed significantly higher concentrations in NS as compared to TW, but NS-OS and OS-TW did not differ significantly. The highest diagnostic sensitivities were found for NS and TW (85%), followed by OS (79%). Moreover, we (b) investigated saliva (SA) in a subgroup analysis: TW, NS, OS and SA did not differ significantly. Our first finding of a significant difference between NS and TW is supported by RT-qPCR based quantitative analysis of SARS-CoV-2 RNA levels in 102 specimens from 34 hospitalized patients with COVID-19 and moderate disease intensity. Our second finding is based on data from a subgroup covering 84 specimens from 21 patients. The current standard for molecular COVID-19 diagnostics involves testing NS specimens by RT-qPCR. Other specimens have been investigated in previous studies. Guo et al. found TW to be significantly superior to NS in paired samples [8] . These authors proposed TW as a promising candidate for SARS-CoV-2 screening and monitoring due to its noninvasiveness and reliability. However, the limitations of this study were the small sample size (7 patients) and a sampling time long after symptom onset (median 53 days, range 48-57 days), which might have contributed to the low positive detection rate. The results of our study do not confirm that TW is superior to NS. We found the median concentration of NS being 13-times (1.1 log 10 ) higher than in TW. This difference could-at least partially-be due to the higher volume (10 mL) of TW samples and the resulting dilution. In line with this observation, our data also suggest the use of NS samples as preferential material for antigen testing, which requires higher viral loads for detection. Wyllie et al. investigated saliva as an alternative to standard NS specimens [2] . These authors detected more SARS-CoV-2 RNA copies in the saliva than in the NS specimens (70 patients; mean 3.8 × 10 5 vs. 8.5 × 10 4 cp/mL). They conclude that saliva and NS have at least similar sensitivity in the detection of SARS-CoV-2 during the course of hospitalization. The results of our study do not confirm this observation. In contrast, we found virtually the same median viral load from NS samples compared to SA (4.1 × 10 3 vs. 3.4 × 10 3 cp/mL; 1.2-times higher = 0.1 log 10 ) in a subset of 21 patients. Variations in nasopharyngeal sampling may be an explanation for this discrepancy: The study by Wyllie et al. included NS collected by many health professionals while in our study all samples were collected by a single trained infectious disease specialist. In this context, a recently published study by Jamal et al. [3] reported a lower diagnostic sensitivity of SA (72%) as compared to NS (89%). It is an ongoing matter of debate, if collecting combined OS-NS or OS-nares samples [9, 10] can improve the positive detection rate. Our study did not address this question directly, but the quantitative comparison of NS and OS per patient revealed a higher concentration of OS specimens in 10 of 34 (29%) patients. It could be speculated whether collecting a combined specimen has the potential to improve the diagnostic sensitivity as compared to NS alone. There are some limitations to our study. First, we investigated adult COVID-19 patients with moderate disease from a non-intensive care medical ward. Therefore, our results may not be fully transferable to other groups, like children, outpatients or critically ill patients. However, we assume a comparable situation in adult outpatients with early disease stages, because the mean time since symptom-onset was only ∼6 days in our study. Second, only one nostril was probed for collecting NS, which might have negatively influenced the analytical sensitivity. Third, the collection of specimens took place between April and December 2020 in Southern Germany. The spectrum of circulating SARS-CoV-2 strains likely has changed since that time and we cannot exclude potential effects on the results. In conclusion, our study found the highest SARS-CoV-2 RNA concentrations in NS and comparable diagnostic sensitivities in all sampling groups. Our demonstration of only moderately lower viral loads in OS and TW indicates that they can be considered as alternatives for SARS-CoV-2 diagnostics instead of NS-which are more difficult to obtain, often not tolerated well by patients and affected by global supply shortages. Fur-thermore, TW could allow patient self-sampling, thereby reducing the risk of infection for medical personnel. Informed Consent Statement: Informed consent was obtained from all subjects involved in the study. The data generated for this publication have been included in the current manuscript. The authors wish to thank the Virology Molecular Diagnostics team at the Institute of Clinical Microbiology and Hygiene, University Medical Center Regensburg, for expert technical assistance. The authors are also grateful to Florian Zeman for advice on the linear mixedeffects model. Hitzenbichler received payments for lectures by MSD Sharp and Dohme and travel grants by Gilead Sciences. Salzberger received payments for lectures by Falk Foundation and consulting fees by Sanofi and GSK. These companies had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results. The following abbreviations are used in this manuscript: SARS-CoV-2 viral load is associated with increased disease severity and mortality Saliva or Nasopharyngeal Swab Specimens for Detection of SARS-CoV-2 Sensitivity of Nasopharyngeal Swabs and Saliva for the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 Detection of SARS-CoV-2 in Different Types of Clinical Specimens Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR Library of prefabricated locked nucleic acid hydrolysis probes facilitates rapid development of reverse-transcription quantitative real-time PCR assays for detection of novel influenza A/H1N1/09 virus A new method of classifying prognostic comorbidity in longitudinal studies: development and validation Effect of Throat Washings on Detection of 2019 Novel Coronavirus Combined oropharyngeal/nasal swab is equivalent to nasopharyngeal sampling for SARS-CoV-2 diagnostic PCR A combined oropharyngeal/nares swab is a suitable alternative to nasopharyngeal swabs for the detection of SARS-CoV-2