key: cord-0949374-3fr9mvv7 authors: Ibáñez-Cervantes, G.; Lugo-Zamudio, G.E.; Cruz-Cruz, C.; Durán-Manuel, E.M.; Bravata-Alcántara, J.C.; García-Moncada, E.; Mata-Rocha, M.; Delgado-Balbuena, L.; Cureño-Díaz, M.A.; Ramírez-Cortina, C.R.; León-Ávila, G.; Nogueda-Torres, B.; Hernández-Hernández, J.M.; Rodil, S.E.; Bello-López, J.M. title: Ozone as an alternative decontamination process for N95 facemask and biosafety gowns date: 2022-03-15 journal: Mater Lett DOI: 10.1016/j.matlet.2021.131554 sha: 5c37f945b81fb3cc3e26a79089cc275d43d1c43b doc_id: 949374 cord_uid: 3fr9mvv7 COVID-19 pandemic created a global shortage of medical protective equipment. Here, we considered ozone (O(3)) a disinfectant alternative due to its potent oxidative activity against biological macromolecules. The O(3) decontamination assays were done using SARS-CoV-2 obtained from patients to produce artificial contamination of N95 masks and biosecurity gowns. The quantification of SARS-CoV-2 was performed before and after exposing the samples to different ozone gas concentrations for times between 5 and 30 min. Viral loads as a function of the O(3) exposure time were estimated from the data obtained by the RT-PCR technique. The genetic material of the virus was no longer detected for any tested concentrations after 15 min of O(3) exposure, which means a disinfection Concentration-Time above 144 ppm min. Vibrational spectroscopies were used to follow the modifications of the polymeric fibers after the O(3) treatment. The results indicate that the N95 masks could be safely reused after decontamination with treatments of 15 min at the established O(3) doses for a maximum of 6 cycles. G. Ibáñez-Cervantes* 1 , G.E. Lugo-Zamudio* 1 3 Hospital de Pediatría, Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Ciudad de México. 4 Departamento de Energía, Universidad Autónoma Metropolitana, Ciudad de México. 5 Departamento de Zoología, Escuela Nacional de Ciencias Biológicas, IPN, Ciudad de México. 6 Departamento de Parasitología. Escuela Nacional de Ciencias Biológicas, IPN, Ciudad de México. 7 Keywords: Ozone, decontamination; SARS-CoV-2; protective equipment; COVID-19 The shortage of medical protective equipment (PPE) observed during the recent acute respiratory syndrome coronavirus outbreak (SARS-CoV-2) [1] [2] [3] [4] [5] limited its distribution to the hospital personnel leading to a high percentage of infected personnel worldwide [6] . One possible stratagem for mitigating the demand for PPEs (N95) is their reuse after adequate decontamination. The decontamination process needs to be easy to implement, safe, able to inactivate any potentially infectious material on their surfaces, and preserve the materials' filtration capabilities. Different methods have been proposed to achieve the proper decontamination of N95 [7] [8] [9] [10] [11] [12] [13] [14] [15] facemasks, but few have been officially approved [16] [17] [18] . Ozone (O 3 ), which has a strong oxidation potential and documented antimicrobial properties [19] [20] [21] [22] [23] [24] , has not been widely used [25] , and it could be a simple alternative for decontamination. However, considering that the PPEs are composed of 4-6 layers of non-woven polymeric fibers and polymers are degraded by oxidative species, such as O 3 [26, 27] , the integrity of the materials should be evaluated. This work aimed to demonstrate whether O 3 can be used as a disinfectant for high-demand PPEs and determine their lifetime based on the evaluation of the molecular integrity of the polymers using vibrational techniques. Circles (1 cm in diameter) of the outer surface of N95 and biosafety gowns (B.G.) were inoculated with 50 L of SARS-CoV-2 diluted in viral preservation media (DOUBANG TM disposable, Biocomma at 1:1, 1:10, 1:100, 1:1000, and 1:10000). Subsequently, inoculums were incubated at room temperature for 40 min for their total absorption in the materials. This artificial contamination test simulates a "real" contamination situation through bioaerosols since health personnel is exposed to them during the management of COVID-19 patients. Decontamination assays were performed using a portable O 3 generator. The samples were placed in a stainless-steel tray and were introduced in an airtight glass chamber 8 mm thick with a 15.6 L capacity kept at room temperature (25 °C). Ozone was injected through a 4.8 mm internal diameter hose at different exposure times (5, 10, 15, and 30 min) using a constant dose of 600 mg/h. Assuming an uniform distribution of the gas, the O 3 concentrations achieved in the chamber after the injection times are 3.2, 6.4, 96 and 19.2 ppm, respectively. A glass Petri dish with gauze soaked with sterile distilled water was introduced to maintain a humid environment (40% R.H.) inside the chamber. Atmospheric oxygen was injected using a fish tank pump during the same exposure times for the control group. Control and contaminated samples were subjected to detection of SARS-CoV-2 using RT-PCR to quantify viral loads. The molecular integrity of the polymeric materials was evaluated using Raman and FTIR as a function of O 3 exposure time and compare with an estimate of the filtration efficiency (F.E.) [28] . More experimental details are in the supplementary file. (Table S1 ). Nevertheless, the PRV is above 95 %. This simulated contamination experiment allows us to determine that 15 min of exposure or "Concentration x Times (CT)" [29] above 144 ppm min were sufficient to accomplish the undetectability of SARS-CoV-2 even at the highest viral concentrations. These CT values are larger than those reported for viral disinfection experiments of water [30] , but much lower than when ozone gas is tested for room decontamination using surrogate viruses (4800 ppm min) [31] . Figures 2A and B show the Raman and FTIR spectra of the N95 masks, respectively, including the lines from the P.P. reference spectra [26] . For the PP, the degradation is characterized by changes in the hydroxyl (OH) (3400 cm -1 ), carbonyl (C=O, 1650-1850 cm -1 ), and unsaturated (C=C) groups (890 and 1648 cm -1 ) [26, 27] . Figures 2A and B indicate no significant degradation of the P.P. fibers at shorter exposure times. However, the appearance of the carbonyl group signal in the FTIR spectra for the samples treated at 120 (8 cycles) and 180 min indicate the outset of degradation [32] [33] [34] [35] . scission [36] . Figure 2D shows the FTIR spectra of the B.G. samples that did not show any signs of degradation, probably because it was a single P.P. layer. of the elastic straps remain nearly unchanged for treatment times below 120 min. Above this time,  max and  increased, which means more extensive deformation for the elastic straps exposed to 8 -O 3 cycles for the same applied strength. Such extensive deformation damages the fitting of the facemask, suggesting that less than 8 disinfection cycles should be used. Kumar et al. [15] compared different disinfection methods, finding that FE is less prone to failures than the fitting test. The microbiological evidence indicated that the use of O 3 (144 ppm min) is an alternative for decontamination for polypropylene-based N95 masks and biosafety gowns. The results showed that the N95 facemask could stand the O 3 treatment up to 120 min (8 cycles), but taking a safe margin; we suggest that the N95 masks could be reused up to 6 cycles. The F.E. approximate test data indicates that the number of recommended cycles is consistent with those reported by the FDA for the approved decontamination tests. "Sistema Nacional de Investigadores (SNI)" from CONACyT. Projects CONACyT 313771 and SECTEI 096/2020. Effective decontamination of N95 facemasks contaminated with SARS-COV-2 Ozone degradation of polypropylene fibers used in facemasks The mechanical properties of elastic bands were affected after 120 min of O 3 exposure, The propylene fibers of the N95 show signs of degradation after 120 min of O 3 exposure. Options for the decontamination and reuse of respirators in the context of the COVID-19 pandemic FDA, Decontamination System EUAs for Personal Protective Equipment Infrared and Raman spectroscopy of polypropylene Oxidative Degradation of Polymers in Presence of Ozone Investigation, C. Cruz-Cruz: Investigation, E.M. Durán-Manuel: Investigation, J.C. Bravata-Alcántara: Investigation, E. García Moncada: Investigation, M. Mata-Rocha: Investigation, L. Delgado-Balbuena: Investigation, M.A. Cureño-Díaz: Investigation, C.R. Ramírez-Cortina: Investigation, G. León-Ávila: Investigation, B. Nogueda-Torres Rodil: Investigation, Writing