key: cord-0949096-18g9udnr authors: Berger, Alice; Nsoga, Marie Therese Ngo; Perez-Rodriguez, Francisco Javier; Aad, Yasmine Abi; Sattonnet-Roche, Pascale; Gayet-Ageron, Angèle; Jaksic, Cyril; Torriani, Giulia; Boehm, Erik; Kronig, Ilona; Sacks, Jilian A.; de Vos, Margaretha; Bausch, Frédérique Jacquerioz; Chappuis, François; Renzoni, Adriana; Kaiser, Laurent; Schibler, Manuel; Eckerle, Isabella title: Diagnostic accuracy of two commercial SARS-CoV-2 antigen-detecting rapid tests at the point of care in community-based testing centers date: 2021-03-31 journal: PLoS One DOI: 10.1371/journal.pone.0248921 sha: 197a848ad54d4071e72b100b6a10d6590a00a141 doc_id: 949096 cord_uid: 18g9udnr OBJECTIVES: Determine the diagnostic accuracy of two antigen-detecting rapid diagnostic tests (Ag-RDT) for SARS-CoV-2 at the point of care and define individuals’ characteristics providing best performance. METHODS: We performed a prospective, single-center, point of care validation of two Ag-RDT in comparison to RT-PCR on nasopharyngeal swabs. RESULTS: Between October 9(th) and 23(rd), 2020, 1064 participants were enrolled. The Panbio(TM) Covid-19 Ag Rapid Test device (Abbott) was validated in 535 participants, with 106 positive Ag-RDT results out of 124 positive RT-PCR individuals, yielding a sensitivity of 85.5% (95% CI: 78.0–91.2). Specificity was 100.0% (95% CI: 99.1–100) in 411 RT-PCR negative individuals. The Standard Q Ag-RDT (SD Biosensor, Roche) was validated in 529 participants, with 170 positive Ag-RDT results out of 191 positive RT-PCR individuals, yielding a sensitivity of 89.0% (95%CI: 83.7–93.1). One false positive result was obtained in 338 RT-PCR negative individuals, yielding a specificity of 99.7% (95%CI: 98.4–100). For individuals presenting with fever 1–5 days post symptom onset, combined Ag-RDT sensitivity was above 95%. Lower sensitivity of 88.2% was seen on the same day of symptom development (day 0). CONCLUSIONS: We provide an independent validation of two widely available commercial Ag-RDTs, both meeting WHO criteria of ≥80% sensitivity and ≥97% specificity. Although less sensitive than RT-PCR, these assays could be beneficial due to their rapid results, ease of use, and independence from existing laboratory structures. Testing criteria focusing on patients with typical symptoms in their early symptomatic period onset could further increase diagnostic value. a1111111111 a1111111111 a1111111111 a1111111111 a1111111111 The Coronavirus Disease 19 pandemic, caused by SARS-CoV-2, has led to an unprecedented public health crisis. Diagnostic strategies that are low cost, rapid, and easily accessible are critical to control the pandemic. While RT-PCR based assays remain the standard for the detection of emerging respiratory viruses [1, 2] , the need for high through-put virus detection has fueled development of Antigen-detecting rapid diagnostic tests (Ag-RDT), that can be performed at the point of care (POC) [3] . Such laboratory-independent tests could allow for control of the pandemic by quickly isolating individuals during their contagious period to prevent further transmission. These tests can affordably help overcome overwhelmed diagnostic laboratories and global PCR-reagent shortages [4, 5] . Given that viral load, as measured by RNA copies, peaks near symptom onset [6] [7] [8] and contagiousness begins even earlier [9, 10] , RDTs may have the highest sensitivity (SN) in the most contagious individuals. Reported SNs of Ag-RDTs vary widely, and manufacturer reported SNs are often substantially higher than those of independent assessments [11] . Previous studies with NPS rapid antigenic tests (Panbio) for detection of SARS-CoV-2 shows the sensitivity of 95% for Ct �25, and 85% for Ct <30 in symptomatic patients and the sensitivity near of 80% for a period of less than 7 days from symptom onset but the overall sensitivity in this population seems low at 67.3% [12] . A study on two NPS RDT (Panbio and SD Biosensor) versus PCR in symptomatic population found an overall sensitivity of 73.8% and 68.5%; for a CT value< 30, sensitivities of two RDT are respectively 87% and 81.4% in a population with mostly symptomatic patients [13] . Lambert-Niclot et al. found a sensitivity of 50.0% with RDT NPS (Respi-Strip) versus PCR and for the CT value <25CT, sensitivity was 82.2% [14] . The World Health Organization's (WHO) Ag-RDT target product profile aims at SNs �80% and specificities (SP) of �97% [5, 15] . Thus, we sought to evaluate the performance of two commercially available Ag-RDTs through a prospective, single-center POC validation in comparison to RT-PCR for detecting SARS-CoV-2 using nasopharyngeal swabs (NPS). We evaluate also the performance of these tests according to the duration of symptoms and viral loads of patients mostly symptomatic. The study was approved by the Cantonal ethics committee (Nr. 2020-02323). All study participants and/or their legal guardians provided written informed consent. HUG (https://www.fondationhug.org/) and Pictet Charitable Foundation (https://www.group.pictet/ responsible-vision/pictet-group-foundation). M.T. Ngo Nsoga is a beneficiary of the excellence grant from the Swiss confederation (https://www.sbfi. admin.ch/sbfi/en/home/education/scholarshipsand-grants/swiss-government-excellencescholarships.html) and the grant from the humanitarian commission of the university hospitals of Geneva (https://www.hug.ch/en/ external-affairs-directorate). The Foundation for Innovative New Diagnostics provided rapid tests and elements of the study protocol. The funders had no other roles in study design, data collection and analysis, decision to publish, or preparation of the manuscript. The authors have declared that no competing interests exist. The study was performed in two geographically different testing centres run by our institution, the Geneva University Hospital. Both centres are supervised by the same team, and did not differ in their infrastructure, so we analyzed them as a single centre study. The primary objective of this prospective study was to assess the diagnostic accuracy (SN and SP) of the Ag-RDTs compared to the reference RT-PCR. Participants were �16 years old, with suspected SARS-CoV-2 infection according to the local governmental testing criteria. This included suggestive symptoms for COVID-19 and/or recent exposure to a SARS-CoV-2 positive person. Asymptomatic individuals were included if they were notified by the Swiss COVID-19 app or by local health authorities after contact to a confirmed case. For each participant, two NPS were collected. The first was a standard flocked swab placed in viral transport media (VTM), used routinely for viral genome detection by RT-PCR. The second NPS, provided in the Ag-RDT kit, was obtained from the contralateral nostril and was performed as recommended by the manufacturer. Both swabs were taken by the same trained nurse. All Ag-RDTs were performed immediately at the sample collection site. Adequate personal protective equipment was used while collecting the NPSs and performing the RDTs. Clinical data were collected for each patient upon presentation with a questionnaire including the number of days post symptom onset (DPOS), known contact to a previous SARS-CoV-2 infected person, comorbidities and type of symptoms. The following symptoms were recorded: rhinorrhea (runny nose), odynophagia, myalgia, chills, dry cough, productive cough, red expectoration, fever (anamnestic), anosmia/ageusia (loss of smell or taste), gastrointestinal symptoms, asthenia, dyspnea, thoracic pain and headache. Comorbidities included in the questionnaire were hypertension, cardiovascular disease, chronic pulmonary disease, diabetes, chronic renal failure, active cancer including lymphoproliferative disease, severe immunosuppression, immunosuppressive therapy, pregnancy, and obesity (BMI >40 kg/m 2 ). The two validated Ag-RDTs were Panbio TM COVID-19 Ag Rapid Test Device (Abbott Rapid Diagnostics, US) and Standard TM Q COVID-19 Ag Test (SD Biosensor, distributed by Roche, Switzerland). Both Ag-RDTs were used as recommended by the manufacturers, using only materials provided in the kit. Both assays were manually read, with two individuals reading the results separately. In case of discordant results, the two validators sought a consensus. All visible bands were considered a positive result. All Ag-RDT results were photographically documented. All participants were tested by a single well, dual target RT-PCR assay for SARS-CoV-2 (cobas1 SARS-CoV-2 Test, Cobas 6800, Roche, Switzerland) using NPS in 3mL VTM. For further analysis, only cycle threshold (Ct) values for the E-gene were used. For calculation of viral loads (VL) as SARS-CoV-2 genome copy numbers per mL, a standard curve was obtained by using a quantified supernatant from a cell culture isolate of SARS-CoV-2. All VLs were calculated from the Ct-values, according to log10 SARS-CoV-2 RNA copies/ml = (Ct-44.5)/-3.3372 for Cobas [16, 17] . Over a 2-week period, we enrolled all patients who met the SARS-CoV-2 testing criteria; 535 and 529 patients were enrolled during the first and second week, respectively. The target sample size was 530, as it would have sufficient power to generate a 95% confidence interval (CI) with a lower bound above the WHO target of 80%, if the prevalence was 25% and the measured SP was �87.5%. All continuous variables were presented by their mean ±standard deviation (SD) and median (interquartile range, IQR), categorical variables were presented by their frequencies and relative proportions. For comparisons of continuous variables, we used a nonparametric Mann-Whitney test due to small sizes; for comparisons of categorical variables, we either performed Chi 2 or Fischer's exact tests, depending on applicability. To enable Ag-RDT result combination, we performed a Bayesian t-test on their sensitivities and specificities. To be able to conduct the t-test, the confidence intervals of both sensitivities and specificities were converted into standard deviation to allow for the t-test to be conducted. The test computes a Bayesian Factor (BF) that allows comparison of the probability of observing our data under H 0 (both tests are equal in term of SN and SP) and H 1 (both tests are different). All analyses were performed using STATA version intercooled 16 (Stata Corp., College Station, TX, USA). Statistical significance was defined as p<0.05 (two-sided). Between October 9 th and October 23 rd , 2020, 1064 participants were enrolled and included in the analysis. 535 participants were tested with the Panbio Ag-RDT from October 09 th to 16 th and 529 participants were tested with the Standard Q Ag-RDT from October 19 th to 23 rd , 2020. Characteristics of the study population are shown in Table 1 . The mean age of the study participants was 34.9 years (SD ±10.9) with 53.8% being female. The mean DPOS to testing was 2.7 (SD ±1day). Overall, 29.6% of participants were positive by RT-PCR with a mean Ctvalue of 22.5 (SD ±5.1), corresponding to a VL of 1.8E7 SARS-CoV-2 copies/mL. Most patients Table 2 ). The absolute numbers of positive and negative detections per method (by RT-PCR and Ag-RDT) and number of true positive, false negatives, false positives and true negatives can be found in Table 3 . Ct (Fig 1) . Furthermore, we evaluated overall Ag-RDT results in relation to Ct-values/viral load as well DPOS (Fig 2) . False-negative results occurred in both assay across all DPOS. We compared SN and SP between the two Ag-RDTs and concluded that we could accept, with high probabilities, (respectively likelihood ratio of BF 01 = 10.2 and 11.9) the hypothesis of equivalent SN and SP. Based on this, a combined SN of 87.6% (95%CI: 83.5-91.0) and a combined SP of 99.9% (95%CI: 99.3-100) for both Ag-RDTs were calculated with a positive predictive value of 99.6% (95%CI: 98.0-100) and a negative predictive value of 95.0% (95%CI: 93.3-96.5). In order to identify subpopulations in which maximal SN could be reached with these tests, we analyzed SN by DPOS, Ct-values as determined by RT-PCR, type of symptoms, comorbidities, and previous contact with a confirmed SARS-CoV-2 infection. Table 3 . RT-PCR and Ag-RDT results. 8) for Ct �20 (�1.0E8 SARS-CoV-2 copies/mL), decreased slightly to 95.5% (95%CI: 89.9-98.5) for 20 < Ct �25 (<1.0E8 SARS-CoV-2 copies/ mL � 3.2E6), dropped further to 89.9% (95%CI: 86.0-93.0) for Ct �35 (�3.2 E3 SARS-CoV-2 copies/mL) and was lowest (only 40.9% (95%CI: 20.7-63.6)) for 30< Ct �35 (<1.0E5 SARS--CoV-2 copies/mL �3E3) (Fig 3) 6-98.9) , with a decline after 5 DPOS (Fig 4A) . Diagnostic accuracy of two SARS-CoV-2 rapid tests at the point of care Additionally, we analyzed SN according to specific symptoms, differentiating between typical COVID-19 symptoms (fever/chills, cough and anosmia/ageusia) and more non-specific symptoms of respiratory infection (all other symptoms reported). The highest SN of 93.8% (87.0-97.7) was observed for patients presenting with fever/chills and cough at the time of testing, followed by patients presenting with anosmia/ageusia or cough and fever/chills with a SN of 93.7% (95%CI: 87.4-97.4), but only 73.8% (95%CI: 58.0-86.1) in patients presenting with non-specific signs (Fig 4B) . No difference in SN was seen between patients with (89.3%, 95% CI: 71.8-97.7, n = 28) or without (87.5%, 95%CI: 83.1-91.1, n = 287) comorbidities (p = 0.999). Typical symptoms were more frequent in patients with comorbidities (100%, 15/ 15 patients) than in patients without comorbidities (86.5%, 96/138 patients) (p = 0.012), however sample size was small. No difference was seen in patients with or without contact with a recently positive case (p = 0.065). We further analysed by DPOS, and found that the highest SN was seen in patients with fever/chills and presenting between 1 and 5 DPOS, at 95.7% SN (95%CI: 91.0-98.4). This study provides an independent, POC validation of two commercial Ag-RDTs relative to RT-PCR and according to demographic and clinical information. This combined validation of two similar assays provides performance data in a real-life high incidence test setting. Both RDTs performed well with an overall SN of 87.6% (95%CI: 83.5-91) and a very high SP of 99.9% (95%CI: 99.3-100) during a time of very high SARS-CoV-2 weekly incidence (375/100,000 to 824/100,000 inhabitants) and a SARS-CoV-2 RT-PCR positivity rate >20%. SN was higher in sub-populations with earlier DPOS numbers and characteristic COVID-19 symptoms. Importantly at 0 DPOS, the SN is lower than during the subsequent days, and the sensitivity drops rapidly when the Ct-values increase above a threshold of 30, mostly after 6-7 days. The highest VL and thus transmission probability occurs within the first week of symptom onset, with VLs peaking around the time of symptom onset [6] . Culturable virus has been predominantly found in the first week after symptom onset, down to a VL around 1E6 copies/ml [17] [18] [19] [20] , which has been set as a detection cut-off for Ag-RDTs by the WHO [15] . The SN of the Ag-RDTs validated here, for VLs compatible with contagiousness, was 95.7%. Correspondingly, the highest Ag-RDT SN was also observed at early DPOS numbers and in patients with low Ct-values, again suggesting reliable identification of contagious individuals. Our findings at the POC are in line with other validations performed in different countries and prevalences, although study designs and specimens used varied considerably between studies. Standard Q was reported to have SNs between 70.6-88.7%, while SP remained high throughout these studies between 97.6-100% [21] [22] [23] [24] [25] [26] [27] . A clinical study performed similarly to ours in a much lower-incidence setting (<1% RT-PCR positivity rate), found a SN/SP of 76.6%/100%, using a mixture of NPS and combined oro-and naso-pharyngeal swabs from a total of 2417 participants with 47 RT-PCR positive samples yielding 36 Ag-RDT [21] . For Panbio, other studies have reported SNs ranging from 73.3-91.7% with SP in the range of 94.9-100% [28] [29] [30] [31] . Notably, the highest reported SN of 91.7%/98.9% comes from a study, not done at a POC, using frozen NPS specimens [28] . Although the use of frozen samples is possible for RDTs [22, 28] , it is not their intended use and does not represent their use in the field. It is also unknown if a freeze-thaw cycle can affect the accessibility of viral antigens. While significant variation in Ag-RDT SN is observed across studies, there is remarkable similarity within certain Ct-value ranges-although caution must be exercised comparing Ctvalues of different assays. For Ct-values of <25, the Standard Q test was reported to have a SN of 100% [21] , while the Panbio was reported to have a SN of 97.1% [30] or 98.2% [28] , which is in agreement with our results of 97%. In contrast to most other validations, we did observe false-negative Ag-RDT results in patients with high VLs across a range of DPOS. These patients are likely contagious and able to transmit SARS-CoV-2, with VLs associated with culturable virus. We did not find any validation of Ag-RDTs that has analyzed SN based on type of symptoms, which could be an additional factor for testing algorithms. This finding also highlights that Ag-RDTs are a valid diagnostic tool in symptomatic individuals, while the benefit of their use in asymptomatic individuals or in patients with atypical or minor symptoms remains to be investigated. In a situation with sufficient RT-PCR capacity, testing algorithms focusing on a subgroup of symptomatic patients, while testing others with more sensitive RT-PCR might be an option to make the best use of Ag-RDTs. In our data set, the best SN is found in symptomatic individuals with symptoms suggestive of COVID-19, between 1 and 5 DPOS. Our study has several strengths. The Ag-RDTs were performed at the POC in parallel to RT-PCR, and is one of the largest in terms of RT-PCR positive individuals. The test population represents a population screened for public health intervention, and not for diagnostic purposes in a hospital setting: mainly young unhospitalized adults without comorbidities, who mostly had typical and mild COVID-19 symptoms. This currently describes the majority of SARS--CoV-2 infected individuals, and an important group for limiting community transmission. Although Ag-RDTs are less sensitive than RT-PCR and, we saw false-negative Ag-RDT results in patients with high VL, the public health benefit of quickly identifying a large proportion of infected individuals would still outweigh the disadvantages of occasional missed diagnoses [32] . Furthermore, our validation showed very high SP, with only one false-positive Ag-RDT result in the whole study. Interestingly, the patient with this putative false-positive tested positive 3 days later for SARS-CoV-2 by RT-PCR. This study was conducted in a high prevalence setting, thus extrapolating the findings of our study to low prevalence settings must be done with caution. In conclusion, we show good diagnostic accuracy of both Ag-RDTs, especially for rule-in purposes of infected individuals and in patients with certain criteria. The SN for identification of SARS-CoV-2 infections, rapidity of results, and the laboratory-independence make these Ag-RDTs promising tools for SARS-CoV-2 infection control. Detection of a novel human coronavirus by real-time reverse-transcription polymerase chain reaction Identification of a Novel Coronavirus in Patients with Severe Acute Respiratory Syndrome The explosion of new coronavirus tests that could help to end the pandemic Rethinking Covid-19 Test Sensitivity-A Strategy for Containment Antigen-detection in the diagnosis of SARS-CoV-2 infection using rapid immunoassays Temporal dynamics in viral shedding and transmissibility of COVID-19 SARS-CoV-2 Viral Load in Upper Respiratory Specimens of Infected Patients SARS-CoV-2 detection, viral load and infectivity over the course of an infection The Incubation Period of Coronavirus Disease 2019 (COVID-19) From Publicly Reported Confirmed Cases: Estimation and Application Inferred duration of infectious period of SARS-CoV-2: rapid scoping review and analysis of available evidence for asymptomatic and symptomatic COVID-19 cases Group TEC-19 microbiological laboratories. Meta-analysis of the clinical performance of commercial SARS-CoV-2 nucleic acid, antigen and antibody tests up to 22 Nasopharyngeal Panbio COVID-19 antigen performed at point-of-care has a high sensitivity in symptomatic and asymptomatic patients with higher risk for transmission and older age. Open Forum Infect Dis The sensitivity of SARS-CoV-2 antigen tests in the view of large-scale testing. medRxiv Evaluation of a Rapid Diagnostic Assay for Detection of SARS-CoV-2 Antigen in Nasopharyngeal Swabs COVID-19 Target product profiles for priority diagnostics to support response to the COVID-19 pandemic v.1.0 [Internet SARS-CoV-2 viral load in the upper respiratory tract of children and adults with early acute COVID-19 Culture-Competent SARS-CoV-2 in Nasopharynx of Symptomatic Neonates, Children, and Adolescents. Emerg Infect Dis Virological assessment of hospitalized patients with COVID-2019 Shedding of infectious virus in hospitalized patients with coronavirus disease-2019 (COVID-19): duration and key determinants. medRxiv Daily Viral Kinetics and Innate and Adaptive Immune Response Assessment in COVID-19: a Case Series Evaluation of the accuracy, ease of use and limit of detection of novel, rapid, antigen-detecting point-of-care diagnostics for SARS-CoV-2. medRxiv Urgent need of rapid tests for SARS CoV-2 antigen detection: Evaluation of the SD-Biosensor antigen test for SARS-CoV-2 Rapid chromatographic immunoassaybased evaluation of COVID-19: A cross-sectional, diagnostic test accuracy study & its implications for COVID-19 management in India. The Indian journal of medical research Evaluation of SD Biosensor, Inc. STANDARD TM Q COVID-19 Ag FIA External Report. 2020. FIND Rapid SARS-CoV-2 antigen detection assay in comparison with real-time RT-PCR assay for laboratory diagnosis of COVID-19 in Thailand Field Evaluation of the Performance of a SARS-CoV-2 Antigen Rapid Diagnostic Test in Uganda using Nasopharyngeal Samples Real-life validation of the Panbio TM COVID-19 antigen rapid test (Abbott) in community-dwelling subjects with symptoms of potential SARS-CoV-2 infection Analytical and clinical performance of the panbio COVID-19 antigen-detecting rapid diagnostic test Field evaluation of a rapid antigen test (Panbio TM COVID-19 Ag Rapid Test Device) for COVID-19 diagnosis in primary healthcare centres Panbio antigen rapid test is reliable to diagnose SARS-CoV-2 infection in the first 7 days after the onset of symptoms Evaluation of the Panbio Covid-19 rapid antigen detection test device for the screening of patients with Covid-19 Test sensitivity is secondary to frequency and turnaround time for COVID-19 surveillance We thank all nurses and staff at the testing Centre Sectors of our institution as well as the patients for their willingness to participate in the study. We thank Catia Machado-Delgado for excellent technical assistance and Stéphanie Baggio for help with data analysis.