key: cord-0948241-78vz3xra authors: Kreutzberger, Jürgen title: Protein microarrays: a chance to study microorganisms? date: 2006-04-01 journal: Appl Microbiol Biotechnol DOI: 10.1007/s00253-006-0312-y sha: 3a942ffca66d805f3b73c8ac7b71658ea081024d doc_id: 948241 cord_uid: 78vz3xra Within the last 5 years, protein microarrays have been developed and applied to multiple approaches: identification of protein–protein interactions or protein–small molecule interactions, cancer profiling, detection of microorganisms and toxins, and identification of antibodies due to allergens, autoantigens, and pathogens. Protein microarrays are small size (typically in the microscopy slide format) planar analytical devices with probes arranged in high density to provide the ability to screen several hundred to thousand known substrates (e.g., proteins, peptides, antibodies) simultaneously. Due to their small size, only minute amounts of spotted probes and analytes (e.g., serum) are needed; this is a particularly important feature, for these are limited or expensive. In this review, different types of protein microarrays are reviewed: protein microarrays (PMAs), with spotted proteins or peptides; antibody microarrays (AMAs), with spotted antibodies or antibody fragments (e.g., scFv); reverse phase protein microarrays (RPMAs), a special form of PMA where crude protein mixtures (e.g., cell lysates, fractions) are spotted; and nonprotein microarrays (NPMAs) where macromolecules other than proteins and nucleic acids (e.g., carbohydrates, monosaccharides, lipopolysaccharides) are spotted. In this study, exemplary experiments for all types of protein arrays are discussed wherever applicable with regard to investigations of microorganisms. Protein microarrays have been developed within the last 5 years using the knowledge and technical innovations developed for DNA microarrays. DNA microarray tech-nology has evolved, as a consequence to handle sets of thousands of probes from the huge sequencing programs, beginning with microbial genomes (Sanger et al. 1982; Fleischmann et al. 1995) and reaching the top with the mouse ) and the human (Venter et al. 2001) genomes. The technical aspect of miniaturizing traditional methods, such as Western-Blotting and protein dotting onto classical surfaces such as nitrocellulose and nylon membranes could be adapted to protein microarray technology. First protein arrays were constructed as high-density protein arrays to analyze protein expression cDNA libraries (Bussow et al. 1998) . These arrays bear the feature of high-density (112 spots/cm 2 ) but have a format of about 500 cm 2 , and therefore were called protein macroarrays. In this way, 27,648 E. coli clones were spotted in duplicate onto one 222×222 mm Nylon filter membrane (Hybond-N + , Amersham). Subsequently, protein-expression and the detection of recombinant expression products were performed directly on these filters, without further purification. In a further development of this high-density spotting, crude cell lysates or purified proteins were spotted onto PVDF filters cut to microscopic slide format. This way, protein microarrays were generated with a theoretical density of 300 spots/cm 2 . In this study, a detection limit could be reached for spotted GAPDH protein detected by a monoclonal anti-GAPDH antibody of 250 amol/spot, respectively, 10 pg/spot (Lueking et al. 1999) . A Short time later, two publications demonstrating the potential of protein microarrays to screen whole proteomes were presented. The first proteome wide-protein array was used to analyze protein-protein interactions of Saccharomyces cerevisiae proteins. This array consisted of 6,000 yeast transformants, each with one cloned ORF fused to an activation domain and screened with 192 different yeast proteins (Uetz et al. 2000) . This approach is from the technical aspect of in situ expression similar to the work of Bussow et al. (1998) . The second proteome wide protein microarray consisted of 5,800 unique yeast proteins on a modified microscopic slide, which bear all adjectives of a protein-microarray. With this array, they demonstrated the usability of protein microarray technology to screen for protein-protein interactions by identification of calmodulin-and phospholipid-binding proteins (Zhu et al. 2001) . While these exemplary studies belong to the group of protein microarrays (PMAs) discussed below, they represent pioneer works in the field of all protein microarrays. Protein microarrays (PMAs) PMAs are named after the spotted compound basically purified recombinant proteins or peptides. These components can be used for a broad range of applications and some of them are discussed in this section. A common application of PMAs is the detection of antibody reactions (e.g., serum screening), which was used in several applications for human , bacterial Steller et al. 2005) or plant proteins (Kersten et al. 2003) . The systematical search for antibody specificities and cross-reactivities, as done for eleven polyclonal and monoclonal antibodies on PMAs containing 5,000 yeast proteins is an alternative strategy (Michaud et al. 2003) . Furthermore, PMAs can be used for the high-throughput identification of kinase targets, to identify, e.g., potential substrates for, e.g., Arabidopsis thaliana mitogen-activated protein kinases (MPK). For this purpose, a novel method, allowing high throughput study of protein phosphorylation was used on a microarray including 1,690 nonredundant Arabidopsis proteins. Using a threshold-based quantification method to evaluate the microarray results, 48 potential substrates of MPK3, and 39 of MPK6 could be identified; of which, 26 are common for both kinases (Feilner et al. 2005) . Polypeptides, protein domains or in general not complete proteins can be spotted as well to generate PMAs. Peptide microarrays can be used for the detection of molecular interactions in cellular signal transduction (Stoevesandt et al. 2005) . Therefore, phosphorylated CD3ζ ITAM and the nonphosphorylated counterpart ITAM peptides were spotted onto silanizated glass surfaces and incubated with lysates of cells expressing a fusion protein of the interaction partner ZAP-70. Peptide microarrays were also used for simultaneous detection of pathogen infection. For this purpose, peptides, specific for hepatitis B and C viruses, human immunodeficiency virus, Epstein Barr virus, and syphilis were made functional by a glyoxyl group and anchored on the glass surface by site-specific α-oxosemicarbazene ligation. This combined assay displays high sensitivity and specificity (Duburcq et al. 2004) . Peptide microarrays are perfectly suited for epitope mapping of antibodies and antibody fragments: A set of peptides with N-and C-terminal truncations of the peptide of interest were spotted to aldehyde slides (Poetz et al. 2005) . The authors have introduced quantifier spots to perform a relative affinity ranking of recombinant Fab fragments. For this system, two spots are required: One spot contains the antigen, while the other a capture molecule, which recognizes the constant part of the Fab (Poetz et al. 2005) . Affinity values are calculated from both signal intensities using the ambient analyte assay conditions first defined by Ekins 1989. Reverse phase microarrays (RPMAs) Reverse phase microarrays (RPMAs) are a special form of PMA, because here, protein mixtures derived from cell or tissue lysates are spotted. This approach offered the possibility to analyze modified proteins, which can not be obtained from E. coli or yeast. The first RPMA was used to quantify the abundance of selected proteins during the progression of normal epithelium into prostate carcinoma (Paweletz et al. 2001) . Cancer profiling is a predominant application of RPMAs identifying, for instance, potential serum markers for colon cancer (Nam et al. 2003) . In this study, fractionated, solubilized proteins from the LoVo colon cancer cell line were arrayed and incubated with autoantibodies of the same patient. Subsequently, protein fractions were selected and the proteins within the fractions identified by MS analysis. Furthermore, RPMAs can be used to simultaneously monitor dynamics of the site-specific phosphorylation of signaling molecules during stimulation of Jurkat T-Cells (Chan et al. 2004) . The authors determined a dynamic range of four orders of magnitude with a detection limit of one protein in 10 5 to 10 6 lysate proteins. Reproducible protein quantification can be obtained by multiple replica and dilution series on the array (Mircean et al. 2005) . Until now, RPMAs for analyzing microorganisms have not been published, and RPMAs are discussed in more detail elsewhere (Hultschig et al. 2006 ). Antibody microarrays (AMAs) consists of antibodies or antibody fragments. They are used for, e.g., the identification of proteins and bacteria. For example, biotinylated capture antibodies are immobilized on NeutrAvidin-coated slides and after incubation with solutions containing toxins or bacteria, these are detected by subsequent incubation with fluorescently labeled secondary antibodies. The detection limits in the case of the tested cholera toxin, staphylococcal enterotoxin B, Ricin, and Bacillus globigii were as low as 8, 4, 10 ng/ml and 6.2×10 4 cfu/ml, respectively (Delehanty and Ligler 2002) . Furthermore, AMAs are useful tools for analyzing protein content, and its changes due to development, disease, signaling, and other factors. Such an analysis was performed with an AMA consisting of 224 different antibodies on a nitrocellulose-coated glass slide, probed with protein extracts of mouse F9 embryonic carcinoma cells stimulated to differentiate and 43 proteins were identified to be upregulated and a sensitivity of 3 ng/ml protein detection was reached (Kopf et al. 2005) . In a different study, 378 antibodies containing commercial microarray (BD Bioscience) was applied to profile the effect of OxLDL (oxidized low density lipoprotein) on human aortic smooth muscle cells. Out of the 298 detected proteins in the cell lysates, 54 were differentially expressed (Sukhanov and Delafontaine 2005) . Besides the antibodies, antibody fragments such as scFv's can be used to generate AMAs. However, although the approach is particularly interesting, the bottleneck in analyzing proteins and tissues is the availability of suitable antibodies. To overcome this bottleneck, in vitro selection methods such as phage display were implemented . To advance the effectiveness of the in vitro selection, scFv's can be spotted directly onto microarrays (Wingren et al. 2005) or analyzed by doublespotting the scFv directly onto the prior insolublezed target proteins (Angenendt et al. 2004 ). Besides proteins (or nucleic acids), other components can be spotted to surfaces that bind proteins or microorganisms. Although these are not protein microarrays, they are (Peluso et al. 2003) Here, some surfaces are listed with their classification and applications. NC nitrocellulose (Super Nitro, Telechem International, USA); NC FAST nitrocellulose coated FAST slides (Schleicher&Schuell, Germany); PS polystyrol; PMA protein microarray; AMA antibody microarray; RPMA reverse phase protein microarray; NPMA non-protein microarray; NAPPA nucleic acid programmable protein array nevertheless presented here because of their similar application possibilities. The first example is a NPMA containing carbohydrates, which was subsequently probed with different E. coli strains. E. coli cells were bound by adhesion to mannose spotted on the microarray. An advantage of this approach is the nondestructive nature of this technique because the microorganisms could be recovered and used for further investigations, e.g., antibacterial susceptibility or substrate acquisition tests. In this study, the bacteria were stained using a nucleic acid dye and routinely 10 9 E. coli cells were used for detection, but the limit observed was 10 5 -10 6 cells (Disney and Seeberger 2004) . Another example for a NPMA is a monosaccharide array for the detection of bacterial toxins. Arrays of N-acetyl galactosamine (GalNAc) or N-acetylneuraminic acid (Neu5Ac) derivates were immobilized on the surface and used as receptors. The bacterial toxins (cholera and tetanus) were bound specifically to the monosaccharides, whereas labeled cells of E. coli, Salmonella typhimurium, Listeria monocytogenes, or staphylococcal enterotoxin B were not bound. For both toxins, the limit of detection is around 100 ng/ml (Ngundi et al. 2005) . In another experiment, lipopolysaccharide (LPS) microarray were used for the detection of antibodies (Thirumalapura et al. 2005) . Therefore, LPS was isolated from different bacteria and immobilized on nitrocellulose-coated glass slides. The specificity of these LPS arrays was tested using four monoclonal antibodies against these bacteria and the detection limit for antibodies was 10 ng/ml. Besides the obvious advantages of protein microarrays, such as high-throughput, high-density, improved reproducibility, and low sample consumption, there are also some limitations and bottlenecks. In this part of the review, I discuss more general aspects applicable to all protein microarrays. The on demand availability of purified proteins is in the case, were hundred to thousands proteins should be spotted a major limitation. A very fascinating approach to circumvent this limitation was done by Ramachandran et al.(2004) . They have generated protein microarrays by printing cDNAs onto glass slides besides capture antibodies (anti-GST). After adding a cell-free expression system, the proteins were generated directly on the microarray and bound with the fused GST-part to the capture antibodies. The proteins could now be analyzed as in a conventional proteinmicroarray. They demonstrated the feasibility with specific antibody binding to distinct fusion proteins and to map pairwise interactions among 29 human DNA replication proteins (Ramachandran et al. 2004) . To circumvent purification it might be useful for some applications to spot unpurified proteins if possible. In a recent approach, a cellulose surface was used and proteins were bound indirectly via a cellulose binding protein (Ofir et al. 2005) . A further possibility to circumvent the limitation of availability of purified and/or modified proteins is the RPMA approach presented above. Proteins are, due to their composition from many different amino acids, a class of very heterogeneous macromolecules with variable properties. This makes it extremely complicated to find a common surface suitable for different proteins with a broad range in molecular weight and physico-chemical properties such as charge and hydrophobicity. Therefore, multiple surfaces have been developed during the last 5 years; some of them are listed in Table 1 with their applications. Thereby, it is not important if the binding is due to a covalent binding or a physical adsorption. Binding could be from chemical reactions or physical adsorption directly between the surface structures and the spotted molecule (protein/antibody), or indirectly by a linker molecule. This linker molecule can be part of the protein (fusion protein) or a separate molecule. To find a surface suitable for all spotted components in a project is a major challenge, and there is more than one recommendation to use a distinct surface, and only few publications are dealing with this aspect, globally. Most investigations are driven by a discrete scientific problem, and for this problem-optimized conditions for this special approach have been found to obtain results. From this reason, available data are often not conferrable because they are different in the spotted material (e.g., different proteins), in analytes (diverse sera, proteins), and are spotted on different surfaces, and processed under different conditions. However, the few systematic studies for finding optimal processing conditions and suitable surfaces (Angenendt et al. 2002 (Angenendt et al. , 2003a Gutmann et al. 2005) are often without a study-driven relevance. A further aspect is the orientation of spotted compounds. For some applications where sufficient amounts of reactive parts (e.g., antigenic epitopes or proteins on the surface of a spotted microorganism) are present, this aspect is of less relevance. For others, like quantitative analysis, enzymatic reactions, interaction studies, phosphorylations, or protein drug screens, it becomes of essential relevance because reactive sites of proteins are usually limited. The effect of randomly vs specifically oriented capture agents based on both full-sized antibodies and Fab fragments on two types of streptavidin-coated slides was studied (Peluso et al. 2003) . The orientation of capture agents increases the analyte-binding capacity up to 10-fold. By using surface plasmon resonance analysis, a dense monolayer of 90% active Fab fragments has been detected (Peluso et al. 2003) . This aspect has also been studied for enzymatic activity because activity can be completely lost or lowered (Cha et al. 2005) . A different approach is the linking of proteins to DNA-coated arrays mediated from PCR-amplified DNA to a GAL4 DNA binding domain . A new method for stable binding of proteins to a surface has recently been developed by linking proteins via a Leucine zipper . Therefore an elastin mimetic domain is covalently bound to an Octyltrichlorosilane surface by a photoreactive amino acid and UV irradiation, whereas the target protein is fused to the complementary leucine zipper helix. The strong noncovalent binding of the helices leads to effective immobilizing of the target protein. Sensitivity and specificity are also very important features which are linked to other parameters like signal to noise ratio, background, and binding of (serum)-proteins to the background. These parameters are not only influenced by the surface; processing and detection also affect them. The detection limit is a good way to measure parameter, but is in most cases only a value for a certain couple of action partners (e.g., protein-antibody), and often detected only for an individual experimental setup. Conventional detection methods for microarrays often use fluorescent dyes, which were detected by irradiation from a laser scanner. Detection methods are discussed intensively elsewhere (Espina et al. 2004; Feilner et al. 2004 ), while in this study, only new approaches should be pointed out to reach much higher sensitivities. With a special method called MIST (multiple spotting technique) (Angenendt et al. 2003a, b) , multiple spotting steps are performed successively to one position. In such an experiment, protein is spotted in the first spotting round, and after washing and blocking steps, the corresponding antibody was spotted in the second spotting round to the same position. By this technique, it is possible to perform an enzymatic reaction and reach with this approach an extremely high sensitivity of 60 ymol (10 −24 mol) because chemical reactions take place in small "reaction compartments" formed by droplets. Normally enzymatic reactions, producing soluble products, were not possible on conventional protein microarrays, as products could mix on the planar surface. A further technical approach for better sensitivity is the rolling circle amplification (RCA) (Lizardi et al. 1998) . The system requires the direct conjugation of the proteins to be analyzed with a label (e.g., biotin or digoxigenin). This label was detected by an antibody, which is bound to a primer. After hybridization of a circular DNA molecule, the primer is extended by a polymerase. For detection, fluorescently labeled oligonucleotides complementary to the elongated DNA were used. AMAs consisting of 84 distinct antibodies specific to serum proteins were used with detection via RCA, for protein expression profiling of lung cancer patients (Gao et al. 2005 ). a b c d e Fig. 1 Possible identification of microorganisms. Microorganisms (dark blue symbols) will be fixed directly to coated microarrays (possible species-specific monosaccharides; light green in a and b). Alternatively, microorganisms can be bound via species-specific antibodies (black Ys in c-e). Direct detection with species-specific labeled antibodies (black Ys in a and c), sandwich assays with species-specific antibodies (black Ys), and secondary labeled antibodies (brown Ys with red or green stars in b and d) could be performed. With the MIST technology (Angenendt et al. 2003a,b) , detection could be performed by using an antibody bound enzyme (blue circle bound to Ys) which activity converts a substrate (yellow) to a detectable product (green or red circle in e) Very important for use, e.g., in diagnosis is the stability of diagnostic protein microarray test systems. Two kinds of stability have to be distinguished: one is the stability of the surface itself, and the other is the stability of spotted proteins on these. In a stability analysis, different antibodies were spotted on four different surfaces and stored under two different conditions (4°C, dried or in blocking solution) over 8 weeks, without crucial differences (Angenendt et al. 2002) . A shelf life was detected of more than 1 year at 2-8°C for a RheumaChip, with 14 different autoantigens suitable for the simultaneous determination of the most significant autoantibodies associated with rheumatic diseases (Schulte-Pelkum et al. 2005) . With protein microarrays, multiple (up to several thousands) spotted compounds can be analyzed, but in most applications only with one single analyte or a mixture of few at one time. With multiplexing approaches, multiple analytes should also be investigated at the same time. Multiplexing is an aspect not important for all approaches, but for approaches where many probes should be screened (e.g., medical routine diagnosis), it becomes of tremendous importance. Recently, the aspect of multiplexing has been discussed in detail , pointing out two major strategies: One is the multiplexing by different fluorophores, but this approach enables multiplexing with the limitation of detectable labels on the microarray. This approach could be performed better with nonarray systems, like the LiquiChip system of Qiagen. The second approach is to perform multiplexing by compartmentation, with physical compartments as multiwell slides (from different manufactures) or nonphysical compartmentation by MIST (Angenendt et al. 2003a (Angenendt et al. ,b, 2004 . Besides the general applications of protein microarrays mentioned above, there are only a few publications dealing with microorganisms. In this section, some exemplary publications in the field of microbiology are presented, dealing with protein microarrays and possible detection methods are summarized in Fig. 1 . The first PMA used for serodiagnosis of infectious disease contained a dilution row of human IgG (2-50 pg) and IgM (0.4-8 pg), and antigens (50 pg) from Toxoplasma gondii, rubella virus, cytomegalovirus, and herpes simplex virus type I and II spotted on amino-silane-activated glass slides (Mezzasoma et al. 2002) . The analysis showed a linear detection of internal calibration curves (IgG and IgM) and antigens, respectively, and results similar to ELISA analysis. In my group, we have performed serum-screening experiments with serum probes from Meningitis patients on PMAs with 67 different recombinant Neisseria proteins. From these proteins coding from phase variable genes, 47 showed an immune response to at least one out of 20 patient sera. Nine proteins elicited an immune response in more than three patients, and the phase-variable opacity protein OpaV, showing responses in 11 patient sera. This is also an interesting aspect as this protein is annotated as a hypothetical protein with an authentic frameshift from the Neisseria genome. So protein microarray technology could be used to verify predictions from genome data (Steller et al. 2005) . Another bacterial PMA containing about 150 Yersinia pestis proteins was used to profile antibody responses in immunized rabbits. In this study, antibodies to 50 proteins could be detected. Out of these 11 proteins are F1 and V antigens to which the predominant antibody responses occurred. These identified targets could be used for further evaluation as candidates for vaccines and as diagnostic markers . PMAs for serum screening of bacterial proteins have been established as shown above, and the use of viral proteins instead of bacterial proteins is technically not a difference, and could be used for identification and classification of viruses. Recently, PMAs were used for investigation of a coronavirus, the severe acute respiratory syndrome coronavirus (SARS-CoV). An important step in the development of vaccines and of diagnostic markers is to profile the antibodies to individual proteins. In this study, 13 recombinant proteins associated with structural and putative uncharacterized proteins of the SARS-CoV were prepared and used for the generation of SARS-CoV PMA. These were subsequently screened with SARS patient sera for their IgG antibodies, and antibody reactions to some of these proteins could be observed and found in one immunogenic protein as a good vaccine candidate. Moreover, they identified potential diagnostic markers and could support a hypothesis for some of the proteins to be synthesized during virus cycle deduced from the presence of antibodies against these . A PMA/NPMA array, consisting of 54 different Mycobacterium tuberculosis antigens, was used for a serological tuberculosis (TB) assay (Tong et al. 2005) . This array consists of recombinant antigens, purified polysaccharides and lipopolysaccharides, oligosaccharides bound to bovine serum albumin, and antigens from fractionation of M. tuberculosis cells and culture fluids, spotted on epoxycoated slides. This array could be stored at 4°C for 7 weeks. One antigen, Ara6-BSA, discriminated well between TB and non-TB, whereas most antigens gave poor discrimination, due to E. coli protein contamination or lack of glycosylation in E. coli. In this review, protein microarray technology is presented from the beginning to recent applications. Protein microarrays were divided in the major groups of PMA, RPMA and AMA, and the NPMA approaches. Limitations of protein microarray technology and possible solutions are discussed, and the use of protein microarrays for studying microorganisms is pointed out. Until now, there are only limited advances in the identification of microorganisms using protein microarrays. A major limitation is, until now, the high detection limit that could be reached, but there has been some new technological advancement. Fortunately, there are some encouraging approaches in indirect identification of pathogenic interactions by identifying serum antibodies. But this is only the matter of time that protein microarrays and, here especially, antibody-microarrays will be used for identification. This will be done first for in vitro models, but the most important are the identification of pathogens in medical samples (e.g., stool, blood, other body fluids) and from environmental sources (e.g., soil, air filtrates). These two fields will benefit from the addressed problems from the personalized medicine as well as from aspects coming from bioterrorism. So, one could expect in the near future that protein microarrays will be established for many applications in microbiological investigation. Toward optimized antibody microarrays: a comparison of current microarray support materials 3D protein microarrays: performing multiplex immunoassays on a single chip Next generation of protein microarray support materials: evaluation for protein and antibody microarray applications Seeing better through a MIST: evaluation of monoclonal recombinant antibody fragments on microarrays Subnanoliter enzymatic assays on microarrays A method for global protein expression and antibody screening on high-density filters of an arrayed cDNA library Enzymatic activity on a chip: the critical role of protein orientation Protein microarrays for multiplex analysis of signal transduction pathways Development of a protein microarray using sequence-specific DNA binding domain on DNA chip surface A new polymeric coating for protein microarrays A microarray immunoassay for simultaneous detection of proteins and bacteria The use of carbohydrate microarrays to study carbohydrate-cell interactions and to detect pathogens Peptide-protein microarrays for the simultaneous detection of pathogen infections Multi-analyte immunoassay Protein microarray detection strategies: focus on direct detection technologies High-throughput identification of potential Arabidopsis MAP kinases substrates Proteomic studies using microarrays Whole-genome random sequencing and assembly of Haemophilus influenzae Rd Distinctive serum protein profiles involving abundant proteins in lung cancer patients based upon antibody microarray analysis Fast and reliable protein microarray production by a new drop-in-drop technique Protein microarrays for highly parallel detection and quantitation of specific proteins and antibodies in complex solutions Recent advances of protein microarrays Generation of Arabidopsis protein chips for antibody and serum screening Multiplex approaches in protein microarray technology Perspectives for systematic in vitro antibody generation Panorama Ab microarray cell signaling kit: a unique tool for protein expression analysis Protein array consisting of sol-gel bioactive platform for detection of E. coli O157:H7 Developing site-specific immobilization strategies of peptides in a microarray Protein microarray for profiling antibody responses to Yersinia pestis live vaccine Mutation detection and single-molecule counting using isothermal rolling-circle amplification Protein microarrays for gene expression and antibody screening A nonredundant human protein chip for antibody screening and serum profiling Printing proteins as microarrays for high-throughput function determination Antigen microarrays for serodiagnosis of infectious diseases Analyzing antibody specificity with whole proteome microarrays Robust estimation of protein expression ratios with lysate microarray technology Sequence interpretation. Functional annotation of mouse genome sequences Molecular profiling of the immune response in colon cancer using protein microarrays: occurrence of autoantibodies to ubiquitin C-terminal hydrolase L3 Detection of bacterial toxins with monosaccharide arrays Versatile protein microarray based on carbohydrate-binding modules Reverse phase protein microarrays which capture disease progression show activation of pro-survival pathways at the cancer invasion front Optimizing antibody immobilization strategies for the construction of protein microarrays Protein microarrays for antibody profiling: specificity and affinity determination on a chip Antibody responses to individual proteins of SARS coronavirus and their neutralization activities Self-assembling protein microarrays Macronanoporous silicon as a support for high-performance protein microarrays Nucleotide sequence of bacteriophage lambda DNA A chip for the detection of antibodies in autoimmune diseases Bacterial protein microarrays for identification of new potential diagnostic markers for Neisseria meningitidis infections Peptide microarrays for the detection of molecular interactions in cellular signal transduction Protein chip-based microarray profiling of oxidized low density lipoprotein-treated cells Lipopolysaccharide microarrays for the detection of antibodies A multiplexed and miniaturized serological tuberculosis assay identifies antigens that discriminate maximally between TB and non-TB sera A comprehensive analysis of protein-protein interactions in Saccharomyces cerevisiae The sequence of the human genome Microarrays based on affinity-tagged single-chain Fv antibodies: sensitive detection of analyte in complex proteomes Artificial polypeptide scaffold for protein immobilization Global analysis of protein activities using proteome chips Acknowledgements The author thanks Zoltán Konthur for the helpful discussion and critical reading of the manuscript. The author wants to thank the Deutsche Forschungsgemeinschaft (DFG SFB TR 19).