key: cord-0947131-mt3v8q9t authors: Walczak, Ryan; Arnold, Mark; Grewal, Jeewanjot; Yuan, Xiao; Suryadevara, Amar; Marzouk, Haidy title: Reusable vs disposable nasopharyngolaryngoscopes: Cost analysis and resident survey date: 2020-12-10 journal: Laryngoscope Investig Otolaryngol DOI: 10.1002/lio2.500 sha: c155b3a9dafb84b2afe78daf4fe5b540cce2be9e doc_id: 947131 cord_uid: mt3v8q9t OBJECTIVE: Assess the quality of a new disposable nasopharyngolaryngoscope (NPL) through resident feedback at multiple academic institutions and provide a cost analysis of reusable and disposable NPLs at a single academic center. STUDY DESIGN: An online survey was distributed to residents at institutions throughout the United States that have implemented use of a disposable NPL (Ambu aScope 4 Rhinolaryngo). SETTING: Cost analysis performed at a single academic center. Resident survey distributed to multiple residency programs throughout the United States. SUBJECTS AND METHODS: The survey collected demographic information and asked residents to rate the new disposable NPL and other reusable NPLs using a 5‐point Likert scale. A cost analysis was performed of both reusable and disposable NPLs using information obtained at a single academic center. RESULTS: The survey was distributed to 109 residents throughout the country and 37 were completed for a response rate of 33.9%. The disposable NPL was comparable to reusable NPLs based on ergonomics and maneuverability, inferior in imaging quality (P < .001), and superior in setup (P < .001), convenience (P < .001), and rated better overall (P < .04). The disposable NPL was found to be cheaper per use than reusable NPLs at $171.82 and $170.36 compared to $238.17 and $197.88 per use for the reusable NPL if the life span is 1 year and 5 years respectively. CONCLUSION: Disposable NPLs may offer an alternative option and initial feedback obtained from resident physicians is favorable. Cost analysis favors disposable NPLs as the cost‐effective option. LEVEL OF EVIDENCE: NA. Nasopharyngolaryngoscopy (NPL) is widely used within the field of otolaryngology and allows the operator the ability to fully evaluate the upper aerodigestive tract. It is an essential tool in the diagnosis of voice disorders, locating foreign bodies, diagnosis of head and neck cancers, evaluation of the acute airway, and evaluation of many other disorders of the upper aerodigestive tract. 1,2 NPL also has therapeutic uses including aiding in removal of foreign bodies, vocal cord injections, and use of laser to remove vocal cord lesions. 3 NPLs are used both in the clinic setting and within the hospital for inpatient and emergency department consultations. In between uses, the reusable NPL requires reprocessing given their exposure to blood, body fluids, and microorganisms to avoid cross-contamination and this process requires time and resources. 4 Similar to NPLs, bronchoscopes also require reprocessing between uses. In recent years, a single-use or disposable version of the bronchoscope has been introduced and is widely used in a variety of clinical settings, negating the need for reprocessing. Several studies have compared the cost of reusable bronchoscopes to disposable bronchoscopes. These studies have shown that the disposable bronchoscopes are comparable in cost to reusable bronchoscopes and that cost of reusable bronchoscopes depends on the initial purchasing cost of the bronchoscopes, cost of maintenance and repairs, the cost of reprocessing, and the number of uses of the bronchoscopes. [5] [6] [7] [8] Within the past year, a single-use or disposable version of the NPL has been produced and implemented at several institutions within the United States. Currently there is no study in the literature evaluating the cost of reusable NPLs compared to disposable NPLs. In addition, there is no published literature that evaluates resident feedback on the use of disposable NPLs. This study sought to provide a cost analysis of reusable NPLs at an academic center to be compared to the cost of disposable NPLs as well as obtain initial feedback from residents at institutions regarding disposable NPLs in comparison to reusable NPLs. A list of institutions with otolaryngology residency programs that had instituted use of the Ambu aScope 4 Rhinolaryngo was obtained from the Ambu Incorporation. The Ambu aScope 4 Rhinolaryngo is a disposable version of an NPL intended for single use and requires connection to an Ambu monitor for viewing with the capability to record and still-capture images during the procedure. The list included a total of nine institutions with otolaryngology residency programs. One of the institutions has residents from two separate residency programs rotate at the hospital. A survey was then designed to obtain feedback from residents including demographic information and feedback for both the disposable NPL and other reusable NPLs. The survey utilized a 3-point Likert scale rating to assess resident feedback on the ease of learning to use the NPLs. The survey utilized a 5-point Likert scale to assess resident feedback on imaging quality, maneuverability, ergonomics, setup, convenience, and overall ratings. Imaging was explained as the visual quality seen on screen or through the NPL. Maneuverability was described as the ease with which the NPL was passed through the upper aerodigestive tract and includes size and tip bending of the NPL. Ergonomics was described as feel of the NPL in the hands including weight, shape, and texture. Setup was described as the ease of setting up the NPL for use including connecting to a screen, focusing the NPL, and aligning the camera. Convenience was described as the ease of obtaining the NPL within the hospital along with necessary equipment, transporting the NPL and necessary equipment, and disposing of the NPL and necessary equipment following the procedure. A Web-based anonymous survey (www.surveymonkey.com) was created. IRB exemption was obtained from SUNY Upstate Institutional Review Board given that no patient information would be used. Information was obtained from the study institution for cost analysis of the reusable NPLs including the cost of the initial purchase of the NPLs and necessary equipment, number and cost of repairs in a yearlong span from October 1st, 2018 until September 30, 2019. In addition, the costs associated with reprocessing of the NPLs including staff wages, time, and materials were obtained. The cost of the disposable NPL and associated monitor was also obtained. To ascertain the number of uses of the NPLs, the medical record was queried utilizing keywords including nasopharyngolaryngoscopy and nasopharyngo-laryngoscopy from October 1st, 2018 until March 31st, 2019. These keywords were chosen based on medical record templates used for documenting the procedure. Next, the resulting list was cross-referenced with the patient charts to confirm the procedure was performed. This included only procedures performed within the hospital as consults or on admitted patients. It did not include outpatient procedures. The time frame was prior to implementation of the disposable NPL and therefore all procedures were performed using reusable Karl Storz NPLs. Information was then used to calculate the cost of an individual use of the reusable NPLs. The calculations are based in part on a similar study that compared the per-use cost of reusable and disposable bronchoscopes. 9 The initial cost, maintenance, and repair fees were totaled and a per- After emails were sent to 10 program directors and directly emailed to 99 residents at six institutions, the survey was distributed to a total of 109 residents and a total of 37 (33.9%) responses were collected. Six of the respondents indicated within the survey that they do not use the disposable NPL and did not complete the remainder of the survey. Therefore, 31 responses were included in data analysis. Demographic information of resident respondents can be seen in The cost analysis for both the reusable and disposable NPL was con- Ambu corporation has released a disposable version of the NPL, the Ambu aScope 4 Rhinolaryngo. As novel tools, they have not yet been extensively studied as compared to reusable NPLs. This is the first known study to assess feedback from otolaryngologists, specifically residents, regarding the quality of the NPL in comparison to reusable NPLs. It is also the first study, to our knowledge, to analyze the associated costs of reusable NPLs at a single academic center. Our study shows that the disposable NPL compares favorably to other reusable NPLs and is preferred over reusable NPLs in terms of convenience and setup, but would benefit from improvement in imaging quality. It also was rated as easier to learn than traditional reusable NPLs; however, 100% of respondents indicated that this is not the first NPL that they have learned to use and this difference can likely be attributed to previously acquired endoscopy skills. Currently the disposable NPL is being used predominantly for consultations within the hospital. Nasopharyngolaryngoscopy is frequently required for these consultations and has been cited as necessary in up to 48% of cases with an additional 16% requiring rhinoscopy in one tertiary center. 10 Given the frequent need for endoscopy, convenience and setup are important factors for maintaining efficiency. Various studies have also commented that the sterilization process is often inadequate and inconsistent. 4 One alternative has been the use of disposable sheaths over the NPL. However, these are still prone to tears and do not fully eliminate the need for reprocessing of the NPL. 12 Given the current COVID-19 pandemic, endoscopy procedures present a high risk for transmission of the SARS-CoV-2 virus. Studies on virucidal efficacy of chemical agents against SARS-CoV-2 are not available. 13 A disposable NPL would negate the need for reprocessing altogether and mitigate concern for any crosscontamination between patients. Limitations of the study include difficulty with distributing the survey to additional institutions. In addition it is unclear whether many of the residents that the survey was distributed to have used the disposable NPL. It was difficult to ascertain which residency programs had actually implemented and utilized the disposable NPL based on the list provided by Ambu. One of the residents responded to the email indicating that they do not use the disposable NPL within the residency program. This residency program includes 25 residents that were included with the 109 residents that received the survey. Residents were instructed to not fill out the survey if they have not used the disposable NPL and this likely falsely lowered the response rate. It was also difficult to estimate the cost of certain materials in our cost analysis of the reusable NPL including cost of detergents, acids, and the machinery required for reprocessing and for that reason it is likely that the per-use cost of the reusable NPL was actually underestimated. Disposable NPLs may offer an alternative option to traditional reusable NPLs and initial feedback from resident physicians is favorable. It was rated superior in regards to setup, convenience, and rated better overall. It was found to be comparable in regards to ergonomics and maneuverability. It was rated inferior regarding imaging quality. Implementation of the disposable NPL for use by otolaryngologists may decrease cross-contamination of disease and given the results of the cost analysis may offer a more cost-effective option than traditional reusable NPLs which have high associated repair costs. Ryan Walczak involved in the study design, data collection, data analysis, manuscript author. Mark Arnold involved in the data analysis, critical revision. Jeewanjot Grewal and Xiao Yuan involved in the data collection. Amar Suryadevara and Haidy Marzouk involved in the study conception and design, data interpretation, and critical revision. The authors declare no conflicts of interest. Routine use of office endoscopy in otolaryngology. Otolaryngology-Head and Neck Surgery Flexible fiberoptic NPL Office-based management of recurrent respiratory papilloma Prevention of disease transmission during flexible laryngoscopy Early assessment of the likely cost effectiveness of single-use flexible video bronchoscopes Cost analysis of single-use (Ambu ® aScope™) and reusable bronchoscopes in the ICU. Ann Intensive Care Analyse de coût comparant les fibroscopes à usage unique (Ambu ® aScope™) et les fibroscopes réutilisables pour l'intubation difficile A cost analysis of reusable and disposable flexible optical scopes for intubation Cost-effectiveness analysis of flexible optical scopes for tracheal intubation: a descriptive comparative study of reusable and single-use scopes Improving the otolaryngology consultation Service in a Teaching Hospital Automated high-level disinfection of nonchanneled flexible endoscopes: duty cycles and endoscope repair Non-inflatable sterile sheath for introduction of the flexible NPL Reusable vs disposable nasopharyngolaryngoscopes: Cost analysis and resident survey