key: cord-0945988-ki0r3p70 authors: Reifart, Joerg; Liebetrau, Christoph; Troidl, Christian; Madlener, Katharina; Rolf, Andreas title: Noninvasive sampling of the distal airspace via HME-filter fluid is not useful to detect SARS-CoV-2 in intubated patients date: 2021-03-30 journal: Crit Care DOI: 10.1186/s13054-021-03549-x sha: a059335a73ea66d108be15080974e60652489fbc doc_id: 945988 cord_uid: ki0r3p70 nan Sampling for SARS-CoV-2 is often carried out via bronchoscopy in intubated patients if upper respiratory samples at nasopharyngeal and oropharyngeal sites are negative or cannot be readily obtained [1] . PCR for detection of SARS-CoV-2 has been reported to have the highest sensitivity in lower respiratory tract samples [2] . Because bronchoscopy is an aerosol-generating procedure, alternative sampling methods with a similar sensitivity are of value. Previously, it has been demonstrated that heat moisture exchanger (HME) filter fluid had a composition approximating that of the fluid in the distal airspace (which is obtained during bronchoalveolar lavage) and can be used to test for pathogens [3] [4] [5] . The present investigation examined whether performing PCR for SARS-CoV-2 on unprocessed HME filter fluid is a viable method to test patients for infection instead of performing bronchoalveolar lavage via bronchoscopy. Patients who had tested positive for SARS-CoV-2 and were treated with invasive ventilation for at least 12 h were enrolled prospectively (Fig. 1 ). The enrollment period was from May 2020 to December 2020. The initial test yielding the positive result was conducted using a nasopharyngeal swab. HME filters were swabbed with a regular swab on the septic side of the filter. The swabs were then placed in virus medium. SARS-CoV-2 PCR test systems used were either the BD MAX ™ System with BioGX SARS-CoV-2 reagents (BD Life Sciences, Sparks, Maryland, USA) or the Hain Lifescience FluoroType ® SARS-CoV-2 plus (Hain Lifescience GmbH, Nehren, Germany). Results of the tests of samples from the HME filters were compared with the results from the nasopharyngeal swab. A sample size of 60 patients appeared to be adequate to compare the two different test methods. This report provides data for the initial 4 patients included in this prospective population. Informed consent was acquired. If the patient was not able to provide informed consent, inclusion occured via an investigator consilium ("Giessener Lösung"). The ethics board of the state of Hessen, Germany, approved the study (AZ 79/20). The data collected from all patients were pseudonymized and entered into a database. The trial was retrospectively registered on November 1st 2020 (DRKS registry; registration: DRKS00023494). Four patients with positive nasopharyngeal swabs were enrolled in the study before an interim analysis of the results showed that it was unlikely that a sensitivity of greater than 90% would be reached. The enrollment was stopped prematurely. Of the 4 HME filter samples assayed, 3 did not test positive for SARS-CoV-2. All patients still tested positive in a bronchoalveolar lavage sample at a later point in time. Further results are provided in Table 1 . Bronchoscopy with bronchoalveolar lavage is commonly used to test for SARS-CoV-2 in intubated patients. This study was designed to determine whether sampling Open Access *Correspondence: j.reifart@kerckhoff-klinik.de 1 Department of Cardiology, Kerckhoff Heart Center, Benekestr. 2-8, 61231 Bad Nauheim, Germany Full list of author information is available at the end of the article HME filter fluid may present a feasible and safer alternative. Our preliminary data showed that HME filter fluid alone, without any additional processing, is not suitable for the detection of SARS-CoV-2 via PCR. Given the manifest disease in the lung as observed in CT scans, a positive SARS-CoV-2 swab in the upper respiratory tract without the lungs being affected is unlikely in patients needing invasive ventilation. Hence, the reason for the negative results remain unclear. Unfortunately, the study did not control for prior inhalation therapy. Some of the fluid could have been nebulized saline instead of precipitated moisture from the distal airspace carrying viral RNA. Even so, viral RNA should still be detectable under these conditions. Further processing of the samples, including the extraction of more liquid via centrifugation of the HME filters, might yield better results, though processing steps would render the technique less applicable and appealing for widespread use [5] . American Association for Bronchology and Interventional Pulmonology (AABIP) statement on the use of bronchoscopy and respiratory specimen collection in patients with suspected or confirmed COVID-19 infection Detection of SARS-CoV-2 in different types of clinical specimens Novel method for noninvasive sampling of the distal airspace in acute respiratory distress syndrome A pilot study of the noninvasive assessment of the lung microbiota as a potential tool for the early diagnosis of ventilator-associated pneumonia Non-invasive detection of pulmonary pathogens in ventilator-circuit filters by PCR Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations We thank Elizabeth Martinson, PhD, from the KHFI Editorial Office for her editorial assistance. All authors were involved in the conception of the work, the interpretation of data as well as the drafting and revising the manuscript. All authors read and approved the final manuscript. The study was funded by the local research institute (Kerckhoff Herzforschungsinstitut (KHFI)). Data can be made available upon request. The study was approved by the local ethics committee. All patients participated with consent. Does not apply since no identifying information is presented. There are no financial or nonfinancial disclosures that could be construed as a conflict of interest in regard to this manuscript.