key: cord-0943534-y3nj5pjh authors: Grossegesse, Marica; Nitsche, Andreas; Schaade, Lars; Doellinger, Joerg title: Application of spectral library prediction for parallel reaction monitoring of viral peptides date: 2021-02-22 journal: Proteomics DOI: 10.1002/pmic.202000226 sha: 927e19452307e24dcb7f089317a03192a4915b88 doc_id: 943534 cord_uid: y3nj5pjh A major part of the analysis of parallel reaction monitoring (PRM) data is the comparison of observed fragment ion intensities to a library spectrum. Classically, these libraries are generated by data‐dependent acquisition (DDA). Here we test Prosit, a published deep neural network algorithm, for its applicability in predicting spectral libraries for PRM. For this purpose, we targeted 1,529 precursors derived from synthetic viral peptides and analyzed the data with Prosit and DDA‐derived libraries. Viral peptides were chosen as an example, because virology is an area where in silico library generation could significantly improve PRM assay design. With both libraries a total of 1,174 precursors were identified. Notably, compared to the DDA‐derived library, we could identify 101 more precursors by using the Prosit‐derived library. Additionally, we show that Prosit can be applied to predict tandem mass spectra of synthetic viral peptides with different collision energies. Finally, we used a spectral library predicted by Prosit and a DDA library to identify SARS‐CoV‐2 peptides from a simulated oropharyngeal swab demonstrating that both libraries are suited for peptide identification by PRM. Summarized, Prosit‐derived viral spectral libraries predicted in silico can be used for PRM data analysis, making DDA analysis for library generation partially redundant in the future. This article is protected by copyright. All rights reserved This article is protected by copyright. All rights reserved. Parallel reaction monitoring (PRM) is a mass spectrometry method which is applied for sensitive and selective target analysis. In PRM mode, the target peptide is filtered by the quadrupole, fragmented, e.g. with higher-energy collisional dissociation (HCD), and the fragment ions are detected in a highresolution mass analyzer, such as an orbitrap. PRM data is most often analyzed in the Skyline software environment, which has been developed for targeted mass spectrometry data analysis. [1] For correct peptide identification, a combination of multiple parameters is used. While heavy labeled peptides co-eluting with the peptide of interest are the gold standard, retention time, precursor mass, and matching of fragment ions to a spectral library are commonly applied in order to identify unambiguously the peptide of interest. The similarity of the measured fragment spectrum to a library spectrum is calculated by normalized spectral contrast angle and called dotp value in Skyline. Until now, spectra for spectral libraries had to be generated in separate analysis prior to the actual PRM run, using data-dependent analysis (DDA). However, recently the in silico generation of spectral libraries has been introduced by different tandem mass spectra prediction algorithms. [2] [3] [4] [5] [6] [7] In silico prediction of spectral libraries can be an important tool for targeted MS such as PRM, especially when library generation by DDA is not straightforward. Another advantage of in silico-generated libraries is that they do not have an inherent detection bias like DDA which can lead to the missing of target peptides. As a result of the SARS-CoV-2 pandemic, the analysis of viruses by MS is becoming increasingly popular. [8] [9] [10] In virology, tandem mass spectra prediction could be a valuable tool, since generation of viral spectral libraries is still challenging. This is due to the safety measures needed when working with certain viruses, the low abundance of viruses in the host background matrix or simply the unavailability of certain viruses. In this study, we chose to compare spectral libraries generated by DDA and predicted in silico by Prosit for their applicability to virus-targeted PRM. Prosit is a freely available (https://www.proteomicsdb.org/prosit/) tandem mass spectra prediction algorithm to generate spectral libraries compatible with Skyline. [2] The Prosit neural network algorithm has been trained on publicly available datasets from Proteome Tools [11] consisting of human peptide data. It has been shown that Prosit can be used for metaproteomic data analysis, suggesting its applicability to viral peptide spectra prediction. Moreover, Prosit has been shown to outperform other tools in predicting spectra for designated mass spectrometers like the Orbitrap Fusion and Lumos. [12] Technical brief This article is protected by copyright. All rights reserved. However, so far it has remained elusive how Prosit performs in virus-targeted PRM data analysis in comparison to classical DDA libraries, which is the main focus of this study. For the first two experiments we used synthetic peptides of diverse highly pathogenic viruses, namely Ebola virus, Marburg virus, Lassa virus, SARS coronavirus, Variola virus, Crimean-Congo hemorrhagic fever virus, Machupo virus, and Eastern, Western and Venezuelan equine encephalitis virus. All of these viruses have to be handled in high-containment laboratories with biosafety level 3 or 4. Without prior knowledge of the peptides' detectability by nLC-MS/MS, we ordered a total of 1,569 crude synthetic viral peptides in six pools from JPT (Berlin, Germany). All peptides are specific for the respective virus. The peptide pools were each analyzed in triplicate by DDA on an Orbitrap Q Exactive Plus, using a top10 method. Raw files were searched with MaxQuant [13] against the respective virus database (UniProt) with a peptide FDR of 1%. Detailed MS analysis and MaxQuant parameters can be found in the supporting information and the data uploaded to ProteomeXchange Consortium. MaxQuant .msms output files were used to generate spectral libraries with BiblioSpec implemented in the Skyline environment. BiblioSpec uses the best-scored peptides for library generation. In the case of multiple spectra with identical scores, the one with the highest total ion current is selected. The respective DDA spectral libraries derived from the six peptide pools contained 1,529 precursors belonging to 1,026 peptides. In the following, we will refer to the DDA libraries as a single library although a library for each peptide pool was used. In the next step, these precursors were analyzed by PRM to ensure that every targeted peptide could theoretically be detected with the DDA spectral library. For this purpose, the 1,529 precursors were divided into 38 unscheduled PRM runs with 40 precursors per run and a single run containing the remaining nine peptides. For PRM runs, the six synthetic peptide pools were used in the same way as for DDA runs. Peptide Figure 1C) . Notably, the peptides with a length of six amino acids showed the lowest correlation to the Prosit spectral library (Figure 1D ). This observation is conclusive, because Prosit has been trained on peptides with a length of seven to 30 amino acids. This demonstrates that under the given experimental conditions Prosit performs very well for the prediction of tandem mass spectra between seven to 21 amino acids in length, but is less suited for peptides of six amino acids. This observation is underlined by 77 peptides that were exclusively identified with the DDA library (Figure 1A and E). For the most part the peptides that could not be identified with Prosit had a length of six amino acids. Since short peptides are not very selective, they are generally not suited as PRM targets. As shown further in figure 1A , 178 precursors could be exclusively identified with the Prosit library. Moreover notably, by using the Prosit library overall more fragment ions were identified, especially more doubly charged ones ( Figure 1F) . Technical brief This article is protected by copyright. All rights reserved. Demonstrating that Prosit can be used to predict synthetic viral peptides with a fixed NCE of 25, we next aimed to test its prediction capabilities for viral peptides analyzed with different collision energies. Different collision energies are particularly interesting for PRM, because they can be optimized for each precursor separately to ensure optimal fragmentation for identification. For this purpose, we selected 121 peptides with DDA library dotp value of ≥ 0.99 and at least four identified fragment ions. These 121 peptides were analyzed using PRM with five different NCEs (19, 22, 25, 28, Technical brief This article is protected by copyright. All rights reserved. and 31). Prosit spectral libraries adjusted for the respective NCEs were generated (Prosit_2020_intensity_model) and library matches were analyzed in Skyline. This resulted in a median dotp value between 0.93 and 0.95, depending on the NCE (Figure 2A ). An example of the viral peptide spectra predicted at different NCEs is shown in Figure 2B . For the doubly charged peptide LTGSPCAAFIGDDNIVK at an NCE of 19, the doubly charged y13-ion has the highest intensity, while at an NCE of 25 or higher, the single charged y7-ion has the highest intensity in the spectrum. This data suggests that Prosit can be used for NCE optimization during PRM assay design. However, it has to be noted that Prosit calculates relative fragment intensities which do not allow a comparison of the sensitivity of different NCEs for target detection. This has to be considered when optimizing NCEs. This article is protected by copyright. All rights reserved. After showing that Prosit works well for synthetic viral peptides, we aimed to test it in a potential diagnostic PRM application example. Currently, as a result of the SARS-CoV-2 pandemic, MS-based proteomics is discussed as an alternative method for virus diagnostics. In particular PRM has been suggested as the method of choice to detect SARS-CoV-2 proteins from patient samples like nasoand oropharyngeal swabs [10, [14] [15] [16] . To simulate a positive patient sample, we spiked cell-culture derived SARS-CoV-2 in a negative oropharyngeal swab to a final cT value of about 16. As it has been shown that the nucleoprotein (N protein) is the most abundant SARS-CoV-2 protein we used it as a target for detection by PRM [15] . Potential viral target peptides were identified by DDA of SARS- Summarized, the identification of more than 1,000 precursors derived from synthetic viral peptides and, moreover, 21 precursors derived from SARS-CoV-2 in an oropharyngeal swab demonstrates that Prosit can predict viral tandem mass spectra for PRM with at least equal performance compared to DDA-derived spectral libraries. When using Prosit, we could identify more fragment ions and, most notably, more doubly charged fragment ions compared to using DDA-derived libraries. Furthermore, we show that viral tandem mass spectra with different collision energies can be reliably predicted with Prosit. This study is the first large-scale application of Prosit -a spectral library prediction tool trained on human peptide data -for the generation of high-quality spectra of viral peptides for PRM data analysis. Nevertheless, from our data we conclude that Prosit can be routinely used to generate spectral libraries for viral PRM data analysis. In the future Prosit could facilitate PRM assay design, e.g. in virus-targeted proteomics. Features like precursor intensity and charge state prediction would further facilitate assay design. Technical brief This article is protected by copyright. All rights reserved. Skyline: an open source document editor for creating and analyzing targeted proteomics experiments Prosit: proteome-wide prediction of peptide tandem mass spectra by deep learning MS2PIP prediction server: compute and visualize MS2 peak intensity predictions for CID and HCD fragmentation High-quality MS/MS spectrum prediction for data-dependent and dataindependent acquisition data analysis pDeep: Predicting MS/MS Spectra of Peptides with Deep Learning Prediction of LC-MS/MS Properties of Peptides from Sequence by Deep Learning MS/MS Spectrum Prediction for Modified Peptides Using pDeep2 Trained by Transfer Learning Targeted Proteomics for the Detection of SARS-CoV-2 Proteins Mass Spectrometric Identification of SARS-CoV-2 Proteins from Gargle Solution Samples of COVID-19 Patients Data, reagents, assays and merits of proteomics for SARS-CoV-2 research and testing Building ProteomeTools based on a complete synthetic human proteome A Comprehensive Evaluation of MS/MS Spectrum Prediction Tools for Shotgun Proteomics MaxQuant enables high peptide identification rates, individualized p.p.b.-range mass accuracies and proteome-wide protein quantification Mass-Spectrometric Detection of SARS-CoV-2 Virus in Scrapings of the Epithelium of the Nasopharynx of Infected Patients via Nucleocapsid N Protein Establishing a mass spectrometry-based system for rapid detection of SARS-CoV-2 in large clinical sample cohorts Perspective on Proteomics for Virus Detection in Clinical Samples Supporting information The supporting information contains detailed sample preparation and LC-MS/MS analysis parameters The authors thank Ursula Erikli for copy-editing. The authors declare no conflict of interest. The mass spectrometry proteomics data have been deposited to Zenodo