key: cord-0942582-4q7nyh8a authors: Lee, Cherl-Joon; Shin, Wonseok; Mun, Seyoung; Yu, Minjae; Choi, Young-Bong; Kim, Dong Hee; Han, Kyudong title: Diagnostic evaluation of qRT-PCR-based kit and dPCR-based kit for COVID-19 date: 2021-09-15 journal: Genes Genomics DOI: 10.1007/s13258-021-01162-4 sha: e16ad279c770f3138c3de6903d81c0adb4e4b22f doc_id: 942582 cord_uid: 4q7nyh8a BACKGROUND: Coronavirus disease of 2019 (COVID-19) is well known as a fatal disease, first discovered at Wuhan in China, ranging from mild to death, such as shortness of breath and fever. Early diagnosis of COVID-19 is a crucial point in preventing global prevalence. OBJECTIVE: We aimed to evaluate the diagnostic competency and efficiency with the Allplex™ 2019-nCoV Assay kit and the Dr. PCR 20 K COVID-19 Detection kit, designed based on the qRT-PCR and dPCR technologies, respectively. METHODS: A total of 30 negative and 20 COVID-19 positive specimens were assigned to the diagnostic test by using different COVID-19 diagnosis kits. Diagnostic accuracy was measured by statistical testing with sensitivity, specificity, and co-efficiency calculations. RESULTS: Comparing both diagnostic kits, we confirmed that the diagnostic results of 30 negative and 20 positive cases were the same pre-diagnostic results. The diagnostic statistics test results were perfectly matched with value (1). Cohen’s Kappa coefficient was demonstrated that the given kits in two different ways were “almost perfect” with value (1). In evaluating the detection capability, the dilutional linearity experiments substantiate that the Dr. PCR 20 K COVID-19 Detection kit could detect SARS-CoV-2 viral load at a concentration ten times lower than that of the Allplex™ 2019-nCoV Assay kit. CONCLUSIONS: In this study, we propose that the dPCR diagnosis using LOAA dPCR could be a powerful method for COVID-19 point-of-care tests requiring immediate diagnosis in a limited time and space through the advantages of relatively low sample concentration and small equipment size compared to conventional qRT-PCR. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13258-021-01162-4. Coronavirus disease of 2019 (COVID-19) is a human respiratory infectious disease caused by a novel type of coronavirus (Severe acute respiratory syndrome coronavirus 2; SARS-CoV-2) that was first reported in Wuhan, China, in December 2019 and has become a worldwide pandemic Zhang et al. 2020) . As far as is known, SARS-CoV-2 spreads from an infected person to others through respiratory fluids and aerosols carrying the infectious virus. The rapid spread of the COVID-19 pandemic worldwide has been caused by misdiagnosis and asymptomatic transmission (Syal 2021) . COVID-19 can cause mild symptoms ranging from loss of smell and taste, fever, muscle pain, and acute shortness of breath (Cascella et al. 2021; Garg et al. 2020) . However, since senior citizens, immunocompromised patients, and patients with underlying diseases cause death in severe cases, accurate early diagnosis and comprehensive infectious disease prevention and control are required worldwide before developing of a COVID-19 therapeutic agent. Early diagnosis of COVID-19 is important because it helps determine the direction of treatment and can prevent several fatal complications at an early stage (Peck 2020) . There are several methods for COVID-19 diagnostics and detection, including cell culture and microscopy, radiology-based detection, nucleic acid amplification tests, quantitative real-time PCR (qRT-PCR), and immunoassaybased detection (Russo et al. 2020; Udugama et al. 2020 ). Among the methods mentioned above, the qRT-PCR and the immunoassay-based detection methods are predominantly used for COVID-19 diagnosis. First, the immunoassay-based detection method uses the point that when the SARS-CoV-2 enters the human body, it stimulates the adaptive immune system to generate antibodies. This method uses IgM, which is produced 7 days and peaks at 28 days after SARS-CoV-2 viral infection, and IgG, which is generated 10 days and peaks at 49 days after SARS-CoV-2 viral infection (Padoan et al. 2020; Xu et al. 2020) . The advantage of this method is that the result can be checked after approximately 10 min, it is not expensive, and it can be checked quickly and easily confirmed with a single drop of blood. However, the limitations of the immunoassay-based detection method are: First, in the primary antibody test, it may be challenging to determine whether a SARS-CoV-2-positive individual is infected due to the lack of antibodies in the body. Second, even in SARS-CoV-2-positive individuals, there are cases in which no antibody response or antibody levels cannot be maintained. Third, the low accuracy of this test (50-70%) has been reported (Dhamad and Rhida 2020; Watson et al. 2020 ). On the other hand, the qRT-PCR is a method that can confirm in real time using specific primers and probes for a specific viral gene sequence capable of diagnosing COVID-19. Currently, qRT-PCR is used as a gold standard in the COVID-19 diagnosis (Goudouris 2021; Huergo and Thanh 2021; Murphy and Bustin 2009 ). The reason is that SARS-CoV-2 detection shows very high sensitivity (98.2%) and specificity (100%), and quantitative analysis is straightforward . However, the qRT-PCR method can only be used under laboratory condition because it requires the medium-sized equipment and various laboratory tools for pre-sample preparation operation (Gupta et al. 2021) . Recently, in the diagnosis of COVID-19, a dPCR analysis method that compensates for the weakness of qRT-PCR is emerging and difficulty in field diagnosis (Dong et al. 2021; Verhaegen et al. 2016) . The dPCR method for diagnosing COVID-19 is similar to qRT-PCR by hybridizing specific primers and probes to specific viral gene sequences (Dang et al. 2020 ). Among the currently commercialized dPCR systems, Optolane's LOAA digital real-time PCR analyzer (LOAA dPCR, Optolane, Seongnam, Republic of Korea) released in 2020 integrates light source control and thermal control sensors to miniaturize the equipment, so that it takes less space than the qRT-PCR system. In addition, LOAA dPCR can monitor real-time amplification, and the target gene is placed in each well. Amplification and fluorescence analysis are performed simultaneously in each well, so the probability of false negatives by the experiment is low. Therefore, LOAA dPCR with a small size and high accuracy is expected to play a role as a point of care testing (POCT) device in the future. Currently, reagent products approved for emergency use for COVID-19 diagnosis in Korea have been developed by Kogen Biotech, Seegene, Solgent, SD Biosensor, Biosewoom, and etc. (Garg et al. 2021; Park and Chung 2021; Sung et al. 2020 ). Among them, Allplex™ 2019-nCoV Assay kit (Seegene, Seoul, Republic of Korea) is a qRT-PCR-based COVID-19 diagnostic kit and has received the US Food and Drug Administration (FDA) Emergency Use Authorization (EUA) and the Korean Ministry of Food and Drug Safety (KMFDS) EUA approval (Lai et al. 2021 ). In the previous study, the Allplex™ 2019-nCoV Assay kit (Seegene, Seoul, Republic of Korea) showed high performance in sensitivity as a result of confirming clinical performance by applying KCDC qRT-PCR protocol as a gold standard (Freire-Paspuel and Garcia-Bereguiain 2021). Therefore, currently in Korea, the Allplex™ 2019-nCoV Assay kit (Seegene, Seoul, Republic of Korea) is typically used for the COVID-19 diagnosis. However, since this assay is a qRT-PCR-based method, it has disadvantages such as space limitation, relatively high qPCR equipment cost, and relatively long experimental time. In order to overcome these shortcomings, Optolane Co., Ltd. launched the LOAA dPCR assay (Optolane, Seongnam, Republic of Korea) in 2020, a compact and relatively short test time. In particular, the semiconductor chip-based Dr. PCR 20 K COVID-19 detection kit (Optolane, Seongnam, Republic of Korea) is the first dPCR-based COVID-19 diagnostic kit developed in Korea. In addition, this kit was approved for COVID-19 diagnostic reagent from the Korea Ministry of Food and Drug Safety (MFDS) on May 18, 2020. Here, we performed qRT-PCR with the Allplex™ Assay kit currently used as a gold standard and dPCR with the Dr. PCR 20 K COVID-19 Detection kit using actual COVID-19 patient samples, respectively. In addition, based on the results derived from each method, the effectiveness of COVDI-19 diagnosis was evaluated and comparatively analyzed. The Korean government has sufficiently secured and supported various types of COVID-19 samples, including respiratory and blood, from a total of six medical institutions with proven clinical evaluation capabilities. Here, we obtained a total of 50 specimens, of which were derived from 38 pharyngeal swabs (upper respiratory samples) and 12 sputa (lower respiratory samples) from Seoul Clinical Laboratories (SCL, Yongin, Republic of Korea) among those institutions. The specimens obtained are the residual samples from 20 positive and 30 negative specimens diagnosed with COVID-19 at the SCL medical institution. All specimens were stored in 3 mL of viral transport media (Cat. No UTNFS-3B-1, Noble Biosciences, Inc., Hwaseong, Republic of Korea). This study was performed in accordance with the Declaration of Helsinki and the International Conference on Harmonization Good Clinical Practice guidelines and approved by relevant regulatory from SCL Institutional Review Board (IRB-20-008). All specimen donors submitted written consent before they participated in the study. In a total of 50 specimens, viral RNAs were isolated from 38 pharyngeal swabs using each 200 µL of a viral transport media with the KingFisher Flex system (ThermoFisher Scientific Inc., Worcester, MA, USA), an automated nucleic acid extraction system, following the manufacturer's guidelines protocol (Lin et al. 2021 ). In addition, we isolated viral RNAs using the Advansure™ E3 system (LG Chem, Ltd., Seoul, Korea), an automated nucleic acid extraction system, and 200 µL each of 12 viral transport media obtained from sputum specimens according to the manufacturer's guideline . The viral RNAs isolated by each system were dissolved in 50 µL of RNasefree water. Then, the eluted samples were stored at − 80 ℃ in a deep freezer. We carried out qRT-PCR using the stored RNA samples from the 50 specimens to evaluate the COVID-19 detection capability of Allplex™ 2019-nCoV Assay kit (Cat. No RP10250X, Seegene, Seoul, Republic of Korea). The qRT-PCR assay was performed according to the protocol of the manufacturer (Fig. 1) . The Allplex™ 2019-nCoV Assay kit includes primer sets and probes targeting the RdRp, E and N genes of SARS-CoV-2 (Ambrosi et al. 2021) . The target viral genes amplification was performed by following process: cDNA synthesis step of 20 min at 50 ℃, predenaturation step of 15 min at 95℃, followed by 45 cycles of denaturation step 15 s at 94 ℃, 30 s at 58 ℃ for annealing and extension steps. CFX96™ Real-Time PCR Detection System (Bio-Rad, Hercules, CA, USA) was used for qRT-PCR assay. dPCR systems is divided into droplet type and separation type according to the method of dispensing the samples ( Fig. 2) (Cao et al. 2017 ). Among them, the LOAA dPCR system (Optolane, Seongnam, Republic of Korea) released in 2020 is a separation type dPCR equipment. To evaluate the COVID-19 detection capability of Dr. PCR 20 K COVID-19 Detection kit (Cat no. DCM402-X, Optolane, Seongnam, Republic of Korea), we performed LOAA dPCR assay using the same 50 viral RNAs that we carried out qRT-PCR analysis on. The dPCR assay with Dr. PCR 20 K COVID-19 Detection kit was performed following to the manufacture's protocol ( Fig. 1 ). Dr. PCR 20 K COVID-19 Detection kit includes primer sets and probes that is targeting the RdRp and E genes of SARS-CoV-2. The target viral genes amplification was conducted by following process: cDNA synthesis step of 10 min at 50 ℃, pre-denaturation step of 10 min at 95 ℃, followed by 45 cycles of denaturation step 10 s at 95 ℃, 60 s at 60 ℃ for annealing & extension step. The qRT-PCR-based Allplex™ 2019-nCoV Assay kit results were measured as Ct values and dPCR-based Dr. PCR 20 K COVID-19 Detection kit results were measured as C/µL values. The Ct values of the Allplex™ 2019-nCoV Assay kit results were automatically determined for a diagnosis of COVID-19 using the Seegene Viewer (Freppel et al. 2020 ). The C/µL values of Dr. PCR 20 K COVID-19 detection kit results were automatically determined by LOAA Dr. PCR software 3.0.0 as a diagnosis of COVID-19. We calculated the COVID-19 diagnosis agreement of both kits using Cohen's Kappa analysis (Daly et al. 2019; Inaba et al. 2021) . Kappa (K) value is interpreted as poor (K < 0.00), slight (0.00 < K < 0.20), fair (0.20 < K < 0.40), moderate (0.41 < K < 0.60), substantial (0.61 < K < 0.80), and almost perfect (0.81 < K < 1.00). In addition, we performed the dilutional linearity experiments by spike-in the high concentration of COVID-19 positive sample (Ct value near 10) to the negative sample to compare the detection capability according to the dilution factor (10 −1 to 10 −10 ) of two kits ). We selected the most popular qRT-PCR-based Allplex™ 2019-nCoV Assay kit in Korea to evaluate the efficiency of COVID-19 diagnosis. In addition, pharyngeal swab or sputum samples from 20 COVID-19 positive patients and 30 normal individuals (i.e., COVID-19 negative) were obtained from Seoul Clinical Laboratories (Gyeonggi, Republic of Korea) (Supplementary Table S1 ). The COVID-19 diagnosis result using the Allplex™ 2019-nCoV Assay kit is evaluated by the Ct value of qRT-PCR. As shown in Table 1 , the potential outcome types of this kit are reported for a total of 9 CASE types (CASE-1 to -9) (Seegene 2021) . When the Ct value of each internal control (IC), E gene, RdRp gene, or N gene is ≤ 40, it is indicated as "Detected" (+), and when it is > 40 or not applicable (N/A), it is indicated as "Not detected" (−). Depending on the (+) or (−) result of each gene, CASE-1 to -6 are determined to be "2019-nCoV positive" (Table 1 ). In the case of CASE-7, if IC is (+/−), E gene is (+), and RdRp gene and N gene are (−) determined as "Presumptive positive for 2019-nCoV", and re-experiment is required. If the IC is (+) and all viral genes are (−) in the sample, it is determined as "Negative" (CASE-8). Samples with all (−) results for IC (HEX) and all viral genes are determined as "Invalid" (CASE-9) (Supplementary information). As a result of performing a COVID-19 diagnostic test using the qRT-PCR-based Allplex™ 2019-nCoV Assay kit with a total of 50 individual specimens, all ODP1 to ODP30 specimens extracted from normal individuals not infected with COVID-19 were "negative". In addition, all ODP31 to ODP50 specimens extracted from patients diagnosed with COVID-19 obtained "2019-nCoV positive" results (Table 2) . Therefore, in the diagnostic evaluation of COVID-19 using the Allplex™ 2019-nCoV Assay kit, the false-negative and false-positive rates were 0. In addition, the diagnostic sensitivity and specificity were 1 (van Stralen et al. 2009 ). Although we obtained results with a relatively small number of specimens, we confirmed that the qRT-PCR assay showed very high sensitivity and specificity using the Allplex™ 2019-nCoV Assay kit (Supplementary Table S2 ). We performed a COVID-19 diagnostic test using the LOAA dPCR (Optolane, Seongnam, Republic of Korea) equipment and the Dr. PCR 20 K COVD-19 Detection kit (Optolane, Seongnam, Republic of Korea) with the same samples evaluated above. As shown in Table 3 , LOAA dPCR assay results are reported as CASE-1 to -5. To determine the diagnostic test efficacy, dPCR assay was performed using non-template control (NTC), positive control (PC), and PCR control (PCRC), respectively. The PC is composed of when RdRp gene and E gene. A valid decision can only be made when the number of valid wells is greater than 10,000. The experiment is valid when RdRp gene (FAM dye) has a value of ≥ 0.257 C/µL, E gene (FAM dye) ≥ 0.24 C/µL, and PCRC has a value of ≥ 1 C/µL (Table 3) . As a result of the dPCR assay using the Dr. PCR 20 K COVD-19 Detection kit, 30 out of a total of 50 specimens obtained SARS-CoV-2 negative results, and 20 specimens obtained SARS-CoV-2 positive results (Table 4 ). Similar to the Allplex™ 2019-nCoV Assay kit, the ODP1 to ODP30 specimens were extracted from normal individuals not infected with COVID-19, and all of the SARS-CoV-2 negative results were obtained. In addition, the ODP31 to ODP50 specimens were samples extracted from patients diagnosed with COVID-19, and all of them obtained SARS-CoV-2 positive results. Therefore, in the diagnostic evaluation of COVID-19 using the dPCR assay with Dr. PCR 20 K COVD-19 Detection kit, the false-negative and false-positive rates were 0. In addition, the diagnostic sensitivity and specificity were 1 (Supplementary Table S2 ). Comparison of diagnostic results between qRT-PCR-based Allplex™ 2019-nCoV Assay kit and dPCR-based Dr. PCR 20 K COVD-19 Detection kit showed the same results (Supplementary Table S3 ). Cohen's Kappa coefficient was tested to measure the reliability and agreement between the two results (Czodrowski 2014) . The Kappa Coefficient has a value between 0 and 1, and the closer to 1, the more consistent the data to be compared. Therefore, when the detection results of the Allplex™ 2019-nCoV Assay kit and the Dr. PCR 20 K COVID-19 Detection kit were confirmed with Cohen's Kappa Coefficient, the value was "Almost Perfect" with "1". In order to evaluate the detection capability between the two kits according to the extraction efficiency of viral RNA, a high concentration of COVID-19 positive sample (Ct value near 10) was prepared. The high concentration of COVID-19 positive sample was spike-in treated with the negative patient sample, diluted, and then the dilutional linearity experiments were performed. The correlation between the detection capability between the two kits was confirmed with the spike-in treatment of the negative patient sample on the high concentration of COVID-19 positive sample. The treated sample was diluted from 10 −1 to 10 −10 (Supplementary Table S4 ), and then the dilutional linearity experiments were performed. As shown in Table 5 , the Allplex™ 2019-nCoV Assay kit result can confirm that COVID-19 was detected up to 10 −6 . On the other hand, the results of the Dr. PCR 20 K COVID-19 Detection kit were capable of detecting COVID-19 up to 10 −7 (Table 6 ). This indicates that the Dr. PCR 20 K COVID-19 detection kit was about 10 times higher than the Allplex™ 2019-nCoV Assay kit in the detection capability according to the extraction efficiency of viral RNA. In addition, the regression analysis results of each kit according to the dilution factor showed that the Allplex™ 2019-nCoV Assay kit had an average of R 2 = 0.9972, and the Dr. PCR 20 K COVID-19 Detection kit was R 2 = 0.9948, confirming very high detection reliability for both kits (Fig. 3) . In summary, we represent that the diagnosis of COVID-19 using dPCR is advantageous compared to qRT-PCR in samples infected with infinitesimal amounts of SARS-CoV-2 in the early stages of infection. We performed correlation analysis on the detection levels of RdRp gene and E gene from diluted viral RNA extracted from qRT-PCR-based Allplex™ 2019-nCoV Assay kit and dPCR-based Dr. PCR 20 K COVID-19 Detection kit. As shown in Fig. 4 , R 2 was confirmed through regression analysis in which qRT-PCR was the Ct value and dPCR was the C/µL value for each dilution factor extract. As a result, the R 2 value was 0.994 in the RdRp gene and 0.9964 in the E gene, which means that the two experiments have a very high correlation for each gene. In this study, Optolane's Dr. PCR 20 K COVID-19 Detection kit was compared with Seegene's Allplex™ 2019-nCoV Assay kit, a product that has already received the US FDA EUA and the Korea MFDS EUA approval for clinical efficacy evaluation. As a result of testing the same COVID-19 diagnostic positive and negative samples, it was confirmed that the results of the dPCR-based Dr. PCR 20 K COVID-19 Detection kit and the results of qRT-PCR-based Allplex™ 2019-nCoV Assay kit were consistent. That is, it was confirmed that these two kits had high sensitivity and specificity in the evaluation of the capability to detect COVID-19 using SARS-CoV-2 viral nucleic acids extracted from sputum and nasopharyngeal smears. However, according to the dilutional linearity experiments results, the Dr. PCR 20 K COVID-19 Detection kit confirmed about ten times higher detection capability at a lower viral load than the Allplex™ 2019-nCoV Assay kit. Taken together, we confirmed that the detection of COVID-19 using LOAA dPCR is advantageous compared to qRT-PCR in terms of relatively lower sample concentration, the small size of equipment, and low equipment price. Therefore, we propose that the use of LOAA dPCR can be expected for COVID-19 point-of-care testing (POCT) in confined spaces and where the immediate diagnosis is required. The online version contains supplementary material available at https:// doi. org/ 10. 1007/ s13258-021-01162-4. SARS-CoV-2: comparative analysis of different RNA extraction methods Advances in digital polymerase chain reaction (dPCR) and its emerging biomedical applications Di Napoli R (2021) Features, evaluation, and treatment of Coronavirus Validation of real-time RT-PCR for detection of SARS-CoV-2 in the early stages of the COVID-19 outbreak in the Republic of Count on kappa Empirical evaluation of SUCRA-based treatment ranks in network meta-analysis: quantifying robustness using Cohen's kappa Comparison of qualitative and quantitative analyses of COVID-19 clinical samples COVID-19: molecular and serological detection methods Highly accurate and sensitive diagnostic detection of SARS-CoV-2 by digital PCR AccuPower SARS-CoV-2 Multiplex RT-PCR kit (Bioneer, South Korea)" and "Allplex 2019-nCoV Assay (Seegene, South Korea)" for SARS-CoV-2 RT-PCR diagnosis: Korean CDC EUA as a quality control proxy for developing countries Efficient SARS-CoV-2 detection in unextracted oro-nasopharyngeal specimens by rRT-PCR with the Seegene Allplex (TM) 2019-nCoV assay Beyond fever, cough and dyspnea: the neurology of COVID-19 Evaluation of seven commercial RT-PCR kits for COVID-19 testing in pooled clinical specimens Laboratory diagnosis of COVID-19 Point-of-care PCR assays for COVID-19 detection Current advances in the detection of COVID-19 and evaluation of the humoral response Diagnostic accuracy of LAMP versus PCR over the course of SARS-CoV-2 infection Analytical and clinical performance of droplet digital PCR in the detection and quantification of SARS-CoV-2 Wuhan to World: the COVID-19 pandemic In vitro diagnostics of coronavirus disease 2019: technologies and application Fluorescence polarization system for rapid COVID-19 diagnosis Experience with false-positive test results on the TaqPath realtime reverse transcription-polymerase chain reaction Coronavirus Disease 2019 (COVID-19) testing platform Reliability of real-time reverse-transcription PCR in clinical diagnostics: gold standard or substandard? Analytical performances of a chemiluminescence immunoassay for SARS-CoV-2 IgM/IgG and antibody kinetics Learning from past pandemic governance: early response and public-private partnerships in testing of COVID-19 in South Korea Early diagnosis and rapid isolation: response to COVID-19 outbreak in Korea Grp VC-(2020) Current status of laboratory diagnosis for COVID-19: a narrative review AllplexTM 2019-nCoV Assay v 2.2 (Cat no RP10250X/ RP10252W) instructions for use COVID-19 molecular testing in Korea: practical essentials and answers from experts based on experiences of emergency use authorization assays Guidelines on newly identified limitations of diagnostic tools for COVID-19 and consequences Diagnosing COVID-19: the disease and tools for detection Diagnostic methods I: sensitivity, specificity, and other measures of accuracy Comparison of droplet digital PCR and qPCR for the quantification of Shiga toxin-producing Escherichia coli in Bovine Feces Interpreting a covid-19 test result COVID-19 diagnostic testing: technology perspective Clinical characteristics of COVID-19-infected cancer patients: a retrospective case study in three hospitals within Wuhan The authors gratefully acknowledge Center for Bio-Medical Engineering Core Facility at Dankook University for providing critical reagents and equipment. This study has been done with the participation of undergraduate students working at DKU-Theragen institute for NGS analysis (DTiNa) of Dankook University. The research institute has been supported by the VIP system as a part of the University innovation Support Program 2021 of Dankook University. Conflict of interest Cherl-Joon Lee, Wonseok Shin, Seyoung Mun, Minjae Yu, Young-Bong Choi, Dong Hee Kim, and Kyudong Han declare that we have no conflict of interest.Ethical approval All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee.