key: cord-0940600-fvnohc40 authors: Greig, P. R.; Carvalho, C.; El‐Boghdadly, K.; Ramessur, S. title: Safety testing improvised COVID‐19 personal protective equipment based on a modified full‐face snorkel mask date: 2020-04-19 journal: Anaesthesia DOI: 10.1111/anae.15085 sha: 278c0dedb566c78d7c940de3b0a8c4e87e34bedb doc_id: 940600 cord_uid: fvnohc40 Reported shortages of personal protective equipment (PPE) in the NHS have caused anxiety amongst healthcare workers [1]. Several designs for improvised PPE have been circulated online and via social media. One particularly widely shared design involves a 3D printed adaptor to allow the mating of a standard anaesthetic heat and moisture exchange (HME) filter to a commercially available snorkelling mask. Thingiverse, an online repository of 3D printable files, contains at least 18 adaptor designs that users can download [2]. Reported shortages of personal protective equipment (PPE) in the NHS have caused anxiety among healthcare workers [1] . Several designs for improvised PPE have been circulated online and via social media. One particularly widely shared design involves a 3D printed adaptor to allow the mating of a standard anaesthetic heat and moisture exchange (HME) filter to a commercially available snorkelling mask. Thingiverse, an online repository of 3D printable files, contains at least 18 adaptor designs that users can download [2] . Although one specific combination of mask, filter and HME has apparently passed fit-testing [3] , given the variation in masks, adaptors and HME filters we are concerned there are insufficient safety data to recommend general use of these devices. Websites generally contain important disclaimers that the systems have not been subjected to peer review or rigorously tested, but we remain anxious that users may attempt to wear these devices in clinical practice without proper validation. To evaluate one such design, we tested PPE based on an Omew full-face snorkel mask purchased from Amazon [4] . An adaptor from the Thingiverse website was printed on a 3D printer (Prusa i3 mk2 with standard PLA material. 1.75 nozzle, 0.15 layer height), to which we attached an Intersurgical Cleartherm-3 HME filter (Intersurgical, Wokingham, UK). The assembled system is illustrated in Fig. 1 . We subjected the system to a series of tests, firstly to check clinical applicability, and secondly to test fit. Quantitative fit-testing was conducted using the TSI Of great concern, however, was that the mask failed the quantitative fit-testing process despite the apparently successful fit-check. To permit formal fit-testing, we mounted a sampling line between the mask-adaptor and the filter using standard breathing system parts, such that Personal protective equipment during the COVID-19 pandemic -a narrative review 14B/ref=ppx_yo_dt_b_asin_title_o06_s00?ie=UTF8&psc=1 Guidance on respiratory protective equipment (RPE) fit testing. London: Her Majesty's Stationery Office