key: cord-0940216-vqu4qhu7 authors: Yang, G.; Benson, R.; Pelish, T.; Brown, E.; Winchell, J.M.; Fields, B. title: Dual detection of Legionella pneumophila and Legionella species by real-time PCR targeting the 23S-5S rRNA gene spacer region date: 2014-12-12 journal: Clin Microbiol Infect DOI: 10.1111/j.1469-0691.2009.02766.x sha: 913947b9629eb88d1777447affa49a1f45de7e46 doc_id: 940216 cord_uid: vqu4qhu7 Although the majority of cases of Legionnaires’ disease (LD) are caused by Legionella pneumophila, an increasing number of other Legionella species have been reported to cause human disease. There are no clinical presentations unique to LD and hence accurate laboratory tests are required for early diagnosis. Therefore, we designed a real-time PCR assay that targets the 23S-5S rRNA intergenic spacer region (23S-5S PCR) and allows for detection of all Legionella species and discrimination of L. pneumophila from other Legionella species. In total, 271 isolates representing 50 Legionella species were tested and the assay was validated using 39 culture-positive and 110 culture-negative patient specimens collected between 1989 and 2006. PCR-positive results were obtained with all 39 culture-positive samples (100% sensitivity). Specimens that tested positive according to 23S-5S PCR, but were culture-negative, were further analysed by DNA sequencing of the amplicon or the macrophage infectivity potentiator (mip) gene. In addition to L. pneumophila, Legionella longbeachae, Legionella cincinnatiensis and Legionella micdadei were identified in the specimens. The assay showed a 7-log dynamic range displaying a sensitivity of 7.5 CFU/mL or three genome equivalents per reaction. Sixty-one specimens containing viruses or bacteria other than Legionellae were negative according to 23S-5S PCR, demonstrating its specificity. Use of this assay should contribute to the earlier detection of respiratory disease caused by Legionella species, as well as to increased rates of detection. Legionellae are ubiquitous in natural and man-made aqueous environments. To date, at least 52 Legionella spp. have been identified (http://www.bacterio.cict.fr/l/legionella.html). Twenty-three species have been found to be associated with human diseases [1, 2] . Approximately 80-90% of reported cases of Legionnaires' disease (LD) are attributed to Legionella pneumophila; however, all species may cause infection, especially in immunocompromised hosts [1, 3, 4] . Legionnaires' disease has no unique clinical or radiographic features [5, 6] , which may lead to inappropriate therapy and a poor prognosis. Therefore, a validated and rapid diagnostic assay is of great importance. Current laboratory criteria for ensuring a confirmed diagnosis of LD involve isolating Legionellae by culture and detecting L. pneumophila serogroup 1 antigen in urine or seroconversion. Although these methodologies have good specificity, they primarily detect L. pneumophila. Non-pneumophila Legionella spp. may grow on buffered charcoal yeast extract (BCYE) media, but it usually takes approximately 1-2 weeks of incubation time for identification. Some strains, such as Legionella-like amoebal pathogens, are very fastidious and require amoebal co-culture [7] , which is laborious and impractical for clinical diagnosis. Therefore, infections caused by non-pneumophila species may not be diagnosed. To address these deficiencies, molecular assays that target the nucleic acid of Legionellae have been developed, but their applications in clinical diagnosis are still limited. For example, the proportion of cases diagnosed by PCR and other genotypic methods in Europe from 1995 to 2004 accounts for < 2% of cases of LD (n = 27 244) [8] . Reluctance to use PCR assays for diagnosis is partially attributable to: (i) postamplification procedures that are laborious, time-consuming and prone to carry-over contamination and false positivity, and (ii) limited assay optimization and validation. Here, we present a real-time PCR assay that allows rapid detection and differentiation of L. pneumophila from 50 non-pneumophila species without the need for post-PCR manipulation. The assay has been optimized to ensure sensitivity and specificity and validation has been carried out using culture isolates and clinical specimens. This assay should increase the rate of detection of infection caused by non-pneumophila strains of Legionellae and contribute to early diagnosis of LD. Legionella strains were grown on BCYE agar at 35°C with 2.5% CO 2 for 48-72 h. The incubation period for the culture of human specimens was 7 days. The bacteria derived from a single colony were harvested in water and subjected to genomic DNA purification. Primers targeting the 23S-5S rRNA intergenetic spacer region conserved for all Legionella species were designed. The sequences of forward and reverse primers were 5¢-GTA CTA ATT GGC TGA TTG TCT TGA CC-3¢ and 5¢-CCT GGC GAT GAC CTA CTT TCG-3¢, respectively. Two probes were designed within the amplicon region. One is specific for L. pneumophila (5¢-CalOrg-ATC GTG TAA ACT CTG ACT CTT TAC CAA ACC TGT GG-3¢BHQ); the other recognizes all known Legionella species (5¢-FAM ATC TC''G'' AA''C'' T''C''A ''G''AA ''G''T''G'' AAA C-3¢BHQ) ('''' denotes lock nucleic acid) and is referred to as the genus-wide probe or Legionella spp. probe. All PCR reactions were performed in triplicate using the AgPath-ID One-Step RT-PCR kit (AM1005; Applied Biosystems, Inc., Foster City, CA, USA) and the 7900HT real-time PCR system (Applied Biosystems, Inc.) unless otherwise indicated. Genomic DNA was purified from L. pneumophila serogroup 1 using the KingFisher ML instrument (Thermo Fisher Scientific, Inc., Waltham, MA, USA) and the InviMag kit (B-Bridge International, Inc., Sunnyvale, CA, USA) following the manufacturers' instructions. Genome equivalent (gEq), or single copy of genome, was calculated using a genome size of 3.397 · 10 6 bp (GenBank accession no. NC_002942). Ten-fold serial dilutions of the genomic DNA spanning seven orders of magnitude were amplified using optimized primers and probes. To determine the lower limit of detection (LLOD) for live bacteria, ten-fold serial dilutions of L. pneumophila serogroup 1 were streaked on BCYE plates. Bacterial colonies were manually counted. Colony counts of > 120 or < 20 were excluded from analysis. The bacteria were suspended in water and diluted to c. 100 CFU/mL. Genomic DNA was extracted as above from 1.5 mL of bacterial suspension. Five per cent of the purified DNA samples (n = 30) corresponding to c. 7.5 CFU/mL were amplified using the 7900HT realtime PCR system. In total, 149 clinical specimens from 67 patients with respiratory disease possibly caused by Legionella infection were tested. The specimens were collected over a 17-year period ( Table 1) . Cultures were performed on BCYE or selective media upon receipt. Retrospective studies were carried out using the remaining specimens, which had been stored at ) 80°C, to validate the 23S-5S PCR assay. Analysis of the mip sequence was performed on all culture-negative, but PCR-positive, samples unless otherwise indicated (Table 1) using the 3130XL Sequencer and BigDye X Terminator reagent and purification kit (Applied Biosystems, Inc.). The sequences were aligned with those in the National Center for Biotechnology Information (NCBI) database or the online mip-based Legionella identification tool (http://www. hpa-bioinfotools.org.uk/mip_ID.html). Real-time PCR for the human RNase P gene was carried out in parallel to monitor reaction inhibition and DNA integrity. The 149 patient specimens corresponded to 11 sample types ( Table 1 ). The assay allowed detection of Legionella spp. in all 39 culture-positive specimens. Moreover, Legionellae were identified in 27 of 110 culture-negative samples. Specimens that were 23S-5S PCR-positive but culture-negative were confirmed by sequencing the amplicon or by amplifying the mip gene, which was subsequently sequenced [9] . Among the 27 culture-negative samples, 15 were positive for L. pneumophila, two were positive for Legionella longbeachae, one was positive for Legionella cincinnatiensis and one was positive for Legionella micdadei. Amplicon sequence analysis of mip or 23S-5S did not reveal significant homology with any known Legionella spp. in seven samples, suggesting potentially novel Legionella spp. (R. M. Ratcliff, personal communication, 2008). One sample was depleted and no sequence analysis was performed. One set of primers and two probes were designed within the same region, resulting in a singleplex dual-colour realtime PCR (Fig. 1a) . PCR reactions were performed using the primers at working concentrations of 25-200 nM at two-fold intervals. The sensitivity was three orders of magnitude lower if the primer concentration was < 100 nM. The lowest cycle threshold (Ct) occurred with forward/reverse primers at 100 nM and 200 nM, respectively. Increasing the concentration from 200 nM to 800 nM did not improve sensitivity as Ct values remained nearly unchanged (p < 0.05). The probes were titrated similarly from 50 nM to 600 nM. Use of the Legionella spp. probe at a concentration of 200 nM gave the best performance and increasing the concentration to 400 nM did not reduce the Ct values. The L. pneumophilaspecific probe performed better at 400 nM. Higher probe concentration resulted in decreased sensitivity (data not shown). Linear regression analysis of the standard curves showed excellent correlation between the Ct value and the copy number of the Legionella genome (R 2 = 0.997) over seven orders of magnitude. The efficiency of amplification was 100.7% and 102.6% for L. pneumophila and the genus-wide assays, respectively (Fig. 1b) . The primers target the specific sites, even in the presence of high concentrations of Legionella genomic DNA (Fig. 1c) . The analytical sensitivity was assessed by amplifying L. pneumophila serogroup 1 DNA at a concentration of 3 gEq per PCR reaction. All samples were positive using the Legionella spp. probe (n = 20; Ct = 34.59 ± 0.76, coefficient of variation (CV) 2.22%) and 95% of the samples were positive using the L. pneumophila probe (n = 20; Ct = 35.51 ± 0.96, CV = 2.69%). By contrast, no signals were detected from no-template controls (NTCs) (n > 100) after 40 cycles of amplification. Therefore, the LLOD of the assay was c. 3 gEq per PCR reaction. For live bacteria, the assay detected L. pneumophila serogroup 1 at 7.5 CFU/mL (n = 30; for the Legionella spp. probe: Ct = 33.83 ± 0.52, CV = 1.53%; for the L. pneumophila probe: Ct = 37.05 ± 0.92, CV = 2.48%). No amplification was detected in the NTCs (n = 10). Genomic DNA isolated from the 271 strains representing the 50 Legionella spp. listed in Table 2 were amplified and detected using the Legionella spp. probe and the L. pneumophila-specific probe. The L. pneumophila probe did not crossreact with any non-pneumophila species and accurately detected L. pneumophila, despite the presence of high concentrations of genomic DNA. Total nucleic acid (TNA) was purified from 61 bacterial and viral strains (listed in Materials and methods). The TNA quality was demonstrated by corresponding PCR amplifications. Although the concentration of the templates was relatively high (5 ng, or c. 1 · 10 7 gEq for an organism with a genome size of 3.0 · 10 6 bp (GenBank accession no. NC_002942), none of the strains reacted with the Legionella probes, yielding an analytical specificity of 100%. The urine antigen (UA) test is increasingly used by clinicians in the diagnosis of LD, but it is limited to the detection of L. pneumophila serogroup 1 [10] . Extensive use of the UA test has resulted in a decrease in the use of other diagnostic methods, thus reducing the frequency of identification of species other than L. pneumophila serogroup 1 [11] . For example, a recent study of population-based surveillance of severe pneumonia in Thailand found no cases of L. pneumophila serogroup 1 infection using a UA test, but serological evidence suggested that approximately 5% of cases of pneumonia may be caused by L. longbeachae (n = 397) [12] . This underscores the need for diagnostic tests for all Legionella spp. In this study, we developed and validated a 23S-5S dualcolour real-time PCR assay. The LLOD of the assay was 3 gEq/reaction for genomic DNA or 7.5 CFU/mL for the live Legionella strain. It can distinguish L. pneumophila from nonpneumophila Legionella spp. and can detect Legionella spp. from all culture-positive clinical specimens within 3 h without requiring post-PCR processing steps. We assessed the specificity of the assay by analysing the DNA sequence of the amplicon or the mip gene and by assessing the reactivity with the non-Legionella bacteria and viruses. Legionella is not part of the human flora; thus, the presence or absence of Legionella DNA in specimens could be clinically significant. In recent years, molecular methods based on nucleic acid testing (NAT) have been extensively explored for diagnosis of LD. Overall NAT can be assigned to four types of assay: (i) PCR amplification of the whole genome followed by restriction enzymatic digestion and gel analysis [13, 14] ; (ii) PCR amplification of specific regions of the genome followed by sequencing analysis [15, 16] ; (iii) DNA hybridization or fluorescent in situ hybridization (FISH) [17] [18] [19] , and (iv) real-time PCR assays targeting 16S rRNA, the mip gene or the 23S-5S intergenetic region [20] [21] [22] [23] . A high rate of recombination in the 16S rRNA gene results in multiple heterogeneous copies in the genome, which may lead to erroneous species identification [24, 25] . The Legionella mip gene is highly variable, which makes designing a consensus probe to recognize all Legionella spp. virtually impossible [9] . The relatively conserved 23S-5S region allows the selection of primers and probes to detect L. pneumophila and Legionella spp. in a singleplex format. Three singleplex real-time PCR assays for identifying and differentiating L. pneumophila from other Legionella spp. have been reported [20] [21] [22] . These tests either require sequencing or melting curve analysis to distinguish L. pneumophila from other species, or lack specificity or validation using clinical specimens [20] [21] [22] . The availability of suitable patient samples for Legionella nucleic acid detection is limited. Oral pharyngeal swabs or nasopharyngeal swabs that are routinely taken from patients with respiratory infections may be less than ideal for Legionella-specific PCR testing unless the burden of Legionellae is high [26] . Collection of serum or urine samples is simple to perform, but the reported sensitivity varies from 30% to 86% for urine samples [27] [28] [29] and is < 60% for serum samples from patients with proven LD [30] . It appears that Legionella DNA in serum only peaks in the acute stage of infection [30] . In this study, the sensitivity observed with the archived serum samples was < 30% (data not shown). Bronchoalveolar lavage fluid, bronchial aspirates, lung biopsies, post-mortem tissue specimens and sputum appear to be more suitable for culture and PCR, but most of these specimens are not readily obtainable and are not usually taken for diagnosis [6, 31] . Nevertheless, these clinical specimens are valuable for validation of this diagnostic assay. The level of the impurities, such as human genomic DNA, protein and carbohydrates, varies among different types of specimen, and pathogen concentration in a clinical sample is significantly lower than that in laboratory cultures. Culture provides definitive diagnosis and remains a reference standard for Legionellae identification, but its use in the diagnosis of LD continues to decline. The clinical samples used in this study and in others [21] [22] [23] were positive only for L. pneumophila, suggesting that some non-pneumophila species were not detected by culture (L. cincinnatiensis, L. longbeachae and L. micdadei). Serological testing is generally limited to epidemiological studies and is unsuitable for diagnosis of acute LD because seroconversion does not occur until 2 weeks after the onset of illness and may even be absent in some patients [32] . In addition, the serological heterogeneity of Legionella spp. and antibody cross-reactions can lead to false-negative or false-positive results [33] . The goal of this study was to develop a molecular assay as a supplemental tool for diagnosis of LD caused by Legionella spp. The absence of unique clinical features or radiographic patterns complicates the diagnosis of LD. Among the 149 Strains, n lung specimens collected from patients with possible LD, Legionella spp. was detected in only 44% of cases. It is possible that the infection in these patients was caused by other pathogens. For example, we detected Pseudomonas aeruginosa, Sphingomonas spp. and Eubacterium spp. in some culturenegative samples using 16S rRNA PCR and sequencing analysis (data not shown). In conclusion, we have established a sensitive and specific real-time PCR assay that allows the detection of L. pneumophila and its differentiation from non-pneumophila species. Use of this assay in conjunction with currently recommended diagnostic tests should lead to increased rates of detection of respiratory disease caused by Legionella species. Infection due to Legionella species other than L. pneumophila Amoeba-associated microorganisms and diagnosis of nosocomial pneumonia Potential importance of Legionella species as aetiologies in community-acquired pneumonia (CAP) communityacquired and nosocomial infections Evaluation of the Hospital Winthrop-University criteria to identify Legionella pneumonia Legionella and Legionnaires' disease: 25 years of investigation Legionella drozanskii sp. nov., Legionella rowbothamii sp. nov., Legionella fallonii sp. nov.: three unusual new Legionella species Legionella spp., Legionnaires' disease Sequence-based classification scheme for the genus Legionella targeting the mip gene Comparison of the Binax Legionella urinary antigen enzyme immunoassay (EIA) with the Biotest Legionella urine antigen EIA for detection of Legionella antigen in both concentrated, non-concentrated urine samples Trends in Legionnaires' disease, 1980-1998: declining mortality, new patterns of diagnosis Epidemiology of severe pneumonia caused by Legionella longbeachae, Mycoplasma pneumoniae, Chlamydia pneumoniae: 1-year, population-based surveillance for severe pneumonia in Thailand Typing of Legionella pneumophila strains by reaction-mediated polymerase chain fingerprinting DNA Identification of Legionella species by ribotyping, other molecular methods Analysis of the genetic diversity of Legionella by sequencing the 23S-5S ribosomal intergenic spacer region: from phylogeny to direct identification of isolates at the species level from clinical specimens The use of 16S ribosomal RNA analyses to investigate the phylogeny of the family Legionellaceae Evaluation of the microplate hybridization method for rapid identification of Legionella species Rapid diagnosis of Legionella infection by a non-isotopic in situ hybridization method Mixed lung infection by Legionella pneumophila, Legionella gormanii detected by fluorescent in situ hybridization Identification, differentiation of Legionella pneumophila, Legionella spp. with real-time PCR targeting the 16S rRNA gene, species identification by mip sequencing Direct detection, differentiation of Legionella spp., Legionella pneumophila in clinical specimens by dual-colour real-time PCR, melting curve analysis Real-time PCR assay targets the 23S-5S spacer for direct detection, differentiation of Legionella spp., Legionella pneumophila Development, clinical evaluation of an internally controlled, single-tube multiplex real-time PCR assay for detection of Legionella pneumophila, other Legionella species Intragenomic heterogeneity, intergenomic recombination among Vibrio parahaemolyticus 16S rRNA genes Atypical 16S rRNA gene copies in Ochrobactrum intermedium strains reveal a large genomic rearrangement by recombination between rrn copies Are oropharyngeal swabs suitable as samples for Legionella-specific PCR testing? Use of the polymerase chain reaction to detect Legionella DNA in urine, serum samples from patients with pneumonia Diagnostic relevance of the detection of Legionella DNA in urine samples by the polymerase chain reaction Detection of Legionella pneumophila DNA in urine, serum samples from patients with pneumonia Evaluation of real-time PCR for the early detection of Legionella pneumophila DNA in serum samples Diagnosis of Legionella infection in Legionnaires' disease Timing of seroconversion in Legionnaires' disease Evaluation of the Legionella Duopath lateral flow assay for identification of Legionella pneumophila, Legionella species culture isolates We thank C. Whitney for her critical comments on our manuscript, and S. Schwartz, K. Thurman, M. da Gloria Carvalho, D. Erdman, M. Tondella and K. Tatti for providing viruses, DNA/RNA or bacteria strains. The authors have no conflicts of interest with commercial entities or any other third parties. L. pneumophila 66 2 L. adelaidensis 1 3L. anisa 18 4 L. beliardensis 1 5L. birminghamensis 5 6 L. bozemanae 31 7L. brunensis 1 8L. busanensis 1 9L. cherrii 3 10 L. cincinnatiensis 3 11L. drozanskii 2 12L. dumoffii 7 13L. erythra 3 14L