key: cord-0937156-slyzgjb0 authors: Rossi, Fabio; Tuci, Lorenzo; Ferraioli, Lorenzo; Ricci, Emanuele; Suerica, Andreea; Botticelli, Daniele; Pellegrino, Gerardo; Felice, Pietro title: Two-Year Follow-Up of 4-mm-Long Implants Used as Distal Support of Full-Arch FDPs Compared to 10-mm Implants Installed after Sinus Floor Elevation. A Randomized Clinical Trial date: 2021-04-06 journal: Int J Environ Res Public Health DOI: 10.3390/ijerph18073846 sha: cd6da1562801085962b3749979df47247a371f85 doc_id: 937156 cord_uid: slyzgjb0 Background: In edentulous patients, bone resorption cannot allow the installation of standard implants and it is demanded to use short implants in the residual alveolar bone or longer implants in grafted bone. Aim: To compare the survival and bone level changes of standard plus short 4-mm implants used as distal support of a maxillary full-arch fixed dental prostheses (FDPs) with standard (10-mm) implants placed in association with a bilateral sinus floor augmentation procedure. Material and Methods: Full-arch FDPs supported by six implants were randomly placed in both groups. In the control group, all implants were 10 mm long and 4.1 mm in diameter. The distal implant in both sides of the maxilla was installed after 4 months from bilaterally sinus floor elevation. In the test group (short group), the distal implant in both sides of the maxilla was 4 mm long and 4.1 mm in diameter. No sinus floor elevations were performed in the test group. Clinical assessments and X-rays were taken at prosthesis delivering and after 6, 12, 18, and 24 months. Patient-reported outcome measures (PROMs) were also evaluated before surgery and after 6, 12, and 24 months. Results: The changes over time of the bone level for the short implants were −0.01 ± 0.11 mm, −0.04 ± 0.13 mm, −0.17 ± 0.29 mm, and −0.28 ± 0.37 mm after 6, 12, 18, and 24 months from prosthesis delivering, respectively. For the standard implants, bone changes were −0.21 ± 0.33 mm (p = 0.103), −0.30 ± 0.32 mm (p = 0.023), −0.40 ± 0.37 mm (p = 0.144), and −0.54 ± 0.49 mm (p = 0.128), respectively. A statistically relevant difference was found only at 12 months after loading between the two groups. Conclusions: Similar results on implant survival rate and marginal bone loss were observed for the short and standard implants, placed in association with a bilateral sinus floor augmentation procedure, used as distal support of a maxillary full-arch FDP. A statistically relevant difference was found only at 12 months after loading between the two groups (p = 0.023). Anatomical limitations to implant insertion in fully edentulous arches are frequently encountered in the posterior regions of the jaws, due to the presence of the mandibular canal and of the maxillary sinus. In such situations, the installation of standard implants (≥10 mm) could be impossible. An alternative might be the use of the so-called "tilted implants" that might allow the use of standard implants [1] . Vertical augmentation [2] procedures or sinus floor elevation [3, 4] with a different approach [5] might allow the installation of standard implants as well. Another alternative is the use of short implants, as recommended in a consensus conference [6] for the lower occurrence of complications of this treatment compared to the use of longer dental implants installed in augmented sinus. Another consensus report concluded that the use of ≤6-mm-long implants are a valid option to be used as alternative to augmentation procedures to reduce morbidity incidence [7] . A recent article reported a high survival rate (91.7%) after 10 years of loading of 6-mm-long implants supporting single fixed dental prostheses (FDPs) in the posterior regions of both jaws [8] . Recently, 4-mm-long implants with a standard diameter have been used for the rehabilitation of the posterior edentulous mandible with favorable results [9, 10] . However, randomized control trials (RCTs) reporting the results from full-arch FDPs that included 4-mm-long implants placed in the posterior regions of the maxilla have not been published yet. Hence, we compared the survival and bone level changes of 4-mm-implants used as distal support of a maxillary full-arch FDPs with control (10 mm) implants placed in association with a bilateral sinus floor augmentation procedure. The Declaration of Helsinki was followed, and the protocol was approved by the Ethical Committee Interaziendale Bologna-Imola (protocol #15052; 9 September 2015). All procedures, timing, and complications were systematically explicated to the included participants, and signed informed consents were collected. The Consort checklist was followed for this report (http://www.consort-statement.org/, accessed on 22 May 2019). The study was registered in the ClinicalTrials.gov with the following identifier: NCT03958448. This research is an RCT where short dental implants 4 mm long are compared with longer dental implants 10 mm long in association with SFE-Sinus Floor Elevation. Patients recruited needed full-arch fixed maxilla rehabilitation. Patients suffering severe atrophy in the distal part of the maxilla and two approaches were established. Test patients received super-short 4-mm-long implants as distal support of the FDPs. On the other side, control patients received the same fixed prosthesis rehabilitation, but in the distal atrophic maxilla before placing 10-mm-long implants as distal support, bilateral SFE was performed. Results during healing time and follow-up were carefully registered. The present study was a parallel randomized control trial initially programmed to include 20 participants. Two groups were randomly arranged, the control and the short groups. Full-arch FDPs supported by six implants were randomly placed in both groups. In the control group, all implants were 10 mm long and 4.1 mm in diameter. The distal implant in both sides of the maxilla was installed 4 months after bilateral sinus floor elevation. In the test group (short group), the distal implant was 4 mm long and 4.1 mm in diameter in both sides of the maxilla. No sinus floor elevations were performed in the test group. Patients recruitment and all clinical procedures were performed at the Department of Biomedical and Neuromotor Sciences, Dental Clinic, University of Bologna, BO, Italy. The following inclusion criteria were adopted: Willing to receive a full arch fixed restoration in the maxilla. • Latest extraction at least 8 weeks before implant insertion. • Sinus floor height included between 4 to 6 mm. • Bone width in the distal segments enough to allow the insertion of a 4-mm-long implant of standard diameter. In the anterior maxilla (from first premolar to first premolar), bone width enough to allow the insertion of 10-mm-long implants of standard diameter. Minor horizontal augmentations with GBR-Guided Bone Regeneration procedures were allowed in the anterior maxilla. Moreover, the opposing arch had to present one of the following conditions: -Natural dentition (at least 10 elements from 3.5 to 4.5). -FDPs -Fixed dental prosthesis of at least 10 elements (from 3.5 to 4.5) supported by teeth or implants. -Implant-supported or teeth-supported overdentures. -Adequate partial removable prostheses. In the absence of sound data on bone level changes on short implants at the time of the proposal, the present was structured as a pilot study. A bone change of 1 mm over time was proposed to be clinically relevant. With a standard deviation of 0.5 mm, a power of 0.9, and an α = 0.05, ten patients each group were calculated to be enough to disclose differences, including possible dropouts. A statistician not involved in the study performed the randomization in blocks of four and the assignments were sealed in coded and opaque envelopes that were opened at the time of the enrollment of each patient in the study. The surgeon was blinded about the allocation of the treatment until the time of the installation. The patients were blinded about the treatment received. The implants were produced by Institute Straumann AG, Basel, Switzerland. A natural bovine bone grafting material (Cerabone granules 1-2 mm, Botiss biomaterial GmbH, Zossen, Germany) was used for sinus floor elevation. A porcine dermis collagen membrane (Collprotect membrane, Botiss biomaterial GmbH, Zossen, Germany) was used to cover the antrostomy. Bone fillers and collagen membranes are distributed by Institute Straumann AG, Basel, Switzerland. In each side of the posterior region of the maxilla, one 4-mm-long and 4.1 mm in diameter tissue level implant, with a neck of 1.8 mm height, was installed. In the frontal region, four bone level implants, 10 mm long and 4.1 mm or 3.3 mm in diameter, were used ( Figure 1A) . A non-submerged healing was allowed. Bilateral sinus floor elevations using a lateral access were performed using Cerabone as filler material and Collprotect to cover the antrostomy. After 4 months of healing, one bone level implant, 10 mm long and 4.1 mm in diameter, was installed into each augmented sinus. In the frontal region (included between the second premolars), four bone level implants, 10 mm long and 4.1 mm or 3.3 mm in diameter, were used ( Figure 1B) . A non-submerged healing was allowed. Amoxicillin and clavulanic acid were administrated per os before and for the following 6 days. As painkiller, Ibuprofen 600 mg per os was suggested if needed. During the healing, a temporary removable prosthesis was provided to the patients. Six weeks after implant installation, impressions were taken and a fixed metal ceramic full-arch screw-retained prosthesis was fabricated and delivered ( Bone quality according to Lekholm and Zarb [11] was subjectively evaluated and the insertion torque was assessed using a ratchet device (Institute Straumann AG, Basel, Switzerland), and categorized as follows: 0 ≤ 15, 15 < x < 35, and ≥35 Ncm. Bleeding on probing [12] and probing depths were assessed around short and control implants at prosthesis delivering and after 6, 12, 18, and 24 months. The highest probing depth was recorded and categorized as follows: 1-3 mm, 4-5 mm, ≥6 mm. X-rays applying a parallel technique were taken at implant installation, at prosthesis delivering (baseline) and after 6, 12, 18, and 24 months. The measurements on the digital X-rays were carried out twice by the same operator (L.T.) using the software Planmeca ROMEXIS®(Helsinki, Finland). The calibration of the measurements on the software was obtained using the full length of the implant. The operator presented an intra-class coefficient of correlation for intra-rater agreement >0.93 for marginal bone level radiographic analysis. The distance between the implant margin and the first bone to implant contact was measured at the mesial and distal aspects of the short and standard implants. The PROMs (patient-reported outcome measures) [13] were evaluated using a standardized questionnaire (Oral Health Impact Profile-20E; OHIP-20E) that included 20 questions and to each question the patient had to give a score. The frequency ranged between 1 (always) to 6 (never), and the questions were related to functional limitation, physical pain, physical disability, psychological discomfort, and social disability. The assessments were performed before surgery and after 6, 12, and 24 months. Mean values were calculated per each item and a total score for each group was assessed. Only the distal implants were included in the analysis. Mean values were obtained from the double measurements made at the mesial and distal aspects of each implant. Subsequently, mean values were calculated between the distal and mesial measurements for each implant. At the tissue level implants, the height of the polished neck (1.8 mm) was subtracted to obtain the level of the coronal margin of the rough surface. The marginal bone levels reported in the present article were related to the position of the coronal marginal rough surface. Marginal bone changes were calculated and differences between groups were evaluated at implant level using the U Mann-Whitney test included in the Statistics software Stata (IBM Inc., Chicago, IL, USA). The level of significance was set at α = 0.05. The primary variable was the change of marginal bone level between the baseline and 1 and 2 years of follow-up. The study started on 9 September, 2015 and it was interrupted in September 2020. Recruitment stopped due to the COVID-19 conditions, and five patients of the planned 20 were not included in the study. At that date, a total of fifteen patients were included. Considering 15 patients enrolled, only 11 patients, six short and five control, reached the 2-year follow-up, while four participants were excluded from analysis because they did not comply with the requirement in terms of follow-up ( Figure 3 , Table 1 ). No complications were detected during healing. No implant in the distal region of the FDPs was lost, while one implant was lost in the frontal region and replaced in a patient of the control group. In the same patient, another frontal implant presented signs of peri-implantitis after about 18 months of function and was surgically treated. The radiographic documentation was available for evaluation in 12 implants of the short group and 10 implants of the control group. The clinical assessments showed a maximum probing depth of ≤4 mm in both groups in all periods evaluated. At the baseline, the peri-implant mucosa showed bleeding on probing at one implant site of the short group. After two years of function, 3 out of 12 implant sites of the short group and one out of 10 implant sites of the control group presented bleeding on probing. No technical complications occurred after 2 years of function. Radiographic evaluation (Table 2) . At the baseline (prosthesis delivering), the mean bone level (MBL) was 0.17 ± 0.41 mm with regards to the short implants ( Figure 4A,B) , while for the control implants was 0.28 ± 0.21 mm (p = 0.007) ( Figure 5A,B) . The changes over time of the bone level for the short implants were −0.01 ± 0.11 mm, −0.04 ± 0.13 mm, −0.17 ± 0.29 mm, and −0.28 ± 0.37 mm after 6, 12, 18, and 24 months from prosthesis delivering, respectively ( Figure 4C,D) . For the control implants, bone change levels were −0.21 ± 0.33 mm (p = 0.103), −0.30 ± 0.32 mm (p = 0.023), −0.40 ± 0.37 mm (p = 0.144), and −0.54 ± 0.49 mm (p = 0.128), respectively ( Figure 5C,D) . A statistically relevant difference was found only at 12 months after loading between the two groups (p = 0.023); at the very end of the follow-up, no statistical differences were found between the two groups. The PROMs evaluation revealed a general satisfaction of the patients in both groups about functional limitation, physical pain, physical disability, psychological discomfort, and social disability after the rehabilitation (Table 3A,B) . No implants were lost after 2 years' follow-up. The survival rate of 4-mm implants used as distal support of maxillary full-arch FDPs was similar to that of 10-mm implants placed in association with a bilateral sinus floor augmentation procedure. This result agrees with other clinical studies [9, 10, [14] [15] [16] [17] . In a randomized controlled trial (RCT) [17] , eleven patients were rehabilitated bilaterally with FDPs supported by two to four 4-mm-long implants or by 8-or 10-mm-long implants installed in regenerated bone. After one year of follow-up, no implants were lost. In another RCT [15] , ten patients with edentulous mandible were rehabilitated with a screw-retained full complete denture. The prosthesis was supported by 10-mm-long implants installed in the intra-foramina region, and two 4-mm-long implants were installed bilaterally, distally to the foramina. One short implant was lost before loading and was substituted. All patients were rehabilitated and, after one year of follow-up, no further loss of implants was registered. In a multicentric RCT [9] , eighty patients with posterior edentulism were included. Forty patients presented 5-6-mm alveolar bone height above the mandibular canal and forty patients presented 4-5-mm of alveolar bone height below the maxillary sinus. The patients were randomly assigned either to receive 4-mm-long implants or an augmentation procedure. After one year of loading, one long implant and two short implants were lost in the mandible, while in the maxilla, three short implants and seven long implants were lost. In another multicenter RCT [16] , one hundred and fifty patients with an edentulous posterior region in the mandible and/or in the maxilla were rehabilitated with screwretained fixed prostheses supported by implants. A minimum height of 12.5 mm of alveolar bone above the mandibular canal or 11.5 mm below the sinus floor was required. Either short (4-mm) or ≥8.5-mm-long implants were randomly assigned to the patients. After one year of loading, three short and two long implants were lost before loading and replaced. No further loss of implants occurred after loading. In a prospective study [10] , twenty-eight patients were rehabilitated in the posterior mandible with FDPs supported by 4-mm-long tissue level implants. Eighty-six implants were installed, and the patients were followed up to 5 years. Five implants were lost between 3-5 years of loading. In a systematic review [18] , short (≤6 mm) and longer implants (≥10 mm) with sinus floor elevation were compared and analyzed. A total of seven RCTs involving 310 patients were included. The follow-up reached more than three years for several studies. Authors declared that no significant difference with regards to MBL and survival rate were found between each group at each time of the follow-up: 1 up to 3 years and more than 3 years. In the present study, at baseline, the marginal bone level was located more apically at the control long implants (0.28 mm) compared to the short implants (0.17 mm). The difference was statistically significant (p = 0.007). This might be related to an unintentional deeper positioning of the transmucosal short implant compared to the 10-mm-long implant, in an attempt to gain a better primary stability. After one year of loading, 0.04 mm and 0.30 mm of marginal bone loss was found for the short and control implants, respectively (p = 0.023). After 2 years of loading, the loss of marginal bone was 0.28 mm and 0.54 mm for the short and control implants, respectively (p = 0.128). The encouraging outcomes from the present study support the data reported in the studies mentioned above. In a prospective multicenter study [10] , after one year of loading, similar loss of marginal bone was reported for both short and long implants, ranging from 0.30 mm to 0.63 mm, and from 0.47 mm to 0.72 mm, respectively. These outcomes are also in agreement with other studies that compared 6-mm-with 10-mm-long implants supporting single crowns [19] . Only~0.1 mm and <0.2 mm of bone loss was observed after 1 and 5 years of loading at both short and long implants. In that study, three short implants were lost after loading. Similar minor loss of marginal bone was observed in both groups. However, a higher loss of implants occurred in the short, compared to the long, groups. The stability of the marginal bone and the sudden loss of stability of the implant/crown unit suggested that the loss of short implants probably owed to a fracture of the supporting alveolar bone. Nevertheless, in a prospective study on single crowns supported by 6-mm-long implants, two implants were lost before loading and only one implant was lost after 7 years of loading. However, a mean loss of 0.8 mm was observed after 10 years of function [8] . Ultimately, our results agree with what was reported by a recent literature review [20] where extra-short (4 mm) dental implants are compared with longer (8 mm) dental implants placed in conditions of severe bone atrophy, analyzing rehabilitations with splinted implants, as in our research project. Authors reported at the end of their review that extra-short implants exhibit satisfactory clinical outcomes concerning implant survival rate and MBL when compared to longer implants, with a low number of biological and prosthetic complications. However, this research also suggests the need to proceed with more in-depth analysis and follow-up. No technical complications were reported in the present study. This is in agreement with other studies that used the same implant system and had very few technical complications [8, 10, 15, 17] . The patients of both groups reported an improvement of the parameters, as evaluated with OHIP-20E, after prosthesis delivering. However, a trend of higher satisfaction was shown in the short group compared to the control group. This might be related to the higher complexity and extended length of the treatment in the latter compared to the former group. In another clinical trial, single crowns supported by either short implants or standard implants in combination with sinus floor elevation were evaluated [21] . After 5 years of function, no statistically significant differences were found in the PROMs between the two groups. The different scores compared to the present study might be related to the different type of restoration and follow-up. As limitation of the present study, it should be mentioned the different geometry design of the two groups of implants, that might have influenced both the positioning at the surgery and the following healing. Moreover, both short and long implants were connected to a full arch bridge, and this might have contributed to the stability over time. A longer follow-up is needed to confirm the results. As our main focus and outcome in this article were survival rate and bone loss around implants, we did not statistically evaluate the score changes for each question over time of the PROMs questionnaire. We reported the data in a more descriptive way, and this might be a limitation too. The present study reported similar results on implant survival rate and marginal bone loss for 4-mm-and 10-mm-long implants, placed in association with a bilateral sinus floor augmentation procedure, used as distal support of a maxillary full-arch FDP. Analysing OHIP-20E, a much greater satisfaction was registered in both groups after rehabilitation, but higher scores were obtained in the short group. Author Contributions: Conceptualization, F.R.; methodology, F.R., L.F., E.R., and G.P.; validation, F.R., E.R., G.P., and P.F.; formal analysis, L.T. and D.B.; investigation L.T. and A.S.; data curation, L.T. and A.S.; writing, original draft preparation, review and editing, visualization, supervision, all authors involved. Project administration, F.R. and P.F.; funding acquisition, F.R. All authors have read and agreed to the published version of the manuscript. Institutional Review Board Statement: The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Ethics Committee of Bologna-Imola (protocol code 15052), 09 September 2015. All procedures, timing, and complications were systematically explicated to the included participants, and signed informed consents were collected. The Consort checklist was followed for this report (http://www.consort-statement.org/, accessed on 22 May 2019). The study was registered in the ClinicalTrials.gov with the following identifier: NCT03958448. Informed Consent Statement: Informed consent was obtained from all subjects involved in the study. Written informed consent has been obtained from the patient(s) to publish this paper. The study was registered in the ClinicalTrials.gov with the following identifier: NCT03958448. Biological and technical complications of tilted implants in comparison with straight implants supporting fixed dental prostheses. A systematic review and meta-analysis Vertical Guided Bone Regeneration using Titanium-reinforced d-PTFE Membrane and PrehydratedCorticocancellous Bone Graft Long-term effectiveness of maxillary sinus floor augmentation: A systematic review and meta-analysis Effectiveness of sinus lift procedures for dental implant rehabilitation: A Cochrane systematic review Distal Displacement of Maxillary Sinus Anterior Wall Versus Conventional Sinus Lift with Lateral Access: A 3-Year Retrospective Computerized Tomography Study EAO Supplement Working Group 4-EAO CC 2015 Short implants versus sinus lifting with longer implants to restore the posterior maxilla: A systematic review Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient-reported outcomes Long-term follow-up of single crowns supported by short, moderately rough implants-A prospective 10-year cohort study 4 mm long vs longer implants in augmented bone in posterior atrophic jaws: 1-year post-loading results from a multicentrerandomised controlled trial Four-Millimeter-Long Posterior-Mandible Implants: 5-Year Outcomes of a Prospective Multicenter Study Patient selection and preparation Bleeding on probing. A predictor for the progression of periodontal disease? Group 3 ITI Consensus Report: Patient-reported outcome measures associated with implant dentistry Clinical Pilot Study with Eleven 4-Mm Extra-Short Implants Splinted to Longer Implants for Posterior Maxilla Rehabilitation Evaluation of extrashort 4-mm implants in mandibular edentulous patients with reduced bone height in comparison with standard implants: A 12-month results Four mm-long versus longer implants in augmented bone in atrophic posterior jaws: 4-month post-loading results from a multicentrerandomised controlled trial Comparing 4-mm dental implants to longer implants placed in augmented bones in the atrophic posterior mandibles: One-year results of a randomized controlled trial Short implants (≤6 mm) versus longer implants with sinus floor elevation in atrophic posterior maxilla: A systematic review and meta-analysis Early loading of 6-mm-short implants with a moderately rough surface supporting single crowns-A prospective 5-year cohort study Clinical Comparation of Extra-Short (4 mm) and Long (>8 mm) Dental Implants Placed in Mandibular Bone: A Systematic Review and Metanalysis Randomized controlled multicentre study comparing short dental implants (6 mm) versus longer dental implants (11-15 mm) in combination with sinus floor elevation procedures: 5-Year data Gratitude for the scientific support is due to Luca Cordaro, Eastman Hospital, Rome and to Agnese Ferri, Alma Mater Studiorum, Bologna University, Italy for the support in statistical assessments. Gratitude for technical support and prosthesis production to Sig. Stefano Zorzan, Zorzan Technical Lab-Bologna. The authors declare no conflict of interest.