key: cord-0936918-hspwbila authors: Lin, Li-Wei; Chong, Chee-Fah title: Saliva ejector assisted laryngoscopy (SEAL) for protective intubation date: 2020-07-04 journal: Am J Emerg Med DOI: 10.1016/j.ajem.2020.06.041 sha: ed817c667e7b1e9d118a3811ff2faa6f0672317e doc_id: 936918 cord_uid: hspwbila nan To the Editor, Unprotected endotracheal intubation in suspected or confirmed cases of SARS-CoV2 infection may put healthcare providers at risk of droplet or airborne infections [1, 2] . We describe a potential method for reducing provider exposure during intubation using a saliva ejector suction system. This aerosol-reducing method has an easy-toremember acronym: "SEAL" (saliva ejector assisted laryngoscopy). A saliva ejector (Fig. 1A) is a tubular device providing suction to remove saliva and debris from the mouth of a dental patient in order to maintain a clear operative field. The ejector is usually curved into a J-shaped configuration before its use. It comprises an inlet (the shorter arm of the J) placed in the mouth cavity and an outlet (the stem of the J) connected to a vacuum source via a flexible hose (Fig. 1B) . In our simulation, airway droplets and aerosols were approximated with water vapor generated at 15 L/min using a conventional nebulizer connected to the airway of a mannequin. A disposable saliva ejector was placed over the left commissure of the mouth with its suction tip positioned in between the soft palate and the tongue. The outlet of the saliva ejector was connected to a wall-mounted vacuum suction regulator (Fig. 1B) . When the vacuum source was turned off, vapor was visible from the mouth (Fig. 1C) . Once the vacuum was turned on, the vapor was no longer visible (Fig. 1D, Video 1) . Our proposed SEAL technique has some limitations. Though routinely available at dental clinics, the saliva ejector may not be obtainable at some EDs. Normal suction devices are less suitable for similar purpose because they cannot be shaped into the J-configuration of the saliva ejector (to be properly hung over the mouth angle for aerosol suction). Although visible vapor can be reduced in a manikin model, the effectiveness of this technique in reducing COVID-19 exposure is unclear and further studies in the clinical environment are needed prior to its application in practice. The effect of this technique on positive-end expiratory pressure among COVID-19 patients is unclear. Providers should consider avoiding this technique in patients who are dependent on PEEP prior to the intubation. Supplementary data to this article can be found online at https://doi. org/10.1016/j.ajem.2020.06.041. Barrier enclosure during endotracheal intubation Protecting health-care workers from subclinical coronavirus infection The authors thank Dr. James DuCanto (Advocate Aurora St. Luke's Medical Center, Department of Anesthesiology, Milwaukee, Wisconsin) for his invaluable guidance.