key: cord-0936774-pnxbifyn authors: Büyüksünetçi, Yudum Tepeli; Çitil, Burak Ekrem; Tapan, Utku; Anık, Ülkü title: Development and application of a SARS-CoV-2 colorimetric biosensor based on the peroxidase-mimic activity of γ-Fe(2)O(3) nanoparticles date: 2021-09-09 journal: Mikrochim Acta DOI: 10.1007/s00604-021-04989-6 sha: efb71c1f624393543bf3e0f7e6ec0064a7c3546b doc_id: 936774 cord_uid: pnxbifyn A practical colorimetric assay was developed for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). For this purpose, magnetic γ Fe(2)O(3) nanoparticles were synthesized and used as a peroxidase-like mimic activity molecule. In the presence of γ Fe(2)O(3) nanoparticles, the color change of H(2)O(2) included 3,3′,5,5′-tetramethylbenzidine was monitored at the wavelength of 654 nm when spike protein interacted with angiotensin-converting enzyme 2 receptor. This oxidation-reduction reaction was examined both spectroscopically and by using electrochemical techniques. The experimental parameters were optimized and the analytical characteristics investigated. The developed assay was applied to real SARS-CoV-2 samples, and very good results that were in accordance with the real time polymerase chain reaction were obtained. [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-021-04989-6. The latest coronavirus severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) or COVID-19 is the seventh member of the coronavirus family [1] . Like the other previous two viruses in this family, namely, severe acute respiratory syndrome coronavirus (SARS-CoV) and Middle East respiratory syndrome coronavirus (MERS-CoV), SARS-CoV-2 is a positive-sense, non-segmented, and an enveloped RNA virus [2] . It has single strands of RNA and crown-like spikes on the outer surface [3] . Four types of main proteins, namely, spike (S), membrane, envelope, and nucleocapsid [4] , are the proteins that are found in SARS-CoV-2. The glycoprotein, Sprotein of SARS-CoV-2, is made up of 2 subunits, namely, S1 and S2. S1 has the receptor-binding domain (RBD) part which provides the attachment of the virus to the receptor while S2 facilitates the virus cell membrane fusion [3, [5] [6] [7] . S1 subunit has a kind of open conformation which helps it to interact with angiotensin-converting enzyme 2 (ACE2) [7] [8] [9] . ACE2 is found in the membranes of the lungs, arteries, heart, kidney, and intestine cells [10, 11] . ACE2 also acts as an entry point for some coronaviruses, such as SARS-CoV and SARS-CoV-2 [12] . Although SARS-CoV and MERS have higher fatality rates compared to SARS-CoV-2 [13] , since SARS-CoV-2 is more infectious, the overall number of deaths is much higher than SARS-CoV and MERS. For this reason, early and effective detection of SARS-CoV-2 becomes more important day by day. Currently, laborious, time-consuming, and specialized personnel needed realtime polymerase chain reaction (RT-PCR) technique is the gold standard method for SARS-CoV-2 detection. Due to the disadvantages mentioned above, accurate, rapid, and practical methods that have a point of care (POC) nature are urgently needed [14] . Conducting the diagnostic test at home without needing to leave the house and learning the result rapidly, will allow a person to quarantine himself immediately thus preventing the spread of the virus. Apart from these, it is also stated that there are asymptomatic or paucysymptomatic cases in the early stages of the infection, and such cases are the cause of transmission [15] [16] [17] . In this context, for SARS-CoV-2 detection, many attempts have been made in terms of appropriate biosensor developments, which are usually based on antigen-antibody interactions [4, 14, 18] . Also, suitable rapid tests have been developed and used for this purpose [19] . The highly insufficient sensitivity value in rapid antibody tests, which was seen as a hope in active case detection, also decreases the value of these tests [19] . Herein, we manage to develop a novel colorimetric assay for SARS-CoV-2 detection. The interactions are based on the infection mechanism of SARS-CoV-2 which we believe differs from the other antigen-based rapid tests or biosensors. For this purpose, we used magnetic γ Fe 2 O 3 nanoparticles as a peroxidase-like mimic activity providing molecule [20] and monitor 3,3′,5,5′-tetramethylbenzidine (TMB) colorimetric reagent oxidation-reduction reactions [21, 22] when Sprotein interacted with ACE2 receptor. Lastly, developed assay was applied for real sample analysis where the validation was done via RT-PCR method. All reagents were of analytical grade and used without any purification. Sodium hydroxide (NaOH), hydrogen chloride (HCl), nitric acid (HNO 3 T60UV modeled PG instruments limited UV-Vis spectrophotometer was used to measure the absorbance of samples by using 1 cm quartz cuvettes. Scanning electron microscopy (SEM) image and energy dispersive X-ray spectroscopy (EDS) measurements were obtained from JSM-7600 F FEG-SEM at 15.0 kV. X-ray Powder Diffraction (XRD) measurements were carried out with the Rigaku Smartlab XRD apparatus. F o r R T -P C R , " B i o -S p e e d y ® S A R S -C o V -2 + VOC202012/01 RT-qPCR" kit was used which was obtained from Bioeksen R&D Technologies Istanbul-Turkey. The amplification was performed on a CFX96 Touch Real-Time PCR Detection System Instrument (Bio-Rad Laboratories, Inc., USA). vNAT® tubes were also used from Bioeksen R&D Technologies Istanbul-Turkey (extraction consumables of vNAT® Viral Nucleic Acid Buffer Cat No BS-NA-510; vNAT® Transfer Tube Cat No BS-NA-513-100-Bioeksen R&D Technologies Istanbul-Turkey). The enzyme-mimicking activity of γ Fe 2 O 3 Synthesis and characterization experiments of γ Fe 2 O 3 magnetic nanoparticles are detailed in the supplementary file [23, 24] . The peroxidase-like mimic activity of magnetic γ Fe 2 O 3 nanoparticle in the presence of hydrogen peroxide (H 2 O 2 ) was well known [20, [25] [26] [27] . Herein, we used TMB (Cat. No. T0440) that has already contained H 2 O 2 , a ready to use Enzyme-Linked Immuno Sorbent Assay (ELISA) test [28, 29] . For this reason, in our assay, the oxidation of colorless TMB solution to the blue color oxidized TMB (Ox) solution was obtained without adding any H 2 O 2 to the medium. For clear observation of color change, 1 mL of TMB solution and 50 μL of magnetic γ Fe 2 O 3 nanoparticle colloid were mixed and waited for 1 h. During this process, the solution was constantly in contact with air, and intermittent shaking was carried out to prevent the magnetic γ Fe 2 O 3 nanoparticles from settling to the bottom. In the presence of magnetic γ Fe 2 O 3 nanoparticles, the oxidation progress of TMB to TMB (Ox) was monitored by measuring the absorbance of the reaction mixture using a UV-visible spectrophotometer in a range of 450-800 nm. For determination of S-protein, the first blue-colored TMB (Ox) form was obtained by mixing 1 mL of TMB (optimized amount, data not shown) and 50 μL (10 mg.mL −1 ) of magnetic γ Fe 2 O 3 nanoparticles [24] in the Eppendorf tube for 1 h. After TMB was completely transformed into TMB (Ox) , 100 μL from 10 ng.mL −1 of ACE2 receptor (the optimal binding function concentration specified in the data sheet) was added into the blue colored mixture. Then, different concentrations of S-protein solution were added to the blue colored mixture and incubated constantly in contact with air and intermittent shaking for 30 min. For UV measurements, at the end of the incubation time, a colorless or light blue colored mixture was transferred to a 1 cm path length quartz cuvette, and a magnet was placed under the cuvette to keep the magnetic γ Fe 2 O 3 nanoparticles at the bottom of the cuvette. Magnetic separation was performed before each UV-vis measurement to avoid scattering caused by magnetic nanoparticles (Scheme 1). For the real sample analysis, after completing ACE2 incubation, real samples were added to the medium instead of S-protein. Selectivity studies of the developed colorimetric SARS-CoV-2 biosensor were performed with influenza A virus. H3N2 Brisbane virus and H1N1 New Caledonia virus were selected as model influenza A viruses. In order to observe the influenza viruses interfering effects, 48.70 ng.mL −1 virus solutions and S-protein solution were added to the solution that contained 1 mL of TMB, 50 μL of magnetic γ Fe 2 O 3 nanoparticles, and 100 μL ACE2 (from 10 ng.mL −1 ACE2 solution). After waiting at 25°C for 30 min, experiments were carried out in triplicate. Combined oropharyngeal and nasopharyngeal swab specimens were collected from samples received at the microbiology department of the Muğla Training and Research Hospital, a tertiary hospital of more than 600 beds in Muğla. The samples included in the study were selected from those who were requested to be tested in the routine COVID-19 diagnostic procedure in the laboratory. The validity of our colorimetric biosensor was tested by analyzing real samples that were previously investigated by RT-PCR. The threshold level was chosen as 200 RFU (relative fluorescence units) to calculate the number of threshold cycle (Cq) in accordance with the manufacturer's recommendations. The samples were collected from 41 positive SARS-CoV-2 patients for which Cq ≤ 33 and 41 negative patients (no Cq detection). Combined nasopharyngeal and throat samples in vNAT® tubes were admitted to the laboratory for SARS Cov-2 PCR tests of 41 patients with positive PCR test results and 41 healthcare personnel who were SARS Cov-2 PCR test negative in routine institution screening. Samples Scheme 1 The tentative mechanism of the developed sensing assay for colorimetric determination of SARS-CoV-2 S-protein with TMB colorimetric reagent. a A structure of SARS-CoV-2. b Oxidation procedure of TMB (H 2 O 2 included) in the presence of magnetic γ Fe 2 O 3 nanoparticles. c Working principle of developed sensing assay were stored at 2-8°C approximately for 48 h until they were tested. All samples were run on the same day of experiment. The samples were evaluated with the naked eye according to the degree of color change in the test wells (Fig. 5B ). The scoring system (that was used to evaluate the test results) dependence to the level of color change is shown in Table 1 . Statistical power analysis was made by using the "G. Power-3.1.9.4" program. The Chi-square Goodness-of Fit Test was applied using the study rates of Ventura et al., and the standardized effect size (0.3667410) was calculated [30] . It has been calculated that a minimum of 82 people will be recruited to this study with type 1 error (alpha error) probability of 5% and 80% power at a moderate effect size and 1 degree of freedom. The importance of practical and effective assay for SARS-CoV-2 detection is undeniable nowadays. For the fabrication of our approach, first, we synthesized and characterized γ Fe2O3 magnetic nanoparticles (Fig. S1 ). Then, we formed our diagnostic assay step by step as described in the experimental part (Scheme 1). It is well known that iron oxides (γ Fe 2 O 3 and Fe 3 O 4 ) mimic the peroxidase and catalyze activity in the presence of H 2 O 2 [20, [25] [26] [27] . Herein, we prefer to use H 2 O 2 included TMB solution to simplify the procedure. γ Fe 2 O 3 acts like a peroxidase enzyme, and TMB is oxidized in the presence of H 2 O 2 (Scheme 1). In order to investigate this situation further, cyclic voltammograms for each step were monitored as presented in Fig. 1A . As it can be seen from Fig. 1A , a, TMB has two welldefined oxidation (0.41 V) and reduction peaks (0.34 V). On the other hand, for γ Fe 2 O 3 , an oxidation at 0 V and reduction peaks at more negative potential than −0.4 V are seen (Fig. 1A, b) . When these two were mixed in the presence of H 2 O 2 , the oxidation of TMB happens causing a blue color and more significant anodic and cathodic peaks (Fig. 1A, c) . ACE2 introduction to the above mixture causes a little bit decrease at the peaks (Fig. 1A, d) while after the binding of S-protein, drastic decrease especially at the oxidation peak but also at the reduction peak is observed (Fig. 1A, d) . Besides these, we examined the UV absorbance spectra of our colorimetric assay as demonstrated in Fig. 1B . Figure 1B a, belongs to the TMB spectrum with almost zero absorbance. The UV spectrum of γ Fe 2 O 3 could not be obtained due to the scatterings (not shown in the UV spectra). On the other hand, the highest absorbance was obtained for TMB (ox) corresponding to blue color at the wavelength of 654 nm when γ Fe 2 O 3 and TMB were mixed in the presence of H 2 O 2 (Fig. 1B, c) . The addition of ACE2 and S-protein separately did not change the absorbance too much (Fig. 1B , d and f) while the simultaneous addition of these two molecules in the same medium decreased the absorbance significantly (Fig. 1B, g) . Based on the previous findings in the literature, it has been known that there is a thiol−disulfide balance on the cell surface [31] . On the other hand, when the RBD part of the Sprotein binds to the ACE2 receptor, the cysteine pair of Sprotein switches between disulfide classes upon binding of the RBD to the receptor. Also, the two cysteine pairs are located parallelly and closely together and may involve in disulfide shuffling [9] . We believe that TMB here acts like an oxidoreductase molecule and causes a reduction of disulfide bonds to thiols upon binding of RBD to the receptor. In another study conducted by Xue et al., it is demonstrated that the addition of cysteine in TMB (ox) solution causes the reduction of the molecule [32] . At this point, we can not explain the exact reason for color disappearance when the binding occurs, but it might be due to the favorable alignment of cysteine molecules as mentioned above. This may also explain the reason of occurance of no color disappearance when only Sprotein or ACE2 presented in the medium. For obtaining the best results, the optimizations of reaction temperature and incubation time have been performed and given in Fig. 2 . All optimization experiments were carried out by using 1 mL of TMB, 50 μL of γ Fe 2 O 3 , 100 μL from 10 ng.mL −1 of ACE2 receptor, and 24.60 ng.mL −1 of Sprotein in the Eppendorf tubes. It is important to have a POC system that works at 25°C considering its nature. From Fig. 2a , it is clear that at 37°C, we get better results. However, at 25°C, it is still possible to see the color difference with the naked eye. For practicality, we used 25°C as our applied temperature and used this value for further studies. Meanwhile for the incubation time, apart from not being the best value, since the drastic changes occurred at 30 min and considering fast response of developed assay, we took 30 min as our optimized incubation time and used it for further studies (Fig. 2b) . Under the optimized working conditions, we examined the analytical characteristics of our assay. As can be seen from Fig. 3a , a decrease in the absorbance at the wavelength of 654 nm of blue color occurs in proportion with the increase in the concentration of S-protein. By using the decreasing absorbance values obtained due to the increase in S-protein concentration, the linear response range was determined between 4.98 ng.mL − 1 and 139.00 ng.mL −1 with an equation of y = −0.0115x + 1.8978, R 2 :0.99 (Fig. 3b) . Limit of detection (LOD) value was determined by taking the lowest concentration value in the calibration graph which is 4.98 ng.mL −1 [33] . Lastly, relative standard deviation (R.S.D) value was estimated as %3.16 ± 0.04 for 24.60 ng.mL −1 (n: 3 times). On the other hand, analytical range of the method including the UV spectrum of blank solution is given in Fig. 3c . As shown in Fig. 4A , when S-protein and influenza A viruses were mixed at the same concentrations, although a loss in the blue color was observed for S-protein (Fig. 4, d) , there was no significant color change for solutions containing influenza A viruses (Fig. 4, b and c) . This result is expected since the Influenza virus is not a virus that interacts with the ACE2 receptor. Also, this results demonstrate that our diagnostic system is capable of discriminating COVID-19 from influenza viruses. Since RT-PCR was accepted as the gold standard for this assessment, positive and negative samples by molecular techniques were accepted as true positive and true negative samples, successively (Table 2) . Overall, amongst 41 positive samples, our colorimetric assay detected 40 samples as definitive positive (Fig. 5A ). Amongst the 41 negative samples with RT-PCR test, our colorimetric biosensor detected 37 samples as definitive negative. Actually, when the results of the gold standard were compared with the colorimetric method, positive reaction was observed in 40 of 41 PCR positive patients, while the test result of one PCR positive sample was recorded as borderline. On the other hand, borderline results were observed in 2 of 41 PCR negative samples, and positive test results were found in 2 of 41 PCR negative samples with the colorimetric method. While calculating the performance properties of our test, these borderline results, that were determined with developed colorimetric biosensor, were accepted as false-negative results for the PCR-positive sample group and also were accepted as false-positive results for the PCR-negative sample group. Meanwhile, alpha variant (in the lineage B.1.1.7), a variant of SARS-CoV-2 that was first seen in Great Britain, was detected in 34 of 41 RT-PCR positive samples. As it is well known, because of huge number of mutations that are usually found in its S-protein, this variant is more transmissible compared to the other previously observed variants [34] . Overall, a similar positive reaction was seen for the results that were obtained with colorimetric biosensor independent from the presence of alpha variant. For this reason, it is obvious that the mutations that the virus has undergone over time do not have any bad influence on our colorimetric responses. Based on the parameters at Table 2 , the performance characteristics including sensitivity, accuracy, positive and negative predictive values, positive and negative likelihood ratios (LRs), and selectivity of our colorimetric biosensors were calculated and demonstrated in Table 3 . As it is well known, as LR values differ much more from the value of 1.0, the possibility of their corporation with the presence or absence of disease increases. Because of this, tests with very high LR+ and very low LR− can be very discerning, and as a result, tests with LRs >10 or < 0.1 helps us to constitute or to eliminate a diagnosis [35] . Based on the receiver operating characteristic (ROC) analysis, area under curve (AUC) has been estimated as 0.939 (p value = 0.000 < 0.05) while the confidence interval of the area under curve is found as 95%CI = [0.88, 0.99]. Overall, the ability to distinguish the test is presented by the area under the ROC curve. According to the ROC analysis results that we obtained, it can be said that the discrimination of our rapid colorimetric test method is very good. Also for real samples, the color change began at 10th min and was completed at 20th min on the contrary of 30 min that had been seen in biosensor development procedure. The need for effective, fast, and practical detection of SARS-CoV-2 is very important nowadays. Herein, we manage to develop a practical approach for SARS-CoV-2 diagnosis. The ease and practicality of the method make it an important candidate for becoming an effective diagnostic kits for SARS-CoV-2 detection in future. On the other hand, considering the mutations that happen until now, our detection assay will be beneficial because there is no need to change antigens or any other reagents like primer reagents, etc. The application of developed colorimetric assay to the real samples resulted with very good agreement with PCR method. Also, the successful detection of alpha variant of COVID-19 demonstrated that our assay is capable to detect the variants because of its interaction mechanism. Considering the performance characteristics of the developed colorimetric assay, it can be concluded that the system is a serious candidate to be a rapid screening test in the diagnosis of suspected cases of COVID-19. Author contribution Yudum Tepeli Büyüksünetçi and Ülkü Anık "contributed" to the development and optimization of colorimetric biosensor together with analytical characteristics examinations. They are also involved at the real sample analysis with newly developed biosensor. Burak Ekrem Çitil and Utku Tapan were responsible from the real sample collections and analysis of them with the newly developed biosensor system and PCR methods. Funding This work was supported by BAP Project department of Mugla Sıtkı Kocman University with the project number of 20/108/02/1/4. Also for this study, the patent application has been made with the application number of 21/00352. Nanobiosensors as new diagnostic tools for SARS, MERS and COVID-19: from past to perspectives A nanoscale genosensor for early detection of COVID-19 by voltammetric determination of RNA-dependent RNA polymerase (RdRP) sequence of SARS-CoV-2 virus Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2): an overview of viral structure and host response Voltammetricbased immunosensor for the detection of SARS-CoV-2 nucleocapsid antigen The origin, transmission and clinical therapies on coronavirus disease 2019 (COVID-19) outbreak-a n update on the status Coronaviruses: an overview of their replication and pathogenesis Structure, function, and antigenicity of the SARS-CoV-2 spike glycoprotein Cryo-EM structure of the SARS coronavirus spike glycoprotein in complex with its host cell receptor ACE2 Structural basis of SARS-CoV-2 spike protein induced by ACE2 Tissue distribution of ACE2 protein, the functional receptor for SARS coronavirus. A first step in understanding SARS pathogenesis A novel angiotensin-converting enzyme-related carboxypeptidase (ACE2) converts angiotensin I to angiotensin 1-9 An electrochemical immunosensor for the corona virus associated with the Middle East respiratory syndrome using an array of gold nanoparticle-modified carbon electrodes Electrochemical immunosensor with Cu2O nanocube coating for detection of SARS-CoV-2 spike protein Differential diagnosis of illness in patients under investigation for the novel coronavirus (SARS-CoV-2) Improved molecular diagnosis of COVID-19 by the novel, highly sensitive and specific COVID-19-RdRp/Hel real-time reverse transcription-PCR assay validated in vitro and with clinical specimens Presymptomatic Transmission of SARS-CoV-2 -Singapore Development of a SARS-CoV-2-specific biosensor for antigen detection using scFv-Fc fusion proteins Low performance of rapid antigen detection test as frontline testing for COVID-19 diagnosis An overview on enzyme-mimicking nanomaterials for use in electrochemical and optical assays The CoOOH-TMB oxidative system for use in colorimetric and test strip based determination of ascorbic acid 2020) β-Cyclodextrin coated porous Pd@Au nanostructures with enhanced peroxidase-like activity for colorimetric and paper-based determination of glucose Detection of CEA in human serum using surface-enhanced Raman spectroscopy coupled with antibody-modified Au and γ-Fe2O3@Au nanoparticles Development of a sandwich immunosensor for concurrent detection of carcinoembryonic antigen (CEA), vascular endothelial growth factor (VEGF) and Α-fetoprotein (AFP) biomarkers Colorimetric estimation of human glucose level using γ-Fe 2O3 nanoparticles: an easily recoverable effective mimic peroxidase Soft template induced phase selective synthesis of Fe2O3 nanomagnets: one step towards peroxidase-mimic activity allowing colorimetric sensing of thioglycolic acid Colorimetric quantification and discrimination of phenolic pollutants based on peroxidaselike Fe3O4 nanoparticles The involvement of CD146 and its novel ligand galectin-1 in apoptotic regulation of endothelial cells Enhanced colorimetric signal for accurate signal detection in paper-based biosensors Colorimetric test for fast detection of SARS-COV-2 in nasal and throat swabs Impact of thiol-disulfide balance on the binding of COVID-19 spike protein with angiotensinconverting enzyme 2 receptor A naked-eye liquidphase colorimetric assay of simultaneous detect cysteine and lysine Highly sensitive and specific colorimetric detection of cancer cells via dual-aptamer target binding strategy SARS-CoV-2 Variant Classifications and Definitions Understanding the properties of diagnostic tests -Part 2: Likelihood ratios Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations Conflict of interest The authors declare no competing interests.