key: cord-0936480-zufurgi1 authors: Pan, Chun; Chen, Lu; Lu, Cong; Du, Bin; Brochard, Laurent; Qiu, Haibo title: Reply by Pan et al. to Haouzi et al. date: 2020-08-15 journal: Am J Respir Crit Care Med DOI: 10.1164/rccm.202005-2045le sha: 99e9f49420a997de18bc9e4708ba3708dbd4e567 doc_id: 936480 cord_uid: zufurgi1 nan Reply by Pan et al. to Haouzi et al. We appreciate Dr. Haouzi and his colleagues for their interest in our research letter (1) . They reanalyzed our reported data and found a possible but nonsignificant coupling between lower compliance and greater alveolar PO 2 (PA O 2 )-Pa O 2 gradient. They then suggested that positive end-expiratory pressure (PEEP) should be titrated by reaching the highest compliance and lowest PA O 2 -Pa O 2 gradient. We want to point out that a possible association between compliance and PA O 2 -Pa O 2 gradient among different patients makes physiological sense but may not be applied for PEEP titration in a given individual; the PEEP providing the highest compliance can be completely different from the PEEP providing the lowest PA O 2 -Pa O 2 gradient. Actually, we have observed that patients with coronavirus disease (COVID-19)-associated acute respiratory distress syndrome (ARDS) from Wuhan often present "better" compliance and "worse" PA O 2 -Pa O 2 gradient at low PEEP. We thus will discuss the optimal compliance and the optimal PA O 2 -Pa O 2 gradient as two respective PEEP strategies. Titrating PEEP by the optimal compliance has been proposed for several decades, but years of research have shown many pitfalls and limitations. 1) Plateau pressure can be measured by performing varied durations of end-inspiratory occlusion, and the pressure value can change according to viscoelastic properties, pendelluft, or simply the presence of leaks. This technical issue is not trivial. A preset 0.2-to 0.3-second end-inspiratory pause minimizes this issue, providing more reliable plateau pressure as an indicator of the maximal lung distension (2). 2) Some physiological studies using electrical-impedance tomography suggested that a high PEEP guided by "best" compliance of the whole respiratory system can be substantially higher than the PEEP based on regional compliance or on the dorsal fraction of ventilation reaching 50% and that the chest wall could play a role in these discrepancies (3) . 3) In contrast, when substantial tidal recruitment is present at low PEEP, compliance may be increased by this tidal recruitment (4). Using this "best" compliance would therefore favor ongoing repeated recruitment and collapse. 4) The optimal compliance approach has been tested in a large randomized controlled trial, showing no benefit on outcome (5) . The PA O 2 -Pa O 2 gradient can be a useful physiological indicator during clinical practice, but we cannot rely on it for PEEP titration because of the following considerations. PA O 2 -Pa O 2 gradient by using a simplified alveolar gas equation assumes that the respiratory quotient is 0.8 in all patients. This might not be the case in our critically ill patient with ARDS. Particularly, three patients in our study (1) received extracorporeal membrane oxygenation, an intervention that can remarkably alter the respiratory quotient. 2) For a given FI O 2 , titrating PEEP by reaching the lowest PA O 2 -Pa O 2 gradient is similar to seeking the "best" oxygenation but can be misled by an increase in Pa CO 2 . In other words, both an increase in the Pa CO2 and an increase in Pa O 2 can reduce the calculated PA O 2 -Pa O 2 gradient. 3) Although it may be practically preferable to assume the PA O 2 -Pa O 2 gradient represents the shunt in patients with ARDS, optimizing PEEP by reaching the lowest shunt can be misdirected by a reduction in cardiac output. Indeed, classical studies have shown that higher PEEP often reduces cardiac output and then reduces the intrapulmonary shunt (6) . Improved Pa O 2 and PA O 2 -Pa O 2 gradient can then be observed with higher PEEP, but the price may be a lower oxygen delivery to the tissues because of the reduction in cardiac output. For these multiple reasons, we prefer to rely on the direct assessment of lung recruitability to guide the PEEP setting. Our primary goal is to reduce the risk of ventilator-induced lung injury, such as atelectrauma and overdistension. Our study has demonstrated that the assessment of lung recruitability is feasible at the bedside by only using the ventilator of the patient, even in very constrained situations like COVID-19 (1). n Author disclosures are available with the text of this letter at www.atsjournals.org. Lung recruitability in COVID-19-associated acute respiratory distress syndrome: a single-center observational study Fifty years of research in ARDS: respiratory mechanics in acute respiratory distress syndrome Regional ventilation displayed by electrical impedance tomography as an incentive to decrease positive end-expiratory pressure Potential for lung recruitment estimated by the recruitment-to-inflation ratio in acute respiratory distress syndrome: a clinical trial Effect of lung recruitment and titrated positive end-expiratory pressure (PEEP) vs low PEEP on mortality in patients with acute respiratory distress syndrome: a randomized clinical trial Depression of cardiac output is a mechanism of shunt reduction in the therapy of acute respiratory failure Reply by Xu et al. to Haouzi et al. Globally, numerous patients with coronavirus disease (COVID-19) develop acute respiratory distress syndrome (ARDS) and require mechanical ventilation (1) (2) (3) . Great attention is paid to the respiratory pathophysiology of COVID-19, which potentially leads to "atypical" ARDS (4). A recent study by Haouzi and colleagues reanalyzed the data from a newly published case series reporting the lung mechanics of COVID-19 (4-6) and found enormous heterogeneity of COVID-19-related ARDS. In our previous study, hypercapnia was common when using low VT ventilation in such patients with ARDS (5). Elevated pulmonary dead space in these patients was captured by ventilatory ratio and reinforced by Haouzi and colleagues. Reports have indicated that increased dead space is independently associated with an increased risk of death in patients