key: cord-0936414-hriay9ce authors: Pechlivanis, N.; Tsagiopoulou, M.; Maniou, M. C.; Tougkousidis, A.; Laidou, S.; Vlachonikola, E.; Mouchtaropoulou, E.; Chassalevris, T.; Chaintoutis, S.; Dovas, C.; Petala, M.; Kostoglou, M.; Karapantsios, T.; Chatzidimitriou, A.; Papadopoulos, A.; Papaioannou, N.; Argiriou, A.; Psomopoulos, F. title: Detecting SARS-CoV-2 lineages and mutational load in municipal wastewater; a use-case in the metropolitan area of Thessaloniki, Greece date: 2021-03-20 journal: nan DOI: 10.1101/2021.03.17.21252673 sha: 28ef588af70952b3fafc5a8262208f2cea03c867 doc_id: 936414 cord_uid: hriay9ce The SARS-CoV-2 pandemic represents an unprecedented global crisis necessitating novel approaches for, amongst others, early detection of emerging variants relating to the evolution and spread of the virus. Recently, the detection of SARS-CoV-2 RNA in wastewater has emerged as a useful tool to monitor the prevalence of the virus in the community. Here, we propose a novel methodology, called lineagespot, for the detection of SARS-CoV-2 lineages in wastewater samples using next-generation sequencing. Our proposed method was tested and evaluated using NGS data produced by the sequencing of three wastewater samples from the municipality of Thessaloniki, Greece, covering three distinct time periods. The results showed a clear identification of trends in the presence of SARS-CoV-2 mutations in sewage data, and allowed for a robust inference between the variants evident through our approach and the variants observed in patients from the same area time periods. Lineagespot is an open-source tool, implemented in R, and is freely available on GitHub (https://github.com/BiodataAnalysisGroup/lineagespot) Nearly a year after the first report of SARS-CoV-2 in Wuhan, China, the virus has spread at an unprecedented pace causing a global pandemic. As the main transmission process of the SARS-CoV-2 virus is through droplets and the contact between people, several testing strategies identify whether a person is infected and, in cases of a positive sample, what is the underlying virus variant. However, these methods are not easily scalable, especially in large urban areas. Interestingly, the viral RNA can also be detected in wastewater, with SARS-CoV-2 RNA levels in wastewater correlating with the COVID-19 epidemiology [1] [2] [3] . Indeed, in the previous work of Petala et al 3 . normalized viral copy levels P a g e 3 | 14 excluding all rules based on the unmutated reference (Total Overlap Var) . In addition to the previous metrics, the related ratio values are also calculated (Tree ratio, Total Ratio, Total Ratio Var). Finally, information regarding the read depth for each position (reference and variant) is also provided in the output file. Based on this detailed table, a second output is generated as a simplified summary. In this case, all rows for which the Total Overlap Var column was equal to 0 were removed, and therefore potential lineages that would be assigned based only on the unmutated reference (i.e. no actual mutations detected) are excluded from the analysis. The remaining rows were collapsed ( Table 2 ) through a process in which the average values of the basic metrics were calculated for each lineage; i.e. the mean of the Tree Ratio, the Total Ratio, the Total Ratio Var, the Tree Av AD, the Total Av AD, and the Avg AF columns. Depending on the variant caller tool used (freebayes, mpileup and GATK Mutect2), lineagespot generates a unique output. All outputs are compared pairwise, based on the decision tree rules ( ), and the total number of rules satisfied ( ). For each lineage, the absolute values of the differences between the two metrics ( , ) of the files are calculated. As an example, for lineage A.1, the output produced by using the freebayes variant caller tool in the first step of the methodology, returns = 2 and = 10 rules satisfied, while the output of the GATK Mutect2 tool returns = 1 and = 4 rules satisfied. As a result, the two outputs exhibit a difference of = 1 and = 6 rules ( Table 3 ). In addition, the total number of lineages are shown in Table 4 . In the same table, the maximum absolute difference and the maximum difference for each pair of files are calculated. The latter is used for an overall comparison of the output files. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint Based on the above comparison, we consider that the most productive and informative approach is to utilize freebayes as the variant calling tool. The rest of the results shown below, are based only on the freebayes tool output. The proposed methodology was applied on three sewage samples, across three time periods: 02-14/12/2020 (SampleA), 05-11/02/2021 (SampleB) and 12-18/02/2021 (SampleC). . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted March 20, 2021. ; https://doi.org/10.1101/2021.03.17.21252673 doi: medRxiv preprint P a g e 5 | 14 is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted March 20, 2021. ; https://doi.org/10.1101/2021.03.17.21252673 doi: medRxiv preprint P a g e 6 | 14 is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint Qualitative assessment between the major lineages found in the biased sampling and the three time periods. Analyzing wastewater -used water that goes through the drainage system to a treatment facilityis a way that researchers and surveillance systems can track pathogens that are excreted in urine or feces, such as SARS-CoV-2. Monitoring effluents could provide better estimates on coronavirus spread . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted March 20, 2021. ; https://doi.org/10.1101/2021.03.17.21252673 doi: medRxiv preprint P a g e 9 | 14 than sampling and testing the population, because wastewater surveillance can account for those who have not been tested and have only mild or no symptoms. Moreover, an effective and reliable methodology able to detect virus load and SARS-CoV2 variants from municipal wastewater samples could drastically, or at least help, decrease the cost of virus variant detection in the general population based on whole genome sequencing. In this manuscript we present and validate a methodology named lineagespot, making use of Next Generation Sequencing data, able to detect lineages and mutational load of SARS-CoV2. The methodology aims to aid the epidemiological system for the monitoring of COVID 19 pandemic in urban areas. The method has been tested in different time point samples taken from the main Municipal Wastewater Treatment Plant of Thessaloniki -Greece, where effluents from approx. 750.000 inhabitants are collected. The lineagespot method demonstrated to be sensitive enough to identify and quantify differences in the mutational load, across various time points. Moreover, the quantitative data obtained using lineagespot are in accordance with the trends of well-known mutations (such as Asp614Gly) in the same period with the overall epidemiological status of the municipal area. The application of lineagespot in such complex samples, like those from Wastewater Treatment Plants, was able to assign lineages and in agreement with the trend of the major lineages detected in the area of Thessaloniki, in the three time points by whole genome sequencing of samples from the general population. Overall, the method compared to other ones (Sanger sequencing) 4,7 resulted more informative, sensitive enough to detect mutations with low frequency and able to assign with good approximation the correct lineage present in the municipality. Wastewater samples were collected from the entrance of the main Municipal Wastewater Treatment Plant of the city which accommodates sewerage of about 750.000 inhabitants. Wastewater entering this Plant refers exclusively to citizens from urban districts of the city. Typical values of certain physicochemical properties of wastewater samples tested in this study are displayed in Table 1 . These properties demonstrate, among others, the existence of suspended solids, dissolved organic matter, dissolved oxygen and salinity that may have strong impact on viral adsorption and decay because of oxidation and increased metabolic activity of microorganisms in sewage. The residence time of sewage until the entrance of the Plant is between 2 and 7 hours (depending on the area), which is more than enough to allow viral adsorption and decay. Identification of mutations may be hindered by viral adsorption and decay and for this reason the present effort is particularly significant. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The targeted sequencing method was applied by preparing 400nt amplicons using the ARTIC v3 protocol developed by Wellcome Sanger Institute 9 , with some modifications. First, cDNA synthesis was prepared from 10 ul of RNA using SuperScript II reverse transcriptase (Invitrogen -Thermo Fisher Scientific, USA) and 50 ng/ul of random primers according to the protocol guidelines. For subsequent cDNA amplification, 2.5 ul of the generated cDNA was used instead of 6 ul, using ARTIC PCR primer pools (v3). Finally, the NEBNext adaptor (New England Biolabs, US, #7335) was used in the ligation reaction, diluted with adaptor dilution buffer at 10μΜ final concentration. All purification steps were . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The initial phase of the bioinformatics analysis is to produce an alignment of the sequencing reads, while maintaining extremely strict criteria, in order to remove any potential contaminants and/or sequencing errors. The first step is the adaptor removal process, where any adaptors are removed from the raw fastq sequences, with the cleaned reads mapped to the SARS-CoV-2 reference genome (Wuhan variant, NC_045512), using minimap2 tool 10 with a minimal chaining score (matching bases minus log gap penalty) equal to 40. From this process, only the paired-end sequences are retained, while any other (unmatched, multiple mappings, etc.) are removed. In the next step, the primer sequences are excluded using the ivar tool 11 , setting a minimum of 200 length in nucleotides for a read to be retained after trimming, and a minimum threshold for sliding window of 15 quality to pass (width of sliding window equal to 4). The final sequences are then remapped to the same reference genome (minimal chaining score equal to 40). Finally, and in order to be able to detect low frequency variants, the freebayes variant caller was used with a low variant frequency parameter of 0.01. Ultimately, all identified mutations were annotated using the SnpEff tool 12 and the NC_045512.2 (version 5.0) database. In order to identify and assign different SARS-CoV-2 lineages based on the mutations detected from a single sewage sample, we implemented the proposed methodology in a tool named lineagespot. The tool accepts as input a VCF file, which contains all mutations identified in the sample, along with the reference SARS-CoV-2 genome file, and a file containing all lineage-assignment rules, as retrieved from the pangolin tool 13 repository. After analyzing all inputs, a tab-delimited file (TSV file) is produced containing the most probable lineages that have been found. Figure 1 shows an overview of the tool's functionalities, which can be described in 2 phases: Creating rules from variants In this phase all rules that can be derived from the VCF file are constructed. Initially, a vector of all genome positions is created, for which each position is set to be equal to the reference genome nucleotides. Then, the VCF file is read and a set of new rules is formed by setting each position of the file with the reported variant or multiple variants (in case there is more than one reported variant at the same position). It should be noted that positions that have been detected with more than one variant, should include all of them at the VCF's ALT column in a comma-delimited format. Most of the variant caller tools (freebayes, GATK, etc.) are doing this by default. Finally, positions with reference read depth equal to zero are removed from the first vector. The remaining two vectors are merged into one. In addition to finding all positions that need to be set equal to the base that has been allocated, four more rules are added for each genome position. These rules contain all bases not equal to the nucleotide of the original rule. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint Comparing with pangolin rules The second phase aims to compare the rules derived from the VCF file with the assignment rules provided by the pangolin tool. Specifically, all decision rules are read from the input pangolin file, and for each lineage, the related rules are compared with the final rule vector. Three metrics are computed and stored in the output file; the total number of rules leading to the related lineage ( ), the number of rules satisfied by the created rule vector, considering pangolin's rules as a decision tree ( ), and the total number of rules satisfied ( ). Also, the related ratio values are being computed, giving a satisfaction percentage of each lineage: It should be noted that the methodology relies on the following assumption. Given a group of reads that satisfy a rule A of lineage L, and another group of reads that satisfy rule B from the same lineage L, then the lineage L is incorrectly assigned. As an example, suppose that a group of reads satisfy only the first two rules from lineage B. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted March 20, 2021. ; https://doi.org/10.1101/2021.03.17.21252673 doi: medRxiv preprint P a g e 13 | 14 above, lineage B.1.177.17 will be marked as an identified lineage, even though none of the reads satisfy all the rules of the lineage. In order to mitigate this risk, we are taking into consideration a number of different indicators, that reflect the number of total rules satisfied, the number of rules that are satisfied based on the detected mutations, and the overall number of reads that support both reference and allele for each of the rules. Secretariat for Research and Innovation, under the Public Investments Program (PIP). Additionally, this work was supported by ELIXIR, the research infrastructure for life-science data. NP, MT, MCM and AT developed the lineagespot code and performed the downstream analysis. NP and MT performed the analysis of the raw NGS data. EM, SL and EV did the library preparation. CD and AC provided the data and reviewed the submitted version. MP and MK participated in experimental investigation. AP, NP, and TK participated in project conceptualization, management and funding. FP and AA designed, supervised the study, and reviewed the manuscript. All authors contributed to the article and approved the submitted version. The implemented code that produces the results of this paper, starting from the VCF files, is available on the GitHub repository: https://github.com/BiodataAnalysisGroup/lineagespot. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint Temporal detection and phylogenetic assessment of SARS-CoV-2 in municipal wastewater Detection of SARS-CoV-2 variants in Switzerland by genomic analysis of wastewater samples A physicochemical model for rationalizing SARS-CoV-2 concentration in sewage. Case study: The city of Thessaloniki in Greece Tracking SARS-CoV-2 in Sewage: Evidence of Changes in Virus Variant Predominance during COVID-19 Pandemic Genome Sequencing of Sewage Detects Regionally Prevalent SARS-CoV-2 Variants Monitoring SARS-CoV-2 circulation and diversity through community wastewater sequencing Wastewater surveillance for population-wide Covid-19: The present and future First confirmed detection of SARS-CoV-2 in untreated wastewater in Australia: A proof of concept for the wastewater surveillance of COVID-19 in the community COVID-19 ARTIC v3 Illumina library construction and sequencing protocol v4 (protocols.io.bgxjjxkn) Minimap2: pairwise alignment for nucleotide sequences An amplicon-based sequencing framework for accurately measuring intrahost virus diversity using PrimalSeq and iVar Using Drosophila melanogaster as a Model for Genotoxic Chemical Mutational Studies with a New Program This work was supported by the "Greece vs Corona: Flagship Action to address the SARS-CoV-2 crisis. Epidemiological study in Greece through extensive testing for virus and antibody detection, viral genome sequencing and genetic analysis of patients" project, which is funded by the General