key: cord-0934725-ukquibxm authors: Fidler, Aleš; Steyer, Andrej; Manevski, Damjan; Gašperšič, Rok title: Virus transmission by ultrasonic scaler and its prevention by antiviral agent: an in vitro study date: 2021-11-03 journal: J Periodontol DOI: 10.1002/jper.21-0335 sha: 606e6109c5be59c16b1deca5d042044bc93526d6 doc_id: 934725 cord_uid: ukquibxm BACKGROUND: It is well recognized that dental procedures represent a potential way of infection transmission. With the COVID‐19 pandemic, the focus of dental procedure associated transmission has rapidly changed from bacteria to viruses. The aim was to develop an experimental setup for testing the spread of viruses by ultrasonic scaler (USS) generated dental spray and evaluate its mitigation by antiviral coolants. METHODS: In a virus transmission tunnel, the dental spray was generated by USS with saline coolant and suspension of Equine Arteritis Virus (EAV) delivered to the USS tip. Virus transmission by settled droplets was evaluated with adherent RK13 cell lines culture monolayer. The suspended droplets were collected by a cyclone aero‐sampler. Antiviral activity of 0.25% NaOCl and electrolyzed oxidizing water (EOW) was tested using a suspension test. Antiviral agents' transmission prevention ability was evaluated by using them as a coolant. RESULTS: In the suspension test with 0.25% NaOCl or EOW, the TCID50/ml was below the detection limit after 5s. With saline coolant, the EAV‐induced cytopathic effect on RK13 cells was found up to the distance of 45 cm, with the number of infected cells decreasing with distance. By aero‐sampler, viral particles were detected in concentration ≤4.2 TCID50/ml. With both antiviral agents used as coolants, no EAV‐associated RK‐13 cell infection was found. CONCLUSION: We managed to predictably demonstrate EAV spread by droplets due to USS action. More importantly, we managed to mitigate the spread by a simple substitution of the USS coolant with NaOCl or EOW. This article is protected by copyright. All rights reserved It is well recognized that dental procedures represent a potential way of infection transmission by using air-water syringes, ultrasonic scalers (USS), high-speed handpieces, and lasers due to extensive generation of droplets and aerosol. 1,2 A concern was recently raised in medical literature, pointing to confusion in definition of aerosol and droplets, based on particle size threshold. 3, 4 Interestingly, similar viewpoint on composition and terminology was raised in dental literature and the term "dental spray" was proposed for spatter, droplets, droplet-nuclei and a true aerosol, created by saliva and water coolant combined with high-speed instrumentation. 5 This article is protected by copyright. All rights reserved. 3 /19 In the past, the spread of bacteria associated with dental procedures has already been extensively studied in real or artificial working environment settings, reporting on large contamination to operator's face and head, patient chest and also surfaces up to 3 meters from the patients' mouth. 1 To reduce bacterial load, preprocedural mouth-rinse was suggested despite the moderate level of evidence to support such action. 6 The bacterial content of aerosols was reduced 2 to 7 fold by using povidoneiodine and chlorhexidine gluconate as an ultrasonic coolant compared with water in an in-vivo study. 7 Although the SARS-CoV outbreak in 2004 was recognized in dental literature 8, 9 , until recently 10 , no direct research data were available on virus transmissions associated with dental procedures. 11 With the COVID-19 pandemic, the focus of dental procedure associated transmission has rapidly changed from bacteria to viruses. It is generally acknowledged that dental procedures represent a high risk of SARS-CoV-2 virus transmission [12] [13] [14] [15] due to its presence in saliva 16 , gingival crevicular fluid 17 , nasopharyngeal, oropharyngeal and bronchial excretions. 18 In addition to the respiratory droplets and contact routes 19 , SARS-CoV-2 virus may be transmitted by the dental spray that is generated from a mixture composed of virus-containing oral fluids and water from the dental unit water system. For the provision of safe dental care for dental team members and patients, numerous preventive measures were proposed and included in professional [12] [13] [14] [15] and national 20 guidelines. These range from pre-procedure mouth-rinse, use of personal protective equipment, high volume evacuation, air purification (ventilation, filtering, air disinfection), and surface disinfection. Personal protective equipment can protect the dental care providers; however, the contamination of clinical environments by sprays still necessitates periods of "fallow time" between appointments to protect patients and staff. 21 A special concern was raised for open plan clinic environments, reporting a safe distance of 5 m. 22 Although preprocedural mouth-rinse is included in most recommendations 20 , its effectiveness is questionable as no scientific clinical evidence exists for reducing the viral load. 23 So far, antiseptic mouth rinses containing cetylpyridinium chloride or povidone-iodine have shown the highest potential to reduce viral load in infected subjects. 24 Thus, there is a high need for effective prevention measures against virus transmission in dentistry. 25 This article is protected by copyright. All rights reserved. Although a simple replacement of cooling liquid with a virucidal agent might potentially reduce viral spread, this possibility was only recently evaluated by 0.5% hydrogen peroxide cooling spray used in air-turbine, demonstrating reduction of viral RNA below detection threshold on all tested sites. 10 Besides hydrogen peroxide, several agents were already found to be effective against coronaviruses in as short as 30 s of suspension test. 26 Some of them, like sodium hypochlorite (NaOCl) 27 have already been evaluated for safe use as a daily oral rinse. Additionally, the electrolyzed oxidizing water (EOW) was proposed as an effective and safe biocidal agent for nasal 28 or ocular 29 application. The aim of the study was twofold, (i) to develop an experimental model for evaluation of infective virus transmission by USS activity, and (ii) to evaluate the reduction of USS viral transmission by replacement of cooling water with a virucidal agent pretested for antiviral activity in suspension test. To evaluate our hypothesis, we have designed a virus transmission tunnel (VTT), thus simulating dental spray generating dental procedure in a controlled laboratory environment. It featured the operating USS in the presence of virus suspension and virus sampling device for a spill, settled droplets, and suspended droplets. It (1.73ml/min) through a pre-curved, 20G blunt, rounded tip needle (0.9 x 42 mm) (Transcodent, Kiel, Germany), stably mounted with a connecting element (Fig. 1) . For experiments, a laboratory Equine Arteritis Virus (EAV) strain was used. EAV was This article is protected by copyright. All rights reserved. 6/19 The virus was efficiently propagated in an adherent RK13 cell line (source: Oryctolagus cuniculus, kidney, epithelial). Eagle's Minimum Essential Medium (Sigma-Aldrich, MO) was used for cell culture medium, supplemented with final 10% fetal bovine serum (EuroClone, Italy) concentration. Virus concentration in LIQ and SUSP_D was determined with titration on cell monolayer in 96-well microtiter plate. Each 10-fold dilution was inoculated in 8 replicates, including negative control. Briefly, cell culture media was removed from the cell monolayer, and 100 µl of virus suspension (LIQ or SUSP_D sample) was added to each well. The inoculated microtiter plate was incubated for up to 4 days in 37°C, 5% CO 2 atmosphere, and 95% humidity. After four days, cells were screened for CPE, and the number of infected wells was recorded. Virus transmission in SET_D was evaluated by CPE formation in exposed microliter plates incubated for up to 4 days in 37°C, 5% CO 2 atmosphere, and 95% humidity. The virucidal ability of two coolants was evaluated with a suspension test. A 0.25% NaOCl and EOW ( exposed to the agent, and a reduction of infective virus particles was evaluated after a contact time of 5s, 30s, 1 min, 5 min, and 10 min. The virus transmission prevention test was evaluated with the same experimental setup as for the virus transmission test, except that the sterile saline (as a cooling agent) was replaced by agents evaluated in suspension tests: 0.25% NaOCl in the first and EOW in the second experiment. The coolant flow rate was the same as in the virus transmission test. For each coolant, the experiment was repeated twice. A 5% significance level was taken for the statistical analysis. The t-test was used for The suspension test results are shown in Table 2 . For saline, the virus concentration was measured at time 0 and after 600s. No reduction in the viral concentration was observed for saline after 600s contact time and the difference (at 0 and 600s) was not statistically significant (p=0.76). On the other hand, both antiviral agents (0.25% NaOCl and EOW) effectively reduced the virus concentration already after 5s to a concentration below the detection limit (< 2.8 log10 (conc)/TCID50/ml). Even though the exact values after 5s were not known, a t-test for the worst scenario (2.8 log10 (conc)/TCID50/ml) yielded a statistically significant decrease (p=0.003) of viral concentration for both 0.25% NaOCl and EOW. Thus, both antiviral agents significantly decreased the viral concentration from 5s onwards compared to the initial viral concentration (Table 2 ). This article is protected by copyright. All rights reserved. 8/19 The estimated viral concentration in the saline generated LIQ sample, collected in the vicinity of the droplet-generating platform, was 3.25 log TCID 50 /ml. In LIQ of both virucidal agents, no infective viral particles were detected. Importantly, a cytotoxic effect of NaOCl was found in LIQ for dilutions up to 10 5 , while no cytotoxic effect was found for EOW. In DSs collected in wells, CPE associated with viral infection was found up to the distance of the first 16 of 18 lines of cultivation plates. In SET_D sampled with 0.25% NaOCl used as a coolant (Figure 2 ), a cytotoxic effect was found in the first six lines, and thus the effect of infective viruses (CPE) could not be evaluated. In lines from 6 to 18, no CPE nor cytotoxic effect was found. With EOW as a coolant (Figure 2 ), nor CPE neither cytotoxic effect was found in any distance. Although it is apparent (from Figure 2) In one SUSP_D only, viral particles were detected in a very low concentration, which was ≤0.63 log TCID 50 /ml. In SUSP_D, for both antiviral coolant experiments, no infective viral particles were detected. However, for 0.25% NaOCl cytotoxic effect was found at 10 -1 dilution. Virus specific real-time RT-PCR to test selected cell culture wells with clearly visible CPE revealed a strong positive result with a ct value between 13.00 and 15.00. In contrast, all tested wells without visible CPE and unaffected cell monolayer were negative with real-time PCR, which confirmed the absence of virus propagation and the viral RNA load below the limit of detection. The study results indicate that by USS activity EAV was transmitted mainly by settled droplets and up to the distance of 45 cm. The transmission of EAV by suspended droplets, however, yielded inconclusive results. More importantly, the virus droplet transmission was prevented by replacing saline with a virucidal agent that has already been tested as mouth-rinse for home oral care. For our experiments, a non-human viral pathogen was selected, which is similar (by structure and genome) to SARS-CoV-2. An Equine Arteritis Virus (EAV) is an animal pathogen, which is species-restricted to Equidae members. EAV is an enveloped virus with a single-stranded, positive-sense RNA genome. EAV is also a member of Baltimore's IV group and presents a similar structure to Coronaviruses, similar stability in the environment, and inactivation by general disinfectant as SARS-CoV-2. 31, 32 Besides, EAV is also transmitted through respiratory route and aerosol transmission, although indirect or close contact is mandatory for infection. 31 In the first part of the study, we designed an experimental setup to demonstrate the considerably longer than in our experiment and represent a higher cumulative viral load and increase probability of infection. 34 Another reason could be the low percentage of viral particles in suspended droplets. As the volume of a typical suspended droplet particle with a diameter of 1µm is 5.23x10 -13 ml, and 3.58x10 11 of such particles may be generated from 1 ml, it is possible to calculate a fraction of particles actually harboring a virus (4.97x10 -9 ) by dividing the number of virus particles in 1 ml by the number of suspended droplets (1.78x10 3 / 3,58x10 11 ). However, to support such calculation, better characterization of dental spray particles would be needed. This article is protected by copyright. All rights reserved. 11 /19 In our experiments, the clear virus suspension with a concentration of log 4.12±0.60 TCID 50 /ml and flow of 1.73 ml/min was diluted with coolant with flow between 12.5 and 17.5 ml/min. The concentration of log 3.25±0.59 TCID 50 /ml was measured in LIQ. This observation is in accordance with a recent paper, stating that dilution due to mixing of the introduced coolant with real saliva also requires consideration. 21 In our case, with virus titration control in saline suspension and splatter collected directly at the USS, the concentration reduction was 0.87 log, which is near 10x dilution and goes perfectly with the ratio of virus suspension and coolant flow. This observation confirms the importance of dilution, as noted in previous studies. 22, 37 In the second part of the experiment, we managed to prevent the droplet spread of test failed to prove virucidal capacity of 1% H 2 O 2 (data not shown), which was even higher than the concentration that reduced coronavirus RNA spread by air-turbine. 10 As no suspension testing was reported and only reduced RNA levels were measured, successful transmission of infective virus by air-turbine as well its mitigation 10 may be questioned from different methodological aspects. This article is protected by copyright. All rights reserved. A low level of cytotoxicity and the high virucidal effect of EOW are optimal for highly effective potential disinfectants in dental procedures. EOW was found to have no systemic effects when it was provided to mice as water during a two-week experiment, which served to the authors as indirect proof for safe usage as a mouthwash. 36 EOW was already proposed as an effective and safe biocidal agent for nasal 28 or ocular 29 application. Similarly, the 0.25% NaOCl has been proposed for oral rinse. 39, 40 Since SUSP_D from the NaOCl experiment exhibited cytotoxic effect already at 10 -1 dilution, we could assume that NaOCl-containing suspended droplets dental instruments 21 , the generalization of our findings into the wide variety of clinical settings is difficult due to variability of USS devices and their operating parameters, including power setting tip selection and coolant flow rate. Even larger differences may be found between dental procedures. 44 Another limitation of this study a lack of quantitative characterization of dental spray particles and such evaluation would be necessary in the further research. 5, 45 In conclusion, by using the proposed experimental model, we managed to predictably demonstrate infective virus spread by droplets due to USS action. More importantly, we managed to mitigate the virus spread by a simple substitution of the coolant with clinically tested virucidal agents, namely sodium hypochlorite or EOW. Future research using the proposed experimental model should include other dental spray generating dental procedures, additional agents, and ultimately the SARS-CoV-19 virus before clinical application. Nevertheless, the proposed principles for virus spread mitigation seems promising and warrant further evaluation. A systematic review of droplet and aerosol generation in dentistry Centers for Disease Control and Prevention. Interim Infection Prevention and Control Guidance for Dental Settings During the Coronavirus Disease 2019 (COVID-19) Pandemic. Available at How Did We Get Here: What Are Droplets and Aerosols and How Far Do They Go? A Historical Perspective on the Transmission of Respiratory Infectious Diseases Airborne or droplet -is ti possible to say? Demystifying the mist: Sources of microbial bioload in dental aerosols Efficacy of preprocedural mouthrinses in the reduction of microorganisms in aerosol: A systematic review Comparative Evaluation of Two Different Ultrasonic Liquid Coolants on Dental Aerosols Severe Acute Respiratory Syndrome (SARS) and the GDP. Part I: Epidemiology, virology, pathology and general health issues Severe Acute Respiratory Syndrome (SARS) and the GDP. Part II: Implications for GDPs Aerosols modification with H2O2 reduces airborne contamination by dental handpieces Interventions to Reduce Aerosolized Microbes in Dental Practice: A Systematic Review with Network Meta-analysis of Randomized Controlled Trials COVID-19): Implications for Clinical Dental Care COVID-19 Transmission in Dental Practice: Brief Review of Preventive Measures in Italy Coronavirus Disease 2019 (COVID-19): Emerging and Future Challenges for Dental and Oral Medicine Coronavirus COVID-19 impacts to dentistry and potential salivary diagnosis Consistent detection of 2019 novel coronavirus in saliva SARS-CoV-2 Detection in Gingival Crevicular Fluid Viral Load Dynamics in Sputum This article is protected by copyright. All rights reserved and Nasopharyngeal Swab in Patients with COVID-19 Early Transmission Dynamics in Wuhan, China, of Novel Coronavirus-Infected Pneumonia Recommendations for the re-opening of dental services: a rapid review of international sources Mechanisms of Atomization from Rotary Dental Instruments and Its Mitigation Evaluating contaminated dental aerosol and splatter in an open plan clinic environment: Implications for the COVID-19 pandemic Antiviral Activity of Reagents in Mouth Rinses against SARS-CoV-2 Is the oral cavity relevant in SARS-CoV-2 pandemic? Methods to mitigate infection spread from aerosol-generation dental procedures Persistence of coronaviruses on inanimate surfaces and their inactivation with biocidal agents Sodium hypochlorite (dilute chlorine bleach) oral rinse in patient self-care The effect of a low concentration of hypochlorous acid on rhinovirus infection of nasal epithelial cells In vitro biocompatibility study approaches to evaluate the safety profile of electrolyzed water for skin and eye Characterising viable virus from air exhaled by H1N1 influenza-infected ferrets reveals the importance of haemagglutinin stability for airborne infectivity Equine viral arteritis: A respiratory and reproductive disease of significant economic importance to the equine industry Factors affecting stability and infectivity of SARS-CoV-2 Assessment of Air Contamination by SARS-CoV-2 in Hospital Settings Collection, particle sizing and detection of airborne viruses Survival of Enveloped and Non-Enveloped Viruses on Inanimate Surfaces. Microbes Environ Comparative Testing and Evaluation of Nine Different Air Samplers: End-to-End Sampling Efficiencies as Specific Performance Measurements for Bioaerosol Applications Dental procedure aerosols and COVID-19 Biological toxicity of acid electrolyzed functional water: Effect of oral administration on mouse digestive tract and changes in body weight Periodontal effects of 0.25% sodium hypochlorite twice-weekly oral rinse. A pilot study Gingival bleeding on probing: Relationship to change in periodontal pocket depth and effect of sodium hypochlorite oral rinse Transmission of SARS and MERS coronaviruses and influenza virus in healthcare settings: The possible role of dry surface contamination Comparison of suction device with saliva ejector for aerosol and spatter reduction during ultrasonic scaling The Effectiveness of an Aerosol Reduction Device for Ultrasonic Sealers Evaluating aerosol and splatter following dental procedures: Addressing new challenges for oral health care and rehabilitation The Effect of Er:YAG Lasers on the Reduction of Aerosol Formation for Dental Workers Laboratory Equine Arteritis Virus (EAV) strain was kindly provided by the Institute of Microbiology and Parasitology, Veterinary Faculty, University of Ljubljana, Slovenia. The data that support the findings of this study are available from the corresponding author upon reasonable request.