key: cord-0928569-8lmz682s authors: Gardiner, C.; Veall, J.; Lockhart, S. title: The use of UV fluorescent powder for COVID‐19 airway management simulation training date: 2020-04-29 journal: Anaesthesia DOI: 10.1111/anae.15089 sha: 135c2545aa4c09541973a73cb3fac25a9ef5779c doc_id: 928569 cord_uid: 8lmz682s The COVID-19 pandemic has made it imperative to rapidly implement changes to typical medical practice in order to minimise spread of the SARS-CoV-2 virus. Many of these changes are non-intuitive or differ significantly from normal practice. For this reason, we read with great appreciation the timely article by Fregene et al. [1], which describes translational simulation leading to increased preparedness at their institution. With the recognition that aerosol generating procedures are of particular importance to practice due to their high risk of virus transmission, we offer an additional tool for COVID-19 airway simulation training that helped consolidate learning and motivate change to practice in hospitals across Vancouver. of these changes are non-intuitive or differ significantly from normal practice. For this reason, we read with great appreciation the timely article by Fregene et al. [1] , which describes translational simulation leading to increased preparedness at their institution. With the recognition that aerosol generating procedures are of particular importance to practice due to their high risk of virus transmission, we offer an additional tool for COVID-19 airway simulation training that helped consolidate learning and motivate change to practice in hospitals across Vancouver. Here we describe two ways to integrate UV fluorescent powder, as a visual virus surrogate, into scenarios requiring tracheal intubation. Of note, droplet transmission is considered to occur with respiratory droplets which are by definition, > 5 microns, whereas airborne transmission occurs with droplets which are < 5 microns [2] . We use Glo Use of in situ simulation to evaluate the operational readiness of a high-consequence infectious disease intensive care unit Natural ventilation for infection control in health-care settings. Geneva: World Health Organization; 2009. Annex C, Respiratory droplets Glo Germ. www.glogerm.com/history.html (accessed 30/03/ 2020) Figure 1 Glo Germ TM dispersal after airway management breech using model 1 (left) and model 2 (right), illuminated with black light (please note the nasal mucosal anatomising device visible in model 2)