key: cord-0920193-wopo91r2 authors: Huber, Thomas; Goldman, Olivia; Epstein, Alexander E.; Stella, Gianna; Sakmar, Thomas P. title: Principles and Practice for SARS-CoV-2 Decontamination of N95 Masks with UV-C date: 2021-03-04 journal: Biophys J DOI: 10.1016/j.bpj.2021.02.039 sha: 3e7a5ea81908297bf6af749908d0c6371185db05 doc_id: 920193 cord_uid: wopo91r2 A mainstay of personal protective equipment (PPE) during the COVID-19 pandemic is the N95 filtering facepiece respirator. N95 respirators are commonly used to protect healthcare workers from respiratory pathogens, including the novel coronavirus SARS-CoV-2, and are increasingly employed by other frontline workers and the general public. Under routine circumstances, these masks are disposable, single-use items, but extended use and reuse practices have been broadly enacted to alleviate critical supply shortages during the COVID-19 pandemic. While extended-time single use presents a low risk of pathogen transfer, repeated donning and doffing of potentially contaminated masks presents increased risk of pathogen transfer. Therefore, efficient and safe decontamination methods for N95 masks are needed to reduce the risk of reuse and mitigate local supply shortages. Here we review the available literature concerning use of germicidal ultraviolet-C (UV-C) light to decontaminate N95 masks. We propose a practical method for repeated point-of-use decontamination using commercially-available UV-C crosslinker boxes from molecular biology laboratories to expose each side of the mask to 800–1200 mJ/cm2 of UV-C. We measure the dose that penetrated to the interior of the respirators and model the potential germicidal action on coronaviruses. Our experimental results, in combination with modeled data, suggest that a two-minute UV-C treatment cycle should induce a >3-log-order reduction in viral bioburden on the surface of the respirators, and a 2-log order reduction throughout the interior. We find that a dose 50-fold greater does not impair filtration or fit of 3M 8210 N95 masks, indicating that decontamination can be performed repeatedly. As such, UV-C germicidal irradiation (UVGI) is a practical strategy for small-scale point-of-use decontamination of N95s. The recent SARS-CoV-2 outbreak has created a worldwide shortage of personal protective equipment (PPE) which leaves healthcare workers dangerously ill-equipped to aid COVID-19 patients (1). Respiratory viruses such as SARS-CoV-2 can potentially be transmitted through contact, respiratory droplets, and aerosols. WHO recommends droplet and contact precautions for people caring for COVID-19 patients and recommends airborne precautions, such as N95 masks, for circumstances where SARS-CoV-2 aerosol particles are generated (2) N95 masks are filtering facepiece respirators (FFRs) that have at least 95% efficiency for filtering airborne particles (size around 300 nm) and meet the air filtration rating of the U.S. National Institute for Occupational Safety and Health (NIOSH) classification for filtering respirators. Equivalent standards of N95 are FFP2 (European Union), KN95 (China), DS/DL2 (Japan), and KF94 (South Korea) (3) . N95 filtering facepiece respirators for use by the general public in public health medical emergencies are intended for over-the-counter use (4) . A model for a hypothetical influenza pandemic in the US suggested that several billion N95 masks would be required to prevent widespread transmission among the public, which would lead to severe supply shortages (5) . Current guidelines during the COVID-19 pandemic suggest limiting the use of N95 masks to healthcare personnel, while providing low-tech face masks for the general public (6) . Typically, N95 masks are discarded after each use to prevent exposure of infectious material on the respirator to others or the wearer, and extended single use is recommended rather than re-use in the case of pathogens where contact transmission is possible (7, 8) . However, due to shortages of PPE, many healthcare workers are not only wearing N95 masks for extended periods of time, but also reusing them (9) . There are challenges in maintaining the physical and electrostatic properties of N95 masks after certain decontamination methods. The multi-layer sandwich structure of N95 masks, like the 3M model 8210 (Figure 1 ), consists of an outer layer (Coverweb) which faces the environment, middle layers (Filters 1 and 2), and an inner layer (Shell) which faces the user (10) . The 3M 8210 mask materials are polyester for the Coverweb and Shell, polypropylene for Filters 1 and 2, thermoplastic elastomer for the straps, aluminum for the nose clip, and polyurethane for the nose foam. Filters 1 and 2 are the internal filtering medium (IFM), the key material of the N95 mask. The IFM is a proprietary Brownian filtration media which traps particles that collide with a specially treated surface, which is made of electrostatically charged meltblown polypropylene microfibers. These microfibers have cross-sectional diameters in the range of 2 to 10 μm and cross each other to form a 3D porous structure, with up to 90% porosity (3) . The microfibers are electrostatically charged to attract and trap particles and increase filtration efficiency without impeding air flow (11) . Decontamination methods with 75% alcohol or a chlorine-based solution dramatically reduce the filtration performance of N95 masks, likely due to breakdown of the electrostatic charge on the filter material, and are not recommended (3) . On the other hand, ultraviolet germicidal irradiation (UVGI) has been shown to efficiently inactivate pandemic influenza virus applied as aerosols or droplets on several different N95 masks (12) (13) (14) . Recent work has optimized or implemented UVGI (15) , vaporized hydrogen peroxide (VHP) (16) and moist heat (17) for large-scale decontamination of N95s in hospitals. However, there is a need for inexpensive, widely available tools for small-scale mask decontamination. We demonstrate that UV germicidal irradiation represents a powerful tool for small-scale decontamination of N95 masks. To justify a minimum irradiation dosage for safe decontamination, we model the germicidal action of UV irradiation in the filter material of the N95 mask. We show that N95 decontamination can be achieved with commercially-available UV crosslinker devices commonly found in molecular biology laboratories. Similar low-cost UV boxes designed for point-of-use N95 mask decontamination could be rapidly produced and distributed worldwide to alleviate local critical shortages of N95 masks, such as during the ongoing COVID-19 pandemic. [ Figure 1 ] The hemispherical transmittance of a scattering medium is usually measured with an integrating sphere. A simple alternative is to use an optical diffusor, such as an opal glass or filter paper behind the sample (18) . The hemispherical transmittance ( ) can be calculated from the ratio of the transmitted irradiance ( ) and the incident irradiance ( ): To determine the absorbance spectrum of each of the different layers of the N95 mask, we adapted a method normally used for scattering suspensions (18) . We placed a piece of Whatman filter paper as a light-diffuser behind the blank and sample cuvette holder in a double-beam UV-Vis spectrophotometer (Perkin Elmer Lambda 800). We taped a piece of the mask material in front of the filter paper (thickness 0.34 mm; Whatman 3030-917 cellulose chromatography paper 3MM, Sigma-Aldrich) in the sample position. In this way, the lightdiffuser collected a representative sample of the scattered light penetrating the mask material. We recorded spectra with a slit width corresponding to a 2-nm bandpass with an integration time of 0.4 s for each data point sampled in 1-nm intervals between 700 and 250 nm. Transmittance measurement with UV-C radiometry J o u r n a l P r e -p r o o f We used a high-intensity 254-nm UV light source (Analytik Jena US, UVP CL-1000) and a UV-C light meter (General Tools UV254SD) to measure the irradiance with and without a piece of each different layer of the N95 mask in front of the sensor. We calculate the transmittances using equation 1. We also used a 254-nm UVP Compact UV lamp that facilitates measuring the transmittance of the materials without the need to turn off the lamp when changing the samples. The transmittances were 22% (16 to 29), 21% (16 to 26), 14% (9 to 20) and 0% (0 to 5) for the Coverweb, Filter 1, Filter 2 and Shell, respectively. Values in parentheses are 95% confidence intervals (95% C.I.) from nine repeated sets of measurements, including the dominant contribution from the specified measurement accuracy of the UV254SD meter, which is ±0.082 mW/cm 2 . The lower power of the UVP Compact UV lamp as compared with the UVP CL-1000 source did not allow a non-zero measurement for the optically dense material of the Shell layer. Therefore, we used a densitometric method to quantify more accurately the transmittance of the Shell layer. We used photochromic intensity indicators (New UV Intensity Labels, UV Process Supply, Chicago) for direct UV densitometry measurements ( Figure 2 ). These yellow-colored labels change gradually to green when exposed to UV. We determined the UV dose-dependent change in color by exposing a set of labels to increasing UV dosages in the UVP CL-1000 source. We simultaneously recorded the UV irradiance with the UV254SD meter using a one second sampling interval to obtain the actual exposure dosage by numerical integration. We quantified the color change using a flatbed scanner (Epson) and Fiji/ImageJ for image analysis. The red channel of the RGB image showed the largest change of photochromic effect. Exponential fitting of the dose-dependent data with Prism (Graphpad) showed that a dose of 88 mJ/cm 2 (95% C.I. 77 to 103) yields a half-maximum photochromic effect. We exposed labels sequentially through the Shell layer material for 60 min in the UVP CL-1000 source. We quantified the color changes of these labels under identical conditions to the labels for the calibration. The 60-min exposure with an integrated UV surface dosage of 17119 mJ/cm 2 resulted in a color change that corresponds to a transmitted dosage of 22 mJ/cm 2 (95% C.I. 17 to 26). The ratio of the transmitted and surface dosages gives the total transmission, which is 0.13% (95% C.I. 0.10 to 0.15). We noticed that the color change across the label was uneven, for example with less changes beneath a wrinkle in the Shell layer, due to the manufacturing of the dome-shaped structure. Next, we exposed an array of intensity labels to map the intensity distribution of the transmitted light. We used a 180-min exposure with 49382 mJ/cm 2 surface dosage to map the transmitted light intensity distribution in a 5-cm 2 region under the Shell layer material. The average color change corresponds to a transmitted dosage 106 mJ/cm 2 (95% C.I. 97 to 116), which gives 0.21% (95% C.I. 0.20 to 0.23). The one standard deviation wide range of color changes corresponds to a range of transmitted dosages from 0.13% to 0.34%. The 95% range J o u r n a l P r e -p r o o f of color changes observed for the transmitted light corresponds to a range of transmitted dosages from 0.07% to 5.7%. Modeling the UV-C light distribution in the multilayer structure of the N95 mask The transmittance of the i-th layer ( ) is related to its thickness ( ) by an attenuation coefficient ( ): We define a depth-dependent attenuation coefficient as a step function corresponding to the attenuation coefficients of all n layers: Integration of the depth-dependent attenuation coefficient yields the optical thickness ()) at depth ( ): The depth-dependent transmittance ( ) is related to the optical thickness by: The model neglects the contributions of multiple reflections between the layers of materials, which is small due to the poor reflectance of materials in the short wavelength UV-C region. We confirmed the validity of our model by control experiments measuring the transmittance of stacks of identical layers of material that give a linear increase of total optical thickness with the number of layers. The optical thickness in the reverse direction () 1 ) is obtained by integration of the interval starting at the depth ( ) and ending at the combined thickness of all layers (∑ ): Here we define the depth-dependent transmittance in reverse direction ( 1 ) as: The depth-dependent exposure dosage (6 ) is given by the surface exposure in the forward direction (6) and the surface exposure in reverse direction (6 1 ) and the depth-dependent transmittances: 6 = 6 + 6 1 1 # 9 Modeling the virus viability in the N95 mask We define the survival (;) as ratio of the number of infectious virions after exposure (") and before exposure (" , ): The simplest dose-dependent survival function (; 6 ) for single-hit kinetics of UV inactivation of virus infectivity relates the exposure dosage ( (6)) to an UV rate constant (k): We also use a second model with a secondary population of viruses with a different rate constant (=′) that comprises a fraction (?) of the total population: ; 6 = 1 − ? exp −=6 + ? exp −= @ 6 # 12 The average survival (〈;〉) can be calculated from a depth-dependent density of viruses before exposure (C , ), the survival function and the depth-dependent exposure dosage: 〈;〉 = * C , ;.6 / ∑ + 3 , * C , The figures are modeled with a constant value for C , corresponding to uniform contamination of the mask layers. We also use a unit value for the thickness for each layer ( ). Together these two choices give each layer the same share to the overall virus survival. A more advanced model would include a nonlinear distribution of virus load trapped across the different layers of the mask, based on the adsorption kinetics of the viral particles on the internal surface area of the various layers of different microfiber materials. Physical dimensions. We determined the thickness and areal density for each of the materials of the four layers of the 3M 8210 N95 mask (see Figure 1 ). The Coverweb, Filter 1, Filter 2 and Shell layers are respectively 0.20 mm, 0.36 mm, 0.41 mm and 0.90 mm thick, and have areal densities of 4.2 mg/cm 2 , 5.1 mg/cm 2 , 5.5 mg/cm 2 and 16.4 mg/cm 2 . The thickness and areal density measurements have relative errors of +/-20% and +/-15%, respectively. Note that the thickness of these highly compressible materials is very difficult to measure, and we obtained our best estimated of the thickness by limiting the manually applied measurement force on a standard Vernier caliper (Mitutoyo). Light microscopy revealed that the fibers within each layer consists are 16 μm (95% CI, 12 to 20) thick in the Coverweb, 5.5 μm (95% CI, 3.9 to 7.1) thick in Filter 1, 2.8 μm (95% CI, 0.7 to 4.8) thick in Filter 2, and 21 μm (95% CI, 19 to 24) thick in the Shell. The packing volume fraction of the microfibers can be approximated as C/F , , where σ is the areal density, ρ is the density of the bulk polymer, and d 0 is the layer thickness. With a density for neat polyester as 1.68 g/cm 3 (for polyethylene terephthalate) and for neat polypropylene as 0.9 g/cm 3 , we estimate the packing volumes fractions as 11%, 15%, 16%, and 13% for Shell, Filter 2, Filter 1, and Coverweb, respectively. The relative internal surface area of the microfibers compared to the macroscopic area of the filter layer can be approximated as 4C/F , where σ is the areal density, ρ is the density, and d is the fiber thickness. We estimate the relative internal surface areas as 19 for the Shell, 87 for the Filter 2, 41 for the Filter 1, and 6 for the Coverweb. Penetration of UV-C light into N95 mask layers. A central question is how much germicidal UV light penetrates the different layers of an N95 mask. The optical transmittance of the mask layers is hard to quantify for short-wavelength UV-C light, especially for the optically dense Shell layer of the N95 mask studied here. We used three complementary methods, spectrophotometry, radiometry, and densitometry, to determine that the optical transmittance of the Shell layer is only 0.1% of the incident irradiance. [ Figure 3 ] Figure 3 shows the spectrophotometric optical transmittance of the different layers of the 3M 8210 N95 mask. The transmittance of the two middle layers (Filter 1 and Filter 2) in the UV-C range is higher than that of the inner layer (Shell). The Shell transmits little UV-C light because it is made from polyester, which is an aromatic polymer that absorbs UV. By contrast, Filters 1 and 2 are made of polypropylene, which has low specific UV absorption besides losses due to light scattering. The Coverweb, despite being made out of UV-absorbing polyester, is the thinnest of all layers and shows transmittance that is similar to that of the filter layers. Since the stray light performance of the spectrophotometer limits the accuracy of the measurements by systematically overestimating transmittance, we employed UV-C radiometry as an alternative approach to measure the spectral transmission of N95 mask materials (Setup 2 in Fig. 3d ). The transmittances are 15%, 27%, 21% and 0.11% for the Coverweb, Filter 1, Filter 2 and Shell, respectively. The limitation of Setup 2 is that the sample and the digital radiometer have to be placed into the UVP CL-1000 photocrosslinker before the UV light can be turned on which makes it difficult to measure fluctuations of the intensity. In Setup 3, we used the UVP Compact UV lamp, enabling us to perform repeated measurements with and without samples to determine the transmittance based on the radiometer readings. The calculated transmittances were 22% (16 to 29), 21% (16 to 26), 14% (9 to 20) and 0% (0 to 5) for the Coverweb, Filter 1, Filter 2 and Shell, respectively. Since the irradiance of the Compact UV lamp was lower as compared to the CL-1000, the transmitted light was too low to give any readings different from zero on the radiometer. To determine the transmittance of the Shell layer material, we resorted to a densitometric approach using photochromic UV-C indicator stickers. Germicidal UV sources. The 254-nm line of the mercury-vapor emission spectrum is the predominant line of a low-pressure mercury-vapor lamp manufactured with a soda-lime glass bulb, which absorbs the 184-nm line. The 254-nm UV-C light efficiently inactivates singlestranded RNA viruses as seen in the germicidal action spectrum (Figure 3c ) (19) . The action spectrum is for the MS2 bacteriophage, which is a positive strand RNA virus, similar to the coronaviruses of interest. The shape of the germicidal action spectrum should be independent of the particular virus, but instead should depend on the underlying photochemistry of the UV damage of the RNA genome. Recently, germicidal UV light emitting diodes (LEDs) became commercially available that emit in the 260 to 280 nm range. [ Figure 4 ] UV-C light sensitivity of SARS-CoV. The sensitivity of RNA viruses depends on several factors, such as genome size and base composition (22) . Moreover, the UV-C dose-dependent inactivation of viruses is known to deviate from a simple first-order decay model (23) . In absence of detailed data on the novel coronavirus SARS-CoV-2, we use literature data for the closely related virus SARS-CoV (20) , as the UV-C sensitivity of related viruses is roughly constant after accounting for genome size (24) . Figure 4 shows a semi-logarithmic plot of the dose-dependent inactivation of SARS-CoV measured by Kariwa et al. (20, 21) . The endpoint dilution assay quantifies the virus titer by serially diluting the treated virus stock, inoculating Vero E6 cells with the serial dilutions, observing the cytopathic effect under a microscope after 48 hours incubation to quantify the percentage of cell death, and calculating the fifty-percent tissue culture infective dose (TCID 50 ). We model the data as a double-exponential decay function that enables interpolation of the data points in a meaningful manner. The fast component is 98.6%±0.4% and has a UV-C sensitivity of 0.522±0.040 cm 2 /mJ. The slow component is 1.4%±0.4% and has a sensitivity of 0.066±0.003 cm 2 /mJ. The occurrence of a slow component of UV-resistant virus is unexpected. Exponential survival curves can be explained by a single hit to kill model (25) . Lytle and Sagripanti compare the UV-C sensitivities of a large number of different virus families and state that only the Herpesviridae family consistently exhibits two-component survival curves (24) . Therefore, it is likely that the double-exponential decay function necessary to fit the Kariwa et al. data reflects an experimental issue. We interpret the slow component as virus trapped at the bottom of the sample and the fast component as freely diffusing virus particles. If so, the fast rate constant would represent the averaged depth dependent UV-C dosage scaled by the sensitivity of the virus. The slow component would result from the attenuated UV-C dosage reaching the bottom, caused by the inner-filter effects of the tissue culture media used in the experiments (see the Discussion section). The final plateau with a value of 17±2 TCID 50 /mL value, which corresponds to a fraction of 5×10 -7 , corresponds to the detection limit of the assay, which is likely due to cytopathic effects of protein components of the virions that are not inactivated by the UV-C irradiation, since the assay in principle does not discriminate cytopathic effects from true infectivity as other assays. Modeling the UV-C light distribution in the N95 mask. The relationship of the total optical transmittance and thickness for a scattering and absorbing media should follow an exponential relationship, in which an attenuation coefficient replaces the absorption coefficient of the Beer-Lambert law for non-scattering media. It is based on integrating the timedependent photon diffusion equation often used to model light penetration into scattering media (26) . To calculate the attenuation coefficient from the total transmission, we need the actual thickness of each layer. We use the radiometric UV-C transmittance data to model the depth-dependent UV-C dosage in an N95 mask. From the preferred transmittance values (Fig. 3e) , we calculate the absorbances of the four layers calculated from the transmittance data are 2.68, 0.85, 0.68 and 0.66 for the Shell, Filter 2, Filter 1 and Coverweb, respectively. We model the depth-dependent cumulative absorbance of all layers as a piece-wise linear function corresponding to the sum of the absorbances, with one function from each side. These depth-dependent absorbance functions allow calculation of the depth-dependent transmittance, and therefore the local UV-C dosage. Figure 5A shows a semi-logarithmic plot with three curves corresponding to the local UV-C dosage as a function of the relative position in the four layers of the N95 mask (Shell, Filter 2, Filter 1, and Coverweb) for three cases of illumination. The first case is illumination from the inside surface of the mask. The orange curve shows the local dosage for illumination from the user-facing inside of the mask with a surface UV-C dosage of 1000 mJ/cm 2 . Due to the high absorbance of the polyester material of the Shell layer, the local dosage rapidly drops to 2 mJ/cm 2 at the interface between the layers Shell and Filter 2. It further drops to 0.29 mJ/cm 2 at the interface between Filter 2 and Filter 1, and 0.06 mJ/cm 2 at the interface between Filter 1 and Coverweb. The residual local dosage at the exit on the other side of the mask is only 0.014 mJ/cm 2 . The second case is illumination from the outside surface of the mask. The green curve shows the local dosage for illumination from the environment-facing outside of the mask with a surface UV-C dosage of 1000 mJ/cm 2 . The dosage drops to 220 mJ/cm 2 at the interface between Coverweb and Filter 1, to 46 mJ/cm 2 at the interface between Filter 1 and Filter 2, and to 6.5 mJ/cm 2 at the interface between Filter 2 and Shell. The exit dosage at the inside surface is 0.014 mJ/cm 2 . The third case is for illumination from both sides of the mask. The black curve shows the local dosage for illumination from both sides of the mask with a surface UV-C dosage of 1000 mJ/cm 2 , each. The local dosage is 8.6 mJ/cm 2 at the Shell to Filter 2 interface, 46 mJ/cm 2 at the Filter 2 to Filter 1 interface, and 220 mJ/cm 2 at the Filter 1 to Coverweb interface. The minimum of the black curve is in the core of the Shell material, close to the Filter Modeling the virus viability in the N95 mask. The local UV-C dosage calculated for the three cases of illumination together with the UV-C dose-dependent inactivation of SARS-CoV enables an estimate of the local residual virus viability in an irradiated N95 mask ( Figure 5B ). The orange curve is for the first case with illumination from the inside surface of the mask. The first half of the Shell layer is efficiently decontaminated with 0.07% local viability in the center of the Shell. However, the sharp rise of the local viability to 34% at the interface of Shell and Filter 2 shows that the illumination from the inside of the mask is insufficient to decontaminate the highly porous material of the Shell layer. Note that the optically dense Shell layer has a thickness of 0.90 mm, which is almost as much as the combined thickness of all other layers (Filter 2 is 0.41 mm, Filter 1 is 0.36 mm and Coverweb is 0.20 mm thick). In contrast, the green curve, for the second case where the mask is illuminated from the outside, shows efficient decontamination of the three layers, Coverweb, Filter 1 and Filter 2, with 4.3% local viability at the interface of Filter 2 and Shell, but little or no decontamination of the Shell. For the third case with illumination from both sides, the local viability throughout the mask is very low. The smallest UV-C dosage inside the core of the Shell material results in 3% local virus viability. The integrated local viability yields the averaged virus viability in the mask, which is 0.3% for illumination from each side together of the mask with 1000 mJ/cm 2 surface dosage. Here we analyze the dosedependent decontamination levels and the effect of different models of UV-C sensitivity on the achievable degree of decontamination. As explained in the discussion, previous literature disagrees on different UV-C sensitivity of coronaviruses and other related viruses (20, 21, (28) (29) (30) . Therefore, out of an abundance of caution, we determined the proper UV-C dosage to sufficiently decontaminate N95 masks based on three different models of virus viability as a function of UV-C dose. ( Figure 6B ) We also estimated local viability as a function of mask position assuming a standard 1000 mJ/cm 2 exposure ( Figure 6A ). [ Figure 6 ] Based on the data from Figure 3E , Model 1 predicts virus inactivation as a function of UV-C exposure, accounting for the possibility of virus populations with different UV-C sensitivities (20, 21) . The predicted local viability (black curves in Figure 5B and Figure 6A ) shows the difficulty to inactivate the virus in the core of the Shell and, to a smaller extent, in Filter 2, but the model demonstrates sufficient decontamination to prevent surface transmission for re-use of an N95 mask, despite the 1.4% of the virus population that shows reduced UV-C sensitivity. However, we suspect that the UV-C sensitivity predicted by Kariwa et al. may be underestimated due to confounding inner filter effects in the experimental assay (see "Potential confounds in measurement of viral UV-C sensitivity" in the discussion). Therefore, we created Model 2 (cyan curves in Figure 6 ), which assumes that the major population, consisting of 98.6% of virus, has a UV-C sensitivity of 0.522 cm 2 /mJ based on observations from Darnell et al. (2004) . The local virus viability in the Shell is similar in both J o u r n a l P r e -p r o o f Models 1 and 2. However, because of the lack of the UV-C resistant minor population in Model 2, more virus is inactivated in the Filter 2 since the UV-C resistant minor population is the main contributor at low percentage values of local viability. Model 3 (red curves in Figure 5 ) is similar to Model 2, but assumes a higher UV-C sensitivity of 3.77 cm 2 /mJ based the measured UV-C sensitivity murine hepatitis virus (MHV) coronavirus in aerosol (30) . Model 3 suggests complete inactivation of virus in all layers of the mask, including the highly shielded core of the Shell. We calculated the total virus viability averaged over all layers, as obtained from the integrated local viabilities, for the three different models as a function of surface UV-C dosage ( Figure 6B ). The curves for Model 1 (black) and Model 2 (cyan) are similar for UV-C dosages up to 1000 mJ/cm 2 , before they diverge. The surface dosages from each side necessary to achieve 2-log order reduction to 1% total viability are 637 mJ/cm 2 for Model 1 and 575 mJ/cm 2 for Model 2. For 3-log order reduction to 0.1% total viability, the dosage for Model 1 with 1765 mJ/cm 2 is already noticeably larger than the 1068 mJ/cm 2 for Model 2. Model 1 fails to achieve 4-log order reduction for dosages up to 5000 mJ/cm 2 , where the total virus viability reduced to 0.011%. Model 2, on the other hand, reaches 4-log order reduction to 0.01% at 1597 mJ/cm 2 , 5-log order reduction at 2145 mJ/cm 2 , and 6-log order reduction at 2705 mJ/cm 2 . In comparison, the high UV-C sensitivity in Model 3 predicts 3-log order reduction at 148 mJ/cm 2 and 6-log order reduction at 375 mJ/cm 2 . Model 3 shows robust UV-C sensitivity and corresponds to a 3-log reduction with notably lower UV dosage compared to Model 1 and Model 2. In this section, we review literature and outline principles and points of consideration when implementing UVGI decontamination of N95 masks. The optimization of the UV-C dosage for efficient decontamination of a mask depends on several design parameters. What degree of reduction of virus viability is desired? Is it necessary to decontaminate interior layers of the mask that are inaccessible for direct contact? Does the applied UV-C dosage negatively affect the performance of the mask? Is it practical to deliver the necessary dosage? N95 mask filtration efficiency for aerosolized viruses. Aerosolized MS2 virions permeate N95 masks with a peak permeability exceeding 5% for particles with approximately 50 nm diameter (31, 32) , but the permeability is below 1% for aerosolized MS2 at 500 nm average particle diameter (33) . Studies have demonstrated that N95 masks trap MS2 virions in small aerosol particles (with 141 nm median diameter) preferentially in the middle layer, whereas virions in larger aerosol particles (median diameter 492-nm) are preferentially trapped in the outer layer (34) . The only study that used aerosolized adenovirus and influenza virus found levels of permeability comparable with the results from the MS2 model virus, even though the MS2 virion (27.5 nm diameter) is smaller than influenza virus (80 to 120 nm diameter) or SARS-CoV-2 (50 to 200 nm diameter) (35) . This suggests that the size of the aerosol particles carrying virions, not the size of the virions themselves, are the important factor for the efficacy of N95 mask's mechanism of action. Hospital samples of SARS-CoV-2 aerosols collected during the outbreak in Wuhan, China showed viral RNA present in a distribution of different sized aerosols with multiple peaks: one in submicron region (particle diameter of 250 nm to 1 μm) and another in the supermicron region (particle diameter larger than 2.5 μm), but also in even smaller particles (range 10 nm to 250 nm) (36) . It is noteworthy that live virions in environmental aerosols are key to transmission, and it is difficult to quantify compared to viral RNA alone. Quantification from Liu et al. is based on RT-qPCR assays of viral RNA instead of culturing viable virions (37) . Based on studies using a similar distribution of different-sized MS2 aerosol particles, a large fraction of the supermicron and submicron SARS-CoV-2 particles would be trapped in the outer layer of N95 masks, whereas the smaller particles should get trapped in the microfiber material of the middle layer. Routes of transmission via N95 mask extended use/reuse. For decontamination of N95 masks, it is important to consider which parts of the multilayer structure provide potential viral transmission risk. Risk of contact transmission is due to handling the contaminated surface of a mask (8) . It is also possible that virus could be re-aerosolized from the mask due to the airflow from breathing, coughing or sneezing. A study of simulated coughing through an N95 mask contaminated with the MS2 virus demonstrated that only a small percentage of virus was released (38) . However, SARS-CoV-2 RNA was present at high levels in large particle aerosols in hospitals during the COVID-19 outbreak, which raises concerns that larger particles are more efficiently re-aerosolized under similar conditions (36, 39) . Our results demonstrate that inner layers of the N95 mask will inevitably receive different amounts of dosage than outer layers. Decontamination methods must consider efficacy of inactivating virions most importantly on the masks' surface, as well as on the inner layers of the mask. Potential confounds in measurement of viral UV-C sensitivity. The prediction and measurement of the sensitivity of novel viruses to germicidal UV light is an important and difficult problem (22, 24, 40) . Several studies have investigated UV-C sensitivity for coronaviruses, including SARS-CoV (20, 21, 28, 41, 42) and SARS-CoV-2 (43). A confound in these studies is that the virus preparations are made in Dulbecco's Modified Eagle Medium (DMEM) including 10% fetal bovine serum (FBS) and other additives, such as antibiotics and antifungals. The high protein content of FBS results in a high absorbance at 254 nm. We determined that 10% FBS contributes 1.54±0.04 and DMEM contributes 1.12±0.02 absorbance at 254 nm. The absorbance is about 2.66±0.04 per 1-cm pathlength with about 58% contribution from FBS and the rest from DMEM. Therefore, even shallow layers of virus suspension will have a high absorbance that results in substantial inner filter effects that reduce the available UV-C dosage in a depth-dependent fashion. (For clarity, we would like to note that "inner filter effect" is a principle in fluorescence spectroscopy and that has no relation in concept to N95 mask filters.) These inner filter effects likely explain the discrepancies between two studies with SARS-CoV, where the reduction of the filling height of the virus suspension from 1 to 0.25 cm resulted in 40-fold increase of UV-C sensitivity from 0.012 to 0.477 cm 2 /mJ (20, 28) . The UV-C sensitivity of a different coronavirus, murine hepatitis virus (MHV), in aerosol form was 3.77 cm 2 /mJ (30) , which is even 8-fold higher than SARS-CoV in the shallow solution. The RNA genome size of the different coronaviruses (MHV, SARS-CoV and SARS-CoV-2) is very similar (44, 45) , and, therefore, they should have intrinsically similar UV-C sensitivities (22, 24, 40) . The differences of UV-C sensitivities are likely due to the different form, aerosol versus shallow solution. Since the small diameter of the aerosol droplets will have negligible inner filter effects, UV-C sensitivities measured in aerosol is most applicable, although to perform these experiments on additional viral species is prohibitive due to requisite biosafety measures. UV-C inactivation of the Berne virus or equine torovirus, closely related to coronaviruses and with a similar RNA genome size (46) , has been measured in very shallow preparations of about 0.05-cm path length (29) . The corresponding UV-C sensitivity is 3.24 cm 2 /mJ, which is very close to that for the MHV aerosols, additionally supporting that the high UV-C sensitivity inferred from the aerosols and is most closely reflected by values determined by solutions with minimal inner filter artifacts. Future studies of the UV-C sensitivity of SARS-CoV-2 should carefully address the issue of UV attenuation due to the sample media composition, for example, by using very thin solution layers or by using virus purified in low UV-absorbing buffers. Potential methods for validating N95 decontamination. In addition to developing models that predict UV-C penetration into masks and inactivation of SARS-CoV-2, the reduction in viral bioburden in N95 masks could potentially be measured directly. Oral et al. demonstrated the effectiveness of VHP decontamination by applying SARS-CoV-2 to the surface of an N95 mask and assessing the effect of treatment through quantifying extracted of viable virus from mask sections (47) . Future work could employ this technique to assess the ability of UV-C to affect viability of SARS-CoV-2. However, this method of measuring bioburden reduction has a key limitation; the static application of the virus to the respirator surface does not accurately model the penetration of aerosolized virus deeper into the respirator. While virus on the surface likely poses the greatest hazard to the user and others, one study using the MS2 bacteriophage as a model has shown that a small percentage of viable virus can be re-aerosolized from an N95 respirator. (27) Aerosolization of the virus prior to exposure is prohibitively dangerous, requiring a biosafety level 4 (BSL-4) laboratory. Small-scale implementation of UVGI for N95 masks. Many groups have focused on largescale chambers to accommodate up to 27 masks in one cycle with two planar 12 UV-C bulb arrays (48, 49) . However, biosafety cabinets and even medium-scale UVGI boxes that hold 6 masks demonstrate variability in UV dosage as a result of distance, angle of incidence from light source, and orientation and shape of the masks (50, 51). The higher UV-C doses needed to compensate for this variability and ensure decontamination may increase the risk of compromising masks' structural integrity. By contrast, a single-mask decontamination system can ensure that a controlled, carefully measured dose UV-C dose is delivered to the mask. In addition, such a system would be cheap and practical for point-of-care decontamination outside of hospital settings. We used a commercial UVP Crosslinker that has 5x 8W 254-nm mercury vapor bulbs in an enclosure. A microprocessor controls the UV-C exposure and stops the irradiation when the desired energy is delivered. Since the bulbs are only at the top of the enclosure, we needed to use two sequential exposures, flipping the mask upside-down in-between them. The need to flip the masks adds another handling step with the risk of viral contamination. Point-of-use UV-C decontamination of N95 masks could prove useful to frontline workers, such as firefighters, transit workers, and grocery store employees, who would need to decontaminate small numbers of respirators and would lack access to the bulk respirator decontamination systems now being implemented in hospitals. Photodegradation of the masks. One concern with UV-C decontamination of N95 respirators is that photodegradation could limit the number of times that a mask can be reused safely. The photodegradation of polypropylene filaments by UV-C irradiation has been studied with mechanical strength tests and Fourier transform infrared (FTIR) spectroscopy, which has demonstrated the formation of alcohols, peroxides, ketones, aldehydes, carboxylic acids, and anhydride reaction products (52, 53) . The initiation of photo-oxidation reaction cascades of polypropylene, especially at wavelengths longer than 290 nm, is thought to originate from chromophoric groups, such as hydroperoxides, which in turn are formed in an autocatalytic process (54) . The photodegradation of the polyester poly(ethylene terephthalate) involves photo-oxidative reactions leading to chain scission and the generation of carboxyl end groups (55, 56) . The photodegradation of polypropylene and polyester both rely on photo-oxidative reactions involving reactive oxygen species (ROS). Several studies have previously examined the effect of UV-C irradiation on N95 respirator filtration and fit. However, their findings vary widely. According to Lindsley et al., for four tested N95 models, the mechanical strength of one or more layers was significantly reduced at exposure doses higher than 120000 mJ/cm 2 sequentially applied to each side (57) . The researchers observed only minor changes in particle penetration and flow resistance as a result, suggesting that a mask could safely endure 120 decontamination cycles of 1000 mJ/cm 2 (the CDC-recommended standard). However, this study only looked at filtration efficiency, rather than quantitative fit factor, which is inversely proportional to the total inward leakage of particles through a worn respirator. Fit factor therefore measures overall respirator performance, including both filtration efficiency and fit to the user's face. Smith et al. found that the fit factor of masks was reduced (albeit not below the minimum standard for N95s) after a dose of 18000 mJ/cm 2 via a germicidal lamp in a biosafety cabinet, corresponding to only 18 such cycles (58) . We note that Smith et al. used different models of N95 masks (1860, Aura 1870+, industrial 8511) manufactured by 3M, although no data were provided investigating differential effects of UV-C for each model. Another study of the effect of UV-C irradiation on the fit test performance of N95 masks did not have data for the 3M 8210 mask due to the current supply shortage (59) . They found that fit factor began to decrease even before 10 decontamination cycles, but the UV-C dose received by the mask was not specified, similar to a report by Fischer et al. (20) . We conducted our own tests, exposing two 3M model 8210 N95 respirators to repeated doses of UV-C (with either 5000 or 10000 mJ /cm 2 exposure doses per side). Before and after each cycle, the masks were donned by a volunteer, and the quantitative fit factor was measured using a TSI PortaCount Pro Plus. The quantitative fit factor is defined as the ratio of concentrations of 0.02-1 µm particles outside and inside the mask, and is decreased both by particle penetration and poor fit. For N95 masks and other disposable respirators, the PortaCount Pro can measure a maximum fit factor of 200 (which would correspond to the mask filtering at least 99.5% of particles). One mask was subjected to fourteen exposure cycles (5000 mJ/cm 2 per cycle per side), and the other to one long exposure (20000 mJ /cm 2 exposure doses per side) followed by six shorter cycles (10000 mJ/cm 2 per side) giving 80000 mJ/cm 2 total dosage per side. Both tested masks maintained a fit factor of 200 during both normal breathing and deep breathing throughout for exposures up to 50000 mJ/cm 2 total dosage per side, which would correspond to fifty decontamination cycles with 1000 mJ/cm 2 each per side. We caution that this result is likely dependent on the model of N95 used, which may contribute to the inconsistency of results obtained from the literature. The company 3M has recently posted a technical bulletin on the impact of decontamination methods on selected N95 mask models from their program, including the 3M 8210 model we used in our experiments. They evaluated five UV-C decontamination systems and found that all of them pass the filtration efficiency and fit tests for five or more reprocessing cycles with exposure dosages of ≥ 1000 mJ/cm 2 on each side, and in one case up to a cumulative lifetime exposure of 100000 mJ/cm 2 (60) . Further testing is needed on other N95 models to determine the number of decontamination cycles that they can withstand without compromise. We did observe that the UV-C irradiation of our N95 masks resulted in a slight odor of the masks that appeared to originate from the polyester material of the Shell layer, since the odor was similar upon irradiation from both sides or only the inside, where all the light is absorbed by the Shell layer. The odor originates from the UV-C irradiated mask itself and not any residues from wearing the mask, since a never-worn, new mask gives the same result. The odor is weak and dissipates rapidly, but nevertheless might reduce the acceptance of the UV-C decontamination of N95 masks for sensitive individuals. We also irradiated a N95 mask in a nitrogen atmosphere to test the role of ROS in the odor formation during photodegradation of the N95 mask. As compared with a mask irradiated in air, the nitrogen atmosphere dramatically reduced the subjective odor formation. While the ROS exposure might aid with virus inactivation, the UVC radiation alone should be sufficient for mask decontamination. Nitrogen can easily be purified from air by filtration, and it could be used for UV-C decontamination equipment to reduce to odor formation and thereby improve the user acceptance of the decontaminated masks. Others have described nutty/smoky odor of masks after UV-C decontamination and recommended to allow for off-gassing time when feasible (48) . Odor has been reported for moist heat decontamination methods as well (61) . Present and future importance of N95 emergency reuse. Epidemiological reports indicate that the number of infectious disease outbreaks tripled between 1980 and 2010 (62), indicating a high likelihood of future moments of acute need for PPE such as N95 masks. It is difficult to prepare or stockpile N95 masks supplies in anticipation of this, given that current models of N95s can have a shelf life of 5 years, and decrease in effectiveness after their manufacturer-designated expiration date (7, 8) . Furthermore, challenges in increasing N95 production may not allow demand to be reached quickly enough during critical early moments of the spread of a disease and suggests that emergency N95 reuse is a necessary option to maintain. We note that two months after initial shortages of N95s due to COVID-19, demand has still not been met for health care workers treating infected individuals (63) . Therefore, we suggest that decontamination methods, such as UVGI of N95 masks, be considered as a feature of preparedness for times of acute need of PPE. The experiments that went into this paper were performed during the extraordinary circumstances of working from March to May in the epicenter of the spring peak of the COVID-19 pandemic in New York City. Our study provided the foundation for the Rockefeller University N95 mask reuse with decontamination program where we used Stratalinker UV-C sources and later in-house engineered UV-C irradiators. The program allowed the University to conserve N95 mask supplies and enabled critical University personnel to safely use mass transportation. The results of our study were disclosed as a preprint (64) in the beginning of June 2020. Preprints are snapshots in time of science that sometimes is in rapid flux. Since then, related results were published in several preprints and published papers discussed below (36, (65) (66) (67) (68) (69) (70) (71) (72) (73) (74) (75) (76) (77) (78) (79) (80) . Storm et al. measured viral viability over time as wet and dry droplets of SARS-CoV-2, both exposed and unexposed to UV-C radiation (77) . The authors report a decay time constant for single exponential decay function fit of the normalized viral viability of wet virus over time. From the reported inactivation time constant of 1.0 +/-0.1 s and the UV-C power density of 0.849 mW/cm 2 , we calculate the corresponding to a UV-C sensitivity of 1.18 +/-0.12 cm 2 /mJ). However, we found by inspection and re-fitting of their tabulated data that about how much of the virus must have been inactivated at shorter exposure times before their first time point. Moreover, the limited amounts of infectious particles used for each experiment does not allow detection of more highly UV-C resistant fractions. Overall, the data from the Storm et al. paper present an advance since the authors were able to obtain results for SARS-CoV-2 in a BSL-4 laboratory, and they avoided the above-mentioned issues with inner filter effects of the protein-rich tissue culture media by using very small droplet volumes (5 μL). We calculate the UV-C dosage of 5.9 or 11.7 mJ/cm 2 needed to achieve 3-Log or 6-Log order, respectively, of virus inactivation from this new value for the UV-C sensitivity of SARS-CoV-2. Bianco et al. reported in a preprint that UV-C dosage of 3.7 mJ/cm2 was sufficient to achieve a 3-log order inactivation of SARS-CoV-2 suspended in tissue culture media in a 1-mm thick layer (65), but their data lack the information at low UV-C dosages necessary to calculate the UV-C sensitivity. Two studies addressed the light propagation inside a N95 mask. Sears et al. modeled the effects of uneven UV-C exposure of masks from two sides due to mask curvature and they J o u r n a l P r e -p r o o f suggest the use of multidirectional UV-C irradiation to improve decontamination (76) . Lilge et al. determined the optical scattering and absorbance coefficients of several N95 mask materials using diffuse transmission and reflection measurements with an integrating sphere and an array spectrophotometer, and they used these parameters for Monte Carlo modeling the light distribution within the layers of the mask (70) . Their modeling of the single-sided light distribution within the 3M 8210 mask suggests about four-log order reduction from the surface light fluence. The integrating sphere data now allow us to extend our own modeling to include the effects of UV-C reflectivity between layers of the N95 mask. Figure 7 shows the results of the model described in the Appendix. The model suggests that an exposure dosage with 1000 mJ/cm 2 from both sides of the mask, the minimum internal local dosage will be 28 mJ/cm 2 , which is sufficient to yield better than Log-6 inactivation of SARS-CoV-2 based on the data from Storm et al. Notably, this minimal local dosage calculated from the model including reflections is four-fold higher as compared to the model presented in Figure 5 , despite using the same experimental values of the transparency for each layer. Other studies addressed the rate of viral inactivation within an N95 mask. Kayani et al. measured inactivation over time for several pathogens including the MS2 virus on the surface of two N95 masks, including the 3M 1860. They found that a dose of approximately 2 J/cm 2 yielded a >4 log-order reduction in MS2 surface bioburden (69) . Golovkine et al. performed a similar study using SARS-CoV-2, and for the 3M 1860 respirator, obtained similar results: a dose ranging from 900-1620 mJ/cm 2 on different areas of the mask achieved a 3.7 log-order reduction of virus on the mask surface. However, they found that the same does achieved only a 1.7-log-order reduction on a 3M 8210 mask (68) . Ozog et al. performed a similar study on five different N95 respirators, including both the 3M 1860 and 3M 8210; similarly, they found that a 1.5 J/cm 2 of exposure per side reduced SARS-CoV-2 bioburden on the 3M 1860 facepiece below the limit of detection, but failed to do so on the 3M 8210 facepiece (81) . They suggest that mask materials with hydrophilic properties, such as the 3M 8210, may have absorbed the virus applied to the surface deeper within the mask, and therefore the mask shielded some virus from UV-C radiation. Rathnasinghe et al. examined total viral viability throughout the mask: they incubated squares of N95 mask material (3M 8211) in media spiked with SARS-CoV-2 before exposing them to varying doses of UV-C. Viral viability was measured after decontamination, and fit as a function of UV-C dose to a single exponential curve (73) . However, inspection of their data reveals that the time resolution of their experiment is insufficient to resolve the UV-C dosedependent inactivation kinetics. Moreover, the 3M 8211 N95 mask they used has a release valve, which is generally considered an exclusion criterion for use of UV-C decontamination. Using a similar method, Ludwig-Begall et al. found that doses of 2.6 J/cm 2 and 5.2 J/cm 2 , applied to a surgical mask and a KN95 respirator, respectively, yielded a >3 log-order reduction in viable porcine respiratory coronavirus. (71) This result suggests that UVGI is broadly effective to decontaminate disposable masks and respirators, but further work is needed to ensure that filtration is unaffected and to determine if the standard dose of 1 J/cm 2 is sufficient for decontamination. On the regulatory side, a nonbinding recommendation issued by the FDA contained three tiers for N95 respirator decontamination (82) . The highest level is recommended for decontamination of surgical masks for single-or multiple-users and includes a 6-log reduction of highly resistant bacterial spores. The second tier is intended for single-users only and specifies a 6-log order reduction of non-enveloped viruses or vegetative bacteria. The third tier recommends 3-log order reduction of non-enveloped virus or vegetative bacteria, and it is intended for single-users only to supplement existing CDC reuse recommendations. One of the key problems with these guidelines is that they do not specify how the bioburden reduction should be measured, in particular, where in the mask should the test be performed. Is it sufficient to obtain the desired reduction for a test sample applied to the surface of the mask, or is the same degree of reduction required for a sampled applied to any of the internal layers of the multilayer structure of the N95 mask? We noted that the user-facing Shell layer of the 3M 8210 mask is most problematic due to its high degree of UV-C absorption. In a single-user setting, the main aim is to decontaminate any virus that became trapped in the middle layers of the mask during use. Several strategies have been used to decontaminate N95 masks during the COVID-19 pandemic, most of which are being developed for large-scale applications. Here we review the efficacy of UV-C decontamination for N95s, considering factors such as UV transmittance to different layers of the mask, viral sensitivity to UV-C, and potential photodegradation of masks. We also describe the use a UV crosslinker box commonly found in molecular biology laboratories as a practical, point-of-use method for small-scale rapid UV-C decontamination of N95 masks. Such devices assure that a consistent dose of UV-C is applied to the masks, enabling reliable decontamination and repeated reuse without substantial mask photodegradation. Mass production of similar custom low-cost devices could be a cost-effective way of empowering frontline workers, and potentially the general public, to decontaminate masks even if they lack access to a large hospital-based decontamination facility. Kubelka theory (83, 84) to include the contributions of diffuse reflectance on the light distribution within the multilayer structure of the N95 mask. [ Table 1 ] Table 1 shows the values of the absorption and scattering coefficients, μ a and μ s , for the different layers of the 3M 8210 mask. The authors used the terms Outer layer for the Coverweb, Filter for the combined layers Filter 1 and Filter 2, and Inner layer for the Shell. However, they did not determine the thickness (d) for each mask layer and set it to some rather arbitrary values in their calculations of μ a and μ s . Therefore, these parameters have to be adjusted to be used with the layer thicknesses we measured for our masks. We calculate the dimensionless ratio with for the scattering power, P, using our experimental values for the transmittance T. The scattering power scales with the layer thickness d in the case of a homogeneous layer with the scattering coefficient μ s : We obtain the scattering coefficient by inverting Eq. 17: The absorption coefficient can now be calculated as: The reflectance, R, of a layer with non-reflecting backing is calculated as: The combination of two layers, 1 and 2, results in a combined transmittance, T 1,2 , and reflectance, R 1,2 , given by (84): (21) and with the transmittances T 1 and T 2 and the reflectances R 1 and R 2 of both layers measured in one direction following the order of the layers 1 and 2. The expressions also use the reflectance of layer 1 in reverse direction as indicated with the roman numeral index, R I . Note that the reflectances from the front (R 1 ) and back (R I ) of a homogeneous layer are identical, but when they are not for stacks of different materials. We use Eqns. 21 and 22 to calculate the transmittance and reflectance of the combined Filter 1 and Filter 2 (see Table 1 ) for comparison with the data for the Filter layer from Lilge et al. (70) . We are interested in the total amount of light present in the interior of the mask. At the interface of two layers, 1 and 2, the fraction T 1 of light transmitted through layer 1 hits the layer 2, which reflects the portion T 1 R 2 . The portion T 1 R 2 hits the back of layer 1, which reflects the portion T 1 R 2 R I and so on. The total fraction of the light at the interface of layers 1 and 2 can be obtained from: The generalization of Eqns. 21-23 from two layers to n layers is given by: To calculate the light distribution within one layer, we split it in two parts a and b with thicknesses I = i and K = 1 − i calculate the transmittance and reflectance of the sublayers using Eqns. 15, 17 and 20: The resulting layers can be used for Eqns. 24 to 25 to calculate the transmittance, T 1,2,3,…n , and reflectance, R 1,2,3,…n , and any of the inter-layer total light fractions, Total i,j , for the multilayer system. Inversion of the order of layers yields the relevant equations for the illumination from the other side of the stack, T n,n-1,…1 , R n,n-1,…1 and Total j,i . The position d within the multilayer structure can be calculated as = i , + i U , + U + i `, or + U + `+ i k , respectively. The local UV-C dosage, D(d), between layers i and j can be calculated analogous to Eq. 9 from the surface exposure in the forward direction (6) and the surface exposure in reverse direction (6 1 ) and the depth-dependent transmittances: 6 = 6 \7G] , + 6 1 \7G] , Critical Supply Shortages -The Need for Ventilators and Personal Protective Equipment during the Covid-19 Pandemic Modes of transmission of virus causing COVID-19: implications for IPC precaution recommendations Can N95 Respirators Be Reused after Disinfection? How Many Times Filtering Facepiece Respirator for Use by the General Public in Public Health Medical Emergencies -Class II Special Controls Guidance for Industry and FDA Staff Potential demand for respirators and surgical masks during a hypothetical influenza pandemic in the United States Enforcement Policy for Face Masks and Respirators During the Coronavirus Disease (COVID-19) Public Health Emergency (Revised) Guidance for Industry and Food and Drug Administration Staff Decontamination and Reuse of Filtering Facepiece Respirators using Contingency and Crisis Capacity Strategies Recommended Guidance for Extended Use and Limited Reuse of N95 Filtering Facepiece Respirators in Healthcare Settings Retrieved 5/30 Extended use or reuse of N95 respirators during COVID-19 pandemic: An overview of national regulatory authority recommendations The effect of soil accumulation on multiple decontamination processing of N95 filtering facepiece respirator coupons using physical methods Aerosol Loading Performance of Electret Filter Media A pandemic influenza preparedness study: use of energetic methods to decontaminate filtering facepiece respirators contaminated with H1N1 aerosols and droplets Ultraviolet germicidal irradiation of influenza-contaminated N95 filtering facepiece respirators ARA Research to Mitigate a Shortage of Respiratory Protection Devices During Public Health Emergencies N95 Filtering Facepiece Respirator Ultraviolet Germicidal Irradiation (UVGI) Process for Decontamination and Reuse Institution of a Novel Process for N95 Respirator Disinfection with Vaporized Hydrogen Peroxide in the Setting of the COVID-19 Pandemic at a Large Academic Medical Center A Scalable Method of Applying Heat and Humidity for Decontamination of N95 Respirators During the COVID-19 Crisis Methods for measuring and correcting the absorption spectrum of scattering suspensions Comparison of UV-Induced Inactivation and RNA Damage in MS2 Phage across the Germicidal UV Spectrum Inactivation of SARS coronavirus by means of povidone-iodine, physical conditions, and chemical reagents Inactivation of SARS coronavirus by means of povidone-iodine, physical conditions and chemical reagents A Genomic Model for the Prediction of Ultraviolet Inactivation Rate Constants for RNA and DNA Viruses Characterization of UVC light sensitivity of vaccinia virus Predicted inactivation of viruses of relevance to biodefense by solar radiation On the Interpretation of Multi-Hit Survival Curves Thickness Dependence of Optical Transmittance of Transparent Wood: Chemical Modification Effects A method to determine the available UV-C dose for the decontamination of filtering facepiece respirators Inactivation of the coronavirus that induces severe acute respiratory syndrome, SARS-CoV Resistance of Berne virus to physical and chemical treatment Effect of ultraviolet germicidal irradiation on viral aerosols Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles Filter performance of n99 and n95 facepiece respirators against viruses and ultrafine particles Viable viral efficiency of N95 and P100 respirator filters at constant and cyclic flow Development of a test system to apply virus-containing particles to filtering facepiece respirators for the evaluation of decontamination procedures Performance evaluation of filtering facepiece respirators using virus aerosols Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals Recognition of aerosol transmission of infectious agents: a commentary Reaerosolization of MS2 Bacteriophage from an N95 Filtering Facepiece Respirator by Simulated Coughing Performance of N95 respirators: Reaerosolization of bacteria and solid particles A Genomic Model for Predicting the Ultraviolet Susceptibility of Viruses and Bacteria Stability of SARS coronavirus in human specimens and environment and its sensitivity to heating and UV irradiation Induction of caspase-dependent apoptosis in cultured rat oligodendrocytes by murine coronavirus is mediated during cell entry and does not require virus replication Assessment of N95 respirator decontamination and re-use for SARS-CoV-2. medRxiv Systematic assembly of a fulllength infectious cDNA of mouse hepatitis virus strain A59 A new coronavirus associated with human respiratory disease in China Transcriptional and Translational Landscape of Equine Torovirus Vapor H 2 O 2 sterilization as a decontamination method for the reuse of N95 respirators in the COVID-19 emergency Homegrown Ultraviolet Germicidal Irradiation for Hospital-Based N95 Decontamination during the COVID-19 Pandemic Ultraviolet germicidal irradiation: Possible method for respirator disinfection to facilitate reuse during the COVID-19 pandemic UV Sterilization of Personal Protective Equipment with Idle Laboratory Biosafety Cabinets During the Covid-19 Pandemic UV light dosage distribution over irregular respirator surfaces. Methods and implications for safety Photo-oxidation of Polypropylene Fibers Exposed to Short Wavelength UV Radiations Photodegradation of partially oriented and drawn polypropylene filaments Polymer weathering: Photo-oxidation Surface characterization of photodegraded poly(ethylene terephthalate). The effect of ultraviolet absorbers Quantitative Investigation of the Photodegradation of Polyethylene Terephthalate Film by Friction Force Microscopy, Contact-Angle Goniometry, and X-ray Photoelectron Spectroscopy Effects of Ultraviolet Germicidal Irradiation (UVGI) on N95 Respirator Filtration Performance and Structural Integrity Effect of various decontamination procedures on disposable N95 mask integrity and SARS-CoV-2 infectivity. medRxiv:2020 Is the fit of N95 facial masks effected by disinfection? A study of heat and UV disinfection methods using the OSHA protocol fit test Technical Bulletin -Decontamination of 3M Filtering Facepiece Respirators, such as N95 Respirators Impact of three biological decontamination methods on filtering facepiece respirator fit, odor, comfort, and donning ease Global rise in human infectious disease outbreaks FDA. 2020. FAQs on Shortages of Surgical Masks and Gowns During the COVID-19 Principles and Practice of SARS-CoV-2 Decontamination of N95 Masks with UV-C. medRxiv:2020 UV-C irradiation is highly effective in inactivating and inhibiting SARS-CoV-2 replication Rapid inactivation of SARS-CoV-2 with LED irradiation of visible spectrum wavelenghts. medRxiv:2020 Viruses such as SARS-CoV-2 can be partially shielded from UV radiation when in particles generated by sneezing or coughing: Numerical simulations. medRxiv:2020 Practical considerations for Ultraviolet-C radiation mediated decontamination of N95 respirator against SARS-CoV-2 virus Scott, and I. Charnas. 2020. UV-C Tower for point-of-care decontamination of filtering facepiece respirators Light propagation within N95 filtered face respirators: A simulation study for UVC decontamination The use of germicidal ultraviolet light, vaporised hydrogen peroxide and dry heat to decontaminate face masks and filtering respirators contaminated with a SARS-CoV-2 surrogate virus Exploring options for reprocessing of N95 Filtering Facepiece Respirators (N95-FFRs) amidst COVID-19 pandemic: a systematic review Scalable, effective, and rapid decontamination of SARS-CoV-2 contaminated N95 respirators using germicidal ultra-violet C (UVC) irradiation device A systematic review of mask disinfection and reuse for SARS-CoV-2 Decontamination of N95 masks against coronavirus: a scoping review. medRxiv:2020 Modeling-based UV-C decontamination of N95 masks optimized to avoid undertreatment Rapid and complete inactivation of SARS-CoV-2 by ultraviolet-C irradiation UV-C decontamination for N95 emergency reuse: Quantitative dose validation with photochromic indicators. medRxiv:2020 UV Decontamination of Personal Protective Equipment with Idle Laboratory Biosafety Cabinets During the The use of germicidal ultraviolet light, vaporised hydrogen peroxide and dry heat to decontaminate face masks and filtering respirators contaminated with an infectious norovirus 2020. The effect of ultraviolet C radiation against different N95 respirators inoculated with SARS-CoV-2 Recommendations for Sponsors Requesting EUAs for Decontamination and Bioburden Reduction Systems for Surgical Masks and Respirators During the Coronavirus Disease 2019 (COVID-19) Public Health Emergency -Guidance for Industry and Food and Drug Administration Staff New Contributions to the Optics of Intensely Light-Scattering Materials .1 New Contributions to the Optics of Intensely Light-Scattering Materials .2. Nonhomogeneous Layers We thank the Rockefeller University laboratories of Drs. Modeling the light distribution in a multilayer structure accounting for diffuse reflectance. Our original model describes the depth-dependent transmittance and optical thickness as the integral of a depth-dependent attenuation coefficient (Eq. 3). We could not discriminate the relative contributions from absorbance and scattering to this attenuation coefficient, since we did not have a setup to measure reflectivity. Lilge et al. studied the light distribution within N95 masks provides data for the relative strength of absorbance and scattering coefficients of the materials in the 3M 8210 mask from integrating sphere reflectance and transmittance measurements (70) . Here we extend our model using the