key: cord-0919458-b1u2hffm authors: Fahrenfeld, N. L.; Morales Medina, William R.; D'Elia, Stephanie; Modica, Maureen; Ruiz, Alejandro; McLane, Mark title: Comparison of residential dormitory COVID-19 monitoring via weekly saliva testing and sewage monitoring date: 2021-11-24 journal: Sci Total Environ DOI: 10.1016/j.scitotenv.2021.151947 sha: 4fd8819f90126a7438d4b3c5a9d2dcddb2b85f8b doc_id: 919458 cord_uid: b1u2hffm Wastewater surveillance has been used as tool for outbreak detection for COVID-19 particularly where there was not capability in place for routine and robust individual testing. Given clinical reports that earlier detection is possible following infection from throat/nasal samples compared to fecal samples for COVID-19 patients, the utility of wastewater testing where robust individual testing is possible is less clear. The objective of this study was to compare the results of weekly required COVID-19 saliva tests to weekly wastewater monitoring for residential buildings (i.e., dormitories) located across three college campuses capturing wastewater from 80 to 441 occupants per sampling location. Sampling occurred during the spring semester of the 2021 academic year which captured the third wave of SARS-CoV-2 cases in the study region. Comparison of the saliva and wastewater testing results indicated that the wastewater SARS-CoV-2 concentrations had a strong linear correlation with the previous week's percentage of positive saliva test results and a weak linear correlation with the saliva testing results surrounding the wastewater sampling (four days before and 3 days after). Given that no correlation was observed between the wastewater and the saliva testing from the following week, the weekly saliva testing captured spikes in COVID-19 cases earlier than the weekly wastewater sampling. Interestingly, the N1 gene copy was observed in buildings on all campuses, but N2 was observed in wastewater on only one of the campuses. N1 and N2 were also observed in sewer biofilm. The campus-specific challenges associated with implementation of wastewater surveillance are discussed. Overall, these results can help inform design of surveillance for early detection of SARS-CoV-2 in residential settings informing mitigation strategies to slow or prevent the spread of the virus among residents in congregate living. SARS-CoV-2 is shed in the feces of COVID-19 patients including asymptomatic individuals, making it a suitable target for wastewater-based monitoring. Reports of SARS-CoV-2 detection have been made in wastewater from around the world (Ahmed et al., 2020; Kitajima et al., 2020; Kumar et al., 2020; La Rosa et al., 2020; Medema et al., 2020) and build upon longer history of using wastewater monitoring for viral disease and vaccinations (Xagoraraki and O'Brien, 2020) . Of particular interest during the COVID-19 pandemic is the design of monitoring programs for congregate living and university campuses, where transmission rates may be high due to shared living, bathing, and dining spaces and the highly social nature of the population. Universities have implemented a range of techniques for monitoring including daily symptom reporting, wellness checks, required individual testing prior to or upon campus move-in, movement tracking, and contact tracing, among other measures (Table 1) . Many campuses implemented wastewater surveillance as a part of their monitoring programs and several campus representatives surveyed express unequivocally that the wastewater monitoring was "worth the efforts," (Harris-Lovett et al., 2021) . asymptomatic testing weekly (Bivins and Bibby, 2021) to every two weeks (Scott et al., 2021) . The outcome of a US nationwide survey effort noted that the need remains to understand how to optimize wastewater monitoring with clinical testing to improve outcomes, including early detection and mitigation (Harris-Lovett et al., 2021) . Where wastewater surveillance was more frequent and individual testing less frequent, dormitory wastewater surveillance was reported as predictive of cases, asymptomatic cases, and capturing outbreaks early (Betancourt et al., 2021; Gibas et al., 2021; Karthikeyan et al.; Scott et al., 2021) and as a lagging indicator when individual testing was more frequent (Bivins and Bibby, 2021) . Results from hospitalized patients indicate that viral shedding in fecal matter occurs ~3-7 days after a positive PCR test can be obtained from a nasal swab and that shedding in feces could continue for 6-10 days following a negative nasal swab (Foladori et al., 2020) . Therefore, where regular individual testing of a population including asymptomatic individuals is implemented, one would expect wastewater surveillance to be a lagging indicator and where individual testing is not routinely implemented or testing compliance is insufficient then wastewater surveillance would be a leading indicator. The objective of this study was to compare the results of COVID-19 saliva tests to wastewater monitoring for residential buildings on college campuses. To do this, weekly wastewater samples were collected from access sites within or outside of the buildings and the SARS-CoV-2 N1 and N2 gene copies were quantified with qPCR. Wastewater data were compared to the required weekly saliva test results reported by building residents to the college. Results presented provide insight into the different monitoring approaches for capturing viral disease outbreak. J o u r n a l P r e -p r o o f Journal Pre-proof Table 1 . Literature review for SARS-CoV-2 monitoring studies of dormitory wastewater (WW) including location, frequency of wastewater sample collection, description of individual testing, other health data collected, SARS-CoV-2 genes targeted, and normalization efforts for SARS-CoV-2 gene copies. Location ( A SARS-CoV-2 wastewater monitoring study was performed at a large state university in winter 2020 through spring 2021. The university has an enrollment of >60,000 students across three campuses (C1, C2, and C3 with 10%, 19%, and 71% of enrollment, respectively) that are primarily located in urban and suburban areas. During a typical semester, 57% of students live off-campus and during the study period campus housing was filled at <20% regular capacity. On-campus housing availability was limited during the study period in efforts to protect health and safety of the student population. Classes were taught remotely with the exception of practicum and laboratories that required in-person work. Both undergraduate and graduate students were living in university housing during the study period, many of the former were student athletes. There were a total of 3,523 total residents, of which this pilot captured wastewater from 1,414 residents (Table 2) . Several pandemic-specific guidelines were instituted for residents including: social distancing, limitations on public gatherings, wearing a face covering in public spaces, diagnostic and Vaccines became available to the community across the study period, regardless of vaccine status university housing residents were required to complete weekly testing (this policy changed after the study period). This study reviewed by the Rutgers Institutional Review Board as secondary research and determined to be exempt following review. Wastewater sampling sites were selected on each campus based on the availability of sampling access locations that only captured residents' wastewater (e.g., multiuse buildings with housing and classrooms, stores, or restaurants were not included The 24-hour composite samples (1 L) were collected using WS700 automatic portable samplers (Model WS700, Xylem, Rye Brook, NY, USA). At select sampling locations and dates, the automatic sampler did not collect large enough sample volumes for processing and in this situation, grab samples were collected (N=5 grab / 140 samples total). After collection, the samples were stored at 4°C and transported to the lab in a cooler with ice. Upon arrival at the lab, the wastewater samples were pasteurized in a water bath at 55°C for one hour or in an incubator at 55°C for 90 min to inactivate viral particles (Wu et al., 2020) . Immediately after J o u r n a l P r e -p r o o f pasteurization, the samples were processed for concentration and precipitation of viral particles, as described below. For quality assurance, field blanks consisting of deionized water were included for each week during sampling, rotating between the campuses. A total of 18 field blanks were processed during the study period in parallel with the wastewater samples. Grab biofilm samples were collected on April 27, 2021 in triplicate, from four of the locations where the wastewater samples were collected (C1a, C3a, C3b, C3c-1). Samples were collected by attaching a sterile cotton swab to a ~ 9 m long PVC pipe to reach and scrape the biofilm formed in the bottom of the manholes. Then, the tip of the cotton swab containing the sample was placed in a 2 mL plastic O-ring tube and stored in a cooler with ice for transportation. Upon arrival to the lab, the tubes were stored at -80°C. J o u r n a l P r e -p r o o f Concentration and precipitation of viral particles from wastewater was done following a polyethylene glycol (PEG) precipitation method (Wu et al., 2020) . Briefly, 200 mL of wastewater was filtered through a 0.22 µm mixed cellulose esters (MCE) membrane (Millipore Sigma, St. Louis, MO). The filtrate was then precipitated with polyethylene glycol 8000 (8% wt/vol) and NaCl (0.3 M). The samples were shaken by hand and incubated at room temperature for ~15 min, until the chemicals were dissolved. The sample solution (200 mL of filtrate with PEG and NaCl) was centrifuged for 2 hours at 12000 × g immediately or after holding overnight at 4°C. Then, ~ 150 mL of supernatant of each falcon tube was discarded and the remaining 50 mL was vortexed and transferred to 50 mL falcon tube. The 50 mL falcon tube was then centrifuged at 12000 × g for 45 min or until a pellet was visible. The supernatant was discarded and the pellet was used for total RNA extraction. Total RNA from the wastewater samples were analyzed by reverse transcription quantitative PCR (RT-qPCR) to detect and quantify the SARS-CoV-2 N1 and N2 and pepper mottle virus (PMMoV) . (Haramoto et al., 2013) gene copies in the samples. The reverse transcription and PCR reactions were performed using the iTaq Universal Probes One-step kit (Bio-Rad, catalog no. 1725141) and the US CDC N1 and N2 primer-probe (Table A1, Table A1 for raw wastewater and RNA extracts. The limit of quantitation (LOQ) for N1 and N2 in the wastewater samples was 1.25 gene copies/mL as determined based on the lowest qPCR standard. The limit of detection (LOD) was the same as the LOQ for N1 and N2, as positive control dilution lower than 10 1 copies/mL resulted in no detection for the qPCR. Agarose gel electrophoresis was used to confirm the presence of amplicons with the correct insert length and detection below the LOQ/LOD. For the PMMoV primer-probe set, PCR conditions included a reverse transcription cycle of 10 mins at 50°C, a denaturing step of 10 mins at 95°C, followed by 45 cycles of 10 sec at 95°C and 1 min at 52°C and 1 min at 72°C. Lyophilized virus served as the positive control for PMMoV (agida, Elkhart, IN) which was resuspended in the PM1 solution from RNA extraction kit, as described above, and RNA was extracted following the manufacturer's instructions. The concentration of RNA in the extracts was measured via Nanodrop and the equation described by Rosario et al. (2009) Conductivity was measured using a calibrated multimeter (Orion Star A329, Thermo Scientific) and pH was measured using a calibrated Oakton pH 700 (Oakton Instruments) in the laboratory. Of the 140 wastewater samples collected, four samples had insufficient volume for analysis. Statistical tests were performed in R (www.r-project.org). Pearson correlations were tested between the percentage of positive saliva tests (number of positive tests/number of building residents) for the seven days prior, the days surrounding (i.e., 4 days before and 3 days after), or the seven days after the wastewater sample collection and the gene copy concentrations observed in the wastewater. Pearson correlations were tested also between PMMoV normalized N1 and N2 data and the percentage of positive saliva tests. To compare the observed concentrations of N1 and N2 gene fragments in wastewater, a paired Wilcoxon Rank Sum test was performed. Pearson correlations were also tested between the concentrations of the two gene fragments. Gene copy concentrations across time were compared between campuses using a paired Wilcoxon Rank Sum test. Average gene copy concentrations were compared using a Kruskal Wallis with a post hoc pairwise t-test with a Bonferroni correction for multiple comparisons. J o u r n a l P r e -p r o o f SARS-CoV-2 N1 and N2 genes were each detected in 69.2-94.7% and 0-50%, respectively, of the wastewater collected at each sampling location. N1 concentrations, when detected and quantifiable, were 36 ± 204 gene copies/mL with a maximum of 1800 copies/mL. The concentrations detected were generally within the ranges we observed in municipal wastewater collected at the treatment plant intakes (data not shown). The maximum N1 concentration observed in university residential wastewater (3.25-log10 copies/mL) was an order of magnitude higher than the peak N1 concentration we observed in municipal wastewater (data not shown) and within the ranges reported by other dormitory studies that reported gene copy concentrations in wastewater (Betancourt et al., 2021; Scott et al., 2021) . The date of peak wastewater concentration for N1 varied by sampling location with maximums occurring on January 13, January 27, February 10, or February 24 (Fig. 1) . These peak concentrations were all from composite samples (N1 was not detected in two of the grab samples, and ranged from 0.28) with the only site to site significant difference between conductivity between C2b and C1a (pairwise t-test, p=0.047, Fig. A3 ). Collection of total suspended solids and chemical oxygen demand data were beyond the scope of this project; however, these data were collected prior to the study period at select sampling locations during a period where the N1 and N2 gene were below detection in all wastewater samples collected (Table A2 ). Field sewer biofilm samples were collected to screen for the potential of SARS-CoV-2 RNA to accumulate in sewer biofilms, which if sloughed and containing the target gene copies could impact wastewater concentrations. qPCR analysis of the N1 and N2 viral nucleocapsid gene fragments resulted in detection below the limit of quantitation (LOQ) in all the biofilm samples. PMMoV concentrations in the biofilm ranged from 3.3 to 4.6-log 10 gene copies per swab (Table A3 ). The low abundance of SARS-CoV-2 RNA in the biofilm samples was not surprising because when the samples were collected (April 27, 2021), the N1 gene qPCR signal in the wastewater samples collected from these locations was below the LOQ in two of the sites (C3a and C1a) and ranged between 0.01 and 10 copies/mL in C3b and C3c-1 (Fig. 1 ). In addition, the signal obtained from the N2 gene in wastewater samples collected on April 28, 2021 was below LOQ in all the samples except for C3c-1 (Fig A1) . Previous studies in our lab showed that accumulation of SARS-CoV-2 RNA in simulated biofilm samples at peak concentrations observed had a ~1:1000 ratio for N2 to PMMoV gene copies (Morales Medina et al., in review). A total of 268 positive saliva tests were recorded across the study sites ranging from five (for a site with 80 residents) to 142 (for a site with 414 residents) total across the spring semester sampling campaign. The maximum reported positive tests in a day for a given sampling site ranged from one to 30 and the maximum percentage of building residents with a positive test on a given day ranged from 0.04 (mixed graduate and undergraduate population) to 7.2% (undergraduate students, only). The date of peak percentage of positive tests did not coincide across sites, but were observed during January and February (Fig. A2) . While the testing of the residents across the study period was robust in comparison to many other campuses that required no asymptomatic to less frequent asymptomatic testing (Table 1) , the testing strategy was designed to capture asymptomatic cases and residents experiencing COVID-19 symptoms were asked to quarantine rather than complete a test, these results would be expected to represent an underestimate of total cases if those with symptomatic cases followed these instructions. The number of tests completed each week varied across the study period. For example, for all students submitting samples on Campus 3, the number of weekly tests completed by students ranged from ~1,600 to >4,900 (including those living in residence hall and those working on campus) with an average of ~3,300 per week. Therefore, percent positive tests were calculated based on the number of residents for a given sampling site and used for comparison to the wastewater data, presented below. Data were collected by the university on negative and inclusive tests and reported on a weekly basis. For Campus 3, an average of 1.51 ± 0.01% of tests were positive and 0.30 ± 0.13% of tests were inconclusive each week across the study period. For paired weekly totals, the inconclusive tests represented 34 ± 30% of the total positive cases reported, and thus represented a potentially significant source of error. Correlations were tested between the wastewater N1 or N2 gene copy concentrations and the saliva test percent positive test results (100 × number of positive samples / number of residents) for a given sampling site (Fig. 3) . Moderate correlations were observed between the N1 gene and the positive saliva tests collected during the seven days before the wastewater collection Table A3 . Given the strongest correlation was observed with the wastewater N1 gene concentrations and the previous week's saliva test results and no correlation was observed with the following week's saliva test results, the wastewater data here represent a lagging indicator of COVID-19 infections in the buildings tested. The possibility of fecal shedding into the dorm sewers continued for 48 to 96 hrs after a positive saliva test (including both the time to receive results and be relocated). And the positive cases were not-recounted, as re-testing did not occur for 90 d following the initial positive saliva test. This is similar to results reported for a study performed during a campus vaccination campaign that included required weekly testing for asymptomatic persons and observed correlations between wastewater and rolling 7-day average cases (Bivins and Bibby, 2021) . While this may seem in contrast to reports of wastewater serving as a leading indicator of SARS-CoV-2 infections (Betancourt et al., 2021; Gibas et al., 2021; Karthikeyan et al.) , less frequent individual testing (sampling less frequently than one sample per week) was J o u r n a l P r e -p r o o f implemented in the sewer catchment for those studies. Thus, when individual testing is not robust, weekly or more frequent wastewater detection may still serve as a leading indicator of outbreaks. The seven-day windows of COVID-19 cases were selected for these comparisons because residents submitted their saliva tests at least seven days apart, assuming testing compliance. Thus, seven-day windows would capture at most one sample per resident (unless involved in contact tracing). The stronger correlations observed for the previous week's compared to surrounding week's saliva tests may be due to the reported delay in clinical patients between a positive saliva test and the onset of fecal shedding (Foladori et al., 2021) . Other researchers have compared clinical testing results or hospitalizations on varying time scales to wastewater SARS-CoV-2 observations for in-sewer or sewershed-wide studies ranging from daily cases (Ai et al., 2021) , 3 to 7 day average or cumulative cases (Agrawal et al., 2021; Galani et al., 2022; Giraud-Billoud et al., 2021; Koureas et al., 2021) , and 10 to 20 day cumulative cases (Barrios et al., 2021) . The correlations when observed could have been improved if more data were available to help normalize the gene copy concentrations observed in the wastewater. Various normalization schemes have been suggested and tested to date for SARS-CoV-2 including correcting for flow, variations in water quality, and use of other biological markers to improve understanding of fecal loading in a given sample (Betancourt et al., 2021; Feng et al., 2021) . Here, flow meters were not installed at the sampling locations, therefore wastewater flow during the composite sampling period is not known. Correlations tested with the PMMoV normalized N1 and N2 gene copy observations. The PMMoV concentrations observed were on average 3.5 ± 1.1 log10-copies/mL within the ranges reported for untreated wastewater (~10 2 -10 7 gene copies/mL) (Kitajima et al., 2018) (Fig. A4 ). Correlations were not observed for the PMMoV normalized N1 data compared J o u r n a l P r e -p r o o f to the saliva test results. The PMMoV normalized N2 data produced similar correlations to the saliva test results as the non-normalized N2 data (Table A5 , Fig. A5 ). Thus, as reported by others at the municipal scale (Feng et al., 2021) , normalizing SARS-CoV-2 to PMMoV did not improve the correlations observed with saliva testing results in this study. Likewise, normalizing the SARS-CoV-2 nucleocapsid gene concentrations to pH or conductivity did not improve the correlations between saliva test results (Table A6, Given the short travel distance between the point of entry and sampling location for these data, decay of SARS-CoV-2 target genes is unlikely to be a major contributing factor, nor dilution due J o u r n a l P r e -p r o o f to infiltration or inflow to the correlations, or lack thereof, observed here. We have observed that SARS-CoV-2 can accumulate in simulated sewer biofilms during periods of high and low cases numbers (Morales Medina et al., in prep) . Here, biofilm samples were collected late in the study period (Table A3 ) and low abundance of SARS-CoV-2 RNA was observed in the biofilm samples. This observation was not surprising because when the samples were collected (April 27, 2021), the N1 gene qPCR signal in the wastewater samples collected from these locations was below the LOQ in two of the sites (C3a and C1a) and ranged between 0.01 and 10 copies/mL in C3b and C3c-1 (Fig. 1 ). In addition, the signal obtained from the N2 gene in wastewater samples collected on April 27, 2021 was below LOQ in all the samples except for C3c-1 which was 1 copy/mL ( Fig A1) . Therefore, the potential for sloughing of biofilms containing viral gene copies to impact the observations here is not clear. Limitations of the wastewater sampling pilot implemented here were noted including the sampling locations and frequency. The university housing for Campus 3 has over 100 buildings, and while not all were occupied during the study period, the labor and supplies including installation of sampling infrastructure was a limitation here due to uncertainty with the methods analyzed when the targets were detected, could provide more precise information needed for decision making (i.e., whole building quarantine or individual resident re-testing) which with this sampling scheme would impact potentially more students than needed. For some housing units on the campuses studied in this study, it was not possible to sample residential wastewater separately from the other building uses given the sewage collection systems were not designed with this purpose in mind. Some other researchers sampled early morning in efforts capture building residents rather than visitors or non-resident employees (Betancourt et al., 2021) . Otherwise, a retrofit would be required for current buildings and future plumbing design may wish to take WBE considerations into account when designing collection systems in multi-use buildings. The sampling design for this pilot study involved weekly sampling. The day of the week for sampling was selected for multiple reasons. Sampling Tuesday or Wednesday allowed for staff that work weekdays to set up and collect samples during regular work hours and for the lab to report data during regular business hours, as data were available on Friday afternoons for reporting. Sampling on the weekend was also avoided given the presumption that use patterns could vary on the two days without regular classes scheduled. It is possible that the correlations presented here would be different if more frequent wastewater sampling was performed, as several others have done (Table 1) . J o u r n a l P r e -p r o o f Weekly saliva testing resulted in earlier detection of COVID-19 cases in dormitory populations as compared to weekly wastewater surveillance on the campuses studied. These results in combination with low case rates and vaccine mandates all contributed to decision among the administrators in the present study to pause the wastewater surveillance program on the campuses studied. When using these results for design of campus surveillance, it would be advisable to consider the testing compliance rates when determining if the results of our study would be repeated. Here, a small population was present on campus and the study was performed before and during the time vaccines began to be available to the study population. Comparison of these results to other study designs as well as other considerations including cost and practicality (Harris-Lovett et al., 2021) will likely inform future monitoring study designs. The results presented highlight the need for further study to understand whether the lack of N2 detection on C1 and C2 was due to different SARS-CoV-2 variants present; application of sequencing on preserved samples may provide insight. The observation of N1 and N2 in the C3 biofilm samples also highlights the need for further understanding of this sewer matrix, for which a separate study was performed (Morales Medina et al., in review) indicating SARS-CoV-2 can accumulate in sewer biofilms during periods of high COVID-19 cases. Fig. 1 Log10 transformed N1 gene copy concentrations versus sampling date for each sampling location. Error bars represent the standard deviation among technical replicates (n=3) and colors correspond to the different campuses sampled. Log10 transformed concentration of N2 gene copies versus N1 gene copies with colors corresponding to different sampling sites. Red line represents the linear regression and shaded area the 95% confidence interval. Non-detects are shown intersecting with the respective axes. Fig. 3 Concentrations of N1 and N2 gene copies versus the percent positive tests (number of positives per sampling location / total residents per location) for the 7 days before the wastewater (WW) collection. Data points are color coded by site, shape corresponds to the campus. Error bars represent standard deviation of technical replicates (N=3). J o u r n a l P r e -p r o o f Long-term monitoring of SARS-CoV-2 RNA in wastewater of the Frankfurt metropolitan area in Southern Germany First confirmed detection of SARS-CoV-2 in untreated wastewater in Australia: A proof of concept for the wastewater surveillance of COVID-19 in the community Wastewater SARS-CoV-2 monitoring as a community-level COVID-19 trend tracker and variants in Ohio, United States Dynamics of SARS-CoV-2 in wastewater in three districts of the Buenos Aires metropolitan region, Argentina, throughout nine months of surveillance: A pilot study COVID-19 containment on a college campus via wastewater-based epidemiology, targeted clinical testing and an intervention Wastewater Surveillance during Mass COVID-19 Vaccination on a College Campus Development of wastewater pooled surveillance of SARS-CoV-2 from congregate living settings Evaluation of Sampling, Analysis, and Normalization Methods for SARS-CoV-2 Concentrations in Wastewater to Assess COVID-19 Burdens in Wisconsin Communities SARS-CoV-2 from faeces to wastewater treatment: What do we know? A review Lack of N2-gene amplification on the Cepheid Xpert Xpress SARS-CoV-2 assay and potential novel causative mutations: A case series from SARS-CoV-2 wastewater surveillance data can predict hospitalizations and ICU admissions Implementing building-level SARS-CoV-2 wastewater surveillance on a university campus Monitoring of SARS-CoV-2 RNA in wastewater as an epidemiological surveillance tool in Mendoza Occurrence of pepper mild mottle virus in drinking water sources in Japan Wastewater Surveillance for SARS-CoV-2 on College Campuses: Initial Efforts, Lessons Learned, and Research Needs Large-Scale Wastewater Surveillance and Automated Reporting System Enable Early Detection of Nearly 85% of COVID-19 Cases on a University Campus. mSystems SARS-CoV-2 in wastewater: State of the knowledge and research needs Pepper mild mottle virus as a water quality indicator Wastewater monitoring as a supplementary surveillance tool for capturing SARS-COV-2 community spread. A case study in two Greek municipalities First proof of the capability of wastewater surveillance for COVID-19 in India through detection of genetic material of SARS-CoV-2 First detection of SARS-CoV-2 in untreated wastewaters in Italy Presence of SARS-Coronavirus-2 RNA in Sewage and Correlation with Reported COVID-19 Prevalence in the Early Stage of the Epidemic in The Netherlands Pepper mild mottle virus as an indicator of fecal pollution Targeted wastewater surveillance of SARS-CoV-2 on a university campus for COVID-19 outbreak detection and mitigation SARS-CoV-2 Titers in Wastewater Are Higher than Expected from Clinically Confirmed Cases. mSystems 2020 Based Epidemiology for Early Detection of Viral Outbreaks SARS-CoV-2 samples may escape detection because of a single point mutation in the N gene. Euro surveillance : bulletin Europeen sur les maladies transmissibles CRediT roles: NLF: Conceptualization; Formal Analysis; Funding acquisition; Investigation WRMM: Data curation; Formal analysis; Funding acquisition; Investigation; Methodology; Writing -review & editing. SD: Data curation; Formal analysis; Investigation; Methodology; Writing -review & editing. MM: Conceptualization; Investigation; Methodology Writing -review & editing. MML: Conceptualization; Data curation Acknowledgements Thanks to David Schreiber for providing access to a biosafety cabinet for performing this work.