key: cord-0917577-rn9pkk52 authors: Michiwaki, Yuhei; Tanaka, Tatsuya; Wakamiya, Tomihiro; Tabei, Yusuke; Samura, Kazuhiro; Suehiro, Eiichi; Kawashima, Masatou title: Emergent carotid artery stenting following intravenous alteplase infusion after rapid negative diagnosis for COVID-19 by loop-mediated isothermal amplification assay: A case report date: 2020-10-09 journal: World Neurosurg DOI: 10.1016/j.wneu.2020.09.166 sha: 8f5b921dc9b7879b4a5a404c7603a75e966d87ea doc_id: 917577 cord_uid: rn9pkk52 Background During the coronavirus disease 2019 (COVID-19) pandemic, a rapid screening method for COVID-19 detection is needed to decide the appropriate strategy to treat stroke patients. In acute ischemic stroke treatment, the efficacy and safety of emergent carotid artery stenting (eCAS) for hyperacute ischemic stroke (hAIS) due to internal carotid artery stenosis (ICS) have not been sufficiently established. Case Description A 71-year-old man with hAIS caused by severe ICS was treated via intravenous alteplase infusion. The patient underwent screening for COVID-19 by the loop-mediated isothermal amplification (LAMP) assay shortly after arrival at our institution. The LAMP result was obtained within 90 minutes, during intravenous alteplase infusion, and turned out to be negative. The symptom of hemiplegia worsened during alteplase infusion, and he, therefore, underwent eCAS after administration of aspirin (200 mg). Recanalization was achieved successfully by eCAS, and dual antiplatelet therapy and argatroban were administrated following eCAS. Hemorrhagic complications or re-stenosis/occlusion of the carotid artery were not observed. He was discharged without neurological deficits 15 days following eCAS. Because of the rapid negative diagnosis for COVID-19 using the LAMP method, eCAS could be performed following standard procedures, along with infectious defense, without delay. Conclusions This case report suggests that eCAS for hAIS due to ICS following intravenous alteplase can be an effective treatment, along with appropriate antiplatelet medication and management in select patients. During the COVID-19 pandemic, the LAMP assay for COVID-19 detection might be a suitable diagnostic strategy preceding stroke treatment because of the rapid turnaround time. During the coronavirus disease 2019 (COVID-19) pandemic, a rapid screening method for COVID-19 detection is needed to decide the appropriate strategy to treat stroke patients. In acute ischemic stroke treatment, the efficacy and safety of emergent carotid artery stenting (eCAS) for hyperacute ischemic stroke (hAIS) due to internal carotid artery stenosis (ICS) have not been sufficiently established. A 71-year-old man with hAIS caused by severe ICS was treated via intravenous alteplase infusion. The patient underwent screening for COVID-19 by the loop-mediated isothermal amplification (LAMP) assay shortly after arrival at our institution. The LAMP result was obtained within 90 minutes, during intravenous alteplase infusion, and turned out to be negative. The symptom of hemiplegia worsened during alteplase infusion, and he, therefore, underwent eCAS after administration of aspirin (200 mg). Recanalization was achieved successfully by eCAS, and dual antiplatelet therapy and argatroban were administrated following eCAS. Hemorrhagic complications or re-stenosis/occlusion of the carotid artery were not observed. He was discharged without neurological deficits 15 days following eCAS. Because of the rapid negative diagnosis for COVID-19 using the LAMP method, eCAS could be performed following standard procedures, along with infectious defense, without delay. This case report suggests that eCAS for hAIS due to ICS following intravenous alteplase can be an effective treatment, along with appropriate antiplatelet medication and management in select patients. During the COVID-19 pandemic, the LAMP assay for COVID-19 detection might be a suitable diagnostic strategy preceding stroke treatment because of the rapid turnaround time. J o u r n a l P r e -p r o o f The coronavirus disease 2019 (COVID-19) pandemic has had a significant impact on treatment paradigms of all diseases. [1] [2] [3] [4] For instance, patients with acute ischemic stroke (AIS), who must be treated appropriately and promptly, should be screened for COVID-19 simultaneously. 5-7 Therefore, a rapid screening method for COVID-19 is needed to help decide the proper treatment strategy for stroke patients. Carotid artery stenting (CAS) is a standard treatment procedure for internal carotid artery stenosis (ICS) 8 ; however, the efficacy and safety of emergent CAS (eCAS) for hyperacute ischemic stroke (hAIS) due to ICS have not been sufficiently established. Herein, we aimed to report a case of hAIS due to severe ICS, which was successfully treated with eCAS following intravenous alteplase infusion. Moreover, the patient underwent screening for COVID-19 by the loop-mediated isothermal amplification (LAMP) method shortly after admission, and eCAS was performed using standard procedures without any further delay because the LAMP assay revealed a negative diagnosis for COVID-19 immediately before eCAS. This case report not only demonstrates the effectiveness of eCAS for treatment of hAIS, but also shows the value of using the LAMP assay for COVID-19 screening to enable prompt treatment of hAIS. J o u r n a l P r e -p r o o f A 71-year-old man was admitted to our institution due to sudden dysarthria and slight left hemiplegia in May 2020. He had a history of atrial fibrillation, hypertension, and diabetes mellitus, and had been receiving oral administration of dabigatran. Due to the COVID-19 pandemic, a nasopharyngeal swab specimen collected from the patient was examined using the LAMP assay immediately upon arrival according to the protocol of our institution. The duration from onset to admission was 75 minutes, and the score on the National Institutes of Health Stroke Scale (NIHSS) was 6/42. Computed tomography (CT) performed 15 minutes following admission showed a slight ischemic change at the right frontal lobe (Alberta Stroke Program Early Computed Tomography Score: 9). CT angiography demonstrated severe ICS and poor blood flow in the right intracranial internal carotid artery (ICA) ( Figure 1A , B). The patient was diagnosed with hAIS due to ICS and was then treated with intravenous alteplase (time from onset to infusion: 107 minutes; time from admission to infusion: 32 minutes). Magnetic resonance imaging (MRI) performed during intravenous alteplase infusion revealed sporadic infarction in the right cerebrum ( Figure 1C ). The symptoms of hemiplegia improved upon the initiation of intravenous alteplase infusion, but got worse again during the alteplase infusion. Thereafter, we decided to perform an eCAS following administration of aspirin (200 mg). As the LAMP assay revealed a negative diagnosis for COVID-19 during intravenous This case report highlights two important findings. First, eCAS following intravenous alteplase infusion for hAIS due to ICS was effective and safe in this patient. Second, the LAMP assay was a suitable screening tool for COVID-19 preceding stroke treatment because the results could be obtained rapidly. Intravenous alteplase has been proven to improve patient outcomes following hAIS, 9, 10 and endovascular thrombectomy has become the standard treatment for hAIS due to large vessel occlusion in the anterior circulation. [11] [12] [13] [14] [15] [16] However, the efficacy of eCAS for hAIS due to ICS has not been established. Since alteplase is a thrombolytic drug, it cannot be used to treat plaque-based atherosclerotic stenosis. Moreover, chronic atherosclerotic stenosis could not be removed easily by mechanical thrombectomy. Therefore, it seems reasonable to assume that eCAS can contribute to recanalization success in patients with hAIS due to ICS. In the present case, we decided to perform eCAS because the symptoms of hemiplegia worsened, despite intravenous alteplase infusion. While some studies have reported the efficacy and safety of eCAS, 17,18 most of them performed CAS within a few days to two weeks following the onset of AIS, and studies demonstrating successful eCAS for hAIS are rare. One of the reasons that the efficacy of eCAS has not been sufficiently ascertained is thought to be the risk of ICA occlusion caused by in-stent thrombosis due to the insufficient efficacy of antiplatelet agents administered J o u r n a l P r e -p r o o f before eCAS. Although administration of antiplatelet medication before elective CAS has been recommended, the ideal regimen of eCAS for hAIS has not been established. 19 High dose antiplatelet medication could decrease the risk of in-stent thrombosis; however, it may increase the risk of intracranial hemorrhage, particularly in patients who have undergone intravenous alteplase treatment. Deguchi et al. reported three cases of eCAS for hAIS immediately after intravenous alteplase treatment. 20 They administrated antiplatelet agents at the loading dose (cases 1 and 3: 300 mg clopidogrel + 200 mg aspirin; case 2: 300 mg clopidogrel) before eCAS; case 2 presented with an asymptomatic intracranial hemorrhage, and an ICA occlusion due to in-stent thrombosis occurred in case 1. In the present study, the patient was administrated 200 mg aspirin before eCAS, which was less than the dose used in a previous study. 20 The patient presented neither in-stent thrombosis nor hemorrhagic complications. Therefore, the dose of antiplatelet agents used or the postoperative management performed in this case might have been appropriate. Additionally, we used Carotid GuardWire and a Carotid Wallstent under PFC. One study has indicated that eCAS for AIS under PFC is effective and safe. 17 This case report provides evidence that could improve the management of eCAS cases following intravenous alteplase infusion. With the recent development of endovascular treatment, effective and safe therapeutic or management strategies for hAIS can be established. The outbreak of COVID-19 has had a major impact on the treatment of stroke. [1] [2] [3] [4] 7 Although patients with hAIS should be treated rapidly, physicians have to simultaneously evaluate the patients for COVID-19 infection. [5] [6] [7] Real-time polymerase chain reaction (RT-PCR) is a standard method for COVID-19 detection; however, it takes a long time to obtain the results. Therefore, the optimal time window for the treatment of stroke may be exceeded if the physicians wait until a RT-PCR result is known; conversely, stroke treatments performed without waiting for the diagnostic test results for COVID-19 involve risks of nosocomial infections. Practically, stroke treatment might have to be performed under personal protective equipment (PPE), including N95 respirators. 4, 5, 7, 21 These clinical problems can be overcome if a rapid and simple diagnostic method for COVID-19 screening can be developed. In the case presented here, we used the LAMP assay for COVID-19 screening. The LAMP assay is a rapid, sensitive, and effective visual nucleic acid amplification method that has been widely applied for the detection of certain viruses. [22] [23] [24] The results of the LAMP assay can be obtained in 30 minutes, with high sensitivity and specificity. 22, 23 Moreover, the LAMP assay does not require expensive reagents or instruments. 23 In this case, because the result of the LAMP assay revealed a negative diagnosis for COVID-19 during intravenous alteplase infusion, eCAS could be achieved with standard equipment and procedures according to the protocol of our institute without delay. Thus, the LAMP assay might be suitable for COVID-19 detection during stroke treatment because the diagnosis can be rapid. However, some uncertainty remains about whether a negative result on the LAMP assay can confirm whether the patient is truly COVID-19-free; therefore, it is advisable to use PPE, even for patients with a negative diagnosis of COVID-19. 4, 5, 7, 21 Future clinical cohort studies evaluating the LAMP assay for use in COVID-19 screening in clinical practice will be necessary. In addition, in cases that require extremely prompt treatment for stroke when a team cannot wait even for the results of a LAMP assay, it seems unavoidable that one must prioritize the stroke treatment without knowing the patient's COVID-19 infection status while following the appropriate procedures for preventing infection. 4, 5, 7, 21 Rapid and accurate diagnostic methods for detecting COVID-19 should, therefore, be developed or improved upon urgently. This case report demonstrates that eCAS for AIS due to ICS following intravenous alteplase infusion can be an effective treatment option along with appropriate antiplatelet medication and management in select patients. During the COVID-19 pandemic, the LAMP assay for COVID-19 detection might be a suitable diagnostic method preceding stroke treatment because the diagnosis can be made rapidly. A novel coronavirus from patients with pneumonia in China World Health Organization Challenges and potential solutions of stroke care during the coronavirus disease 2019 (COVID-19) outbreak Protected code stroke: hyperacute stroke man-agement during the coronavirus disease 2019 (COVID-19) pandemic Letter: academic neurosurgery department response to COVID-19 pandemic: the University of Miami/ Jackson Memorial Hospital model Preparing a neurology department for SARS-CoV-2 (COVID-19): early experiences at Columbia University Irving Medical Center and the New York Presbyterian Hospital Neurosurgical impact of coronavirus disease (COVID-19): practical considerations for the neuroscience community Long-term results of carotid artery stenting versus endarterectomy in high-risk patients National Institute of Neurological Disorders and Stroke rt-PA Stroke Study Group. Tissue plasminogen activator for acute ischemic stroke Thrombolysis with alteplase 3 to 4.5 hours after acute ischemic stroke A randomized trial of intraarterial treatment for acute ischemic stroke Randomized assessment of rapid endovascular treatment of ischemic stroke Thrombectomy within 8 hours after symptom onset in ischemic stroke Stent-retriever thrombectomy after intravenous t-PA vs. t-PA alone in stroke Endovascular thrombectomy after large-vessel ischaemic stroke: a meta-analysis of individual patient data from five randomised trials Endovascular therapy for ischemic stroke with perfusion-imaging selection Safety and effectiveness of emergency carotid artery stenting for a high-grade carotid stenosis with intraluminal thrombus under proximal flow control in hyperacute and acute stroke Emergency carotid artery stent placement in patients with acute ischemic stroke Carotid artery stenting in acute stroke Carotid Artery Stenting for acute ischemic stroke patients after intravenous recombinant tissue plasminogen activator treatment Society of NeuroInterventional Surgery recommendations for the care of emergent neurointerventional patients in the setting of COVID-19 RT-LAMP for rapid diagnosis of coronavirus SARS-CoV-2 Loop mediated isothermal amplification (LAMP) assays as a rapid diagnostic for COVID-19 Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay computed tomography; eCAS, emergent carotid artery stenting hyperacute ischemic stroke; ICA, internal carotid artery; ICS, internal carotid artery stenosis MRI, magnetic resonance imaging; NIHSS, National Institutes of Health Stroke Scale; PFC, proximal flow control; PPE, personal protective equipment We would like to thank Editage (www.editage.com) for English language editing. This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors. J o u r n a l P r e -p r o o f ACKNOWLEDGEMENTS We would like to thank Editage (www.editage.com) for English language editing. This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors. J o u r n a l P r e -p r o o f J o u r n a l P r e -p r o o f