key: cord-0916557-eme3vf9f authors: Barrios Andrés, José Luis; Carriba Rodriguez, María Justina; Aranzamendi Zaldumbide, Maitane; Hernández, Jose María; Viciola García, Margarita title: Evaluation of cleaning and disinfection protocols for severe acute respiratory coronavirus virus 2 (SARS-CoV-2) on different hospital surfaces date: 2021-01-25 journal: Infection control and hospital epidemiology DOI: 10.1017/ice.2021.23 sha: 8e4c0adec105342ac87a42219b43af2c59b542c1 doc_id: 916557 cord_uid: eme3vf9f Since SARS-CoV-2 is able to survive on inanimate surfaces, we analysed samples of several healthcare settings, to carry out a disinfection protocol assessment. Despite the accuracy of strategies set up to increase the effectiveness of the study, none of the samples showed the presence of viral specific RNA fragments. To the Editor-The coronavirus disease 2019 (COVID-19) pandemic has hit the world's population harshly, causing severe illness that may require hospitalization and sometimes even intensive care unit (ICU) admissions. 1 In fact, at certain times, a large proportion of patients admitted to hospitals have been infected by severe acute respiratory coronavirus virus 2 (SARS-CoV-2), becoming real reservoirs in the absence of proper hygiene and containment measures. The main route of transmission of SARS-CoV-2 is by droplets and aerosols; however, the role played by fomites remains unclear. 1,2 Survival on different surfaces is estimated in hours and even several days. [2] [3] [4] [5] As an enveloped virus, SARS-CoV-2 is very sensitive to the usual disinfectants. However, in some hospital units, due to the high viral load that can be shed by patients, surfaces could be repeatedly contaminated over time, becoming a potential route of transmission. 6 In this study, we evaluated the effectiveness of cleaning and disinfection procedures to eradicate the presence of the virus and therefore minimize the appearance of new sources of infection. From April 17 to June 4, 2020, 48 surface samples were prospectively collected in selected areas of University Hospital Cruces (Basque Country, Spain), a center with almost 1,000 beds that, during the study period, kept a median of 95 COVID-19 hospital patients per day, with a maximum of 165 and a minimum of 36 COVID-19 patients per day. The areas that were disinfected daily according to cleaning protocols established by the preventive medicine department of the hospital are listed in Table 1 . The following samples were collected in clinical areas: • 3 ICU boxes with COVID19 patients admitted for >5 days • 1 ICU boxes after discharge of the COVID-19 patients • ICU warehouse with disinfected devices used in COVID-19 patients • 3 general rooms with COVID-19 patients admitted >5 days • 3 general rooms after discharge of the COVID-19 patients • 1 general room without patients (control) Samples obtained from potentially contaminated objects were: pillows (n = 3), bed rails (n = 7), toilets (n = 6) and bedside tables (n = 8) in the COVID general rooms and bed rails (n = 5), shelves (n = 6) and medical equipment (n = 7) (infusion pumps and monitors) in ICU boxes. To complete the study, samples from the ICU warehouse (where the equipment is usually stored) were also collected. Samples were obtained with sterile gauze pads (70% viscose and 30% Texpla polyester) previously moistened in universal virus transport medium (UVTM). Gauze pads and transport media were pretreated in Vivaspin 6 mL ultrafiltration tubes (Sartorius AG, Göttingen, Germany) by centrifugation at 3,000 rpm for 5 minutes. Polymerase chain reaction (PCR) detection of specific genetic regions of SARS CoV-2 virus (N, Orf1ab and S) was carried out in the QuantStudio 5 equipment (both from Applied Biosystems, ThermoFisher Scientific, Waltham MA). No viral RNA fragment was detected in any of samples collected in the pre-or postcleaning samples from any of the studied areas. We evaluated the effectiveness of disinfection measures implemented in our center to eradicate, or at least reduce, the presence of the virus. For this purpose, unlike other studies, we performed sample collection with sterile gauze, dragging to collect a large amount of representative material. We also used a molecular detection technique that combines various targets of virus genome to improve the sensitivity. Additionally, we extended collection time frame to increase the probability of detecting presence of the virus. Nonetheless, we did not detect the virus in any of the studied areas. Detection of SARS-CoV-2 on hospital surfaces varies greatly. 1, 7 According to some studies, it was frequently detected before cleaning or disinfection in COVID-19 patient areas and especially on objects with greater handling 1, 2, 4, 8, 9 ; in other studies, it was only detected in isolation areas and sporadically after cleaning or disinfection. 4, 10 In our case, the main difference is that the virus was also not detected before cleaning and disinfection, even having been carried out just once a day, increasing the likelihood of surfaces being contaminated. We believe that 2 factors could have influenced the absence of detection. On one hand, the thoroughness and way of carrying out the cleaning and on the other, the remaining effect of the compounds used may have prevented contamination. The cleaning was carried out, in all cases, applying a unidirectional wave friction protocol that achieved a total drag of the material deposited on the surface. On the other hand, different compounds were used in disinfection: 3% sodium hypochlorite, accelerated hydrogen peroxide 0.32%, and quaternary ammonium compounds 0.5% with biguanide. The compound itself does not seem to be of great importance because SARS-CoV-2 is extremely susceptible to the disinfectants usually used. Instead, the format of the product might have been influential; sodium hypochlorite was used in gel form and hydrogen peroxide and quaternary ammonium, with or without biguanide, in wipes even containing surfactants in some cases. Our hypothesis is that these compounds could have had a certain postadministration duration effect that would have minimized the possibility of subsequently detecting the virus on the surfaces studied. In conclusion, these results indicate that the cleaning protocol used in our center is completely effective in eradicating the virus from the surfaces and medical devices most likely to be colonized, improving safety of patients and their environment. 6 a Samples in COVID19 patients´rooms-boxes were collected at different times: pre-cleaning or before the daily cleaning (about 24 hours after the last cleaning), and 3 hours later (post-cleaning). Detection of SARS-CoV-2 within the healthcare environment: a multicentre study conducted during the first wave of the COVID-19 outbreak in England Investigating SARS-CoV-2 surface and air contamination in an acute healthcare setting during the peak of the COVID-19 pandemic in London Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 Detection and infectivity potential of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) environmental contamination in isolation units and quarantine facilities SARS-CoV-2 in environmental samples of quarantined households Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients The role of the healthcare surface environment in SARS-CoV-2 transmission and potential control measures Severe acute respiratory syndrome coronavirus 2 RNA contamination of inanimate surfaces and virus viability in a health care emergency unit Environmental sampling for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) during a coronavirus disease (COVID-19) outbreak aboard a commercial cruise ship SARS-CoV-2 RNA detection of hospital isolation wards hygiene monitoring during the coronavirus disease 2019 outbreak in a Chinese hospital Acknowledgments.Financial support. No financial support was provided relevant to this article. All authors report no conflicts of interest relevant to this article.