key: cord-0916062-io1yqr2w authors: Misra, Dr. Satyajeet; Behera, Dr. Bikram Kishore; Elayat, Dr. Anirudh title: Novel closed-loop bronchoscopy barrier sheath: value addition for one-lung ventilation during the corona virus disease-2019 pandemic date: 2020-06-24 journal: J Cardiothorac Vasc Anesth DOI: 10.1053/j.jvca.2020.06.070 sha: d63e9c0e0f3ae03f2e4ca13d695fc12fef6fb86c doc_id: 916062 cord_uid: io1yqr2w Disclosures, conflicts of interest, funding: None. Corona virus disease-2019 (COVID-19) is a rapidly evolving pandemic with serious implications for both patients as well as healthcare professionals. One-lung anesthesia and ventilation constitutes a high-risk procedure since it entails use of repeated flexible bronchoscopy for confirmation of lung isolation, trouble-shooting intraoperative hypoxemia and bronchial suctioning during various stages of surgery; and this has the potential for aerosol generation and environmental contamination, thus endangering the safety of healthcare professionals and providers. Recommendations are in place for airway management of suspected or confirmed patients with COVID-19 undergoing thoracic surgery. 2,3 However, we did not find description of any specific strategy to prevent aerosol generation during bronchoscopy apart from recommendations for using personnel protective equipment. 2, 3 Similarly, other reports describe use of high efficiency particulate filters during one-lung anesthesia but avoid bronchoscopy to prevent risk of aerosol contamination. 4 We describe a novel and simple closed-loop method for prevention of aerosol contamination during flexible bronchoscopy and suctioning procedures during one-lung ventilation. We use a sterile non-allergenic single use plastic laparoscopic camera port cord cover as a barrier against aerosol generation for such purposes. The length of the cover is 200 cm and is open at both ends. The cover is cut according to the length of the bronchoscope leaving sufficient extra length of about 30 cm for taping at proximal and distal ends. The proximal end of the cover is taped at the bronchoscope handle and the distal end is taped around the double-lumen endotracheal tube (DLT) just proximal to the cuff inflation line ( Figure 1A ). Positioning the tape proximal to the cuff inflation line allows easy cuff inflation and deflation. The distal end also incorporates the bronchial and tracheal connectors as well as the Y-connector ( Figure 1A ). A small slit is made in the plastic sheath at the Y-connector adaptor so at to allow connection with the ventilator circuit ( Figure IA) . The cut end of the plastic sheath is then secured on the Y-connector with tape once the ventilator circuit is connected. To secure the distal end, ventilation needs to be interrupted for a few seconds and as such, patients may be ventilated with 100% oxygen for a few breaths. Once the distal end of the cover is securely taped, the protective cap at the proximal ventilating port is opened to introduce the bronchoscope into the lumen of the DLT. The scope can now be negotiated within the DLT lumen to confirm the tube position or for bronchial suctioning. The nonventilated tube connector can easily be clamped with the plastic sheath in place ( Figure IA) . We suggest leaving the scope in-situ throughout the procedure to prevent environmental contamination. The scope can be easily hung on i.v stands kept near the patient's head ( Figure 1B ). In case it is required to be removed, the proximal end of the cover can be snared or taped and closed to prevent environmental contamination with patient secretions. To reintroduce the bronchoscope or suction catheters, the proximal end is opened and the scope or catheter introduced. The margin of safety against aerosol contamination during opening the proximal end for removal or introduction of the scope or suction catheters is slightly more than the length of the scope, 51.5 cm for neonatal scope and 65 cm for pediatric and adult scopes. Additionally, the cover is kept vertical during the introduction or removal processes. This is more than the margin of safety provided by video-laryngoscopes which are widely recommended for use as a measure to increase the 'mouth-to-mouth' distance between the patient and the laryngoscopist. 5 To demonstrate the integrity of this closed-loop system, a simulation was set up. The first part of the simulation involved generating aerosols due to mechanisms like cough. We intubated an airway mannequin with a 37-French left-sided DLT (Portex®, Smiths Medical). The distal bronchial end of the DLT was connected to a manual adult resuscitator ( Figure 2A ). A few drops of methylene blue was aspirated into a syringe filled with saline and this solution was then instilled into the bronchial lumen of the DLT. A white screen was placed 4 approximately 90 cm away from the proximal end of the DLT. The manual resuscitator was then vigorously squeezed to simulate a cough. This led to generation of forced aerosol spray which stained the white screen ( Figure 2B ). The experiment was repeated with the closedloop system in place. However, despite coming out with force, the dye was contained effectively by the plastic sheath and failed to stain the white sheet in this instance ( Figure 2C & Video loop 1). We have since used the closed-loop sheath in 3 non-COVID-19 patients undergoing lung surgery. In two cases, 37-French left-sided DLTs were used and in one case, a 35-French left-sided DLT was used. The scopes used were 4.0 mm ID and 3.0 mm for the 37 and 35-French tubes respectively. The ease of negotiating the scope through the sheath cover and the DLT was graded on a 3-point Likert scale of 1-3; 1-scope negotiated easily without any difficulty, 2-moderate difficulty in negotiating the scope and 3-scope negotiation very difficult. In all cases, the score was 1, with scope negotiation performed easily, since the width of the cover is 18.5 cm which allows flexibility to maneuver the scope even after taping it at the respective ends. The covers are cheap and commercially available. Similar protective barrier have been recently reported for use with transesophageal echocardiography probes. 6, 7 Considering the fact that 41.3% of COVID-19 was hospital acquired, of which > 70% infected were healthcare professionals, 8 we suggest use of these closed-loop barriers as an additional protection against aerosol contamination in all patients undergoing one-lung anesthesia and ventilation for thoracic surgery. This will further help to save use of resource scarce personal protective equipment. There are no conflicts of interest with this submission. Video loop 1. The closed-loop bronchoscopy barrier sheath effectively contains the aerosols despite being generated with force. Perioperative management of patients infected with the novel coronavirus: Recommendations from the joint task force of the Chinese Society of Anesthesiology and the Chinese Association of Anesthesiologists Thoracic anesthesia of patients with suspected or confirmed 2019 novel coronavirus infection: preliminary recommendation for airway management by the European association of Cardiothoracic Anesthesiology Thoracic Subspecialty Committee Management of the airway and lung isolation for thoracic surgery during the COVID-19 pandemic One-lung ventilation: A simple technique to reduce air contamination during the Coronavirus disease 2019 (COVID-19) pandemic Videolaryngoscopy increases 'mouth-tomouth' distance compared with direct laryngoscopy Transesophageal echocardiography probe sheath to decrease provider and environmental contamination Preventing contamination during transesophageal echocardiography in the face of the COVID-19 pandemic Precautions for intubating patients with COVID-19