key: cord-0913719-92fx394c authors: Nagura-Ikeda, Mayu; Imai, Kazuo; Kubota, Katsumi; Noguchi, Sakiko; Kitagawa, Yutaro; Matsuoka, Masaru; Tabata, Sakiko; Miyoshi, Kazuyasu; Ito, Toshimitsu; Tamura, Kaku; Maeda, Takuya title: Clinical characteristics and antibody response to SARS-CoV-2 spike 1 protein using VITROS Anti-SARS-CoV-2 antibody tests in COVID-19 patients in Japan date: 2021-04-16 journal: J Med Microbiol DOI: 10.1099/jmm.0.001291 sha: 76326530a9a56d0f96a486cbcf2f1ab8f6ff275a doc_id: 913719 cord_uid: 92fx394c INTRODUCTION: Serological tests for COVID-19 are important in providing results for surveillance and supporting diagnosis. Investigating the serological response in COVID-19 patients with different disease severity is important for assessing the clinical utility of serological assays. GAP STATEMENT: However, few studies have investigated the clinical utility of antibody assays for COVID-19 or differences in antibody response in association with disease severity. AIM: The study aimed to evaluate the clinical characteristics and clinical utility of VITROS SARS-CoV-2 antibody tests according to COVID-19 severity in patients in Japan. METHODOLOGY: We analysed 255 serum specimens from 130 COVID-19 patients and examined clinical records and laboratory data. Presence of total (IgA, IgM, and IgG) and specific IgG antibody for the spike 1 antigen of SARS-CoV-2 was determined using VITROS Anti-SARS-CoV-2 antibody tests. RESULTS: Overall, 98 (75.4 %) and 32 (24.6 %) patients had mild and severe COVID-19, respectively. On admission, 76 (58.5 %) and 45 (34.6 %) patients were positive for total and IgG antibody assays. Among 91 patients at discharge, 90 (98.9 %) and 81 (89.0 %) were positive for total and IgG antibody, respectively. Clinical background and laboratory findings on admission, but not the prevalence or concentration of total or IgG antibody, were associated with disease prognosis. Total and IgG antibody intensities were significantly higher in severe cases than in mild cases in serum collected >11 days after onset, but not within 10 days. CONCLUSION: VITROS Anti-SARS-CoV-2 total and IgG assays will be useful as supporting diagnostic and surveillance tools and for evaluation of humoral immune response to COVID-19. Optimal prediction of disease prognosis is made from considering both clinical history and laboratory findings. The novel coronavirus disease 2019 (COVID- 19) , which is caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, was initially reported in December 2019 in Wuhan, China [1] , and it has since gained pandemic status worldwide [2] . Serological tests are important in providing results for surveillance and to support diagnosis based on the gold standard method of real-time reversetranscription polymerase chain reaction (RT-qPCR) [3] . Additionally, several reports have suggested that the antibody response to SARS-CoV-2 could be associated with disease severity [4] [5] [6] [7] [8] [9] [10] [11] . Therefore, investigating this response in COVID-19 patients is important in order to assess the clinical OPEN ACCESS Continued utility of serological assays as supporting diagnostic tools and to understand the pathogenicity of SARS-CoV-2. The serological tests currently available for detecting total, IgM, and IgG antibodies against SARS-CoV-2 include enzyme-linked immunosorbent assay (ELISA), immunochromatography assay, and chemiluminescence immunoassay (CLIA) [12] [13] [14] [15] . In particular, CLIA is widely used for COVID-19 detection in clinical settings because it is a rapid, high-throughput, and semi-quantitative method for detecting antibodies that is easy to perform. Commercial serological assays use a variety of SARS-CoV-2 antigens, including internal nucleocapsid protein (NP) and external spike (S) proteins. The S protein is composed of two subunits, S1 and S2. S1 contains the receptor binding domain (RBD), which is responsible for binding to the angiotensin-converting enzyme 2 (ACE2) receptor on the host cells at initiation of infection [16] . RBD is considered the major epitope recognized by SARS-CoV-2 neutralization antibodies [11, 17, 18] . The duration of antibody persistence after SARS-CoV-2 infection is still unclear, but a longitudinal study showed that S protein could last longer than NP [19] . Therefore, CLIA kits using S1 antigen can be used both for diagnostic support and for the assessment of humoral immunity against SARS-CoV-2. The VITROS Anti-SARS-CoV-2 Total Antibody Test and VITROS Anti-SARS-CoV-2 IgG Antibody Test (Ortho Clinical Diagnostics, Raritan, NJ) both use the S1 protein of SARS-COV-2 and have been approved by the US Food and Drug Administration as commercial CLIAs for SARS-CoV-2 [20] . However, the clinical utility of these two antibody assays for COVID-19 and differences in antibody response in association with disease severity have not been well evaluated [21, 22] . Here, we describe the clinical characteristics of patients with COVID-19 in Japan and report the clinical performance of and antibody response to the VITROS Anti-SARS-CoV-2 antibody assays for total (IgA, IgM, and IgG) and specific IgG antibodies to S1 protein of SARS-CoV-2, assessed in 255 serum samples collected from 130 COVID-19 patients with differing disease severity. This study included 130 patients with COVID-19 who were referred to the Self-Defence Forces Central Hospital, a designated medical institution for specific infectious diseases in Tokyo, Japan, from 26 February to 8 May, 2020. All were confirmed to have COVID-19 infection by RT-qPCR for SARS-CoV-2 according to the nationally recommended protocol [23] . We retrospectively collected patient information from electronic medical records. Serum samples were collected on the day of admission and during hospitalization. All serum samples were stored at −80 °C before use in the antibody tests. Total and IgG antibody assays against SARS-CoV-2 S proteins were performed using the VITROS Anti-SARS-CoV-2 Total Antibody Test and VITROS Anti-SARS-CoV-2 IgG Antibody Test (Ortho Clinical Diagnostics) according to the manufacturer's instructions. Results were interpreted in accordance with these instructions as positive (signal for test sample /signal at cutoff [S/CO]≥1.00) or negative (S/ CO<1.0) for both total and IgG assays. Symptomatic cases were then subdivided into severe and mild groups. Severe symptomatic cases were defined as patients with clinical symptoms of pneumonia (saturation of percutaneous oxygen [SpO 2 ] <93 % and need for oxygen therapy). Other symptomatic cases were classified as mild. The criterion for discharging COVID-19 patients from hospital was a negative result on two consecutive RT-qPCR tests [21] using throat swab specimens under the Infectious Disease Control Law in effect from 11 February to 13 May, 2020. Continuous variables are expressed as the mean±standard deviation (SD) or median interquartile range [IQR] and Seropositive rate of total and IgG antibody response in serum specimens collected from mild and severe COVID-19 cases after symptom onset. Plot shows seropositive rate for total and IgG antibody assays per total serum collected from symptom onset. Solid and dashed lines indicate total and IgG antibody assays, respectively. Blue and red lines indicate mild and severe cases, respectively. Ab, antibody. cases, high-flow nasal cannula therapy was required in 14 (10.8 %) and mechanical ventilation was required in five (3.8 %). Univariate analysis revealed that older age (P<0.001) and male preponderance (P=0.002) were significantly higher in the severe COVID-19 group than in the mild COVID-19 group. The prevalence of underlying disease was also higher in severe cases (P<0.001), with significant differences especially in the prevalence of hypertension (P<0.001), diabetes mellitus (P=0.013), and malignancy (P=0.014). There were no significant differences in clinical features between the two groups. Blood test results revealed severe cases had higher concentrations of aspartate aminotransferase (AST), alanine aminotransferase (ALT), lactate dehydrogenase (LDH), and C-reactive protein (CRP), higher white blood cell (WBC) count and neutrophil/lymphocyte ratio (NLR), and lower sodium level and lymphocyte count than mild cases. There were no significant differences in the positivity rate or S/CO for either total or IgG antibody assay on admission between the two groups. Ninety-one of the total 130 patients investigated had paired serum samples, collected on admission and discharge (Table 2) . Amongst these 91 on discharge, 90 (98.9 %) and 81 (89.0 %) patients were positive for total and IgG antibodies, respectively. The S/CO of total and IgG antibodies on discharge was significantly higher in severe cases than in mild cases (P<0.001 for total and P=0.009 for IgG antibodies), while there was no significant difference in the seropositive rate for either total or IgG antibody between the two groups on discharge (P>0.05). For the 255 collected serum specimens obtained from 130 patients, the period from initial symptom onset to sample collection was 1-49 (median 13 days, IQR 9-18). Among the serum specimens, the positivity rate for total and IgG increased with longer clinical course, and total antibody was detected earlier than specific IgG antibody (Fig. 1) . In mild and severe cases, total antibody assay was positive in 54. Among the 130 patients, three serum samples collected from two patients were negative for total antibody but positive for IgG antibody. Among both mild and severe cases, S/CO also increased with a longer clinical course (Fig. 2) . S/CO for the total and IgG antibody assays was significantly higher in severe cases than in mild cases among serum samples collected from patients 11-20 days after onset (P<0.001 for both total and IgG antibodies) and >21 days after onset (P=0.039 for total and P<0.001 for IgG antibodies), but there was no significant difference within 10 days (P>0.05 for both total and IgG antibodies; Fig. 3 ). Here, we have presented the clinical characteristics of patients with COVID-19 in Japan and provided evidence for the clinical utility of the VITROS Anti-SARS-CoV-2 Total and IgG assays in diagnosing COVID-19 as well as for determining differences in antibody response against the SARS-CoV-2 S1 protein with regard to disease severity. Total antibody (IgA, IgM, and IgG) for SARS-CoV-2 S1 protein was detected earlier than IgG antibody, and therefore total antibody assays appear to be preferable for initial diagnostic testing for COVID-19 in patients who develop symptoms within 2 weeks. The sensitivity of the total antibody assay was 47.8-54.4 % and 95.6-100 % in serum collected within 10 days and >11 days from onset, respectively. This finding was consistent with previous reports, which showed rapidly increased detection of IgA, IgM, and IgG antibodies against S protein from day 10-15 after onset based on ELISA [24, 25] , and other commercial CLIA kits that used the NP or S1 +2 protein as an antigen [26] [27] [28] . In this study, we demonstrated that disease severity did not affect the positivity rate of the VITROS Anti-SARS-CoV-2 Total antibody assay. Therefore, the total antibody assay will be useful in clinical settings as a supporting diagnostic tool alongside the gold standard RT-qPCR for both mild and severe cases. In addition, two patients were positive for IgG but negative for total antibody. This discrepancy suggests that they produced IgG antibody but not IgA or IgM antibody for S1 protein. Premkumar et al. [17] also reported less frequent IgA and IgM responses to the RBD (IgA: 77.6 %; IgM: 69.4 %) compared with IgG (93.8 %) at 9 days after symptom onset. Combining total and IgG antibody assay results may prevent missing the initial diagnosis of COVID-19. Regarding the timing of discharge with SARS-CoV-2 qPCRnegative viral RNA results from throat swab specimens, the positivity rate for total and IgG antibodies was 98.9 and 89.0 %, respectively. Additionally, almost 100 % of serum samples were positive for total and IgG antibodies in the late phase of the clinical course (>21 days) in both mild and severe cases. Generally, both IgA and IgM antibodies have a relatively shorter lifespan than IgG antibody. Also, IgM and IgA antibody for S1 protein is reported to be less specific than IgG [11, 29] . Taken together, the IgG antibody assay is preferable to the total antibody assay for surveillance of COVID-19 seroprevalence. Liu et al. [30] reported a strong correlation of the IgG titre against S1 with the RBD. Although further study is still needed to clarify the correlation of antibody titre determined by the VITROS Anti-SARS-CoV-2 antibody assays and neutralization antibody, the weight of evidence to date suggests that the VITROS Anti-SARS-CoV-2 antibody assays also may be used for the evaluation of humoral immunity against SARS-CoV-2. In terms of the discrepancy in antibody response to S protein with regard to severity, Zhao et al. [24] reported a significantly higher antibody titre for S protein in severe cases than mild cases based on ELISA. Our findings of higher S/CO for both the total and IgG antibody assays in severe cases in serum collected after 11 days from symptom onset are consistent with theirs. However, antibody titre within 10 days after onset or on the day of admission did not differ significantly according to disease severity. In our study, median time from symptom onset to admission and time from onset to need for oxygen therapy was 8 and 9 days, respectively. Thus, antibody titre may be an indicator of disease severity, but it may not be a predictor of prognosis in the early phase. In this study, clinical background (distribution of age, sex, and underlying disease) and laboratory findings (AST, ALT, LDH, CRP, sodium, WBC count, lymphocyte count, and NLR) on admission were associated with disease prognosis, as reported previously [31] [32] [33] [34] [35] . Therefore, it is preferable to use these clinical background characteristics and laboratory findings as predictors of disease prognosis in the early phase of the clinical course. This study has some limitations. First, despite the confirmed high specificity of VITROS Anti-SARS-CoV-2 antibody assays [20, 21] , specificity should be further analysed using additional clinical specimens from non-COVID-19 patients. Attention must be given to false-positive results of antibody assays used for initial diagnosis, especially the VITROS Anti-SARS-CoV-2 Total antibody assay given that several reports have suggested that IgM and IgA antibodies for S1 protein are less specific than IgG [11, 27] . Also, recent reports showed a time-dependent decrease in antibody titre after the initial infection, especially in asymptomatic and mild cases [36] . In the present study, we also found lower S/ CO for both total and IgG antibodies in mild cases compared with severe cases. Taken together, asymptomatic and mild cases may have a short period of S1 antibody positivity, and there is the possibility of obtaining false-negative results in post-infection surveillance by VITROS Anti-SARS-CoV-2 antibody assays. Further studies are warranted to determine the utility of VITROS Anti-SARS-CoV-2 antibody assays as diagnostic and surveillance tools for COVID-19. The qualitative results of the VITROS Anti-SARS-CoV-2 Total and IgG assays are useful, as are their S/CO values in supporting diagnosis and surveillance in both mild and severe COVID-19 cases. There are differences in antibody response to SARS-CoV-2 S1 protein according to disease severity, and thus prediction of disease prognosis in the early phase is best made by considering both the clinical history and laboratory findings. This research did not receive any specific grant from funding agencies in the public, commercial, or nonprofit sectors. Clinical features of patients infected with 2019 novel coronavirus in Wuhan, China The important role of serology for COVID-19 control Delayed specific IgM antibody responses observed among COVID-19 patients with severe progression Kinetics of SARS-CoV-2 specific IgM and IgG responses in COVID-19 patients Profile of immunoglobulin G and IgM antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Characteristics of patients with coronavirus disease (COVID-19) confirmed using an IgM-IgG antibody test Detection of IgM and IgG antibodies in patients with coronavirus disease 2019 Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort study Serological assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Severe acute respiratory syndrome coronavirus 2-specific antibody responses in coronavirus disease patients Connecting clusters of COVID-19: an epidemiological and serological investigation Performance characteristics of the Abbott architect SARS-CoV Serological immunochromatographic approach in diagnosis with SARS-CoV-2 infected COVID-19 patients Brief clinical evaluation of six high-throughput SARS-CoV-2 IgG antibody assays Structure, function, and antigenicity of the SARS-CoV-2 spike glycoprotein The receptor binding domain of the viral spike protein is an immunodominant and highly specific target of antibodies in SARS-CoV-2 patients A serological assay to detect SARS-CoV-2 seroconversion in humans A longitudinal comparison of spike and nucleocapsid SARS-CoV-2 antibody responses in a tertiary hospital's laboratory workers with validation of DBS specimen analysis 19-emergency-use-authorizations-medicaldevices/ eua-authorized-serology-test-performance Performance characteristics of four high-throughput immunoassays for detection of IgG antibodies against SARS-CoV-2 COVID-19: laboratory evaluations of serological assays Development of genetic diagnostic methods for detection for novel coronavirus 2019(nCoV-2019) in Japan Antibody responses to SARS-CoV-2 in patients with novel coronavirus disease 2019 Evaluation of nucleocapsid and spike protein-based enzyme-linked immunosorbent assays for detecting antibodies against SARS-CoV-2 Assessment of SARS-CoV-2 serological tests for the diagnosis of COVID-19 through the evaluation of three immunoassays: two automated immunoassays (Euroimmun and Abbott) and one rapid lateral flow immunoassay (NG biotech) Performance characteristics of four high-throughput immunoassays for detection of IgG antibodies against SARS-CoV-2 Comparison of the Elecsys anti-SARS-CoV-2 immunoassay with the EDI enzyme linked immunosorbent assays for the detection of SARS-CoV-2 antibodies in human plasma Cross-Sectional IgM and IgG profiles in SARS-CoV-2 infection High-accuracy multiplexed SARS-CoV-2 antibody assay with avidity and saliva capability on a Nano-Plasmonic platform Neutrophil-to-lymphocyte ratio predicts critical illness patients with 2019 coronavirus disease in the early stage Clinical course and risk factors for mortality of adult inpatients with COVID-19 in Wuhan, China: a retrospective cohort study Clinical characteristics of COVID-19 in 104 people with SARS-CoV-2 infection on the diamond Princess cruise SHIP: a retrospective analysis Risk factors for severity and mortality in adult COVID-19 inpatients in Wuhan An updated meta-analysis of AST and ALT levels and the mortality of COVID-19 patients Clinical and immunological assessment of asymptomatic SARS-CoV-2 infections We thank the clinical laboratory technicians at the Self-Defence Forces Central Hospital for sample collection, and all members of the COVID-19 Task Force at the Self-Defence Forces Central Hospital and participating members drawn from other institutes of the Japan Self-Defence Forces.Author contributions T. M. and K. I., study conception and design; M. N. I., K. I. and S. T., clinical data collection and data analysis; K. K., S. N., Y. K. and M. M., experiment data analysis; M. N. I., K. I. and T. M., manuscript drafting and editing; S. N., Y. K., M. M., T. I. and K. M., manuscript revision; T. I. and K. T., study supervision. All authors have read and approved the final manuscript. The authors declare that there are no conflicts of interest. This study was reviewed and approved by the Self-Defence Forces Central Hospital (approval number 01-011), and Saitama Medical University (approval number 917). Written informed consent was obtained from enrolled patients. Five reasons to publish your next article with a Microbiology Society journal 1 . The Microbiology Society is a not-for-profit organization. 2. We offer fast and rigorous peer review -average time to first decision is 4-6 weeks. 3. Our journals have a global readership with subscriptions held in research institutions around the world. 4. 80% of our authors rate our submission process as 'excellent' or 'very good'. 5. Your article will be published on an interactive journal platform with advanced metrics.Find out more and submit your article at microbiologyresearch.org.