key: cord-0912095-8voiqw42 authors: Snelling, William J.; Afkhami, Arsalan; Turkington, Hannah L.; Carlisle, Claire; Cosby, S. Louise; Hamilton, Jeremy W.J.; Ternan, Nigel G.; Dunlop, Patrick S.M. title: Efficacy of single pass UVC air treatment for the inactivation of coronavirus, MS2 coliphage and Staphylococcus aureus bioaerosols date: 2022-04-26 journal: J Aerosol Sci DOI: 10.1016/j.jaerosci.2022.106003 sha: 76cd10a9d53149883e65432a3d5701da33b82559 doc_id: 912095 cord_uid: 8voiqw42 There is strong evidence that SARS-CoV-2 is spread predominantly by airborne transmission, with high viral loads released into the air as respiratory droplets and aerosols from the infected subject. The spread and persistence of SARS-CoV-2 in diverse indoor environments reinforces the urgent need to supplement distancing and PPE based approaches with effective engineering measures for microbial decontamination – thereby addressing the significant risk posed by aerosols. We hypothesized that a portable, single-pass UVC air treatment device (air flow 1254 L/min) could effectively inactivate bioaerosols containing bacterial and viral indicator organisms, and coronavirus without reliance on filtration technology, at reasonable scale. Robust experiments demonstrated UVC dose dependent inactivation of Staphylococcus aureus (UV rate constant (k) = 0.098 m(2)/J) and bacteriophage MS2, with up to 6-log MS2 reduction achieved in a single pass through the system (k = 0.119 m(2)/J). The inclusion of a PTFE diffuse reflector increased the effective UVC dose by up to 34% in comparison to a standard Al foil reflector (with identical lamp output), resulting in significant additional pathogen inactivation (1-log S. aureus and MS2, p < 0.001). Complete inactivation of bovine coronavirus bioaerosols was demonstrated through tissue culture infectivity (2.4-log reduction) and RT-qPCR analysis – confirming single pass UVC treatment to effectively deactivate coronavirus to the limit of detection of the culture-based method. Scenario-based modelling was used to investigate the reduction in risk of airborne person to person transmission based upon a single infected subject within the small room. Use of the system providing 5 air changes per hour was shown to significantly reduce airborne viral load and maintain low numbers of RNA copies when the infected subject remained in the room, reducing the risk of airborne pathogen transmission to other room users. We conclude that the application of single-pass UVC systems (without reliance on HEPA filtration) could play a critical role in reducing the risk of airborne pathogen transfer, including SARS-CoV2, in locations where adequate fresh air ventilation cannot be implemented. The SARS-CoV-2 genus Betacoronavirus, subgenus Sarbecovirus) pandemic has caused significant morbidity, mortality and global disruption (Wu et al., 75 2020; Huang et al., 2020) . In response governments have implemented a series of measures under emergency powers including mandatory lockdowns, closing of nonessential businesses, the requirement of wearing face coverings in public buildings, and social distancing, together with technical measures, including track and trace systems -but change is afoot with society now reopening. As the pandemic has 80 progressed airborne transmission is now widely considered to be the main mode of transmission of SARS-CoV-2 (WHO, 2021; Greenhalgh et al., 2021; Nannu Shankar et al., 2022) . People suffering from COVID release SARS CoV-2 particles within droplets when they exhale (e.g., breathing, speaking, singing, exercise, coughing, sneezing) and as such the risk of spread and persistence of SARS-CoV-2 in diverse 85 indoor environments, including healthcare communities (Zhou et al. 2021) , educational establishments, residential areas, working spaces, retail, travel, hospitality and recreational areas, underlines the urgent need for the development of effective decontamination approaches which do not rely solely on individual action (Tang et al., 2021; Wu et al., 2020; Lancet, 2020) . Given evidence of the stability of SARS-CoV-2 90 aerosols with high levels of infectivity for at least 3 h (van Doremalen et al., 2020) , effective engineering controls could play an important role to reduce the level of biological contaminants within indoor air as part of the strategy to permit safe access to indoor spaces (Zhang et al., 2011; Lewis, 2021 ) (but they should not be considered a magic bullet). Appropriate building engineering controls include effective fresh air 95 5 2011), and/or internal production of oxygen radicals (Gerchman et al., 2019) . Whilst the mechanism of inactivation depends on the UV wavelength(s) applied , UVC with wavelength 254 nm is predominantly employed for effective, fast germicidal applications -based upon the 110 peak DNA absorption at 260 nm (Eischeid, 2011) . Retrofitting large air treatment devices into existing buildings is likely to be prohibitively expensive (Megaheda et al., 2020) and in many cases unnecessary if other interventions are deemed appropriate, however, significant transmission risk remains in highly populated indoor spaces in which adequate ventilation cannot be ensured 115 (Morawska et al., 2020) . The ability to deploy an effective, self-contained, room-based air disinfection unit capable of high throughput air exchange of between 4 and 10 air changes per hour (ACH), could be an important cost-effective tool to reduce the risk of airborne pathogen transfer, thereby aiding in the development of a safer working environment for small, medium and large spaces (SAGE, 2020; Elias et al., 2020) . 120 Recent studies have confirmed that as little as 2-ACH can be more effective than mask wearing within indoor spaces (Shah et al., 2021) . Modelling the effect of air sterilisation systems to reduce viral load can aid understanding of the potential reduction in risk of person-to-person transmission in poorly ventilated indoor spaces. The risk of airborne cross-infection has been investigated via mass balance models to 125 determine the role of transient effects and the role purging room air during breaks (Melikov et al., 2020) , with Jones et al. (2021) developing a relative exposure index considering factors that increase the likelihood of far field (> 2 m) exposure to SARS-CoV-2. Coupled to robust testing of system efficacy, an understanding of the reduction in the risk of person-to-person transmission through introduction of air sterilization 130 systems, could play an important role in demonstrating the impact and value of air sterilization in poorly ventilated spaces. Whilst there has been significant research into UVGI technologies for disinfection of air over many years (as reviewed by Reed, 2010 ) the majority of commercial UVGI 135 system lack independent data to support the efficacy of the device, often place significant reliance on pre-HEPA filtration and thereby do not address the primary technical challenge of delivery of sufficient UV dose to large volumes of air (Cutler and Zimmerman, 2011) . Recent academic interest has been focused on small scale, laboratory-based experiments demonstrating efficacy against liquid-based pathogens 140 placed on surfaces, including SARS-CoV-2 (Inagaki et al., 2020) , or examination of novel UV sources which require significant exposure times -without attempt to consider scale-up or application of treatment to indoor spaces with realistic timeframes. For example, Buonanno et al. (2020) demonstrated the effectiveness of 222-nm (far-UVC) towards viral airborne influenza virus, concluding that ~25 min 145 exposure would be required to attain 99.9% inactivation, and whilst this is promising with respect to human safety, the current cost of the technology and energy delivered prevent practical application. The application of UVC LED technology has also been reported to be effective against coronaviruses in liquid suspension tests however, again, cost-effective commercial application is challenging (Gerchman et al., 2020) . 150 UVGI microbial inactivation kinetics are directly related to the total UV energy absorbed, with engineering approaches often focused on understanding system UV dose (a function of irradiance and exposure time). To reduce power input, approaches to enhance UV dose through implementation of reflective surfaces on the chamber walls has gained attention (Ryan et al., 2010; Thatcher and Adams, 2021) . A wide 155 range of materials have been examined for this purpose, including polished metals (specular reflectors) and metal oxide films, with a range of specifically modified polymers now becoming available, including sintered polytetrafluorethylene (PTFE) for which >98% diffuse (or Lambertian) reflectivity in the UV range has been reported (Janecek, 2012) . 160 Seminal work by Jensen (1964 Jensen ( , 1967 , Tseng and Li (2005) and Walker and Ko (2007) reported the inactivation of aerosolised coxsackie, influenza, Sindbis, and vaccinia viruses, a range of bacteriophages and MS2, and adenovirus and murine coronavirus, respectively, demonstrating the effect of UV dose on the inactivation kinetics. However, only a small number of studies focus on developing understanding of the 165 properties and application of reflectors for UVC air disinfection. Ryan et al. (2010) discussed UVGI treatment of Bacillus subtilis and Mycobacterium parafortuitum, Lombini et al. (2021) in which simulations suggested efficacy against SARS-CoV-2 in high air flux systems. Given the paucity of published literature relating to potential efficacy of UVC air treatment to aid in reduction of person-to-person transmission of SARS-CoV-2, the aim of this work was to investigate the efficacy of a high velocity, single pass system 180 to deactivate relevant model pathogens (MS2, Staphylococcus aureus, bovine coronavirus)thereby negating the need for recirculation of air multiple times through the device and/or reliance on HEPA filtration. To aid with translation of the lab-based data to real world environments, scenario-based modelling was implemented within a small indoor space to investigate the potential to reduce the risk of person-to-person 185 transmission. A UVC air treatment device was developed in collaboration with Ilimex (Ballycastle, 190 Co. Antrim, UK) comprising a stainless-steel housing (1 mm material thickness) and baffles to create three consecutive UVC exposure chambers (1000 (l) x 68 (w) x 97 All glassware was sterilised by soaking overnight in 1% Virkon (Antec, UK) and steam 240 sterilised in an autoclave at 121 °C for 15 min prior to use. All culture media (Oxoid, UK) was prepared as per the manufacturer's instructions. Phosphate buffered saline (Oxoid, UK) was prepared in deionised water and steam sterilised in an autoclave prior to use. Staphylococcus aureus (ATCC 29213) and Escherichia coli (ATCC 15597) were cultured at 37 °C using Tryptone Soya Broth (TSB) and Tryptone Soya Agar (TSA). The bacterial coliphage MS2 (ATCC 15597-B1) was grown with strain E. coli as the host in TSB and harvested using chloroform and filtration (0.2 µM) as described by 250 Bonilla et al. (2016) to a confirmed titre of 1.3 x10 12 PFU/mL. All bacterial and MS2 stocks were stored at -80 °C in glycerol stocks. In preparation for treatment experiments, S. aureus was inoculated into 10 mL of TSB (TCID50) in MDBK cells via serial dilution to be 10 9 TCID50/ml. Upon receipt of treated samples, an aliquot was prepared through a series of 10-fold dilutions (10 -1 to 10 -11 ) in MEM media supplemented with penicillin (100 U mL -1 ), 275 streptomycin (100 ug mL -1 ), non-essential amino acid solution (1x) and L-Glutamine Bioaerosols were generated using a single-jet particle generating atomizer (model 9302, TSI Instruments, Buckinghamshire, UK) and directed into the air intake of the air treatment system (Figure 1 ), whereby the atomiser nozzle was inserted through the 290 top surface of the stainless-steel casing via a 10 mm diameter hole to a depth of 15 mm below the surface, delivering bioaerosol from the 3 mm internal diameter nozzle tip towards the system fan. Air samples were collected using a biosampler, (BioLite+ Pump, SKC Limited, Dorset, UK), with air sampled at the end of the UVC chamber, prior to HEPA filter. The sampling probe consisted of a 10 mm internal diameter 295 silicone tube extended into the middle of the chamber (50 mm below the top surface J o u r n a l P r e -p r o o f of the treatment system). The biosampler withdrew air samples at a fixed rate of 12.5 L/min with sonic flow delivering all airborne particles into 20 mL of sterile PBS. All equipment was maintained in a vented and extracted air handling cabinet, based upon the methods reported by Turgeon et al. (2014) . The atomiser delivering microbial 300 suspension droplet-based vapour at a flow rate of 12 mL per hour, with a number mean particle diameter of approx. 0.8 to 1.5 µm (at 25 psi)representing small, expired droplets from human subjects (expired droplet size is reported to be within the range of 0.1 μm to 1 mm, with greater than 5 µm often considered the 'large' droplets that fall with gravity (Mittal et al., 2020; Blocken et al., 2021) . For each treatment 305 experiment, 1 mL of MS2, or S. aureus, was diluted 1/100 in sterile PBS and transferred to the atomiser reservoir which was kept at room temperature for the duration of all treatment runs. For assessment of BCoV, viral particles from stock were diluted 1/10 in MEM media. Air sampling was conducted for periods of 30 min (sampling 375 L of air per 310 experiment), followed by serial dilution of the biosampler vial contents in sterile PBS and enumeration of microbes as described above. Air temperature and relative humidity were not specifically controlled within the air handling cabinet, but frequently measured at 50 ± 2% RH and 18 ±2 °C (typical indoor air conditions). During UVC treatments the temperature of the device was measured at 30 min intervals with an 315 infrared thermometer ((MM-IT01, Max Measure, UK), and at no time did the system temperature rise above 40 o C. Control experiments were performed to determine the effects of atomisation on 320 microbial viability, using samples removed from the atomiser reservoir and samples of atomised microbes collected by condensation into a sterile Falcon tube. Baseline 'air only' experiments (0 mJ/cm 2 UVC) were conducted with passage of microbes through the device assessed in quadruplicate. Each UVC exposure experiment was repeated in duplicate, with replicate experimental runs conducted with new pathogen stock. 325 Data points from culture-based enumeration methods and repeated experimental analysis are reported as mean values. A two-tailed t-test was used to assess significance of the inclusion of the PTFE liner. The model developed by Jones et al. (2021) for estimation of the relative risk of exposure to SARS-CoV-2 was adopted to investigate the practical application of the prototype device to remove COVID-19 RNA copies in an appropriate small room (e.g. medical examination room, small office etc of 15 m 3 ). We consider that the space has 335 no fresh air ventilation, with the UVC prototype implementing 5 air changes per hour (ACH) (SAGE, 2020) with the lowest UVC dose (the system with a single lamp would have the footprint of a shoe box). The scenario considered a single infector (an adult male) sitting for 5 h shedding virus at a constant rate (G = 29.2 RNA copies/s, as described in detail by Jones et al. (2021) ). The air within the room was assumed to 340 be well-mixed with virus removal due to only biological decay and UVC inactivation within the treatment system. The rate of change in the number of viral RNA copies (n) in the space at time t (s) was expressed as: where (s -1 ) is the total removal rate, calculated as the sum of biological decay (λ= 345 0.000148 s -1 ), surface deposition (γ= 0.000143 s -1 ), and the ventilation removal rate of the device based on the 2.4-log inactivation of bovine CoV achieved with the minimal UVC dose of the prototype (5 mJ/cm 2 ), ψ= 0.00139 s -1 . The effect of the system on airborne viral load was investigated for a period of 5 h 350 through three scenarios in which the infected subject remained seated in the room: (i) the UVC device turned off; (ii) the device turned on as the subject enters the room at time zero; (iii) subject entering at time zero, with the device turned on at t = 2.5 h. The Relative Exposure Index (REI) approach of Jones et al (2021) was adopted to determine the impact of system introduction with one room occupant exposed to the 355 single infected subject over a 5h period (respiratory activity 75% breathing: 25% talking, no natural ventilation); given these constraints, the rate of reduction in the number of RNA copies equals the rate of change in the REI. Increased facial intensity was observed with the PTFE liner vs the Al foil, resulting from additional reflectivity at 254 nm for PTFE (>97%) in comparison to Al (~ 75%) primarily due to the diffuse property of the sintered PTFE (Quill et al., 2016) . Analysis of the cumulative energy from a single lamp demonstrated a 34% increase upon inclusion of the PTFE chamber liner (vs Al foil), with an 11% increase observed with dual lamp. 385 Commercial literature often describes a greater increase in reflected energy through inclusion of PTFE materials in comparison to metallic reflectors (Porex, 2021; de Sternberg Stojalowski and Fairfoull, 2021) , though measurements are made using low-power sources and at distances of up to 1.5 m from the source via qualitative sensors, thus preventing a direct comparison. 390 Cumulative irradiance divided by the sampled area (base of chamber 1) permitted calculation of the area-weighted average facial intensity (mW/cm 2 ), which is often considered equivalent to the minimal fluence rate. The product of exposure time and fluence rate dictated the fluence, the UV dose (mJ/cm 2 ), as reported in Table 1 . 395 The challenges of accurate measurement and modelling of UV dose and the associated comparison to microbial inactivation have been raised by several authors. 400 Ryan et al., determined the fluence rate via actinometry and a radiometric approach yielding reasonable agreement (12% difference) describing how classical fluence models do not accurately reflect complex system geometries nor consider UV reflection or air flow profiles (Ryan et al., 2010) . To aid in reactor development, Retamar et al. (2019) proposed a radiation field model for an annular reactor and 405 demonstrated validity through radiometric measurement and experimentation. Given the debate, the work in this manuscript follows recommendations by Lombini et al. (2021) , and references within, who draw particular attention to the necessity of experimental validation of microbial inactivation rather than reliance on prediction from energy/dose measurements. 410 To ensure a standardised approach to determination of microbial inactivation during treatment, regular pre-assessments and controls were routinely conducted. Tables 2 and 3 summarise MS2 and S. aureus inactivation, respectively. Baseline control experiments in the absence of UV (0 mJ/cm 2 ), termed 'air only', were undertaken to permit direct comparison of the effect of increasing UV dose. Following 30 min 'air only' treatment, the MS2 titre at the sampling port was determined to be 435 6.48 ± 0.17 log PFU/mL; in-keeping with the expected dilution factor and therefore demonstrating capacity within the experimental set-up and methods to assess up to 6-log inactivation resulting solely from the effects of UV treatment. Passage of aerosolized S. aureus through the treatment device with 'air only' resulted in recovery of 4.70 ± 0.16 log CFU/mL, representing the maximum inactivation quantifiable with 440 UV treatment. Inactivation experiments were performed with increasing number of UV sources, demonstrating a dose dependent response (Tables 2 and 3 and Figure 3 ). Complete inactivation (4.7 log) of S. aureus was achieved with lower energy upon inclusion of the PTFE liner (1.25 log difference when compared to Al foil; p<0.001) demonstrating the practical effect of the enhanced diffuse reflectivity of the PTFE liner. Increased UVC dose was required to reach complete inactivation of MS2, however a 6.48 log reduction was confirmed. The increased reflectivity of the PTFE liner again demonstrated a practical effect with approx. 1-log additional inactivation (p<0.01) 450 observed when compared to Al wall liners with equivalent lamp output. Figure 3 shows the UV survival curve for MS2 and S. aureus, in which the D90 for MS2 (dose required for 90% MS2 inactivation) equals 20 J/m 2 with an inactivation rate constant (k) of 0.119 m 2 /J, both figures lying within the range reported by Tseng and Li (2005) and Walker and Ko (2007); and a D90 and k for S. aureus equal to 23 J/m 2 and 0.098 m 2 /J 455 respectively. We report large velocity UV sterilisation (1254 L/min) attaining 6-log inactivation of MS2 via single pass treatment, without reliance on HEPA filtration. Previous work in this area has been primarily based on laboratory systems with low flow rates (e.g. 0.2 to 4 L/min (Ryan, 2010) , 33 L/min (Retamar et al., 2019) , 60 L/min (Walker and Ko, 460 2007 ) and up to 120 L/min (Thatcher and Adams, 2021) where multiple passes and very small air change rates prevent practical application to the challenge presented by airborne viral pathogens within indoor spaces. Trendlines represent curve fits to the exponential decay equation (Eq 1). 475 Bovine CoV was used as a surrogate for SARS-CoV2 with experiments conducted with air treatment system walls lined with PTFE. BCoV titres were stable in MEM 480 media (± 10%) for up to 3 h during storage in the atomiser reservoir, with fresh stock prepared if required (TCID 50 /mL = 6.5 log). Atomisation did not significantly reduce the titre. Optical microscopy images of the tissue culture infectivity assay are shown in Figure 4 . The qualitative effect of high BCoV infectivity upon with the confluent growth of host cells ( Figure 4A ), is evident in Figure 4B where the cytopathic effect 485 can be observed by characteristically rounded and floating 'inactivated' host cells. Figure 4D represents the effects of UVC air treatment of BCoV, in which the confluent growth demonstrates no infectivity from the applied viral particles -the UVC treatment has completely inactivated the bovine coronavirus. The cytopathic effect was quantified through the TCID 50 method, with data presented in Table 4 . Passage 490 through the air treatment system in the absence of UVC resulted in reduction of titre to 2.4 log ± 0.14. Based upon the MS2 dilution though the system, the 4 log BCoV reduction factor represents an additional 1 log reduction, resulting from physical/mechanical stress and/or desiccation effects on this more susceptible pathogen. Complete inactivation (2.4 log being the maximum attainable reduction with 495 the viability assay used) was observed following passage through the system with the lowest UVC dose vs the 'air only' controls (0 mJ/cm 2 ). RT-qPCR demonstrated levels of BCoV RNA remained equivalent both pre-and post-UVC treatments. Consequently, we conclude that while the viral particles physically remained in the air, we demonstrate UVC treatment renders the particles non-infectious. A similar 500 molecular based assessment mechanism was reported by Qiao et al (2021) during UVC disinfection of bioaerosols, with systematic losses within the duct system similarly not observed. There is a growing interest in methods to reduce the risk of airborne transmission of viral pathogens on farms (Arruda et al., 2019) , and to the best of our knowledge this 505 is the first report of effective UVC inactivation of airborne bovine coronavirus, a pathogen which is associated with calfhood diarrhoea (Mebus et al., 1972) and implicated as a contributor in the development of bovine respiratory disease complex (Ng et al., 2015) . hepatitis virus (MHV) coronavirus as viral aerosols exposed to a range of UV doses (source output at 254 nm), determining that UVC treatment of coronavirus aerosols required 7-10 times less energy (UVC dose) than MS2, approximately 2.7 mJ/cm 2 for 1-log reduction of MHV (D90). Following the 2009 H1N1 influenza (swine flu) 515 pandemic, McDevitt et al. (2012) demonstrated susceptibility of H1N1 to UVC doses ranging from 4 to 12 J/m 2 showcasing the potential for effective upper-room UVC installations to prevent airborne transmission of influenza. During the more recent pandemic, Biasin et al. (2021) reported 3-log inactivation of SARS-CoV-2 with a UVC dose of 3.7 mJ/cm 2 but highlighted the variation in literature-reported doses ranging 520 from 3 to 1000 mJ/cm 2 . At approximately the same time, Qiao et al. (2021) reported inactivation of porcine respiratory coronavirus in a duct based, single pass UVC system. Using culture-based viability assays they measured inactivation in excess of 2.2-log at a flow rate of 2439 L min −1 (13.9 mJ cm −2 ) and 3.7-log at 684 L min −1 (49.6 mJ cm −2 ). The authors also note the challenge of developing high viral load 525 bioaerosols and the limitations presented by low sensitivity culture-based infectivity assays -as such UVC inactivation of coronaviruses could indeed be greater than that measured and reported in these studies. The 3-log coronavirus deactivation at the lowest dose attainable in this work (a minimum of 5.0 mJ/cm 2 with a single lamp and PTFE liner) is therefore well within the expected effective dose with findings concurring 530 with those reported in the above studies. Figure 5 shows the number of viral RNA copies, n(t), over time for three indoor roombased scenarios, where the prototype system is operated at its minimum UVC dose. Without the device (A), n(t) continuously rises during the 5 h period, whereas with the 545 presence of the device in the room upon arrival of the infected subject (B), a low-level steady state was quickly achieved (0.49 h to reach 95% of the steady state number) and maintained (after 5 h the steady state number of RNA copies remained 82.57% lower than in the absence of a device). In the scenario in which the device was turned on 2.5 h after arrival of the infected subject (C), the model predicts the number of RNA 550 copies to be quickly reduced to that of the 95% steady state (within 0.72 h) and constantly maintained at this low level. The introduction of the system over the 5 h period reduced the relative exposure index (REI) by 81.9% demonstrating a significant reduction of the risk of airborne person to person transmission. rate of 29.2 RNA copies/s, removal due to biological decay, natural particle deposition 560 and UVC treatment, UV dose of 5 mJ/cm 2 , fan flow rate of 1254 L/min.) We demonstrate that single pass UVC air treatment (1254 L/min) can effectively inactivate MS2 (6-log reduction), S. aureus (4.7-log reduction) and bovine coronavirus 565 (2.4-log reduction) with a relatively small footprint prototype (to the limits of detection of the assays employed). Inclusion of a PTFE wall liner generated increased UVC reflection permitting additional inactivation of S. aureus and MS2 (approx. 1-log) vs a standard Al reflector, demonstrating the potential for reactor engineering to play a role in enhancing UV dose to further reduce the system footprint. Modelling demonstrated 570 the small prototype to be effective at the lowest UV dose within an indoor setting, where a significant reduction in viral DNA copies was quickly achieved and maintained A B C J o u r n a l P r e -p r o o f subject. Although the parallel arrangement of the lamps to the air flow provides effective exposure of pathogens to the photons, further optimisation of lamp power 575 and position relative to the reflective surface could be undertaken with the multi-source configuration in conjunction with increasing air flow. Future studies will also be directed towards reduction in device footprint and energy consumption, and validation of the modelling in simulated and real-world settings. The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. Aerosol detection and transmission of porcine reproductive and respiratory syndrome virus (PRRSV): What is the evidence, and what are the knowledge gaps? Comparison of UV-induced inactivation and RNA damage in MS2 phage across the germicidal UV spectrum A review of methods to reduce the probability of the airborne spread of COVID-19 in ventilation systems and enclosed spaces UV-C irradiation is highly effective in inactivating SARS-CoV-2 replication Ventilation and air cleaning to limit aerosol particle concentrations in a gym during the COVID-19 pandemic Phage on tap-a quick and efficient protocol for the preparation of bacteriophage laboratory stocks Far-UVC light (222 nm) efficiently and safely inactivates airborne human coronaviruses The efficacy of ultraviolet light-emitting technology against coronaviruses: a systematic review Ultraviolet irradiation and the mechanisms underlying its inactivation of infectious agents Comparison of reflective properties of materials exposed to ultraviolet-C radiation The involvement of superoxide radicals in medium pressure UV derived inactivation UV-LED disinfection of coronavirus: Wavelength effect Ten scientific reasons in support of airborne transmission of SARS-CoV-2 Clinical features of patients infected with 2019 novel coronavirus in Rapid inactivation of SARS-CoV-2 with deep-UV LED irradiation Reflectivity spectra for commonly used reflectors Inactivation of airborne viruses by ultraviolet irradiation Bacteriophage aerosol challenge of installed air contamination control systems Modelling uncertainty in the relative risk of exposure to the SARS-CoV-2 virus by airborne aerosol transmission in well mixed indoor air UV Rate Constants. Ultraviolet Germicidal Irradiation Handbook COVID-19: protecting health-care workers COVID-19 rarely spreads through surfaces. So why are we still deep cleaning? Design of optical cavity for air sanification through ultraviolet germicidal irradiation Aerosol susceptibility of influenza virus to UV-C light Neonatal calf diarrhea: results of a field trial using a reo-like virus vaccine Antivirus-built environment: Lessons learned from COVID-19 pandemic Intermittent occupancy combined with ventilation: An efficient strategy for the reduction of airborne transmission indoors Growth and laboratory maintenance of Staphylococcus aureus The flow physics of COVID-19 How can airborne transmission of COVID-19 indoors be minimised SARS-CoV-2 in residential rooms of two self-isolating persons with COVID-19 Air disinfection for airborne infection control with a focus on COVID-19: Why germicidal UV is essential A metagenomics and case-control study to identify viruses associated with bovine respiratory disease UV Reflective Media Resources Greater than 3-log reduction Ultraviolet reflectance of microporous PTFE Molecular mechanisms of ultraviolet radiation-induced DNA damage and repair The history of ultraviolet germicidal irradiation for air disinfection Dose estimation methodology for the UV inactivation of bioaerosols in a continuous-flow reactor Inactivation of airborne microorganisms using novel ultraviolet radiation sources in reflective flow-through control devices EMG: Potential application of air cleaning devices and personal decontamination to manage transmission of COVID-19 Experimental investigation of indoor aerosol dispersion and accumulation in the context of COVID-19: Effects of masks and ventilation COVID-19 has redefined airborne transmission Impact of surface reflection on microbial inactivation in a UV led treatment duct Inactivation of virus-containing aerosols by ultraviolet germicidal irradiation Comparison of five bacteriophages as models for viral aerosol studies Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1 Effect of ultraviolet germicidal irradiation on viral aerosols Roadmap to improve and ensure good indoor ventilation in the context of The SARS-CoV-2 outbreak: What we know A new coronavirus associated with human respiratory disease in China Can commonlyused fan-driven air cleaning technologies improve indoor air quality? A literature review Breath-, air-and surface-borne SARS-CoV-2 in hospitals This research was partly funded through the Invest Northern Ireland Innovation J o u r n a l P r e -p r o o f Declaration of interests ☐ The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.☒ The authors declare the following financial interests/personal relationships which may be considered as potential competing interests:Patrick Dunlop reports financial support was provided by Invest Northern Ireland. Patrick Dunlop reports financial support was provided by UK Research and Innovation. Louise Cosby reports financial support was provided by Northern Ireland Department for the Economy.