key: cord-0911562-hnbwsynd authors: Pierre‐Bez, Alexandra C.; Agostini‐Walesch, Gina M.; Bradford Smith, P.; Hong, Qing; Hancock, David S.; Davis, Megan; Marcelli‐Munk, Gina; Mitchell, John C. title: Ultrasonic scaling in COVID‐era dentistry: A quantitative assessment of aerosol spread during simulated and clinical ultrasonic scaling procedures date: 2021-08-28 journal: Int J Dent Hyg DOI: 10.1111/idh.12548 sha: 1140b3bcd587f2bcccf6da74df3e7dc7331b963a doc_id: 911562 cord_uid: hnbwsynd OBJECTIVE: Healthcare agencies recommend limited use of aerosol‐generating procedures to mitigate disease (COVID‐19) transmission. However, total dispersion patterns of aerosols, particularly respirable droplets, via dental ultrasonic units is unclear. The purpose of this study was to characterize and map total spatter, droplet and aerosol dispersion during ultrasonic scaling in simulated and clinical contexts. METHODS: Ultrasonic scaling was performed on dental simulation units using methylene blue dye‐stained water. All resultant stain profiles were photoanalysed to calculate droplet size and travel distance/direction. Airborne particle concentrations were also documented 0–1.2 m (0–4ft.) and 1.2–2.4 m (4–8ft.) from patients during in vivo ultrasonic scaling with a saliva ejector. RESULTS: Stain profiles showed droplets between 25 and 50µm in diameter were most common, with smaller droplets closer to the mouth. In‐vivo particle concentrations were uniformly low. The smallest (<1 µm, PM1) and largest (>10 µm, PM10+) particles were most common, especially within 1.2 m (4ft.) of the patient. Respirable particles (PM2.5) were uncommon. CONCLUSIONS: Tests showed the highest concentration of small droplets in zones nearest the patient. While uncommon, particles were detected up to 2.4 m (8ft.) away. Furthermore, observed particle sizes were consistent with those that can carry infectious agents. Efforts to mitigate the spread of inhalable aerosols should emphasize proximate regions nearest the procedure, including personal protective equipment and the use of evacuation devices. furthest point at which data were collected. 6 To date, most research on dental aerosols, including the real-time studies cited above, use fluorescent dyes [15] [16] [17] or bacterial colony-forming units (CFUs) to understand aerosol spread following dental procedures. 4, 18 These methods typically rely on 'spot collection' wherein contamination is assessed at relatively few surface locations in an examination room, on personal protective equipment (PPE), or other limited areas. 5, 11, 19 Furthermore, the direction that a droplet or particle travels is often not included in the study design. These points are important given that the pattern of aerosol concentration (and associated contamination risks) is a product of both travel distance and direction. 20 Therefore, the placement of sampling points likely has a considerable effect on subsequent results. Here, two complimentary tests were used to determine particle and droplet size and dispersion during ultrasonic scaling: [ positioned in full recline with the mouth 71.1cm (28in.) above floor level atop a 2.7 × 2.7 m (9 × 9 ft.) section of white paper on which a 2.4 × 2.4m (8 × 8 ft.) perimeter was drawn. After the procedure, the paper was marked with a grid, quadrants and key landmarks to facilitate later digitization ( Figure 1 ). The water reservoir of a Dentsply Cavitron was filled with 500cc reverse osmosis (RO) water and 0.5 g methylene blue dye, after which an experienced operator performed ultrasonic scaling on typodont teeth #6-11 for 5 minutes using a saliva ejector continuously (50% power and lavage, water flow rate 18 mL/min). Afterwards, the paper was left undisturbed for 10 minutes to allow stain-bearing droplets and spatter to settle and dry. Pilot tests were conducted using variably sized floorplan grids containing droplets of different sizes and concentrations. These confirmed that a series of five overlapping photographs of each box in a 7.6 × 7.6 cm [3 × 3in.] grid system [camera height 30.5 cm (12in.)] were necessary to acquire high-resolution images (preservation of smallest droplets) and a sufficient number of landmarks to facilitate undistorted composite photograph creation (Fig. S1 ). The floorplan was systematically photographed using a Nikon Composite images were exported as uncompressed TIFs. ImageJ 21 was used to scale and threshold the images to isolate stain profiles of blue droplets. Regions of interest (ROIs) were created to demarcate specific zones corresponding to the distance from origin (patient's mouth) ( Figure 1 ). Particles in each ROI were counted using the Analyze Particles feature. Each image was inspected for obvious non-stain particles (eg hair, dust and debris). Associated data points and highly elongated stains were removed to ensure isolation of true droplets and spatter. Stain profiles produced by droplets upon surface contact are a product of speed, direction upon impact, droplet properties (viscosity, density and surface tension) and substrate (surface roughness). 22 To calculate droplet diameter, the minimum Feret diameter for each stain profile was applied to published formulae to estimate droplet diameter for water on paper using the Swath Kit ™ system, whose imaging technology had a resolution most comparable to ours. 23 Based on the resolution limits of our camera, the smallest reliably detectable stain profile had a diameter of 23.26 µm. This To assess real-time particle spread, particle concentrations were documented every second during ultrasonic scaling in two zones: (Table S1 ) up to concentrations of 150mg/m 3 with a sensitivity of 0.001mg/m 3 (Table S2 ). To capture data commensurate with the stain tests and to control for differences in procedure length between participants, data were extracted from a standardized, 5-minute timeframe at the midpoint of each procedure. The mean laboratory temperature was 21.1°C (range 19.9-22.0°C). An ANOVA with post hoc Tukey showed significant interaction between zone and quadrant, indicating a significant effect of distance (Table 1) . Of the four smallest sizes observed, droplets with diameters between 25 and 50 µm were most prevalent in each zone (Fig. S2 ). Baseline particle concentrations were very low, with just 0-98 seconds during which particles were detected across 51,043 individual readings (1/second) (Table S2) . It was, therefore, unnecessary to normalize data against the baseline as in other studies. 24 Real-time particle mass concentrations during scaling procedures were also low (Table 2) , though there was marked between-subject variation for PM1, PM10 and PM10+ particle sizes (Table S3 ). PM1 (the smallest detected) and PM10+ (largest) particles were highest in overall concentration (Table 2 ). PM1 particle concentrations dropped 70% as the distance from patient increased beyond 1.2 m (4 ft.), while PM10 particle concentrations decreased by 50% and PM10+ decreased by In terms of detection frequency, results showed PM1 (submicron) particles were the most common, followed by the largest (PM10+) ( Total number of seconds for which a non-zero particle concentration count was observed at a 5-minute midpoint sample taken during ultrasonic scaling. sampled (Table S4 ). In contrast, PM1 particles were detected only 65 seconds out of the 51,043-second baseline (clinic closure) readings. PM10+ particles were detected at an average of 48 seconds (±31.78) out of 300 seconds within 1.2 m (4 ft.) from the patient. However, they were only detected 14 seconds of the 51,043 seconds of clinic closure. These results show marked particle increases during ultrasonic scaling. As with particle mass concentrations, there is marked variation in detection frequency across subjects (Table S4 ). Droplets with diameters between 25 and 50 µm were most prevalent in each zone during the simulation test, followed more distantly by 3.96m (13 ft.) 16 While overall particle concentrations measured in this study were very low (<0.001mg/m 3 for most particle sizes), our real-time tests detected particles at distances up to 2.4 m (8 ft.) in all directions and our simulation test detected droplets nearly 1.2m (4 ft.) from the source-the maximum distances for each study. Other studies using bacterial quantification and contamination mapping show viable bacteria spread throughout dental operatory spaces, likely due to transport by aerosols containing irrigants and lower levels of patient saliva. 5, 25 In total, the results of these studies and ours show aerosolized particles produced during ultrasonic scaling decrease as distance from the source increases, but that there is potential for distant contamination by aerosol spread. PM1 particles were most prevalent in overall detection frequency. While PM1 particles are unlikely to transport larger bacteria, they can transport smaller virus particles (eg 70-120 nm SARS-CoV-2). 26, 27 However, their small size and low travel velocity means they may be exhaled before settling in the respiratory tract, though this claim is the subject of ongoing debate due to many extenuating physiological and environmental factors that influence particle movement trajectories. 28, 29 This is not true of PM2.5 particles, which can enter and settle in deeper parts of the respiratory system where they may absorb into the bloodstream and pose infection risk. 30 However, these particles were uncommon in our real-time tests. This may indicate ultrasonic scaling produces comparably less PM2.5 particles, or that they are disproportionately captured by standard saliva ejectors. Aerosols produced via ultrasonic scaling contain a mixture of irrigation solutions, saliva, blood, bacteria and other respiratory or oropharyngeal debris that can cause surface and PPE contamination or disease transmission via inhalation. 4, 5, 31, 32 Our real-time test showed that a 30kHz magnetostrictive ultrasonic unit produced more PM1 particles during dental prophylaxis than any other particle size. Similar results were reported for tooth preparations by Liu et al., 33 wherein 96.78% of total suspended particles were PM1 when no evacuation was used. As a result, the authors conclude that almost all particles generated during drilling and grinding of extracted natural teeth were PM1. Results are similar for in vivo tooth preparations, which primarily produce particles <3.0 µm, but do so at higher concentrations. 24 Further investigation into the production of ultrafine particle concentrations during ultrasonic scaling is needed to include smaller, potentially contaminated aerosols, as existing evidence predicts that any PM1-, PM2.5-or PM10-sized particles could transmit COVID-19 and other viruses. 34 The minimum droplet size necessary to transport SARS-CoV-2 is unknown, but coronaviruses range from 70 to 120nm in size. 26, 27 A recent study of Wuhan Province hospitals during the COVID outbreak showed that out of five size ranges, the highest concentration of SARS-CoV-2 particles was 0.25-1.0µm (submicron) and 2.5µm+ (fine or supermicron). 39 Evacuation devices are, therefore, necessary to protect the health of dental healthcare providers (DHCPs). Other spatter mitigation strategies include personal protective equipment to limit the risk of inhalation and exposure, and protective barriers to limit potential transmission via contact with contaminated surfaces. Preprocedural mouth rinses, such as chlorhexidine and cetylpyridinium chloride, can reduce bacterial load in dental aerosols by 68.4%. 41 Pre-appointment toothbrushing can also reduce airborne contamination during dental procedures. 10 The best protocols to protect against viral transmission via aerosols and spatter is likely to be one that uses myriad, multilevel strategies to protect both DHCPs and their patients. COVID-19 has raised concerns regarding aerosols generated during dental procedures, including the length of time these aerosols remain airborne and the distance they can travel. Our tests identified areas closest to the patient as those with the highest density of small, potentially respirable particles, that this concentration decreases with increased distance, that droplets disproportionately travel in directions opposite the operator working arm, and that all five particle size groups evaluated can be detected up to 2.4m (8 ft.) away from the patient's mouth during ultrasonic scaling with a saliva ejector. This demonstrates the importance of aerosol and spatter mitigation strategies for all dental procedures, including those associated with dental ultrasonic use. Few studies have used whole room mapping to measure the distance and direction of droplet and aerosol spread from ultrasonic scaling instruments. Concentrations of droplets and spatter produced during ultrasonic scaling decrease at distances further from the source; however, distant surfaces in all directions can become contaminated. Significant contamination was observed opposite the operator, in the dental assistant zone. Due to the maximum potential spread of contaminated droplets and aerosols, dental healthcare professionals must use appropriate personal protective equipment and aerosol mitigating strategies to reduce contact with contaminated aerosols and surfaces. We would like to thank Vivian Jauregui, Stella Amaya and several other members of the clinical staff for their help in preparing key elements of this research. The authors declare that they have no conflict of interest. APB and GA had primary responsibility for conceptualization, clinical and simulation data collection, analysis and writing. QH and MD assisted with project development and photoanalytical data collection. DH was involved in project development and data collection. BS and JCM were responsible for supervision, resources, conceptualization and manuscript review. GMM assisted with project execution. Alexandra C. Pierre-Bez https://orcid.org/0000-0003-2533-291X Transmission routes of 2019-nCoV and controls in dental practice Transmission routes of respiratory viruses among humans Aerodynamic characteristics and RNA concentrations of SARS-CoV-2 aerosol in Wuhan hospitals during COVID-19 outbreak Contamination of surgical mask during aerosol-producing dental treatments Sources of SARS-CoV-2 and other microorganisms in dental aerosols Splatters and aerosols contamination in dental aerosol generating procedures Bacterial aerosols in the dental clinic: a review Infection Prevention and Control of Epidemic-and Pandemicprone Acute Respiratory Infections in Health Care. World Health Organization Aerosols and splatter in dentistry: a brief review of the literature and infection control implications Evaluating spatter and aerosol contamination during dental procedures Review of Respirable Particle Size Range. Nuclear Decommissioning Authority Particle size and pathogenicity in the respiratory tract Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals Protective device to reduce aerosol dispersion in dental clinics during the COVID-19 pandemic Evaluating aerosol and splatter following dental procedures: addressing new challenges for oral healthcare and rehabilitation Dissemination of aerosol and splatter during ultrasonic scaling: a pilot study Reduction of microbial concentration in the air of dental operating rooms: I. High-efficiency particulate air filters Dental aerosols: microbial composition and spatial distribution Whole-room mapping of aerosolized spatter. Poster presented at: International Association of Dental Research Image processing with ImageJ Deducing drop size and impact velocity from circular blood stains Comparison of three imaging systems for water-sensitive papers Measurement of particle concentrations in a dental office Topographic aspects of airborne contamination caused by the use of dental handpieces in the operative environment Identification of Coronavirus isolated from a patient in Korea with COVID-19 Does size really matter? Relationship of particle size to lung deposition and exhaled fraction Particle deposition in tracheobronchial airways of an infant, child, and adult Air quality: Particle pollution Aerosol and splatter contamination from the operative site during ultrasonic scaling Bacterial aerosols released during dental ultrasonic scaling in dogs Removal efficiency of central vacuum system and protective masks to suspended particles from dental treatment A clinical study measuring dental aerosols with and without a high-volume extraction device Quantification of influenza virus RNA in aerosols in patient rooms Measurements of airborne influenza virus in aerosol particles from human coughs Influenza virus aerosols in human exhaled breath: particle size, culturability, and effect of surgical masks Size distribution analysis of influenza virus particles using size exclusion chromatography Aerosols in ultrasonic scaling: comparing particle spread using saliva ejectors and high-volume evacuation The efficacy of an extraoral scavenging device on reduction of splatter contamination during dental aerosol generating procedures: an exploratory study Possible aerosol transmission of COVID-19 and special precautions in dentistry