key: cord-0910981-xep01y7y authors: Motamedi, H; Shirzadi, Mohammadreza; Tominaga, Yoshihide; Mirzaei, P A title: CFD Modeling of Airborne pathogen transmission of COVID19 in confined spaces under Different Ventilation Strategies date: 2021-10-03 journal: Sustain Cities Soc DOI: 10.1016/j.scs.2021.103397 sha: a0dcb149d6b702d70cb37acdf4bfa95be17413dd doc_id: 910981 cord_uid: xep01y7y Airborne transmission is an important route of spread of viral diseases (e.g., COVID-19) inside the confined spaces. In this respect, computational fluid dynamics (CFD) emerged as a reliable and fast tool to understand the complex flow patterns in such spaces. Most of the recent studies, nonetheless, focused on the spatial distribution of airborne pathogens to identify the infection probability without considering the exposure time. This research proposes a framework to evaluate the infection probability related to both spatial and temporal parameters. A validated Eulerian-Lagrangian CFD model of exhaled droplets is first developed and then evaluated with an office case study impacted by different ventilation strategies (i.e., cross- (CV), single- (SV), mechanical- (MV) and no-ventilation (NO)). CFD results were analyzed in a bespoke code to calculate the tempo-spatial distribution of accumulated airborne pathogens. Furthermore, two indices of local and general infection risks were used to evaluate the infection probability of the ventilation scenarios. The results suggest that SV has the highest infection probability while SV and NO result in higher dispersions of airborne pathogens inside the room. Eventually, the time history of indices reveals that the efficiency of CV and MV can be poor in certain regions of the room. Droplets exhaled by different respiratory events is responsible for spread of COVID-19 airborne pathogens from infected to exposed occupants. In particular, airborne transmission of these pathogens is believed to be one of the major routes of the disease propagation [1] . On the other hand, flow field inside confined spaces are mainly formed based on the applied ventilation strategy, which can promote further the airborne transmission of respiratory airborne pathogen droplets [2] . During pandemic of COVID-19, the necessity in development of better ventilation systems for indoor environments has been highlighted by many ventilation associations such as ASHRAE [3] . In general, ventilation systems are divided into natural and mechanical systems. The former relies on passive airflow through openings, while the later uses fans and ducts to bring the fresh air inside the target space. In this regard, ASHRAE, REHVA and WHO have published documented guidelines with the aim of improving indoor areas ventilation system and air quality [4, 5] . Besides that, extensive research works has been conducted to investigate the impact of ventilation on propagation of pollution at indoor areas. Melikof [6] and Thatiparti [7] stated that building-up viral contamination in a confined space can be avoided by proper placement of inlet and exhaust ducts to assure that sufficient level of dilution is achieved. In many similar studies, the target was to replace the polluted air with the clean air. However, this requirement is not always met because of barriers existing inside rooms. On the other hand, in most of public buildings like shops, offices, schools, public transport, etc., ventilation rate is not sufficient for the economical purposes. So, According to Kulkarni et al. [8] and Sornboot et al. [9] with low ventilation rates in indoor environments, the infection probability will rise among the occupants in enclosed spaces. In order to investigate the impact of ventilation systems on propagation of pollutants in restricted spaces both experimental and numerical techniques have been developed [12, 13] . The outbreak of respiratory infections in the past decade has attracted far more attentions to apply CFD to study transmission routes of airborne pathogens in different environments under different ventilation strategies. processes and evaluated their potential impacts on an adjacent person in a room with displacement ventilation system. They found that a normal respiration process is associated with a low risk of infection while in case of sneeze or cough, the risk would elevate to a large extent, depending on occupants' relative orientation. They used thermal manikin with real geometry to precisely resolve the flow field in the micro-environment around the subjects. Exhaled flows were modeled by tracer gas [15] . Seepana pathogens inside an open office room during cough. The office room was ventilated using supply and return ducts on the ceiling while different scenarios were defined for the position of infected subjects and barrier heights. They proposed that physical barriers with the height of 60 cm provides an effective prevention against pathogens' transmission. Exhaled pathogen droplets were considered as a continuum phase and species-transport equation was solved to determine their propagation inside the room [20] . In general, it can be concluded that the application of CFD in simulation of pathogen transmission in restricted spaces reveals that research works in this area are mostly limited on modeling of certain aspects of airborne pathogens modeling since full representation of the physics underlying propagation of exhaled droplets such as evaporation, condensation, coagulation, etc., can result in a complex model. Most of the numerical studies on the spread of infection such as COVID19 employ air quality exposure indices, which generally incorporates concentration sources at a room's inlet and exhaust to assess contaminated regions within an enclosed environment. For example, Liu et al. studied the transmission of short-range exhalation droplets between two occupants. They used susceptible exposure index to estimate the viral load intake, which is exhaled by an infected occupant [21] . Ai et al. also used exposure index to investigate the impact of pulmonary ventilation rate and breathing cycle period on the infection risk [22] . Nonetheless, aside from the exposure to the airborne pathogens, the number of viruses transmitted with the droplets remains as a key factor in the disease transmission. In this aspect, Karimzadeh et al. stated that the minimum infective dose of COVID-19 in humans is higher than 100 particles [23] . Basu introduced a strategy, by synergizing computational tracking and virologic data, to quantify the infectious dose [24] . Buonanno et al. suggested a novel quantitative approach to estimate the risk of airborne transmission of COVID-19 infection. For this purpose, they divided the whole process into evaluation of the emission rate, exposure to a dosage concentration, received dosage and infection probability calculations [25] . Despite of the mentioned efforts, a crucial gap in these studies is that estimation of infection risk needs accumulated dosage of viral loads, which cannot be directly extracted from the outputs of CFD simulations. In other words, physical social distance is not the only determining factor in the prevention of airborne pathogen infections, but the exposure time is mutually crucial. For instance, if an exposed occupant receives only a small viral load per unit time from a distant infected occupant in a long enough time, this can gradually reach the minimum infective dosage. On the other hand, keeping the safe social distance in some places is not practical due to a high concentration of people or lack of enough spaces to ensure keeping the proper distance between all occupants. Office rooms, in general, are characterized by both long exposure times and confined spaces that make it difficult to set a safe distance between all the workers. Hence, evaluating the temporal infection risk can be a beneficial assessment in selection of suitable ventilation strategies and even working hours management. Thus, this paper aims to proposes a framework to develop risk models that accounts the accumulation of exhaled airborne airborne pathogens under different ventilation scenarios within confined spaces. Thus, the proposed framework predicts the tempo-spatial infection risk based on the outputs of a CFD model, taking into the consideration of the pivotal factors in the pathogen droplet transmission such as evaporation and droplets' size distribution. The framework is then applied to an office room under different ventilation strategies to assess their performance in restriction of pathogen droplets propagation inside the room. For this purpose, a CFD model of a room under a natural ventilation strategy was first validated against an experimental wind tunnel test data. Then, three human manikins were added to the simulation domain to consider the effect of their thermal plume on the room background flow. After that, the droplet release of speaking mode from manikins was modeled inside the room in a one-hour timespan. Droplets' distribution and size were adapted from the related clinical literature using a time dependent Lagrangian approach. Finally, a separate bespoke code was developed to exploit accumulated distribution of droplets extracted from CFD output results to calculate a 3D distribution of airborne droplets as well as the temporal probability of infection inside the modeled office room. Section 2 is the methodology section, which introduces the governing equations, applied models and infection probability model. Section 3 presents the selected case studies i.e., crossventilation (CV), single-ventilation (SC), mechanical-ventilation (MV) and no-ventilation (NV). Then, numerical setup for both continuous and discrete phases are discussed in Section 4. Validation of the introduced numerical setup is also reported in this section. Finally, the simulation results, including airflow distribution and resultant particle concentrations, isosurfaces of infection probability, global and local risks as well as time-dependent infection risk for the cases are presented in Section 5. The applied methodology to assess the performance of ventilation system from viewpoint of infection risk has two main steps. First, a transient CFD simulation is implemented to track the pathway of the exhaled droplets during a speaking mode. The outputs of the CFD results are then transferred to a bespoke code to estimate the accumulated concentration of droplets during the simulation run-time and to calculate the infection probability based on available clinical data of a minimum threshold of airborne pathogens' transmission against COVID-19. Details of Eulerian-Lagrangian CFD model used to simulate airborne pathogens' release is presented in this section. Steady incompressible Eulerian model includes governing equations for continuity, momentum, and energy conservation equations as the following: (1) where represents the velocity vector and is the source term, which models the added mass from discrete phase of droplets to the surrounding air. In which is the pressure, and ̅̅̅̅̅ represent viscosity and Reynolds stresses, respectively and is the sum of all body forces exerted. Also, the energy equation can be expressed as follows: where and are temperature and sensible enthalpy, is the thermal conductivity and represents the source term [26] . Lagrangian model is applied to model the trajectory and distribution of the discrete respiratory droplets exhaled from a bio-source's mouth. where is the particle (or droplet) mass, is the continuum phase velocity vector, is the particle velocity vector, is the continuum phase density, is the droplet density, is the gravity constant, is the additional exerted force and is the particle relaxation time, which can be calculated as: (5) in which is the particle diameter and is the drag coefficient. is the relative Reynolds number that is calculated as: According to Vejerano et al., the exhaled droplets comprises water and non-evaporating salt and protein [27] . Once it is discharged to the environment, its water content evaporates. So, mass transfer occurs between the phases, which can be influenced by temperature difference between continuum and discrete phases, resulting on droplet's size change. Thus, mass transfer and heat transfer equations are presented as follows [26] : where denotes the mass of the particle, and ̇ represents the rate of mass transfer to the particle. The right side the above equation is necessarily non-zero when evaporation takes place. Suitable modeling of ̇ has a crucial impact on the accuracy of the results. For cases associated with high rates of evaporation, where the convective impact of evaporating material from the droplet plays an important role, the following formula proposed by Miller et. al can be used: where k c is the mass transfer coefficient, A p is the droplet surface area, ρ is the gas density and B m is Spalding mass transfer coefficient, which can be obtained as: (9) where and represent the vapor mass fraction at the surface and the bulk gas, respectively. As a basic assumption, one can assume that droplets are internally homogeneous. From a thermal point of view, this is equal to a low Biot number (< 0.1). Thus, the equation of conservation of energy can be expressed as: where and are the droplet heat capacity and temperature, is the convective heat transfer coefficient, is the temperature of the continuous phase and is the latent heat of the droplet phase. Eq. (10) in fact relates the heat exchange in droplets due to sensible and latent heat transfers between droplets and the continuum phase, which is added as a source (or sink) term to Eq. (3) [26] . The proposed framework to evaluate the airborne infection risk of virus includes five steps as illustrated in Figure 1 . First, the instantaneous distribution of exhalation droplets is calculated in step-1 using a CFD solver and required inputs as per step-0. In the step-2, the accumulated concentration of droplets is calculated all over the room. The viral load carried by exhaled droplets of respiratory systems is determined in step-3, which results in resolving the tempospatial distribution of infective viruses in a target space. In step-4, the dose received by an exposed occupant is estimated. Finally, a dose-response model is applied to find the infection probability for exposed occupants who have already received certain quanta of virus during a specific time interval. As stated earlier, CFD simulation of the model comprises the step-0 and step-1of risk assessment respectively. Other steps from second to fifth one according to Figure 1 will be further discussed in the following sections with more details. As mentioned in Figure 1 , estimation of the emitted viral load is the step-3 in the infection risk calculation. Therefore, a forward emission approach proposed by Buonanno et al. [20] is adapted to estimate the quanta emission ( ) per hour as follows: (11) where is the sputum viral load (RNA copies mL -1 ), is the infectious quantum divided by infectious dose (quanta per RNA copies -1 ), is the inhalation rate ( ) and is the volume concentration of exhaled droplets by an infected occupant (ml m -3 ). , and values are selected according to the previous studies [25] . Some works have suggested that strongly depends on the respiratory activity [18, 19] . It should be noted that ( ) in the form presented in Eq. 11 is not directly applicable to emission and distribution of airborne pathogens inside the room as it is calculated using a 3D CFD model while Eq. 11 assumes a uniform emission of viral load all over the room. Therefore, this equation will be further adjusted to be employed in the 3D CFD model. For this purpose, it is suffice to calculate the accumulated particles inside each cell within the target timespan. This concentration comes from CFD solution and depending on the background flow of the room can be irregularly distributed inside the room. According to Eq. 11, the dimension of the term is , which represents the viral load carried by a droplet with the volume of one .Therefore, timedependent accumulated concentrations of the viral load at each cell will be calculated according to the following equation: where ( ) is the time-dependent quanta concentration of the viral load, To facilitate the calculation of the accumulated concentration of the viral load throughout the field (step-2 according to Figure 1 ) selected domain is uniformly meshed which is called the secondary mesh. Then, the spatial concentration of droplets is calculated at each cell during the time span of simulation. A schematic representation of secondary mesh and accumulated droplets is shown in Figure 2 . Hence, the output results of Eulerian-Lagrangian CFD simulations will be conducted by development of a bespoke code, which generates a secondary uniform and coarse mesh inside the room. Since trajectory of each particle parcel is reported at each time-step in the output results file, accumulated droplets can be found at each element of the secondary mesh. After that, based on the volume of the concentrated droplets, accumulated viral load is exploited. Calculated viral loads is then used to evaluate the infection risk distribution inside the room after one hour of simulation. To calculate the droplets' dosage taken by exposed occupants at each computational cell, in relation with step-4 of Figure 1 , the accumulated quanta concentration is calculated from Eq. (12) . Other required data include inhalation rate of subjects as well as the exposed time. Hence, integrating the quanta concentration over time according to the following equation represents the received dosage: where is the received dosage by exposed occupants, T is the simulation time and IR is the inhalation rate (m 3 h -1 ) of the exposed occupant, which strongly depend on the respiratory event while the estimated values can be found in [30] . The step-5 of the framework, as presented in Figure 1 , is the calculation of the infection probability. Amongst available dose-response models in the literature, a simplified model of Poisson summation equations is chosen to evaluate the infection probability of the exposed subjects expressed as: (14) where P I is the probability of the infection stated in percentile [25] . The cases study office room is a small office with dimensions of ( ). Different ventilation strategies as explained in the following sections were applied to this room while three occupants are assumed to work in this office for one hour. So, each occupant occupies nearly a 60-square foot area in accordance with the available guidelines [31] Arrangement of the occupants was selected in a way that they stay in a maximum distance from each other while seated. At each simulation case, there is only one infected occupant. Therefore, the influence of different ventilation strategies as well as the position of infected occupant on the dispersion of airborne pathogens and distribution of infection probability is investigated. As shown in Figure 3 , circular cylinders were used to mimic the seated occupants while thermal plumes were generated by assigning heat flux on their skins. The height of the cylinders is 1 meter. Overall size of the room and windows were the same for all cases. Exhaled activity of the infected occupant is a normal speaking mode. This activity is assumed to be continuous for a time span of one hour. Droplets are released into the room with a size distribution as presented in Table 1 with an initial velocity of [32] . Mouth is modeled as a source point and the impact of nose is not modeled. Speaking is considered as a steady activity to further simplify the modeling. The propagation of airborne pathogens and therefore the risk of infection under different ventilation strategies is defined as the investigated scenarios. In Case CV, the office room is assumed to have two opposite openings with dimensions of ( ) as presented in Figure 3 . Outdoor airflow was set such that the maximum air velocity inside the office room remains below to be able to compare this case with the other strategies. Case SV is identical to Case CV except that only one of the opposite windows is open as shown in Figure 3 . So, the flow pattern in this case will be quite different from that of CV strategy. NV ventilation strategy ventilation is characterized by isolated airflow of the room from outside flow field as depicted in Figure 3 . However, a realistic approach requires that a small air leakage to occur between the indoor and outdoor spaces. In this case, the flow field inside the room is significantly affected by the thermal plume of the occupants. Specifications of the mentioned ventilation strategies is described in Table 2 . The calculated air exchange rate (ACH) in the table is a measure of the air volume added to or removed from a space in one hour divided by the volume of the space [5] . This index is shown as it is an import one in the ventilation design of spaces. For each case of Table 2 , volumetric airflow of the room and maximum air velocity inside the room are determined through postprocessing of the simulation results. The flow field was simulated using steady Reynolds averaged Navier-Stokes (SRANS) approach in Ansys Fluent 19.0. Turbulence was modeled by realizable (RLZ) [33] and enhanced wall-function was adopted to solid walls of the office as well as the ground in the outdoor spaces. Second-order upwind scheme was used to discretize transport equations and SIMPLE algorithm was applied to model the pressure-velocity coupling. Exhaled droplets were simulated using Discrete Phase Model (DPM). In the DPM computations, interactions between droplets and the surrounding air (continuous phase) were considered and droplet equations source terms were updated after every single iteration of the solution of the continuous phase. Droplet time-step was set as 0.01 second and the overall simulated time was 1 hour. Convergence level of 10 -5 was applied to control the accuracy of the particle tracking. Implicit and trapezoidal schemes were selected as the particle tracking strategies. According to the literature, respiratory droplets will evaporate rapidly after being exhaled until they turn into non-evaporative nuclei, which are responsible for airborne propagation of airborne pathogens [34] . Hence, here droplets were modeled as a multi-component type, nearly up to 95 percent of which consists of water and were allowed to be evaporated [27] . For Cases SV and CV, the airflow distribution outside the building was also included to obtain more accurate air distribution inside the building while for Cases MV and NV cases, only the airflow distribution inside the building was considered. So, for modeling of Cases SV and CV, a rectangular flow domain as shown in Figure 4 was generated according to AIJ guidelines. According to this guideline, the top and lateral boundaries should be placed at least from the building surfaces. While the distance between inlet boundary and building is confined by the maximum allowed space by the wind tunnel, outlet boundary is suggested to be at least far from the building's wall [35] . Overall dimension of the domain is ) are plotted in Figure 5 for all mesh settings. In general, the deviation between three meshes was not so high, however, medium, and fine meshed showed very close values all over the three vertical lines. The settings for medium mesh was used for the CV and SV cases. The same mesh configuration was applied to the MV and NO cases. Inlet boundary conditions to the target environment were obtained from a power-law profile from AIJ category V with an exponent of and a boundary layer height of for a reference height of using the recommendations by AIJ guideline [35] : where ( ) is the streamwise velocity at the height of and is the reference velocity at the reference height . Distribution of different exhaled droplet sizes was extracted from the literature [32] as presented in Table 1 . Boundary conditions required to solve the described case studies is also shown in Table 3 . It should be noted that hydraulic diameter for Cases MV and NO is set as 1.08 m. Furthermore, since the continuum is solved on a steady state basis, the defined humidity at the inlet propagates through and reaches to a time-independent condition all over the domain, including the office room. For this purpose, the inlet humid air is modeled as a mixture of water and air species. [39] [40] [41] [42] . The indoor velocity field over a vertical plane was measured using a two-dimensional (2D) particle image velocimetry (PIV) system (SEIKA Digital Image Corporation). Mist oil droplets with nominal diameter of were released upstream of the building model using a droplet generator (CTS-1000). the building model was made by transparent acrylic plates with 3-mm thickness which makes it possible to capture reflection images from the vertical plane inside the building. A Double pulse YAG laser (Photonics Industries DM20-527 PIV) with a high-speed camera (FASTCAM MiniAX 50) were installed above and in front of the building, respectively. The image resolution per pixel was about 0.2 mm/pixel while the camera frame rate was set to 1000 Hz. All PIV analyses were conducted using Koncerto II software provided by Seika Digital Image, which is based on Fast Fourier transform (FFT)-cross correlation with the multi-grid interrogation method [45] . The Gaussian distribution function was used for sub-pixel interpolation of the velocity field. The reference velocity was at the building roof height ( ). The wind tunnel profiles for U, TKE, and ε can be found in [44] . Vertical profiles of the time-averaged stream-wise velocity over three vertical lines at are shown in Figure 6 for CFD and wind tunnel measurement. According to Office flow pattern has a substantial impact on both dilution and dispersion of airborne pathogens and therefore studying the flow field may give an insight of droplets streamlines. Considering the size of the released droplets and their rapid evaporation, which drastically reduces their sizes, the impact of droplets on the larger scales of the flow field inside the room is quite low. So that the generated flow field inside the office room can be considered independent from the position of the infected occupant. The flow field inside the room, instead, is strongly influenced by the ventilation strategy and thermal plume of the occupants. In other words, at each ventilation strategy, the airflow patterns are identical no matter which occupant is the infected one. The velocity contours of the described ventilation strategies are depicted over the horizontal and vertical mid-planes as illustrated in Figure 7 and Figure 8 . An overall comparison of the contours implies that NV and SV strategies reveals that the velocity in the mid parts of the room is at its lowest range while upward motion of the air near the walls can be found to be considerable due to the thermal plume of the occupants. One key point is to consider that the infection of an exposed occupant is not only a function of the concentration of airborne pathogens, but it significantly depends on the duration of the exposure. This means that infection happens if the exposed occupant receives a certain dosage of the viral load. Thus, this needs accumulative calculation of airborne pathogens reaching to the exposed occupant. The non-zero background airflow inside a room simultaneously disperse and dilute the airborne pathogens. So, if the droplets are not modeled, it is nearly impossible to quantify the infection risk and to determine either dispersion or dilution of the pollutants is the dominant phenomenon. Hence, ventilation strategy will be simulated three times with identical boundary conditions considering that the position of the infected occupant changes in different scenarios. For instance, CV1 refers to the cross-ventilation scenario in which the occupant number 1 (according to Figure 3 (a)) is infected and two other occupants are exposed. 3D scatter diagram of infection probability in Case CV, in accordance with the introduced methodology at section 2.2, is presented in Figure 9 . As it can be seen, scattered diagrams are Figure 9 is that the highest risk of infection can be observed at 1.5m to 2m distance from the infected occupant. Figure 9 . Infection probability (in percent) of CV and SV strategies with different position of the infected occupant 3D Scatter plot of the infection probability of SV case is also depicted in Figure 9 . In this figure, SV2 and SV3 show a similar infection risk distribution, which is mainly caused by the upward motion of the thermal plumes. The central zone of the room, however, encounters a low airflow movement. So, in SV1 and in the absence of an effective airflow, a great deal of the pathogens falls and then a high-risk part of this room will be in the lower half of the room. In other words, airborne transformation mechanism is nearly weak in Case SV1. Figure 10 . In general, this strategy results in a strong dispersion of the airborne pathogens all over the room. In fact, the ventilation type combined with the thermal plume leads in a strong flow field inside the room, which is responsible for a strong propagation of the airborne pathogens. For example, while the thermal plume of the cases MV2 and MV3 moves upwards and reaches the ceiling, that of the case MV1 is cut off under the influence of the inlet flow. Therefore, the propagation of airborne pathogens in MV1 will be quite different from that of the cases of MV2 and MV3. Case NO infection risk inside the room after 1 hour is shown in Figure 11 . Since no ventilation exists in the room, case of NV3 is identical to NV1 due to a geometric symmetry. As expected, lack of ventilation in the presence of the thermal plum disperses the droplets continuously in an upward direction. It can be concluded that NV and MV results in a higher dispersion of the airborne pathogens in the office room. Moreover, the health risks of CV and SV strategies are generally dependent on the relative position of the infected occupant and location of the windows. 3D scatter data of the infection probability presented in section 5.2 can also be represented in an iso-surface form. Iso-surface reported here are geometric locus of points in the room having the same infection probability. So, if properly set, iso-surfaces can be regarded as a border that separates high risk infection zones from lower ones. In this section, iso-surfaces of different ventilation strategies, assuming that occupant-1 (see Fig. 3 ) is infected, are presented in Figure 12 . This provides a useful tool to investigate details of the infection risks in indoor spaces. Here, the selected onset value for the iso-surface is selected as 10 percent. This means that the regions wrapped by such surfaces have infection risks of equal or above 10 percent while the infection probability outside of this surface becomes below 10 percent after one hour. Assuming that occupant-1 is infected, the growth of the infection risk in terms of the global and local indices within the simulation timespan are depicted in Figure 13 and Figure 14 , respectively, for different ventilation strategies. According to Figure 13 , the highest infection risk can be found in the SV strategy. The NV strategy is the next case while CV and MV show the lowest risk level. One noticeable fact that can be drawn from this diagram is that NO, MV and CV present nearly identical trends in the increase of the global index at first 2,400 seconds of the simulation. As the exposure time increases, however, NV strategy gradually deviates from the other two. This means that the accumulation of the airborne pathogens depends on the ventilation type and consequently on the flow field inside the room as it can significantly change through the time. The local index parameter is also illustrated in Figure 15 for the susceptible persons i.e., IP_2 and IP_3. Both diagrams of Figure 15 a and b illustrate that Cases SV and NV results in the highest infection risks for the susceptible occupants. The only different behavior that can be seen is that Case MV imposes a higher infection risk on IP_2 while the infection risk of IP_3 is higher when CV is applied. This implies that the performance of ventilation system in restriction of airborne pathogens propagation at the near field (the infected case) is different from the far field regions (IP_2, IP_3). So, a proper evaluation of a ventilation system requires that the local index is applied to all occupants in the room. It also indicates that the position of occupants has a considerable influence on the level of the infection risk. Table 4 may not show a serious infection risk after one hour, this gives a measure to compare the performance of different ventilation strategies in propagation of airborne pathogens inside the room. Hence, the risk can be developed in a longer period of simulation and exposure time of the occupants. As seen in the Table 4 Table 5 , IP_1, IP_2 and IP_3 represents the occupants of the room, each of which can be considered as the infected occupant and others as the exposed ones. Here, it is assumed that IP_1 is the infected person and IP_2 and IP_3 are the exposed occupants. According to Table 5 , the infection risk around the occupant_1 (IP_1) is nearly similar in all four scenarios. Although in NO, the local infection risk is lower than that of other cases; this implies that the micro-environment around the infected occupant is not strongly influenced by the ventilation strategy. For the exposed occupants (here, IP_2 and IP_3) in the office room, however, this is not necessarily true. According to the local infection risk of occupant-2 and occupant-3, it is evident that the infection probability of the exposed occupants is strongly affected by the selected ventilation strategy. For instance, while the SV and CV types provide a same infection risk value for the infected occupant, the probability of infection for occupants 2 and 3 in the case of SV is 15.9% and 2.9%, respectively, which is considerably higher than 4.7% and 4.6% as calculated in the case of CV. Based on the results of Table 5 , it can also be concluded that in the office room, the infection probability does not necessarily drops as the distance from the infected occupant increases. Although this is a valid point for the cases of NO, MV and CV, in SV, the infection risk of occupant-3 is higher than occupant-2 while the distance of occupant-3 from the infected occupant is higher. This shows that a social safe distance in an office room is deeply affected by the selected ventilation strategy and not merely the distance from the infection source. Similar calculations can be conducted for ventilation cases in which a second or a third occupant is infected. This is a critical issue in designing suitable ventilation strategies for office rooms and gives a practical means to assess the existing ventilation cases. To assess the airborne transmission of airborne pathogens inside confined spaces like office rooms, a framework is presented in this paper. According to the proposed framework, a case study of airflow inside an office room is simulated using CFD technique. Exhaled droplets during the speaking activity are modeled using the available data in literature about droplets' size and distribution. Captured data of the instantaneous position of droplets' trajectories is then directed to a computational bespoke code to calculate the accumulated viral loads all over the office room. The room is occupied by three occupants while different ventilation strategies (i.e., CV, SV, NV and MV) as well as the position of the infected occupant is investigated to evaluate the performance of the bespoke code at different situations. Following remarks can be concluded from the simulation results:  3D scatter plots of the infection probability and its associated 2D slice contours can be regarded as a useful mean to assess the dispersion of pathogen droplets inside a room under influence of different factors such as selected ventilation type, relative position of infected and exposed occupants inside the room and the exposure time. For example, the infection risk in the case of MV1 is more uniformly dispersed inside the room compared with SV1. Nevertheless, this does not necessarily mean that SV1 has a better performance in general. The proposed framework can be applied to assess the designed ventilation system, managing work hours and also find optimum layout of occupants in confined spaces like office rooms. One important feature of the present research work is that it adds output data of CFD to the infection risk models through the calculation of accumulated droplets inside the room and also application of clinical data on COVID-19 infective dosages. By inserting a wide range of exhaled droplet sizes (from 3 to 750 microns) and inclusion of evaporation and defining droplets as a multicomponent material, a fraction of which is not evaporated, a more realistic airborne behavior of airborne pathogens can be obtained inside the room. One of the restrictions of the present research work is that simple cylinders mimic the occupant, which can have an impact on the flow field and infection risk in microenvironment around them. One-hour timespan of the simulations also imposes a limitation. Although one hour is not a considerable time-span compared to daily work hours, it should be pointed out that the main aspect and novelty of this work is that it proposes a framework that can be applied to investigate the contribution of different ventilation strategies to infection probability in different confined spaces. Realistic time spans will be subject of future works of the authors to demonstrate practical capabilities of the introduced framework. Thus, further assessments are needed with longer work hours. Another point to mention is that room geometry is simple, and furniture is not considered in this research work, which can have an impact on the flow pattern inside the room. It is well understood that every piece of furniture or barriers inside the room can alter the flow patterns and consequently the propagation of aerosols in the room. So, our future work will focus on finding practical solutions and guidelines to minimize the risk of pathogens airborne transmission in more realistic confined spaces for diverse applications. Airborne transmission of SARS-CoV-2: The world should face the reality A systematic review of possible airborne transmission of the COVID-19 virus (SARS-CoV-2) in the indoor air environment In-Room Air Cleaner Guidance for Reducing Covid-19 In Air In Your Space/Room ASHRAE 62.1 (2019) Ventilation for acceptable indoor air quality Standard 62.2-2013: Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings Advanced air distribution: improving health and comfort while reducing energy use Computational fluid dynamics study on the influence of an alternate ventilation configuration on the possible flow path of infectious cough aerosols in a mock airborne infection isolation room Evidence of Respiratory Syncytial Virus Spread by Aerosol. Time to Revisit Infection Control Strategies? Detection of airborne Mycobacterium tuberculosis complex in high-risk areas of health care facilities in Thailand CFD Prediction of Airflow in Buildings for Natural Ventilation the Use of Cfd Tools for Indoor A cough aerosol simulator for the study of disease transmission by human cough-generated aerosols Version and A. Universitet, human breathing and its interactions with room ventilation Xu CFD Simulation of the Airborne Transmission of COVID-19 Vectors Emitted during Respiratory Mechanisms: Revisiting the Concept of Safe Distance Transient CFD simulation of the respiration process and inter-person exposure assessment Experimental and numerical investigation of interpersonal exposure of sneezing in a full-scale chamber Numerical Simulation of Coughed Droplets in the Air-Conditioning Room Numerical Simulation of Coughed Droplets in Conference Room Effects of cough-jet on airflow and contaminant transport in an airliner cabin section Mitigating COVID-19 infection disease transmission in indoor environment using physical barriers Short-range airborne transmission of expiratory droplets between two people Influence of pulmonary ventilation rate and breathing cycle period on the risk of cross-infection Review of Infective Dose, Routes of Transmission, and Outcome of COVID-19 Caused by the SARS-CoV-2 Virus: Comparison with Other Respiratory Viruses Computational characterization of inhaled droplet transport in the upper airway leading to SARS-CoV-2 infection Quantitative assessment of the risk of airborne transmission of SARS-CoV-2 infection: Prospective and retrospective applications ANSYS Fluent Theory Guide Physico-chemical characteristics of evaporating respiratory fluid droplets Surfing the COVID-19 scientific wave The airborne lifetime of small speech droplets and their potential importance in SARS-CoV-2 transmission Measurement of breathing rate and volume in routinely performed daily activities Office Space Standards and Guidelines Government of the Northwest Territories Characterization of expiration air jets and droplet size distributions immediately at the mouth opening A new k-ϵ eddy viscosity model for high reynolds number turbulent flows Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings CFD analysis of the human exhalation flow using different boundary conditions and ventilation strategies Performance of new wind tunnel of Niigata Institute of Technology Wind tunnel tests on the relationship between building density and pedestrian-level wind velocity: Development of guidelines for realizing acceptable wind environment in residential neighborhoods CFD modeling of pollution dispersion in a street canyon: Comparison between LES and RANS Cooperative project for CFD prediction of pedestrian wind environment in the Architectural Institute of Japan Wind tunnel analysis of flow and dispersion in crossventilated isolated buildings: Impact of opening positions Wind tunnel experiments on cross-ventilation flow of a generic building with contaminant dispersion in unsheltered and sheltered conditions Experimental study on cross-ventilation of a generic building in highly-dense urban areas: Impact of planar area density and wind direction Wind tunnel experiments on crossventilation flow of a generic sheltered building in urban areas Iterative multigrid approach in PIV image processing with discrete window offset The faculty of Engineering of The University of Nottingham is acknowledged.