key: cord-0909851-gny0me00 authors: Lee, Nuri; Jeong, Seri; Park, Min-Jeong; Song, Wonkeun title: Comparison of three serological chemiluminescence immunoassays for SARS-CoV-2, and clinical significance of antibody index with disease severity date: 2021-06-29 journal: PLoS One DOI: 10.1371/journal.pone.0253889 sha: 68c62c61a172e571ded253adfc2d4528d074c773 doc_id: 909851 cord_uid: gny0me00 BACKGROUND: The clinical significance of the quantitative value of antibodies in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection remains mostly unidentified. We investigated the dynamics and clinical implications of the SARS-CoV-2 antibody over time using three automated chemiluminescence immunoassays targeting either nucleocapsids or spikes. METHODS: A total of 126 specimens were collected from 23 patients with confirmed and indeterminate COVID-19 identified by molecular tests. SARS-CoV-2 antibody index was measured using SARS-CoV2 IgG reagent from Alinity (Abbott) and Access (Beckman Coulter) and SARS-CoV2 Total (IgG + IgM) from Atellica (Siemens). RESULTS: Three immunoassays showed strong correlations with each other (range of Pearson’ s correlation coefficient (r) = 0.700–0.854, P < 0.001). Eleven (8.7%) specimens showed inconsistencies. SARS-CoV-2 IgG showed a statistically significantly higher value in patients with severe disease than that in non-severe disease patients (P < 0.001) and was significantly associated with clinical markers of disease severity. CONCLUSION: The quantitative value of the SARS-CoV-2 IgG antibody measured using automated immunoassays is a significant indicator of clinical severity in patients with COVID-19. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is spreading rapidly worldwide, with high mortality and infection rates. According to the World Health Organization (WHO) dashboard, as of December 24, 2020, 76,858,506 infections and 1,711,498 deaths have been reported worldwide. People infected with SARS-CoV-2 mainly show respiratory symptoms and fever [1] and are associated with pulmonary fibrosis [2] and systemic inflammatory diseases in children [3] . In addition, severe infections in high-risk patients are associated with a mortality rate of 2.7% in men and 1.8% in women [4] . Currently, laboratory tests using molecular diagnostic methods are being conducted for the early diagnosis and isolation of infected persons. However, molecular diagnostic tests demonstrate a high sensitivity in the early stages of the infection, but the detection rate decreases with time. In addition, no information on the patient's immunity to SARS-CoV2 infection is currently available [5, 6] . To compensate for these limitations, a number of SARS-CoV-2 antibody tests have been developed, but these tests have not yet been sufficiently evaluated and have not yet been applied in actual clinical practice. In addition, serum IgG/M tests have been mainly reported using enzyme immunoassay (ELISA) or rapid diagnostic kits [7] . Both test methods have drawbacks in clinical application. Since ELISA tests are not automated, it is difficult to obtain results within an appropriate time period, and rapid diagnostic kits have the disadvantages of accuracy and difficulty in handling large quantities of tests. Therefore, it is necessary to evaluate the clinical usefulness of the SARS-CoV-2 antibody test using automated equipment. Several antibody tests currently being developed are designed to detect various regions of the SARS-CoV-2 virus antigen [8] . Since the antigen detection site is different for each antibody test as designed by the manufacturer, there may be differences in the performance of each test. Comparative evaluations for each test are necessary to identify the advantages and disadvantages of each manufacturer's kit and to select an appropriate kit according to the patient's underlying disease. In addition, the interpretation of quantitative antibody results (S/ CO index) derived through each test has not been evaluated, and the clinical significance of the quantitative value needs to be analyzed. Therefore, in this study, several SARS-CoV-2 antibody tests targeting the nucleocapsid or spike were compared to evaluate the characteristics and differences of each test. In addition, we would like to analyze the trend of changes in the antibody index of patients over time and their clinical significance. From June 2020 to November 2020, residual serum samples were collected from patients with confirmed/indeterminate results of COVID-19 molecular tests. Confirmed COVID-19 cases were defined as those that tested positive for SARS-CoV-2 RNA using real-time reverse transcription-polymerase chain reaction (RT-PCR) testing of combined nasopharyngeal and throat swab samples. Indeterminate cases were defined as patients with Ct values between 35 and 40. For patients with confirmed/indeterminate COVID-19, possible follow-up residual samples were also collected, and samples with insufficient quantities were excluded. A total of 126 specimens were collected from the 23 patients. For all specimens, 0.3 mL was aliquoted into microtubes and stored at -70˚C before testing. The median number of samples per patient was 6.0 (95% CI = 3.35-6.0), and the median follow-up period was 17 days (95% CI = [15] [16] [17] [18] [19] [20] [21] . This study was approved by the Institutional Review Board (IRB) of Kangnam Sacred Heart Hospital of Hallym University (IRB No. 2020-08-004-003). Since the anonymity of personal information was maintained, the need for informed consent was waived. The SARS-CoV-2 antibody was measured using three automated serological chemiluminescence immunoassays. The Alinity SARS-CoV-2 IgG reagent (06R86) from Abbott (IL, USA), Access SARS-CoV-2 IgG reagent (C58961) from Beckman Coulter (CA, USA), and Atellica SARS-CoV-2 Total (IgG + IgM) reagents (11206711 COV2T) from Siemens (IL, USA) were utilized in the study. The characteristics of each test are presented in Table 1 . Each of the three tests was performed according to the principle of chemiluminescent microparticle immunoassay (CMIA) and chemiluminescence immunoassay (CLIA), and the target site was the nucleocapsid for Alinity and spike for Access and Atellica. The cut-off indices for each positive immunoassay were 1.4, 1.0, and 1.0, respectively. Pearson's correlation coefficient was used to analyze the correlation between multiple SARS--CoV-2 antibody tests and clinical features. The degree of correlation was weak for values belonging to the range 0.10 � r <0.30, moderate for values of 0.30 � r <0.50, and strong correlation for r � 0.50, as previously guided [9] . The Mann-Whitney U test was conducted to evaluate the statistical significance of the difference in clinical aspects according to the SARS--CoV-2 IgG S/CO value. Statistical analyses were performed using SPSS version 24 (IBM Corporation, New York, NY) and MedCalc version 18 (MedCalc Software, Mariakerke, Belgium). Of the 23 patients enrolled in the study, 5 with a severe clinical course and 18 with no severe clinical course were divided into two groups and compared. Patients with severity were defined as those who showed pneumonia and had been intubated at least once during hospitalization and used a ventilator. Table 2 summarizes the laboratory test results and demographic data at the time of admission. In the severe patient group, the median age was 72.0 years (Interquartile range (IQR): 70.8-77.3), which was statistically significantly higher than that of the non-severe group (63.5 years, IQR: 59.0-72.0). Underlying diseases, including hypertension and diabetes, were present in all patients in the severe group. In the non-severe group, nine participants were healthy, and the remaining nine had underlying diseases. Two (40.0%) patients in the severe patient group died. There was no statistically significant difference between the complete blood count (CBC) and chemistry panel performed at the time of in the severe group and significantly higher than 18.3 mg/dL (IQR: 2.9-55.7) in the non-severe group. The median values of the SARS-CoV-2 S/CO index at admission, measured using three antibody test kits, were 0.37, 0.46, and 0.57, respectively. Hepatitis serology (HBsAg, anti-HBs, and anti-HCV), RPR test for syphilis, and HIV antibody information on the day of hospitalization were investigated. None of the patients were positive for syphilis, HIV, or HCV; 12 (52.2%) patients were positive for anti-HBs, while one patient tested positive for HBsAg. Alinity was tested in all specimens out of a total of 126 specimens. Access was tested in 123 specimens, and Atellica was tested in 120 specimens. When measured by Alinity, a total of 93 samples (73.8%) were positive, and 33 samples (26.2%) were negative. In the case of Access, 93 samples (73.8%) were positive, 29 samples (23.0%) were negative, and one sample (0.8%) (Fig 1) . Alinity, Access, and Atellica showed strong correlations with each other (Fig 2) . For the value of Pearson' s correlation coefficient r, Alinity and Access were 0.725 (P < 0.001), Access and Atellica 0.6997 (P < 0.001), and Alinity and Atellica were 0.854 (P < 0.001). Fig 3 shows the number of positive and negative samples for SARS-CoV-2 antibody measured with the three immunoassays over time from the onset of symptoms. Specimens collected after 21 days were positive for all the equipment. Two specimens were negative between and 16 and 20 days, one of which was negative only in Alinity, and the other was negative in all three devices. In this patient, seroconversion was observed on the 12 th day, but the tests performed on the 18 th day showed negative results (S1 Fig, Patient 13 ). Comparison of three chemiluminescence immunoassays for SARS-CoV-2 Of the 126 specimens, 121 were tested with all equipment, and 11 (8.7%) showed discrepancies. Table 3 provides additional information on specimens showing inconsistent results. Three specimens were negative only in Alinity, and all of them were collected from one patient (Patient 7) on the 9 th , 12 th , and 16 th days after symptom onset. In this patient, specimens at 1, 2, and 5 days of symptoms presented were all negative by the three instruments (Fig 4A) . In patient 11, only the specimens measured by Access were equivocal, and the other two instruments showed positive results (Fig 4B) . On the contrary, in patient 12, the results that were positive in the other two devices were negative only in Access (Fig 4C) . In both cases, the samples were measured three days after symptom onset, which corresponds to the early stage of Table 3 . Patients showed discrepancy in SARS-CoV-2 antibody positivity in three automated immunoassay system. For these samples, the median value of the S/CO index measured by Atellica was 0.65, which was close to the cut-off value. The samples measured with the other two instruments also showed a median index of 2.26, which did not deviate much from the cut-off value. In the case of patient 18, only Atellica, which measures the total antibody, was positive ( Fig 4D) on day 12 th . Comparison of three chemiluminescence immunoassays for SARS-CoV-2 Statistically significant moderate negative correlations were observed for calcium (r = -0.371, P < 0.001), total protein (r = -0.439, P <0.001), albumin (r = -0.578, P < 0.001), and hemoglobin (r = -0.386, P < 0.001). We analyzed the statistical differences in the antibody index values according to disease severity, underlying disease, and mortality for each instrument (Fig 6) . The SARS-CoV-2 IgG antibody measured by Alinity and Access showed significantly higher values in patients with severity (7.79 vs. 5.32, P = 0.0002 for Alinity, 89.69 vs. 31.17, P = 0.0005 for Access) than that in non-severe patients. In addition, Access to SAR-CoV IgG showed a statistically significantly higher value in patients with underlying disease (P = 0.039) and statistically significantly higher values in the deceased patients (P = 0.023). In the enrolled patients in this study, antibody index was maintained or gradually increased in 14 patients (73.7%) during the study period from 4 to 45 days per patient. Of a total of 23 patients, four with fewer than three follow-up specimens were excluded, and the dynamics of SARS-CoV-2 antibody measured with three instruments for 19 patients are described in the S1 Fig. Patients 2, 8, 10 , 17, and 23 showed severe symptoms and demonstrated increased antibody index values that lasted from 16, 8, 11, 7 , and 8 days after the onset of symptoms to discharge from the hospital, respectively. Meanwhile, three patients (Patient 4, 10, and 14), from the onset of symptoms to the time of discharge, showed sustained positive antibody index in all devices. Among them, Patient 4 was positive for HBsAg. In contrast, in five patients, the antibody index decreased during the measurement period. In patients 11, 13, and 20, the antibody levels decreased on the 12 th , 15 th , and 20 th days from symptom onset, respectively. Patients 17 and 18 showed a pattern of decrease on the 21 st and 7 th days, respectively, and then increased again on the 42 nd and 14 th days. Patients showed. In this study, the SARS-CoV-2 antibody, which is currently emerging worldwide, was measured using three automated chemiluminescence immunoassays, and the clinical significance of the antibody index was analyzed. The three types of immunoassay instruments had a strong correlation with each other and showed a concordance rate of 91.3%. In addition, the quantitative index was significant as a biomarker, reflecting the severity of the patient's clinical manifestations. After the pandemic of SARS-CoV-2 infection, the dynamics and performance of the SARS-CoV-2 antibody have been actively studied [10] [11] [12] [13] . However, we have limited information, and the results often show inconsistencies. In addition, there are few studies on the correlation between the clinical features of patients and the results of various laboratory tests, including the SARS-CoV-2 antibody. According to a study by S Phipps et al., the antibody index values of IgG and IgM for SARS-CoV-2 cannot reflect or predict disease severity [14] . Gozalbo et al. reported that the SARS-CoV-2 spike protein receptor-binding domain IgG antibody titer and neutralizing antibody levels measured by ELISA were less associated with proinflammatory biomarkers [15] . On the other hand, in the study of antibody dynamics conducted by Chen et al., SARS-CoV-2 IgG measured by two chemiluminescence devices showed high quantitative values in patients with pneumonia [16] . Liu and Zhao et al. have also reported that critical patients show higher titers of antibodies [17, 18] . It is considered that differences in quantification methods, specifically disparity in precision, range, and linearity of quantification, could be one of the causes of these discrepancies. In general, it has been reported that CLIA has higher specificity and accuracy than quantitative methods such as ELISA and agglutinin for the detection of many viruses [19] [20] [21] . The quantitative values calculated by automated chemiluminescence instruments could be more consistent and wider than those measured by ELISA in earlier studies and would achieve a better correlation with clinical features. There are few studies on the quantification of SARS-CoV-2 antibody using the CLIA or CMIA method so far; as such, more studies on the accuracy and clinical significance of quantitative values should be conducted. With the equipment used in this study, a pilot study of precision tests was performed with SARS-CoV-2-positive control reagent for three instruments and revealed a coefficient of variation percentage for Alinity of 1.5%, Access 2.80%, and Atellica 3.73%. In the follow-up study, a precise evaluation of the equipment and comparison of performance through more specimens should be performed. The three automated chemiluminescence equipment showed a correlation of 0.700-0.854 with each other, and when analyzing the results showing inconsistency, the discrepancy rate was 8.7%. Among the possible causes of inconsistency, the specimens classified as positive or negative with a quantitative value near the cut-off at the seroconversion period accounted for the most (Patients 8, 15, 21, and 23). Additionally, there was one patient who could not detect the antibody only in the Alinity test, the only device that had a different target protein (Patient 7). Finally, one patient was positive only in the Atellica device. Since this device measures total antibodies, including IgG and IgM, it was assumed that in this patient, IgG was negative and IgM was positive (Patient 18). Regarding the severity of illness in patients in this study, Alinity and Access (measuring for SARS-CoV-2 IgG antibody index), showed a statistically significant correlation, but Atellica (measuring for total antibody index) did not show the same. Measurement of total antibody presented better sensitivity and specificity compared to other immunoassays in previous studies [22] . Therefore, the Atellica SARS-CoV2 Total assay is considered to be more useful as a supplemental assay for diagnosis of SARS-CoV-2 than factors associated with clinical severity. The strength of this study is that serial follow-up for a relatively long period of time was possible in each patient. The dynamics of the SARS-CoV-2 antibody quantification value over time have been studied with a lot of interest in relation to individual immunity. In this study, 73.7% of patients during the follow-up period, antibody values were either maintained or increased. In 26.3% of patients, antibody index began to decrease on average after 15.4 days (95% CI = 7.61-23.2), and some of these patients showed a pattern of increasing again. In the case of Patient 4, all equipment showed positive SARS-CoV-2 antibodies from the 3 rd day to the 20 th day of symptoms. The patient was characteristically HBsAg-positive. Previously, the SARS-COV-2 antibody test showed false positives in acute infection [23, 24] . In particular, acute HBV infection showed cross-reactivity with the SARS-CoV-2 antibody assay in 75% of patients. This study also provides an example that HBsAg can cause false-positive results in various automated immunoassays. The other two patients (Patients 10 and 14) also showed high index-positive values throughout the hospitalization period, but the cause could not be determined. Follow-up studies will be needed to characterize patients with sustained or rapidly decreased in antibody index. In addition, many papers have been published on the clinical implications of target proteins in the detection of SARS-CoV-2 antibodies. Sun et al. reported that consistently high nucleotide proteins are associated with disease progression or severe illness, and spike protein has a protective effect on prognosis [25] . However, in this study, a rough estimate of the immunoassay results for each target protein can be measured due to the use of different equipment. The limitation of this study was the small number of enrolled patients. Nevertheless, it was possible to collect multiple serial samples for each patient, with a follow-up period of a minimum of three days to a maximum of 45 days. In particular, a relatively large number of patients were recruited at the initial stage of symptoms, so the seroconversion period was included in 87.0% of patients. The second limitation of this study was that the quantitative scale was different for each device. In particular, it is difficult to quantitatively compare each target protein. Therefore, it must be considered in the comparative analysis of each device, and as a follow-up study, precise target protein studies using a certain quantitative measurement tool would be required. As the cumulative number of patients with SARS-CoV-2 infection increases and long-term management is required, the importance of diagnosis, as well as the appropriate care and recovery of patients with high severity, are emphasized. As can be seen from the results of this study, the SARS-CoV-2 antibody has a significant correlation with clinical severity and is an important index reflecting the clinical characteristics of each patient. In particular, the S/CO index value obtained through automated equipment is expected to be actively used in the future as a quantitative value that can be obtained quickly and easily in clinical practice. Comparison of Clinical Features of COVID-19 vs Seasonal Influenza A and B in US Children Pulmonary fibrosis and COVID-19: the potential role for antifibrotic therapy. The Lancet Respiratory medicine Defining Association between COVID-19 and the Multisystem Inflammatory Syndrome in Children through the Pandemic COVID-19 mortality in patients with cancer on chemotherapy or other anticancer treatments: a prospective cohort study Clinical infectious diseases: an official publication of the Infectious Diseases Society of America Interpreting Diagnostic Tests for SARS-CoV-2 Profile of specific antibodies to SARS-CoV-2: The first report The Architecture of SARS-CoV-2 Transcriptome Useful effect size interpretations for single case research. Behavior therapy Antibody tests for COVID-19 Evaluation of two automated and three rapid lateral flow immunoassays for the detection of anti-SARS-CoV-2 antibodies Assessment of SARS-CoV-2 serological tests for the diagnosis of COVID-19 through the evaluation of three immunoassays: Two automated immunoassays (Euroimmun and Abbott) and one rapid lateral flow immunoassay (NG Biotech) Evaluation of Two Chemiluminescent and Three ELISA Immunoassays for the Detection of SARS-CoV-2 IgG Antibodies: Implications for Disease Diagnosis and Patients' Management SARS-CoV-2 Antibody Responses Do Not Predict COVID-19 Disease Severity SARS-CoV-2 antibodies, serum inflammatory biomarkers and clinical severity of hospitalized COVID-19 patients Multicenter evaluation of two chemiluminescence and three lateral flow immunoassays for the diagnosis of COVID-19 and assessment of antibody dynamic responses to SARS-CoV-2 in Taiwan. Emerging microbes & infections Patterns of IgG and IgM antibody response in COVID-19 patients. Emerging microbes & infections Clinical infectious diseases: an official publication of the Infectious Diseases Society of America Comparative Evaluation and Measure of Accuracy of ELISAs, CLIAs, and ECLIAs for the Detection of HIV Infection among Blood Donors in China Comparison of chemiluminescence immunoassay, enzyme-linked immunosorbent assay and passive agglutination for diagnosis of Mycoplasma pneumoniae infection Comparing Assay Performance of ELISA and Chemiluminescence Immunoassay in Detecting Antibodies to Hepatitis B Surface Antigen Performance characteristics of five immunoassays for SARS-CoV-2: a head-to-head benchmark comparison. The Lancet Infectious diseases High Incidence of False-Positive Results in Patients with Acute Infections Other than COVID-19 by the Liaison SARS-CoV-2 Commercial Chemiluminescent Microparticle Immunoassay for Detection of IgG Anti-SARS-CoV-2 Antibodies Rapid roll out of SARS-CoV-2 antibody testing-a concern Kinetics of SARS-CoV-2 specific IgM and IgG responses in COVID-19 patients. Emerging microbes & infections We thank Abbott Diagnostics, Siemens Healthiness, and Beckman Coulter Inc. for providing SARS-CoV-2 IgG/Total test kit in this study. Conceptualization: Nuri Lee, Seri Jeong, Wonkeun Song.