key: cord-0909336-bfcclrzp authors: Cantú, Victor J; Sanders, Karenina; Belda-Ferre, Pedro; Salido, Rodolfo A; Tsai, Rebecca; Austin, Brett; Jordan, William; Asudani, Menka; Walster, Amanda; Magallanes, Celestine G.; Valentine, Holly; Manjoonian, Araz; Wijaya, Carrissa; Omaleki, Vinton; Aigner, Stefan; Baer, Nathan A; Betty, Maryann; Castro-Martínez, Anelizze; Cheung, Willi; De Hoff, Peter; Eisner, Emily; Hakim, Abbas; Lastrella, Alma L; Lawrence, Elijah S; Ngo, Toan T; Ostrander, Tyler; Plascencia, Ashley; Sathe, Shashank; Smoot, Elizabeth W; Carlin, Aaron F; Yeo, Gene W; Laurent, Louise C; Manlutac, Anna Liza; Fielding-Miller, Rebecca; Knight, Rob title: Sentinel Cards Provide Practical SARS-CoV-2 Monitoring in School Settings date: 2022-02-02 journal: bioRxiv DOI: 10.1101/2022.02.01.478759 sha: 1e86b0bb422d60f41c6fe476293ef69749187323 doc_id: 909336 cord_uid: bfcclrzp Accurate, high-resolution environmental monitoring of SARS-CoV-2 traces indoors through sentinel cards is a promising approach to help students safely return to in-person learning. Because SARS-CoV-2 RNA can persist for up to a week on several indoor surface types, there is a need for increased temporal resolution to determine whether consecutive surface positives arise from new infection events or continue to report past events. Cleaning sentinel cards after sampling would provide the needed resolution, but might interfere with assay performance. We tested the effect of three cleaning solutions (BZK wipes, wet wipes, RNase Away) at three different viral loads: “high” (4 x 104 GE/mL), “medium” (1 x 104 GE/mL), and “low” (2.5 x 103 GE/mL). RNAse Away, chosen as a positive control, was the most effective cleaning solution on all three viral loads. Wet wipes were found to be more effective than BZK wipes in the medium viral load condition. The low viral load condition was easily reset with all three cleaning solutions. These findings will enable temporal SARS-CoV-2 monitoring in indoor environments where transmission risk of the virus is high and the need to avoid individual-level sampling for privacy or compliance reasons exists. Importance Because SARS-CoV-2, the virus that causes COVID-19, persists on surfaces, testing swabs taken from surfaces is useful as a monitoring tool. This approach is especially valuable in school settings, where there are cost and privacy concerns that are eliminated by taking a single sample from a classroom. However, the virus persists for days to weeks on surface samples, so it is impossible to tell whether positive detection events on consecutive days are persistent signal or new infectious cases, and therefore whether the positive individuals have been successfully removed from the classroom. We compare several methods for cleaning “sentinel cards” to show that this approach can be used to identify new SARS-CoV-2 signals day to day. The results are important for determining how to monitor classrooms and other indoor environments for SARS-CoV-2 virus. indoor surface types, there is a need for increased temporal resolution to determine 49 whether consecutive surface positives arise from new infection events or continue to 50 report past events. Cleaning sentinel cards after sampling would provide the needed 51 resolution, but might interfere with assay performance. We tested the effect of three 52 cleaning solutions (BZK wipes, wet wipes, RNase Away) at three different viral loads: 53 "high" (4 x 10 4 GE/mL), "medium" (1 x 10 4 GE/mL), and "low" (2.5 x 10 3 GE/mL). RNAse 54 Away, chosen as a positive control, was the most effective cleaning solution on all three 55 viral loads. Wet wipes were found to be more effective than BZK wipes in the medium 56 viral load condition. The low viral load condition was easily reset with all three cleaning 57 solutions. These findings will enable temporal SARS-CoV-2 monitoring in indoor 58 environments where transmission risk of the virus is high and the need to avoid 59 individual-level sampling for privacy or compliance reasons exists. 60 61 Importance 62 Because SARS-CoV-2, the virus that causes COVID-19, persists on surfaces, testing 63 swabs taken from surfaces is useful as a monitoring tool. This approach is especially 64 valuable in school settings, where there are cost and privacy concerns that are 65 eliminated by taking a single sample from a classroom. However, the virus persists for 66 days to weeks on surface samples, so it is impossible to tell whether positive detection events on consecutive days are persistent signal or new infectious cases, and therefore 68 whether the positive individuals have been successfully removed from the classroom. 69 We compare several methods for cleaning "sentinel cards" to show that this approach 70 can be used to identify new SARS-CoV-2 signals day to day. The results are important 71 for determining how to monitor classrooms and other indoor environments for SARS-72 CoV-2 virus. 73 74 Body 75 For the last two years, the SARS-CoV-2 pandemic has disrupted lives and caused 76 millions of deaths globally. Due to the high risk of virus transmission in indoor settings, 77 schools have been forced to convert to remote learning [1] . Although remote learning 78 can be convenient for some, not every child has access to a stable internet connection 79 and a supportive, quiet learning environment [2,3]. Therefore, most child health Samples were collected by swabbing the sentinel cards pre-inoculation, post-106 inoculation, and post-wipe (Supplemental Fig. S1) . 107 108 For this study we used three viral loads: "high" (4 x 10 4 ), "medium" (1 x 10 4 ), and "low" 109 To continue benchmarking proven environmental pipelines [7, 9, 11] and to account for 121 potential interactions, we used a factorial study design covering two swabbing media 122 (SDS, VTM), three cleaning solutions (BZK wipes, wet wipes, RNase Away) and three 123 viral spike-in concentrations (High, Medium, Low). Each condition was performed in 124 triplicate for a total of 54 cards. A three-step swabbing process was performed on each 125 card over a five-day period. First, we swabbed each card at the start of the day (Step 1). 126 Next, the viral spike-in was added to the card and a second swab was collected (Step 127 2). The card was then wiped with the cleaning solution and a final swab was collected 128 (Step 3). Extraction and RT-qPCR were performed as described in our previous work, 129 with VTM samples processed by the Perkin-Elmer pipeline and SDS samples 130 processed by the Thermo pipeline described in that work [PHL paper] . 131 Our results demonstrated that all of the cleaning methods worked well at low viral load 133 over 5 cleaning cycles, although cleaning failures were somewhat more frequent with 134 BZK (Fig. 1) . Wet wipes and BZK performed well with SDS at medium viral loads, but 135 only wet wipes performed well with VTM under these conditions. At high viral loads, only the combination of RNase away and SDS was able to remove the signal. Therefore, we 137 recommend that if high viral loads (Cq < 30, with SDS) are detected on a sentinel card, 138 that the sentinel card be replaced at the next opportunity rather than cleaned. Repeat 139 cleaning did not degrade the sentinel card surface or the ability to detect signal. As 140 expected from our past work [11] , SDS returned lower Cq values (better signal) than 141 VTM on the same samples. 142 An important consideration is the number of distinct genes recovered as matching in the 144 RT-qPCR process, as this can make the difference between a sample being called as 145 SARS-CoV-2 positive versus invalid. Because the peaks with the same viral load 146 applied were highly reproducible across multiple days (reaching the same height in Fig. 147 1), for this analysis we could treat each day as a replicate of the pre-application, post-148 application, and post-cleaning sample conditions that were collected on each day. Fig. 2 149 shows the reproducibility of replicates with cleaning, including the number of genes 150 amplified. Under low load conditions, as expected, cleaning was effective and non-zero 151 values occurred nearly always post-application and disappeared on cleaning, with the 152 exception of VTM samples which sometimes carried over (right hand column in Fig 2) . 153 In contrast, in the high load condition (left hand column in Fig. 2) , cleaning was nearly 154 always ineffective except with RNase Away, not practical for classroom use. In the 155 medium condition (middle column), all cleaning methods were effective with SDS but 156 none were effective with VTMthe slightly higher cluster of Cq values are obtained with 157 VTM in each case, consistent with expectations and with Fig. 1 . Because VTM is 158 viscous and contains fetal calf serum, a noticeable film developed on the sentinel cards, and we suspect that vigorous and repeated cleaning beyond what is achievable with 160 wipes may be required to remove all of it. 161 162 Taken together, these results indicate that sentinel cards are an effective and practical 163 solution for SARS-CoV-2 classroom monitoring, but that they must be cleaned carefully 164 in order to remove carryover signal, and this process is easier with samples collected in 165 SDS than in VTM (although cleaning with VTM is still possible). Because removing high 166 viral load from sentinel cards is challenging, strong positives should be removed rather 167 than cleaned. These findings are an important step to deployment of these cards at 168 scale in projects such as SASEA. 169 170 K-12 Virtual Schooling, COVID-19, and 172 Student Success COVID-19, school closures, and child poverty: a 174 social crisis in the making Addressing Racial and Ethnic Disparities 176 in COVID-19 Among School-Aged Children: Are We Doing Enough? Preventing 177 chronic Guidance for Education in K-12 Educational Settings. Children's Hospital of Philadelphia In the long shadow of our best intentions: Model-based assessment of the 182 consequences of school reopening during the COVID-19 pandemic Surveillance and Automated Reporting System Enable Early Detection of Nearly 187 85% of COVID-19 Cases on a University Campus Analysis of SARS-CoV-2 RNA Persistence 195 across Indoor Surface Materials Reveals Best Practices for Environmental 196 Monitoring Programs. mSystems 6 SARS-CoV-2 Distribution in Residential Housing Suggests COntact Deposition 204 and Correlates with Rothia sp Wastewater and surface monitoring to detect 212 COVID-19 in elementary school settings: The Safer at School Early Alert project. 213 medRxiv : the preprint server for health sciences 214 Indoor Dust as a 217 Matrix for Surveillance of COVID-19 Implementation of Practical Surface SARS-CoV-2 Surveillance in School Settings 225 Figure 1 . Effect of cleaning solution at high, medium and low viral load with different 228 swabbing media. On each day, three samples were taken: (1) before addition of viral 229 particles, (2) after addition, and (3) after cleaning. Therefore, the expected pattern is a 230 train of 5 spikes, starting at zero, rising to the maximum Cq value, returning to zero the 231 same day, and staying at zero until the next day, as seen for SDS in the low load 232 condition with RNase away (bottom right panel, solid lines). High, medium, and low 233 viral load were defined as (4 x 10 4 ), (1 x 10 4 ), and (2.5 x 10 3 ), respectively. Average Cq 234 (Avg. Cq) was calculated as a mean Cq value from three samples. Two viral transport 235 media were tested: SDS (0.5% w/v sodium dodecyl sulfate (SDS) and VTM (Viral 236 Transport Medium). Effective cleaning reset Cq for each day. RNase away was shown 237to be effective at each viral load, whereas benzalkonium chloride (BZK) and wet wipes 238were only effective at medium and low viral load. was performed in three steps: initial virus amount (blank) was sampled from the wall for 244Step 1. Virus was deliberately loaded on the surface and sampled for Step 2. The 245 surface was cleaned with different cleaning methods and sampled for qPCR analysis for 246Step 3. High, medium, and low viral load were defined as (4 x 10 4 ), (1 x 10 4 ), and (2.5 x 247 10 3 ), respectively. Average Cq (Avg. Cq) was calculated as a mean Cq value from three 248 samples. Two viral transport media were tested: SDS (0.5% w/v sodium dodecyl sulfate 249 (SDS) and VTM (Viral Transport Medium). Effective cleaning reset Cq for each day 250 (steps 1 and 3), whereas ineffective cleaning retained high viral load (non-zero Cq) at 251 these steps. The number of gene hits refers to how many gene targets were amplified 252 during RT-qPCR across the triplicate samples: the qPCR method for the SDS samples 253 targeted 3 genes for a total of 9 possible genes amplified while the method for the VTM 254 samples targeted 2 genes for a total of 6 possible gene hits.