key: cord-0908572-5wqulymt authors: Dakay, Katarina; Cooper, Jared Blaine; Greisman, Jacob D.; Kaur, Gurmeen; Al-Mufti, Fawaz; Gandhi, Chirag D.; Santarelli, Justin G. title: Flow diversion in anterior cerebral artery aneurysms date: 2021-12-21 journal: Brain Circ DOI: 10.4103/bc.bc_49_21 sha: b9f2ba3ddbf53380119d145a6d9604299396bb30 doc_id: 908572 cord_uid: 5wqulymt INTRODUCTION: Anterior cerebral artery (ACA) aneurysms are commonly encountered in clinical practice but can be challenging to treat. Flow diversion is a viable treatment in this population. METHODS: We retrospectively evaluated patients treated at our center from May 2017 to December 2020 who underwent flow diversion for an ACA aneurysm at or distal to the anterior communicating artery (ACOM). We defined ACA aneurysms as any aneurysm involving the ACOM itself, at the junction of the ACA with the ACOM (A1/A2), or in distal A2/A3 branches; both ruptured and unruptured aneurysms were included. Baseline and follow-up clinical and angiographic data were collected; the primary measure was elimination of the aneurysm on follow-up angiogram. Patients underwent flow diversion with a Pipeline stent. A single flow diverting stent was placed in the dominant ACA spanning from the A2 segment extending into the A1 segment; two patients required H-pipe technique. Distal aneurysms were treated with a single Pipeline device deployed across the parent vessel, covering the aneurysm. RESULTS: Two-seven patients underwent a total of 28 flow diversion procedures; median age was 57 and 16 (59.3%) were male. Thirteen (48.2%) patients presented with subarachnoid hemorrhage; of these, four were treated within 6 weeks of the index hemorrhage. Most patients (22; 81.5%) had significant ACA asymmetry. There was one postoperative intracerebral hemorrhage and one groin complication. Follow-up data were available for 19 patients, 15 (78.9%) of which showed no residual aneurysm and 17 (89.5%) had protection of the dome. CONCLUSION: Flow diversion of ACA aneurysms can be a primary treatment modality in an unruptured aneurysm or a complement to initial coil protection of a ruptured aneurysm. Further studies are needed to confirm these results. T he anterior cerebral artery (ACA) is a common location for aneurysm formation, particularly at the anterior communicating artery (ACOM); the latter has been shown to confer a higher risk of rupture as compared to other locations in the anterior circulation; [1, 2] thus, treatment is often offered for smaller, unruptured aneurysms. It has been suggested that treatment should be offered for unruptured anterior communicating aneurysms measuring >4 mm, [3] in the absence of complicating factors. Endovascular coiling is commonly employed in the treatment of intracranial aneurysms; however, coil embolization can be technically challenging in many cases due to small aneurysm dome size, presence of multiple perforating vessels, and superior or posterior dome orientation. [4, 5] Stent-assisted coiling may allow for placement of coils in broad-based aneurysms, however, is associated with a higher treatment morbidity than coiling alone. [5] Flow diversion, which allows for redirection of flow away from the aneurysm and through the treated parent vessel, leads to gradual endothelialization and thrombosis with subsequent occlusion of the aneurysm. Flow diversion has been well described in the treatment of proximal anterior circulation aneurysms [6] but is less studied for more distal aneurysms such as those affecting the circle of Willis and ACOM complex. We describe a single-center case series of patients who underwent flow diversion for ACOM aneurysms at our center. We retrospectively evaluated all patients treated at our center from May 2017 to December 2020 who underwent flow diversion for an ACA aneurysm. The study was approved by the Westchester Medical Center Institutional Review Board. We defined ACA aneurysms as any aneurysm involving the ACOM itself, at the junction of the ACA with the ACOM (A1/ A2), or in distal A2/A3 branches; both ruptured and unruptured aneurysms were included. We collected baseline clinical and demographic data and angiographic data from both pre-and posttreatment imaging when available; the primary measure was complete occlusion of the aneurysm on follow-up angiogram, defined as no residual filling of either neck or dome of the aneurysm. Parent vessel stenosis and peri-procedural complications were collected as secondary outcomes. Patients underwent flow diversion with a Pipeline stent under general anesthesia; the procedure was performed under transfemoral access with an 8Fr 45 cm sheath using the Cook shuttle (Cook Medical) as the guide catheter, with the Phenom Plus (Medtronic) as the intermediate and the Phenom 027 microcatheter (Medtronic) for distal access. The Navien (Medtronic) intermediate catheter was used in lieu of the Phenom Plus in a minority of cases. A single flow diverting stent was placed in the dominant ACA spanning from the A2 segment extending into the A1 segment in a majority of cases; one case utilized two stents for an H-pipe technique. Patients with an azygous ACA or absence of one of the A1 segments were not treated with Pipeline due to the necessity of preserving flow across the ACOM in this instance. Aneurysms distal to the ACOM were treated with a single Pipeline device deployed across the parent vessel, covering the aneurysm. Patients with ruptured aneurysms were treated with flow diversion on a delayed basis several weeks after the subarachnoid hemorrhage after initial coiling to protect the rupture point; patients must have had serial CTs demonstrating resolving/stable hemorrhage, discontinuation of their external ventricular drain, and angiographic runs must demonstrate no evidence of significant parent vessel vasospasm prior to flow diversion treatment. Patients with large or significant hematoma volume received treatment in a delayed fashion, several days or weeks after the initial hemorrhage, at the discretion of the treating neurosurgeon. We defined treatment within the acute to early subacute window as within 6 weeks of the causative subarachnoid hemorrhage; data regarding hydrocephalus and vasospasm incidence were collected for these patients. Admitted patients receiving flow diversion as an adjunctive treatment for a previously ruptured aneurysm were typically given a loading dose of 650 mg of aspirin and 300 mg of clopidogrel at least 12 h prior to the procedure; patients being treated electively began taking 325 mg of aspirin and 75 mg of clopidogrel beginning 5-7 days prior to the procedure. Intraoperative assays (VerifyNow) were checked prior to placement of the flow diverting stent to ensure therapeutic status. Dual antiplatelet therapy was continued for a minimum of 6 months following the flow diverting stent, with longer courses for patients with evidence of intimal hyperplasia or stenosis on their follow-up angiogram. Follow-up angiogram was performed at approximately 6 months after flow diversion treatment, with a second follow-up angiogram at 1 year posttreatment. Occlusion was defined as no evidence of residual filling of either the dome or neck of the aneurysm and collected as a binary variable. Complete occlusion was defined as no filling of the aneurysm on arterial, capillary, or venous phases. The aneurysm was considered protected if there was either complete occlusion or filling confined to an entry remnant, defined as a trace neck remnant with no filling of the body or dome. Residual aneurysmal filling was assessed on both the ipsilateral and the contralateral internal carotid artery angiogram. A total of 28 procedures were performed on 27 patients during the study period [ Table 1 ]. The median age was 57 and 16 were male. Thirteen patients presented with subarachnoid hemorrhage, and 14 were unruptured. Of the patients with ruptured aneurysms, four were treated within the acute to early subacute period, which we defined as within 6 weeks of the causative subarachnoid hemorrhage; time to treatment ranged from 1 day to 49 days with a median of 19.5 days. The remainder of the patients were treated >6 weeks from the subarachnoid hemorrhage, with a median time to treatment of 141 days (range, 91-203). Of the 4 patients with ruptured aneurysms who were treated in the acute to early subacute period, two developed symptomatic vasospasm which was medically managed in both cases without the need for angioplasty. Two patients required an external ventricular drain on admission; however, neither patient required permanent cerebrospinal fluid diversion. Both patients who required an external ventricular drain were treated with flow diversion only after successful weaning and removal of the drain. The median aneurysm size was 4 mm, with a range from 1.5 to 15 mm. Most patients had significant ACA asymmetry with a significant caliber difference between the A1 segments (22; 81.5%). In most cases of asymmetry, the left A1 was dominant. Thirteen patients (48.2%) had been previously treated with aneurysmal recurrence or residual. In 25 (92.6%) patients, a single flow diverting stent was utilized; one patient underwent bilateral A2 to A1 Pipeline utilizing the "H-pipe" technique on the initial procedure and a second patient underwent staged H-pipe treatment. Procedural success was achieved in 100% of patients. There was one peri-operative access site complication requiring surgical intervention. There was one peri-operative case of intracerebral hemorrhage (ICH) that was managed by decompressive craniectomy and hematoma evacuation. No cases of intraoperative thrombosis or stroke were observed. Of 27 patients, one patient was lost to follow-up and one patient died after a prolonged hospital course. Six patients were pending follow-up angiogram at the time of this manuscript. Follow-up angiogram data were available for 19 patients [ Table 2 ], with a median time of 7.5 months. Due to the COVID-19 pandemic, follow-up angiogram was delayed in some patients. Of the 19 patients, 15 (78.9%) patients exhibited complete elimination of the aneurysm and 17 (89.5%) had protection of the dome; an example is provided in Figure 1 . Of the four patients with residual filling, one had a relatively larger sized aneurysm measuring 9 mm and one underwent a fairly early follow-up angiogram at 3 months postflow diversion. The third patient had a complex pericallosal A2/A3 aneurysm with trace, static neck residual on the last follow-up angiogram. Finally, one patient continued to have filling from the contralateral ACA. The patient who underwent staged H-pipe treatment had successful complete occlusion of the aneurysm on follow-up angiogram. Six patients demonstrated mild narrowing/intimal hyperplasia of the parent vessel on follow-up angiogram; however, no patients had hemodynamically significant stenosis or occlusion of the parent vessel on follow-up. There were no reported cases of interval subarachnoid hemorrhage following Pipeline treatment to date to the time of writing this manuscript. Flow diversion can be a durable and effective treatment for ACA aneurysms. Advantages of this method as primary treatment include avoiding the risk of microcatheterization of small aneurysms, which entails a rupture risk, particularly in aneurysms with a small dome. [7] In addition, the use of a flow diverting stent avoids the risk of coil compaction or migration and allows for the treatment of aneurysms which may not otherwise be amenable to coiling due to broad-necked or irregular morphology. Flow diversion can be useful as a treatment for recurrent or residual aneurysms after coiling; in patients with previously ruptured aneurysms where coil embolization may have been incomplete due to preservation of branches or perforators, flow diversion can be employed as a delayed treatment to eliminate the aneurysm. Major considerations associated with flow diversion include the need for dual antiplatelet therapy for several months as well as lifelong aspirin; in patients who present initially with rupture, we waited a period of several weeks prior to flow diverting a remnant or recurrent aneurysm until the risk of dual antiplatelet therapy was felt to be acceptable. In addition, there is a risk of in-stent stenosis or thrombosis; while we observed no cases of procedure-related stroke or occlusion in our series, we did observe nonflow limiting intimal hyperplasia in a minority of patients which was asymptomatic in all cases. One patient in our series developed a periprocedural neurological complication (ICH). The 7.4% overall complication rate, and 3.7% neurological complication rate observed in our cohort is consistent with other literature regarding the use of the Pipeline device for treating aneurysms in general with neurological complication rates mostly in the range of 5%-13.5%. [5] Considerations specific to the ACOM location include the possibility that the aneurysm may continue to fill through the contralateral ACA. We have generally observed that flow diversion is more likely to be successful in aneurysms that are located at the A1-A2 junction or asymmetrically rather than true ACOM aneurysms; however, one series found that only 13% of ACOM aneurysms were true ACOM aneurysms and most occurred at the A1-A2 junction. [8] We did not treat patients with azygous ACAs with this treatment modality, as in that case preserving flow across the ACOM was imperative. In general, the contralateral, uncovered A1 segment will typically increase in prominence on the follow-up angiogram, such that each A1 segment supplies its ipsilateral territory without relying on substantial cross-flow across the ACOM. In the case of true ACOM aneurysms, it may be more likely that patients require a second, contralateral flow diversion procedure to completely eliminate the aneurysm. Our 100% successful deployment rate, comparable to other studies, supports the technical feasibility of the Pipeline device to treat ACOM and distal ACA aneurysms. Furthermore, the Pipeline device was used as the initial treatment modality in 14 of the 27 aneurysms treated. Therefore, our results suggest that not only is the Pipeline device a feasible treatment for ruptured and unruptured aneurysms but that it should be considered as a first-line treatment modality for unruptured cases. Previous series of Pipeline flow diverters for ACOM aneurysms report complete occlusion rates ranging from 25% to 100% [ Table 3 ]; [9] [10] [11] [12] [13] [14] [15] [16] [17] other flow diverters such as the Silk and p64 have also been utilized in the management of ACOM aneurysms. Meta-analyses of ACA and ACOM flow diversion treatments including various commercially available flow diverters have reported a 79% occlusion rate at the last follow-up. [18, 19] To date, we report that none of the 27 patients included in this study experienced recurrent subarachnoid hemorrhage after Pipeline treatment, regardless of angiographic outcome as occluded or revealing stasis with residual filling. Consistent with prior literature, delayed Pipeline-related complications are unlikely. Therefore, even in the absence of complete occlusion, our results suggest a protective effect conferred by Pipeline device treatment, preventing future rupture and subarachnoid hemorrhage. Our study is limited in that it is a single-center, retrospective series; additionally, some patients were pending follow-up at the time of this manuscript. However, this series adds to the literature demonstrating the feasibility and safety of treating ACOM aneurysms with the Pipeline flow diverting stent. Aneurysms of the anterior communicating complex and distal ACA are common but can be technically difficult to achieve complete and stable coil occlusion given their size, multiple perforators and branches in close proximity, and angulation. Flow diversion has well-documented technical success for treatment of recurrent or uncoilable proximal anterior circulation aneurysms but is less studied in aneurysms of the ACA. In our single-center series, we demonstrate that flow diversion of ACA aneurysms can be a durable and effective treatment for recurrent or residual ruptured aneurysms, as well as a primary treatment for unruptured aneurysms. Further follow-up and additional studies are needed to confirm these results. As this was a retrospective study, written informed consent was not required. Nil. There are no conflicts of interest. Natural history of unruptured intracranial aneurysms: A long-term follow-up study The natural course of unruptured cerebral aneurysms in a Japanese cohort Risk of rupture of small anterior communicating artery aneurysms is similar to posterior circulation aneurysms Angiographic outcome after endovascular therapy for anterior communicating artery aneurysms: Correlation with vascular morphological features Safety and effectiveness of microsurgical clipping, endovascular coiling, and stent assisted coiling for unruptured anterior communicating artery aneurysms: A systematic analysis of observational studies Pipeline for uncoilable or failed aneurysms: 3-year follow-up results Endovascular therapy of very small aneurysms of the anterior communicating artery: Five-fold increased incidence of rupture Are anterior communicating aneurysms truly anterior communicating aneurysms? An observational study Flow diversion treatment of anterior communicating artery region aneurysms Treatment of complex anterior cerebral artery aneurysms with Pipeline flow diversion: Mid-term results Pipeline endovascular device for the treatment of intracranial aneurysms at the level of the circle of Willis and beyond: Multicenter experience Endovascular flow diversion for treatment of anterior communicating artery region cerebral aneurysms: A single-center cohort of 50 cases Rescue treatment with pipeline embolization for postsurgical clipping recurrences of anterior communicating artery region aneurysms Periprocedural complications of second-generation flow diverter treatment using Pipeline Flex for unruptured intracranial aneurysms: A systematic review and meta-analysis Anterior communicating artery aneurysm treatment with the pipeline embolization device: A single-center experience with long-term follow-up Flow diversion treatment of aneurysms of the complex region of the anterior communicating artery: Which stent placement strategy should "I" use? A single center experience Flow diversion treatment of complex bifurcation aneurysms beyond the circle of Willis: A single-center series with special emphasis on covered cortical branches and perforating arteries Flow-diversion treatment of unruptured saccular anterior communicating artery aneurysms: A systematic review and meta-analysis Treatment of anterior cerebral artery and anterior communicating artery aneurysms with flow-diversion devices: A systematic review and meta-analysis