key: cord-0906988-2u9m3thk authors: Sberna, Giuseppe; Lalle, Eleonora; Capobianchi, Maria Rosaria; Bordi, Licia; Amendola, Alessandra title: Letter of concern re: “Immunochromatographic test for the detection of SARS-CoV-2 in saliva. J Infect Chemother. 2021 Feb;27(2):384-386. doi: 10.1016/j.jiac.2020.11.016.” date: 2021-04-13 journal: J Infect Chemother DOI: 10.1016/j.jiac.2021.04.003 sha: 33410ba4e7c8da0f95806ab0a9b27d79a3620e33 doc_id: 906988 cord_uid: 2u9m3thk nan Letter of concern re: "Immunochromatographic test for the detection of SARS-CoV-2 in saliva. J We read with great interest the paper by Kashiwagi et al. [1] , showing that 7/16 saliva samples resulted positive by RT-PCR test using N2 probe according to the manual provided by Japan National Institute of Infectious Diseases; among these, only 4 showed the presence of SARS-CoV-2 antigen using the ESPLINE® SARS-CoV-2 (Fujirebio Inc., Tokyo) [2]. The Authors infer that the sensitivity of the antigen test depends on the RNA-copy concentrations and is lower than that previously reported [3] [4] [5] . We report our experience on the ESPLINE® SARS-CoV-2 antigen test that was obtained on a higher number of saliva samples and, indeed, the results obtained in our laboratory indicate for this sample matrix a clinical sensitivity even lower than that reported in this paper. We first evaluated the analytical sensitivity of ESPLINE® SARS-CoV-2 assay by using a pool of fresh saliva samples, collected by passive drooling from healthy donors and spiked with known concentrations of 2019-nCoV/Italy-INMI1 isolate [5, 6] . Data obtained from multiple replicates of serial dilutions of the isolate were used to calculate the low limit of detection (LOD) of the assay by Probit analysis using the MedCalc statistical software (MedCalc Software Ltd, Ostend, Belgium). The LOD resulting from this analysis was 2.99 (CI: 2.83-3.69) TCID 50 /mL, corresponding to 6.60 (CI 6.43-7.29) Log RNA cp/mL ( Figure 1 ). However, when stratifying samples into groups based on ranges of RT-PCR cycle threshold (Ct, an indirect indicator of viral RNA concentration), the antigen-positives samples were mostly associated with low Ct values, therefore high viral loads (Table 2) . if measures are not taken to alleviate these drawbacks. Immunochromatographic test for the detection of SARS-CoV-2 in saliva Development of rapid lmmunochromatographic enzyme lmmunoassay for SARS-CoV-2 nucleocapsid protein Saliva is more sensitive for SARS-CoV-2 detection in COVID-19 patients than nasopharyngeal swabs Saliva as a non-invasive specimen for detection of SARS-CoV-2 Frequency and Duration of SARS-CoV-2 Shedding in Oral Fluid Samples Assessed by a Modified Commercial Rapid Molecular Assay. Viruses Molecular characterization of SARS-CoV-2 from the first case of COVID-19 in Italy The authors report no declarations of interest