key: cord-0906869-n4g4ae28 authors: Liu, Y.; Ye, H.; Huynh, H.; Kang, P.; Xie, C.; Kahn, J. S.; Qin, Z. title: Single-Particle Counting Based on Digital Plasmonic Nanobubble Detection for Rapid and Ultrasensitive Diagnostics date: 2021-02-23 journal: medRxiv : the preprint server for health sciences DOI: 10.1101/2021.02.18.21252027 sha: 94cc2ca9833c91b0c6c532dc2dc4087f7967495b doc_id: 906869 cord_uid: n4g4ae28 Rapid and sensitive diagnostics of infectious diseases is an urgent and unmet need as evidenced by the COVID-19 pandemic. Here we report a novel strategy, based on DIgitAl plasMONic nanobubble Detection (DIAMOND), to address these gaps. Plasmonic nanobubbles are transient vapor bubbles generated by laser heating of plasmonic nanoparticles, and allow single-particle detection. Using gold nanoparticles labels and an optofluidic setup, we demonstrate that DIAMOND achieves a compartment-free digital counting and works on homogeneous assays without separation and amplification steps. When applied to the respiratory syncytial virus diagnostics, DIAMOND is 150 times more sensitive than commercial lateral flow assays and completes measurements within 2 minutes. Our method opens new possibilities to develop single-particle digital detection methods and facilitate rapid and ultrasensitive diagnostics. The ability to rapidly detect diseases with high precision is of paramount importance as evidenced by the current COVID-19 pandemic (1, 2) . Digital assays have been a remarkable conceptual advance over the past two decades due to their single-molecule detection and absolute quantification (3, 4). They partition the analytes into microwells or emulsion droplets as 5 small compartments for independent signal amplification and digital counting, leading to the sensitivity enhancement by up to 10 3 -fold over the conventional assays (i.e., enzyme-linked immunosorbent assay and polymerase chain reaction) (3, 4) . Despite those advantages, digital assays have suffered from complex assay operations. Such paradigms prompt further innovations that develop various digital sensing platforms based on micro/nano-particles (5-7). With its 10 capability of examining individual particles' changes upon recognizing target molecules, singleparticle detection holds great potential to simplify digital assays (8-10). Examples of singleparticle digital assays include bright/dark-field imaging (11), interferometric (12) or fluorescent imaging (13, 14) , surface-enhanced Raman scattering (15), surface plasmon resonance microscopy imaging (16), and particle mobility tracking (17) (18) (19) . However, current techniques 15 rely on cumbersome particle purification and advanced imaging that inevitably limit their widespread use. Herein, we report a novel strategy for simplified single-particle digital assay based on DIgitAl plasMONic nanobubble Detection (DIAMOND, see Table S1 for comparison with other assays). Plasmonic nanobubbles (PNBs) refer to the vapor bubbles generated by short laser pulse 20 excitation of plasmonic nanoparticles (NPs) and amplify their intrinsic scattering for the detection by a secondary probe laser (20- 24) . They have lifetime that lasts nanoseconds and are sensitive to the physical parameters of NPs such as sizes, shape, concentration, and clustering state (20-22). Taking advantage of these unique properties, we designed an optofluidic setup to flow the NP suspension in a micro-capillary ( Fig. 1A and Fig. S1 ). The focused laser beam 25 probes a microscale "virtual compartment" of about 16 pL and detects the PNB generation from single particles. Since PNBs are transient events, there is no cross-talk between laser pulses, which allows "on" and "off" signal counting in a compartment-free manner (Fig. 1B) . We demonstrated robust single NP counting and sensitive detection of large particles in a strong background of small particles (1 in 240). We then implemented DIAMOND in a homogeneous 30 assay that uses plasmonic gold NPs (AuNPs) as labels without additional separation or amplification steps. Using silica (SiO 2 ) beads as targets, we demonstrated that DIAMOND has sub-femtomolar detection limit and provides absolute quantification. When applied to detect respiratory syncytial virus (RSV), DIAMOND provided a 150-fold sensitivity enhancement over the state-of-the-art lateral flow assay (LFA) and sample-to-answer time within 2 minutes. 35 Therefore, DIAMOND opens new possibilities to develop separation-, amplification-, and compartment-free single-particle digital assays and facilitate rapid and ultrasensitive diagnostic platforms. We first evaluated the ability of DIAMOND for single NP detection. Serial aqueous dilutions 40 of 75 nm AuNP (as characterized in Fig. S2, 3 and Table S2 ) were prepared for the DIAMOND tests. For simplicity, we converted the particle concentration into the expected average number (λ) of AuNPs per detection zone. Fig. 2A and Fig. S4 show the representative testing results and the corresponding Poisson distributions for the given λ , respectively. Due to the variation of actual AuNP number (k) per detection zone, it led to discrete PNB signals with fluctuated intensity. In the case of λ =0.04, the positive PNB signals could be satisfactorily discriminated from the baseline ( Fig. 2A) . According to the Poisson statistics, each of signal drop refers to a single AuNP being detected (Fig. S4D) , confirming the capability of DIAMOND in single-NP detection. To correlate the PNB signals with AuNP concentration, we calculated the frequencies (f) of positive PNB signals in each trace as "on" signals and plotted the f on as a function of λ 5 (Fig. 2B) . A high correlation coefficient (R 2 =0.998) indicates the AuNP quantification by counting the frequency of "on" signal. Furthermore, we found a linear relationship (slope=1.012, R 2 =0.999, Fig. 2C ) between the theoretical probability (P) predicted by Poisson statistics and the experimental f on , suggesting that DIAMOND is a calibration-free technique and allows absolute quantification. 10 Next, we used DIAMOND to detect AuNPs of different sizes under the same concentration. AuNP suspensions of 15 nm, 35 nm, 50 nm, and 75 nm (Fig. S2, 3 and Table S2 ) were prepared for the test. Fig. 2D shows the representative PNB signal traces. Due to the large number of AuNPs per detection zone (λ=240), consistent PNB signals were observed in each laser pulse. Fig. 2E shows representative PNB signals taken from each case and suggests that larger NP size 15 leads to larger PNB signals. To quantify this relationship, we extracted the values of amplitude and area-under-the-curve (AUC) from each PNB signal (Fig. S5 ) and plotted their distribution profiles as a function of AuNP sizes (Fig. 2F) . They could be fitted with 1.98-and 3.51-order dependences to the NPs' size, respectively. This seems to agree with the fact that the PNB generation is related to the amount of heat generation and absorption cross-section of AuNPs 20 (25, 26) . The good fitting indicates the accurate size determination by measuring the amplitude and AUC of PNB signals. We then evaluated the ability of DIAMOND for heterogeneity identification in a population of NPs. 15 nm and 75 nm AuNP suspensions and their mixture were tested. Fig. 3A shows the representative PNB signal traces taken from those samples. The large intensity variation of PNB 25 signals observed in the mixture sample is due to the addition of 75 nm AuNPs. To sort those specific signals resulting from 75 nm AuNPs as heterogeneities, we developed a three-step analysis protocol. Firstly, we extracted the amplitude and AUC values of each PNB signal as indexes for quantification. Fig. 3B shows the corresponding results in bivariate, where each scatter represents a single PNB signal. Secondly, we fitted normal distributions to the amplitude 30 and AUC of 15 nm AuNPs as a reference and calculated the threshold (T) as 5 standard deviations (σ) above the mean (μ). As such, the two thresholds covered over 99.9% of the scatters (Fig. 3B, case i) . Lastly, assigning the thresholds to the mixture sample allows data sorting, where the scatters above the thresholds refer to the positive or "on" PNB signals resulting from co-existence of 15 nm and 75 nm AuNPs and vice versa (Fig. 3B, case ii) . For a 35 direct comparison, we calculated the frequencies of "on" signals (f on ) from 75 nm AuNPs alone (Fig. 3B , case iii) and benchmarked them with the Poisson probability. The agreement between experimental result and theoretical prediction (Fig. 3C) indicates that our method provides accurate and absolute quantification of large NPs from a strong background of small ones (i.e., 1 in 240). Clearly, DIAMOND is able to detect heterogeneity without additional separation step. 40 We further evaluated the feasibility of implementing DIAMOND for the homogeneous assay. Homogeneous assays are simple and one-step sensing methods that require minimal sample handling and are therefore promising for rapid detection (28) . To validate our hypothesis in a model system, we used the AuNPs as probes to detect SiO 2 beads (Fig. 4A ). Fig. 4B shows the transmission electron microscopy (TEM) image of the as-prepared product, where a core-satellites structure was formed with AuNPs fully covering the surface of SiO 2 beads. Fig. 4C shows representative PNB signal traces and Fig. 4D shows the bivariate plot taken from serial assay solutions. Similarly, the thresholds (T=μ+5 σ ) of amplitude and AUC were calculated from the control group (highlighted in dashed lines) and assigned for "on" signal counting. The f on were then plotted as a function of λ for SiO 2 beads (Fig. 4E) . A linear relationship (R 2 =0.99) 5 in the range of 0.0016-0.16 was observed and the limit of detection (LOD) was calculated to be 0.0028, equivalent to 1.75×10 5 mL -1 or 290 aM (inset of Fig. 4E ). Such a detection limit is ~570fold lower than the colorimetric detection (Fig. S6) . Furthermore, DIAMOND allows absolute quantification for homogeneous assays, as indicated by the linear correlation (slope=0.995, R 2 =0.99) between the background-subtracted frequency (f on ') and the Poisson probability ( Fig. 10 Finally, we applied DIAMOND for the rapid detection of RSV. RSV is the major respiratory pathogen that accounts for up to 74,500 deaths in 2015 globally in children below age 5 (28). We chose Synagis (Palivizumab) as the detection antibody and conjugated it on the AuNPs through 3,3'-dithiobis (sulfosuccinimidyl propionate, DTSSP) as a crosslinker (Fig. S7) . The as-prepared 15 probes could specifically target the fusion proteins on the RSV surface at the room temperature and were ready for detection (Fig. 5A ). Fig. 5B shows TEM images of AuNP-based probes associated with RSV particles, indicating effective probe binding with the target. Fig. S8 and For a direct comparison, we benchmarked the homogeneous immunoassay against the commercially available LFA kit for RSV, which has an LOD of 1.6×10 4 PFU/mL (Fig. S9 , BinaxNOW, Abbott). We then carried out DIAMOND for RSV detection. Following the same protocol as discussed above, we set the thresholds based on the control group (Fig. 5D) and 25 assigned them for f on counting (Fig. 5E) . In particular, a linear relationship (R 2 =0.995) in the range of 10 2 -10 4 PFU/mL was observed and the LOD was calculated to be 108 PFU/mL (inset of Fig. 5E ). Evidently, DIAMOND achieved a sensitivity enhancement of ~333-fold over the colorimetric result of homogeneous immunoassay and ~150-fold over the commercial LFA. To demonstrate the potential clinical use, we applied DIAMOND to quantify RSV in the 30 transporting medium used to collect nasal swab samples. RSV at concentrations of 500-4,500 PFU/mL (as measured by end-point titration in viral culture) was spiked in the medium for testing. As summarized in Table 1 , the recovery rate for DIAMOND in examining the five RSVspiked samples was calculated to be 94.4-119%. The coefficient of variation (CV, n=6) increased from ~6% to ~20% with decreasing RSV concentration, as expected when approaching the 35 LOD. These data demonstrated that the DIAMOND-coupled homogeneous immunoassay allows sensitive analysis of viral samples in complex matrices (i.e., transporting medium) and supports the potential applications in clinics. Since the PNB generation is dependent on the laser fluence, we can perform the DIAMOND 40 test in two modes by modulating the laser fluence above and below PNB generation threshold, referred to as above-and below-threshold modes. Specifically, the threshold of laser fluence (E) was defined as the 50% probability of PNB generation (P PNB ) as determined from the logistic regression ( Fig. S10) (20) . In principle, the below-threshold mode uses low laser fluence at P PNB =0% (red arrow), resulting in the generation of PNB signals from only the larger NPs or 45 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10.1101/2021.02.18.21252027 doi: medRxiv preprint clusters instead of the small NPs or monomers. Alternatively, the above-threshold mode utilizes high laser fluence at P PNB =100% (blue arrow) to activate all NPs for PNB generation. Despite the background-free signal counting, the below-threshold mode requires an additional step for the laser fluence calibration in order to avoid the incidents where the laser fluence is too low to generate PNB signals from the larger NPs or clusters. In the above-threshold mode, high laser 5 fluence leads to consistent PNB generation that can be visually determined without calibration. However, additional tests for the negative control sample as a reference are necessary to determine the threshold. This can be addressed by splitting the laser beams for simultaneous detection of positive and negative controls, and thus providing automated background-subtracted detection and internal control for validation. 10 In the digital assays, increasing the total counting number benefits the sensitivity enhancement and reduces the measurement error (6). In the DIAMOND platform, we can increase the data collection time, but this is a tedious way to acquire more data points (Fig. S11 and Table S3 ). Alternatively, we can use pulse laser with higher repetition rate. Considering the PNB's lifetime is at nanosecond range, we can use a pulsed laser with repetition rate up to 1 15 MHz (pulse interval = 1 microsecond). Also, we relied on the repetition rate and flow speed to generate independent PNB events. Taking all parameters (e.g., flow speed, laser diameter, repetition rate, and capillary size) into consideration, we calculated the sampling efficiency of current system is 20-40% along and 5-10% orthogonal to the flow direction, respectively (Fig. S12) . Such low sampling efficiencies greatly limit the number of detected events and lead to 20 Poisson noise and measurement error. Considering a repetition of 10-100 kHz, a micro-channel with a comparable size to the beam diameter and a faster flow speed, this would allow collecting million nanobubble signals within minutes. We envision that such optimizations may allow further improvements in the performance of DIAMOND in terms of the detection sensitivity and measurement uncertainty. 25 In summary, we have developed DIAMOND as a novel method for single-particle digital counting in a AuNP homogeneous assay. DIAMOND allows single NPs detection and identification of heterogeneity from a uniform population. Such capability makes DIAMOND a compartment-free digital counting platform and allows its implementation on homogeneous assays. Importantly, DIAMOND achieves enhanced detection sensitivity and completes tests 30 within minutes without additional steps, making it a highly promising platform for rapid and ultrasensitive diagnostics. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Figures S1-S14 Tables S1-S4 References (26, (29) (30) (31) (32) 20 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10.1101/2021.02.18.21252027 doi: medRxiv preprint All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. where N is the number of counted "on" signals. All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10.1101/2021.02.18.21252027 doi: medRxiv preprint independent measurements, and the LOD was calculated as 3 standard deviations of the control dividing the slope of regression line. (F) Correlation between the background-subtracted frequency (f on ') and Poisson probability (P). All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted February 23, 2021. ; https://doi.org/10.1101/2021.02.18.21252027 doi: medRxiv preprint A novel coronavirus outbreak of global health concern CRISPR-Cas12-based detection of SARS-CoV-2 nanobubble induced nanomechanical transduction Near-infrared light triggered-release in deep brain regions using ultra-photosensitive nanovesicles Thermophysical and biological responses of gold nanoparticle laser heating Quantitative comparison of photothermal heat generation between gold nanospheres and nanorods Tuning the gold nanoparticle colorimetric assay by nanoparticle size, concentration, and size combinations for oligonucleotide detection Global, regional, and national disease burden estimates of acute lower respiratory infections due to respiratory syncytial virus in young children in 2015: a systematic review and modelling study Turkevich method for 35 gold nanoparticle synthesis revisited One-step assay for detecting influenza virus using dynamic light scattering and gold nanoparticles