key: cord-0900685-p8r5iy9q authors: Ocagli, Honoria; Lorenzoni, Giulia; Lanera, Corrado; Schiavo, Alessandro; D’Angelo, Livio; Liberti, Alessandro Di; Besola, Laura; Cibin, Giorgia; Martinato, Matteo; Azzolina, Danila; D’Onofrio, Augusto; Tarantini, Giuseppe; Gerosa, Gino; Cabianca, Ester; Gregori, Dario title: Monitoring Patients Reported Outcomes after Valve Replacement Using Wearable Devices: Insights on Feasibility and Capability Study: Feasibility Results date: 2021-07-04 journal: Int J Environ Res Public Health DOI: 10.3390/ijerph18137171 sha: 5cf5914f00dceac7559d72693ca80f0f79ad9429 doc_id: 900685 cord_uid: p8r5iy9q Wearable devices (WDs) can objectively assess patient-reported outcomes (PROMs) in clinical trials. In this study, the feasibility and acceptability of using commercial WDs in elderly patients undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) will be explored. This is a prospective observational study. Participants were trained to use a WD and a smartphone to collect data on their physical activity, rest heart rate and number of hours of sleep. Validated questionnaires were also used to evaluate these outcomes. A technology acceptance questionnaire was used at the end of the follow up. In our participants an overall good compliance in wearing the device (75.1% vs. 79.8%, SAVR vs. TAVR) was assessed. Half of the patients were willing to continue using the device. Perceived ease of use is one of the domains that scored higher in the technology acceptance questionnaire. In this study we observed that the use of a WD is accepted in our frail population for an extended period. Even though commercial WDs are not tailored for clinical research, they can produce useful information on patient behavior, especially when coordinated with intervention tailored to the single patient. Use of consumer wearable devices (WDs) is increasing both in daily usage and in clinical trials [1] . Fuller et al. [1] , in a recent systematic review, showed that various brands of WDs were used in clinical studies, offering accurate measures for steps and heart rate. The International Data Corporation (IDC) reported a Year-Over-Year Growth of 35 .1% in 2020 in the global market of WDs [2] . In clinical setting, the introduction of WDs has brought new challenges to face. At first, the European Medicines Agency did not release any specific guidance addressing the use of WDs. While still recognizing the importance 2 of 13 of their use for drugs development, the appropriateness for a specific population, the validity of collected data and the management of large amounts of data collected through the device, issues concerning the choice of the suitable device depending on safety have emerged [3] . A recent US national survey on the use of wearable healthcare devices showed that 82.38% of the people involved in the study are willing to share their health data recorded by their WDs with their healthcare professionals [4] . The use of these technologies tends to decline with advancing age, although the elderly, especially those with a chronic disease, are one of the populations that could benefit most from continuous monitoring in their daily setting. The elderly, however, have poor knowledge on the use of WDs [5] . Various studies have investigated the impact of commercial WDs on the elderly. For example, WDs appear to be accurate in measuring step counts and activity duration in community-dwelling adults [6] and have a positive impact on health as their use had increased physical activity in obese patients [7] . Since WDs are often not tailored for the elderly [8] , it is important to evaluate their acceptability in their daily life. A study evaluating the acceptance of WDs among the elderly showed that they seem to accept them and understand the importance of their use in healthcare setting [9] . Patients-reported outcome measures (PROMs) have been suggested in literature to be integrated in clinical trials [10] , since clinical outcomes do not measure the patients' perception of their health status or functional being. The assessment of PROMs (i.e., physical function and quality of life), should be encouraged in elderly patients [11] . Physical function assessment can be useful for evaluating outcomes not directly related to the disease, but still relevant to maintaining personal dependence [12] . WDs can objectively assess physical function in daily clinical practice [13, 14] . High levels of physical function are essential for the success of cardiac procedures, so much so that ad hoc cardiac rehabilitation programs have been established to improve patients' functional recovery through exercise therapy [15] . In the available literature some trials have shown that, for example, after both transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR), physical function is improved. SAVR and TAVR are both highly valuable options for patients with heart failure (HF), a condition that affect mostly elderly patients as showed in a study on time trends in first hospitalization for HF in a community-based population [16] . Patients who had a higher level of physical function before the procedure showed more favorable trajectories [12] . Various studies have compared the two procedures in both high [17, 18] and low surgical risk patients [19] . In these studies, New York Heart Association (NYHA) score or, more often self-reporting questionnaire [12, 20, 21] were used to evaluate physical functions of these patients. However, these instruments have some limitations related to self-reporting, for example in recall and desirability biases. The present work aims to describe the feasibility of using WDs to monitor PROMs in patients who undergoing TAVR/SAVR enrolled in the run-in phase of the Capability study [22] . In this study, the feasibility and acceptability of using a commercial wearable device in elderly patients undergoing TAVR or SAVR will be explored. The study design characteristics and inclusion criteria are described elsewhere [22] . This is a multicenter prospective observational study, that enrolled patients undergoing SAVR and TAVR according to the evaluation of the local heart team since March 2018 at the University hospital of Padova and the hospital of Vicenza. Patients were enrolled at least one week prior to the procedure. Questions related to socio-demographic characteristics, risk factors, physical activity and clinical characteristics were the information collected at baseline assessment. WDs along with the smartphone were delivered at baseline assessment. Participants completed the same assessments, except for demographic characteristics, at one month, three months, six months and twelve months after the procedure. From March 2020 to the end of the follow up period, assessments were carried out only by telephone given the restrictions related to the COVID-19 pandemic. The study is registered in Clinicaltrials.gov (NCT03843320) and approved by the hospital ethics committee with the protocol No 943 (4 January 2019). Written informed consent was obtained from all patients for study participation and for data collection through their Garmin© device account after proper explanation of the study outcomes by a physician. A Garmin © Vívoactive ® 3 smartwatch activity tracker device and a smartphone with the Garmin Connect © application (GARMIN, Olathe, KS, U.S.) installed in the smartphone for data transfer were provided to each patient at baseline assessment. The device used in the study was commercially available and was chosen for its ability to estimate steps count and sleep duration in free living environments both in the general and elderly population [23] . Both the patient and his/her caregiver were provided with information and trained on the use of the WD and the smartphone. A personal account of the Garmin Connect © application has been created for each patient. The app contains only patient demographics (i.e., gender, age, weight, height, wrist of usage of the WD). Both the participants and their caregivers were not granted access to the account. All notifications were disabled in the device and the smartphone was cleaned by all the unrelated applications, to avoid affecting behaviors of the participants. Participants were asked to wear the device on their wrist 24 h a day, including while showering and sleeping, except while charging. They were asked to charge the device daily and sync data weekly. A member of the study assisted the patients at each of follow up for connectivity issues and for collecting data, while also remaining available by phone and possibly in person to troubleshoot the device at any time. Patients were also informed that they would be asked to return the device at the end of the study. However, at the last follow up, participants were asked to choose whether to continue using the device with the smartphone for private use. After the end of the study, we collected no further data from the device. Physical function was assessed through a series of standard and validated tests: Duke Activity Status Index (DASI) [24] , Activity of Daily Living (Barthel Index) and Instrumental Activity of Daily Living (IADL)). The DASI is a measure of functional capacity that can be obtained by self-administered questionnaire and already used in patients that underwent TAVR [25] . The Barthel Index (BI) evaluates activity of daily living [26] and has been used in aortic valve replacement [27] . The DASI score ranges from 0 to 58.2, Barthel Index ranges from 0 to 100, for both the instrument, the higher the score, the higher the functional status. IADLs were evaluated with the scale of Lawton and Brody [28] . The higher the score, the greater the person's abilities. The Epworth sleepiness scale (ESS) was used to evaluate the "subject's general level of daytime sleepiness" [29] , a higher score means higher sleepiness and could be interpreted as follows: 0-5 lower normal daytime sleepiness, 6-10 higher normal daytime sleepiness, 11-12 mild excessive daytime sleepiness, 13-15 moderate excessive daytime sleepiness, 16-24 severe excessive daytime sleepiness [30]. Compliance with the use of the WD (i.e., the time the device was worn) was determined by calculating the proportion of days the device was active and the total number of days before and after the procedure. At the end of the follow up, patients were given a questionnaire on technology acceptance, based on the work of Puri et al. [9] . The instrument investigated six key dimensions for WD acceptance: perceived usefulness, perceived ease of use, privacy concerns, perceived risks, facilitating conditions and equipment characteristics. Device acceptance was assessed with the question L33 as suggested in the validation study [9] , "Would you use the device you used during the last year to continue to monitor or track your physical activity or health?" Continuous variables were reported as I, II (median) and III quartiles, categorical variables were presented as absolute numbers and percentages. Wilcoxon's test and Chisquared test were used to evaluate differences between TAVR and SAVR, respectively, for continuous and categorical variables. The compliance on the use of the WDs was summarized computing the number of days before the procedure divided by the number of days that data was synchronized in that period, the same was carried out for the follow up period. Significance was evaluated for p-value lower than 0.05. Data analysis was performed with R software (version 4.0.3) [31] . The patients considered eligible for the study were 17, 12 TAVR and 5 SAVR, 4 from the center of Vicenza and the remaining from the University hospital of Padova. Eight patients completed the entire follow up period (Flowchart Figure 1 ) with an enrolment rate of 47%. Four patients were found to be ineligible after completion of the baseline assessment. Table 1 reports patients baseline demographic characteristics by type of procedure, TAVR or SAVR. The overall sample had a median age of 79 years, 78 in the SAVR group and 82 in the TAVR group (p-value = 0.046). Table 1 reports patients baseline demographic characteristics by type of procedure, TAVR or SAVR. The overall sample had a median age of 79 years, 78 in the SAVR group and 82 in the TAVR group (p-value = 0.046). Except for age, there were no statistically differences between the SAVR and the TAVR groups. Patients were mainly female (10, 59%), married or cohabiting (12, 71%). Hypertension was the main risk factors in both groups, (14, 82%). Only two patients underwent TAVR procedure in urgent status. Patients, according to clinical frailty scale were more than vulnerable in the TAVR group (4, 33%; vulnerable, 3, 25% mildly frail and, 2, 17% moderate frail). Ejection fraction was similar in the two groups, median of 60 and 58, respectively, in SAVR and TAVR (p-value 0.49). Table 2 reports the trend of the Barthel Index, DASI score, IADL index and ESS score at each follow up according to the type of procedure. SAVR patients reported higher physical function levels than TAVR especially at 12-month follow up (BI 100 vs. 85, DASI 19.9 vs. 12.8, respectively, for SAVR and TAVR). TAVR recorded lower levels of physical function at baseline according to the DASI score (30.4 vs. 14.4). Physical function level was similar at 12 months of follow up compared to the baseline assessment in both groups according to BI. The DASI score instead showed a decrease for both groups: 30.4 vs. 19.9 and 14.4 vs. 12.8, respectively, for SAVR and TAVR. As for the IADL, there was a decrease at 12 months from baseline both for TAVR and SAVR (6 vs. 4 for SAVR, 6 vs. 5 for TAVR). The ESS score was highest at 12 months follow up for both SAVR and TAVR, both groups had lower normal daytime sleepiness at each follow up. Rest heart rate trend recorded by the device according to procedure and baseline vs. follow-up period. Data in the box are the I, median and III quartile of rest heart rate. As for the number of steps, the SAVR group seems more active, median of 2701 steps/day vs. 1735 of TAVR (Figure 3) . Data were mainly synchronized by the caregivers in both groups, only one TAVR patient synchronized by himself the device. The WDs and the smartphones were charged mainly by the caregivers, two TAVR patients charged their devices themselves. None of the patients or their caregivers had used a wearable device prior to the study. The As for the number of steps, the SAVR group seems more active, median of 2701 steps/day vs. 1735 of TAVR (Figure 3) . Regarding the number of hours of sleep, both groups after the procedure had a similar median number of hours of sleep (7.3 SAVR vs. 7.0 TAVR) (Figure 4 ). Data were mainly synchronized by the caregivers in both groups, only one TAVR patient synchronized by himself the device. The WDs and the smartphones were charged mainly by the caregivers, two TAVR patients charged their devices themselves. None of the patients or their caregivers had used a wearable device prior to the study. The compliance, evaluated as the percentage of days device use divided by the total number of days, was similar in both groups and reached a median of 75.1% in SAVR and 79.8% in TAVR (Table 3) . Table 3 . Compliance on the use of the device according to the procedure, SAVR vs. TAVR. Data are reported as I quartile, median and III quartile, median and standard deviations. Overall Figure 5 shows an overview of WDs wear time for the entire study period. Valid and missing data days are showed for each participant. The percentages of missing data vary from 0, no data, up to 70.15%. Noticeably, the patients with only 0.55% and 0% of missing data were those who could rely on the daily assistance of the caregiver. Only one patient collected less than 30% of data: in this case the caregiver was not often in contact with the patient and the patient was not able to use the smartphone autonomously. collected less than 30% of data: in this case the caregiver was not often in contact with the patient and the patient was not able to use the smartphone autonomously. One patient, not reported in the analysis, stopped using the activity tracker before the surgery due to the tightness of the strap and the caregiver unwillingness to synchronize data. Missing data varied between 11.5% and 32.88%: in these cases, caregivers were available on a weekly basis. The patient who collected data by himself eventually reduced his compliance due to the long waiting-time for the surgery. In the preoperative period, SAVR patients synchronized data more often than TAVR ones, One patient, not reported in the analysis, stopped using the activity tracker before the surgery due to the tightness of the strap and the caregiver unwillingness to synchronize data. Missing data varied between 11.5% and 32.88%: in these cases, caregivers were available on a weekly basis. The patient who collected data by himself eventually reduced his compliance due to the long waiting-time for the surgery. In the preoperative period, SAVR patients synchronized data more often than TAVR ones, however this result could be affected by the difference in the length of the pre-operative period, which was longer for SAVR patients. In the follow up period, the compliance was similar on both groups, 75.1% vs. 75.9% for SAVR and TAVR, respectively. Table 4 reports the technology acceptance questionnaire scores for each of the seven dimensions based on the type of procedure. Except for perceived risk dimension (median 10 vs. 5.5 SAVR vs. TAVR, p-value = 0.016) there were no differences in all the dimensions among the two groups. The perceived risk dimensions score was higher in patients that underwent SAVR. Four patients reported that they would wish to continue to use the device (3 TAVR, 1 SAVR). The device characteristics satisfied the patients, the equipment characteristics reached for both group the maximum score, the same for perceived ease of use, also perceived usefulness showed good levels. Conversely, privacy concern (median 8 vs. 9, SAVR vs. TAVR), perceived risk (10 vs. 5 SAVR vs. TAVR) and subjective norm (10 vs. 9, SAVR vs. TAVR) showed lower level of satisfaction. Table 4 . Differences in the technology acceptance questionnaire scores per dimension according to the procedure for the overall sample. For each dimension is reported the maximum score. Data are reported as I, II and III quartiles. In parenthesis is reported the highest score for each dimension. Perceived usefulness ( This study explores the feasibility and acceptability of using a commercial wearable device in elderly patients undergoing TAVR or SAVR. The main findings of our study showed that there was an overall good compliance in wearing the device (75.1% vs. 79.8%, SAVR vs. TAVR) with half of the patients willing to continue using the device. Physical function decreased after both SAVR and TAVR, more in TAVR patients. The ESS score increased after the procedure but remained as "normal daytime sleepiness" according to the score, the WDs showed an increase in the number of hours slept up to 7 h per night for both groups. Our results showed a good overall acceptance of wearing the device during the follow up period. These results are in line with what was reported in a recent literature review which showed a high-level adherence in long term daily use [32] . The acceptance rate in our study was high compared to other studies using the same device [33] . Our results considered a longer follow up period. Studies in the literature, in order to evaluate the compliance and acceptance of a device, considered shorter periods ranging from a few days [34] to weeks [5] . The number of valid days in the follow up period was lower than in the study of Henriksen et al. [35] (265 vs. 292). This result is promising in our population as data synchronization was usually performed by a caregiver. However, this high compliance can be explained by the desire of the patients to use of the WD to contribute to the study. The main discomfort reported by our patients were related to the need to use another smartphone to synchronize data with the website and connectivity issues, as also reported in a review of activity trackers for senior citizens [36] . This could easily be avoided by allowing the patients or the caregiver to download the app directly to their own smartphone. Other technical problems were related to changing accidentally the setup of the WD or of the smartphone or forgetting to charge them. In one case, the main problem was related to the unavailability of a WI-FI connection at home. To solve these problems the presence of a technically skilled staff member available on request has proven to be a key point. Other studies showed that technical problems could reduce compliance in the use of WDs [37] . There is a growing interest in evaluating the acceptability of wearable devices both in the general and elderly population. A greater acceptance of these devices can improve the quality of real time data collection [38] . Various studies have shown that older adults accept the use of wearable devices, especially after facing acceptance barriers [9, 35, 39] . Perceived ease of use is one of the domains that has higher level in our results. This is in line with the findings of a recent study [40] and related to the fact that, while technology use has been increasing also in elderly people, they still need additional information and support to adopt it [41] . A recent study showed that commercial wearable devices are reliable for measuring physical activity level in elderly patients in real-life setting [42] . Despite this increase and the fact that elderly population is the one that can benefit the most from the use of these devices, especially when chronic illnesses are present [34] , very few elderlies currently use daily WDs [5] or consider them in health monitoring [43] . However, the perceived ease of use recorded with the questionnaire was high for both groups, respectively, median of 30 for SAVR and 32 points for TAVR (maximum 35). Even though the compliance was high, the perceived usefulness was not as high in both groups, median of 16 and 17, respectively, for SAVR and TAVR (64% and 68% of the overall score). This is likely sue to the fact that most of the device-related procedures were performed by caregivers and not by patients. During the follow up encounters, the researcher reinforced the importance of collecting data from the activity tracker. Caregivers, on the other hand, reported that having the possibility to see heart rate, number of steps and number of hours of sleep was useful for obtaining information on the health of the patient. Participants when asked How much would you be willing to pay for the device you wore during the last year? (question L35) answered mainly 0 euro (4, 50%), 2 from 1 to 50 euros and 1 from 51 to 100 euros. This contrasts with what Kekade [5] reported. This may be related to the fact that in our study the population was extremely elderly (median 78 and 82, respectively, for SAVR and TAVR), while the Kekade study considered elderly over 65 years of age. Cardiac rehabilitation after both TAVR and SAVR have shown improved functional capacity in a recent review [27] . A reduction in physical function level both according to BI and DASI score from baseline to one year follow up was showed in our sample. This result is in contradiction of what reported in other metanalysis for TAVR [21] and both TAVR and SAVR [12] . Cardiac rehabilitation was required only for two participants, both underwent SAVR. So, the sole adoption of the wearable devices is not enough to improve physical activity in these patients. In the future it would be useful to help patients in recognizing the long-term benefits of the device, along with social support as suggested by Kononova [44] in his study on tracker perceptions among older adults. Moreover, it would be helpful to use the commercial wearable activity tracker in a broader physical activity intervention as shown by the review of Brickwood [45] . Our data showed that patients that underwent SAVR were more active than TAVR patients. A functional decline or lack of improvement after the procedure was found, as already found by Kim in his study evaluating changes in functional status in the year after aortic valve replacement [12] . These differences between SAVR and TAVR and no change in functional status for TAVR may be related to the fact that TAVR group had a higher median age and none of them had rehabilitation after the procedure. The main limitations of this study derived from the difficulties to recruit patients with our strictly inclusion criteria. Moreover, the study design was adapted to the limitations derived from the spread of the pandemic of COVID-19. Given the importance of developing a proper observational study to evaluate the use of wearable devices in elderly patients that underwent TAVR or SAVR, our feasibility study provided useful insights on how to implement further our project. In this study we have observed that the use of a WD is accepted in our frail population for an extended period. The use of a WD for collecting data allows the collection of data on daily basis, directly at home, with improved quality since data does not have to be manually entered and checked. However, the use of WDs in clinical trials requires an additional effort on behalf of the research team. A researcher must be available to set up the device at the beginning of the study and to solve problems related to the device. The collection of data through a WD requires always to have an application for collecting data: this could cause problems related to connectivity and device communication. Moreover, the transmission of data requires a minimum ability in the use of technologies in participants. The help of a caregiver is required especially when participants are elderly and sometimes this is not possible. However, the presence of the device alone is not enough to encourage healthy behaviors. Therefore, it would be useful to create a coordinated intervention with a physiatrist to implement a physical activity program tailored to the single patient. As also reported in the literature, elderly people need more training session than young people, this is particularly true in population such as ours, who are not used to any type of electronic device. Considering that older people, especially frail ones, often rely on the help of a caregiver, they also need to be trained in the potential of these tools. Another suggestion could be the creation of custom reports to allow patients to view their progress in terms of physical activity. In our experience it would be faster to download the app directly on the smartphone of patients or assistants to avoid connectivity problems. Even though commercial wearable devices were not tailored for clinical research, they could produce useful information on the behavior of the patient. Furthermore, the implementation of the use of these devices, especially in elderly, will minimize the need to attend the clinical study center, with the potential of reducing the time and costs related to person-by-person visits. Funding: This research was funded by an unrestricted grant provided by Edwards Lifesciences. The funding body was not involved in the design of the study and collection, analysis and interpretation of data and in writing the manuscript. The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Ethics Committee of the hospital of Vicenza (protocol code 943, 4 January 2019). Informed consent was obtained from all subjects involved in the study. The data presented in this study are available on request from the corresponding author. The data are not publicly available due to privacy restrictions. The authors declare no conflict of interest. Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review Selection of and Evidentiary Considerations for Wearable Devices and Their Measurements for Use in Regulatory Decision Making: Recommendations from the ePRO Consortium Patterns of Use and Key Predictors for the Use of Wearable Health Care Devices by US Adults: Insights from a National Survey The usefulness and actual use of wearable devices among the elderly population The validity and reliability of consumergrade activity trackers in older, community-dwelling adults: A systematic review Randomized Trial of a Fitbit-Based Physical Activity Intervention for Women A review of physical activity monitoring and activity trackers for older adults. Stud. Health Technol User Acceptance of Wrist-Worn Activity Trackers Among Community-Dwelling Older Adults: Mixed Method Study The importance of patient-reported outcomes: A call for their comprehensive integration in cardiovascular clinical trials Beyond adding years to life: Health-related quality-of-life and functional outcomes in patients with severe aortic valve stenosis at high surgical risk undergoing transcatheter aortic valve replacement Evaluation of Changes in Functional Status in the Year After Aortic Valve Replacement A Systematic Review of Wearable Patient Monitoring Systems-Current Challenges and Opportunities for Clinical Adoption Wearable Devices in Clinical Trials: Hype and Hypothesis Cardiac rehabilitation after transcatheter versus surgical prosthetic valve implantation for aortic stenosis in the elderly Time trends in first hospitalization for heart failure in a community-based population Transcatheter aortic valve implantation for aortic stenosis in high surgical risk patients: A systematic review and meta-analysis A comparison of transcatheter aortic valve implantation and surgical aortic valve replacement in 1,141 patients with severe symptomatic aortic stenosis and less than high risk Meta-Analysis of Transcatheter Versus Surgical Aortic Valve Replacement in Low Surgical Risk Patients Patients' self-reported function, symptoms and health-related quality of life before and 6 months after transcatheter aortic valve implantation and surgical aortic valve replacement Functional capacity and health-related quality of life outcomes post transcatheter aortic valve replacement: A systematic review and meta-analysis Using Wearable Devices to Monitor Physical Activity in Patients Undergoing Aortic Valve Replacement: Protocol for a Prospective Observational Study Validity Evaluation of the Fitbit Charge2 and the Garmin vivosmart HR+ in Free-Living Environments in an Older Adult Cohort A brief selfadministered questionnaire to determine functional capacity (the Duke Activity Status Index) Chronic obstructive pulmonary disease in patients undergoing transcatheter aortic valve implantation: Insights on clinical outcomes, prognostic markers, and functional status changes Functional evaluation: The Barthel Index Cardiac rehabilitation programme after transcatheter aortic valve implantation versus surgical aortic valve replacement: Systematic review and meta-analysis Assessment of older people: Self-maintaining and instrumental activities of daily living A new method for measuring daytime sleepiness: The Epworth sleepiness scale R: A Language and Environment for Statistical Computing Data management and wearables in older adults: A systematic review A feasibility study of an unsupervised, pre-operative exercise program for adults with lung cancer Acceptance of Commercially Available Wearable Activity Trackers Among Adults Aged Over 50 and With Chronic Illness: A Mixed-Methods Evaluation Succeeding with prolonged usage of consumer-based activity trackers in clinical studies: A mixed methods approach A Review of Activity Trackers for Senior Citizens: Research Perspectives, Commercial Landscape and the Role of the Insurance Industry Determinants for Sustained Use of an Activity Tracker: Observational Study A Systematic Review of Wearable Sensors and IoT-Based Monitoring Applications for Older Adults-A Focus on Ageing Population and Independent Living Older Adults' Acceptance of Activity Trackers Comparison of Older and Younger Adults' Attitudes Toward the Adoption and Use of Activity Trackers Technology for Behavioral Change in Rural Older Adults with Obesity Assessment of Physical Activity in the Elderly Population: Usability and Accuracy of a Smartwatch A Systematic Review on the Use of Wearable Body Sensors for Health Monitoring: A Qualitative Synthesis The Use of Wearable Activity Trackers Among Older Adults: Focus Group Study of Tracker Perceptions, Motivators, and Barriers in the Maintenance Stage of Behavior Change Consumer-Based Wearable Activity Trackers Increase Physical Activity Participation: Systematic Review and Meta-Analysis