key: cord-0899712-kee84yus authors: De Rienzo, Mafalda; Foddai, Maria Laura; Conti, Laura; Mandoj, Chiara; Iaboni, Stefano; Saladini, Ilenia; Castilletti, Concetta; Matusali, Giulia; Donno, Davide Roberto; Marchioni, Luisa; Ianniello, Stefania; Corpolongo, Angela; Palange, Maria; Ciliberto, Gennaro; Piaggio, Giulia; De Marco, Federico title: Long-Term Persistence and Relevant Therapeutic Impact of High-Titer Viral-Neutralizing Antibody in a Convalescent COVID-19 Plasma Super-Donor: A Case Report date: 2021-08-23 journal: Front Immunol DOI: 10.3389/fimmu.2021.690322 sha: b3b01c71a27cd1092de8f092b6a144587bbca455 doc_id: 899712 cord_uid: kee84yus A convalescent, non-severe, patient with COVID-19 was enrolled as a hyper-immune plasma voluntary donor by the Immuno-Hematology and Transfusion Unit of the Regina Elena National Cancer Institute in Rome, under the TSUNAMI national study criteria. During a nearly 6-month period (May–October 2020), the patient was closely monitored and underwent four hyperimmune plasma collections. Serum SARS-CoV-2 (anti-S + anti-N) IgG and IgM, anti-S1 IgA, and neutralizing titers (NTs) were measured. Anti-SARS-CoV-2 antibody levels steadily decreased. No correlation was found between anti-S/anti-N IgG and IgM levels and viral NT, measured by either a microneutralization test or the surrogate RBD/ACE2-binding inhibition test. Conversely, NTs directly correlated with anti-S1 IgA levels. Hyperimmune donor plasma, administered to five SARS-CoV-2 patients with persistent, severe COVID-19 symptoms, induced short-term clinical and pathological improvement. Reported data suggest that high NTs can persist longer than expected, thus widening hyperimmune plasma source, availability, and potential use. In vitro RBD/ACE2-binding inhibition test is confirmed as a convenient surrogate index for neutralizing activity and patients’ follow-up, suitable for clinical settings where biosafety level 3 facilities are not available. IgA levels may correlate with serum neutralizing activity and represent a further independent index for patient evaluation. Since the initial outbreak of a novel coronavirus emerged in Wuhan, China, in December 2019 (1) , the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) proved to be highly pathogenic and caused nearly 200 million cases of the related coronavirus disease 2019 (COVID- 19) , which was associated with high mortality, largely exceeding 4 million cases by 10 th July 2021 (2) . Although widely investigated, the immune response to SARS-CoV-2 and its impact on the course of COVID-19 and outcome is still not fully understood. As successful protection against clinical disease and severe outcomes could be obtained by passive immunity, a great deal of research is focusing on neutralizing Abs and convalescent plasma (CP). Neutralizing Abs are known to be associated with protective immunity against secondary infection with SARS-CoV-2 in nonhuman primates (3, 4) . Based on this rationale, COVID CP (CCP) has been proposed and used in severe, life-threatening cases and for compassionate use (5) and a number of human neutralizing monoclonal Abs have been shown to reduce the viral load in patients without an immune response at baseline (6) , and are now available for clinical evaluation (7, 8) . Currently, the use of hyperimmune plasma is limited by a number of critical issues, including little knowledge about the persistence of post-COVID-19 immunity in convalescents, lack of a consensus on a potential donor's eligibility criteria, and a lack of standardized methods to quantitate the specific anti-SARS-CoV-2 humoral immunity. Regarding this last pivotal issue, a great number of different methods and technical approaches have been devised to measure the immune response of COVID-19, while the Ab kinetics and their pathological and prognostic relevance remain poorly understood (9) (10) (11) (12) . In addition, commercially available enzyme immunoassays could have a low accuracy to detect neutralizing titers (NTs) suitable for hyperimmune plasma donation, although they are endowed with high diagnostic accuracy to detect anti-SARS-CoV-2 Abs (13, 14) . Here, we report on a CCP donor whose NT persisted adequate to plasma transfer longer than 155 days after clinical healing, despite the total anti-SARS-Cov-2 IgG levels that steadily declined. Five patients with severe COVID-19 received hyperimmune plasma from this donor with beneficial effects. The in vitro receptor-binding domain (RBD)/ACE2-binding inhibition test (RABI test) proved a reliable surrogate assay for NT evaluation of candidate donor screening in the clinical setting. Finally, we deem it important to report that, as far as the reported case is concerned, anti-COVID-19-S1-protein IgA represents a relevant contributor to neutralizing activity. Clinical information on six patients diagnosed with COVID-19 was obtained from clinical charts. One patient was admitted to the "A. Gemelli" University Hospital, in Rome, and became a plasma donor once convalescent. Five patients were admitted to INMI and transfused with plasma from the above-mentioned donor. Retrieved information ( Table 1 ) included the following: demographic data, day of admission since symptom onset and presenting symptoms; temperature, the ratio of partial pressure arterial oxygen and the fraction of inspired oxygen (PaO 2 /FiO 2 ), SOFA score, clinical complications, and outcome; laboratory data included white blood cell count, lymphocyte count, liver and kidney function, C-reactive protein, and IL-6; imaging data included chest CT scan; and, finally, treatment data included oxygen therapy, antiviral therapies, steroids, and heparin. The TSUNAMI national study (TranSfUsion of coNvalescent plAsma for the treatment of severe pneuMonIa due to SARS-CoV2) is an open-label randomized controlled multicentre study promoted by Agenzia Italiana del Farmaco (AIFA -Italian Medicines Agency), Istituto Superiore di Sanità (ISS Istituto Superiore di Sanità) and coordinated by AIFA, ISS, and Foundation GIMEMA, Italy. The main plasma donor eligibility criteria are age 18-65 years, molecular or serological COVID-19 diagnosis, male gender or nulliparous female, no previous transfusion, and neutralizing Ab titer ≥1:160. Evaluation of anti-SARS-CoV-2 IgG/IgM Abs was performed by the Clinical Pathology Unit of the Regina Elena National Cancer Institute (IRE). Blood samples were collected and separated by centrifugation at 2000 g for 20 min within 2 h of collection. The presence of IgG and IgM antibodies directed against both spike and nucleocapsid SARS-Cov-2 proteins was assessed by the MAGLUMI 2019-nCoV IgG and IgM chemiluminescence immunoassays on the fully automated MAGLUMI analyzer (SNIBE -Shenzhen New Industries Biomedical Engineering Co., Ltd, Shenzhen, China). The cut-off value was set at 1.0 AU/ml for both IgG and IgM; the overall reproducibility, declared by the manufacturer, ranged between 6.8% and 8.7%. Two parallel methods were used to assess the serum NT: The gold standard SARS-CoV-2 Micro Neutralization Test (MNT) and the indirect RABI test. The first method, implying the manipulation of hazardous viral stocks under highly demanding biosafety level 3 procedures and facilities, was performed at the INMI, the national referral laboratory for the TSUNAMI study. Serum samples were heat-inactivated at 56°C for 30 min and titrated in duplicate in seven twofold serial dilutions (starting dilution 1:10). Equal volumes of serum dilution and medium containing 100 TCID 50 SARS-CoV-2 (strain: SARS-CoV-2/human/ITA/PAVIA10734/2020 obtained from European Virus Archive -Global [EVAg]) were mixed and incubated at 37°C for 30 min. Subsequently, sub-confluent Vero E6 cell monolayers were challenged with the virus-serum mixtures and incubated at 37°C in a 5% CO 2 atmosphere. To standardize inter-assay procedures, high and low positive control (1:160 and 1:40 neutralizing activity, respectively) were included in each assay session. After 48 h, monolayers were scored for viral cytopathic effect by visual inspection under a low magnification light microscope. The highest serum dilution inhibiting at least 90% of the cytopathic effect was indicated as the MNT 90 . The latter RABI test actually measures the interaction of the RBD of the Spike 1 protein with the cell receptor protein ACE2, a critical and limiting step in viral entry. Although representing an indirect surrogate index of viral infection, this method permits the rapid and convenient evaluation of neutralizing Abs in lowlevel biological containment environments, such as field activity, first-level clinical pathology settings, and outpatient clinics, where most patients with COVID-19 are likely to be cared for. For this purpose, the COVID-19 Spike-ACE2 Binding Assay Kit (Raybiotech Life, Inc., GA, USA.) was used. Briefly, serum serial dilutions ranging from 1:16 to 1:2048 were prepared in a final 100 µl volume containing a fixed amount of a standard ACE2 protein and loaded, in duplicate, onto an RBD-coated 96-multiwell plate. After overnight incubation at 4°C, the plate was rinsed four-times with 300 µl of washing buffer and challenged with goat anti-ACE2 Ab. After 1 h of incubation at 25°C, the plate was decanted, washed as above, and loaded with anti-goat horseradish peroxidase conjugate-Ab for 1 h at 25°C. The plate was then washed again as above and challenged with 100 µl of peroxidase substrate 3,3',5,5'-tetramethylbenzidine, and after 40 min at room temperature for color development, the reaction was then stopped with 50 µl of 2.0 M sulphuric acid. The amount of reduced 3,3',5,5'-tetramethylbenzidine was then evaluated by the A 450 /A 620 measured by a Thermo Scientific Multiskan FC (Fisher Scientific Italia, Rodano, Italy). The total NT was then expressed as the reciprocal of the highest dilution yielding a 50% inhibition of ACE2/RBD binding activity (IC 50 ) compared with the titer of the negative control, here represented by a pool of six human sera collected before April 2019. Nonlinear sigmoidal standard curve interpolation (Prism 6.0 GraphPad Software, Inc. San Diego CA) was used to assign titers to sera dilutions with OD + SD, which did not match with the one of IC 50 . Specific anti-SARS-CoV-2 (COVID-19) Spike 1 IgA antibodies were assayed by the ELISA assay with the Human Anti-SARS-CoV-2 Virus (COVID-19) Spike 1 IgA Kit, provided by Alpha Diagnostic International (TX, USA) and used according to the supplier's instructions. IgA titers were expressed as the reciprocal of the highest serum dilution yielding OD in the range of the internal positive control 1 plus two SDs. Non-linear sigmoidal interpolation to the internal standard curve was used to calculate the final titers of samples with OD values outside the abovementioned range. Assay sessions were only validated provided both negative control (as above) and reaction blank OD values plus two SDs ranged below 20% of the internal positive control. A 51-year-old man presented to the first aid emergency ward of University Hospital "A. Gemelli" in Rome (Italy) complaining of a fever (up to 39°C), dry cough, and progressive dyspnoea for 10 days. The patient had been administered a pharmacological treatment with antipyretics and clarithromycin 500 mg twice a daily, which remained without success and had tested positive to a PCR COVID-19 test. The patient had not traveled recently but had been in contact with two known SARS-CoV-2-positive patients (father and sister). On presentation, his body temperature was 37.4°C, blood pressure 130/70 mmHg, heart rate 82 bpm, respiratory rate 20 breaths/min, and oxygen saturation 88% on room air. The admission chest CT showed bilateral interstitial pneumonia without thromboembolic complications. The patient was administered a 15-day treatment with Prezista/ritonavir and hydroxychloroquine. He also received oxygen therapy with a Venturi mask 28% and prophylaxis with low-molecular-weight heparin. Following two SARS-Cov-2 RT-PCR-negative nasopharyngeal swabs, collected on days 18 and 21 after admission, the patient was dismissed and followed-up at home. Three weeks after the second negative viral test, the convalescent COVID-19 patient was invited by the Immuno-Hematology and Transfusion Unit of Regina Elena Institute (Rome, Italy) to participate to the TSUNAMI national study and was found to fulfill the recruitment criteria for the TSUNAMI study and blood quality and safety according to the Italian Ministerial Decree of November 2, 2015. Upon enrolment, the donor tested positive for anti-S + anti-N serum IgG with a titer of 82.86 AU/ml ( Figure 1A) , tested negative for IgM (i.e., 0.95 AU/ml), and had a 90% micro-NT (MNT 90 ) of 1:320 ( Table 2 and Figure 1B) . Plasma was collected with a discontinuous flow cell separator, Haemonetics multicomponent collection system +, the volume of collected plasma was 600 ml, and each of the collected units was virus inactivated, aliquoted into three bags of 200 ml, frozen, and stored at the Immuno-Hematology and Transfusion Unit of San Camillo-Forlanini Hospital in Rome. IgG, IgM, and MNT 90 tests were repeated regularly and, thanks to the persistently high MNT 90 , the donor remained eligible for CP donation up to 155 days since enrolment. Throughout this period, in compliance with European recommendations and with his physical and medical condition (i.e., vascular accesses, plasma total proteins, and coagulation parameters), the donor underwent four successive plasma collections ( Table 2) . In Figure 2A , the titers of anti-SARS-CoV-2 IgA, IgG, IgM, and neutralizing Abs (RABI) are superimposed to those of MNT. In agreement with data reported on the kinetics of serological response (15, 16) , the anti-SARS-Cov-2 IgG titer steadily decreased from the initial 82.86 AU/ml down to 15.27 AU, while IgM was undetectable at any time point throughout the 155-day observation period. Conversely, the MNT 90 remained stable. As a matter of fact, a twofold decrease in MNT 90 was recorded from 6 May to 21 July 2020. Such a variation, however, remained isolated, and considering that at least a fourfold variation is needed for a dilution-based titer to be accepted as significant, it has to be regarded as a meaningless/irrelevant nominal fluctuation. Subsequently, a minor drop of MNT 90 titer occurred during the period between 21 July and 21 September 2020. As observed, there is no evident correlation between the steadily decreasing total IgG titer ("xs" on Figure 2 ) and the even level of MNT (solid squares on Figures 2A, B) , indicating that RBD-targeted antibodies (i.e., those relevant to suppression of viral transmission and sterilizing immunity) may have different kinetics and longer persistence than those targeted to non-RBD epitopes. Such divergent kinetics have already been reported (15) (16) (17) , and although no conclusive explanation has been proposed so far, it has to be considered in the enrolment and management of plasma donors. Interestingly, the curve of the RABI test (open squares, Figure 2C ) closely follows that of MNT, thus confirming the high neutralizing activity of the donor serum at any time point. Moreover, these results indicate that the RABI assay may represent a rapid and convenient surrogate test for the hazardous, labor-intensive, time-demanding MNT assay. Anti-S1 IgA also showed a time-related progressive decrease. However, their titer, once again, closely matched the profile as obtained both by MNT and RABI test, suggesting that IgA may be a relevant contributor to the neutralizing activity (Figures 2A, C) . Accordingly, their quantitative evaluation may represent an independent index of clinical evolution and outcome. On 10 June 2020, because an intercurrent oropharyngeal/ nasopharyngeal molecular swab tested positive for SARS-CoV-2 RNA by RT-PCR, plasma donation was temporarily suspended and then re-considered upon two successive negative swabs carried out 7 and 9 days later. As demonstrated in Figure 1 , this molecular positivity was not associated with a change in the trend of decline of total IgG or with a boost in NT. Re-infection is a common event with most viral airway diseases. A few clinically evident cases have been exceptionally documented for patients with COVID-19 (18) and a persistent viral positivity has been reported for a minority of cases (16, 17) , although its pathological meaning remains to be debated. In the case of our CCP donor, due to the lack of availability of the swabs collected from the initial COVID-19 infection, it was not possible to carry out comparative RNA sequencing to ascertain that there was a true re-infection. Nonetheless, the lack of increase in any of the measured antibody titer suggests that this was either a falsepositive result or that a putative re-infection was rapidly resolved with no impact on the immune response (19) . Five male patients with COVID-19 (age range: 46-73 years) were admitted to "L. Spallanzani" National Institute for Infectious Diseases, Rome, Italy, diagnosed with COVID-19, and transfused with the plasma from the above-mentioned donor. The median time from symptom onset to hospital admission was 6 days (range: 5-7 days). The Sequential Organ Failure Assessment (SOFA) score at admission was between 3 and 4. Four patients (namely, patients 1, 3, 4, and 5) had no comorbidity, and three (patients 1, 2, and 3) were overweight with a BMI between 27 and 29. All patients received subcutaneous low-molecular-weight heparin; this was a prophylactic intervention in two cases and therapeutic treatment in three cases (the latter ones received concomitant intravenous methylprednisolone 0.5 mg/kg); three patients received intravenous remdesivir 200 mg on day 1 followed by 100 mg daily on days 2-5. The patients received CP transfusion 7-26 days (median: 13) after symptom onset. The SOFA score was 5-7 immediately before transfusion and reduced, showing improvement, in two out of five patients after transfusion (patients 2 and 3) (Supplementary Figure 1A) . The PaO 2 /FiO 2 ratio ranged from 92 to 294 at admission, and from 172 to 182 immediately before CP treatment; they improved after CP transfusion for all patients (Supplementary Figure 1B) . Lymphocytopenia improved after CP transfusion in four of the five patients (Supplementary Figure 1C) . All patients presented bilateral ground-glass opacity and/or pulmonary parenchymal consolidation (on the chest CT scan), and two of them were carrying pulmonary micro-embolism immediately before CP transfusion (Supplementary Figure 2) . After the transfusion, the pulmonary lesions in two patients (patients 2 and 4) markedly reduced (Supplementary Figures 1A, 3B) , while the remaining patients (patients 1, 3 and 5) had no significant improvement. During CP treatment, patients 1, 2, and 4 were on non-invasive ventilation, whereas patients 3 and 5 were on mechanical ventilation. Four patients (patients 1, 2, 3, and 5) had infectious complications and three of them eventually died due to sepsis (patients 1, 3, and 5) and never exhibited negative SARS-CoV-2 RNA, assayed by RT-PCR. Patient 2 was discharged after 31 days of hospitalization, and patient 4 after 33 days. Here, we report evidence of the long-term persistence of hightiter viral-neutralizing Abs in a convalescent COVID-19 plasma donor. Although the total IgG titer steadily declined, neutralizing Abs measured by both MNT 90 and RABI methods persisted at high neutralization titers for up to 155 days in the donor serum. Divergent kinetics between RBD-targeted and total anti-Abs have already been reported (15) (16) (17) , and although no conclusive explanation has been proposed so far, it has to be considered in the enrolment and management of plasma donors. In light of these results, we can conclude that the anti-S/anti-N IgG test, which was originally devised to achieve the highest sensitivity in the screening of patients and asymptomatic carriers, appears not suited for patient follow-up and immunity surveillance. Interestingly, the surrogate RABI test readouts were in agreement with those generated by the gold standard MNT method. Thus, the RABI assay may represent a rapid and convenient surrogate for the hazardous, laborintensive, time and technically demanding MNT test. This is particularly relevant in primary-level hospitals and care institutions devoid of biosafety level 3 facilities, where most COVID-19 patients are expected to be cared for. Our data point to a possible relevant role of IgA in the COVID-19 immune response. Actually, serum anti-S1 IgA levels showed a (20) showing that IgA from COVID convalescent patients had a stronger competitive capacity and a much higher specific neutralizing potency than IgG and IgM and suggests that anti-S1 IgA titer, at least in a part of cases, may be an independent serological index for patients evaluation and follow-up (20) . Conversely, our finding is not consistent with recently published data showing a quick decay of IgA titers in CP donors (21) . We have no hypothesis to propose for these conflicting data; however, a marked heterogeneity in immune response has been reported in the general population and among different CP donors (22, 23) . Moreover, we recorded an extended IgA persistence at least in a part of other convalescent patients indicating that, at the present state of knowledge, no general rule response can be proposed to predict an outcome of each particular case, thus warranting detailed surveillance in potential plasma donors. Nearly 3 months after the full symptomatic resolution, the donor tested positive for SARS-CoV-2 RNA. Such a finding is not unusual (17) , and a number of explanations can be hypothesized besides re-infection. According to the WHO, a positive RT-PCR molecular test in the absence of new symptoms up to 100 days after the onset of the first infection is not considered reinfection, but a rather long shedding possibly involving non-viable virus, defective viral/sub-viral particles, non-infectious viral/sub-viral genomes, and viral/sub-viral subunits engulfed in phagocytic or immune cells. Available data do not allow to clarify this point. In order to overcome the current CCP shortage (23), regulatory agencies have reduced the interval otherwise required for standard plasmapheresis donations (24, 25) . In line with these guidelines, we performed plasmapheresis at minimum 15-day intervals. We observed that high NTs can persist for up to 155 days and probably longer, thus allowing for multiple donations carrying the opportunity to overcome the present CCP shortage. In conclusion, a COVID-19 CP donor presented persistently high neutralizing anti-SARS-CoV-2 Abs, which definitely improved the clinical conditions of five patients with severe COVID-19. The impact of reported findings is limited in that they are derived from a single patient serving as a plasma donor. Nonetheless, this case highlights several potentially interesting data. (i) At least in some cases, CCP can maintain neutralizing activity for a considerable time. Indeed, a comparable persistence of high RABI titers has been observed in a number of other cases, although ultimately not eligible for plasma donation (Supplementary Figure 3) , thus suggesting that close monitoring is needed for precious plasma donors. (ii) CCP from a single donor improved the clinical conditions of five severely ill patients with COVID-19, pointing to a rather consistent therapeutic profile. Moreover, CCP, because of its polyclonal nature, is intrinsically resilient to RBD mutation, while the efficacy of monoclonal Abs may be dramatically reduced against the currently emerging viral variants (26) . Thus, plasma super-donors may soundly contribute to relieving the current shortage of CCP. (iii) RABI may provide a rapid and convenient alternative to the highly hazardous, labor-intensive, viral neutralization test. (iv) IgA titer may represent an independent serological index for the evaluation and follow-up of patients. The original contributions presented in the study are included in the article/Supplementary Material. Raw data are available at https://gbox.garr.it/garrbox/index.php/s/TTyNW88trUVuWVz. Ethical review and approval was not required for the study on human participants in accordance with the local legislation and institutional requirements. The patients/participants provided their written informed consent to participate in this study. Writing-original draft preparation. GC, FM, MR, and MF. Writing-review and editing: FM, MR, and GM. CT images: AC, DD, SIan, SIab, and LM. Graphs: FM and MR. Supervision: GC and FM. GP and FM equally contributed to this work. All authors contributed to the article and approved the submitted version. The study was supported by funds from the Italian Ministry of Health, Ricerca Corrente. A New Coronavirus Associated With Human Respiratory Disease in China SARS-CoV-2 Vaccines in Development REGN-COV2 Antibodies Prevent and Treat SARSCoV-2 Infection in Rhesus Macaques and Hamsters Convalescent Plasma or Hyperimmune Immunoglobulin for People With COVID-19: A Living Systematic Review REGN-COV2, a Neutralizing Antibody Cocktail, in Outpatients With COVID-19 Recent Advances in Antibody-Based Immunotherapy Strategies for COVID-19 Tackling COVID-19 With Neutralizing Monoclonal Antibodies Serological Approaches for COVID-19: Epidemiologic Perspective on Surveillance and Control Performance Assessment of 11 Commercial Serological Tests for SARS-CoV-2 on Hospitalized COVID-19 Patients Clinical Validation of a Second Generation Anti-SARS-CoV-2 IgG and IgM Automated Chemiluminescent Immunoassay A Novel in-Cell ELISA Assay Allows Rapid and Automated Quantification of SARS-CoV-2 to Analyze Neutralizing Antibodies and Antiviral Compounds Comparative Performance of Five Commercially Available Serologic Assays to Detect Antibodies to SARS-CoV-2 and Identify Individuals With High Neutralizing Titers Sensitivity of Anti-SARS-CoV-2 Serological Assays in a High-Prevalence Setting Kinetics of Viral Load and Antibody Response in Relation to COVID-19 Severity Viral and Antibody Kinetics of COVID-19 Patients With Different Disease Severities in Acute and Convalescent Phases: A 6-Month Follow-Up Study Humoral Response and PCR Positivity in Patients With COVID-19 in the New York City Region, USA: An Observational Study COVID-19 Re-Infection by a Phylogenetically Distinct SARS-Coronavirus-2 Strain Confirmed by Whole Genome Sequencing Persistent Positivity and Fluctuations of SARS-CoV-2 RNA in Clinically-Recovered COVID-19 Patients Characterization of SARS-CoV-2-Specific Antibodies in COVID-19 Patients Reveals Highly Potent Neutralizing IgA Persistence of SARS-CoV-2 Specific B-and T-Cell Responses in Convalescent COVID-19 Patients 6-8 Months After the Infection Age, and Hospitalization Drive Antibody Responses in a COVID-19 Convalescent Plasma Donor Population SARS-CoV-2 Specific Antibody and Neutralization Assays Reveal the Wide Range of the Humoral Immune Response to Virus An EU Programme of COVID-19 Convalescent Plasma Collection and Transfusion The Effect of Spike Mutations on SARS-CoV-2 Neutralization Conflict of Interest: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest Editorial assistance was provided by Laura Brogelli, PhD, and Aashni Shah (Polistudium SRL, Milan, Italy).